Loading...
HomeMy WebLinkAboutNCS000598_Renewal application_20240327 A119al an Air Uquide company March 22,2024 �ZOZ L d�hf State of North Carolina Department of Environmental Quality 0 3 A(3 a 3 8 Energy, Mineral and Land Resources 1612 Mail Service Center, Raleigh,NC 27699-1612 Attention: Brianna Young Subject: NPDES Permit Stormwater Permit No.NCS000598 Renewal Application Airgas USA, LLC—Mebane Facility Mebane,Alamance County,North Carolina Dear Ms. Young: Airgas USA, LLC (Airgas) is submitting the enclosed application for the individual National Pollutant Discharge Elimination System (NPDES) Stormwater Permit No. NCS000598 Renewal. The Permit renewal application package includes: 1. One(1)copy of completed and signed EPA Form I with a topographic map; 2. One(1)copy of completed and signed EPA Form 2F with a site drainage map;and 3. Two (2) copies of the Supplemental Information Required for Renewal of Individual NPDES Stormwater Permit The NPDES Stormwater Permit No. NCS000598 expires on September 30, 2024 and the Permit renewal application needs to be submitted 180 days prior to the Permit expiration date. Thus, Airgas meets the required permit renewal application deadline. As instructed, an electronic copy of the permit application package is also emailed to your attention at btianna.young@ncdenr.gov. Please be advised that Airgas had planned to collect a sample from Outfall 001 for analyses of the pollutants listed in Table A of EPA Form 2F prior to the submission of the Permit renewal application. However,the planned sampling and analysis did not occur at the time of the application preparation and Airgas is reporting the 2023 compliance sampling data in Table A of EPA Form 2F. BOD5 is one of the pollutants listed in Table A of EPA Form 2F but not listed in the current Permit and therefore it was not analyzed in 2023. Due to the nature of the Nitrogen, Oxygen and Argon production operations at the facility, BOD5 is unlikely detected or even if it is detected, it may be present in a very low concentration. If you need additional information and/or have any questions about the renewal application, please contact Mr. Stephen Kim, our consultant, at(215)941-2770 or genesisenvironmental@comcast.net or me at(330)454-1330 or rodney..st.john @air aQ s.com. Sincerel , Rodney John Plant Manager cc: File Enclosures: As Noted EPA FORM'1 EPA Identification Number NPDES Permit Number Facility Name OMB No.2040-0004 N/A NCS000598 Airgas USA LLC Expires 077311202E Form U.S.Environmental Protection Agency 1 \-.EPA Application for NPDES Permit to Discharge Wastewater NPDES GENERAL INFORMATION REQUIRINGSECTION 1.ACTIVITIES •D r AND 1.1 Applicants Not Required to Submit Form 1 1.1.1 Is the facility a new or existing publicly owned 1.1.2 Is the facility a sludge-only facility(i.e.,a facility treatment works or has your permitting authority directed you to submit Form 2A? that does not discharge wastewater to surface waters)? If yes,STOP.Do NOT complete No If yes,STOP.Do NOT complete [a No Form 1.Complete Form 2A.If the Form 1.Complete Form 2S. facility is also a treatment works treating domestic sewage,you must also complete Form 2S. 1.2 Applicants Required to Submit Form I € 1.2.1 Is the facility a concentrated animal feeding 1.2.2 Is the facility an existing manufacturing, CL operation or a concentrated aquatic animal commercial,mining,or silvicultural facility that is a production facility? currently discharging process wastewater? z Yes 4 Complete Form 1 and 0 No ❑ Yes 4 Complete Form Ej No Form 2B. 1 and Form 2C. 1.2.3 Is the facility a new manufacturing,commercial, 1.2.4 Is the facility a new or existing manufacturing, mining,or silvicultural facility that has not yet commercial,mining,or silvicultural facility that commenced to discharge? discharges only nonprocess wastewater? Yes 4 Complete Form 1 and E] No ❑ Yes 4 Complete Form 1 0 No Form 2D. and Form 2E. a1.2.5 Is the facility a new or existing facility whose 1.2.6 Is the facility a new or existing treatment works discharge is composed entirely of stormwater treating domestic sewage that discharges associated with industrial activity or whose wastewater to surface waters? discharge is composed of both stormwater and non. stormwater? 0 Yes 4 Complete Form 1 and ❑ No ❑ Yes 4 Complete Form 1, ✓� No Form 2F unless Form 2S,and exempted by 40 CFR any other 122,26(b)(14)(x)or applicable forms, (b)(15). as directed by your permitting authorii . SECTIONDD• • • i 2_1 Facility Name 0 Airgas USA LLC 2.2 EPA Identification Number -a M N/A N 2_3 Facility Contact a Name(first and last) Title Phone number Rodney St.John Plant Manager_ g (919)304-1010 Email address 4 E b z Rodney.st.john@airgas.com EPA Form 3510-1 Page 1 EPA Identification Number NPDES Permit Number Facility Name OMB No.2040-0004 N/A NC5000598 Airgas USA LLC Expires 07131/2026 224 Facility Mailing Address Street or P.O.box 2025 Development Center Drive City or town State ZIP code Mebane NC 27302 2_5 Facility Location Street,route number,or other specific identifier b C v 2025 Development Center Drive rn .2 County name County code(if known) u Alamance 0 E _j City or town State ZIP code Z 'c° 1 1 Mebane INC 127302 CODESSECTION 3.SIC AND NAICS r 3 1 SIC Code(s) Description(optional) 2813 Industrial gases manufacturing-Nitrogen,Oxygen and Argon N N 78 U z 3.22 NAICS Code(s) Description(optional) iO v 325120 Industrial gases manufacturing Nitrogen,Oxygen and Argon SECTION 4.OPERATOR INFORMATION(40 4_1 Dame of Operator Airgas USA LLC c 0 4.2 Is the name you listed in Item 4.1 also the owner? R w 121 Yes ❑ No 7. 