Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NCG030246_Tier III Action Plan and DEQ Response_2025052028
Cross, Kelsie From: Cross, Kelsie Sent: Wednesday, May 28, 2025 3:54 PM To: SmithC2@corning.com Cc: AdamsJH@Corning.com; EdgertonRS@Corning.com; miltonla@corning.com; Eplin, Jerry W Subject: FW: [External] Corning Optical Communications - Hickory NC Cable Plant - Stormwater Exceedance Action Plan Attachments: CAR250078 Corning Hickory COD Action Plan.pdf Good afternoon, Carl, NCDEQ has received and approves of your proposed action plan relating to COD exceedances at Outfall#3. Please let us know if you require our assistance. Sincerely, Kelsie Cross Engineer 1 North Carolina Department of Environmental Quality Division of Energy, Mineral, and Land Resources Office: (704)235-2143 1 Cell: (980)435-7852 Email: kelsie.crossa-deg.nc.gov Physical and Mailing Address: 610 E. Center Ave. Suite 301 Mooresville, NC 28115 DEm a�+r�."9�!Quip-FW-K Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties From: Eplin,Jerry W<jerry.eplin@deq.nc.gov> Sent:Thursday, April 17, 2025 3:27 PM To: Cross, Kelsie<kelsie.cross@deq.nc.gov> Subject: FW: [External] Corning Optical Communications- Hickory NC Cable Plant-Stormwater Exceedance Action Plan For review and response. Jerry W. Eplin, PE Regional Engineer North Carolina Department of Environmental Quality 1 Division of Energy, Mineral, and Land Resources 610 E. Center Ave. Suite 301 Mooresville, NC 28115 Office: (704) 235-2147 jerry.eplina-deg.nc.gov {}�j;innir�i nl Enyronniraiial D,- EQN&7,A- qkiahkv Ema/l correspondence to and from this address is subject to the North Caro/Ina Public Records Law and may be disclosed to third parties From: Smith, Carl (WL) <SmithC2@corning.com> Sent:Thursday, April 17, 2025 3:16 PM To: Eplin,Jerry W<ierry.eplin@deg.nc.gov> Cc:Adams,Jennifer H <AdamsJH@Corning.com>; Edgerton, Ronica S<EdgertonRS@Corning.com>; Milton, Lorissa A <miltonla@corning.com> Subject: [External] Corning Optical Communications- Hickory NC Cable Plant-Stormwater Exceedance Action Plan CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Mr. Eplin: The Corning Optical Communications, LLC facility located at 116423 d St SE, Hickory, NC 28602 currently operates under General Permit No. NCG030000, as evidenced by Certificate of Coverage No. NCG030246. This email is regarding a follow- up action plan regarding a COD benchmark exceedance for Outfall#3. As indicated in previous communications on 04/02/25, the site is currently under Tier III monitoring requirements due to past exceedances outlined in the table below. HMTC COD Benchmark Exceedances Date Sample Taken Lab Result 04/05/2022 148 mg/L 05/06/2022 132 mg/L 10/12/2022 142 mg/L 03/05/2025 130 mg/L Please see the action plan attached for your reference and approval. 2 Sincerely, Carl Smith HMTC Plant Manager Office: (828) 901-4009 Cell: (828)446-7440 Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties by an authorized state official. 3 Prepared for Corning Optical Communications, LLC 1164 23rd Street Southeast Hickory, North Carolina 28602 NPDES ACTION PLAN - CORNING OPTICAL COMMUNICATIONS HICKORY MANUFACTURING AND TECHNOLOGY CENTER HICKORY, NORTH CAROLINA Prepared by Geosyntecc> consultants Geosyntec Consultants of NC,P.C. Geosyntec Consultants of NC, P.C. 414 Chestnut Street, Suite 102 Wilmington NC 28401 Project Number GN11195 April 2025 Geosynte& consultants GeoWn[ec Consultants of NC,P.C. TABLE OF CONTENTS 1. Introduction........................................................................................................... 1 1.1. Site Description and Operations.................................................................. 1 1.2. Stormwater Drainage Areas......................................................................... 1 1.3. Regulatory Framework................................................................................2 2. Documentation of Exceedances............................................................................3 2.1. SDO 3 Analytical Monitoring......................................................................3 3. Site Inspection and Inspection Report..................................................................4 4. Stormwater Management Procedures...................................................................5 4.1. Standard Operating Procedures ...................................................................5 4.1.1. Spill Prevention and Response.......................................................5 4.1.2. Employee Training.........................................................................5 4.1.3. Visual Inspections...........................................................................6 4.1.4. Record Keeping and Reporting......................................................6 4.1.5. Sediment and Erosion Control........................................................7 4.1.6. Filtration.........................................................................................8 4.2. Housekeeping Procedures............................................................................ 8 5. Identification of Sources.......................................................................................9 5.L Source Investigation ....................................................................................9 6. Remedy Actions.................................................................................................. 11 6.1. Completed Actions .................................................................................... 11 6.2. Potential Future Remedy Actions.............................................................. 11 7. Monitoring Plan.................................................................................................. 13 7.1. Monitoring Schedule.................................................................................. 13 7.2. Sample Procedures..................................................................................... 13 7.2.1. Identifying a Qualifying Storm Event.......................................... 13 7.2.2. Sample Collection and Handling.................................................. 13 7.2.3. Laboratory Analyses..................................................................... 14 8. CONCLUSIONS................................................................................................. 15 9. REFERENCES ................................................................................................... 16 GN11195/CAR250078 Corning Hickory COD Action Plan i April 2025 Geosynte& consultants Geosyntec Consultants of NC,P.C. TABLE OF CONTENTS (Continued) LIST OF TABLES Table 1 Stormwater Discharge Outfall Analytical Results LIST OF FIGURES Figure 1 Site Location Map Figure 2 Site Layout Map Figure 3 Stormwater Features Map Figure 4 SD03 Analytical Results LIST OF APPENDICES Appendix A NCG030000 Permit Appendix B Photolog Appendix C Inspection Checklist GN11195/CARCAR250078 Corning Hickory COD Action Plan ii April 2025 Geosynte& consultants Geosyn[ec Consultants of NC,P.C. 1. INTRODUCTION Geosyntec Consultants of NC, P.C. (Geosyntec) has prepared this Action Plan on behalf of Corning Optical Communications,LLC(Corning)for the Hickory Manufacturing and Technology Center(Site)in Hickory,North Carolina(Figure 1)for submittal to the North Carolina Department of Environmental Quality (NCDEQ) Division of Energy, Mineral, and Land Resources (the Division). The Action Plan for the Site was prepared in accordance with Section E-7 of the State of North Carolina National Pollutant Discharge Elimination System(NPDES) General Permit No. NCG030000 for Metal Fabrication. The purpose of the Action Plan is to document benchmark concentration exceedances associated with chemical oxygen demand (COD), describe observations made during the site inspection, and evaluate standard operating procedures and Site housekeeping practices, with the ultimate goal of identifying the source(s) of the exceedances and describing the actions to be taken to remedy the source(s) of the exceedances. 1.1. Site Description and Operations The Site consists of approximately 37.85 acres in Catawba County. The Site is bounded to the north by commercial/industrial businesses including Design Foundry (Furniture Manufacturer) and Von Drehle Corporation (Paper Distributor); to the east by an unnamed tributary of Clark Creek followed by several commercial properties; to the south by Design Master Furniture Inc; and to the west by McDonald Parkway SE, followed by Clark Creek and Martin Marietta Quarry (Figure 2). The primary function of the Site is the manufacturing of fiber optic communication cable. Structures on the Site include the Production Building, the Warehouse, the Metal Recycling area, and the Hazardous Materials Storage Shed. 1.2. Stormwater Drainage Areas Stormwater runoff from the Site discharges via five stormwater discharge outfalls (SDOs) which receive runoff from their corresponding drainage areas, as depicted in Figure 3. SDO 1 receives stormwater from Drainage Area 1, an approximately 3.4-acre area including the roof of the southeastern corner of the Production Building and the paved surface adjacent to the Production Building.Industrial activities in Drainage Area 1 include covered general storage,three uncovered municipal roll-off dumpsters,wooden reel storage, and limited steel reel storage. There is also frequent forklift activity in Drainage Area 1. SDO 2 receives stormwater from Drainage Area 2, an approximately 0.8-acre area including the Hazardous Materials Storage Shed, concrete pads adjacent to the Hazardous Materials Storage Shed, and surrounding paved areas. Industrial activities in Drainage Area 2 include wooden and steel reel storage and frequent forklift activity. GN11195/CAR250078 Coming Hickory COD Action Plan 1 April 2025 Geosynte& consultants GeoWn[ec Consultants of NC,P.C. SDO 3 receives stormwater from Drainage Area 3, an approximately 5.5-acre area including the roof of the northeastern corner of the Production Building, the southeast corner of the Warehouse, and the shed areas in the east-central portion of the Site, including the metal recycling shed. Industrial activities in Drainage Area 3 include wooden reel storage, temporary steel reel staging, metal recycling (stored under cover), and frequent forklift activity. SDO 4 receives stormwater from Drainage Area 4, an approximately 0.4-acre area comprised of the northeast roof section of the warehouse. SDO 5 receives stormwater from Drainage Area 5, an approximately 14.4-acre area including the west side of the warehouse, west production building roof drains, pervious and impervious areas surrounding the silos, transformers, chiller plants, the southwest side of the Site, and the pervious area making up the northwest corner of the property. Industrial activities in Drainage Area 5 primarily consist of wooden and steel reel storage and some forklift traffic. Routine sampling takes place at SDO 3 and SDO 5. SDO 3 has been granted Representative Outfall Status for SDO 1 and SDO 2, indicating that the stormwater discharges from SDOs 1 and 2 are substantially identical to SDO 3 and can be represented at SDO 3. Stormwater runoff to SDO 4 consists exclusively of rooftop drainage, which is a non-industrial source and therefore does not require monitoring. 1.3. Regulatory Framework Stormwater discharges from the Site are regulated by National Pollutant Discharge Elimination System (NPDES) Certificate of Coverage No. NCG030246 under the State of North Carolina General Permit No. NCG030000 for Metal Fabrication (NCG03, Appendix A). This covers the Site's standard industrial code (SIC) 3357, which includes establishments primarily engaged in drawing and insulating wire and cable of nonferrous metals, including manufacturing of insulated fiber optic cable. The Site has recently progressed to Tier Three Response status as a result of four or more benchmark exceedances of COD at SDO 3 under the current NCG03 permit that took effect on 1 July 2021. Under this permit, Section E-7(b) requires submittal of an Action Plan to the Division within 30 days of receiving results triggering Tier Three Response status. Results from the first sampling event in the permit term were received on 19 March 2025, therefore this Action Plan is being submitted to the Division on or prior to 19 April 2025. GN11195/CAR250078 Corning Hickory COD Action Plan 2 April 2025 Geosynte& consultants GeoWn[ec Consultants of NC,P.C. 2. DOCUMENTATION OF EXCEEDANCES The Site is currently in Tier Three status as a result of exceedances of COD at SDO 3. Tier Three monitoring status requires monthly monitoring and additional reporting. Table 1 presents the data observed at SDO 3 since July 2021 (the sampling period during the permit term). The benchmark for COD is 120 milligrams per liter(mg/L)per the current NCG03 permit.Because COD is the parameter for which exceedances have been observed at the Site, this Action Plan exclusively discusses COD. SDO 3 will remain in Tier Three monitoring status until three consecutive sampling events are below the benchmarks for COD or until otherwise relieved by the Division. 2.1. SDO 3 Analytical Monitoring Four COD exceedances have been recorded at SDO 3 between April 2022 and March 2025. Three of the exceedances occurred between April 2022 and October 2022. Since the October 2022 sampling event, COD concentrations were below the benchmark until the March 2025 sampling event. Figure 4 depicts the results of sampling throughout the sampling period. GN11195/CAR250078 Corning Hickory COD Action Plan 3 April 2025 Geosynte& consultants GeoWn[ec Consultants of NC,P.C. 3. SITE INSPECTION AND INSPECTION REPORT An inspection of Drainage Area 3 to evaluate potential sources of COD was conducted by Geosyntec representative Ms. Anna Brand, EI(Nc) on 7 April 2025, accompanied by Corning representative Ms.Lorissa Milton.Photos taken during the inspection are included in Appendix B. As part of the Drainage Area 3 inspection, Geosyntec looked for the following: a. Evidence of sediment or other COD sources on Site, including staining, sheen, erosion, odor, or sediment buildup b. Waste management/disposal areas c. Materials storage d. Heavy equipment usage and/or storage e. The status and condition of existing Best Management Practices (BMPs) f. General functions of the stormwater system, including conveyance structures. The Site Inspection Report is provided in Appendix C. Primary observations in Drainage Area 3 possibly contributing to COD included leafy debris and pollen around storm drain inlets, as well as woody debris pieces from wooden reel storage. In addition to inspecting the Site for possible sources of stormwater impacts, Geosyntec observed remedy actions that had been implemented at the time of the Site visit. Section 6 discusses the remedy actions that are currently implemented. GN11195/CAR250078 Corning Hickory COD Action Plan 4 April 2025 Geosynte& consultants GeoWn[ec Consultants of NC,P.C. 4. STORMWATER MANAGEMENT PROCEDURES 4.1. Standard Operating Procedures The standard operating procedures summarized in the following sections are described in detail in the Site's Stormwater Pollution Prevention Plan (SWPPP). 4.1.1. Spill Prevention and Response The Site has developed a Spill Prevention and Response Plan(SPRP) specific to stormwater. This plan includes an assessment of potential pollutant sources based on a materials inventory of the Site, emergency response procedures, recordkeeping, and reporting. Additional Site-specific spill response plans include the Hazardous Waste Contingency Plan and the Spill Prevention Control and Countermeasures Plan. All three plans are comprehensive and include all elements required for the Site's stormwater spill prevention and response plan. All spill response plans are available for review on-Site. Corning shall report significant spills to the Mooresville Division of Water Quality (DWQ) local Division of Energy, Mineral and Land Resources (DEMLR) Regional Office within 24 hours of the spill. Significant spills include releases of oil or hazardous substances in excess of reportable quantities under Section 311 of the Clean Water Act or Section 102 of CERCLA. Corning shall also report: a. Any oil spill of 25 gallons or more b. Any spill regardless of the amount that causes a sheen on surface waters c. Any oil spill regardless of the amount occurring within 100 feet of surface waters d. Any oil spill less than 25 gallons that cannot be cleaned up within 24 hours 4.1.2. Employee Training The purpose of a training program is to teach personnel at all levels of responsibility the components and goals of the SWPPP. When properly trained, personnel are more able to prevent spills,respond safely and effectively to an accident when one occurs, and recognize situations that could lead to stormwater contamination. The Pollution Prevention Team as well as other staff who may be expected to participate in responsibilities related to stormwater attend annual SWPPP training. Training addresses all parts of the SWPPP, including how and why tasks are implemented. The following topics are included: a. spill prevention and response procedures GN11195/CAR250078 Corning Hickory COD Action Plan 5 April 2025 Geosynte& consultants GeoWn[ec Consultants of NC,P.C. b. good housekeeping and pollution prevention procedures c. material management practices d. basics of water pollution laws Lorissa Milton,the leader of the Pollution Prevention Team,directs the training program. Training is provided on an annual basis at minimum and documented with a signature from each participant. The effectiveness of the training effort will be regularly evaluated by verifying with employees that information has been communicated effectively. 