Loading...
HomeMy WebLinkAboutNCS000328_EPA Inspection Report_20190603-ISO SZ42, UNITED STATES ENVIRONMENTAL PROTECTION AGENCY a� YZ REGION 4 ATLANTA FEDERAL CENTER oz 61 FORSYTH STREET �lpTq< PRpSEG�\ ATLANTA, GEORGIA 30303-8960 MAY 2 8 9A19 CERTIFIED MAIL 7017 1450 0000 7973 2816 RETURNED RECEIPT REQUESTED Mr. Rick Petrovich R EC F j\1 rD General Manager JUN 03 2019 Bestway South, Inc. 165 Halyburton Road DENR-LAND C UALIV Stony Point, North Carolina 28678 STORMWATER PER[Vih i !NG Re: Compliance Evaluation Inspections Bestway South, Inc., Stony Point, North Carolina NPDES Permit No. NCS000328 . Dear Mr. Hinkle: On March 18, 2019, the U.S. Environmental Protection Agency Region 4 and North Carolina Department of Environmental Quality (NCDEQ) conducted a Compliance Evaluation Inspection (CEI) at the Bestway South, Inc., facility located at 165 Halyburton Road in Stony Point, NC. The purpose of the CEI was to evaluate Bestway South, Inc., facility's compliance with the requirements of Sections 301 and 402(p) of the Clean Water Act (CWA), 33 U.S.C. §§ 1311 and 1342(p); the regulations promulgated thereunder at 40 C.F.R. § 122.26; and, the State of North Carolina's NPDES Stormwater Permit NCS000328. The EPA and NCDEQ appreciate your cooperation in conducting this CEI. Enclosed is the EPA's CEI report, which includes EPA's observations. Please review the report and contact Ms. Lauren Garcia at the NCDEQ office within 14 days of receiving this letter by calling (919) 707-3648 or by sending an email to Lauren. ag rciagncdenr. og_v. There is no need to respond directly to the EPA at this time; however, please note that the EPA will continue to closely coordinate with NCDEQ to ensure compliance at this facility. If you do happen to have questions for the EPA, you can contact Mr. Ahmad Dromgoole at the above address, by email at dromgoole.ahmad@epa.gov, or at (404) 562-9212. Enclosures cc: Ms. Annette Lucas NCDEQ Sincerely, Daniel J. O' L ne, Chief Surface Water and Ground Water Section Water Enforcement Branch Intemet Address (URL) • http://www.epa.gov Recycled/Recyclable • Printed with Vegetable Oil Based Inks on Recycled Paper (Minimum 30 % Postconsumer) 1"'� U.S. Environmental Protection Agency, Region 4 61 Forsyth Street SW, Atlanta, GA 30303 o= Water Compliance Inspection Report FACILITY DATA NPDES ID: NCS000328 Effective Date: 03/01/09 Expiration Date: Administratively Continued Facility Name: Bestway South, Inc SIC Code: 2491 Address: 165 Halyburton Rd, Stony Point, NC 28678 On -Site Representative(s), Title, Phone Number: Responsible Official, Title, Phone Number, Mailing Address: Rick Petrovich Rick Petrovich General Manager General Manager 165 Halyburton Rd 165 Halyburton Rd Stony Point, NC 28678 Stony Point, NC 28678 704-880-7665 704-880-7665 INSPECTION 1- Entry Date/Time: 03/18/19, 2:50 pm Exit Date/Time: 03/18/19, 6:45 pm NAMES OF EPA AND STATE INSPECTORS EPA Inspectors: Ahmad Dromgoole, Kenneth Kwan NCDENR Inspectors: Zahid Khan, Isaiah Reed, Stan Aiken AREAS1 DURING INSPECTIONareas X Permit Self -Compliance Program Pretreatment X Records Compliance Schedule Pollution Prevention X Facility Site Review Laboratory X Storm Water X Effluent / Receiving Waters X Operations & Maintenance Combined Sewer Overflow Flow Measurement Sludge Handling/ Disposal Sanitary Sewer Overflow INSPECTION NOTES The inspection team, consisting of EPA inspectors and state inspectors from various regional offices, arrived at the facility on March 18, 2019 to perform an unannounced Compliance Evaluation Inspection (CEI). This CEI was performed as both a joint inspection with the state and a training opportunity for state inspectors. Upon arrival at the facility, EPA inspectors presented credentials and facilitated an opening conference. The CEI included both a records review portion and a facility walk through. Upon completion, an exit conference was held with facility personnel in which they were informed of EPA's preliminary findings and told that an actual inspection report will be sent to the facility by EPA. ., REPRESENTATIVES Inspector Signature/Name Office/Phone Number Date USEPA Region 4/WPD-CWEB-SRES 404-562-9212 