4.3 Operator Status o — 2 ❑ Public—federal ❑ Public—state ❑ Other public(specify) d o © Private ❑ Other(specify) 444 Phone Number of Operator (919)304-1010 EPA Form 3510-1 Page 2 EPA Identification Number NPDES Permit Number Facility Name OMB No.2040-0004 N/A NC5000598 Airgas USA LLC Expires 0713112026 4_5 Operator Address o Street or P.O.Box 3 2025 Development Center Drive City or town State ZIP code 4� U 12 Mebane NC �27302 C address of operator [Email odney.st.john@airgas.com 1 1 5-1 Is the facility located on Indian Land? ❑Yes ❑✓ No ENVIRONMENTALSECTION 6.EXISTING i 6.1 Existing Environmental Permits(check all that apply and print or type the corresponding permit number for each) a ® NPDES(discharges to ❑ RCRA(hazardous wastes) ❑ UIC(underground injection of a H surface water) fluids) NCS000598 ❑ PSD(air emissions) ❑ Nonattainment program(CAA) ❑ NESHAPs(CAA) �Dff=cean mping(MPRSA) ❑ Dredge or fill(CWA Section 404) ❑ Other(specify) 71 Have you attached a topographic map containing all required information to this application?(See instructions for specific requirements.) ✓❑ Yes ❑ CAFO—Not Applicable(See requirements in Form 2B.) SECTIONr 81 Describe the nature of your business, Airgas USA LLC(Airgas)separates the atomospheric air,produces liguid Nitrogen,liquid Oxygen and liquid y Argon(SIC 2813),and distribute products to its customers in the region via tank trucks. Airgas has .N truck maintenance operations inside a maintenance shop at the site location. m a z SECTION •• r 91 Does your facility use cooling water? ❑ Yes ❑✓ No 4 SKIP to Item 10.1. 99.22 Identify the source of cooling water.(Note that facilities that use a cooling water intake structure as described at M 2 40 CFR 125,Subparts I and J may have additional application requirements at 40 CFR 122.21(r).Consult with your a NPDES permitting authority to determine what specific information needs to be submitted and when.) o m V c EPA Form 3510-1 Page 3 EPA idenbfication Number NPDES Permit Number Facility Name OMB No.2040-0004 N/A NCS000598 Airgas USA LLC Expires 0713112026 SECTIONI VARIANCE REQUESTS # I Q.1 Do you intend to request or renew one or more of the variances authorized at 40 CFR 122.21(m)?(Check all that w apply.Consult with your NPDES permitting authority to determine what information needs to be submitted and when.) ❑ Fundamentally different factors(CWA ❑ Water quality related effluent limitations(CWA Section Cr Section 301(n)) 302(b)(2)) ❑ Non-conventional pollutants(CWA ❑ Thermal discharges (CWA Section 316(a)) Section 301(c)and(g)) ❑✓ Not applicable SECTION • CERTIFICATION STATEMENT(40 11.1 In Column 1 below, mark the sections of Form 1 that you have completed and are submitting with your application. For each section,specify in Column 2 any attachments that you are enclosing to alert the permitting authority. Note that not all applicants are required to provide attachments. Column 1 Column 2 0 Section 1:Activities Requiring an NPDES ❑ w/attachments Permit ❑ Section 2: Name, Mailing Address,and ❑ w/attachments Location ✓❑ Section 3:SIC Codes ❑ wl attachments ❑ Section 4:Operator Information ❑ w/attachments Section 5: Indian Land ❑ w/attachments Section 6: Existing Environmental Permits ❑ wl attachments ❑ wl additional 0 Section 7: Map 0 w/topographic map attachments a ✓❑ Section 8:Nature of Business ❑ w/attachments :~ ✓❑ Section 9:Cooling Water Intake Structures ❑ wl attachments 0 Section 10.:Variance Requests ❑ wl attachments 0 Section 11:Checklist and Certification ❑ wl attachments y Statement 1?.2 Provide the following certification.(See instructions to determine the appropriate person to sign the application.) ca Certification Statement I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system,or those persons directly responsible for gathering the information,the information submitted is, to the best of my knowledge and belief,true, accurate,and complete. I am aware that there are significant penalties for submitting false information,including the possibility of fine and imprisonment for knowing violations. Name(print or type first and last name) Official title Thomas Stringer Vice President,Production&Project Execution Signature Date signed r 3�Zo�y�x y EPA Form 3510-1 Page 4 ATTACHMENT TO EPA FORM 4 TOPOGRAPHIC MAP (USGS MAP Mebane Quadrangle, North Carolina,7.5 Minute Series) -a• CANTERWOOO OR •._ , ..,, y � 1V[aNtER 9T . l�irgas`Site Locafion Outfall001 0 _ � o DIP Olt n 4 � o w Y sr ff 5 cxo )RA Sr EXO �sr sf N O i ;/ a .$i S Fly ST o O 4 S �bSUa F~ SCALE 1:24 OW 1 0.5 0 KILOMEfER5 1 2 1000 500 0 YETERS 1000 2000 1 0.5 0 1 MILES 1000 0 1000 2000 3000 4000 5111A buuc M0 am 9000 10000 FCC-" Source: Figure 1 TOPOGRAPHIC MAP USGS Topo Map—Mebane Airgas USA, LLC Quadrangle, NC 2022 2026 Development Center Drive, Mebane, NC 27302 ERA FORM 2F EPA Identification Number NPDES Permit Number Facility Name OMB No.2040-0004 N/A NC5000598 Airgas USA LLC Expires 0713112026 Form U.S Environmental Protection Agency 2F V,EPA Application for NPDES Permit to Discharge Wastewater NPDES STORMWATER DISCHARGES ASSOCIATED WITH INDUSTRIAL_ACTIVITY SECTION • r 1 1.1 Provide information on each of the facilit 's outfalls in the table below Outfall Receiving Water Name Latitude Longitude Number 001 Tributary(Tinnis Creek) 36 Deg 5' 30.36" 79 Deg 17` 57.42" c 0 *'a to Moadams Creek u 0 J ep 7 0 SECTION '• 1 21 Are you presently required by any federal,state,or local authority to meet an implementation schedule for constructing,upgrading,or operating wastewater treatment equipment or practices or any other environmental programs that could affect the discharges described in this application? ❑ Yes ❑✓ No 4 SKIP to Section 3. 2_2 Briefly identify each applicable project in the table below. Final Compliance Brief Identification and Affected Outfaits Source(s)of Discharge Dates Description of Project (list outfall numbers) Required Projected c d E 0 C a E 22.33 Have you attached sheets describing any additional water pollution control programs(or other environmental projects that may affect your discharges)that you now have underway or planned?(optional item) ❑ Yes ❑ No EPA Form 3510.21' Page 1 EPA Idenfficalion Number NPDES Permit Number Facility Name OMB No.2040-0004 N/A NCS000598 Airgas USA LLC Expires 0713112026 SECTION 3.SITE D' 1 31 Have you attached a site drainage map containing all required information to this application?