Loading...
HomeMy WebLinkAboutNCG100034_MONITORING INFO_20190301 (2)STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. �v DOC TYPE El HISTORICAL FILE MONITORING REPORTS DOC DATE ❑ O'101 q a3 D YYYYMMDD Stormwater Discharge Monitoring Report for North Carolina Division of Energy, Mineral and Land Resources General Permit No. NCG100000 Date submitted CERTIFICATE OF COVERAGE No. NCG10 0 0 3 4 SAMPLE COLLECTION YEAR 2019 FACILITY NAME LKQ City Auto Salvage ( �� SAMPLE PERIOD ❑ Jan -June ❑ July -Dec COUNTY Durham or 0 Monthly' January _ (month) PERSON COLLECTING SAMPLES Bryan Woody MAR D 1 2019 DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA LABORATORY TestAmerica Lab Nashville Lab Cert. # 490 ❑Zero -flow ❑Water Supply ❑SA FILES Comments on sample collection or analysis: EN 1 —L [:]Other None SECTION PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 Part A: Stormwater Benchmarks and Monitoring Results Total event rainfall' or No discharge this pe�riod?6 4 outfall .No. Date . Sam le p Collected, mo/dd/year pH, Standard Units Total Suspended Solids (TSS), m L Non -polar O&G/TPH (Methad�1664 SGT=HEM), mg/L Ethylene Glycol,. mg/L Lead, Total Recoverable, m L Total Toxic g Organics , mg/L New Motor or Hydraulic Oil Usage, gal/mo Benchmark - 6.0 — 9.01 100 ar 50Z 15 8;000 (Tier3.21and.3) 0.075 1.0 IParamete Cody - W0-04001W 1=t65301111M 00552 77023, �01051 NW78141� EWNCO.IL Outfall 001 January 2019 <5-gallons Note: If you report a sampled value in excess of the benchmark value, or outside the benchmark range for pH, you must implement Tier 1 or Tier 2 responses in the General Permit. 'If pH values outside this range are recorded in sampled stormwater discharges, but ambient precipitation pH levels are lower, then the lower threshold of this benchmark range is the pH of the precipitation (within instrument accuracy) instead of 6 S.U. Readings from an on -site or local rain gauge (or local precipitation data) must be documented to demonstrate background concentrations were below the benchmark pH range of 6-9. ZSee General Permit Table 1, identifying the especially sensitive receiving waters classifications where the more protective benchmark applies. 3For purposes of this permit the definition of Total Toxic Organics is that list as stated in Appendix D, Table 11 of Chapter 40 Code of Federal Regulations (CFR) Part 122. 'Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. sTotal precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 6For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. Permit Date: 11/1/2018-05/31/2021 Form SWU-251, Last Revised 11/1/2018 Page 1 of 2 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may request that DEMLR waive monitoring of total toxic organics. The solvent management plan shall include a list of the total toxic organic compounds used along with other requirements listed in the General Permit. For those facilities allowed such a waiver, the discharger shall sign the following certification statement: Solvent Management Plan Certification Statement "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics po), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Name (Print ame)-- ez 4k- -�— AA Title (Print title) Signature Date Mail Original to: Division of Water Quality Attn: Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." Signature of Permittee Permit Date:11/1/2018-05/31/2021 -;� -a Date Form SWU-251, Last Revised 11/1/2018 Page 2 of 2 I I i i CERTIFIED MAIL, RETURN' RECEIPT REQUESTED Date: i I! Division of Water Quality , i I'�. RECEIVED- Attn: Central Files I i OCT2 5 2018 1617 Mail Service Center, i Raleigh. North Carolina 27699-1617 CENTRAL FILES ! DWR SECTION RE: LKQ City Auto''Salvage Durham, NC Permit # NCG 10634 I Stormwater Discharge Outfall Monitoring Report - Tier Two Response Dear Sir/Madam'I l' Please find attached the Stormwater Discharge Outfall (SDO) Monitoring Report for the LKQ I City Auto Salvage facility located in Durham, North Carolina. This submittal covers the seventh monthly monitoring period (September'2018) of the Tier Two response. No discharge occurred during the September- monitoring period. Please call me at 252-474-7819 or Mr. Samuel Svoboda of RPS at 404-809- 3861 if you have any comments, questions. or concerns about the information presented in this submittal. Sincerely. i Bryan Woody Plant Manager Attachment I STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT CERTIFICATE OF F COVERAGE NO. NCG100034 SAMPLES COLLECTED DURING CALENDAR YEAR: 2018 (this monitoring reporf shall be received"by the`Division no later than 30 days from the date the facility receives the sampling results from the laboratory.) FACILITY'NAME-LKQ City -Auto, Salvage --COUNT-Y-Durham PERSON COLLECTING SAMPLE(S) N/A PHONE NO. (252) 474-7819 CERTIFIED LABORATORY(S) NIA Lab N/A PLEASE REMEMBER TO SIGN ON THE REVERSE —Part-, is tormwater Benchmarks and Monitoring Results--`- -- Far sampling periods with no discharge, you must submit this discharge monitoring form noting "No Flow" or "No Discharge" within _ 30 days of the end of that period to comply with permit reporting requirements. Outfail No. Date Sample Collected, mo/dd/year Total Rainfall, inches 00400 00530 - - - - 77023 01051 78141 pH, Standard Units Total Suspended Solids (TSS), mg/L Non -polar O&G/TPH (Method 1664 SGT-HEM), mg/L Ethylene Glycol, mg/L Lead, Total Recoverable, mg/L Total Toxic Organics3, mg/L Benchmark 6.0 — 9.01 100/50, 15 8,000 (Tiers 2 and 3) 0.03 1.0 Outfall 001 September 2018 NO DISCHARGE THIS PERIOD Note: If you report a sampled value in excess of the benchmark value, or outside the benchmark range for pH, you must implement Mier 1 or Tier 2 responses in the General Permit. 1See If pl-I values outside this range are recorded in sampled stormwater discharges, but ambient precipitation pH levels are lower, then the lower threshold of this benchmark range is the pH of the precipitation (within instrument accuracy) instead of 6 S.U. Readings from an on -site or local rain gauge (or local precipitation data) must be documented to demonstrate background concentrations were below the benchmark pH range of 6-9- 2See General Permit text to identify whether the more protective benchmark applies for especially sensitive receiving waters. 3For purposes of this permit the definition of Total Toxic: Organics is that list as stated in Appendix D, Table II of Chapter 40 Code of Federal Regulations (CFR) Part 122. Morns SWU-251, lost revised Oclober 2.5, 2072 Pape 1 u1 2 STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may request that DWQ waive monitoring of total toxic organics. l'he solvent management plan shall include a list of the -total toxic organic compounds used and the other elements iisted•in the General Permit. I -or those facilities allowed such a waiver, the discharger shall sign the following certification statement: ment Plun Certification: Statement "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing all the provisions of the solvent management plan included in the Stormwater Pollution PFe_ e6Ttion Plan:" -"- ` - - - -- Name Pint na e) Kagde Title (Print titl Signature Date Mail Original and one copy to: Division of Water Quality Attn: Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. eased on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there a v_&irpificant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee or Designee) WWI IS - (Date) Burro 5WU-251, last r'rtvisedOctober 25, 2032 5-TORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT CERTIFICATE OF COVERAGE NO. NCGIO0034 SAMPLES COLLECTED DURING CALENDAR YEAR: 2018 (This monitoring report shall -be -received by the -Division no later than 30 days from the date the facility receives the sampling results from the laboratory.) FACILITY NAME'LKQ-City-Auto-Salvage COUNT-Y-Durham—_ PERSON COLLECTING SAMPLE(S) N A PHONE NO. 252 474-7819 CERTIFIED LABORATORY(S) N/A Lab N A PLEASE REMEMBER