Ahmad Dromgoole, Environmental Engineer USEPA Region 4/WPD-CWEB-SRES 404-562-9752 Kenneth Kwan, Environmental Engineer Management Signature/Name Office/Phone Number Date USEPA Region 4/WPD-CWEB-SRES 404-562-9434 Daniel J. O'Lone, Chief Stormwater and Residuals Enforcement Section Page 1 of 6 GPS Coordinates Coordinates 1. FACILITY LOCATION I' 1 Latitude 35051'24.11"N Longitude 8101'58.75"W Receiving Water(s) or Unnamed Tributary to Site 23 total acres Weather Partially Cloudy MS4 Third Creek Acreage Condition N/A, permit No, Class Does the site continue renew Discharge to 303(d) C stream in discharge pollutants Permit under NPDES SIC 2491 listed or TMDL the Yadkin contributing to the No Application permit Code(s) waters Pee -Dee receiving stream L_ NCS000328 River Basin impairment. 2. BASIC 1 SPPP TOPICS (Part H) YES NO N/E SPPP on -site (dated, signed, and annual review) Section A X The SPPP was not dated, signed and annually updated. Site Description Section A(1)(b) X (storage practices, loading/unloading activities, outdoor processes, dust generating processes, and waste processes) Identify potential Pollutant Sources and Particular Pollutants Section A(1)(b) X (include inventory of materials handled at the site, information pertaining to any pollutant sources, information pertaining to the storage and application of pest control chemicals) Site Maps (general location map and site specific map) Sections A(1)(a & c) X (include identification of receiving waters and/or MS4s, identification of impaired waters, lat/long of discharge points, drainage areas to each discharge point, site boundaries, site topography, drainage features and flow directions, impervious areas, industrial activities, and site best management practices (BMPs) The site map did not outline the site property boundary, the stormwater outfall location, name of receiving water, and storm drains. Spill History (3 year history or spills and corrective actions) Section A(1)(d) X Significant leaks and spills in the 3 previous years was reported as "none" in the SPPP. However, it is uncleared as to the timeframe since the SPPP was not dated and has not been updated recently. SPPP Certification Section A(1)(e) X (Annual recertification of no evidence of non-stormwater discharging) The non-stormwater discharge certification in Section 4.17 of the SPPP was not filled out. The form also needed to have a certification statement in accordance with Part III, Section B. Paragraph 3.c. of the permit. Stormwater Management Strategy (Feasibility Study) Section A(2)(a) X (Analysis of control options like eliminating exposure or controlling runoff) The SPPP did not contain a feasibility study on material management practices. Stormwater Management Strategy (Secondary Containment) Section A(2)(b) X The SPPP did not have a table or summary of all process chemical tanks, list of storage materials, and their associated secondary containment capacity. Also, the SPPP did not address the procedure for how to release the accumulated stormwater within the containment area. Stormwater BMP Summary Section A(2)(c) X The SPPP listed BMPs such as silt fence and rip rap check dams in drainage ways for the lumber and residue 11 storage areas. These BMPs were not observed on -site. The SPPP has no written record of the specific rational Page 2 of 6 2. BASIC STORMWATER POLLUTION PREVENT INFORMATION SPPP TOPICS (Part II) YES NO N/E for not installing these two selected BMPs Spill Prevention & Response Procedures (SPRP) Section A(3) X (Stormwater specific plan identifying the various responsible officials and their signatures) Preventative Maintenance and Good Housekeeping Program Section A(4) X (address maintenance and cleaning schedules of control systems, outfalls, adjacent waters, handling of industrial activities, drainage structures, and BMPs) Employee Training Section A(5) X (minimal annual training of spill response and cleanup/prevention and potential areas of industrial stormwater) No records regarding annual employee training were made available to EPA during the inspection. Also, the facility personnel responsible for implementing the training was not identified