Loading...
HomeMy WebLinkAboutSnow Creek Wetland Mitigation Site, Final Design (Sheets G-001 – G-603)© 2025 Microsoft Corporation © 2025 TomTom ckdbyno.date description PN 186472 FINAL DESIGN SNOW CREEK WETLAND SNOW CREEK, VA FEBRUARY 27, 2026 VICINITY MAP: SCALE 1:20,000 APPROX. PROJECT LOCATION MITIGATION SITE FRANKLIN COUNTY N CHRIS YOW CIVIL ENGINEER License No. 0402052534 Burns & McDonnell Engineering Co, Inc. 110 FRANKLIN RD SE SUITE 700 ROANOKE, VA 24011 816-333-9400 LICENSEE NO. 0411001221 Sheet List Table Sheet Number Sheet Title G-001 COVER G-002 GENERAL NOTES C-001 EXISTING CONDITIONS C-002 WATER BUDGET C-101 GRADING PLAN C-102 WETLAND PROFILES C-301 PLANTING PLAN C-302 PLANTING SCHEDULE C-401 SITE ACCESS AND ESC PLAN C-402 ESC DETAILS C-403 ESC DETAILS 2 C-501 DETAILS C-601 CREDIT ANALYSIS SUMMARY C-602 WETLAND VALUE AND FUNCTION SCORE SHEETS C-603 MONITORING WELL AND PHOTO MONITORING LOCATIONS CLYJCSA08/11/25 VADEQ SUBMITTAL CLYJCSB09/18/25 VADEQ SUBMITTAL (REVISED) CLYJCSC02/05/26 VADEQ SUBMITTAL (REVISED) CLYJCSD02/17/26 USACE SUBMITTAL (REVISED) ckdbyno.date description CLYJCSE02/27/26 USACE SUBMITTAL (REVISED) Sc a l e F o r M i c r o f i l m i n g In c h e s Mi l l i m e t e r s no.date descriptionby 1 1312111098765432 I H G F E D C B A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file ckd J. STOUT C. YOW FEBRUARY 2026 J. STOUT 15 SNOW CREEK WETLAND MITIGATION SITE Burns & McDonnell Engineering Co, Inc. 110 FRANKLIN RD SE SUITE 700 ROANOKE, VA 24011 816-333-9400 LICENSEE NO. 0411001221 CHRIS YOW CIVIL ENGINEER License No. 0402052534 186472 G-002 GENERAL NOTES CONSTRUCTION SEQUENCE AND SPECIFICATIONS 1.Contractor to Comply with the Site-Specific Health and Safety Plan including all premobilization forms, AHAs and PTAs. 2.Install construction entrance, staging areas, haul roads, erosion and sediment control measures. 3.Soil preparation and amendment plan - In general, existing vegetation is sprayed with herbicide, dead vegetation removed, topsoil stripped, sub-grade removed to desired elevation, salvaged topsoil re-spread, and soil amendment to topsoil added if necessary. See steps 4 and 5 for specific plan based on creation or enhancement areas. 4.Spray proposed wetland creation areas with herbicide to kill non-native grasses and vegetation that will be invasive to the native wetland vegetation that will be planted. 5.Wetland Creation Areas a.Cut and rake 7 days after herbicide application. Remove dead vegetation, place in the soil disposal area. b.Strip (top 4”) and stockpile topsoil in the soil disposal area. c.Grade sub-grade to depth according to grading plan, transport excess soil to soil disposal area. d.Grades to be checked by Contractor and validated by the Engineer before moving to the next step. e.Recover areas with stockpiled topsoil, 4-inch depth. f.Disk to depth of 6-8 inches in a crisscross pattern. g.Seed and plant per Planting Plan. 6.Wetland Enhancement Areas a.Remove and dispose of drain tiles 2 drains approximately 200 LF each. b.Conduct minor grading for connection to wetland creation areas. c.Grades to be checked by Contractor and validated by the Engineer before moving to the next step. d.Disk to depth of 6-8 inches in a crisscross pattern. e.Seed and plant per Planting Plan. 7.Install water control structures to plug existing ditch. Each structure will consist of a gravel base filter, 12 inch thick, 4'x12' in area, approximate 12 boulders 2'x3'x4' backed by non-woven filter fabric. 