TO SIGN ON THE REVERSE - -Part-A: Stormwater Benchmarks For sampling periods with no discharge, you must submit this discharge monitoring form noting "No Flow" or "No Discharge" within 30 days of the end -of that period to -comply with permit reporting requirements. Outfall No. Date Sample Collected, mo/dd/year Total Rainfall, inches 00400 00530 ---- 77023 01051 78141 pH, Standard Units Total Suspended Solids (TSS), mg/L Non -polar O&G/TPH (Method 1664 SGT-HEM), mg/L Ethylene Glycol, mg/L Lead, Total Recoverable, mg/L Total Toxic Organics3, mg/L Benchmark 6.0-9.01 100/502 15 8,000 (Tiers 2 and 3) 0.03 1.0 Outfall 001 September 2018 O DISCHARGE THIS PERIOD Note: If you report a sampled value in excess of the benchmark value, or outside the benchmark range for pH, you must implement Tier 1 or Tier 2 responses in the General Perris k. 1See If pH values outside this range are recorded in sampled stormwater discharges, but ambient precipitation pH levels are lower, then the lower threshold of this benchmark range is the pH of the precipitation (within instrument accuracy) instead of 6 S,(J, Readings from an on -site or local rain gauge (or local precipitation data) must he documented to demonstrate background concentrations were below the benchmark pH range of 6-9. 2See General Permit text to identify whether the more protective benchmark applies for especially sensitive receiving waters. )For Purposes of (his permit the definition of Dotal Toxic: Organics is Lhat lost as stated in Appendix D, Table II of Chapter 40 Code of I-ederaI Regulmt ons (CFR) Fart 1-22 Forni SWU-2S 1, Kist revised October2.5, 200 vage 1_ of I STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may request that DWQ waive monitoring of total toxic organics. The solvent management plan sfiall'include a list of the total toxic organic compounds used -and the other -elements listed in the General Permit. For those facilities allowed such a waiver, the discharger shall sign the following certification statement: Solvent Management Plan Certification Statement "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the Stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing all the provisions of the solvent management plan included in the Stormwater Pollution Preention Name (Print name) Title (Print title signature Mail Original and one copy to: Division of Water Quality Attn: Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Date "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted.. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. 1 am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Pei nittee or kignee) ( Date) Form SWtj-251, last revised Octofu,r25, ;4112 Page 2 of 2 r CERTIFIED MAIL, RETURN RECEIPT REQUESTED Division of Water Quality Attn: Central Files 1617 Mail Service Center RECEIVED Raleigh; North Carolina 27699-1617 '"` AUG 2 2 2018 RE: LKQ City Auto Salvage CENTRAL Durham, NC CENTRALFILES Permit # NCG100034 dWR SECTION Stormwater Discharge Outfall Monitoring Report - Tier Two Response Dear &r/Madam: Please find attached the Stormwater Discharge Outfall (SDO) Monitoring Report for the LKQ City Auto Salvage facility located in Durham, North Carolina. This submittal covers the fifth monthly monitoring period (July 2018) of the Tier Two response. No Discharge occurred during the July monitoring period. Please call me at 252-474-7819 or Mr. Seth Aiffl of RPS at 404-809-3877 if you have any comments, questions, or concerns about the information presented in this submittal. Sincerely, Bryan Woody Plant Manager Attachment CERTIFICATE OF COVERAGE NO. NCG100034 FACILITY NAME LKQ City Auto Salvage PERSON COLLECTING SAMPLE(S) N/A CERTIFIED LABORATORY(S) N/A Lab N/A Part A: Stormwater Benchmarks and Monitoring Results STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT SAMPLES COLLECTED DURING CALENDAR YEAR: 2018 (This monitoring report shall be received by the Division no later than 30 days from the date the facility receives the sampling results from the laboratory.) COUNTY Durham PHONE NO. (252) 474-7819 PLEASE REMEMBER TO SIGN ON THE REVERSE 4 For sampling periods with no discharge, you must submit this discharge monitoring form noting "No How" or "No Discharge" within 30 days of the end of that period to comply with permit reporting requirements. Outfall No. Date Sample Collected, mo/dd/year Total Rainfall, inches 00400 00530 ---- 77023 01051 78141 pH, Standard Units Total Suspended Solids (TSS), mg/L Non -polar O&G/TPH (Method 1664 SGT-HEM), mg/L Ethylene Glycol, mg/L Lead, Total Recoverable, mg/L Total Toxic Organics3, mg/L Benchmark - 6.0 — 9.01 100/502 15 8,000 (Tiers 2 and 3) 0.03 1.0 Outfall 001 July 2018 O DISCHARGE THIS PERIOD Note: If you report a sampled value in excess of the benchmark value, or outside the benchmark range for pH, you must implement Tier 1 or Tier 2 responses in the General Permit. 1See If pH values outside this range are recorded in sampled stormwater discharges, but ambient precipitation pH levels are lower, then the lower threshold of this benchmark range is the pH of the precipitation (within instrument accuracy) instead of 6 S.U. Readings from an on -site or local rain gauge (or local precipitation data) must he documented to demonstrate background concentrations were below the benchmark pH range of 6-9. 2See General Permit text to identify whether the more protective benchmark applies for especially sensitive receiving watars, 3For purposes of this permit the definition of Total Toxic Organics is that list as stated in Appendix D, Table II of Chapter 40 Code of Federal Regulations (CFR) Part 122. Form SWU-251, lust revised October 25, 2012 Page 1. of 2 STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may request that DWQ waive monitoring of total toxic organics. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed_ in the General Permit. For those facilities allowed such a waiver, the discharger shall sign the following certification statement: Solvent Management Plan Certification Statement "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing all the provisions of the solvent management plan included in the Stormwater Pollutjoy Prevention Plan." Signature Mail Original and one copy to: Division of Water Quality Attn: Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Date "I certify, under penalty of law, that thi$ document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee or Designee) Vlrc (Date) Form SWU-251, last revised October25, 2012 Page 2 of 2 STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT CERTIFICATE OF COVERAGE NO. NCG100034 FACILITY NAME LKQ City Auto Salvage PERSON COLLECTING SAMPLE(S) Bryan Woody CERTIFIED LABORATORY(S) Test America Lab Nashville Lab##490 Part A: Stormwater Benchmarks and Monitoring Results t SAMPLES COLLECTED DURING CALENDAR YEAR: 2018 (This monitoring report shall be received by the Division no later than 30 days from the date the facility receives the sampling results from the laboratory.) REe=I V ED AUG 22 2018 CENTRAL FILES DWR SECTION COUNTY Durham PHONE NO. (252) 474-7819 PLEASE REMEMBER TO SIGN ON THE REVERSE 4 For sampling periods with no discharge, you must submit this discharge monitoring form noting "No Flow" or "No Discharge" within 30 days of the end of that period to comply with permit reporting requirements. Outfall No. Date Sample Collected, mo/dd/year Total Rainfall, inches 00400 00530 - - - - 77023 01051 78141 pH, Standard Units Total Suspended Solids (TSS), mg/L Non -polar O&G/TPH (Method 1664 SGT-HEM), mg/L Ethylene Glycol, mg/L Lead, Total Recoverable, mg/L Total Toxic organics3, mg/L Benchmark - - 6.0 -- 9.01 100/502 1S 8,000 (Tiers 2 and 3) 0.03 1.0 Outfall 001 6/27/2018 0.74 7.0 46 <4.4 (Below Recordable Limit) <10 (Below Recordable Limit) 0.035 Exempt Note: If you report a sampled value in excess of the benchmark value, or outside the benchmark range for pH, you must implement Tier 1 or Tier 2 responses in the General Permit. 