(See instructions for Im A to c ra specific guidance.) r 'T M n ❑✓ Yes SECTION 4. •O i Provide information on the facility's pollutant sources in the table below. Outfall Impervious Surface Area Total Surface Area Drained Number (within a mile radius of the facility) (within a mile radius of the facility) specify units specify units 001 4.11 6.07 acres acres specify units specify units specify units specify units specify units specify units specify units specify units specify units specify units 4.2 Provide a narrative description of the facility's significant material in the space below.(See instructions for content requirements.) w The site is an air separation unit(ASU)plant.The raw material is the atmospheric air and the final products are liquid nitrogen,liquid oxygen and liquid argon. The final products are stored in the cryogenic tanks a outdoors.Loading activities takes place in the truck loading scale area and the stormwater runoff from the truck y loading area is collected and discharged into the public sewer system. Trash is collected in a trash dumpster with lid c a and is hauled away periodically by a licensed hauler. Trucks are maintained inside the truck maintenance shop. o Diesel Fuel Exhaust(DEF)is stored outdoors and added to transport trucks. Herbicides are used for weed control once or twice a year and applied by a contracted third party. 43 Provide the location and a description of existing structural and non-structural control measures to reduce pollutants in stormwater runoff, See instructions forspecificguidance.) Stormwater Treatment Codes Outfall from Number Control Measures and Treatment Exhibit 2F-1 lisle 001 Sedimentation(Settling)-(Onsite)Wet Pond 1-U 001 Discharge to Surface Water 4-A EPA Form 3510-2F Page 2 EPA Identification Number NPDES Permit Number Facility Name OMB No.200-0004 N/A NCS000598 Airgas USA LLC Expires 0713112026 SECTION •N STORMWATER 1 I 5 Provide the following certification.(See instructions to determine the appropriate person to sign the application.) I certify under penalty of law that the outfall(s) covered by this application have been tested or evaluated for the presence of non-stormwater discharges. Moreover, I certify that the outfalls identified as having non-stormwater discharges are described in either an accompanying NPDES Form 2C, 2D, or 2E application. Name(print or type first and last name) Official title Thomas Stringer Vice President, Production&Project Execution Signature Date signed w Er G —2 Provide the testing information requested in the table below. Onsite Drainage Points o Outfall Description of Testing Method Used Date(s)of Testing Directly Observed {Number Dudng Test m 3 001 Review of the facility's design and 02/13/2024 Drainage inlet cis c observations of facility operations during a dry period to the onsite wet pond SECTION . SIGNIFICANT LEAKS OR 1 Q 6—� Describe any significant leaks or spills of toxic or hazardous pollutants in the last three years. Cn None 0 co Y d J C LTJ SECTIONDISCHARGE • ' • I See the instructions to determine the pollutants and parameters you are required to monitor and, in turn,the tables you must complete.Not all applicants need to complete each table. 7_1 Is this a new source or new discharge? Yes 4 See instructions regarding submission of � No 4 See instructions regarding submission of estimated data. actual data. Tables A,B,C,and D cc T�2 Have you completed Table A for each outfall? 0 Yes EPA Form 3510-2F Page 3 EPA Identification Number NPDES Permit Number Facility Name OMB No.2040-0004 N/A NCS000598 Airgas USA LLC Expires 0713112026 73 Is the facility subject to an effluent limitation guideline(ELG)or effluent limitations in an NPDES permit for its process wastewater? ❑ Yes No 4 SKIP to Item 7.5. 7_4 Have you completed Table 6 by providing quantitative data for those pollutants that are(1)limited either directly or indirectly in an ELG and/or(2)subject to effluent limitations in an NPDES permit for the facility's process wastewater? ❑ Yes 7. Do you know or have reason to believe any pollutants in Exhibit 2F-2 are present in the discharge? ❑ Yes ❑✓ No 4 SKIP to Item 7,7. 7_6 Have you listed all pollutants in Exhibit 2F-2 that you know or have reason to believe are present in the discharge and provided quantitative data or an explanation for those pollutants in Table C? ❑ Yes 7_7 Do you qualify for a small business exemption under the criteria specified in the Instructions? ❑ Yes-SKIP to Item 7.18. ❑ No d 7_8 Do you know or have reason to believe any pollutants in Exhibit 2F-3 are present in the discharge? ❑ Yes ❑ No 4 SKIP to Item 7,10. 0 0 7_9 Have you listed all pollutants in Exhibit 2F-3 that you know or have reason to believe are present in the discharge in Table C? 0 ❑ Yes C m a' 710 Do you expect any of the pollutants in Exhibit 2F-3 to be discharged in concentrations of 10 ppb or greater? L U o ❑ Yes ❑ No 4 SKIP to Item 7.12. 7.11 Have you provided quantitative data in Table C for those pollutants in Exhibit 2F-3 that you expect to be discharged in concentrations of 10 ppb or greater? ❑ Yes 7.12 Do you expect acrolein,acrylonitrile,2,4-dinitrophenol,or 2-methyl4,6-dinitrophenol to be discharged in concentrations of 100 ppb or greater? ❑ Yes ❑✓ No 4 SKIP to item 7.14, 713 Have you provided quantitative data in Table C for the pollutants identified in Item 7.12 that you expect to be discharged in concentrations of 100 ppb or greater? ❑ Yes 7.14 Have you provided quantitative data or an explanation in Table C for pollutants you expect to be present in the discharge at concentrations less than 10 ppb(or less than 100 ppb for the pollutants identified in Item 7.12)? ❑ Yes 7.15 Do you know or have reason to believe any pollutants in Exhibit 2F-4 are present in the discharge? ❑ Yes © No 4 SKIP to Item 7,17. EPA Form 3510-2F Page 4 EPA Idenffication Number NPOES Permit Number Facility Name OMB No,2040-0004 N/A NCS000598 Airgas USA LLC Expires 07131/2026 7.16 Have you listed pollutants in Exhibit 217-41 that you know or believe to be present in the discharge and provided an explanation in Table C? ❑ Yes a 7.17 Have you provided information for the storm event(s)sampled in Table D? ❑� Yes U `0 Used or Manufactured Toxics 7.18 Is any pollutant listed on Exhibits 2F-2 through 2F-4 a substance or a component of a substance used or ,o manufactured as an intermediate or final product or byproduct? c ❑ Yes ❑✓ No 4 SKIP to Section 8, L 7.19 List the pollutants below,including TCDD if applicable.Attach additional sheets,if necessary. v, �. 