8.Finish grading soil disposal area, seed and straw mulch. 9.Install fence and gates. Fence shall be composed of 4 strand barb wire, metal posts. Typical 10' agriculture style gates, 3 total. 10.Restore haul roads (rip/disc, seed and straw mulch.). 11.Remove debris from site. Construction debris, woody debris is not allowed to be disposed of on site. 12.Submit As-Built Drawings to the Engineer. Contractor may not move to next step until As-Built Drawings have been submitted and approved. 13.Once temporary ESC vegetation is stable remove erosion and sediment control measures, restore temporary impacts, and demobilize. 2 Z:\CLIENTS\ENS\MTNVALLEYPIP\186472_MITIGATIONBANK\DESIGN\CADD\DWGS\PROD DWGS\GENERAL NOTES.DWG SAVED BY:JCSTOUT © 2025 Microsoft Corporation © 2025 Maxar ©CNES (2025) Distribution Airbus DS CH A R L E S D A V I D M I T C H E L L LY N O R A G . M I T C H E L L CH A R L E S D A V I D M I T C H E L L LY N O R A G . M I T C H E L L JUDY W. GARDNER ESTATE JEFFERY W. TURNER JESSICA C. MASON MELISSA A. TALLEY NANCY L. MUNNIKHUYSEN CHARLES HOWARD MITCHELLBETTY B. MITCHELL CHARLES DAVIDMITCHELLLYNORA G. MITCHELL 87 0 860 85 0 840 830 8 2 0 8 1 4 81 4 870 860 850 840 830 8 2 0 81 4 81 4 816 850 840 83 0 820 816 816 816 8 4 0 8 3 0 830 820 82 0 818 818 81 4 B-01 B-02 B-03 B-08 B-07 B-04 B-05 B-06 Sc a l e F o r M i c r o f i l m i n g In c h e s Mi l l i m e t e r s no.date descriptionby 1 1312111098765432 I H G F E D C B A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file ckd J. STOUT C. YOW FEBRUARY 2026 J. STOUT 15 SNOW CREEK WETLAND MITIGATION SITE Burns & McDonnell Engineering Co, Inc. 110 FRANKLIN RD SE SUITE 700 ROANOKE, VA 24011 816-333-9400 LICENSEE NO. 0411001221 CHRIS YOW CIVIL ENGINEER License No. 0402052534 186472 C-001 EXISTING CONDITIONS EX DELINEATED WETLAND N 0 SCALE IN FEET 100'200' SNO W C R E E K UT T O S N O W C R E E K Soil Boring Locations Point # 1 2 3 4 5 6 7 8 Northing 3473425.32 3473471.09 3473611.57 3473581.05 3473698.93 3473722.08 3473823.97 3473824.49 Easting 11119235.44 11119112.29 11119151.03 11119275.70 11119290.01 11119184.48 11119167.78 11119330.83 Description B-01 B-02 B-03 B-08 B-07 B-04 B-05 B-06 1 HSG B 1 HSG B 2 HSG B 3 HSG B 3 HSG B 3 HSG B 3 HSG B 3 HSG B 4 HSG C 5 HSG B 6 HSG B 5 HSG B EXISTING 65.4 LF 60" CMP CULVERT LEGEND: MINNIEVILLE LOAM WINTERGREEN LOAM CLIFFORD FINE SANDY LOAM COLESCREEK -DELANCO COMPLEX CLIFFORD -HICKORYKNOB COMPLEX COMUS -MAGGODEE -ELSINBORO COMPLEX EXISTING FLOWLINE EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR FEMA FLOODPLAIN SOIL TYPE BOUNDARY EXISTING BENCHMARK 1 2 3 4 5 6 100-YR FLOODPLAIN 3 Z:\CLIENTS\ENS\MTNVALLEYPIP\186472_MITIGATIONBANK\DESIGN\CADD\DWGS\PROD DWGS\EXISTING CONDITIONS.DWG SAVED BY:JCSTOUT C-002 WATER BUDGET WATER BUDGET NARRATIVE SNOW CREEK MITIGATION SITE I.Introduction The water budgets on this sheet were prepared to determine the nature of the water regime expected in this constructed wetland system to assist in vegetation selection, to develop confidence that the prerequisite hydrology necessary to support a wetland will be achieved, to predict system modifications that will be required as the contributing watershed develops