1See If pH values outside this range are recorded in sampled stormwater discharges, but ambient precipitation pH levels are lower, then the lower threshold of this benchmark range is the pH of the precipitation (within instrument accuracy) instead of 6 S.U. Readings from an on -site or local rain gauge (or local precipitation data) must be documented to demonstrate background concentrations were below the benchmark pH range of 6-9. 2See General Permit text to identify whether the more protective benchmark applies for especially sensitive receiving waters. 3For purposes of this permit the definition of Total Toxic Organics is that IisL as stated in Appendix D, Table II of Chapter 40 Code of Federal Regulations (CFR) Part 122. Form SWU-251, last revised October 25, 2012 Page 1 of 2 STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may request that DWQ waive monitoring of total toxic organics. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities allowed such a waiver, the discharger shall sign the following certification statement: Solvent Management Plan Certification Statement "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TT-0), certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the Stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan."n.� Name (Pri t name) Title (Print title) I� /Y cz- Signature Mail Original and one copy to: Division of Water Quality Attn: Central Files 1617 Mail Service Center North Carolina 27699-1617 "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee or Designee) `�l�l /1 <-: �-, (Date) Form SWU-251, last revised October 25, 2012 Page 2 of 2 CERTIFI-CATE OF COVERAGE NO. NCG100034 FACILITY NAME LKQ City Auto Salvage PERSON COLLECTING SAMPLE(S) N/A CERTIFIED LABORATORY(S) N/A Lab N A Part A: Stormwater Benchmarks and Monitoring Results STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT SAMPLES COLLECTED DURING CALENDAR YEAR: 2018 (This monitoring report shall be received by the Division no later than 30 days from the date the facility receives the sampling results from the laboratory.) COUNTY Durham PHONE NO. (252) 474-7819 PLEASE REMEMBER TO SIGN ON THE REVERSE 4 For sampling periods with no discharge, you must submit this discharge monitoring form noting "No Flow" or "No Discharge" within 30 days of the end of that period to comply with permit reporting requirements. Outfall No. Date Sample Collected, mo/dd/year Total Rainfall, inches OD400 00530 - - - - 77023 01051 78141 pH, Standard Units Total Suspended Solids (TSS), mg/L Non -polar O&G/TPH (Method 1664 SGT-HEM), mg/L Ethylene Glycol, mg/L Lead, Total Recoverable, mg/L Total Toxic 3 Organics , mg/L Benchmark - 7—F6.0-9.01 100/502 15 8,000 (Tiers 2 and 3) 0.03 1.0 Outfall 001 May 2018 ❑ NO DISCHARGE THIS PERIOD Note: If you report a sampled value in excess of the benchmark value, or outside the benchmark range for pH, you must implement Tier 1 or Tier 2 responses in the General Permit. 1See If pH values outside this range are recorded in sampled stormwater discharges, but ambient precipitation pH levels are lower, then the lower threshold of this benchmark range is the pH of the precipitation (within instrument accuracy) instead of 6 S.U. Readings from an on -site or local rain gauge (or local precipitation data) must be documented to demonstrate background concentrations were below the benchmark pH range of 6-9. 2See General Permit text to identify whether the more protective benchmark applies for especially sensitive receiving waters. 3For purposes of this permit the definition of Total Toxic Organics is that list as stated in Appendix D, Table II of Chapter 40 Code of Federal Regulations (CFR) Part 122. Form SW U-251, last revised October 25, 2012 Page 1 of 2 STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may request that DWQ waive monitoring of total toxic organics. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities allowed such a waiver, the discharger shall sign the following certification statement: Solvent Management Plan Certification Statement "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." h,,-,y4W Name Pint name) Title (Print title) / Signature Date Mail Original and one copy to: Division of Water Quality Attn: Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee or Designee) (Date) Form SWU-251, last revised October 25, 2012 Page 2 of 2 STORMWATER DISCHARGE OUTFAI.I. (SDO) MONITORING REPORT CERTIFICATE OF COVERAGE NO. NCGl00034 SAMPLES COLLECTED DURING CALENDAR YEAR: 2018 (This monitoring report shall be received by the Division no later than 30 days from the date the facility receives the sampling results from the laboratory.) FACILITY NAME LKQ City Auto Salvage COUNTY Durham PERSON COLLECTING SAMPLE(S) N/A PHONE NO. 252 474-7819 CERTIFIED LABORATORY(S) N A Lab N A MAY 3 7 2018 CENTRE FILES PLEASC REIVIEIVIRFIR, O SIGN ON t HE RFVI:RSE 3 Part A: Stormwater Benchmarks and Monitoring Results DWR SECTION For sampling periods with no discharge, you must submit this discharge monitoring form noting "No Flow" or "No Discharge" within 30 days of the end of that period to comply with permit reporting requirements. Outfall No. Date Sample Collected, mo/dd/year Total Rainfall, inches 00400 00530 ---- 77023 01051 78141 pH, Standard Units Total Suspended Solids (TSS), mg/L Non -polar O&G/TPH (Method 1664 SGT-HEM), mg/L Ethylene Glycol, mg/L Lead, Total Recoverable, mg/L Total Toxic Organics3, mg/L Benchmark 6.0 — 9.01 100/50Z 15 8,000 (Tiers 2 and 3} 0.03 1.0 Outfall 001 April 2018 NO DISCHARGE THIS PERIOD Note: If you report a sampled value in excess of the benchmark value, or outside the benchmark range for pH, you must implement Tier 1 or Tier 2 responses in the General Permit. TSee If pH values outside this range are recorded in sampled stormwater discharges, but ambient precipitation pH levels are lower, then the lower threshold of this benchmark range is the pH of the precipitation (within instrument accuracy) instead of 6 SAJ. Readings from an on -site or local rain gauge (or local precipitation d.rta) must be documented to dernonstrate background concentrations were below the benchmark FAH range of 6-9. 2See General Permit text to identify whether the more protective benchmark applies for especially sensitive receiving waters. jFor pm poses of this permit the definition of Total Toxic Org; hies is that list as slated in Appendix D, Table II of Chapter40 Code of Federal Re€;ulations (CM) Part 12.2. I'm in `1WI.I-"J.5"I, lust revi5od Oclob(!r25, 201Z Paf,c, -I of J STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT Facilities that incorporate a solvent management plan ir7to the Stormwater Pollution Prevention Plan may request that DWQ waive monitoring of total toxic organics. 'f he solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities allowed such a waiver, the discharger shall sign the following certification statement: Solvent Monogernent Ylon Certification Statement "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TT0), I certify that'to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or storrnwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing all the provisions of the solvent management plan included in the Stormwater Pollution Prevention %Plan" Ay ala." 