4.1.3. Visual Inspections Inspections of the Site and all stormwater systems are conducted at a minimum on a quarterly schedule (January-March, April-June, July-September, October-December). Qualified plant personnel(members of the Pollution Prevention Team) conduct the inspection. The inspection and any subsequent maintenance activities performed are documented by recording the date and time of inspection, the individual(s) making the inspection, and a narrative description of the Site's stormwater control systems, plant equipment and systems. The inspection includes the following, at a minimum: a. areas around equipment (e.g. pumps,pipes, pressure vessels, and release valves) b. material storage areas (e.g. silos, reels yard, and Hazardous Materials Storage Shed) c. materials handling areas (e.g. silos, loading/unloading areas) d. outdoor material processing areas (if any occurred) e. waste generation and storage areas (e.g. hazardous waste pad) f. areas where spills and leaks have occurred in the past g. stormwater management devices (e.g. storm drains, catch basins, etc.) The inspection of stormwater conveyances and controls and measures to be taken will be conducted to limit or prevent erosion associated with the stormwater system. 4.1.4. Record Keeping and Reporting Each measurement, sample,inspection,or maintenance activity performed or taken pursuant to the requirements of the NCG03 permit is kept on record as a part of the SWPPP for a minimum of five (5)years and is available to the Division upon request. GN11195/CAR250078 Corning Hickory COD Action Plan 6 April 2025 Geosynte& consultants GeoWn[ec Consultants of NC,P.C. The SWPPP is reviewed and updated on an annual basis in accordance with Section I-1 of the NCG03 permit. Monitoring results obtained during the previous monitoring period are summarized in a Discharge Monitoring Report (DMR) and are currently submitted via an online portal. DMRs are submitted to the Division within 30 days of receipt of the lab results or at the end of the monitoring period if the Site is reporting that there was no discharge. DMRs were submitted by mail and via an online portal prior to January 2022. 4.1.4.1. Bypass A bypass is considered the known diversion of storm water from any portion of a stormwater control Site including the collection system,which is not a designed or established operating mode for the Site. If Corning knows in advance of the need for a bypass, Corning will submit prior notice, if possible at least ten days before the date of the bypass, and include an evaluation of the anticipated quality and effect of the bypass. If the Site experiences an unanticipated bypass, Corning will submit notice to the Division within 24 hours of becoming aware of the unanticipated bypass. 4.1.4.2. 24-Hour Reporting Corning will report to the Division any noncompliance which may endanger health or the environment. Information will be provided orally within 24 hours from the time Corning became aware of the circumstances. A written submission shall be provided within five days of the time Corning becomes aware of the circumstances. 4.1.5. Sediment and Erosion Control Erosion is a process where soil and rock material is loosened and removed. Sedimentation occurs when soil particles are suspended in the surface runoff or wind and deposited in streams and other water bodies. Most down spouts from the buildings are either directly connected to the storm drain line or drain to catch basins over a concrete surface. By doing this, surface erosion is prevented and sediment in the stormwater is minimized. The ground surface surrounding the manufacturing building and storage area of the Site is mostly paved. Grass preserves the unpaved ground surface surrounding the production building and storage areas of the Site. GN11195/CAR250078 Corning Hickory COD Action Plan 7 April 2025 Geosynte& consultants GeoWn[ec Consultants of NC,P.C. 4.1.6. Filtration In an effort to reduce total suspended solids (TSS), metals, and other contaminants from entering the stormwater system, filters have been installed on select stormwater drains and curb inlets. These filters may be either above or below grade and use either coconut fibers or mesh liners to filter contaminants. The filters are cleaned or replaced as needed. 4.2. Housekeeping Procedures Preventive maintenance and good housekeeping are designed to maintain a clean, orderly Site. Preventive maintenance is the regular inspection and testing of plant equipment and operation systems. These inspections uncover conditions such as cracks or slow leaks, which could cause breakdowns or failures that result in discharges of chemicals to storm sewers or surface waters. The program prevents breakdowns and failures by adjustment, repair, or replacement of equipment. The Site's preventive maintenance program includes the following elements, as described in more detail in the SWPPP: a. Identification of equipment, system, and Site areas that should be inspected b. Schedule for periodic inspection or tests of these equipment and systems c. Appropriate and timely adjustment, repair, or replacement of equipment and systems d. Maintenance of complete records on inspections, equipment, and systems GN11195/CAR250078 Corning Hickory COD Action Plan 8 April 2025 Geosynte& consultants GeoWn[ec Consultants of NC,P.C. 5. IDENTIFICATION OF SOURCES In accordance with the requirements outlined in the tiered response actions, Corning evaluated possible causes of the benchmark value exceedances through Site reconnaissance. Observations and conclusions from these actions are described in the following sections. 5.1. Source Investigation Corning conducted stormwater management inspections to identify and evaluate possible causes of each COD benchmark exceedance per Tier 1 and Tier 2 response requirements of the NCG03 Permit. Specific, feasible courses of action were selected to reduce concentrations of COD as described below. On 29 April 2022, Corning representative Dalton Kaylor completed a walkthrough of the exterior building to determine possible sources contributing to the April 2022 COD exceedance. Observations included bird waste on stackable totes located outside of storm drain inlet #4 and a small amount of liquid under one of the portable restrooms located in the basin draining to storm drain inlet#8. Feasible actions noted during the inspection included operating the outdoor sweeper as weather and personnel allowed, moving stackable totes offsite no later than 6 May 2022, and a meeting scheduled for 3 May 2022 to discuss the relocation of the portable restrooms.The portable restrooms were later relocated. On 6 June 2022, Corning representative Steve Street completed a walkthrough of the exterior building to determine possible sources contributing to the May 2022 COD exceedance. Observations included rusty guardrails at Chiller 11, steel banding debris along the east curb, sixty (60) steel reels (24-inch with phosphate-coated wire) located at storm drain inlet #8, and stained concrete where the two portable restrooms were previously located outside the warehouse office. Feasible actions noted during the inspection included operating the outdoor sweeper as weather and personnel allowed, submitting maintenance workorders for replacing guardrail and cleaning concrete, and working with the warehouse supervisor to return phosphate-coated wire to the vendor for reuse. On 14 November 2022, Corning representative Steve Street completed a walkthrough of the exterior building to determine possible sources contributing to the October 2022 COD exceedance. Observations included two hundred and fourteen(214) steel reels (24-inch with phosphate-coated wire) located at the northeast corner of the HAT Lab. The wire was believed to be coated with a thin layer of oil to prevent rust from occurring. The warehouse manager, warehouse supervisor, EHS manager, and plant manager were notified that the reels were stored in a manner that exposes them to stormwater,and the warehouse manager took action to address the issue and have the reels returned to the vendor. GN11195/CAR250078 Corning Hickory COD Action Plan 9 April 2025 Geosynte& consultants Geosyn[ec Consultants of NC,P.C. On 21 March 2025,Corning representative Lorissa Milton completed a walkthrough of the exterior building to determine possible sources contributing to the March 2025 COD exceedance. Observations included de-icing material containing potassium chloride used in February 2025 due to inclement weather(which may have entered ice melt), limited outdoor metal reel storage,pollen accumulation at the outfall discharge pipe, and lack of filtration at one storm drain in Drainage Area 3. Feasible actions identified during the inspection included operating the outdoor sweeper after inclement weather, implementing signage and guidance to limit storage of metal reels in Drainage Area 3, and incorporating additional filtration in Drainage Area 3. GN11195/CAR250078 Coming Hickory COD Action Plan 10 April 2025 Geosynte& consultants GeoWn[ec Consultants of NC,P.C. 6. REMEDY ACTIONS Since entering tiered monitoring status in April 2022,the Site has taken several actions to mitigate the COD levels at the Site, including removal of portable restrooms, increased sweeping in industrial stormwater drainage areas, and removal of outdoor steel reels from the Site. This section describes the actions that have been taken thus far as well as additional actions that may be taken in the future. 6.1. Completed Actions In an effort to reduce COD concentrations in stormwater, Corning has taken multiple steps to remove possible sources of COD in Drainage Area 3, including: • Increased operation of the outdoor sweeper per weather and staffing availability since May 2022; • Removal of stackable totes with visible bird waste in May 2022; • Removal of portable restrooms in May 2022; • Returned steel reels coated with residual oil to the vendor in October 2022; • Began a policy in which the sweeper is used in the drainage area immediately after a storm or inclement weather event in April 2025; and o As discussed in Section 5.1, inclement weather in February 2025 resulted in the use of de-icing materials on paved areas. These materials contained potassium chloride, which may have entered stormwater runoff and contributed to the elevated COD concentrations in March 2025 (EPA, 1993). Increased street sweeping after inclement weather events was implemented. • Revised the internal preventative maintenance tracking system for stormwater-related tasks to include additional guidance regarding inclement weather sampling in April 2025 (i.e., sampling to be conducted after street sweeping is completed). 6.2. Potential Future Remedy Actions As discussed in Section 6.1, reduced concentrations of COD were observed at the Site since the removal of totes, portable restrooms, and steel reels coated with residual oil was completed in 2022. After these actions were completed in October 2022, elevated concentrations of COD were not observed for over 2 years. Additional actions implemented in April 2025 include increased street sweeping after inclement weather and updates to internal preventative maintenance procedures. GN11195/CAR250078 Coming Hickory COD Action Plan 11 April 2025 Geosynte& consultants GeoWn[ec Consultants of NC,P.C. Additional actions recommended to be completed on an ongoing basis include removal of woody debris in Drainage Area 3 and relocation of steel reels where practicable. If reduced COD concentrations are not achieved after street sweeping and removal of woody debris from Drainage Area 3,potential future remedy actions include a feasibility evaluation of stormwater filters along the perimeter of exposed reel storage areas, implementation of signage and guidance to prevent warehouse employees from storing the metal reels in close proximity to SDO 3, and evaluation of a management process for cleaning the outfalls. If the above solutions do not resolve the COD exceedance issue, Corning may evaluate the unlabeled storm drain west of SDO 3 (outside the facility fence) that currently does not have a filter for filtration options such as a filter sock to absorb oil and remove sediment. GN11195/CAR250078 Coming Hickory COD Action Plan 12 April 2025 Geosynte& consultants GeoWn[ec Consultants of NC,P.C. 7. MONITORING PLAN 7.1. Monitoring Schedule SDO 3 is currently in Tier Three status. Tier Three status requires monthly sampling until three consecutive samples are below the benchmark values for all parameters. The Monitoring Plan proposed for the Site is consistent with the monitoring requirements outlined in Tier Three status. Continued monthly monitoring at SDO 3 is planned to assess the effectiveness of the remedy actions detailed in Section 6. If after six months of ongoing implementation of the remedy actions (i.e., September 2025), COD concentrations continue to exceed the benchmark or three consecutive samples below the COD benchmark have not been observed, Corning will contact the Division to discuss other options for returning to quarterly monitoring. Sample procedures for monthly monitoring are detailed in Section 7.2. 7.2. Sample Procedures 7.2.1. Identifying a Qualifying Storm Event SDO monitoring efforts will proceed during the first measurable storm event in the monthly monitoring period that meets all the following conditions: a. Occurs at least 72 hours after the previous measurable storm event b. Occurs during the Site's normal operating hours c. Does not coincide with adverse weather conditions d. Is characteristic of the volume and nature of the permitted discharge 7.2.2. Sample Collection and Handling Grab samples will be collected within the first 30 minutes of discharge from an SDO and continue until all SDOs that are discharging have been sampled. SDOs that are not sampled during the first measurable storm event in the monitoring period will be sampled during the next measurable storm event in the monitoring period until a sample has been collected. If, during the entire monitoring period, there is no discharge from an SDO during any measurable storm event, then Corning will report"No Discharge"in the monthly DMR. Samples will be collected at SDO 3. Sample collection and handling will be performed in accordance with procedures described in the NCG03 Permit. Samples will be collected within the first 30 minutes of a qualifying storm event using laboratory-provided bottles from flowing water without disturbing any sediments or other materials not associated with the flowing water. Sample GN11195/CAR250078 Coming Hickory COD Action Plan 13 April 2025 Geosynte& consultants GeoWn[ec Consultants of NC,P.C. bottles for pH, total suspended solids (TSS), total metals, COD, and oil and grease will be filled directly. All sample bottles will be clearly labeled with the name of the person collecting the sample, sampling location, date, and time of collection, analysis method, and any preservatives. Clean gloves (Nitrile or similar)will be used to handle sample bottles and to collect samples; gloves will be replaced between sampling locations. All samples will be immediately placed on ice and sent to the analytical laboratory within the required holding time (seven days for TSS). A chain of custody will be completed and included with each sample batch. 7.2.3. Laboratory Analyses SDO 3 will be sampled for pH, TSS, total metals, COD, and oil and grease as required by the NCG03 permit. The sample analysis Plan is summarized in the following table: Table 1 —Sample Analysis Plan Analyte Laboratory Method Sample Bottles (mL) Location pH Standard Method 4500 Plastic,unpreserved SDO 3 TSS Standard Method 2540D 1000 mL Plastic,unpreserved SDO 3 COD EPA Method 410.4 250 mL Plastic, preserved SDO 3 Total Metals EPA Method 6020 250 mL Plastic, preserved SDO 3 (Copper and Zinc) Oil and Grease EPA Method 1664B Three (3) 1000 mL glasses SDO 3 * EPA indicates Environmental Protection Agency A laboratory accredited by the State of North Carolina will be used for all analyses. The analytical laboratory will provide sample bottles including any required preservatives for sample collection. Laboratory results will be delivered in electronic format and will include all quality control data as required in the analytical methods. Laboratory quality control data will be reviewed, and any qualified/flagged data will be noted for reporting purposes. GN11195/CAR250078 Coming Hickory COD Action Plan 14 April 2025 Geosynte& consultants GeoWn[ec Consultants of NC,P.C. 8. CONCLUSIONS This Action Plan was prepared to document actions taken to reduce COD concentrations per the requirements in the NCG03 permit which took effect on 1 July 2021. Corning has demonstrated a commitment to resolving exceedances at the Site, as shown by implementation of several remedy actions. As outlined in this Action Plan, Corning has completed the following steps to address exceedances at the Site: • Documented exceedances • Conducted additional site inspections • Evaluated standard operating and housekeeping procedures • Implemented remedy actions • Instituted a monitoring plan Based on site inspections, organic debris around outfalls and ice melt runoff have been identified as possible sources of COD in stormwater generated at the Site. Remedy actions implemented to address these sources and reduce COD levels in Site stormwater include continuation of good housekeeping practices, such as street sweeping, and revising the internal maintenance tracking system to include additional guidance regarding inclement weather sampling in April 2025. Additional actions recommended to be completed on an ongoing basis include removal of woody debris in Drainage Area 3 and relocation of steel reels where practicable. Proper sampling procedures at SDO 3 will continue to monitor the effectiveness of these Remedy Actions. Because of the recent implementation of these practices, monthly sampling shall continue to be conducted to quantify impacts of these remedies. If after six months of ongoing implementation of the remedy actions (i.e., September 2025), COD concentrations are continuing to exceed benchmarks, Corning will contact the Division to discuss other options for returning to quarterly monitoring. GN11195/CAR250078 Coming Hickory COD Action Plan 15 April 2025 Geosynte& consultants GeoWn[ec Consultants of NC,P.C. 9. REFERENCES Corning Hickory Manufacturing and Technology Center. Stormwater Pollution Prevention Plan, 23 October 2024. EPA. Method 410.4, Revision 2.0, The Determination of Chemical Oxygen Demand by Semi- Automated Colorimetry. August 1993. State of North Carolina Department of Environmental Quality, Division of Energy, Mineral, And Land Resources. General Permit No. NCG030000. 