in the SPPP, and their trainings were not documented by the signature of each employee trained. Identify the Responsible Party Section (A)(6) X SPPP Modified or Update to Current Conditions Section (A)(7) X (review and update at least annually, recertify, and include the review of most recent benchmarks samples) No record of annual review or amendments to the SPPP were made available to EPA for review. Schedule and Procedures for Routine Inspections (minimum of semiannually) Section A(8) X Bestway South operates a lumber treating and dry kiln facility in Stony Point, NC. The facility operates as a treating service only since it does not own any lumber products. At this facility, raw lumber is received in various dimensions, treated, dried, and packaged for shipping. The primary raw materials at the since include untreated lumber and treatment chemicals. The facility uses two primary treating chemicals (copper/chromium/arsenate and copper azole). These lumber treatment chemicals are received by tanker truck in small quantities such as totes and barrels and are housed inside. The facility operates one batch treatment process unit. Raw lumber is loaded into the pressure vessel were once sealed, treatment chemicals are introduced, and the vessel is placed under various pressures. Once treated, the lumber is allowed to drip dry in a bermed area which drains back to a catchment directed back to the process. The treated lumber is stored outside in uncovered piles throughout the site prior to shipping. Stormwater is collected via storm drains and routed to a detention pond before discharge to receiving water. 4. RECORD REVIEW Record Review YES NO N/E Representative on -site X Records of the Implementation of the SPPP Part II Section A(9), Part III Section D(6) X Although some of the records pertaining to the implementation of the SPPP were available, a number of records were not maintained including some of the training and housekeeping records. Records of Maintenance and Housekeeping Programs Part II, Section A(9) X Records pertaining to housekeeping measures including sweeping, visual inspection of tanks, and equipment were not made available during the inspection. Records of Routine Inspections Part II, Section A(9) X Weekly inspection records of the facility back to 2017 were available and reviewed during the inspection. However, these inspections focus only on the loading/unloading areas. The BMP controls and seven industrial Page 3 of 6 4. RECORD Record Review YES NO N/E activities identified in Section 4.a. of the SPPP were not evaluated as part of the routine inspections of all industrial material and activities that are exposed to stormwater. Records of Employee Training Part II, Section A(9) X Records of employee training were requested for review during the inspection. According to facility personnel, employees receive initial training but did not receive annual refresher training. Records for the Approval of Representative Outfalls Part III Section D(5) The facility did not seek approval of a representative outfall. X Records of Benchmark Monitoring Part II, Section B & D, Part III Sections D, & E(1) X Benchmark monitoring records were reviewed back through 2016. According to the monitoring records, all of the sample analysis was performed at the contracted lab. This included pH which according to the test method requires analysis within 15 minutes of pulling the sample. The 15 minute holding time was being exceeded by having the lab run this analysis off -site. Records of Qualitative Monitoring Part II Section C, Part III Section D X Qualitative monitoring records were reviewed back through 2016. From the records review, qualitative monitoring records of stormwater discharge at the outfall were not available after 2016. Records of Tiered Approach to Benchmark Exceedances Part III Sections B X Due to exceedances of the copper benchmark, the facility has been considered Tier II since 2009. A requirement of Tier II is that monthly monitoring begin for all parameters at the exceeding outfall(s) and that records be maintained of the tiered response in the plan. A review of the plan did not show