'G V f/dd/ Name (Print na e) Title (Print title) Signature Mail Original and one copy to. Division of Water Quality Attn: Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Date "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am awarethat there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee or Designee) �/7 (Date) I�orIII SWU-2 ;'I., hrsl fovisotl Oclnl, fv 25, 1012. Page 2 of 7. F• CERTIFIED MAIL, RETURN RECEIPT REQUESTED Date: a Division of Water Quality Attn: Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 RE: LKQ City Auto Salvage Durham, NC Permit # NCG100034 Stormwater Discharge Outfall Monitoring Report - Tier Two Response Dear Sir/Madam: RECEIVED APR 2 4 2018 CENI'I`V1L FILES DWR SECTION Please find attached the Stormwater Discharge Outfall (SDO) Monitoring Report for the LKQ City Auto Salvage facility located in Durham, North Carolina. This submittal covers the second monthly monitoring period (March 2018) of the Tier Two response. No Discharge occurred during the March monitoring period. Please call me at 252-474- 7819 or Mr. Seth Ailiff of RPS at 404-809-3877 if you have any comments, questions, or concerns about the information presented in this submittal. Sincerely Bryan Woody Plant Manager Attachment CERTIFICATE OF COVERAGE NO. NCG100034 FACILITY NAME LK City Auto Salvage PERSON COLLECTING SAMPLE(S) N A CERTIFIED LABORATORY(S) N/A Lab N A Part A: Stormwater Benchmarks and Monitoring Results STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT SAMPLES COLLECTED DURING CALENDAR YEAR: 2018 (This monitoring report shall be received by the Division no later than 30 days from the date the facility receives the sampling results from the laboratory.) COUNTY Durham PHONE NO. (252) 474-7819 PLEASE REMEMBER TO SIGN ON THE REVERSE --) For sampling periods with no discharge, you must submit this discharge monitoring form noting "No Flow" or "No Discharge" within 30 days of the end of that period to comply with permit reporting requirements. Outfall No. Date Sample Collected, mo/dd/year Total Rainfall, inches 00400 00530 ---- 77023 01051 78141 pH, Standard Units Total Suspended Solids (TSS), mg/L Non -polar O&G/TPH (Method 1664 SGT-HEM), mg/L Ethylene Glycol, mg/L Lead, Total Recoverable, mg/L Total Toxic Organics3, mg/L Benchmark - - 6.0 — 9.01 100/50z 15 8,000 (Tiers 2 and 3) 0.03 1.0 Outfall 001 March 2018 OISCHARGE THIS PERIOD Note: If you report a sampled value in excess of the benchmark value, or outside the benchmark range for pH, you must implement Tier 1 or Tier 2 responses in the General Permit. 1See If pH values outside this range are recorded in sampled stormwater discharges, but ambient precipitation pH levels are lower, then the lower threshold of this benchmark range is the pH of the precipitation (within instrument accuracy) instead of 6 S.U. Readings from an on -site or local rain gauge (or local precipitation data) must be documented to demonstrate background concentrations were below the benchmark pH range of 6-9. 2See General Permit text to identify whether the more protective benchmark applies for especially sensitive receiving waters. 3For purposes of this permit the definition of Total Toxic Organics is that list as stated in Appendix D, Table II of Chapter 40 Code of Federal Regulations (CFR) Part 122. Form SWU-251, lost revised October25, 2012 Page 1 of 2 STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may request that DWQ waive monitoring of total toxic organics. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities allowed such a waiver, the discharger shall sign the following certification statement! Solvent Management Plan Certification Statement "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), i certify that to the hest of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan. Name {Print name Title {P ' Signature Mail Original and one copy to: Division of Water Quality Attw Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Y/,?-�z �/- a Date "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (signature of Permittee ro Designee) (Date) Form SW U-251, last revised October 25, 2012 Page 2 of 2 STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT CERTIFICATE OF COVERAGE NO. NCGI00034 RECEIVED SAMPLES COLLECTED DURING CALENDAR YEAR: 2018 APR 24 201B CENTRAL FILIW 7 FACILITY NAME LKQ City Auto Salvage DWR SECTION PERSON COLLECTING SAMPLE(S) Bryan Woody CERTIFIED LABORATORY(S) Test America Lab Nashville Lab##490 Part A: Stormwater Benchmarks and Monitoring Results (This monitoring report shall be received by the Division no later than 30 days from the date the facility receives the sampling results from the laboratory.) COUNTY Durham PHONE NO. 252 474-7819 PLEASE REMEMBER TO SIGN ON THE REVERSE -) For sampling periods with no discharge, you must submit this discharge monitoring form noting "No Flow" or "No Discharge" within 30 days of the end of that period to comply with permit reporting requirements. Outfall No. Date Sample Collected, mo/dd/year Total Rainfall, inches 00400 00530 - - - - 77023 01051 78141 pH, Standard Units Total Suspended Solids (TSS), mg/L Non -polar O&G/TPH (Method 1664 SGT-HEM), mg/L Ethylene Glycol, mg/L Lead, Total Recoverable, mg/L Total Toxic Organics3, mg/L Benchmark - - 6.0 — 9.01 100/50z 15 8,000 (Tiers 2 and 3) 0.03 1.0 Outfall 001 2/15/2018 1.14 7.0 27 1.7 <10 (Below Recordable Limit) 0.030 Exempt Note: If you report a sampled value in excess of the benchmark value, or outside the benchmark range for pH, you must implement Tier 1 or Tier 2 responses in the General Permit. 1See If pH values outside this range are recorded in sampled stormwater discharges, but ambient precipitation pH levels are lower, then the lower threshold of this benchmark range is the pH of the precipitation (within instrument accuracy) instead of 6 S.U. Readings from an on -site or local rain gauge (or local precipitation data) must be documented to demonstrate background concentrations were below the benchmark pH range of 6-9. 2See General Permit text to identify whether the more protective benchmark applies for especially sensitive receiving waters. 3For purposes of this permit the definition of Total Toxic Organics is that list as stated in Appendix D, Table II of Chapter 40 Code of Federal Regulations (CFR) Part 122. Form SWU-251, last revised October 25, 2012 Page 1 of 2 STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may request that DWQ waive monitoring of total toxic organics. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities allowed such a waiver, the discharger shall sign the following certification statement: Solvent Management Plan Certificotion Statement "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. i further certify that this facility is implementing all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan."( rdf?Cl Name (FIrint name) &-14G7nac� �•`� Title (Print title) Signature '�� Date Mail Original and one copy to: Division of Water Quality Attn: Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel property gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee or Designee) (Date) Form SWU-251, lost revised October 25, 2012 Page 2 of 2 CERTIFIED MAIL, RETURN RECEIPT REQUESTED Date: / L Division of Water Quality Attn: Central Files fl 1617 Mail Service Center MAC Raleigh, North Carolina 27699-1617 GENTRP L F1LE S DWR SECTION' RE: LKQ City Auto Salvage Durham, NC Permit # NCG100034 2018 First Semi -Annual Stormwater Discharge Outfall Monitoring Report Dear Sir/Madam: Please find attached the First Semi -Annual Stormwater Discharge Outfall (SDO) Monitoring Report for the LKQ City Auto Salvage facility located in Durham, North Carolina. This submittal covers the reporting period January 1s' to June 30t', 2018. Please call me at 252-474-7819 or Mr, Robert Aiken of RPS at 404-809-3869 it you have any comments, questions, or concerns about the information presented in this submittal. Sincerely, Bryan Woody Plant Manager Attachment STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT CERTIFICATE OF COVERAGE NO. NCG100034 FACILITY NAME LKQ City Auto Salvage PERSON COLLECTING SAMPLE(S) Bryan Woody CERTIFIED LABORATORY(S) Test America Lab Nashville Lab#490 Part A: Stormwater Benchmarks and Monitoring Results SAMPLES COLLECTED DURING CALENDAR YEAR: 2018 (This monitoring report shall be received by the Division no later than 30 days from the date the facility receives the sampling results from the laboratory.) COUNTY Durham PHONE NO. (252) 474-7819 PLEASE REMEMBER TO SIGN ON THE REVERSE 4 For sampling periods with no discharge, you must submit this discharge monitoring form noting "No Flow" or "No Discharge" within 30 days of the end of that period to comply with permit reporting requirements. Outfall No. Date Sample Collected, mo/dd/year Total Rainfall, inches 00400 00530 - - - 77023 01051 78141 - pH, Standard Units Total Suspended Solids (TSS), mg/L Non -polar O&G/TPH (Method 1664 SGT-HEM), mg/L Ethylene Glycol, mg/L Lead, Total. Recoverable, mg/L Total Toxic Organics3, mg/L ._ Benchmark - 6.0 — 9.01 100/502 15 8,000 (Tiers 2 and 3) n 0:03 1.0 Outfall001 1/24/2018 0.12 7.8 79 2.2 28 0.099 Exempt Note: If you report a sampled value in excess of the benchmark value, or outside the benchmark range for pH, you must implement Tier 1 or Tier 2 responses in the General Permit. 