over time, and to determine which elements of the design are critical to the success of the project. The water budgets were prepared for the aforementioned wetland system using the methodologies described herein to calculate the water budget using Excel. The proposed wetland area is located east of Airport Rd. and west of Snow Creek in Franklin County, VA. The site is primarily grassland with gentle slopes across the site. The site is a natural low point and will be used to create a wetland mitigation bank for the MVP Southgate Pipeline. The creation of wetland habitat will help increase the storage capacity of the surrounding watershed, increase habitat diversity, and increase biodiversity in the area. Approximately 11.27 acres of open grassland and wetland are proposed for the site. A typical water budget is presented to demonstrate the expected hydroperiod for the typical dry, normal, and wet years for the proposed wetland areas. This typical water budget uses conservative estimates of the various parameters and depicts the expected variation in the hydroperiod for these restored wetland areas. Many of these cells will have more hydrologic inputs and/or slower infiltration rates in the underlying materials than this typical water budget. II.Primary Components Quantified A.Inputs 1. Precipitation Precipitation has been quantified from the Martinsville Filter Plant NOAA station for the past 61 years of available data. Excel was used to determine the typical dry, normal, and wet years by evaluating the 30th, 50th, and 70th percentile annual rainfall. 1984 was determined to be the 30th percentile or dry year, 1952 was the 50th percentile or normal year, and 1993 was the 70th percentile or the wet year. Precipitation falling directly on the constructed wetland area comprises this input factor. 2. Surface Runoff Surface runoff was calculated using the SCS runoff curve number method. Q=(P-Ia)2/((P-Ia)+S) where Q=runoff (in.) P=rainfall (in.) S=potential maximum retention after runoff begins (in.) Ia=initial abstraction (in.) and S=(1000/Curve Number)-10 Ia=0.2*S 3. Groundwater Infiltration Groundwater infiltration is probable for the site but is not considered to present the most conservative water budget possible. The water budget indicates target water levels are achieved despite the conservative approach. 4. Overbank Flow Snow Creek runs adjacent to the east site of the proposed wetland but overflow from the creek is not considered in the water budget for simplicity and to provide a more conservative water budget. B.Outputs 1. Evapotranspiration Potential evapotranspiration was estimated using the Thornthwaite forumla for monthly PET in Excel. Et =1.6*(10*Ta/I)a where Et =PET in cm/mo Ta=mean monthly air temperature (Centigrade) I=monthly heat index I=∑(Ta/5)1.5 for twelve months, and a=0.49+0.0179*I-0.0000771*I2+0.000000675*I3 The formula is for a standard month of 30 days of daylight and must be adjusted for latitude and month (Dun and Leopold 1978) by a correction factor provided by a table developed for use with this formula. Data for the PET was sourced from the the Martinsville Filter Plant NOAA station. 