additional measures being put in place nor did the facility begin monthly monitoring for all parameters. Records of Bypasses Part III Sections E(7) X Although the SPPP had a page to summarize bypasses, no updates or information was provided on the form. The permit required a listed of significant spills or leaks during the previous three years. A date with specific year entry should have been included on the form certifying that in the past three years there were no bypasses to report. Records of 24 hr Reporting Part III Sections E(8 &9) X EVALUATION5. SITE 1 Pollutant Sources Note location, quantitative description, design issue, O&M deficiencies (including the nature and extent), and pollutants off -site Loading/Unloading Raw materials and products from the site are transferred to and from the site by truck (as seen in photo Area DSCN1818). These trucks access the site through the entrances on the north side. Untreated and treated lumber at the site is stored outdoors in piles around the site. The lumber piles were Outdoor Storage observed as being off the ground on wooden spacers (to allow for forklift access and eliminated the exposure Facilities (log and to stormwater runoff along the ground). These piles were observed as not being under any cover to minimize milled material) contact with stormwater as seen in photographs DSCN1817-DSCN1819, DSCN1822-DSCN1823, and DSCN1829. The facility operates one pressure treating vessel located near the center of the facility. Lumber is loaded and unloaded from the vessel by the rail system seen in photos DSCNI820 and DSCN1827. The facility also operates a wood drying kiln near the northwest corner of the site. At the treatment unit, a concrete berm was Treating, Preserving, in place around the treatment area used to contain drips and spills from the process (see photos DSCN1820- and Assembly DSCN1821). The area within the contained area drains to a catchment which is directed back to the day tank. Processes A boiler house was located near the southwest cover of the site. The boiler and associated equipment were all staged inside of the building. In addition to the operation of the boiler, the facility also performs cleaning and blowdown operations in the building. A discharge pipe, seen in photos DSCN1830-DSCNI831, was observed Page 4 of 6 5. SITE EVALUATION & SWP3 IMPLEMENTATION Pollutant Sources Note location, quantitative description, design issue, O&M deficiencies (including the nature and extent), and pollutants off -site on the south side of the boiler house. According to facility personnel, this pipe drains water from the boiler house from things like boiler blowdowns and washouts. Photograph DSCNI831 shows evidence of rust/iron accumulation around the outlet. This water, which would likely continue south to the ditch leading to the stormwater pond, would be a non-stormwater discharge. Bestway institutes a number of the housekeeping measures to manage its stormwater runoff in addition to its retention pond. These housekeeping measures include, but are not limited to, the staging of the treatment process inside of the bermed area and the staging of treated wood inside of the containment area for a minimum amount of time to allow for residual chemicals to be captured and recycled (see photo DSCN1827). Housekeeping During the walk through of the facility, some areas of the site were observed lacking good housekeeping practices. This included the drainage structures which were observed with sand/sediment accumulation (see photos DSCNI819 and DSCN1923). Additionally, the facility has consistently been exceeding its copper benchmark which is tied to one of its treatment chemicals. During the inspection, the facility was observed to have treated lumber in close vicinity of storm drain inlets (see photo DSCN1819). Liquid Storage The treatment chemicals used at the facility are typically housed inside of the bermed treatment area. The Tanks primary treatment chemicals are maintained in above ground tanks. These tanks have loading spigots accessible from the outside of the building but still inside of the bermed processing area (see photo DSCN1828). BMPs such