1See If pH values outside this range are recorded in sampled stormwater discharges, but ambient precipitation pH levels are lower, then the lower threshold of this benchmark range is the pH of the precipitation (within instrument accuracy) instead of 6 S.U. Readings from an on -site or local rain gauge (or local precipitation data) must be documented to demonstrate background concentrations were below the benchmark pH range of 6-9. 2See General Permit text to identify whether the more protective benchmark applies for especially sensitive receiving waters. 3For purposes of this permit the definition of Total Toxic Organics is that list as stated in Appendix D, Table II of Chapter 40 Code of Federal Regulations (CFR) Part 122. Form SWU-251, last revised October 25, 2012 Page 1 of 2 STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may request that DWQ waive monitoring of total toxic organics. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities allowed such a waiver, the discharger shall sign the following certification statement: Solvent Management Plan Certification Statement "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the Stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." f hl 1144 ad L Name (Vint name) Ida -14— k 4u Title (Print title) Signature Date Mail Original and one copy to: Division of Water Quality Attn: Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee or Designee) (Date) Form SWU-251, last revised October25, 2012 Page 2 of 2 THE LEADER IN ENVIRONMENTAL TESTING ANALYTICAL REPORT TestAmerica Laboratories, Inc. TestAmerica Nashville 2960 Foster Creighton Drive Nashville, TN 37204 Tel: (615)726-0177 TestAmerica ,lob ID: 490-145301-1 TestAmerica SDG: RPS Proj# NeedlSite# 41478 Client Project/Site: #1142 - LKQ Durham For: GaiaTech Inc. PO BOX 12621 Knoxville, Tennessee 37912 Attn: Seth Ailiff Authorized for release by: 21712018 11:17:34AM Jim Knapp, Project Manager II (630)758-0262 jim.knapp@testamericainc.com 'he test results in this report meet all 2003 NELAC and 2009 TNI requirements for accredited sarameters, exceptions are noted in this report. This report may not be reproduced except in full, and with written approval from the laboratory, For questions please contact the Project Manager it the e-mail address or telephone number listed on this page. -his report has been electronically signed and authorized by the signatory. Electronic signature is 7teoded to be the legally binding equivalent of a traditionally handwritten signature. results relate only to the items tested and the sample(s) as received by the laboratory. Client: GaiaTech Inc. Project/Site: #1142 - LKQ Durham TestAmerica Job ID: 490-145301-1 SDG: RPS Proj# Need/Site# 41478 Table of Contents Cover Page .............................................. Table of Contents ......................................... 2 Sample Summary ......................................... 3 Case Narrative ........................................... 4 Definitions ............................................... 5 Client Sample Results ...................................... 6 QC Sample Results ........................................ 7 QC Association ........................................... 9 Chronicle ................................................ 10 Method Summary ......................................... 11 Certification Summary ...................................... 12 Chain of Custody ......................................... 1 13 TestAmerica Nashville Page 2 of 15 2I712018 Sample Summary Client: GaiaTech Inc. TestAmerica Job ID: 490-145301-1 Project/Site: #1142 - LKQ Durham SDG: RPS Proj# Need/Site# 41478 Lab Sample ID Client Sample ID Matrix Collected Received 490-145301-1 #1142 LKQ Durham Water 01/24/18 11:30 01/25/18 09:15 TestAmerica Nashville Page 3 of 15 2/7/2018 Case Narrative Client: GaiaTech Inc. Project/Site: #1142 - LKQ Durham Job ID: 490-145301-1 Laboratory: TestAmerica Nashville Narrative TestAmerica Job ID: 490-145301-1 SDG: RPS Proj# NeedlSite# 41478 Job Narrative 490-145301-1 --� Comments No additional comments 1 Receipt S: The sample was received on 1/2512018 9:15 AM; the sample arrived in good condition, properly preserved and, where required, on ice. Lt�: The temperature of the cooler at receipt was 1.50 C. f— L:! Receipt Exceptions The following sample was received at the laboratory without a sample collection time documented on the chain of custody: #1142 LKQ z "` Durham (490-145301-1). Date and time off of containers GC Semi VOA No analytical or quality issues were noted, other than those described in the DefinitionslGlossary page. Metals Method(s) 200.7 Rev 4.4, 6010B, 6010C, 6010D: Method only requires the samples run for three burns and the internals meet the method criteria, therefore, data was reported. (CCB 490-492912128) and (ICSA 490-492912/12) No additional analytical or quality issues were noted, other than those described above or in the Definitions/Glossary page. General Chemistry No analytical or quality issues were noted, other than those described in the DefinitionslGlossary page. Organic Prep No analytical or quality issues were noted, other than those described in the Definitions/Glossary page. TestAmerica Nashville Page 4 of 15 2/7/2018 Definitions/Glossary I:. Client: GaiaTech Inc. TestAmerica Job ID: 490-145301-1 ,• -. Project/Site: #1142 - LKQ Durham SDG: RPS Proj# Need/Site# 41478 Qualifiers - ----- --- — - —-------- — - — — - -- — --- — , , General Chemistry �r Qualifier Qualifier Description J Result is less than the RL but greater than or equal to the MDL and the concentration is an approximate value. ?� Glossary Abbreviation These commonty used abbreviations may or may not be present in this report. c Listed under the "D" column to designate that the result is reported on a dry weight basis %R Percent Recovery CFL Contains Free Liquid CNF Contains No Free Liquid DER Duplicate Error Ratio (normalized absolute difference) l a� •� Dil Fac Dilution Factor DL Detection Limit (DoDIDOE) i- F'- DL, RA, RE, IN Indicates a Dilution, Re -analysis, Re -extraction, or additional Initial metals/anion analysis of the sample DLC Decision Level Concentration (Radiochemistry) EDL Estimated Detection Limit (Dioxin) LOD Limit of Detection (DoDIDOE) _ LOQ Limit of Quantitation (DoDIDOE) I MDA Minimum Detectable Activity (Radiochemistry) MDC Minimum Detectable Concentration (Radiochemistry) MDL Method Detection Limit ML Minimum Level (Dioxin) NC Not Calculated ND Not Detected at the reporting limit (or MDL or EDL if shown) PQL Practical Quantitation Limit QC Quality Control RER Relative Error Ratio (Radiochemistry) RL Reporting Limit or Requested Limit (Radiochemistry) RPD Relative Percent Difference, a measure of the relative difference between two points TEF Toxicity Equivalent Factor (Dioxin) TEQ Toxicity Equivalent Quotient (Dioxin) TestAmerica Nashville Page 5 of 15 217I2018 Client Sample Results Client: GaiaTech Inc. Project/Site: #1142 - LKQ Durham Client Sample ID: #1142 LKQ Durham T Date Collected: 01/24/18 11:30 Date Received: 01/25/18 09:15 Method: 8015C - Glycols- Direct Injection (GCIFID) TestAmerica Job ID: 490-145301-15-1 SDG: RPS Proj# Need/Site# 41478 Lab Sample ID: 490-145301-1 