2. Groundwater Exfiltration The groundwater exfiltration output is the water lost due to the permeability of the soil materials underlying the constructed wetland area. Data suggested by the NRCS Soil Survey Manual indicate highly permeable soils in the area with saturated hydraulic conductivity of 9 micrometer/s. To remain conservative in our estimate, a saturated hydraulic conductivity of 0.07 micrometers/s or 0.01 in/hr was used to calculate groundwater exfiltration. Converted to a loss rate in in/mo, k=0.01 in/hr is equal to: 0.01 in/hr x 24 hr/d x 30 d/mo =7.2 in/mo This approach is conservative as it uses Darcy's Law with 1-foot of head and a 1-foot restrictive layer. In actuality, the head is rarely more than a few inches. 3. Outflow The maximum water elevations of the constructed wetland area will occur whenever the water level reaches the top of the wetland boundary. When this occurs, water will outflow from the wetland to Snow Creek and the surrounding area. 4. Water Level Baseline The water level baseline for the water budget was assumed to be at max capacity of the wetland to simplify storage calculations. By assuming the wetland to be at maximum capacity, we remain conservative in our water budget because the wetland will have no additional storage capacity and will overflow unless storage capacity is gained in the previous months water budget. Sc a l e F o r M i c r o f i l m i n g In c h e s Mi l l i m e t e r s no.date descriptionby 1 1312111098765432 I H G F E D C B A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file ckd J. STOUT C. YOW FEBRUARY 2026 J. STOUT 15 SNOW CREEK WETLAND MITIGATION SITE Burns & McDonnell Engineering Co, Inc. 110 FRANKLIN RD SE SUITE 700 ROANOKE, VA 24011 816-333-9400 LICENSEE NO. 0411001221 CHRIS YOW CIVIL ENGINEER License No. 0402052534 186472 4 Z:\CLIENTS\ENS\MTNVALLEYPIP\186472_MITIGATIONBANK\DESIGN\CADD\DWGS\PROD DWGS\WATER BUDGET.DWG SAVED BY:JCSTOUT 820 825 830 835 839 82 0 8 2 5 83 0 835 840 830 817 816 8 1 8 815 81 5 81 5 818 816 8 1 6 816 816 818 816 819 815 814 815 815 815 816 817 816 815 810 820 8 1 8 8 1 5 820 824 817 821 823 A A B C B C Sc a l e F o r M i c r o f i l m i n g In c h e s Mi l l i m e t e r s no.date descriptionby 1 1312111098765432 I H G F E D C B A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file ckd J. STOUT C. YOW FEBRUARY 2026 J. STOUT 15 SNOW CREEK WETLAND MITIGATION SITE Burns & McDonnell Engineering Co, Inc. 110 FRANKLIN RD SE SUITE 700 ROANOKE, VA 24011 816-333-9400 LICENSEE NO. 0411001221 CHRIS YOW CIVIL ENGINEER License No. 0402052534 186472 C-101 GRADING PLAN N WATER CONTROL STRUCTURE SEE SHEET C-501 EXISTING WETLAND BOUNDARY WETLAND BREAKDOWN WETLAND ENHANCEMENT: 3.38 ACRES WETLAND CREATION: 2.88 ACRES UPLAND BUFFER: 5.11 ACRES CUT: 7140 CU. YDS. FILL: 2800 CU. YDS. NET CUT: 4340 CU. YDS. 0 SCALE IN FEET 50'100' SNOW CREEK 5 Z:\CLIENTS\ENS\MTNVALLEYPIP\186472_MITIGATIONBANK\DESIGN\CADD\DWGS\PROD DWGS\GRADING PLAN 2.0.DWG SAVED BY:JCSTOUT El e v a t i o n Station ALIGNMENT A PROFILE 810 820 830 840 850 810 820 830 840 850 -1+00 0+00 1+00 2+00 3+00 4+00 5+00 -1+00 0+00 1+00 2+00 3+00 4+00 5+00 El e v a t i o n Station ALIGNMENT B PROFILE 810 820 830 840 850 810 820 830 840 850 -1+00 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 -1+00 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 El e v a t i o n Station ALIGNMENT C PROFILE 810 820 830 840 850 810 820 830 840 850 -1+00 0+00 1+00 2+00 3+00 4+00 5+00 6+00 -1+00 0+00 1+00 2+00 3+00 4+00 5+00 6+00 Sc