30 June 2021. GN11195/CAR250078 Coming Hickory COD Action Plan 16 April 2025 TABLES Table 1 Stormwater Discharge Outfall Analytical Results Corning Optical Communications-Hickory Manufacturing And Technology Center Hickory,North Carolina Chemical Oxygen Demand(mg/L) Date Applicable Benchmark=120 mg/L SDO 3 7/7/2021 34 8/12/2021 29 9/16/2021 23 10/4/2021 27 12/11/20214 10 12/11/20215 41 1/9/2022 44 2/3/2022 71 3/7/2022 38 4/5/2022 148 5/6/2022 132 6/3/2022 61 7/25/2022 72 8/21/2022 24 10/12/2022 142 1/13/2023 10 4/13/2023 36 8/28/2023 119 10/20/2023 10 2/27/2024 54 4/9/2024 63 8/7/2024 78 11/5/2024 10 3/5/2025 130 Notes: 1. SDO=Stormwater Discharge Outfall 2.Blue highlighted cells indicate exceedances of benchmark concentrations. 3.mg/L=milligrams per liter 4.Result from Water Tech Labs analysis. 5.Result from Statesville Labs analysis. GN11195 Page 1 of 1 Geosyntec Consultants of NC,P.C. FIGURES �_•� 0 25 50 100 - a oano e Miles Johnson City —— F inston$ em Gree v - .. Asheville ' arl cttc Greenville Site Location All en- C nl i rnk�i s [ai. .. rniiMeok iein ... Legend QApproximate Site Boundary Site Location Map Corning Optical Communications,LLC N 1164 23rd Street SE Notes: Hickory,North Carolina 1. Site boundary sourced from Catawba County online datasets. USG Maps:Copyright:©2013 National Geosyntec°Geographicgraphic Society,i-cubed Geosyntec Consultants of NC,P.G. Figure World Street Map:Esri,HERE,Garmin,NGA,USGS, NC license No.:C-3500 and C-295 NIPS consultants ESRI_Street_Map:State of North Carolina DOT,Esri, 0 750 1,500 3,000 1 HERE,Garmin,INCREMENT P,NGA,USGS Feet GN 11195 April 2025 \\Raleigh-01\PRJ\C\Corning\Hickory\7.0 GIS\7.4 APRX\Corning Hickory\Corning Hickory.aprx 2/27/2025 9:55 AM 4VT --MOM 47 1, RUN Wood &itSteel mated Term Machine Desi n Warehouse •�My� g �'+�Mlllrl! .,. Steel Reel r eGJ "' Staging ,, MilliKoala Insulation Metal Recycling of Hickory ,-� Liquid Nitrogen Reels r �r US Conec, LTD '� • Hazardous Materials •,r w Storage Shed - Martin Marietta G y Q •uar °'" '`j Production Building Silos-� •-�, ` • ��� Transformers - � ,��.r � � a� ;• N .,�. Dumpsters �� _ William C & Chiller Plant r+� �� • .' • + - Reynolds Co -_� •� Steel Reels in 144 L ' d r�"•' F tF' *• L ifour Un T ruck�• a o - &Trailer Repair . - , Main Employee Parking Lot 400, �r . I Ma'ar, Earthst ra.hi I er ommu nit y Legend Site Layout Map Streams Drainage Areas Corning Optical Communications,LLC N 1164 23rd Street SE Approximate Site Boundary Hickory, North Carolina Notes: 1. Site boundary, stream locations, and elevation contours sourced from Catawba County online datasets. GeOSynteCu' Geosyntec Consultants ofNC,P.C. Figure 2. Site feature locations are approximate. Locations were georeferenced from Drawing C01 of the Corning Storm Water Pollution consultants NC License No.:C-3500 and C-295 Prevention Plan, Synterra, 5-6-2013, or were observed during the 7 April 2025 site visit. 200 100 0 200 2 3.AST=Aboveground Storage Tank. Feet r GN11195 April 2025 \\Raleigh-01\PRJ\C\Corning\Hickory\7.0 GIS\7.4 APRX\Corning Hickory\Corning Hickory.aprx 4/14/2025 11:41 AM 04 L r ay AGO now �k q a y , jr Drainage ; , R it 1�IAN��r . .: Drainage Area 3 - . I`T '�` ►c y ,r #6 Metal Recycling 1�' / JI SDO 3 Drainage SDO 2 Area 5 Roof Drain #2 #1 (L Roiom) #5 u SDO 5 Drainage US Conec, LTD Ar #4 #3 ' Production Building e Martin M arietta �Draina g� Quarry Area 111,Aw illiam C -, Reynolds Co 4, CU L CU ~ � i �IR� Unifour Truck ° ���, •�,��� &TraileCU r Repair Legend Stormwater Features Map Storm Drains Drainage Areas Corning Optical Communications,LLC N 1164 23rd Street SE Streams Storm Drain Outfalls Hickory, North Carolina Notes: Geosyntec° Geosyntec Consultants ofNC,P.C. Figure 1. Site boundary, stream locations, and elevation contours sourced from Catawba County online datasets. consultants NC lAcense No.:C-3500 and C-295 2. Site feature locations are approximate. Locations were georeferenced from Drawing C01 of the Corning Storm Water Pollution 200 100 0 200 3 Prevention Plan, Synterra, 5-6-2013, or were observed during the 7 April 2025 site visit. ii@ Feet GN11195 April 2025 \\Raleigh-01\PRJ\C\Corning\Hickory\7.0 GIS\7.4 APRX\Corning Hickory\Corning Hickory.aprx 4/9/2025 3:31 PM 160 • 140 • 120 100 J OA 80 • O • • 60 • • • • 40 • • 20 • • • • 0 6/1/2021 12/18/2021 7/6/2022 1/22/2023 8/10/2023 2/26/2024 9/13/2024 4/1/2025 • COD COD Benchmark Notes: COD Concentrations at SDO 3 1.The benchmark for Chemical Oxygen Demand(COD)is 120 mg/L,per the 2021 State of North Carolina General Permit No. Corning Optical Communications, LLC NCG030000 for Metal Fabrication. 1164 23rd Street Southeast 2.mg/L=milligrams per liter Hickory, North Carolina 3.SDO=Storm Drain Outfall Geosyntec'% Geosyntec Consultants of NC,P.C. Figure consultants NC License No.:C 3500 and C 295 4 Raleigh,NC April 2025 APPENDIX A NCG030000 GENERAL PERMIT STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF ENERGY,MINERAL,AND LAND RESOURCES GENERAL PERMIT NO. NCG030000 TO DISCHARGE STORMWATER UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM For establishments primarily engaged in the following activities: Metal Fabrication In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission and the Federal Water Pollution Control Act,as amended,this permit is hereby issued to all owners or operators,hereafter permittees,which are covered by this permit as evidenced by receipt of a Certificate of Coverage (COC) by the Environmental Management Commission to allow the discharge of stormwater to the surface waters of North Carolina or to a separate storm sewer system conveying discharges to surface waters in accordance with the terms and conditions set forth herein. Coverage under this General Permit is applicable to: ♦ All owners or operators of stormwater point source discharges associated with activities from establishments primarily engaged in: • Heat Treating of Metal [standard industrial classification (SIC) 3398] • Rolling,Drawing,and Extruding of Nonferrous Metals (SIC 335) • Fabricating of Metal Products (SIC 34) • Manufacturing of Industrial and Commercial Machinery(SIC 35) • Manufacturing of Electronic Equipment(SIC 36) • Manufacturing of Transportation Equipment(SIC 37) • Manufacturing of Measuring and Analyzing Instruments (SIC 38). ♦ Stormwater point source discharges from like industrial activities deemed by The Division of Energy, Mineral,and Land Resources (the Division)to be similar to these operations in the process, or the discharges,or the exposure of raw materials,intermediate products,by-products,final products,or waste products. Except upon Division determination of similarity as provided immediately above, coverage under this General Permit is not applicable to: ♦ Establishments primarily engaged in ship and boat building and repairing(SIC 373),which are covered under general stormwater permit NCG190000. The General Permit shall become effective on July 1, 2021. The General Permit shall expire at midnight on June 30, 2026. Signed this 30th day of June 2021. Original signed by Brian Wrenn Brian Wrenn, Director Division of Energy,Mineral,and Land Resources By the Authority of the Environmental Management Commission Permit No.NCG030000 TABLE OF CONTENTS PART A NCG030000 PERMIT COVERAGE PART B STORMWATER POLLUTION PREVENTION PLAN (SWPPP) B-1. Responsible Party B-2. General Location Map B-3. Site Map B-4. Narrative Description of Industrial Process B-5. Feasibility Study B-6. Evaluation of Stormwater Outfalls B-7. Stormwater Best Management Practice (BMP) Summary B-8. Secondary Containment Plan B-9. Spill Prevention and Response Procedures B-10. Solvent Management Plan B-11. Preventative Maintenance and Good Housekeeping B-12. Employee Training B-13. Representative Outfall Status B-14. Annual SWPPP Review and Update B-15. Annual On-line SWPPP Certification (Forthcoming) B-16. Notice to Modify the SWPPP B-17. SWPPP Documentation PART C OPERATIONAL REQUIREMENTS C-1. Operation and Maintenance of Treatment and Control Systems C-2. Stormwater Control Measure (SCM) Clean-Out C-3. Residuals Management C-4. Corrective Actions C-5. Draw Down of Treatment Facilities for Essential Maintenance C-6. Bypasses of Stormwater Treatment Facilities C-7. Upsets C-8. Required Notices for Bypasses and Upsets PART D QUALITATIVE MONITORING OF STORMWATER DISCHARGES D-1. Visual Inspections D-2. Qualitative Monitoring Response i Permit No.NCG030000 PART E ANALYTICAL MONITORING OF STORMWATER DISCHARGES E-1. Required Baseline Monitoring E-2. Baseline Sampling Benchmarks E-3. Methodology for Collecting Samples E-4. Locations for Collecting Samples E-5. Tier I Response: Single Benchmark Exceedance E-6. Tier II Response: Two Consecutive Benchmark Exceedances E-7. Tier III Response: Four Benchmark Exceedances Within the Permit Term PART F SUBMITTAL OF DISCHARGE MONITORING REPORTS (DMRs) F-1. Deadlines for Submittal F-2. Submittal Process before Electronic Discharge Monitoring Reporting(eDMR) F-3. Submittal Process after Electronic Discharge Monitoring Reporting (eDMR) F-4. Results Below Detection Limits F-5 Occurrences of No Discharge F-6. Reports if More Frequent Monitoring Has Occurred F-7. Report if Begin Discharging to a Waterbody Not Listed on the COC F-8. Qualitative Monitoring Reports F-9. Monitoring Report Retention PART G OTHER OCCURANCES THAT MUST BE REPORTED PART H PERMIT ADMINISTRATION H-1. Signatory Requirements H-2. General Permit Expiration H-3. Planned Changes H-4. Transfers H-5. When an Individual Permit May be Required H-6. When an Individual Permit May be Requested H-7. General Permit Modification,Revocation and Reissuance, or Termination H-8. Certificate of Coverage Actions H-9. Requirement to Report Incorrect Information H-10. Waivers from Electronic Reporting H-11. Annual Administering and Compliance Monitoring Fee Requirements H-12. Flow Measurements H-13. Test Procedures H-14. Availability of Reports ii Permit No.NCG030000 PART I COMPLIANCE AND LIABILITY I-1. Compliance Schedule I-2. Duty to Comply I-3. Duty to Mitigate I-4. Civil and Criminal Liability I-5. Oil and Hazardous Substance Liability I-6. Property Rights I-7. Severability I-8. Duty to Provide Information I-9. Penalties for Tampering I-10. Penalties for Falsification of Reports I-11. Onshore or Offshore Construction I-12. Duty to Reapply I-13. Inspection and Entry I-14. Need to Halt or Reduce not a Defense PART J DEFINITIONS iii Permit No.NCG030000 PART A: NCG030000 PERMIT COVERAGE All persons desiring to have facilities covered by this General Permit must register with the Division of Energy,Mineral,and Land Resources (the Division) by filing a Notice of Intent(NOI) and paying the applicable fees.The NOI shall be submitted and a Certificate of Coverage (COC) issued prior to any discharge of stormwater associated with industrial activity that has a point source discharge to surface waters of the state or to a separate storm sewer system conveying discharges to surface waters. Any owner or operator not wishing to be covered or limited by this General Permit may make application for an individual National Pollutant Discharge Elimination System (NPDES) permit in accordance with NPDES procedures in 15A NCAC 2H .0100,stating the reasons supporting the request.Any application for an individual permit shall be made at least 180 days prior to commencement of discharge. This General Permit does not cover activities or discharges covered by an individual NPDES permit until the individual permit has been rescinded or revoked.Any person conducting an activity covered by an individual permit,but which could be covered by this General Permit may request that the individual permit be revoked and coverage under this General Permit be provided. If industrial materials and activities are not exposed to precipitation or runoff as described in 40 CFR§122.26(g),the facility may qualify for a No Exposure Exclusion from NPDES stormwater discharge permit requirements.Any owner or operator wishing to obtain a No Exposure Exclusion from permitting must submit a No Exposure Certification NOI form to the Division; must receive approval from the Division; must maintain no exposure conditions unless authorized to discharge under a valid NPDES stormwater permit; and must recertify the No Exposure Exclusion annually. Any facility may apply for new or continued coverage under this permit until a Total Maximum Daily Load (TMDL) for pollutants for stormwater discharges is established.A TMDL is for one or more watersheds with one or more impaired waters. The TMDL sets one or more pollutant-loading limits that affects one or more watersheds,or portion of a watershed,draining to one or more impaired waters. A list of approved TMDLs for the state of North Carolina can be found at https://deq.nc.govlabout/divisions/water-resources/planning/modeling-assessmentitmdls.To not be subject to the TMDL,each facility with one or more discharges to watersheds affected by a TMDL must demonstrate it does not have reasonable potential to violate applicable water quality standards for those pollutants identified in the TMDL as a result of discharges. If the Division determines that discharges have reasonable potential to cause water quality standard violations, the facility shall apply for an individual permit 180 days prior to the expiration date of this General Permit.After that individual permit becomes effective,the facility will no longer have coverage under this General Permit.Although there is not a TMDL for every impaired water,the permittee must identify impaired waters in the General Location Map,as outlined in the Stormwater Pollution Prevention Plan (SWPPP),in Part B of this permit. The Department of Environmental Quality- Division of Water Resources integrated reports (https://deq.nc.gov/about/divisions/water- resources/planning/modeling-assessment/water-quality-data-assessment/integrated-report-files) include assessments of waters monitored in North Carolina. Use the most recent final report to identify impaired waters. Until this permit expires or is modified,revoked,or rescinded,the permittee is authorized to discharge stormwater to the surface waters of North Carolina or a separate storm sewer system which has been treated and managed in accordance with the terms and conditions of this General Permit and the requirements of the permittee's COC. Page 1 of 31 Permit No.NCG030000 The permittee's COC is hereby incorporated by reference into this General Permit.Any violation of the COC is a violation of this General Permit and subject to enforcement action as provided in the General Permit. Any other point source discharge to surface waters of the state is prohibited unless it is an allowable non-stormwater discharge or is covered by another permit,authorization,or approval. The discharges allowed by this General Permit shall not cause or contribute to violations of Water Quality Standards.Discharges allowed by this permit must meet applicable wetland standards as outlined in 15A NCAC 213.0230 and.0231 and water quality certification requirements as outlined in 15A NCAC 2H .0500. If activities covered by this permit expand or change after issuance of the COC such that the types of discharges are affected,the permittee must first contact the Division to determine if modifications to the COC are necessary. This permit does not relieve the permittee's responsibility for compliance with any other applicable federal,state, or local law,rule,standard,ordinance,order,or decree. Page 2 of 31 Permit No.NCG030000 PART B: STORMWATER POLLUTION PREVENTION PLAN (SWPPP) The permittee shall develop a Stormwater Pollution Prevention Plan (SWPPP).The SWPPP shall be maintained on site unless exempted from this requirement by the Division.The permittee shall implement the SWPPP and all Best Management Practices (BMPs�consistent with the provisions of this permit,to control contaminants entering surface waters. These items shall exist for the duration of the permit term and made available to the Director upon request and also shall be sent to the Regional Office upon request.The SWPPP shall be considered public information in accordance with II-88 of this General Permit. The SWPPP shall include,at a minimum,the following items: B-1. Responsible Party The SWPPP shall identify specific positions responsible for the overall coordination,development, implementation,and revision of the SWPPP. Responsibilities for all components of the SWPPP shall be documented and position assignments provided. B-Z. General Location Map The General Location Map shall be a USGS quadrangle map or appropriately drafted equivalent map that includes: (a) The facility's location in relation to transportation routes and surface waters; (b) The name of the receiving waters to which the stormwater outfalls discharge,or if the discharge is to a municipal separate storm sewer system,the name of the municipality and the ultimate receiving waters; (c) Any impaired receiving waters,use the most recent final integrated report (httl2s://deq.nc.gov/about/divisions/water-resources/12lanning/modeling= assessment/water-quality-data-assessment/integrated-report-files)to identify impaired waters; (d) If the site is in a watershed for which a TMDL has been established,include a list of the parameters of concern (those exceeding water quality standards). B-3. Site Map The Site Map shall include the following at a scale sufficient to clearly depict all required features. At a minimum,the map shall include: (a) Site property/permit boundary; (b) Site topography; (c) Buildings,roads,parking areas and other built-upon areas; (d) Industrial activity areas (including,but not limited to: vehicle maintenance activities, metal fabrication of materials or equipment,storage of materials,disposal areas,process areas,loading and unloading areas,and haul roads); (e) Stormwater discharge outfalls and a table of latitudes and longitudes; (f) Delineated drainage area for each outfall and a table of impervious percentage for each drainage area; (g) Stormwater Control Measures (SCMs); (h) All stormwater collection/drainage features,structures and direction of flow; Page 3 of 31 Permit No.NCG030000 (i) On-site and adjacent surface waters and wetlands; and (j) A graphic scale and north arrow. B-4. Narrative Description of Industrial Processes The narrative description shall include: (a) Storage practices; (b) Loading and unloading activities; (c) Outdoor process areas; (d) Dust or particulate generating and control processes; (e) Waste disposal practices; and (f) A list of the potential pollutants that could be expected to be present in the stormwater discharge from each outfall. B-5. Feasibility Study A review of the technical and economic feasibility of changing the methods of operations and/or storage practices to eliminate or reduce exposure of materials and processes to rainfall and runoff flows. Wherever practical,the permittee shall prevent exposure of all storage areas,material handling operations,and manufacturing or fueling operations. In areas where elimination of exposure is not practical,the review shall document the feasibility of diverting the stormwater runoff away from areas of potential contamination. B-6. Evaluation of Stormwater Outfalls On an annual basis,the permittee shall evaluate all stormwater outfalls for the presence of non- stormwater discharges. (a) If no non-stormwater discharges are present,the permittee shall certify the evaluation results.This certification shall be dated and signed in accordance with the requirements found in H-1 and retained with the SWPPP. (b) If non-stormwater discharges are present,the permittee shall identify the source and record whether the discharge is otherwise permitted by rule or a different permit.The permittee shall evaluate the environmental significance of the non-stormwater discharges. A summary written record shall be dated and signed in accordance with the requirements found in H-1 and retained with the SWPPP. B-7. Stormwater BMP Summary The installation and implementation of BMPs shall be based on the assessment of the potential for sources to contribute significant quantities of pollutants to stormwater discharges and on data collected through monitoring of stormwater discharges.The BMP Summary shall be reviewed and updated annually. The BMP Summary shall include: (a) Written record of the specific rational for installation and implementation of the selected site BMPs. (b) Structural and nonstructural practices to minimize the exposure and transport of materials in stormwater. (c) BMPs for vehicle maintenance activities. Page 4 of 31 Permit No.NCG030000 B-8. Secondary Containment Plan In order to prevent leaks and spills from contaminating stormwater runoff,secondary containment is required for: bulk storage of liquid materials including petroleum products; storage in any amount of water priority chemicals listed in Section 313 of Title III of the Superfund Amendments and Reauthorization Act (SARA); and storage of hazardous substances in any amount. For facilities subject to the federal Spill Prevention,Control,and Countermeasure (SPCC) regulation,the SPCC Plan may be used to support compliance with this requirement. The Secondary Containment Plan shall include: (a) A table or summary of tanks and stored materials equipped with secondary containment systems; (b) Manually activated valves or other similar devices that are securely closed with a locking mechanism if the secondary containment devices are connected to the stormwater conveyance system; (c) A commitment to visually observe any accumulated stormwater prior to release for color, foam, outfall staining,visible sheens,and dry weather flow; (d) A commitment to only release accumulated stormwater that is uncontaminated by any material; and (e) Records on every release from a secondary containment system that include: the individual making the observation,a description of the accumulated stormwater,and the date and time of the release. These records shall be kept for a period of five (5) years. B-9. Spill Prevention and Response Procedures A responsible person shall be on-site at all times during facility operations that have potential to contaminate stormwater runoff through spills or exposure of materials associated with the facility operations. For facilities subject to the federal SPCC regulation,the SPCC Plan may be used to support compliance with this requirement. The Spill Prevention and Response Procedures (SPRP) shall include: (a) An assessment of areas of the facility where there is the potential for spills; (b) A list of trained facility personnel responsible for implementing the SPRP; (c) A signed and dated acknowledgement in which staff members accept responsibilities for the SPRP; (d) An inventory of spill response materials and equipment and the locations for storing these items; (e) Written procedures for proper cleanup and disposal of spilled materials; and (f) A list of significant spills or leaks of pollutants that have occurred during the previous three (3) years and any corrective actions taken to mitigate spill impacts or the notation that no spills have occurred. This list shall be updated on annual basis. B-10. Solvent Management Plan The Solvent Management Plan shall be incorporated as a separate chapter into the Stormwater Pollution Prevention Plan (SWPPP). The Solvent Management Plan (SMP) shall include: Page 5 of 31 Permit No.NCG030000 (a) an annually updated and quantified inventory of solvents present on site during the previous three years; (b) a narrative description of the facility locations and uses of solvents; (c) the method of disposal,including quantities disposed on-site and off-site; and (d) the management procedures and engineering measures for assuring that solvents do not spill or leak into stormwater. If solvents are not stored or used onsite,the owner must certify that in the SWPPP.The Division may at is discretion require submittal,review,and approval of the SMP. B-11. Preventative Maintenance and Good Housekeeping Program A preventative maintenance and good housekeeping program (PMGHP) shall be developed and implemented. The PMGHP shall include: (a) A schedule of inspections,maintenance,and housekeeping measures for industrial activity areas including,at a minimum,all material storage and handling areas, disposal areas, process areas,loading and unloading areas,haul roads,and vehicle maintenance areas. Inspections shall occur at a minimum on a quarterly schedule (January-March,April-June, July-September, October-December). (b) A plan for disposing spent lubricants and fuels properly and in accordance with applicable federal disposal regulations. (c) A record of inspections,maintenance,and housekeeping activities. B-12. Employee Training Employee training shall be developed and provided on an annual basis for facility personnel responsible for operations that have the potential to contaminate stormwater runoff. The training shall be documented by the date,signature,and printed or typed name of each employee trained. Signatures may be original or electronic. The annual employee training shall include, at a minimum,the following topics: (a) General stormwater awareness; (b) The provisions of the current NCG030000 general permit. (c) Spill response training; (d) Used oil management; (e) Spent solvent management; (f) Secondary containment releases; (g) Fueling procedures; (h) Disposal of spent abrasives; (i) Sanding,painting,and blasting procedures,and (j) Used battery management. Page 6 of 31 Permit No.NCG030000 B-13. Representative Outfall Status If a facility has multiple discharge locations with substantially identical stormwater discharges that are required to be sampled,the permittee may petition the Director for representative outfall status (ROS). If it is established that the stormwater discharges are substantially identical and the permittee is granted representative outfall status,then analytical sampling requirements may be performed at a reduced number of outfalls. If the Division has granted ROS,documentation from the Division shall be part of the SWPPP. The permittee shall notify the Division of any site or activity modifications that result in a change to ROS. The permittee must request reissuance of ROS by submitting a written request to the Division's Central Office within thirty(30) days prior to the expiration of this General Permit to maintain ROS. B-14. Annual SWPPP Review and Update All aspects of the SWPPP shall be reviewed and updated on an annual basis.The permittee shall amend the SWPPP whenever there is a change in design,construction,operation,site drainage, maintenance,or configuration of the physical features which may have a significant effect on the potential for the discharge of pollutants to surface waters. In addition,the SWPPP update shall include a review and comparison of sample analytical data to benchmark values (if applicable) over the past year, including a discussion about Tiered Response status.The permittee shall use the Division's Annual Summary Data Monitoring Report(DMR) form, available from the Stormwater Permitting Program's website (httl2s://deq.nc.gov/about/divisions/energy-mineral-land-resources/npdes-stormwater-gps). B-15. Annual On-Line SWPPP Certification (Forthcoming) After the Division's ePermitting system develops the capability to receive this information, the permittee shall submit an on-line certification that the annual SWPPP review and update has been completed in a manner that meets the conditions of this permit. B-16. Notice to Modify the SWPPP The Director may notify the permittee when the SWPPP does not meet one or more of the minimum requirements of the permit.Within 30 days of such notice,the permittee shall submit a time schedule to the Director for modifying the SWPPP to meet minimum requirements. Upon completion of the modifications,the permittee shall provide certification in writing in accordance with H1 and HH7 of this permit to the Director that the changes have been made. B-17. SWPPP Documentation Copies of the SWPPP shall be maintained on-site and be available electronically to the Division upon request.These records or copies shall be maintained for a period of at least five years.This period may be extended by request of the Director at any time [40 CFR 122.41]. Page 7 of 31 Permit No.NCG030000 PART C: OPERATIONAL REQUIREMENTS Permitted operations shall be subject to the following operational requirements. C-1. Operation and Maintenance of Treatment and Control Systems The permittee shall at all times: (a) Properly operate and maintain all facilities and systems of treatment and control and related appurtenances which are installed or used by the permittee to achieve compliance with the conditions of this permit. (b) Implement laboratory controls and quality assurance procedures for onsite laboratories and/or on-site testing. (c) Operate back-up or auxiliary facilities or similar systems which are installed by a permittee only when the operation is necessary to achieve compliance with the conditions of this permit [40 CFR 122.41(e)]. C-2. SCM Clean-Out SCMs must be cleaned out when sediment storage capacity equals or exceeds SO percent of the design sediment volume or if visible sedimentation is leaving the property. C-3. Residuals Management The residuals generated from treatment facilities must be disposed of in accordance with applicable standards and in a manner such as to prevent any pollutants from such materials from entering waters of the state or navigable waters of the United States. C-4. Corrective Actions The permittee shall take corrective actions if: self-inspections required by this permit identify a need for corrective actions,a facility fails to perform satisfactorily, or a facility creates nuisance conditions. Corrective actions shall include,but not be limited to: maintenance,modifications, or additions to existing control measures,the construction of additional or replacement treatment or disposal facilities,or implementation of new BMPs. Corrective actions shall be completed as soon as possible considering adverse weather and site conditions C-S. Draw Down of Treatment Facilities for Essential Maintenance The permittee may draw down stormwater treatment facilities if these conditions are met: (a) Treatment facilities shall be drawn down in manner to ensure benchmarks and/or limits are met; (b) Analytical sampling data of the water stored in the treatment facility demonstrates that the discharge will not exceed benchmarks in this permit. The sampling data shall be collected no more than 14 calendar days prior to the draw down; and (c) The drawdown is for essential maintenance to assure efficient operation. C-6. Bypasses of Stormwater Treatment Facilities Bypass is prohibited,and the Division may take enforcement action against a permittee for bypass unless the permittee provides engineering evidence that all three of the following conditions are met: Page 8 of 31 Permit No.NCG030000 (a) The bypass was unavoidable to prevent loss of life,personal injury or severe property damage; (b) There were no feasible alternatives to the bypass,such as the use of auxiliary control facilities,retention of stormwater,or maintenance during normal periods of equipment downtime or dry weather.This condition is not satisfied if adequate backup controls should have been installed in the exercise of reasonable engineering judgment to prevent a bypass which occurred during normal periods of equipment downtime or preventive maintenance; and (c) The permittee submitted notices and identified the reason(s) for the bypass as required under C-8 below. C-7. Upsets Diversions of stormwater from treatment facilities may be considered as an upset,rather than a bypass,if the permittee can demonstrate to the Director that all of the following conditions have been met. In any enforcement proceeding,the permittee seeking to establish the occurrence of an upset has the burden of proof. (a) The permittee demonstrates that the upset was not caused by operational error,improperly designed treatment or control facilities,lack of preventive maintenance,or careless or improper operation. (b) The permittee agrees to take remedial measures if necessary. (c) The permittee submitted notice of the upset and identified the cause(s) of the upset as required under Item C-8 below. C-8. Required Notice for Bypass or Upset After a permittee becomes aware of an occurrence that must be reported,the permittee shall contact the appropriate Division regional office within the timeframes and in accordance with the requirements listed in Table 1 below. Occurrences outside normal business hours may also be reported to the Department's Environmental Emergency Hotline at(800) 858-0368. Table 1: Bypass and Upset Reporting Requirements Event [40 CFR 122.41(m)(3)] Reporting Requirements Anticipated Bypass Written report at least ten days prior to the anticipated bypass. The written report shall include an evaluation of the anticipated quantity, quality,and effect of the bypass. Unanticipated Bypass or Oral or electronic notification within 24 hours of the event, Upset and Written report within 7 calendar days of the event. The written report shall include an evaluation of the quantity, quality,and effect of the bypass. Page 9 of 31 Permit No.NCG030000 PART D: QUALITATIVE MONITORING OF STORMWATER DISCHARGES The purpose of qualitative monitoring is to implement a quick and inexpensive way to evaluate the effectiveness of the permittee's SWPPP,to identify the potential for new sources of stormwater pollution,and to prompt the permittee's response to pollution. D-1. Visual Inspections (a) Visual inspections shall be made at each stormwater discharge outfall (SDO) that discharges stormwater associated with industrial activity unless