4. 7. 2, 5. 8. 3, 6. 9. SECTIONBIOLOGICAL TOXICITYi 60 Do you have any knowledge or reason to believe that any biological test for acute or chronic toxicity has been made R on any of your discharges or on a receiving water in relation to your discharge within the last three years? 0 c' ❑ Yes ❑✓ No 3 SKIP to Section 9, B_2 Identify the tests and their purposes below. Test(s) Purpose of Test(s) Submitted to NPDESPermittin Authority? Date Submitted 0 ❑ Yes ❑ No ❑ Yes ❑ No 0 m ❑ Yes ❑ No SECTION9.CONTRACT •- • r 9_1 Were any of the analyses reported in Section 7(in Tables A through C)performed by a contract laboratory or consulting firm? ED Yes ❑ No 4 SKIP to Section 10. 0 92 Provide information for each contract laboratory or consulting firm below. Laboratory Number 1 Laboratory Number 2 Laboratory Number 3 Dame of laboratory/firm pace Analytical Services,LLC Hl .y Z. Laboratory address 6701 Conference Drive, Raleigh,NC 27607 b Phone number 0 U (919)834-4984 Pollutant(s)analyzed O&G,COD,TSS,Total Phosphorus,TKN, Total Nitrogen and pH EPA Foam 3510-2F Page 5 EPA Identification Number NPDES Permil Number Facilily Name OMB No.2040-0004 N/A NCS000598 Airgas USA LLC Expires 0713112026 SECTION 1 CHECKLIST AND 1 AND 10.1 In Column 1 below,mark the sections of Form 2F that you have completed and are submitting with your application. For each section,specify in Column 2 any attachments that you are enclosing to alert the permitting authority. Note that not all applicants are required to complete all sections or provide attachments. Column 1 Column 2 ❑� Section 1 ❑ wl attachments(e.g., responses for additional outfalls) ❑✓ Section 2 ❑ w/attachments Section 3 0 w/site drainage map ❑� Section 4 ❑ wl attachments ❑� Section 5 ❑ wl attachments ❑✓ Section 6 ❑ wl attachments ❑✓ Section 7 ❑ Fable A ❑ wl small business exemption request -` ❑ Table B ❑ wl analytical results as an attachment C ❑ Table C ❑ Table D V d 0 Section 8 ❑ w/attachments ca ✓❑ Section 9 ❑ wl attachments(e.g., responses for additional contact laboratories or firms) U ❑✓ Section 10 w c �0 2 Provide the following certification,(See instructions to determine the appropriate person to sign the application.) Certification Statement I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel property gather and evaluate the information submitted.Based on my inquiry of the person or persons who manage the system or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. l am aware that there are significant penalties for submitting false information,including the possibility of fine and imprisonment for knowing violations. Name(print or type first and last name) Official title Thomas Stringer Vice President,Production&Project Execution Signature Date signed EPA Form 3510-2F Page 6 EPA Identification Number NPDES Permit Number Facility Name Outfall Number OMB No.2040-0004 N/A I NCS000598 Airgas USA LLC col Expires 07/3112026 TABLE A.CONVENTIONAL AND NON CONVENTIONAL PARAMETERS(40 You must provide the results of at least one anal1 sis for every polkitant in this table.Complete one table for each ouffaT.See instructions for additional details and requirements. MaXltnafn�DaliyaDischarge Average "MON 618 ar'g ape 100 Atimur of Stbiw der A Iv "Sam ed 0" Mo.-- Eta!' codbs 166 Instruc*O: Ig �dlwh -00 Oil and grease <4.9 n <4.9 mg/I 2 Biochemical oxygen demand(BOD5) Not measured N/A Not measured N/A 0 Chemical oxygen demand(COD) <25 mg/I N/A <25 mg/I N/A 2 A Total suspended solids(TSS) 17.4 mg/I N/A 15.8 mg/I N/A 2 S..:,. Total phosphorus 0.061 mg/I N/A <0.056 mg/I N/A 2 IS. Total Kjeldahl nitrogen(TKN) 0.88 mg/I N/A <0.565 mg/I N/A 2 7.1' Total nitrogen(as N) 2.00 mg/I N/A <0.6745 mg/I N/A 2 pH(minimum) 6.1 s.u. N/A I 8. pH(maximum) 6.6 sm. N/A Sampling shall be conducted according to sufficiently sensitive test procedures(i.e.,methods)approved under 40 CFR 136 for the analysis of pollutants or pollutant parameters or required under 40 CFR Chapter 1,Subchapter N or 0.See instructions and 40 CFR 122.21(e)(3). EPA Form 3510-2F Page 7 This page.intentionally left blank. EPA IdenVication Number NPDES Permit Number Facility Name Outfall Number OMB No.2040-0004 N/A NCS000598 Airgas USA LLC 001 Expires 07/31/2026 TABLE B.CERTAIN CONVENTIONAL AND NON CONVENTIONAL '• 1 CFR 122.26(C)(1)(1)(E)(4) t List each pollutant that is limited in an effluent limitation guideline(ELG)that the facility is subject to or any pollutant listed in the facility's NPDES permit for its process wastewater(if the facility is operating under an existing NPDES permit).Complete one table for each cuNall.See the instructions for additional details and requirements. �fn YYyy - axiMa" al{y f3isahairg a Dslliy, ischarge Source of P61tiartt grid CAS Ntnntier' u Niumberrdf 5tonm Mormation Grab$ftle7aken :. Giab Sarh le TaTcetlr (newsu�ucdsaw (if avaUabte). Flow4i(feighbed _ p FIiWdlgltted Et/ents Sampled Dtidrtg�i1 dudn]Fiist C discfiaigers ardy;use!