a l e F o r M i c r o f i l m i n g In c h e s Mi l l i m e t e r s no.date descriptionby 1 1312111098765432 I H G F E D C B A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file ckd J. STOUT C. YOW FEBRUARY 2026 J. STOUT 15 SNOW CREEK WETLAND MITIGATION SITE Burns & McDonnell Engineering Co, Inc. 110 FRANKLIN RD SE SUITE 700 ROANOKE, VA 24011 816-333-9400 LICENSEE NO. 0411001221 CHRIS YOW CIVIL ENGINEER License No. 0402052534 186472 C-102 5 WETLAND PROFILES N LEGEND: EXISTING GRADE FUTURE GRADE 0 SCALE IN FEET 50'100' 6 Z:\CLIENTS\ENS\MTNVALLEYPIP\186472_MITIGATIONBANK\DESIGN\CADD\DWGS\PROD DWGS\GRADING PLAN 2.0.DWG SAVED BY:JCSTOUT 0 SCALE IN FEET 100'200' 0 20 ' 10 ' SC A L E I N F E E T © 2025 Microsoft Corporation © 2025 Maxar ©CNES (2025) Distribution Airbus DS 87 0 860 85 0 840 830 8 2 0 8 1 4 81 4 870 860 850 840 830 8 2 0 81 4 81 4 816 850 840 83 0 820 816 816 816 8 4 0 8 3 0 830 820 82 0 818 818 81 4 Sc a l e F o r M i c r o f i l m i n g In c h e s Mi l l i m e t e r s no.date descriptionby 1 1312111098765432 I H G F E D C B A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file ckd J. STOUT C. YOW FEBRUARY 2026 J. STOUT 15 SNOW CREEK WETLAND MITIGATION SITE Burns & McDonnell Engineering Co, Inc. 110 FRANKLIN RD SE SUITE 700 ROANOKE, VA 24011 816-333-9400 LICENSEE NO. 0411001221 CHRIS YOW CIVIL ENGINEER License No. 0402052534 186472 C-301 PLANTING PLAN LEGEND: SNOW CREEK N 0 SCALE IN FEET 100'200' UPLAND BUFFER SEED/PLANT FORESTED WETLAND SEED/PLANT UT T O S N O W C R E E K 7 Z:\CLIENTS\ENS\MTNVALLEYPIP\186472_MITIGATIONBANK\DESIGN\CADD\DWGS\PROD DWGS\PLANTING PLAN.DWG SAVED BY:JCSTOUT Sc a l e F o r M i c r o f i l m i n g In c h e s Mi l l i m e t e r s no.date descriptionby 1 1312111098765432 I H G F E D C B A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file ckd J. STOUT C. YOW FEBRUARY 2026 J. STOUT 15 SNOW CREEK WETLAND MITIGATION SITE Burns & McDonnell Engineering Co, Inc. 110 FRANKLIN RD SE SUITE 700 ROANOKE, VA 24011 816-333-9400 LICENSEE NO. 0411001221 CHRIS YOW CIVIL ENGINEER License No. 0402052534 186472 C-302 PLANTING SCHEDULE PFO Area Planting and Seeding Notes: 1.Substitutions for selected species based upon availability shall be requested in writing to engineer, documenting lack of availability. 2.Wildlife value indicator is based on the Virginia Department of Conservation and Recreation (DCR)'s brochure: "Native Plants for Conservation, Restoration & Landscaping: Virginia Piedmont Region." Species with "-" are regionally native but not included on brochure. 3.The planted trees and shrubs shall be randomly spaced and species mixed throughout the planting areas. 4.Container rates and quantities shown for one gallon size. For purposes of substitution, two tubelings are the equivalent of one 1-gallon. 5.All seeding rates are expressed in pounds of pure live seed (PLS). 