as silt fence and rip rap check dams as specified in the SPPP for the lumber storage areas and residue storage areas were not observed on -site. The area around the facility is a combination of pervious and impervious surfaces. Along the south side of the site, a series of storm drain inlets were observed and can be Stormwater and seen in photos (DSCN1819 and DSCN1829). These storm drains discharged to the drainage ditch on the south Sediment & Erosion side of the site leading to the detention pond (seen in photo DSCN1832). At the southeast corner of the site, Controls (BMPs) the facility maintains a detention pond (seen photos DSCN1833-DSCN1834) which discharges to its one monitored outfall. In addition to the discharge structure on the south side of the site, a drainage ditch not identified in the SPPP as an authorized outfall was observed running north/south through the middle of the site near the treatment process (see photos DSCN1823-DSCN1824). Disposal/Waste Waste material at the site is primarily disposed of in outdoor dumpsters. One of these dumpsters, seen in photo Handling Areas DSCN1826, was observed on the north side of the site and was uncovered. Waste chemicals from the process can be discarded to drums or tote for disposal. Vehicle Maintenance Areas No outdoor maintenance activities were observed. STORMWATER Outfall, Stormwater Discharge & YES NO Receiving Water DISCHARGE & RECEIVING WATER OBSERVATIONS Describe: According to the facility's current SPPP, the one outfall identified was the outfall Number & location from the detention pond near the southeast corner of the property. This is the outfall, seen in of stormwater photograph DSCN1835. It is sampled by facility personnel and monitored for benchmarks. A discharge(s)/outfall(s) X second outfall was identified during the inspection discharging from the ditch running through consistent with the the center of the property (seen in photo DSCN1823) and discharging on the north side of the SPPP property (seen in photos DSCN1824-1825). This second outfall was not identified in the SPPP as an authorized stormwater outfall. Evidence of off -site accumulation of Describe: Although some sediment accumulation was observed in the drainage features and pollutants observed X around storm drain inlets around the site, offsite sediment accumulation was not observed during in receiving water the inspection. Page 5 of 6 6. OUTFALL, STORMWATEROBSERVATIONS Outfall, Stormwater Discharge & YES NO Receiving Water Non-stormwater Describe: The boiler room on the south side of the property was observed as having a drainage discharge observed X valve used to purge accumulated water from washouts and blowdowns. These discharges would be considered non-stormwater discharges. Additional inspection summary, narrative, findings, comments, photos, and schematic diagram of the facility area as necessary: An exit conference was held with Rick Petrovich where the following observations were relayed: • SPPP Observations o There were no signature updates of the SPPP o The spill records in the plan were not annually updated o The non-stormwater discharge certification in Section 4.f of the SPPP was not filled out o The site plan did not account for or identify stormwater drains o The site plan did not include the necessary feasibility study o The SPPP did not include or document the increased measures implemented by the site in response to the benchmark exceedances. • Records Observations o No annual employee training records on stormwater pollution prevention o Sampling for pH was not performed in the field and therefore not being analyzed within the alloted 15 minutes in the test method o The facility has been operating at the Tier II level for several years due to benchmark exceedances for copper. Although copper monitoring was performed at the increased monitoring frequency, the remaining parameters were not being monitored at the increased frequency o No qualitative visual monitoring of stormwater discharge at outfall has been performed at the site since 2016 • Site Observations o An additional outfall was identified on the north side of the site that was not in the