representative outfall status specifically for visual monitoring has been approved in writing by the Division. (b) Visual inspections shall be performed concurrent with required analytical monitoring. (c) Visual inspections are not required to be performed outside of the facility's normal operating hours. (d) Visual inspections shall be recorded on the Division's Stormwater Discharge Outfall Qualitative Monitoring Report (QMR) form and shall include observations of: i. Color ii. Odor iii. Clarity iv. Floating Solids V. Suspended Solids vi. Foam vii. Oil Sheen viii. Deposition at or immediately below the outfall ix. Erosion at or immediately below the outfall,and X. Other obvious indicators of stormwater pollution. (e) Inability to perform inspections because of adverse weather or lack of discharge during the monitoring period shall not constitute a failure to monitor if the event is documented in the SWPPP and recorded on the Qualitative Monitoring Report. D-2. Qualitative Monitoring Response (a) If the permittee's qualitative monitoring indicates that the SWPPP and/or existing stormwater BMPs are ineffective,or that significant stormwater contamination is present, then the permittee shall investigate potential causes,evaluate the feasibility of corrective actions,and implement those feasible corrective actions within sixty(60) days. (b) A written record of the permittee's investigation, evaluation,and response actions shall be kept in the SWPPP. Page 10 of 31 Permit No.NCG030000 PART E: ANALYTICAL MONITORING OF STORMWATER DISCHARGES This part applies to industrial stormwater discharges from covered activities. E-1. Required Baseline Sampling The permittee shall perform baseline sampling of all stormwater discharge outfalls and/or authorized representative discharge outfalls in accordance with this part. (a) Grab samples shall be collected,analyzed, and reported for the parameters listed in Table 2. (b) Grab samples shall be analyzed for pH within 15 minutes of collection. (c) The total rainfall amount for each sampling event shall be recorded in inches. Total rainfall shall be determined from an on-site rain gauge or a regional rain gauge located within one (1) mile of the facility. (d) Samples shall be collected from four separate monitoring periods per year unless the facility is in Tier Two or Tier Three status. A minimum of thirty(30) days must separate any two sampling events during the following periods: i. January 1 - March 31 ii. April 1 -June 30 iii. July 1 -September 30. iv. October 1 - December 31 (e) If the facility was in Tier Two or Tier Three status under the previous permit,the facility shall continue monthly monitoring and reporting requirements until relieved by the provisions of this permit or the Division. E-2. Baseline Sampling Benchmarks (a) Analytic results for each parameter shall be compared to the benchmark values for the appropriate receiving stream classification as provided in Table 2. An exceedance of a benchmark value is not a permit violation; however, failure to respond in accordance with E-2(b) below is a permit violation. (b) An exceedance of any benchmark value shall require a tiered response for that outfall. A single exceedance of a benchmark value shall require a Tier One response for that outfall. Two benchmark value exceedances in a row shall require a Tier Two response for that outfall. Four benchmark exceedances for a parameter within the permit term shall require a Tier Three response for that outfall. (c) Baseline sampling benchmarks shall be in accordance with Table 2 below. Table 2: Summary of Quarterly Baseline Sampling Requirements Parameter Parameter Receiving Stream Units Benchmark Code Classifications Total Suspended Solids All,except... mg/L 100 C0530 (TSS) HQW, ORW,Tr, PNA mg/L 50 Freshwater Standard 6-9 00400 pH1 Saltwater Standard 6.8-8.5 00340 (COD)Chemical Oxygen Demand All mg/L 120 Page 11 of 31 Permit No.NCG030000 Copper,Total Recoverable Freshwater mg/L 0.010 01119 as Cu)( Saltwater mg/L 0.0058 Lead,Total Recoverable Freshwater mg/L 0.075 01051 as Pb)( Saltwater mg/L 0.220 Zinc,Total Recoverable Freshwater mg/L 0.126 01094 as Zn ( ) Saltwater mg/L 0.095 Non-Polar Oil&Grease 00552 Per EPA Method 1664 All mg/L 15 SGT-HEM 46529 Total Rainfall of Sampled _ Inches - Event 1 Grab samples shall be analyzed for pH within 15 minutes of collection. E-3. Methodology for Collecting Samples (a) Outfall monitoring efforts shall begin with the first measurable storm event in the monitoring period that meets all the following conditions: i. Occurs at least 72 hours after the previous measurable storm event unless E-3 (b) applies, ii. Occurs during the facility's normal operating hours, iii. Does not coincide with adverse weather conditions,and iv. Is characteristic of the volume and nature of the permitted discharge. (b) The 72-hour storm interval may not apply if: i. The permittee is able to document that a shorter interval is representative for local storm events during the sampling period,and ii. The permittee obtains approval from the Division's Regional Office. iii. After authorization by the Division's Regional Office,a written approval letter must be kept on site in the permittee's SWPPP. (c) Grab samples shall be collected within the first 30 minutes of discharge from an outfall and continue until all outfalls that are discharging have been sampled. (d) Outfalls that are not sampled during the first measurable storm event in the monitoring period shall be sampled during the next measurable storm event in the monitoring period until a sample has been collected. (e) If,during the entire monitoring period,there is no discharge from an outfall during any measurable storm event then the permittee shall: i. Report"No Discharge"in the DMR, ii. Note"No Discharge"in the SWPPP, and iii. Submit the DMR within 30 days after the end of the monitoring period. (f) Lack of a discharge from an outfall for the monitoring period shall not constitute failure to monitor as long as the above permit conditions are met. Page 12 of 31 Permit No.NCG030000 (g) If the sampled storm event coincides with a known non-stormwater discharge that is deemed permitted under 15A NCAC 02 .0106,then this shall be noted on the DMR. E-4. Locations for Collecting Samples Samples shall be collected at all stormwater discharge outfalls (SDO) that discharge stormwater associated with industrial activity. If the Division has issued a representative outfall status approval letter,then the permittee shall collect samples from all SDOs in accordance with the ROS approval letter. (a) All samples shall be taken before the discharge joins or is diluted by any other waste stream,body of water,or substance. (b) Monitoring points as specified in this General Permit shall not be changed without written notification to and approval by the Division [40 CFR 122.41(j)]. E-5. Tier One Response: Single Benchmark Exceedance The facility will remain in Tier One status until three consecutive samples are under the benchmark or are inside the benchmark range for all parameters. (a) If any sampling result is above the benchmark value for any parameter at any outfall,then the permittee shall respond in accordance with Table 3 to identify and address the source of that exceedance for that parameter. (b) Each required response shall be documented in the SWPPP as each action occurs including; the date and value of the benchmark exceedance, the date the Division's Regional Office was notified of the exceedance,the inspection date,the personnel conducting the inspection,the selected feasible actions,and the date the selected feasible actions were completed. (c) Each exceedance of a benchmark parameter shall individually require a Tier One response. (d) The Tier One response shall be in accordance with Table 3 below. Table 3: Tier One Response for a Benchmark Exceedance Timeline From Receipt of Tier One Required Response/Action Sampling Results Continuously i. Document the exceedance and each required response/action in the SWPPP in accordance with E-5(b) above. Within two weeks ii. Notify the Division's Regional Office of the exceedance date and value via email or,when it is developed,an electronic form created by the Division for reporting exceedances. iii. Conduct a stormwater management inspection. iv. Identify and evaluate possible causes of the benchmark exceedance. Within one month v. Select specific,feasible courses of action to reduce concentrations of the parameter(s) of concern including,but not limited to, source controls,operational controls,or physical improvements. Within two months vi. Implement the selected feasible actions. Page 13 of 31 Permit No.NCG030000 E-6. Tier Two Response: Two Consecutive Benchmark Exceedances The facility will remain in Tier Two status until three consecutive samples are under the benchmark or are inside the benchmark range for all parameters. (a) If any two consecutive sampling results in a row for the same parameter are above the benchmark value at an outfall,then the permittee shall respond in accordance with Table 4 to identify and address the source of exceedances for that parameter. (b) After implementing the specific feasible courses of action,perform monthly monitoring at every outfall where a sampling result exceeded the benchmark value for two consecutive samples for all parameters until three samples in a row are below the benchmark value or are inside the benchmark range. (c) Each required response shall be documented in the SWPPP as each action occurs including; the dates and values of the benchmark exceedances,the date the Division's Regional Office was notified of the consecutive exceedances,the inspection date,the personnel conducting the inspection,the selected feasible actions,the date the selected feasible actions were completed,and the monthly monitoring results. (d) Each pair of two consecutive exceedances of a single benchmark parameter at a single outfall shall constitute an event that requires a Tier Two response. (e) The Tier Two response shall be in accordance with Table 4 below. (f) Alternatively,in lieu of the Tier Two response,the permittee may,after two consecutive exceedances, implement a Tier Three response. Table 4: Tier Two Response for Two Consecutive Benchmark Exceedances Timeline From Receipt of Tier Two Required Response/Action Sampling Results Continuously i. Document the exceedance and each required response/action in the SWPPP in accordance with E-6(c) above. Within two weeks ii. Notify the Division's Regional Office in writing of the exceedance date and value. iii. Conduct a stormwater management inspection. iv. Identify and evaluate possible causes of the benchmark exceedance. Within one month v. Select specific,feasible courses of action to reduce concentrations of the parameter(s) of concern including,but not limited to,source controls,operational controls,or physical improvements. Within two months vi. Implement the selected feasible actions. vii. Implement monthly monitoring at every outfall where a sampling result exceeded the benchmark value for two consecutive samples for all parameters until three samples in a row are below the benchmark value. E-7. Tier Three Response: Four Benchmark Exceedances Within the Permit Term The facility will remain in Tier Three status until three consecutive samples are under the benchmark or are inside the benchmark range for all parameters. Page 14 of 31 Permit No.NCG030000 (a) If any four sampling results within the permit term for any single parameter are above the benchmark value at a sampled outfall,then the permittee shall respond in accordance with Table 5 to identify and address the source of exceedances for that parameter at that outfall. (b) The permittee shall prepare a written Action Plan and submit to the Division's Regional Office for review and approval within thirty(30) days of receipt of the fourth analytic monitoring data point that exceeds the benchmark value. At a minimum,the Action Plan shall include: i. documentation of the four benchmark exceedances, ii. an inspection report that covers the industrial activities within the drainage area of the outfall with the exceedances (including the date of the inspection and the personnel conducting the inspection), iii. an evaluation of standard operating procedures and good housekeeping procedures, iv. identification of the source(s) of exceedances, V. specific actions that will be taken to remedy the identified source(s) with a schedule for completing those actions,and vi. a monitoring plan to verify that the Action Plan has addressed the source(s). (c) The permittee shall keep the Action Plan in the SWPPP and document when each specific action was carried out and by whom. (d) The permittee shall contact the Division's Regional Office when all actions in the Action Plan are completed. (e) The Tier Three response shall be in accordance with Table 5 below. Table 5: Tier Three Response for Four Benchmark Exceedances Within the Permit Term Timeline From Receipt of Fourth Tier Three Required Response/Action Sampling Result Continuously i. Document the exceedances and each required response/action in the SWPPP in accordance with E-7(c) above. ii. Implement or continue monthly monitoring for all parameters at the subject outfall and continue until three samples in a row are below the benchmark value. Within two weeks iii. Notify the Division's Regional Office in writing of the affected outfall, four exceedance dates and values. iv. Conduct a stormwater management inspection. v. Identify and evaluate possible causes of the benchmark exceedance. Within one month vi. Prepare an Action Plan that should include specific,feasible courses of action to reduce concentrations of the parameter(s) of concern including,but not limited to,source controls, operational controls,or physical improvements and submit to the Division's Regional Office for review and approval. Upon DEQ Approval vii. Implement the approved Action Plan. Upon Completion of Approved Action viii.Notify the Division's Regional Office of Action Plan completion. Plan Page 15 of 31 Permit No.NCG030000 PART F: SUBMITTAL OF DISCHARGE MONITORING REPORTS (DMRs) F-1. Deadlines for Submittal of Discharge Monitoring Reports Discharge Monitoring Reports (DMRs) shall be submitted in accordance with Table 6 below. For COCs issued between March 1-31,June 1-30,September 1-30, or Dec 1-31,sampling shall not commence until the next sampling period following initial issuance of the COC. Table 6: Reporting Requirements Monitoring Period DMR Type Deadline Notes July 1, 2021 -Sep 30, 2021 Paper' 30 days after the The deadline to register in monitoring period ends eDMR is Aug 1,2021 Oct 1, 2021 - Dec 31, 2021 Paper' 30 days after the monitoring period ends Jan 1, 2022 -Mar 30, 2022 Electronic2 30 days after the The deadline to report in and all subsequent monitoring period ends eDMR is Jan 1, 2022 monitoring periods ' Paper DMRs will be submitted in accordance with F-2. 