8 Z:\CLIENTS\ENS\MTNVALLEYPIP\186472_MITIGATIONBANK\DESIGN\CADD\DWGS\PROD DWGS\PLANTING SCHEDULE.DWG SAVED BY:JCSTOUT © 2025 Microsoft Corporation © 2025 Maxar ©CNES (2025) Distribution Airbus DS LOD L O D L O D LOD LOD LOD LO D LO D LO D LOD LO D LO D LO D L O D LOD LOD LOD LO D LOD LOD LOD LOD LOD LO D LO D L O D LO D LO D LO D LO D LO D LOD LOD LOD L O D PS PS TS TS TS TS PS Sc a l e F o r M i c r o f i l m i n g In c h e s Mi l l i m e t e r s no.date descriptionby 1 1312111098765432 I H G F E D C B A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file ckd J. STOUT C. YOW FEBRUARY 2026 J. STOUT 15 SNOW CREEK WETLAND MITIGATION SITE Burns & McDonnell Engineering Co, Inc. 110 FRANKLIN RD SE SUITE 700 ROANOKE, VA 24011 816-333-9400 LICENSEE NO. 0411001221 CHRIS YOW CIVIL ENGINEER License No. 0402052534 186472 C-401 9 SITE ACCESS AND ESC PLAN LEGEND: N 0 SCALE IN FEET 100'200' LIMITS OF DISTURBANCE ACCESS PATH SILT FENCE LAYDOWN AREA TIMBER MATTING ROCK CHECK DAM PERMANENT BARBED WIRE FENCE PERMANENT SEEDING TEMPORARY SEEDING TEMPORARY FENCE UT T O S N O W C R E E K LOD PS TS TEMPORARY SILT FENCE C-PCM-04-2B TEMPORARY LAYDOWN AREA SEE DETAIL ON SHEET C-501 TEMPORARY SOIL STOCKPILE AREA TEMPORARY CONSTRUCTION ENTRANCE C-SCM-03-1 PROPOSED TEMPORARY ACCESS PATH PERMANENT BARBED WIRE FENCE 12' (TYP) 10' ACCESS GATE (TYP) TIMBER MATTING C-ENV-06-1 & C-ENV-06-2 TEMPORARY ROCK CHECK DAM C-SCM-07-1 TEMPORARY LAYDOWN AREA SEE DETAIL ON SHEET C-501 Z:\CLIENTS\ENS\MTNVALLEYPIP\186472_MITIGATIONBANK\DESIGN\CADD\DWGS\PROD DWGS\ESC PLAN.DWG SAVED BY:JCSTOUT SNOW CREEK PROTECTED AREA - NOT TO BE DISTURBED EXISTING ACCESS GATE 12' MIN. EXISTING GROUND B 70' MIN. 10' MIN. A 10' MIN. SECTION B-B 6'-7" SECTION A-A PLAN VIEW 3" MIN. 3" MIN. B 70' MIN. 6" MIN.A SIDE ELEVATION * 3' 12' MIN. 10' MIN. C-SCM-03-1 STONE CONSTRUCTION ENTRANCE SOURCE: VA. DSWC, MD ESC STDSv1.1 REINFORCED CONCRETE DRAIN SPACE FILTER CLOTH * MUST EXTEND FULL WIDTH OF INGRESS AND EGRESS OPERATION POSITIVE DRAINAGE TO SEDIMENT TRAPPING DEVICE VDOT #1 COURSE AGGREGATE EXISTING PAVEMENT WASHRACK (OPTIONAL) MOUNTABLE BERM (OPTIONAL)FILTER CLOTH 5:1 EXISTING PAVEMENT SHEET FLOW INSTALLATION (PERSPECTIVE VIEW) POINTS A SHOULD BE HIGHER THAN POINT B. DRAINAGEWAY INSTALLATION (FRONT ELEVATION) A B FLOW A 3'MAX. FLOW 4" FLOW 1.SET THE STAKES 3.STAPLE THE FILTER MATERAIL TO STAKES AND EXTENT IT INTO THE TRENCH. 4.BACKFILL AND COMPACT THE EXCAVATED SOIL. 2.EXCAVATE A 4"x4" TRENCH UPSLOPE ALONG THE LINE OF STAKES. FLOW C-PCM-04-2B CONSTRUCTION OF SILT FENCE WITHOUT WIRE SUPPORT FAB. BARRIERS, SHERWOOD & WYANTv1.1 SOURCE: ADAPTED FROM STRAW & C-ENV-06-2 STABLE WETLAND CROSSING LAYOUT DETAIL SOURCE: VDEQ 1992v1.1 PLAN VIEW SIDE VIEW WETLAND EXISTING GRADE ED G E O F R O W ED G E O F R O W EQUIPMENT PADS 16' TO 20' TYP. EXISTING PIPELINE WETLAND LIMIT ED G E O F R O W WETLAND LIMIT WATERBARS OR SLOPE BREAKER ED G E O F R O W 3' TO 4' TYP. 50' EXISTING ROW EQUIPMENT PADS EXISTING PIPELINE C-ENV-06-1 WOODEN WETLAND CROSSING DETAIL SOURCE: VDEQ 1992v1.1 DETAIL A WOODEN CURBING OR COMPOST FILTER SOCK WRAPPED IN GEOTEXTILE GEOTEXTILE FABRIC CONNECT LOOPS WITH 3/16" CABLE CLAMPS DETAIL A 3/16" GALVANIZED STEEL CABLE WOODEN CURBING OR COMPOST FILTER SOCK WRAPPED IN GEOTEXTILE FABRIC BOTH SIDES GEOTEXTILE FABRIC 2' 2' 10 F T . M I N . DIRE C T I O N OF T R A V E L 2-10 ACRES OF DRAINAGE AREA C-SCM-07-1 ROCK CHECK DAM SOURCE: VA. DSWCv1.1 FLOW VDOT #1 COARSE AGGREGATE CLASS I RIPRAP 2: 1 3' 3' FILTER CLOTH (OPTIONAL) 6" (DOWNSTREAM VIEW) Sc a l e F o r M i c r o f i l m i n g In c h e s Mi l l i m e t e r s no.date descriptionby 1 1312111098765432 I H G F E D C B A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file ckd J. STOUT C. YOW FEBRUARY 2026 J. STOUT 15 SNOW CREEK WETLAND MITIGATION SITE Burns & McDonnell Engineering