Loading...
HomeMy WebLinkAboutNCC222952_NOT Closeout Documents_20240401 SEDIMENTATION INSPECTION REPORT (Village of Clemmons) Winston-Salem Field Operations Department Permit#: EN2200202 Erosion Control Division P.O. Box 2511 Date: 3-28-2024 Winston-Salem, NC 27102 Report by: KENT WALL Revised 3-3-22 Phone: 336-462-7481 Project TITAN VILLAGE- SFD CONSTRUCTION Location: 2663 TITAN VILLAGE CT CLEMMONS,NC 1. Pictures: ("x"One)Yes: No: X 2. Potential for NPDES Violation: ("x"One) Yes: No: X Describe: 3. Weather and soil conditions: PT CLOUDY/ MOIST Initial inspection: ("x"One) Yes: No: X 4. Is site currently under notice of violation? ("x"One) Yes: No: X 5. Is the site in compliance with S.P.C.A.and rules? ("x"One) Yes: X No: If no,check violations below: 6. Violations: ("X"all applicable sections) ()--- No approved plan, [UDO Sec.4-7(G);&G.S.113A-57(4)and 15A N.C.A.C4B.0107(c)] ()--- Failure to follow approved plan,[UDO Sec.4-20.1;&G.S.113A-61.1] ()--- Failure to submit revised plan,[UDO Sec.4-18.2;&G.S. 113A-54.1(b)and 15A N.C.A.C.4B.0118(a)] ()--- Failure to provide adequate groundcover,[UDO Sec.4-7(D)(1);&G.S.113A-57(3);&15A N.C.A.C.4B.0007(b)or 15A N.C.A.C. 4B.0124(e)] ()--- Insufficient measures to retain sediment on site, [UDO Sec.4-7(D)(1);&G.S.113A-57(3)] ()--- Failure to take all reasonable measures,[UDO Sec.4-5.2;&15A N.C.A.C.4B0105] ()--- Inadequate buffer zone,[UDO Sec.4-7(A);&G.S.113A-57(1)] ()--- Graded slopes and fills too steep,[UDO Sec.4-7(B);&G.S.113A-57(2)or 15A N.C.A.C.4B.0124(d)] ()--- Unprotected exposed slopes,[UDO Sec.4-7(D)(2);&G.S.113A-57(2)] ()--- Failure to install and maintain erosion control measures,[UDO Sec.4-13;& 15A N.C.A.C.4B.0113] ()--- Failure to keep current self-inspection records,[G.S.113A-54.1&15A NCAC 04B.0131] ()--- Other(describe): 7. Contact made with(name): NEUL IJLDRTCK Title DR HORTON 8. Contact Method: phone#(X) email(X) fax#() letter() person() 9. Corrective actions needed: NO CORRECTIVE ACTIONS. 10. Comments:()No devices in place()Additional devices needed()Devices need maintenance()Devices in&functioning ()No seeding noted()Partially seeded(X)Areas seeded(NO)Off-site sedimentation(YES)Project in compliance THIS PROJECT HAS BEEN COMPLETED AND IS STABLE. THE GRADING PERMIT#EN2200202 HAS BEEN FINALED.YOU WILL NOW NEED TO TERMINATE THE NCGO1 PERMIT COVERAGE. PLEASE GO TO THE FOLLOWING WEB ADDRESS TO APPLY: https://edocs.deq.nc.gov/Forms/NCG01-Termination. AND USE THIS INSPECTION REPORT FOR SUPPORTING DOCUMENTATION. 11. Others present: Office use only: Cityworks (X) Final () [white notebook] Excel () Financially responsible contact ()