2 Electronic DMRs will be submitted in accordance with F-3. F-2. Submittal Process before Electronic Discharge Monitoring Reporting(eDMR) Prior to eDMR,samples analyzed in accordance with the terms of this General Permit shall be reported as follows: (a) Sample results shall be recorded on Discharge Monitoring Report(DMR) forms provided by the Director. DMR forms are available on the Division's website httl2s:IIdeq.nc.gov/about/divisions/energy-mineral-land-resources/npdes-industrial- stormwater.) (b) DMRs shall be signed and certified by a person meeting the Signatory requirements in HH1. (c) Original,signed DMR forms shall be scanned and uploaded to the electronic DMR submittal form,which can be found by typing"deq.nc.gov/SW-Industrial"into a browser window and hitting"enter." (d) Then,the original signed DMR Forms shall be mailed or otherwise delivered to the appropriate Regional Office,which is indicated at: https://deq.nc.gov/contact/regional- offices . F-3. Submittal Process after Electronic Discharge Monitoring Reporting(eDMR) Unless otherwise informed by the Director,permittees shall register in eDMR prior to August 1, 2021 and shall begin reporting discharge monitoring data using eDMR prior to or on January 1, 2022.Information about eDMR can be found by typing"https://deg.nc.gov/deq.nc.gov/sw-edmr" into a browser window and hitting"enter." F-4. Results Below Detection Limits When results are below detection limit,they shall be reported in the format,"<XX mg/L,"where XX is the numerical value of the detection limit. Page 16 of 31 Permit No.NCG030000 F-5. Occurrences of No Discharge If no discharge occurs during the sampling period,the permittee must record within 30 days of the end of the sampling period in the facility's monitoring records."No Flow"or"No Discharge" shall be reported on the Discharge Monitoring Report (DMR). F-6. Reports if More Frequent Monitoring Has Occurred If the permittee monitors any pollutant more frequently than required by this General Permit using test procedures approved under 40 CFR Part 136 and at a sampling location specified in this General Permit,the results of such monitoring shall be included in the data submitted on the DMR. Analytical results within the monitoring period shall be submitted no later than 30 days from the date the facility receives all the sampling results. For purposes of benchmark comparison and Tiered response actions,the permittee shall use the analytical results from the first sample with valid results. The permittee is encouraged to take more samples than required during a monitoring period to help identify potential causes of exceedances. When taking additional samples,the permittee may not use the additional sample with lowest results for compliance purposes to avoid taking actions to identify causes of parameter exceedances.Additional sampling is only for informational purposes. F-7. Report if Begin Discharging to a Waterbody Not Listed on the COC The permittee shall request a modification to the COC from the Division prior to discharging from a new SDO to a waterbody that is not listed on the most current COC. F-8. Qualitative Monitoring Reports The permittee shall record the required qualitative monitoring observations on the SDO Qualitative Monitoring Report form provided by the Division and shall retain the completed forms on site. Qualitative monitoring results shall not be submitted to the Division, except upon the Division's specific requirement to do so. Qualitative Monitoring Report forms are available on the Division's website (httl2s://deq.nc.gov/about/divisions/energy-mineral-land-resources/npdes-stormwater- gp—s) F-9. Monitoring Report Retention Copies of the following reports shall be maintained on site or be available electronically to the Division upon request.These records or copies shall be maintained for a period of at least 5 years from the date of the sample,measurement,report or Notice of Intent application.This period may be extended by request of the Director at any time [40 CFR 122.41]. (a) Calibration and maintenance records, (b) Original strip chart recordings for continuous monitoring instrumentation, (c) Discharge Monitoring Reports (DMRs) and eDMR or other electronic DMR report submissions, (d) Visual monitoring records,and (e) Copies of all data used to complete the Notice of Intent to be covered by this General Permit. Page 17 of 31 Permit No.NCG030000 PART G: OTHER OCCURENCES THAT MUST BE REPORTED After a permittee becomes aware of an occurrence that must be reported,the permittee shall contact the appropriate Division regional office within the timeframes and in accordance with the other requirements listed in Table 7 below. Occurrences outside normal business hours may also be reported to the Department's Environmental Emergency Center personnel at(800) 858-0368. Table 7: Other Occurrences that Shall Be Reported Occurrence Reporting Timeframes (After Discovery) and Other Requirements Visible sedimentation in a stream (a) Within 24 hours,an oral or electronic notification. or wetland (b) Within 7 calendar days,a report that contains a description of the sediment and actions taken to address the cause of the deposition. Division staff may waive the requirement for a written report on a case-by-case basis. (c) If the stream is listed as impaired on the DWR Integrated Report for sediment-related causes,the permittee may be required to perform additional monitoring,inspections or apply more stringent practices if staff determine that additional requirements are needed to assure compliance with the federal or state impaired-waters conditions. Oil spills if they are: • 25 gallons or more, • less than 25 gallons but cannot be cleaned up within 24 hours, (d) Within 24 hours,an oral or electronic notification. The notification shall include information about the date,time,nature, • cause sheen on surface waters volume and location of the spill or release. (regardless of volume),or • within 100 feet of surface waters (regardless of volume) Releases of hazardous substances in excess of reportable quantities under Section 311 of the Clean (e) Within 24 hours,an oral or electronic notification. The Water Act Ref: 40 CFR 110.3and 40 notification shall include information about the date,time,nature, CFR 117.3) or section 102 of volume and location of the spill or release. CERCLA(Ref: 40 CFR 302.4) or G.S. 143-215.85 Anticipated bypasses (f) A report at least ten days before the date of the bypass, if [40 CFR 122.41(m)(3)] possible. The report shall include an evaluation of the anticipated quality and effect of the bypass. Unanticipated bypasses (g) Within 24 hours,an oral or electronic notification. [40 CFR 122.41(m)(3)] (h) Within 7 calendar days,a report that includes an evaluation of the quality and effect of the bypass. Noncompliance with the (i) Within 24 hours,an oral or electronic notification. conditions of this permit that may (j) Within 7 calendar days,a report that contains a description of the endanger health or the noncompliance,and its causes;the period of noncompliance, environment including exact dates and times,and if the noncompliance has not [40 CFR 122.41(1)(7)] been corrected,the anticipated time noncompliance is expected to continue; and steps taken or planned to reduce,eliminate,and prevent reoccurrence of the noncompliance. [40 CFR 122.41(1)(6). (k) Division staff may waive the requirement for a written report on a case-by-case basis. Page 18 of 31 Permit No.NCG030000 PART H: PERMIT ADMINISTRATION H-1. Signatory Requirements All applications,reports,or information submitted to the Permit Issuing Authority shall be signed and certified [40 CFR 122.41(k)]. (a) All Notices of Intent to be covered under this General Permit shall be signed as follows: i. For a corporation: by a responsible corporate officer. For the purpose of this Section,a responsible corporate officer means: (a) a president,secretary, treasurer or vice president of the corporation in charge of a principal business function,or any other person who performs similar policy or decision making functions for the corporation,or(b)the manager of one or more manufacturing,production,or operating facilities,provided,the manager is authorized to make management decisions which govern the operation of the regulated facility including having the explicit or implicit duty of making major capital investment recommendations,and initiating and directing other comprehensive measures to assure long term environmental compliance with environmental laws and regulations;the manager can ensure that the necessary systems are established or actions taken to gather complete and accurate information for permit application requirements; and where authority to sign documents has been assigned or delegated to the manager in accordance with corporate procedures. ii. For a partnership or sole proprietorship:by a general partner or the proprietor,respectively; or iii. For a municipality,State,Federal,or other public agency: by either a principal executive officer or ranking elected official [40 CFR 122.22]. (b) All reports required by this General Permit and other information requested by the Permit Issuing Authority shall be signed by a person described in paragraph (a) above or by a duly authorized representative of that person.A person is a duly authorized representative only if: i. The authorization is made in writing by a person described above; ii. The authorization specified either an individual or a position having responsibility for the overall operation of the regulated facility or activity, such as the position of plant manager, operator of a well or well field, superintendent,a position of equivalent responsibility,or an individual or position having overall responsibility for environmental matters for the company. (A duly authorized representative may thus be either a named individual or any individual occupying a named position.); and iii. The written authorization is submitted to the Permit Issuing Authority [40 CFR 122.22]. (c) Changes to authorization: If an authorization under paragraph (b) of this section is no longer accurate because a different individual or position has responsibility for the overall operation of the facility,a new authorization satisfying the requirements of paragraph (b) of this section must be submitted to the Director prior to or together with any reports, information,or applications to be signed by an authorized representative [40 CFR 122.22]. Page 19 of 31 Permit No.NCG030000 (d) Any person signing a document under paragraphs (a) or (b) of this section,or submitting an electronic report (e.g., eDMR), shall make the following certification [40 CFR 122.22]. No other statements of certification will be accepted. "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that quali fed personnel properly gather and evaluate the information submitted.Based on my inquiry of the person or persons who manage the system, or those persons directly responsible forgathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." H-2. General Permit Expiration General permits will be effective for a term not to exceed five years, at the end of which the Division may renew them after all public notice requirements have been satisfied.If a general permit is renewed,existing permittees do not need to submit a renewal request or pay a renewal fee unless directed by the Division. New applicants seeking coverage under a renewed general permit must submit a Notice of Intent (NOI) to be covered and obtain a Certificate of Coverage under the renewed general permit [15A NCAC 02H .0127(e)]. H-3. Planned Changes The permittee shall give notice to the Director as soon as possible of any planned changes at the permitted facility which could significantly alter the nature or quantity of pollutants discharged [40 CFR 122.41(1)].This notification requirement includes pollutants which are not specifically listed in the General Permit or subject to notification requirements under 40 CFR Part 122.42 (a). H-4. Transfers This General Permit is not transferable to any person without prior written notice to and approval from the Director in accordance with 40 CFR 122.61.The Director may condition approval in accordance with NCGS 143-215.1,in particular NCGS 143-215.1(b)(4)b.2., and may require modification or revocation and reissuance of the Certificate of Coverage,or a minor modification,to identify the new permittee and incorporate such other requirements as may be necessary under the CWA [40 CFR 122.41(1)(3), 122.61] or state statute.The permittee is required to notify the Division in writing in the event the permitted facility is sold or closed. H-5. When an Individual Permit May be Required The Director may require any owner/operator authorized to discharge under a Certificate of Coverage issued pursuant to this General Permit to apply for and obtain an individual permit or an alternative general permit.Any interested person may petition the Director to take action under this paragraph. Cases where an individual permit may be required include,but are not limited to, the following: (a) The discharger is a significant contributor of pollutants; (b) Conditions at the permitted site change,altering the constituents and/or characteristics of the discharge such that the discharge no longer qualifies for a general permit; (c) The discharge violates the terms or conditions of this General Permit; (d) A change has occurred in the availability of demonstrated technology or practices for the control or abatement of pollutants applicable to the point source; (e) Effluent limitations are promulgated for the point sources covered by this General Permit; Page 20 of 31 Permit No.NCG030000 (f) A water quality management plan containing requirements applicable to such point sources is approved after the issuance of this General Permit; (g) The Director determines at his or her own discretion that an individual permit is required. H-6. When an Individual Permit May be Requested Any permittee operating under this General Permit may request to be excluded from the coverage of this General Permit by applying for an individual permit.When an individual permit is issued to an owner/operator the applicability of this General Permit is automatically terminated on the effective date of the individual permit. H-7. General Permit Modification, Revocation and Reissuance, or Termination The issuance of this General Permit does not prohibit the Permit Issuing Authority from reopening and modifying the General Permit,revoking and reissuing the General Permit,or terminating the General Permit as allowed by the laws,rules,and regulations contained in Title 40, Code of Federal Regulations,Parts 122 and 123; Title 15A of the North Carolina Administrative Code,Subchapter 2H .0100; and North Carolina General Statute 143-215.1 et al. After public notice and opportunity for a hearing,the General Permit may be terminated for cause.The filing of a request for a General Permit modification,revocation and reissuance,or termination does not stay any General Permit condition.The Certificate of Coverage shall expire when the General Permit is terminated. H-8. Certificate of Coverage Actions Coverage under the General Permit may be modified,revoked and reissued, or terminated for cause. The notification of planned changes or anticipated noncompliance does not stay any General Permit condition [40 CFR 122.41(f)]. H-9. Requirement to Report Incorrect Information Where the permittee becomes aware that it failed to submit any relevant facts in a Notice of Intent to be covered under this General Permit, or submitted incorrect information in that Notice of Intent application or in any report to the Director,it shall promptly submit such facts or information [40 CFR 122.41(1)(8)]. H-10. Waivers from Electronic Reporting If a permittee is unable to use the eDMR system due to a demonstrated hardship or due to the facility being physically located in an area where less than 10 percent of the households have broadband access,then a temporary waiver from the NPDES electronic reporting requirements may be granted and discharge monitoring data may be submitted on paper DMR forms or alternative forms approved by the Director. To obtain a temporary electronic reporting waiver,the permittee must first submit an electronic reporting waiver request to the Division. Requests for temporary electronic reporting waivers must be submitted in writing to the Division for written approval at least sixty(60) days prior to the date the facility would be required under this permit to begin submitting monitoring data and reports. The duration of a temporary waiver shall not exceed 5 years and shall thereupon expire. At such time,monitoring data and reports shall be submitted electronically to the Division unless the permittee re-applies for and is granted a new temporary electronic reporting waiver by the Division. Approved electronic reporting waivers are not transferrable. Only permittees with an approved reporting waiver request may submit monitoring data and reports on paper to the Division for the period that the approved reporting waiver request is effective. Page 21 of 31 Permit No.NCG030000 Information on eDMR and the application for a temporary electronic reporting waiver are found on the following web page: https:lldeq.nc.gov/about/divisions/water-resources/edmr H-11. Annual Administering and Compliance Monitoring Fee Requirements The permittee must pay the administering and compliance monitoring fee within 30 (thirty) days after being billed by the Division. Failure to pay the fee in timely manner in accordance with 15A NCAC 2H .0105(b)(2) may cause the Division to initiate action to revoke coverage under the General Permit. H-12. Flow Measurements Where required,appropriate flow measurement devices and methods consistent with accepted scientific practices shall be selected and used to ensure the accuracy and reliability of measurements of the volume of monitored discharges. H-13. Test Procedures Test procedures for the analysis of pollutants shall conform to the EMC regulations published pursuant to NCGS 143-215.63 et.seq,the Water and Air Quality Reporting Acts,and to regulations published pursuant to Section 304(g), 33 USC 1314, of the Federal Water Pollution Control Act,as Amended,and Regulation 40 CFR 136. To meet the intent of the monitoring required by this General Permit,all test procedures must produce minimum detection and reporting levels and all data generated must be reported down to the minimum detection or lower reporting level of the procedure. If no approved methods are determined capable of achieving minimum detection and reporting levels below the General Permit discharge requirements,then the most sensitive (method with the lowest possible detection and reporting level) approved method must be used. H-14. Availability of Reports Except for data determined to be confidential under NCGS 143-215.3(a)(2) or Section 308 of the Federal Clean Water Act, 33 USC 1318, all reports prepared in accordance with the terms shall be available for public inspection at the offices of the Division. As required by the Act,analytical data shall not be considered confidential. Knowingly making any false statement on any such report may result in the imposition of criminal penalties as provided for in NCGS 143-215.613 or in Section 309 of the Federal Clean Water Act. Page 22 of 31 Permit No.NCG030000 PART I: COMPLIANCE AND LIABILITY I-1. Compliance Schedule The permittee shall comply with Limitations and Controls specified for stormwater discharges in accordance with the following schedule: (a) Existing Facilities already operating but applying for permit coverage for the first time: The Stormwater Pollution Prevention Plan shall be developed and implemented within 12 months of the effective date of the Certificate of Coverage and updated thereafter on an annual basis.Secondary containment,as specified in B-8 of this General Permit,shall be accomplished within 12 months of the effective date of the issuance of the Certificate of Coverage. (b) New Facilities applying for coverage for the first time: The Stormwater Pollution Prevention Plan shall be developed and