> omposite Eoritt�otdte 30 Mlnukss .301Mlmites codes'in mshucBons)" Not applicable Sampling shall be conducted according to sufficiently sensitive test procedures(i.e.,methods)approved under 40 CFR 136 for the analysis of pollutants or pollutant parameters or required under 40 CFR Chapter I,Subchapter N or 0.See instructions and 40 CFR 122.21(e)(3). EPA Form 3510-2F Page 9 This page intentionally,left blank. EPA Identification Number NPOES Permit Number Facility Name Outfall Number OMB No.2040-0004 N/A NCSOCO598 Airgas USA LLC 001 Expires 0713112026 TABLE C.TOXIC POLLUTANTS,CERTAIN HAZARDOUS SUBSTANCES,AND ASBESTOS(40 CFR 122.26(C)(1)(1)(E)(4)AND 40 CIFIR 122.21(G)(7)(VI)(B)AND(VII))i List each pollutant shown in Exhibits 2F-2,2F-3,and 2F4 that you know or have reason to believe is present.Complete one table for each outfall.See the instructions for additional details and requirements. Maximum Daily Discharge Average Daily Discharge Source of (Spec' units s eci units Information Pollutant and CAS Number Number of Storm Grab Sample Taken Grab Sample Taken (new sourceinew (if available) During First Flow-Weighted During First Flow-Weighted Events Sampled dischargers only;use 30 Minutes Composite 30 Minutes Composite codes in instructions) Not applicable Sampling shall be conducted according to sufficiently sensitive test procedures(i.e.,methods)approved under 40 CFR 136 for the analysis of pollutants or pollutant parameters or required under 40 CFR Chapter I,Subchapter N or 0.See instructions and 40 CFR 122.21(e)(3), EPA Form 3510-2F Page 11 This page intentionally left blank. EPA Identification Number NPDES Permit Number Facility name Outfall Number OMB No.2040-0004 N/A NCS000598 Airgas USA LLC 001 Expires 07/31/2026 STORMTABLE D. a- • r Provide data for the storm event(s)that resulted in the maximum daily discharges for the flow-weighted composite sample. Number of Hours Between Total Rainfall During Maximum Flow Rate Duration of Storm Event (in inches} Beginning of Storm Measured and Total Flow from Rain Event Date of Storm Event (in hours) Storm Event End of Previous Measurable Rain During Rain Event (in gallons or specify units) (in gpm or specify units) Event 12/17/7023 App.15.3 hours 2.75 App. 148 hours Not estimated App.349,377 gallons Provide a description of the method of flow measurement or estimate. It rained on 12/17/2023 but the sampling was conducted on 12/18/2023. Stormwater runoff from the industrial activity areas at the facility is collected in the onsite wet pond with the design total capacity of approximately 112,270 ft3. Due to the design,the stormwater discharge occurs at Outfall 001(the wet pond 18"HDPE outlet/effluent pipe)when the water level in the wet pond reaches the drawdown orifice of the riser structure. This drawdown orifice is approximately 9 feet above the bottom of the wet pond. Due to the retention volume of the wet pond,often there is not a discharge from the wet pond even if a qualified storm event occurs. Part of the wet pond function is a slow release of the stormwater runoff collected from the site. It rained on December 17,2023 and the rainfall was approximately 2.75 inches. During this rain event,the amount of runoff from the drainage area into the onsite wet pond is approximately 46,708 ft3(equivalent to 349,377 gallons). The new stormwater discharge runoff was combined with the stormwater already present in the wet pond. Some of the stormwater collected in the wet pond was discharged via the drawdown orifice of the riser structure and the wet pond 18"HDPE outlet/effluent pipe(Outfall 001). There is not a flow measurement device in the wet pond overflow structure nor at the outfall, Thus the actual discharge rate was not measured nor able to be estimated. EPA Farm 3510-2F Paae 13 ATTACHMENT TO EPA FORM 2F SITE DRAINAGE MAP •�"� ' � .,.-_ - - —�"``i', � yeot�a--owc-1-1= I may'^ ce:Kwr--rr re_I�;a,l r — � I OUTFAI�001 NOTES: Outfa11001: Lat: 360 5'30.36„ 1i3 ,,,,. Long: 7901 T 57.42" • � I I I 1 Drainage area for Outfall 001:6.07 acres Ar ��,gym.nr.ac ec.�M - ►: � r'- �. Source : Figure 2 SITE DRAINAGE MAP Site Construction Grading &Drainage Plan : C.60098-DWG-1-1-0004 Airgas USA, LLC 2025 Development Center Drive, Mebane, NC 27302 SUPPLEMENTAL INFORMATION REQUIRED FOR RENEWAL OF INDIVIDUAL NPDES STORMWATER PERMIT SUPPLEMENTAL INFORMATION REQUIRED FOR RENEWAL OF INDIVIDUAL NPDES STORMWATER PERMIT Two copies of each of the following shall accompany this submittal in order for the application to be considered complete: (Do not submit the site Stormwater Pollution Prevention Plan) Initials TS 1. A current Site Map from the Stormwater Pollution Prevention Plan. The location of industrial activities(including storage of materials,disposal areas,process areas and loading and unloading areas),drainage structures,drainage areas for each outfall, building locations and impervious surfaces should be clearly noted. TS 2. A summary of Analytical Monitoring results during the term of the existing permit (if your permit required analytical sampling). Do not submit individual lab reports. The summary can consist of a table including such items as outfall number, parameters sampled,lab results, date sampled,and storm event data. TS 3. A summary of the Visual Monitoring results. Do not submit individual monitoring reports.The summary can consist of a table including such items as outfall number, parameters surveyed,observations,and date monitoring conducted. TS 4. A summary of the Best Management Practices utilized at the permitted facility. Summary should consist of a short narrative description of each BMP's in place at the facility. If the implementation of any BMP's is planned,please include information on these BMP's. TS 5. A short narrative describing any significant changes in industrial activities at the permitted facility. Significant changes could include the addition or deletion of work processes,changes in material handling practices,changes in material storage practices,and/or changes in the raw materials used by the facility. TS 6. Certification of the development and implementation of a Stormwater Pollution Prevention Plan for the permitted facility(Sign and return attached form). If the final year analytical monitoring of the existing permit term has not been completed prior to filing the renewal submittal,then the last years monitoring results should be submitted within 30 days of receipt of the laboratory reports. (i.e. do not withhold renewal submittal waiting on lab results) SUPPLEMENTAL INFORMATION REQUIRED FOR RENEWAL OF INDIVIDUAL NPDES STORMWATER PERMIT(No. NCS000598) Airgas USA LLC-Mebane ASU 2025 Development Center Drive Mebane, Alamance County, NC 27302 1. Current Site Map from the Stormwater Pollution Prevention Plan See attached. 