E '-�l Matrix: Water �T --- Fill Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac Ethylene glycol 28 10 1.0 mg1L _ 01/27/18 16:43 1 Surrogate %Recovery Qualifier Limits n-butyl alcohol (Surr) 102 70- 130 Method: 200.7 Rev 4.4 - Metals (ICP) - Total Recoverable Prepared Analyzed D7! Fac U. 01/27/18 16:43 1 I 1 Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac Lead 0.099 0.0050 0.0020 mg1L 0113011812:46 02101/1816:34 1 .1 I General Chemistry - Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac HEM 2.2 J 4.5 1.6 mglL 02106/1810:12 02106/1810:12 1 w Total Suspended Solids 79 4.0 2.8 mglL 01/26/18 22:00 1 Analyte Result Qualifier RL RL Unit D Prepared Analyzed Dil Fat -_ �pH 7.8 0.1 0.1 SU 0210111812:43 1 i E TestAmerica Nashville Page 6 of 15 2/712018 QC Sample Results Client: GaiaTech Inc. Project/Site: #1142 - LKQ Durham Method: $015C - Glycols- Direct Injection (GCIFID) Lab Sample ID: MB 490-49173015 Matrix: Water Analysis Batch: 491730 MB MB Analyte Result Qualifier RL MDL Unit Ethylene glycol <10 MB 1148 Surrogate %Recovery Qualifier n-butyl alcohol (Su(r) 103 Lab Sample ID: LCS 490-491730/6 Matrix: Water Analysis Batch: 491730 Analyto Ethylene glycol LCS LCS Surrogate %Recovery Qualifier n-butyl alcohol (Surr) 104 10 1.0 mglL Limits 70-130 TestAmerica ,lob ID: 490-145301-1 G.1A�—! SDG: RIPS Proj# Need/Site# 41478 Client Sample ID: Method Blank Prep Type: Total/NA Ell D Prepared Analyzed DO Fac — — 01/2711812:37 Prepared Analyzed Dil Fac 5-1 7118 12,37 1 Client Sample ID: Lab Control Sample Prep Type: Total/NA Spike LCS LCS %Rec. Added Result Qualifier Unit D %Rec Limits 50.0 49.4 mglL 99 70 - 130 Limits, 70. 130 Method: 200.7 Rev 4.4 - Metals (ICP) Lab Sample ID: MB 490-492245/1-A Client Sample ID: Method Blank Matrix: Water Prep Type: Total Recoverable Analysis Batch: 492912 Prep Batch: 492245 MS MB Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac Lead <0.0050 0.0050 0.0020 mglL 01/30/1812A6 02/01/1815:37 1 FLab Sample ID: LCS 490-492245/2-A Client Sample ID: Lab Control Sample Matrix: Water Prep Type: Total Recoverable Analysis Batch: 492912 Prep Batch: 492245 Spike LCS LCS %Rec. Analyte Added Result Qualifier Unit D %Rec Limits Lead 0.100 0.102 mg1L 102 85 -115 Method: 1664B - HEM and SGT-HEM Lab Sample ID: MB 490-493630/1-A Client Sample ID: Method Blank Matrix: Water Prep Type: Total/NA Analysis Batch: 493639 Prep Batch: 493630 MB MB Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac HEM <4.0 4.0 1 A mg1L _ 02/06118 1012 02/06/18 10:12 1 Lab Sample ID: LCS 490-493630/2-A Matrix: Water Analysis Batch: 493639 Analyte HEM Client Sample ID: Lab Control Sample Prep Type: Total/NA Prep Batch: 493630 Spike LCS LCS %Rec. Added Result Qualifier Unit D %Rec Limits 41.7 39.48 mgJL 95 78-11a TestAmerica Nashville Page 7 of 15 2/7/2018 QC Sample Results. Client: GaiaTech Inc. TestAmerica Job ID: 490-145301-1 Project/Site: #1142 - LKQ Durham SDG: IMPS Proj# Need/Site# 41478 ; > Method: 9040C _-pH Lab Sample ID: LCS 490492796/1 Client Sample ID: Lab Control Sample ' Matrix: Water Prep Type: e: Total/NA Analysis Batch: 492796 Spike LCS LCS %Rec. Analyte Added Result Qualifier Unit D %Rec Limits�LL,-�� LP 7.00 7.1 SU 101 98-103 Method: SM 2540D - Solids, Total Suspended (TSS) Lab Sample ID: MB 490-49169311 Client Sample ID: Method Blank Matrix: Water Prep Type: TotalINA 1 l Analysis Batch: 491693 o� MB MB Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac Total Suspended Solids <1.0 1.0 0.70 mg/L 01/26/18 22:00 1 r Lab Sample ID: LCS 490-491693/2 Client Sample ID: Lab Control Sample Matrix: Water Prep Type: Total/NA Analysis Batch: 491693 Analyte Total Suspended Solids Spike LCS LCS %Rec. Added Result Qualifier Unit D %Rec Limits 104 100 104 mg1L TestAmerica Nashville Page 8 of 15 21712018 QC Association Summary Client: GaiaTech Inc. TestAmerica Job ID: 490-145301-1 Project/Site: #1142 - LKQ Durham SDG: RPS Proj# Need/Site# 41478 GC VOA -- — -- - -- --- --- Analysis Batch: 491730 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch 490-145301-1 #1142 LKQ Durham TotalINA Water 8015C MB 490-491730/5 Method Blank Total/NA Water 8015C LCS 490-49173016 Lab Control Sample Total/NA Water 8015C Metals Prep Batch: 492245 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch 490-145301-1 #1142 LKQ Durham Total Recoverable Water 200.7 MB 490-492245/1-A Method Blank Total Recoverable Water 200.7 LCS 490-49224512-A Lab Control Sample Total Recoverable Water 200.7 Analysis Batch: 492912 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch 490-145301.1 #1142 LKQ Durham Total Recoverable Water 200.7 Rev 4.4 492245 MB 490-492245/1-A Method Blank Total Recoverable Water 200.7 Rev 4.4 492245 LCS 490-492245/2-A Lab Control Sample Total Recoverable Water 200.7 Rev 4.4 492245 General Chemistry Analysis Batch: 491693 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch 490-145301-1 #1142 LKQ Durham Total/NA Water SM 2640D MB 490-49169311 Method Blank Total/NA Water SM 2540D LCS 490-491693/2 Lab Control Sample Total/NA Water SM 2540❑ Analysis Batch: 492796 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch 490-145301-1 *1142 LKQ Durham Total/NA Water 9040C LCS 490-492796/1 Lab Control Sample Total/NA Water 9040C Prep Batch: 493630 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch 490-145301-1 #1142 LKQ Durham Total/NA Water 1664E MB 490-4936 30/1 -A Method Blank Total/NA Water 16646 LCS 490-493630/2-A Lab Control Sample Total/NA Water 1664B Analysis Batch: 493639 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch 490-145301-1 #1142 LKQ Durham Total/NA Water 1664B 493630 MB 490-493630/1-A Method Blank TotalINA Water 1664E 493630 LCS 490-493630/2-A Lab Control Sample Total/NA Water 1664B 493630 TestAmerica Nashville Page 9 of 15 2/7/2018 Client: GaiaTech Inc. Project/Site: #1142 - LKQ Durham Client Sample ID: #1142 LKQ Durham Date Collected: 01/24/18 11:30 Date Received: -01125118 09:15 Lab Chronicle TestAmerica Job ID: 490-145301-1 SDG: RPS Proj# Need/Site# 41478 Lab Sample ID: 490-145301-1 ; Matrix: Water " I Batch Batch Dil Initial Final Batch Prepared Prep Type Type Method Run Factor Amount Amount Number or Analyzed Analyst Lab Total/NA Analysis 8015C 1 491730 01127/18 16:43 MH TAL NSH , Total Recoverable Prep 200.7 50 mL 50 mL 492245 01130/18 12:46 RDF TAL NSH Total Recoverable Analysis 200.7 Rev 4.4 1 492912 02/01/18 16:34 LCS TAL NSH # r; -; i TotallNA Prep 16646 850 mL 960 mL 493630 02106118 10:12 BAD TAL NSH ! TotallNA Analysis 1664E 1 493639 02/06/18 10:12 BAD TAL NSH TotallNA Analysis 9040C 1 492796 02101/18 12:43 JDG TAL NSH i Total/NA Analysis SM 2540D 1 250 mL 1000 mL 491693 01/26/18 22:00 AEC TAL NSH Laboratory References: , TAL NSH = TestAmerica Nashville, 2960 Foster Creighton Drive, Nashville, TN 37204, TEL (615)726-0177 -- - Page 10 of 15 TestAmerica Nashville 2/7/2018 ;1r i Method_ Summary11 Client: GaiaTech Inc. TestAmerica Job ID: 490-145301-1 Project/Site-, #1142 - LKQ Durham SDG: RIPS Proj# Need/Site# 41478 t1 Method Method Description Protocol Laboratory 8015C Glycols- Direct Injection (GCIFID) SW846 TAL NSH 200.7 Rev 4.4 Metals (ICP) EPA TAL NSH 1664B HEM and SGT-HEM 1664B TAL NSH 9040C pH SW846 TAL NSH SM 2540D Solids, Total Suspended (TSS) SM TAL NSH Protocol References: �i 1664B = 1664B EPA = US Environmental Protection Agency SM = "Standard Methods For The Examination Of Water And Wastewater", LM SW846 = "Test Methods For Evaluating Solid Waste, Physical/Chemical Methods", Third Edition, November 1986 And Its Updates. Laboratory References: TAL NSH = TestAmerica Nashville, 2960 Foster Creighton Drive, Nashville, TN 37204, TEL (615)726-0177 RIA TestAmerica Nashville Page 11 of 15 2/7/2018 Accreditation/Certification Summary 4 Client: GaiaTech Inc. TestAmerica Job ID: 490-145301-1 - Project/Site: #1142 - LKQ Durham SDG: RPS Proj# Need/Site# 41478 Laboratory: TestAmerica Nashville Unless otherwise noted, all analytes for this laboratory were covered under each