implemented prior to the beginning of discharges from the operation of the industrial activity and be updated thereafter on an annual basis. Secondary containment,as specified in Part B of this General Permit shall be accomplished prior to the beginning of discharges from the operation of the industrial activity. (c) Existing facilities previously permitted and applying for renewal under this General Permit: All requirements,conditions,limitations,and controls contained in this permit(except new SWPPP elements in this permit renewal) shall become effective immediately upon issuance of the Certificate of Coverage.New elements of the Stormwater Pollution Prevention Plan for this permit renewal shall be developed and implemented within 6 months of the effective date of this General Permit and updated thereafter on an annual basis.Secondary containment,as specified in Part B of this General Permit shall be accomplished prior to the beginning of discharges from the operation of the industrial activity. I-2. Duty to Comply The permittee must comply with all conditions of this General Permit.Any permit noncompliance constitutes a violation of the Clean Water Act (CWA) and is grounds for enforcement action; for permit termination,revocation and reissuance,or modification; or denial of a permit upon renewal application [40 CFR 122.41]. (a) The permittee shall comply with standards or prohibitions established under section 307(a) of the CWA for toxic pollutants within the time provided in the regulations that establish these standards or prohibitions, even if the General Permit has not yet been modified to incorporate the requirement [40 CFR 122.41]. (b) The CWA provides that any person who violates section[s] 301, 302, 306, 307, 308, 318 or 405 of the Act,or any permit condition or limitation implementing any such sections in a permit issued under section 402, or any requirement imposed in a pretreatment program approved under sections 402(a)(3) or 402(b)(8) of the Act,is subject to a civil penalty not to exceed$51,570 per day for each violation [33 USC 1319(d) and 40 CFR 122.41(a)(2)]. (c) The CWA provides that any person who negligently violates sections 301, 302, 306, 307, 308, 318, or 405 of the Act, or any condition or limitation implementing any of such sections in a permit issued under section 402 of the Act, or any requirement imposed in a pretreatment program approved under section 402(a)(3) or 402(b)(8) of the Act,is subject to criminal penalties of$2,500 to $25,000 per day of violation,or imprisonment of not more than 1 year, or both. In the case of a second or subsequent conviction for a negligent violation,a person shall be subject to criminal penalties of not more than $50,000 per day of violation,or by imprisonment of not more than 2 years, or both [33 USC 1319(c)(1) and 40 CFR 122.41(a)(2)]. Page 23 of 31 Permit No.NCG030000 (d) Any person who knowingly violates such sections,or such conditions or limitations is subject to criminal penalties of$5,000 to$50,000 per day of violation, or imprisonment for not more than 3 years, or both. In the case of a second or subsequent conviction for a knowing violation,a person shall be subject to criminal penalties of not more than$100,000 per day of violation,or imprisonment of not more than 6 years, or both [33 USC 1319(c)(2) and 40 CFR 122.41(a)(2)]. (e) Any person who knowingly violates section 301, 302, 303, 306, 307, 308, 318 or 405 of the Act,or any permit condition or limitation implementing any of such sections in a permit issued under section 402 of the Act,and who knows at that time that he thereby places another person in imminent danger of death or serious bodily injury,shall,upon conviction, be subject to a fine of not more than $250,000 or imprisonment of not more than 15 years, or both.In the case of a second or subsequent conviction for a knowing endangerment violation,a person shall be subject to a fine of not more than $500,000 or by imprisonment of not more than 30 years, or both.An organization,as defined in section 309(c)(3)(B)(iii) of the CWA,shall,upon conviction of violating the imminent danger provision,be subject to a fine of not more than$1,000,000 and can be fined up to$2,000,000 for second or subsequent convictions [40 CFR 122.41(a)(2)]. (f) Under state law,a civil penalty of not more than $25,000 per violation may be assessed against any person who violates or fails to act in accordance with the terms,conditions, or requirements of a permit [North Carolina General Statutes § 143-215.6A]. (g) Any person may be assessed an administrative penalty by the Administrator for violating section 301, 302, 306, 307, 308, 318 or 405 of this Act, or any permit condition or limitation implementing any of such sections in a permit issued under section 402 of this Act. Administrative penalties for Class I violations are not to exceed$20,628 per violation,with the maximum amount of any Class I penalty assessed not to exceed$51,570. Penalties for Class II violations are not to exceed $20,628 per day for each day during which the violation continues,with the maximum amount of any Class II penalty not to exceed $257,848. [33 USC 1319(g)(2) and 40 CFR 122.41(a)(3)]. I-3. Duty to Mitigate The permittee shall take all reasonable steps to minimize or prevent any discharge in violation of this General Permit which has a reasonable likelihood of adversely affecting human health or the environment [40 CFR 122.41(d)]. I-4. Civil and Criminal Liability Except as provided in Part C-6 of this General Permit regarding bypassing of stormwater control facilities,nothing in this permit shall be construed to relieve the permittee from any responsibilities,liabilities, or penalties for noncompliance pursuant to NCGS 143-215.3,143-215.6, or Section 309 of the Federal Act, 33 USC 1319. Furthermore,the permittee is responsible for consequential damages,such as fish kills, even though the responsibility for effective compliance may be temporarily suspended. I-5. Oil and Hazardous Substance Liability Nothing in this General Permit shall be construed to preclude the institution of any legal action or relieve the permittee from any responsibilities,liabilities,or penalties to which the permittee is or may be subject to under NCGS 143-215.75 et seq. or Section 311 of the Federal Act, 33 USC 1321. Page 24 of 31 Permit No.NCG030000 I-6. Property Rights The issuance of this General Permit does not convey any property rights in either real or personal property,or any exclusive privileges,nor does it authorize any injury to private property or any invasion of personal rights,nor any infringement of Federal,State, or local laws or regulations [40 CFR 122.41(g)]. I-7. Severability The provisions of this General Permit are severable, and if any provision of this General Permit,or the application of any provision of this General Permit to any circumstances,is held invalid,the application of such provision to other circumstances,and the remainder of this General Permit, shall not be affected thereby [NCGS 15013-23]. I-8. Duty to Provide Information The permittee shall furnish to the Permit Issuing Authority,within a reasonable time,any information which the Permit Issuing Authority may request to determine whether cause exists for modifying,revoking and reissuing, or terminating the COC issued pursuant to this General Permit or to determine compliance with this General Permit.The permittee shall also furnish to the Permit Issuing Authority upon request, copies of records required to be kept by this General Permit [40 CFR 122.41(h)]. I-9. Penalties for Tampering The Clean Water Act provides that any person who falsifies,tampers with,or knowingly renders inaccurate,any monitoring device or method required to be maintained under this General Permit shall,upon conviction,be punished by a fine of not more than$10,000 per violation,or by imprisonment for not more than two years per violation,or by both.If a conviction of a person is for a violation committed after a first conviction of such person under this paragraph,punishment is a fine of not more than$20,000 per day of violation, or by imprisonment of not more than 4 years,or both [40 CFR 122.41]. I-10. Penalties for Falsification of Reports The Clean Water Act provides that any person who knowingly makes any false statement, representation,or certification in any record or other document submitted or required to be maintained under this General Permit,including monitoring reports or reports of compliance or noncompliance shall,upon conviction,be punished by a fine of not more than$10,000 per violation, or by imprisonment for not more than two years per violation,or by both [40 CFR 122.41]. I-11. Onshore or Offshore Construction This General Permit does not authorize or approve the construction of any onshore or offshore physical structures or facilities or the undertaking of any work in any navigable waters. I-12. Duty to Reapply Dischargers covered by this General Permit need not submit a new Notice of Intent(NOI) or renewal request unless so directed by the Division. If the Division chooses not to renew this General Permit,the permittee will be notified to submit an application for an individual permit [15A NCAC 02H .0127(e)]. Page 25 of 31 Permit No.NCG030000 I-13. Inspection and Entry The permittee shall allow the Director,or an authorized representative (including an authorized contractor acting as a representative of the Director),or in the case of a facility which discharges through a municipal separate storm sewer system,an authorized representative of a municipal operator or the separate storm sewer system receiving the discharge,upon the presentation of credentials and other documents as may be required by law,to: (a) Enter upon the permittee's premises where a regulated facility or activity is located or conducted,or where records must be kept under the conditions of this General Permit; (b) Have access to and copy,at reasonable times,any records that must be kept under the conditions of this General Permit; (c) Inspect at reasonable times any facilities,equipment (including monitoring and control equipment),practices,or operations regulated or required under this General Permit;and (d) Sample or monitor at reasonable times,for the purposes of assuring permit compliance or as otherwise authorized by the Clean Water Act,any substances or parameters at any location [40 CFR 122.41(i)]. I-14. Need to Halt or Reduce Not a Defense It shall not be a defense for a permittee in an enforcement action that it would have been necessary to halt or reduce the permitted activity in order to maintain compliance with the condition of this General Permit [40 CFR 122.41(c)]. Page 26 of 31 Permit No.NCG030000 PART J: DEFINITIONS Additional definitions for the NPDES Program may be found in federal rule at 40 CFR Part 122.2 Act See Clean Water Act. Adverse Weather Weather conditions are those that are dangerous or create inaccessibility for personnel,such as local flooding,high winds, or electrical storms, or situations that otherwise make sampling impractical. When adverse weather conditions prevent the collection of samples during the sample period,the permittee must take a substitute sample or perform a visual assessment during the next qualifying storm event. Documentation of an adverse event(with date,time,and written narrative) and the rationale must be included with your SWPPP records.Adverse weather does not exempt the permittee from having to file a monitoring report in accordance with the sampling schedule. Adverse events and failures to monitor must also be explained and reported on the relevant DMR. Allowable Non-Stormwater Discharges This General Permit regulates stormwater discharges. Non-stormwater discharges which shall be allowed in the stormwater conveyance system include: (a) All other discharges that are authorized by a non-stormwater NPDES permit. (b) Uncontaminated groundwater,foundation drains,air-conditioner condensate without added chemicals,springs,discharges of uncontaminated potable water,waterline and fire hydrant flushings,water from footing drains,irrigation waters,flows from riparian habitats and wetlands. (c) Discharges resulting from fire-fighting,or emergency shower oreye wash as a result of use in the event of an emergency. Best Management Practices(BMPs) Measures or practices used to reduce the amount of pollution entering surface waters. BMPs may take the form of a process,activity, or physical structure. More information on BMPs can be found at: httl2s://www.epa.gov/npdes/national-menu-best-management-practices-bmps- stormwater#edu. Bulk Storage of Liquid Materials Liquid raw materials,in-process liquids and reactants,manufactured products,waste materials or by-products contained in a single above ground container,tank,or vessel having a capacity of greater than 660 gallons or contained in multiple above ground containers,tanks, or vessels located in close proximity to each other having a total combined capacity of greater than 1,320 gallons. Bypass The known diversion of stormwater from any portion of a control facility including the collection system,or the diversion of waste streams from any portion of a treatment facility including the collection system,which is not a designed or established operating mode for the facility. Certificate of Coverage(COC) The cover sheet which accompanies a general permit upon issuance and lists the facility name, location,receiving stream,river basin, effective date of coverage under the general permit,and is signed by the Director. Page 27 of 31 Permit No.NCG030000 Clean Water Act(CWA) The Federal Water Pollution Control Act,also known as the Clean Water Act,as amended, 33 USC 1251,et.seq. Division The Division of Energy,Mineral, and Land Resources, Department of Environmental Quality(DEQ), formerly the Department of Environment and Natural Resources. Director The Director of the Division of Energy, Mineral, and Land Resources,the permit issuing authority. EMC The North Carolina Environmental Management Commission. Grab Sample An individual sample collected instantaneously. Grab samples that will be analyzed (analytically or qualitatively) should be taken within the first 30 minutes of discharge. Hazardous Substance Any substance designated under 40 CFR Part 116 pursuant to Section 311 of the Clean Water Act. High Quality Waters(HQW) Supplemental classification intended to protect waters which are rated excellent based on biological and physical/chemical characteristics through Division monitoring or special studies, or HQW by definition: (a) Water Supply Watershed I (WS-I), (b) Water Supply Watershed II (WS-II), (c) SA waters (commercial shellfish), (d) Outstanding Resource Waters (ORW), (e) Primary Nursery Areas and other functional nursery areas designated by Marine Fisheries Commission,or (f) Waters for which the Division of Water Resources has received a petition for reclassification to either WS-I or WS-II (15A NCAC 02B .0200). Impaired Water A water that has one or more parameters (biological and/or chemical) that exceed water quality standards. Measurable Storm Event A storm event that results in an actual discharge from the permitted site outfall. Municipal Separate Storm Sewer System (MS4) A stormwater collection system within an incorporated area of local self-government such as a city or town. Page 28 of 31 Permit No.NCG030000 No Exposure A condition of no exposure means that all industrial materials and activities are protected by a storm resistant shelter or acceptable storage containers to prevent exposure to rain,snow, snowmelt,or runoff. Industrial materials or activities include,but are not limited to,material handling equipment or activities,industrial machinery,raw materials,intermediate products,by- products,final products,or waste products.The Division's Regional Office may grant a No Exposure Exclusion from NPDES stormwater permitting requirements only if a facility complies with the terms and conditions described in 40 CFR§122.26(g). Notice oflntent(NOI) The state application form which,when submitted to the Division,officially indicates the facility's notice of intent to seek coverage under a general permit. Outstanding Resource Water(ORW) Supplemental classification intended to protect unique and special waters having excellent water quality and being of exceptional state or national,ecological or recreational significance.To qualify, waters must be rated Excellent by DWQ, and have one of the following outstanding resource values: (a) Outstanding fish habitat and fisheries, (b) Unusually high level of water-based recreation or potential for such kind of recreation, (c) Some special designation such as N.C. Scenic/Natural River,or National Wildlife Refuge, (d) Important component of state or national park or forest; or (e) Special ecological or scientific significance (rare or endangered species habitat,research or educational areas). All ORWs are HQW by supplemental classification. (15A NCAC 02B .0200) Permit Issuing Authority The Director of the Division of Energy, Mineral, and Land Resources (see"Director"above). Permittee The owner or operator issued a Certificate of Coverage pursuant to this General Permit. Point Source Discharge of Stormwater Any discernible,confined and discrete conveyance including,but not specifically limited to,any pipe,ditch,channel, conduit,well, or discrete fissure from which stormwater is or may be discharged to waters of the State. Primary Nursery Area(PNA) Tidal saltwaters which provide essential habitat for the early development of commercially important fish