Loading...
HomeMy WebLinkAboutSW5190401_BMP Supplement Form Resubmittal_6/13/2019SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 1 Project Name NCCU Student Center 2 Project Area ac 4.55 3 Coastal Wetland Area ac 4 Surface Water Area ac 5 Is this project High or Low Densi • High 6 Does this project use an off -site SCM? No COMPLIANCE WITH 02H .1003(4) 7 Width of vegetated setbacks provided feet NIA 8 Will the vegetated setback remain vegetated? 9 Is BUA other that as listed in .1 0034 c-d out of the setback? 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 Infiltration System 0 12 Bioretention Cell 0 13 Wet Pond 0 14 Stormwater Wetland 0 15 Permeable Pavement 0 16 Sand Filter 1 17 Rainwater Harvesting RWH 0 18 Green Roof 0 19 Level Spreader -Filter Strip LS-FS 0 20 Disconnected Impervious Surface (DIS) 0 21 Treatment Swale 0 22 DryPond 0 23 StormFilter 0 24 Silva Cell 0 25 Bayfilter Filterra 0 26 0 FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: Jonathan Allen 28 Or anization: CALYX Engineers 29 Street address: yon Road 6750 Tr 30 City, State, Zip: _ Cary, NC, 27518 31 Phone numbe s _: 919-858-1831 32 Email: jallen@calyxengineers.com Certification Statement: I certify, under penalty of law that this Supplement-E:Z form and all supporting information were prepared under my direction or supervision; that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent Lwith the information provided here_ Oesi ner 2)49,7 ............ C2*tztff' Sign of Designer Date 3 SAND FILTER 1 Drainage area number Design volume of SCM (cu ft) 2 2 s E 3 4 Is the SCM sized to treat the SW from all surfaces at build -out? Is the SCM located away from contaminated soils? What are the side slopes of the SCM (H:V)? gees Yes 5 6 7 Does the SCM have retaining walls, gabion walls or other engineered side slopes? Are the inlets, outlets, and receiving stream protected from erosion (10- year storm)? No Yes 8 Is there an overflow or bypass for inflow volume in excess of the design volume? Yes 9 What is the method for dewatering the SCM for maintenance? Drawdown Orifice 10 If applicable, will the SCM be cleaned out after construction? No Yes 11 Does the maintenance access comply with General MDC (8)? 12 Does the drainage easement comply with General MDC (9)? 13 If the SCM is on a single family lot, does (will?) the plat comply with General MDC (10)? Is there an O&M Agreement that complies with General MDC (11)? 14 Yes Yes Yes es 15 Is there an O&M Plan that complies with General MDC (12)? 16 Does the SCM follow the device specific MDC? 17 as t e designedy an licensedpro essional? SAN13 FILTER MDC FROM 02H 1056 18 19 SHWT elevation (fmsl) _ Type of sand filter (open or closed) 340 Closed Pre Cast 20 If closed, will the filter will be pre -cast or pour -in -place? 21 If closed, top of grate elevation (fmsl) 352.5 22 Is this sand filter designed to attenuate peak flows? No Sediment Chamber 23 Volume that can be retained in the sediment chamber (cubic feet) Will there be a permanent pool in the sediment chamber? 420 of 24 Yes 344.00 105 st 25 Bottom of the sediment chamber (fmsl) 26 Area of the sediment chamber (square feet) 27 28 Physical depth of the sediment chamber (inches) Ponding depth in the sediment chamber, above any permanent pool (inches) 8 in 48 in 346.75 29 Elevation of top of weir between chambers (fmsl) Sand Chamber 30 Volume that can be retained in the sand chamber (cubic feet) 420 of 31 Bottom of the sand chamber (fmsl) 344.00 105 sf 32 Area of the sand chamber (square feet) 33 Physical depth of the sand chamber (inches) 18 in 34 Ponding depth in the sand chamber, above any permanent pool (inches) 48 in 350.75 35 Elevation of the bypass device (fmsl) 36 Type of bypass device Weir 37 Mechanism for distributing flow over the sand surface Rip rap 38 Sand specification for sand chamber ASTM C33 39 Depth above underdrain pipe (inches) 25 in 40 Will the media be maintained to drain at least two inches per hour at the sand surface? Yes 41 Is at least one clean -out pipe provided at the low point of each underdrain line? c can -out pipes be cappe�0 Yes 42 Yos ADDITIONAL INFORMATION 43 Please use this space to provide any additional information about the Sand Filter(s): Sand Filter 1 3:04 PM 6/13/2019 DRAINAGE AREAS 1 Is this a hi h density project? Yes 2 Drainage Areas, 2 If so, number of drainage areas/SCMs 1 SCM Is all/part of this project subject to previous rule 3 versions? No CLICK TO LOAD FORM DRAINAGE AREA INFORMATION Entire Site 4 Type of SCM Sand Filter 5 Total BUA in project (sq ft 125449 sf 14052 sf 6 New BUA on subdivided lots (subject to rmittin s ft 7permitting) New BUA outside of subdivided lots (subject to sf 125449 sf 14052 sf 8 Offsite - total areas ft 9 Offsite BUA (sq f Breakdown of new BUA outside subdivided lots: Parkin s(sq ft] Sidewalk (sq ft) Roof (sq ft) Roadw2y is fti Future (s3 ft) Other, please specify in the comment box below (sq ft) New infiltrating permeable pavement on subdivided lots (sq ft 10 46403 sf 13903 sf 11 27362 sf 149 sf 51684 sf 12 New infiltrating permeable pavement outside of subdivided lots (sq ft 13permitting) Exisitng BUA that will remain (not subject to (sq ft) 14 Existing 8UA that is already permitted (sq ft) 15 Existing BUA that will be removed {sg 122054 sf 7788 sf 16 -17 Percent BUA D_esign storm (inches) Des gn volume of SCM (cu ft) Calculation method for design volume 63% 89% 18 1 in 833 cf 1 in 833 cf 19 Simple Sim le ADDITIONAL INFORMATION Please use this space to provide any additional information about the 20 drainage area(s): The site is divided into 2 drainage areas. Only 1 SCM is proposed. The sand filter is located in Drainage Area #2. DRAINAGE AREA INFORMATION Entire Site t 4 T e of SCM WA 5 6 Total BUA from project (sq ft) 1995 rules SL 2006-246 2008 rules 2017 rules 7 New BUA on subdivided lots (subject to permitting) (sq ft) 1995 rules _ SL 2006-246 _ 2008 rules 2017 rules New BUA outside of subdivided lots (subject to permitting) (sf) 1995 rules SL 2006-246 2008 rules 2017 rules Offsite - total area (sq tt) 8 9 1995 rules SL 2006-246 2008 rules 2017 rules 10 Offsite BUA (sq ft) 1995 rules SL 2006-246 2008 rules 2017 rules