accreditation/certification below. Authority Program EPA Region Identification Number Expiration Date Arizona State Program 9 AZ0473 05-05-18 The following analytes are included in this report, but accreditation/certification is not offered by the governing authority: Analysis Method Prep Method Matrix Analyte 8015C Water Ethylene glycol Arkansas DEQ State Program 6 88-0737 04-25-18 Florida NELAP 4 E87358 06-30-18 The following analytes are included in this report, but are not accreditedlcertified under this accreditation/certification: Analysis Method Prep Method Matrix Analyte 200.7 Rev 4.4 Louisiana North Carolina (WWISW) South Carolina 200.7 Water Lead NELAP 6 30613 06-30-18 State Program 4 387 12-31-18 State Program 4 84009 (001) 02-28-18 The following analytes are included in this report, but a ccreditationlcertification is not offered by the governing authority: Analysis Method Prep Method Matrix Analyte 8015C Water Ethylene glycol 9040C Water pH Tennessee State Program 4 2008 02-23-20 The following analytes are included in this report, but accreditation/certification is not offered by the governing authority Analysis Method Prep Method Matrix Analyte 1664B 1664B Water HEM 200.7 Rev 4.4 200.7 Water Lead 8015C Water Ethylene glycol 9040C Water pH SM 2540D Water Total Suspended Solids Texas NELAP 6 T104704077 08-31-18 The following analytes are included in this report, but are not accredited/certified under this accreditationicertification: Analysis Method Prep Method Matrix Analyte 200.7 Rev 4.4 200.7 Water Lead Virginia NELAP 3 460152 06-14-18 TestAmerica Nashville Page 12 of 15 2/712018 TestAmedca THE LEADER IN ENVIRONMENTAL TESTING Nashville, TN COOLER RECEIPT FORM 490-145301 Chain of Custody Cooler ReceivedlOpened On 1l2512018 Q 0915_ Time Samples Removed From Cooler Time Samples Placed In Storage (2 Hour Window) 1. Tracking #---��E-(tast 4 digits, FedEx) Courier: FedEx IR Gun ID 31470366 pH Strip Lot Chlorlr! Str! p Lol 2. Temperature of rep. sample or temp blank when opened:ji-�--Degrees Celsius 3. If Item #2 temperature Is 0°C or less, was the representative sample or temp blank frozen? YES � NO..&) 4 Were custody seals on outside of cooler? / YID ' ..N0...NA If yes, how many and where: /�U�2111 1 5, Were the seals intact, signed, and dated correctly? ..NO —NA t�... 6. Were custody papers inside coolar? NO ... NA 1 certify that Ithat I opened the cooler and answered questions 1-6 tlntlagthe cooler and answered questions 1-6 (In/tl�al) 7. Were custody seals on containers: YES DIO } and Intact YES ... NO... Were these signed and dated correctly? (/ // YES...NO-AuCi 8. Packing mall used? Bubt&- a' p PI 1 bag Peanuts Vermiculite Foam Insert Paper Other None 9. Cooling process: Ic Ice -pack Ice (direct contact) Dry ice Other None 10. Did all containers arrive in good condition (unbroken)? 63..NO... NA 11. Were all container labels complete (0, date, signed, pres., etc)? .NO ... NA 12. Did all container labels and tags agree with custody papers? <!!4XNO... NA 13a. Were VOA vials received? ..N0... %6� b, Was there any observable headspace present in any VOA vial? J(EY...NO... NNAA O*0 Larger than this. 14. Was there a Trip Blank in this cooler? YES... .NA If multiple coolers, sequence tk certify that I unloaded the cooler and answered questions 7-14 (intlal) C� 15a. On pres'd bottles, did pH test strips suggest preservation reached the correct pH level? YES ... NO ... NV b. Did the bottle labels Indicate that the correct preservatives were used NO ... NA 16, Was residual chlorine present? YES...NO...i;� I certify that I checked for chlorine and pH as per SOP and answered questions 15-16 Intlal) ` 17, Were custody papers properly filled out (ink, signed, etc)? C�o..NO... NA 18. Did you sign the custody papers in the appropriate place? 6ik'NO... NA 19. Were correct containers used for the analysis requested? zY . ... NO ... NA 20. Was sufficient amount of sample sent in each container? eM92NO... NA I certify that I entered this prolect Into LIMS and answered questions 17-20 intial I certify that I attached a label with the unique LIMS number to each container tintiall C� 21. Were there Non -Conformance issues at Iogln7�...NO Was a NCM generated? Y!0..NO-A R15 a Blaken in shipment Cooler Receipt Form doc LF-1 Revised 8123M End ofform Page 13 of 15 2/712018 ir7--1 TestAmerica Nashville 2966rosterCreighton Drive Chain of Custody Record Nashville, TN 37204 Phone (615) 726-0177 Fax (615) 726-3404 TestAme ica THE LEAVER M FYVIRONKENTAL YEer-.AG SarngEeC Lab PM: Client Information cs� A Knapp, Jim ❑ Carrier Trar3dng No(A): COC No: 490-77836-16518 1 Client Contact Phone: / E-MaH: Seth Ailiff — l jim,knapp@testamericaine.com Page: Page I of I Company: GaiaTech Inc. Analysis Requested Job M Address. PO BOX 12621 pue Date Requested: r. r- a , x n, w `P S u u E 8 a p ? J a m a mo o a c n 4 a $ c i°- Preservation Gales: A-HCL M- Hexane NaOH 8 - NaON -None C - Zn Acetate O - AsNaO2 O - Nix Aad P - Na204S C-NaH504 Q-Na2SO3 F -MBOH R-Na252O3 G-AWhlgr S-H2SO4 H - Asccrb c Add T - TSA Dodecohydrate 1-Ice U- Acetone J -Ul Water V -MCAA K. EOTA W -pH 4-5 L -EnA 2- other (spetity) other: City Knoxville TAT Requested(da s): State, Zp: TNT37912 Phone 404-812-0001(Tel) NEED Email Seth.AililiQrpsgroup.com WO-t: Proj%t Narne: #1142 LKQ Durham project 49008562 site: SSOWX: C- 2 ' a' Sample Identcation Sample as;e sample Time Sample Type (C=comp. G- rah Matrix (w,—,s�wu,,z. o .d.wa er.ty.,gw... Special InstructionslNote: Preservation Gods: X A. N IN 'JD N water i LOG: 490 145301 Possible Hazard Identification = Non -Hazard = Flummablo Skin Irritant Poison 8 Q Unknown E:JRadio)oglcai Sample Disposal (A fee maybe assessed if samples are retained longer than 1 month) Return To Client =Disposal By Lab Archive For Months Deliverable Requested: I, 11, 111, N. Other (specify) Special Instructions/QC Requirements: Empty Kit Relinquished by: Dale: Time: tAe hod of Shipment: Relinquished by. Detemrno: Company I Received by. Dalai fime: Company Relinquished by, Corr:pany Recerveo by Datet7me: Company Relinquished by: Datei lime: Company Remivod by Daremme! ` Co'm--pany --)-A— Custody Seals Intact: Custody Sea! No.: p Yes A No Gooier Temperatures) "C and Other Remarks: co 0 N N r ^i w Bottle. Qrd errlrforinAfbn_' Bottle Order: #1142 LKQ Durham Bot"¢ Order #: 16518 ' Request From Client: 12/31/2017 Data Order Posted: 31912016 7:17:49PM Order Status: Ready To Process Prepared By,- Jim Knapp Deliver By Date: 1/25/2018 11:59:OOPM Lab Project Number: 49008562 JL Order Ciimplgtion-Informatio r Creator: Jim Knapp Filled by: Sent Date: Sent Via: Tracking #: --Sets Bottles/Set — Oty -'Bottle Type Description " Preservative" Method --_Matrix' Sample Type Comments = Lot # 1 2 2 Glass 1 liter Wide- Hydrochloric 1664E - HEM Water Normal ___ _ ro —hydchloric --- __Acid__ 1 3 3 Voa Vial 40mf - unpreserved None 8015C—DAI_GLY - (MOD) Custom Water Normal- - — —2 — — — — — — W — -- — 1 2 Plastic 500ml - unpreserved None 2540D - Total Suspended Solids Water— Normal 1 — 1 — —1 Plastic 250ml - with Nitric Acid Nitric Acid — 200.7 - Lead Water Normal — 1 1 1 Plastic 250m1 - unpreserved Nane 9040C - pN Water Normal — T Notes to1Fleld Staff` 17._ ' Wealth andSafety Not6S:.. r. —Do not rinse out the containers. Preservative Comment --For the 40ml vials with hydrochloric acid for 13TFX testing -- Fill the vial. No headspace or air bubbles should be visible in the filed v'safs. --Ship samples to the tab on the day the samples were taken. Samples can be shipped on Fridays for receipt at the lab on Saturday mornings. --Ship samples, on ice, overnight, to: TestAmerica 2960 Foster Creighton Dr Nashville, TN 37204 --Please complete the pre-printed chain of custody and include with your shipment. Hydrochloric Acid CAUTION! CONTAINS 1:1 HYDROCHLORIC ACID. Avoid skin and eye contact If contact is made, FLUSH WMEDIATFLY with water. Nitric Acid CAUTION! STRONG OXIDIZER! CONTAINS 1:1 NITRIC ACID. Avoid