2. A Summary of Analytical Monitoring Results during the Term of the Existing Permit Airgas USA LLC -Mebane ASU was under the final phase of the construction when the current NPDES Permit (No.NCS000598)was issued in September 2019. The NPDES Permit requires that the analytical monitoring be conducted semi-annually during Period 1 from January 1 through June 30 and during Period 2 from July 1 through December 31 and that the first analytical monitoring period begin from Period 1 in 2020. There is one stormwater discharge outfall designated as Outfall 001 at the facility. The available analytical monitoring results during the current permit period are summarized below. Parameters( Anal tical�viomtarin )Zesults at Outfall R01 Disc WW Benchmark 2020 2022, - 2023 Charaetertics Values - Penod 2 Penod 1 Period 2 Peio 1 Period 2 ,.. . - (11/12/20 :0) (3IQ9/2022 (].Q/OI/2022} (6/23/2023� (12/18/202.. Oil&Grease 15mg/I <5.0m 1 <15m <15mg/I <4.9m 1 <4.9mg/I COD 120 mg/l <25 mg/1 26.2 mg/I <25 mg/I <25 mg/I <25 mg/l TSS 100 m 1 18.9m 1 66.5m 1 9.5m 1 17.4m 14.2m 1 Total N/A <0.05 mg/1 0.14 mg/l 0.06 mg/l <0.05 mg/I 0.061 mg/I Phosphorus Total Nitrogen N/A <0.52 mg/I 0.73 mg/1 0.41 mg/1 1.00 mg/1 <0.349 mg/I H 6-9 s.u. 6.6 s.u. 7.1 s.u. 7.3 s.u. 6.6 m 6.1 s.u. Total Rainfall - 3.3 inches 2.4 inches 2.5 inches 2.5 inches 2.75 inches New Motor Oil -- <55 gallons <55 gallons <55 gallons <55 gallons <55 gallons Usage It is noted that there were certain periods (Period 1 in 2020 and Periods 1 and 2 in 2021) when the analytical monitoring was not able to be conducted during the current permit period. Although the startup of the facility occurred in February 2020, the site continued to be under the final phase of construction and the stormwater discharge from the site continued to be under the construction permit for a period due to the ongoing construction activities including those in the wet pond. The final inspection under the NPDES Permit for Construction Activities was conducted in early June 2020 and the final inspection report that served as the Notice of Termination (NOT) of the NPDES Permit for Construction Activities was issued on June 5, 2020. Thus, the facility was not able to begin conducting the actual stormwater sampling under the current NPDES Permit during Period 1 in 2020 but it began from Period 2 in 2020. Page 1 of 4 Stormwater runoff from the industrial activity areas at the facility is collected in the onsite wet pond with the design capacity of approximately 112,270 ft3. Due to the design, the stormwater discharge occurs at Outfall 001 (the wet pond 18" HDPE outlet/effluent pipe) when the water level in the wet pond reaches the drawdown orifice of the riser structure. This drawdown orifice is 9 feet above the bottom of the wet pond. Due to the retention volume of the wet pond,often there is not a discharge from the wet pond even if a qualified storm event occurs. In addition, it was discovered that during a good portion of 2021, the riser structure in the wet pond leaked and Airgas investigated and corrected the identified leakage issue. For this reason,the analytical monitoring was not conducted during Periods 1 and 2 in 2021. It is noted that the analytical monitoring required in 2024 has not been conducted at the time of the NPDES Permit renewal application preparation. In accordance with the available analytical monitoring results above,the stormwater disdischarge did not exceed the benchmark values. 3. A Summary of Visual (Qualitative) Monitoring Results The NPDES Permit requires that the visual monitoring be conducted semi-annually during Period 1 from January 1 through June 30 and during Period 2 from July 1 through December 31. As discussed in Section 2 above, due to the construction completion progress in 2020 and due to the design and leakage issue of the onsite wet pond,there were not discharges during Period 1 in 2020 and during Periods 1 and 2 in 2021 during the current NPDES Permit period. The available visual monitoring results are summarized below. Visual:IvIonitorin :Rest-its at Qdtfa11..001.: . Discharge Characteristics 2020 2022 2022 2, 23 2023 Period'2 Pefiod l Reriod 2'` Period 1 Pezxod2 - = - 11X1212020 3109j2022 1OX01/2022 6/23%20.23; � X2/18/2023 Color Clear Clear Clear Clear Clear Odor None None None None None Clarity Clear Clear Clear Clear Clear Floating Solids Absent Absent Absent Absent Absent Suspended Solids Absent Absent Absent Absent Absent Foam Absent Absent Absent Absent Absent Oil Sheen None None None None None Erosion or deposition at the None None None None None outfall Other obvious indicators of None None None None None stormwater pollution It is noted that the visual monitoring required in 2024 has not been conducted at the time of the NPDES Permit renewal application preparation. In accordance with the visual monitoring results above, no issues are identified and it is determined that the SWPPP is effective as written and no additional control measures/best management practices are needed. Page 2 of 4 4. A Summary of Best Management Practices Stormwater Control Measures (SCMs) and structural and non-structural Best Management Practices (BMPs)employed at the facility are identified in the SWPPP and presented below. Structural and Noz1 Descnptton o Activities Wet pond • All stormwater runoff associated with industrial activities at the facility is collected in the wet pond. • The wet pond effluent is discharged into the nearby receiving water in a controlled manner. a The runoff flow and certain pollutants associated with settleable articles are controlled. Secondary containment • Oil-filled equipment subject to SPCC rules are provided with secondary containment; • Oil storage tanks are provided with secondary containment; • Water treatment chemical storage containers are provided with secondary containment;and • All oil drums are placed on the secondary