SPPP o Some sediment accumulation was observed near storm drain inlets throughout the site o Some storage of treated lumber was observed within feet of storm drain inlets o The BMPs identified in the plan such as silt fence and rip rap check dams were not observed at the site o Process water from the boiler room was observed being directed to the stormwater drains Page 6 of 6 SW-NCSO00328-031819 Photolog Bestway South, Inc 165 Halyburton Rd Stony Point, NC 28678 Overview Map SW-NCS000328-031819 Photolog Page 1 of 20 DSCN1817.JPG NIG w 0&x 1 Attributes File Name DSCN1817.JPG Description Photograph of outdoor storage piles. Piles of both untreated lumber and treated wood products were located throughout the facility. Wood piles were slightly off the ground (to allow for forklift access) in uncovered areas. Latitude N 35° 51' 23.50" Longitude W 81' 01' 57.03" SW-NCS000328-031819 Photolog Page 2 of 20 DSCN1818.JPG ,r a Attributes File Name DSCN1818.JPG Description Photograph of outdoor storage piles. Piles of both untreated lumber and treated wood products were located throughout the facility. Wood piles were slightly off the ground (to allow for forklift access) in uncovered areas. Latitude N 35° 51' 23.44" Longitude W 81' 01' 57.08" SW-NCS000328-031819 Photolog Page 3 of 20 DSCN1819.JPG Attributes File Name DSCN1819.JPG Description Photograph of one of the storm drain inlets along the south end of the site. These storm drains discharge to the diversion ditch leading to the retention pond. Some sediment accumulation was observed around the inlets. No control measures were observed during the inspection for the prevention of sediment discharge to the storm drain. Latitude N 35' 51' 22.55" Longitude W 81' 01' 57.34" SW-NCS000328-031819 Photolog Page 4 of 20 DSCN 1820.J PG r 1 —NC-N 5 e a t ■ • • s t'� f' • • i *i •f l Attributes File Name DSCN1820.JPG Description Photograph of the treatment area in the middle of the site. The treatment unit and chemical storage tanks were all located inside of the building. The loading and unloading sides of the process were observed on the north and south sides of the building. The area around the treatment building was covered and had a berm structure used for the containing of process water and chemicals so that they can be recycled to the process. The area inside of the berm is used for the drying of material immediately after treatment. Latitude N 35' 51' 22.96" Longitude W 81' 01' 58.66" SW-NCS000328-031819 Photolog Page 5 of 20 DSCN1821.JPG • i r '- a fT — �• d Attributes File Name DSCN1821.JPG Description Photograph of the bermed area around the treatment area. Inside of this area, staining was observed from excess treatment chemicals accumulated from the products. This excess material was collected in the bermed area and directed to the ditch around the perimeter which leads to the catchment inside of the building. Material from this catchment is recycled to the process. Latitude N 35' 51' 22.78" Longitude W 81' 01' 58.24" SW-NCS000328-031819 Photolog Page 6 of 20 DSCN 1822.J PG � V t .0 � may+ ° Attributes File Name DSCN1822.JPG Description Photograph of outdoor storage piles. Piles of both untreated lumber and treated wood products were located throughout the facility. Wood piles were slightly off the ground (to allow for forklift access) in uncovered areas. Latitude N 35° 51' 23.08" Longitude W 81' 01' 58.58" SW-NCS000328-031819 Photolog Page 7 of 20 DSCN 1823.J PG ■ R T ! V + ! 2 y # i • J Attributes File Name DSCN1823.JPG Description Drainage feature, running south to north, through the middle of the site. This drainage feature appeared to discharge to the northern property boarder and had sediment accumulation which appeared to discharge off site. This discharge point was not identified in facility's SPPP as an authorized outfall. Latitude N 35' 51' 25.76" Longitude W 81' 01' 59.06" SW-NCS000328-031819 Photolog Page 8 of 20 DSCN 1824.J PG F rt r Attributes File Name DSCN1824.JPG Description Drainage feature, running south to north, through the middle of the site. This drainage feature appeared to discharge to the northern property boarder and had sediment