and shellfish and are so designated by the Marine Fisheries Commission. (15A NCAC 02B .0200) Representative Outfall Status(ROS) When it is established that the discharge of stormwater runoff from a single outfall is representative of the discharges at multiple outfalls,the Division's Regional Office may grant representative outfall status.ROS allows the permittee to perform analytical monitoring at a reduced number of outfalls. Page 29 of 31 Permit No.NCG030000 Secondary Containment Spill containment for the contents of the single largest tank within the containment structure plus sufficient freeboard to contain the 25-year, 24-hour storm event. Section 313 Water Priority Chemical A chemical or chemical category which: (a) Is listed in 40 CFR 372.65 pursuant to Section 313 of Title III of the Superfund Amendments and Reauthorization Act(SARA) of 1986, also titled the Emergency Planning and Community Right-to-Know Act (EPCRA) of 1986; (b) Is present at or above threshold levels at a facility subject to SARA title III,Section 313 reporting requirements; and (c) Meets at least one of the following criteria: • Is listed in appendix D of 40 CFR Part 122 on Table II (organic priority pollutants),Table III (certain metals,cyanides,and phenols) or Table IV(certain toxic pollutants and hazardous substances); • Is listed as a hazardous substance pursuant to section 311(b)(2)(A) of the CWA at 40 CFR 116.4; or • Is a pollutant for which EPA has published acute or chronic water quality criteria. Severe Property Damage Substantial physical damage to property,damage to the control facilities which causes them to become inoperable,or substantial and permanent loss of natural resources which can reasonably be expected to occur in the absence of a bypass.Severe property damage does not mean economic loss caused by delays in production. Significant Materials Includes,but is not limited to: raw materials; fuels; materials such as solvents,detergents,and plastic pellets; finished materials such as metallic products; raw materials used in food processing or production; hazardous substances designated under section 101(14) of CERCLA; any chemical the facility is required to report pursuant to section 313 of Title III of SARA; fertilizers;pesticides; and waste products such as ashes,slag, and sludge that have the potential to be released with stormwater discharges. Significant Spills Includes,but is not limited to: releases of oil or hazardous substances in excess of reportable quantities under section 311 of the Clean Water Act (Ref: 40 CFR 110.3 and 40 CFR 117.3) or section 102 of CERCLA(Ref: 40 CFR 302.4). Stormwater Control Measure(SCM) A permanent structural device that is designed,constructed,and maintained to remove pollutants from stormwater runoff by promoting settling or filtration; or to mimic the natural hydrologic cycle by promoting infiltration, evapo-transpiration,post-filtration discharge,reuse of stormwater,or a combination thereof. Stormwater Discharge Outfall(SDO) The point of departure of stormwater from a discernible,confined,or discrete conveyance, including but not limited to,storm sewer pipes,drainage ditches, channels,spillways, or channelized collection areas,from which stormwater flows directly or indirectly into waters of the State. Page 30 of 31 Permit No.NCG030000 Stormwater Runoff The flow of water which results from precipitation and which occurs immediately following rainfall or as a result of snowmelt. Stormwater Associated with Industrial Activity The discharge from any point source which is used for collecting and conveying stormwater and which is directly related to manufacturing,processing,or raw material storage areas at an industrial site. Facilities considered to be engaged in"industrial activities" include those activities defined in 40 CFR 122.26(b)(14).The term does not include discharges from facilities or activities excluded from the NPDES program. Stormwater Pollution Prevention Plan (SWPPP) A comprehensive site-specific plan which details measures and practices to reduce stormwater pollution and is based on an evaluation of the pollution potential of the site. Total Maximum Daily Load(TMDL) TMDLs are written plans for attaining and maintaining water quality standards,in all seasons,for a specific water body and pollutant.A list of approved TMDLs for the state of North Carolina can be found at https://deq.nc.gov/about/divisions/water-resources/12lanning/modeling- assessment/tmdls. Toxic Pollutant Any pollutant listed as toxic under Section 307(a)(1) of the Clean Water Act. Trout Water(Tr) Supplemental classification intended to protect freshwaters for natural trout propagation and survival of stocked trout on a year round basis.This is not the same as the N.C.Wildlife Resources Commission's Designated Public Mountain Trout Waters (15A NCAC 02B .0200). Upset An exceptional incident in which there is unintentional and temporary noncompliance with technology-based permit effluent limitations because of factors beyond the reasonable control of the permittee. An upset does not include noncompliance to the extent caused by operational error, improperly designed treatment or control facilities,inadequate treatment or control facilities,lack of preventive maintenance, or careless or improper operation. Vehicle Maintenance Activity Vehicle rehabilitation,mechanical repairs,washing,sanding,painting,fueling,lubrication,vehicle cleaning operations, or airport deicing operations. Visible Sedimentation Solid particulate matter,both mineral and organic,that has been or is being transported by water, air,gravity,or ice from its site of origin which can be seen with the unaided eye. 10 year,24-hour Storm Event The maximum 24-hour precipitation event expected to be equaled or exceeded,on the average, once in 10 years. 25 year,24-hour Storm Event The maximum 24-hour precipitation event expected to be equaled or exceeded,on the average, once in 25 years. Page 31 of 31 APPENDIX B PHOTOLOG GEOSYNTEC CONSULTANTS Geosyntec° Photographic Record �ons111cancs Client: Corning Optical Project Number: GN11195 Communications, LLC Site Name: Hickory Manufacturing Site Location: Hickory, North Carolina and Technology Center Photograph ID: 1 Date: 4/7/2025 Direction: E Comments: View of SDO 3 during , ^� active rainfall event. Discharging water was clear, leaf buildup around outfall but not on rip rap. - .r Photograph ID: 2 Date: 4/7/2025 ' Direction: SE ' Comments: Some yellowish green material buildup on SDO 3 outfall pipe. APPENDIX B-PHOTOLOG 1 April 2025 GEOSYNTEC CONSULTANTS Geosynte& consultants Photographic Record Client: Corning Optical Project Number: GN11195 Communications, LLC Site Name: Hickory Manufacturing Site Location: Hickory, North Carolina and Technology Center Photograph ID: 4 Date: 4/7/2025 Direction: E Ate►,' 1 Comments: Storm drain inlet#8. Ponding water, some leaf debris and minor sediment buildup on filter. Photograph ID: 5 Date: 4/7/2025 Direction: W Comments: Storm drain inlet#3 . 2 a R APPENDIX B-PHOTOLOG 2 April 2025 GEOSYNTEC CONSULTANTS Geosyntec° Photographic Record consultants Client: Corning Optical Project Number: GN11195 Communications, LLC Site Name: Hickory Manufacturing Site Location: Hickory, North Carolina and Technology Center Photograph ID: 6 Date: 4/7/2025 � " Direction: N/A Comments: Storm drain inlet#5. Some wood pieces from reel storage. S i m a -;f 00K.3 WMWr4106�3 Photograph ID: 7 1 � 3 Date: 4/7/2025 Direction: W Comments: Storm drain inlet#4. Some sediment accumulation and some ponding around drain. 1 APPENDIX B-PHOTOLOG 3 April 2025 GEOSYNTEC CONSULTANTS Geosyntec° Photographic Record �ons111cancs Client: Corning Optical Project Number: GN11195 Communications, LLC Site Name: Hickory Manufacturing Site Location: Hickory, North Carolina and Technology Center Photograph ID: 8 Date: 4/7/2025 Direction: W Comments: Storm drain inlet#6. Waft Photograph ID: 9 Date: 4/7/2025 Direction: NW Comments: Storm drain inlet north of storm drain inlet#6. Filter inside slowing flow of water through drain. 1" APPENDIX B-PHOTOLOG 4 April 2025 GEOSYNTEC CONSULTANTS Geosyntec° Photographic Record consultants Client: Corning Optical Project Number: GN11195 Communications, LLC Site Name: Hickory Manufacturing Site Location: Hickory, North Carolina and Technology Center Photograph ID: 10 Date: 4/7/2025 Direction: NW Comments: Storm drain inlet north of storm drain inlet#6. Filter inside ` �a slowing flow of water through drain. tea.. Mt �. Photograph ID: 11 Date: 4/7/2025 Direction: W d Comments: Storm drain inlet#7. Some leaf litter and sediment buildup. yam=• _. APPENDIX B-PHOTOLOG S April 2025 GEOSYNTEC CONSULTANTS Geosyntec° Photographic Record �ons111cancs Client: Corning Optical Project Number: GN11195 Communications, LLC Site Name: Hickory Manufacturing Site Location: Hickory, North Carolina and Technology Center Photograph ID: 12 Date: 4/7/2025 Direction: W Comments: Storm drain inlet#2. Standing water around inlet, wood and leaf debris around filter. } Photograph ID: 13 Date: 4/7/2025 Direction: N Comments: Storm drain inlet west of SDO 3. APPENDIX B-PHOTOLOG 6 April 2025 GEOSYNTEC CONSULTANTS Geosyntec° Photographic Record consultants Client: Corning Optical Project Number: GN11195 Communications, LLC Site Name: Hickory Manufacturing Site Location: Hickory, North Carolina and Technology Center Photograph ID: 14 Date: 4/7/2025 Direction: NE s Comments: Reel storage in Drainage v Area 3. APPENDIX B-PHOTOLOG April 2025 APPENDIX C SITE INSPECTION REPORT Site Inspection Report Site Name and Address: Corning Optical Communications, 1164 23rd Street SE,Hickory,North Carolina 28602 Inspector's Name and Phone Number: Anna Brand(804) 512-5542 Inspection Date: 4/7/2025 Inspection Areas Covered: Exterior of Drainage Area 3 Weather Conditions: Raining,60-70°F Outlet 3(SD03) Yes N/A No Comments Is staining visible in or around the outlet? X Some pollen/yellow material on pipe outlet Is a sheen,discoloration,or foam visible in the outlet? X Foam from turbulent water,no sheen or discoloration Is sediment buildup visible in or around the outlet? X No sediment buildup Is erosion visible in or around the outlet? X No erosion Is there an odor in or around the outlet? X No odor Discuss sampling procedures. Are any sediments or decomposing X Collected from pipe organic materials collected during sampling? Describe the physical characteristics of the outlet(size,standing water, 24"HDPE—water is currently discharging(to unnamed tributary to drainage receptor) Clark Creek) Drainage Area 3 Yes N/A No Comments Are fork lift track marks or other staining visible in the area? X No staining in drainage area Are wood or steel reels visible in the area?Are they empty or full? X Some empty and some full Are there trash bins or vehicle maintenance/fueling/parking in the area? X Trash bins under covered areas,no visible Is there any visible staining or residuals near these locations? staining Are there any other potential sources of pollution observed within the X Some minor leafy debris and pollen drainage area? throughout Describe industrial activities observed within the drainage area. Empty and full reel storage.Wooden reel and pallet storage. Describe building materials used within the drainage area. Wooden and plastic reels,PVC downspouts Storm Drain Inlet#1 Yes N/A No Comments Are fork lift track marks or other staining visible in or around the inlet? X No staining observed Is a sheen,discoloration,or foam visible in the inlet? X Could not locate inlet—beneath reel storage Is sediment buildup or dust visible in or around the inlet? X Could not locate inlet—beneath reel storage Is there trash/debris accumulation in or around the inlet? X Leafy debris and wood pieces in drainage area Is the impervious surface compromised in or around the inlet? X Could not locate inlet—beneath reel storage Is there an odor in or around the inlet? X No odor observed in drainage area Describe BMPs in place at the inlet. Could not locate drain inlet—beneath empty wooden reels (ie Metal Zorb filters,booms,filter socks,etc). GN11195 Pagel of 4 Geosyntec Consultants of NC,P.C. Site Inspection Report Storm Drain Inlet#2 Yes N/A No Comments Are forklift track marks or other staining visible in or around the inlet? X No staining observed Is a sheen,discoloration,or foam visible in the inlet? X None observed Is sediment buildup or dust visible in or around the inlet? X Sediment accumulation and pollen around filter Is there trash/debris accumulation in or around the inlet? X Some sticks,leaves Is the impervious surface compromised in or around the inlet? X Impervious surface is intact Is there an odor in or around the inlet? X No odor observed Describe BMPs in place at the inlet. Coconut fiber filter—pooling water around inlet (ie Metal Zorb filters,booms,filter socks,etc). Storm Drain Inlet#3 Yes N/A No Comments Are fork lift track marks or other staining visible in or around the inlet? X No staining observed Is a sheen,discoloration,or foam visible in the inlet? X None observed Is sediment buildup or dust visible in or around the inlet? X None observed Is there trash/debris accumulation in or around the inlet? X Very minimal leaf buildup on filter Is the impervious surface compromised in or around the inlet? X Impervious surface is intact Is there an odor in or around the inlet? X No odor observed Describe BMPs in place at the inlet. Coconut fiber filter (ie Metal Zorb filters,booms,filter socks,etc). Storm Drain Inlet#4 Yes N/A No Comments Are fork lift track marks or other staining visible in or around the inlet? X No staining observed Is a sheen,discoloration,or foam visible in the inlet? X None observed Is sediment buildup or dust visible in or around the inlet? X Minor sediment buildup Is there trash/debris accumulation in or around the inlet? X Minor leaf litter Is the impervious surface compromised in or around the inlet? X Impervious surface is intact Is there an odor in or around the inlet? X No odor observed Describe BMPs in place at the inlet. Filter inside of drain,some ponding around drain. (ie Metal Zorb filters,booms,filter socks,etc). Storm Drain Inlet#5 Yes N/A No Comments Are fork lift track marks or other staining visible in or around the inlet? X No staining observed GN11195 Page 2 of 4 Geosyntec Consultants of NC,P.C. Site Inspection Report Is a sheen,discoloration,or foam visible in the inlet? X None observed Is sediment buildup or dust visible in or around the inlet? X None observed Is there trash/debris accumulation in or around the inlet? X Some pieces of wood from reels Is the impervious surface compromised in or around the inlet? X Impervious surface is intact Is there an odor in or around the inlet? X No odor observed Describe BMPs in place at the inlet. Filter in drain (ie Metal Zorb filters,booms,filter socks,etc). Roof Drain(L Room) Yes N/A No Comments Are fork lift track marks or other staining visible in or around the inlet? X No staining observed Is a sheen,discoloration,or foam visible in the inlet? X None observed Is sediment buildup or dust visible in or around the inlet? X None observed Is there trash/debris accumulation in or around the inlet? X Minor trash below gutter(plastic) Is the impervious surface compromised in or around the inlet? X Impervious surface is intact Is there an odor in or around the inlet? X No odor observed Describe BMPs in place at the inlet. No flow from drain during rain event (ie Metal Zorb filters,booms,filter socks,etc). Storm Drain Inlet#6 Yes N/A No Comments Are fork lift track marks or other staining visible in or around the inlet? X No staining observed Is a sheen,discoloration,or foam visible in the inlet? X None observed Is sediment buildup or dust visible in or around the inlet? X Some sediment buildup near drain Is there trash/debris accumulation in or around the inlet? X Minor leaf debris Is the impervious surface compromised in or around the inlet? X Impervious surface is intact Is there an odor in or around the inlet? X No odor observed Describe BMPs in place at the inlet. (ie Metal Zorb filters,booms,filter socks,etc). Filter in drain,some standing water Storm Drain Inlet#7 Yes N/A No Comments Are fork lift track marks or other staining visible in or around the inlet? X No staining observed Is a sheen,discoloration,or foam visible in the inlet? X None observed Is sediment buildup or dust visible in or around the inlet? X None observed GN11195 Page 3 of 4 Geosyntec Consultants of NC,P.C. Site Inspection Report Is there trash/debris accumulation in or around the inlet? X More leaf litter than other inlets,some plastic,pollen visible,some woody debris Is the impervious surface compromised in or around the inlet? X Impervious surface is intact Is there an odor in or around the inlet? X No odor observed Describe BMPs in place at the inlet. Coconut fiber filter (ie Metal Zorb filters,booms,filter socks,etc). Storm Drain Inlet#8 Yes N/A No Comments Are fork lift track marks or other staining visible in or around the inlet? X No staining observed Is a sheen,discoloration,or foam visible in the inlet? X None observed Is sediment buildup or dust visible in or around the inlet? X None observed Is there trash/debris accumulation in or around the inlet? X Some wood pieces and some trash Is the impervious surface compromised in or around the inlet? X Impervious surface is intact Is there an odor in or around the inlet? X No odor observed Describe BMPs in place at the inlet. No filters (ie Metal Zorb filters,booms,filter socks,etc). Additional Notes/Observations GN11195 Page 4 of 4 Geosyntec Consultants of NC,P.C.