containment pallets. • The rain water collected in a dike for the transformer is checked and released only when no oil sheen is observed. • DEF storage container is a double-walled tank and is provided with the "gun"operations with a drip pan. • DEF drips received in the drip pan are collected in a separate container for offsite disposal or for reuse. Minimize exposure • All compressors with the oil reservoirs are located in the compressor building. a All oil drums are stored indoors. • All chemicals are stored inside buildings or shelter. • Truck maintenance activities take place indoors in the maintenance shop. • Dum ster cover remains closed when not in use. Good housekeeping • All tanks are properly labeled; • Locate tanks away from areas of heavy traffic; • Maintain up-to-date material inventory; a Arrange for regular trash pickup; • Train staff in basic cleanup procedures;and • Encourage proper material storage techniques. Preventive maintenance • Quarterly inspection of all structures,storage tanks,catch basins,and equipment;and • Proper upkeep of tanks,piping and equipment Spill prevention and • Maintain spill response kits for each plant and restock as necessary,as response specified in the facility SPCC plan. Visual site inspections • Quarterly facility inspections; and and evaluation • Semi-annual visual observations of discharges Erosion and sediment • Stabilization of the site with gravel,stones or vegetation as needed; controls and • Silt fence,where needed. Page 3 of 4 Note: (1) Additional BMPs related to oil storage are discussed within the facility's Spill Prevention, Control,and Countermeasure(SPCC)Plan. 5. A Short Narrative Describing Any Significant Changes in Industrial Activities Since the completion of the facility construction in 2020,the facility operations largely remained the same during the current NPDES Permit period. The only change is an addition of Diesel Exhaust Fuel (DEF) operations at the facility. A DEF tote is stored outdoors and the transport truck drivers add/pump DEF into the diesel fuel tank in their trucks.Proper SCMs/BMPs are employed for this operation. 6. Certification of the Development and Implementation of a SWPPP See attached. Page 4of4 ATTACHMENTS TO SUPPLEMENTAL INFORMATION REQUIRED FOR RENEWAL OF INDIVIDUAL NPDES STORMWATER PERMIT • Current Site Map(Site Plan)from the Stormwater Pollution Prevention Plan • Stormwater Pollution Prevention Development and Implementation Certification SITE PLAN [Revised November 20221 " — " — . — . — . — . _ . ... —� LEGEND: � • Pond • — App.Property Line I • • - App.Fence Line General Runoff Direction I • Oil Storage 8 Spill Kit I ---- Storm Sewer Line �• Grass ® Storm Sewer Inlet / I Approximate drainage area for Wet Pond — . . — . . — . . — . . — . . . . — . . — . . — . . — . . / Grass I Tinnis Creek / Wet Acce Pond 1 ; Truck Road [ Parking Gravel I Truck Argon tank Outfall 001 e I Lat:36'05'29"N 1 Scal O O Cold Box Long:79'17"57'VV O 0 Grass �J I Cryogenic rGas Tanks t7 f � • � r ; ompressor Bld ■ 0 I' Substation r ■ ©nsfo er +� Coding (owned by Duke ' ❑ Tojver Grass Energy) O O I Gravel ' Car Office/ ;Car . • _ • i Parking Control Rm parking 1 _ _ Car Parking Asphalt Water Treil. Note: • � • � • . ■ Maintenance Sldg 1. Not to scale • Asphalt Shop 2. Total property area:11.68 acres `. DEF Operations 3. Outfall 001 drainage area: App.6.07 acres according to the design 4. Total impervious area:App.4.11 acres,67,71%of the Outfall 001 drainage area ` Access Road 5. Receiving water: Tinnis Creek,a tributary of Moadams Creek, Class WS-V;NSW,Cape Fear River Basin Gate 6. The receiving water is reportedly impaired but a TMDL has not been established. . STORMWATER POLLUTION PREVENTION PLAN DEVELOPMENT AND IMPLEMENTATION CERTIFICATION North Carolina Division of Energy, Mineral, and Land Resources— Stormwater Program Facility Name: Alrgas USA LLC Permit Number: NCS000598 Location Address: 2025 Development Center Drive Mebane,NC 27302 County: Alamance "I certify, under penalty of law, that the Stormwater Pollution Prevention Plan (SPPP) document and all attachments were developed and implemented under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information required by the SPPP. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information gathered is, to the best of my knowledge and belief, true, accurate and complete." And "I certify that the SPPP has been developed, signed and retained at the named facility location, and the SPPP has been fully implemented at this facility location in accordance with the terms and conditions of the stormwater discharge permit." And "I am aware that there are significant penalties for falsifying information, including the possibility of fines and imprisonment for knowing violations." Sign (according to permit signatory requirements) and return this Certification. DO NOT SEND STORMWATER POLLUTION PREVENTION PLAN WITH THIS CERTIFICATION. Signature Date Thomas Stringer Vice Presldent,Production&Project Execution Print or type name of person signing above Title SPPP Certification 10/13 SUPPLEMENTAL INFORMATION REQUIRED FOR RENEWAL OF INDIVIDUAL NPDES STORMWATER PERMIT SUPPLEMENTAL INFORMATION REQUIRED FOR RENEWAL OF INDIVIDUAL NPDES STORMWATER PERMIT Two copies of each of the following shall accompany this submittal in order for the application to be considered complete: (Do not submit the site Stormwater Pollution Prevention Plan) Initials TS 1. A current Site Map from the Stormwater Pollution Prevention Plan. The location of industrial activities(including storage of materials,disposal areas,process areas and loading and unloading areas), drainage structures,drainage areas for each outfall, building locations and impervious surfaces should be clearly noted. TS 2. A summary of Analytical Monitoring results during the term of the existing permit (if your permit required analytical sampling). Do not submit individual lab reports. The summary can consist of a table including such items as outfall number, parameters