accumulation which appeared to discharge off site. This discharge point was not identified in facility's SPPP as an authorized outfall. Latitude N 35' 51' 25.57" Longitude W 81' 01' 59.17" SW-NCS000328-031819 Photolog Page 9 of 20 a PO-9k,.ta!'G!rbe. USDA Farm Service Agency DSCN 1826.J PG ti J Vrt "Mir. It ■ # *RENEW r i • • SIR I� o 11 ' Attributes File Name DSCN1826.JPG Description Photograph of an uncovered waste dumpster at the site. Latitude N 35° 51' 25.21" Longitude W 81' 01' 59.21" SW-NCS000328-031819 Photolog Page 11 of 20 DSCN1827.JPG .F rI * r • ; * i Attributes File Name DSCN1827.JPG Description Photograph of the treatment area in the middle of the site. The treatment unit and chemical storage tanks were all located inside of the building. The loading and unloading sides of the process were observed on the north and south sides of the building. The area around the treatment building was covered and had a berm structure used for the containing of process water and chemicals so that they can be recycled to the process. The area inside of the berm is used for the drying of material immediately after treatment. Latitude N 35' 51' 25.00" Longitude W 81' 01' 58.38" SW-NCS000328-031819 Photolog Page 12 of 20 DSCN 1828.J PG Attributes File Name DSCN1828.JPG Description Photograph of the area along the outside of the treatment building were treatment chemicals are pumped to the holding tanks. The loading points for the tanks were behind the doors along the side of the building and located within the bermed area leading to the catchment system. Latitude N 35' 51' 23.89" Longitude W 81' 01' 57.29" SW-NCS000328-031819 Photolog Page 13 of 20 DSCN 1829.J PG Cem Attributes File Name DSCN1829.JPG Description Photograph of another storm drain inlet along the south side of the site. This inlet was observed in close proximity of outdoor storage of treated lumber. This storm drain connects to the drainage ditch leading to the detention pond. Latitude N 35° 51' 22.48" Longitude W 81' 01' 54.71" SW-NCS000328-031819 Photolog Page 14 of 20 DSCN 1830.J PG Attributes File Name DSCN1830.JPG Description Photograph of the outlet pipe from the boiler house. The boiler house has a catchment which discharges to this pipe. Periodically, the company performs blow downs and washouts of the boilers. This water is accumulated in the catchment and directed to this outlet. Some evidence of rust was observed around the outlet of the pipe. Latitude N 35' 51' 22.66" Longitude W 81' 01' 53.69" SW-NCS000328-031819 Photolog Page 15 of 20 DSCN1831.JPG Attributes File Name DSCN1831.JPG Description Photograph of the outlet pipe from the boiler house. The boiler house has a catchment which discharges to this pipe. Periodically, the company performs blow downs and washouts of the boilers. This water is accumulated in the catchment and directed to this outlet. Some evidence of rust was observed around the outlet of the pipe. Latitude N 35' 51' 22.75" Longitude W 81' 01' 53.89" SW-NCS000328-031819 Photolog Page 16 of 20 DSCN 1832.J PG Attributes File Name DSCN1832.JPG Description Photograph of the drainage ditch in which the storm drains along the south end of the site discharge. This ditch directs the stormwater runoff to the detention pond. Latitude N 35° 51' 22.49" Longitude W 81' 01' 51.19" SW-NCS000328-031819 Photolog Page 17 of 20 Y! Y' 1 ..a .; i.'- L t �• LIB ... i f ._ � � •'-•• .aTY_���-'y^ _ `.�. �ti �L�Y•� 1 -� •-may, .- -\--�� '�I•��� . liz, �, .•� - �: iL' ���� �'-i � ])ii{{{•��--may, - -:��_ _���- . , •� 'eta i ..� �• .�, i �. i � tF � '. 'low 1 aC ,r �� ��Y �'SEY� f e�_ ►►►111 ��-�. �•' t 1 -fj r � �. � .. "{� ��. 1• y # � *a * a t CCC A 1. km -. •�„' r��� "+��'s °�•_ ,+�i� :'_c'1 - y °ram �' ��:� ■ .c� _ � .. - � 1 .r . AAuto Repair ti LocIS-'.La rtie — O nstructio n PLO, i�,t IGbbe, USE! A- Farm Service Agency i • \ L PIPs Auto Repalf Lane Construction . . }Gknbe, USDA Farm SerwweAgsrGy DSCN1835.JPG l y+ �.v t� f 03 18 0 0 `2AvF-a: Attributes File Name DSCN1835.JPG Description Photograph of the stormwater outfall from the site. Latitude N 35' 51' 22.03" Longitude W 81' 01' 45.49" SW-NCS000328-031819 Photolog Page 20 of 20