Co, Inc. 110 FRANKLIN RD SE SUITE 700 ROANOKE, VA 24011 816-333-9400 LICENSEE NO. 0411001221 CHRIS YOW CIVIL ENGINEER License No. 0402052534 186472 C-402 ESC DETAILS 10 Z:\CLIENTS\ENS\MTNVALLEYPIP\186472_MITIGATIONBANK\DESIGN\CADD\DWGS\PROD DWGS\ESC DETAILS.DWG SAVED BY:JCSTOUT C-ENV-13-1 WETLAND CELL SEDIMENT TRAP LAYOUT SOURCE: WETLAND STUDIES AND SOLUTIONS, INC. 2020v1.1 WETLAND BERM TEMPORARY STONE WEIR OUTLET (PLAN VIEW) WETLAND BERM TOE OF SLOPE PERMANENT STONE WEIRFL O W OUTLET (SECTION VIEW) * ALTERNATIVELY, THE CELL MAY BE EXCAVATED 6" (OR GREATER) INTO IN-SITU SOILS WETLAND BERM* PERMANENT STONE WEIR COARSE AGGREGATE COARSE RIPRAP EXISTING GRADE * FLOW 1' 5:1 2 : 1 1'9' 2:15:1 WETLAND CELL FINISHED GRADE C-ENV-12-1 WETLAND WEIR OUTLET SOURCE: ANGLER ENVIRONMENTALv1.1 WEIR OUTLET NOT TO SCALE THE SIZE, LOCATION AND FREQUENCY OF STRUCTURE WILL BE BASED ON SITE CONDITIONS AND WILL BE DESIGNATED TO MAINTAIN NON-EROSIVE DISCHARGE VELOCITIES. 9" TOPSOIL SLO P E V A R I A B L E GRASSED VEGETATION VARIABLE WETLAND CELL BENCH CLAY WITH HYDRAULIC CONDUCTIVITY SHALL BE 1 X 10^ 6 CM/S OR LESS. GEOTEXTILE FABRIC ARMORFLEX MATTING* VARIABLE ARMORFLEX MATTING* GEOTEXTILE FABRIC WETLAND OR UNDISTURBED PERIMETERWETLAND VARIABLE COMPACTED FILL CLAY WITH HYDRAULIC CONDUCTIVITY SHALL BE 1 X 10^ -6 CM/S OR LESS BENTOMAT MAY BE SUBSTITUTED FOR CLAY CORE AND KEY * OR OTHER EROSION CONTROL MATTING GRASSED VEGETATION S L O P E V A R I A B L E Sc a l e F o r M i c r o f i l m i n g In c h e s Mi l l i m e t e r s no.date descriptionby 1 1312111098765432 I H G F E D C B A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file ckd J. STOUT C. YOW FEBRUARY 2026 J. STOUT 15 SNOW CREEK WETLAND MITIGATION SITE Burns & McDonnell Engineering Co, Inc. 110 FRANKLIN RD SE SUITE 700 ROANOKE, VA 24011 816-333-9400 LICENSEE NO. 0411001221 CHRIS YOW CIVIL ENGINEER License No. 0402052534 186472 C-403 ESC DETAILS 2 11 Z:\CLIENTS\ENS\MTNVALLEYPIP\186472_MITIGATIONBANK\DESIGN\CADD\DWGS\PROD DWGS\ESC DETAILS.DWG SAVED BY:JCSTOUT Sc a l e F o r M i c r o f i l m i n g In c h e s Mi l l i m e t e r s no.date descriptionby 1 1312111098765432 I H G F E D C B A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file ckd J. STOUT C. YOW FEBRUARY 2026 J. STOUT 15 SNOW CREEK WETLAND MITIGATION SITE Burns & McDonnell Engineering Co, Inc. 110 FRANKLIN RD SE SUITE 700 ROANOKE, VA 24011 816-333-9400 LICENSEE NO. 0411001221 CHRIS YOW CIVIL ENGINEER License No. 0402052534 186472 C-501 DETAILS FLOW SN O W C R E E K A A B B PLAN A-A B-B NON-WOVEN FABRIC GRAVEL FILTER EXISTING GROUND COIR MATTING STAKE STAKE GRAVEL FILTER EXISTING DITCH WATER CONTROL STRUCTURE DETAIL BOULDER 12 Z:\CLIENTS\ENS\MTNVALLEYPIP\186472_MITIGATIONBANK\DESIGN\CADD\DWGS\PROD DWGS\ESC DETAILS.DWG SAVED BY:JCSTOUT LAYDOWN AREA DETAIL 12" #57 STONE FLASHBOARD RISERS © 2025 Microsoft Corporation © 2025 Maxar ©CNES (2025) Distribution Airbus DS 87 0 860 85 0 840 830 8 2 0 8 1 4 81 4 870 860 850 840 830 8 2 0 81 4 81 4 816 850 840 83 0 820 816 816 816 8 4 0 8 3 0 830 820 82 0 818 818 81 4 Sc a l e F o r M i c r o f i l m i n g In c h e s Mi l l i m e t e r s no.date descriptionby 1 1312111098765432 I H G F E D C B A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file ckd J. STOUT C. YOW FEBRUARY 2026 J. STOUT 15 SNOW CREEK WETLAND MITIGATION SITE Burns & McDonnell Engineering Co, Inc. 110 FRANKLIN RD SE SUITE 700 ROANOKE, VA 24011 816-333-9400 LICENSEE NO. 0411001221 CHRIS YOW CIVIL ENGINEER License No. 0402052534 186472 C-601 CREDIT ANALYSIS SUMMARY LEGEND: N 0 SCALE IN FEET 100'200' UPLAND BUFFER WETLAND ENHANCEMENT WETLAND CREATION PERMANENT BARBED WIRE FENCE SNOW CREEK TOP OF BANK SNOW CREEK UT T O S N O W C R E E K 13 Z:\CLIENTS\ENS\MTNVALLEYPIP\186472_MITIGATIONBANK\DESIGN\CADD\DWGS\PROD DWGS\CREDIT ANALYSIS SUMMARY.DWG SAVED BY:JCSTOUT INSTALL CONSERVATION EASEMENT SIGNAGE ON PERMANENT BARBED WIRE FENCE EVERY 50LF Sc a l e F o r M i c r o f i l m i n g In c h e s Mi l l i m e t e r s no.date descriptionby 1 1312111098765432 I H G F E D C B A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file ckd J. STOUT C. YOW FEBRUARY 2026 J. STOUT 15 SNOW CREEK WETLAND MITIGATION SITE Burns & McDonnell Engineering Co, Inc. 110 FRANKLIN RD SE SUITE 700 ROANOKE, VA 24011 816-333-9400 LICENSEE NO. 0411001221 CHRIS YOW CIVIL ENGINEER License No. 0402052534 186472 C-602 WETLAND VALUE AND FUNCTION SCORE SHEETS PRE-CONSTRUCTION POST-CONSTRUCTION 14 Z:\CLIENTS\ENS\MTNVALLEYPIP\186472_MITIGATIONBANK\DESIGN\CADD\DWGS\PROD DWGS\WETLAND VALUE AND FUNCTION SCORE SHEETS.DWG SAVED BY:JCSTOUT © 2025 Microsoft Corporation © 2025 Maxar ©CNES (2025) Distribution Airbus DS 87 0 860 85 0 840 830 8 2 0 8 1 4 81 4 870 860 850 840 830 8 2 0 81 4 81 4 816 850 840 83 0 820 816 816 816 8 4 0 8 3 0 830 820 82 0 818 818 81 4 Point Table Point # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Northing N36° 51' 22.98" N36° 51' 24.35" N36° 51' 22.03" N36° 51' 23.37" N36° 51' 24.71" N36° 51' 25.53" N36° 51' 27.53" N36° 51' 21.40" N36° 51' 22.74" N36° 51' 24.08" N36° 51' 25.42" N36° 51' 26.24" N36° 51' 19.93" N36° 51' 20.76" N36° 51' 22.10" N36° 51' 23.56" N36° 51' 24.97" N36° 51' 25.85" N36° 51' 26.76" Easting W79° 44' 40.10" W79° 44' 39.67" W79° 44' 39.63" W79° 44' 38.84" W79° 44' 38.05" W79° 44' 37.06" W79° 44' 36.52" W79° 44' 37.96" W79° 44' 37.17" W79° 44' 36.38" W79° 44' 35.59" W79° 44' 35.87" W79° 44' 36.70" W79° 44' 36.29" W79° 44' 35.50" W79° 44' 35.03" W79° 44' 34.42" W79° 44' 34.34" W79° 44' 34.80" Description MW1 MW2 MW3 MW4 MW5 MW6 MW7 MW8 MW9 MW10 MW11 MW12 MW13 MW14 MW15 MW16 MW17 MW18 MW19 MW1 MW2MW3 MW4 MW5 MW6 MW7 MW8 MW9 MW10 MW11 MW12 MW13 MW14 MW15 MW16 MW17 MW18 MW19 Sc a l e F o r M i c r o f i l m i n g In c h e s Mi l l i m e t e r s no.date descriptionby 1 1312111098765432 I H G F E D C B A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file ckd J. STOUT C. YOW FEBRUARY 2026 J. STOUT 15 SNOW CREEK WETLAND MITIGATION SITE Burns & McDonnell Engineering Co, Inc. 110 FRANKLIN RD SE SUITE 700 ROANOKE, VA 24011 816-333-9400 LICENSEE NO. 0411001221 CHRIS YOW CIVIL ENGINEER License No. 0402052534 186472 C-603 MONITORING WELL AND PHOTO MONITORING LOCATIONS LEGEND: N 0 SCALE IN FEET 100'200' UPLAND BUFFER WETLAND MITIGATION PERMANENT BARBED WIRE FENCE SNOW CREEK TOP OF BANK MONITORING WELL LOCATION SNOW CREEK UT T O S N O W C R E E K 15 Z:\CLIENTS\ENS\MTNVALLEYPIP\186472_MITIGATIONBANK\DESIGN\CADD\DWGS\PROD DWGS\MONITORING WELL MAP.DWG SAVED BY:JCSTOUT NOTE: PHOTO STATIONS ARE LOCATED IN SAME LOCATION AS THE MONITORING WELLS. SOIL TEST PITS ARE LOCATED 10-30 FEET FROM WELLS, SPECIFIC LOCATIONS ARE AT THE DISCRETION OF THE MONITORING FIELD TEAM.