skin and eye contact. If contact is made, FLUSH IMMEDIATELY with water. Loc: 490 145301 Relin shed By Company LrQ Date J/ Time « Received By Company Seal x sit4 Seel #: Seal k Relincr6ished By Company Date Time Received By Company eai k. Please notify us immediately If an error is found in shipment Shipping Order ID: 77836 Page 2 of 2 Printed on 1119/201810:55:13AM N ti N T.. T! W 0) m a CERTIFIED MAID, RETURN RECEIPT REQUESTED Date: Division of Water Quality Attn: Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 RE: LKQ City Auto Salvage Durham, NC Permit # NCG100034 2"d Semi -Annual Stormwater Discharge Outfall Monitoring Report Dear Sir/Madam: RECE.71VED FEB 13 2018 CEN rf7AL FILES DWR SECTION Please find attached the Second Semi -Annual Stormwater Discharge Outfall (SDO) Monitoring Report for the LKQ City Auto Salvage facility located in Durham, North Carolina. This submittal covers the reporting period July 15, to December 315t, 2017. Please call me at 252-474-7819 or Mr. Seth Ailiff of RPS at 404-809-3877 if you have any comments, questions, or concerns about the information presented in this submittal. Sincerely, Bryan Woody Plant Manager Attachment STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT CERTIFICATE OF COVERAGE NO. NCG100034 FACILITY NAME LKQ City Auto Salvage., PERSON COLLECTING SAMPLE(S) Triston Maurice CERTIFIED LABORATORY(S) Test America Lab Nashville Labti490 Part A: Stormwater Benchmarks and Monitoring Results SAMPLES COLLECTED DURING CALENDAR YEAR: 2017 (This monitoring report shall be received by the Division no later than 30 days from the date the facility receives the sampling results from the laboratory.) COUNTY Durham PHONE NO. (252) 474-7819 PLEASE REMEMBER TO SIGN ON THE REVERSE 4 For sampling periods with no discharge, you must submit this discharge monitoring form noting "No Flow" or "No Discharge" within . f 30 days of the end of that period to comply with permit reporting requirements. Outfall No. Date Sample Collected, mo/dd/year Total Rainfall, inches 00400 00530 - - - 77023 01051 78141 pH, Standard Units Total Suspended p Solids (TSS), mg/L Non -polar O&G/TPH (Method 1664 SGT-HEM), mg/L Ethylene Glycol, mg/L Lead, Total Recoverable, mg/L Total Toxic 3 Organics, mg/L Benchmark - - 6.0 — 9.01 100/502 15 8,000 (Tiers 2 and 3) 0.03 1.0 Outfall001 12/28/2017 2.35 7.5 460 <4.3 (Below Recordable Limit) 12 0.048 Exempt Note: If you report a sampled value in excess of the benchmark value, or outside the benchmark range for pH, you must implement Tier 1 or Tier 2 responses in the General Permit. 1See If pH values outside this range are recorded in sampled stormwater discharges, but ambient precipitation pH levels are lower, then the lower threshold of this benchmar' range is the pH of the precipitation (within instrument accuracy) instead of 6 S.U. Readings from an on -site or local rain gauge (or local precipitation data) must be documented to demonstrate background concentrations were below the benchmark pH range of 6-9. 2 See General Permit text to identify whether the more protective benchmark applies for especially sensitive receiving waters. 3 For purposes of this permit the definition of Total Toxic Organics is that list as stated in Appendix D, Table II of Chapter 40 Code of Federal Regulations (CFR) Part 122. Form SWU-251, lastrevised October25, 2012 Page 1 of 2 STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may request that DWQ waive monitoring of total toxic organics. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities allowed such a waiver, the discharger shall sign the following certification statement: Solvent Management Plan Certification Statement "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), certify that to the best of my knowledge and belief, no dumping of.concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing all the provisions of the solvent management plan included in the Stormwater Pollution Prevention �Plan." &.- 40� Name (Pri t name) Title (Pri title) Signature Date Mail Original and one copy to: Division of Water Quality Attn; Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that thereare4gnificant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee or Designee) (Date) Form SWU-251, lost revised October25, 2012 Page 2 of 2 11 CERTIFIED MAIL, RETURN RECEIPT REQUESTED Date: Division of Water Quality Attn: Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 ECFIVE ] RE: LKQ City Auto Salvage 30L 21 2017 Durham, NC GwTF2AL FiLF—S r- Permit # NCGID0034 t,trJ� Sf=,TION 15t Semi -Annual Stormwater Discharge Outfall Monitoring Report Dear Sir/Madam: Please find attached the First Semi -Annual Stormwater Discharge Outfall (SDO) Monitoring Report for the LKQ City Auto Salvage facility located in Durham, North Carolina. This submittal covers the reporting period January 1s1 to June 3011, 2017. Please call me at 252-474-7819 or Mr. Seth Ailiff of RPS GaiaTech at 404-809-3877 if you have any comments, questions, or concerns about the information presented in this submittal. Sincerely, Bryan Woody Plant Manager Attachment STORMWATER DISCHARGE OUTFALL(SDO) MONITORING REPORT CERTIFICATE OF COVERAGE NO. NCG100034 FACILITY NAME LKQ City Auto Salvage PERSON COLLECTING SAMPLE(S) Bryan Woody CERTIFIED LABORATORY(S) Test America Lab Nashville Lab#490 Part A: Stormwater Benchmarks and Monitoring Results SAMPLES COLLECTED DURING CALENDAR YEAR: 2017 (This monitoring report shall be received by the Division no later than 30 days from the date the facility receives the sampling results from the laboratory.) COUNTY Durham PHONE NO. (252) 474-7819 PLEASE REMEMBER TO SIGN ON THE REVERSE 4 For sampling periods with no discharge, you must submit this discharge monitoring form noting "No Flow" or "No Discharge" within 30 days of the end of that period to comply with permit reporting requirements. Outfall No. Date Sample Collected, mo/dd/year Total Rainfall, inches 00400 00530 ---- 77023 01051 78141 pH, Standard Units Total Suspended Solids (TSS), mg/L Non -polar O&G/TPH (Method 1664 SGT-HEM), mg/L Ethylene Glycol, mg/L Lead, Total Recoverable, mg/L Total Toxic 3 Organics, mg/L Benchmark - - 6.0 — 9.0 2 100/50 15 8,000 (Tiers 2 and 3) 0.03 1.0 Outfa11001 6/30/2017 0.12 7.4 21 <4.6 (Below Recordable Limit) <10 (Below Recordable Limit) 0.0020 Exempt Note: If you report a sampled value in excess of the benchmark value, or outside the benchmark range for pH, you must implement Tier 1 or Tier 2 responses in the General Permit. 1See If pH values outside this range are recorded in sampled stormwater discharges, but ambient precipitation pH levels are lower, then the lower threshold of this benchmark range is the pH of the precipitation (within instrument accuracy) instead of 5 S.U. Readings from an on -site or local rain gauge (or local precipitation data) must be documented to demonstrate background concentrations were below the benchmark pH range of 6-9. 2See General Permit text to identify whether the more protective benchmark applies for especially sensitive receiving waters. 3For purposes of this permit the definition of Total Toxic Organics is that list as stated in Appendix D, Table II of Chapter 40 Code of Federal Regulations (CFR) Part 122. Form SWU-251, last revised October25, 2012 Page 1 of 2 STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may request that DWQ waive monitoring of total toxic organics. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities allowed such a waiver, the discharger shall sign the following certification statement: Solvent Management Plan Certification Statement "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." r C1.1 Name (P int name) � K14 '1. � %/j 'ai n a 1 a, - Title (Print ) R � Signature Date Mail Original and one copy to: Division of Water Quality Attn: Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee or Designee) 7/.;? 6,1/ (Date) Form SW U-251, last revised October 25, 2012 Page 2 of 2