sampled, lab results, date sampled,and storm event data. TS 3. A summary of the Visual Monitoring results. Do not submit individual monitoring reports.The summary can consist of a table including such items as outfall number, parameters surveyed,observations,and date monitoring conducted. TS 4. A summary of the Best Management Practices utilized at the permitted facility. Summary should consist of a short narrative description of each BMP's in place at the facility. If the implementation of any BMP's is planned,please include information on these BMP's. TS 5. A short narrative describing any significant changes in industrial activities at the permitted facility. Significant changes could include the addition or deletion of work processes,changes in material handling practices,changes in material storage practices,and/or changes in the raw materials used by the facility. TS 6. Certification of the development and implementation of a Stormwater Pollution Prevention Plan for the permitted facility(Sign and return attached form). If the final year analytical monitoring of the existing permit term has not been completed prior to filing the renewal submittal,then the last years monitoring results should be submitted within 30 days of receipt of the laboratory reports. (i.e. do not withhold renewal submittal waiting on lab results) SUPPLEMENTAL INFORMATION REQUIRED FOR RENEWAL OF INDIVIDUAL NPDES STORMWATER PERMIT(No. NCS000598) Airgas USA LLC-Mebane ASU 2025 Development Center Drive Mebane,Alamance County, NC 27302 1. Current Site Map from the Stormwater Pollution Prevention Plan See attached. 2. A Summary of Analytical Monitoring Results during the Term of the Existing Permit Airgas USA LLC- Mebane ASU was under the final phase of the construction when the current NPDES Permit(No.NCS000598)was issued in September 2019. The NPDES Permit requires that the analytical monitoring be conducted semi-annually during Period 1 from January I through June 30 and during Period 2 from July 1 through December 31 and that the first analytical monitoring period begin from Period l in 2020. There is one stormwater discharge outfall designated as Outfall 001 at the facility. The available analytical monitoring results during the current permit period are summarized below. ." i ".� vc S a'5 :.a� ''��. s s ,ge}s i �Bll n h tar �4 0 "n 2M. a r AMON (Ij1 �: 3`A ` ss( i 2�4 = Oil &Grease 15 mg/I <5.0 mg/I <15 mg/l <15 mg/I <4.9 mg/l.._ <4.9 mg/I COD 120 m <25 mg/I 26.2 m <25 mg/I <25 m l <25 mg/l TSS 100 m 1 19.9 mgtl 66.5m 1 9.5m 1 17.4m 14.2m 1 Total N/A <0.05 mg/I 0.14 mg/I 0.06 mg/I <0.05 mg/1 0.061 mg/l Phosphorus Total Nitrogen N/A <0.52 mg/I 0.73 mg/l 0.41 mg/1 1.00 mg/1 <0.349 mg/I H 6-9 s.u. 6.6 s.u. 7.1 s.u. 7.3 s.u. 6.6 mg/l 6.1 s.u. Total Rainfall 3.3 inches 2.4 inches 2.5 inches 2.5 inches 2.75 inches New Motor Oil - <55 gallons <55 gallons <55 gallons <55 gallons <55 gallons Usage It is noted that there were certain periods (Period 1 in 2020 and Periods 1 and 2 in 2021) when the analytical monitoring was not able to be conducted during the current permit period. Although the startup of the facility occurred in February 2020, the site continued to be under the final phase of construction and the stormwater discharge from the site continued to be under the construction permit for a period due to the ongoing construction activities including those in the wet pond. The final inspection under the NPDES Permit for Construction Activities was conducted in early June 2020 and the final inspection report that served as the Notice of Termination (NOT) of the NPDES Permit for Construction Activities was issued on June 5, 2020. Thus,the facility was not able to begin conducting the actual stormwater sampling under the current NPDES Permit during Period 1 in 2020 but it began from Period 2 in 2020. Page 1 of 4 Stormwater runoff from the industrial activity areas at the facility is collected in the onsite wet pond with the design capacity of approximately 112,270 ft3. Due to the design, the stormwater discharge occurs at Outfall 001 (the wet pond 18"HDPE outlet/effluent pipe) when the water level in the wet pond reaches the drawdown orifice of the riser structure. This drawdown orifice is 9 feet above the bottom of the wet pond. Due to the retention volume of the wet pond, often there is not a discharge from the wet pond even if a qualified storm event occurs. In addition, it was discovered that during a good portion of 2021,the riser structure in the wet pond leaked and Airgas investigated and corrected the identified leakage issue. For this reason,the analytical monitoring was not conducted during Periods 1 and 2 in 2021. It is noted that the analytical monitoring required in 2024 has not been conducted at the time of the NPDES Permit renewal application preparation. In accordance with the available analytical monitoring results above,the stormwater disdischarge did not exceed the benchmark values. 3. A Summary of Visual (Qualitative) Monitoring Results The NPDES Permit requires that the visual monitoring be conducted semi-annually during Period 1 from January I through June 30 and during Period 2 from July 1 through December 31. As discussed in Section 2 above, due to the construction completion progress in 2020 and due to the design and leakage issue of the onsite wet pond,there were not discharges during Period I in 2020 and during Periods I and 2 in 2021 during the current NPDES Permit period. The available visual monitoring results are summarized below. - `` .�: Y�sual,lv�eztitQri,� ;,It:�su]ts_�at�Ori�f�IltQQl..,, ' Dis6harge. es ' e`r per 7 � eo ��no"1A. 'erid� 111�112420 3U91422 1QQ1'122 i 61202 1' 18J2{123= Color Clear Clear Clear Clear Clear Odor None None None None None Clarity Clear Clear Clear Clear Clear Floating Solids Absent Absent Absent Absent Absent Suspended Solids Absent Absent Absent Absent Absent Foam Absent Absent Absent Absent Absent Oil Sheen None None None None None Erosion or deposition at the None None None None None outfall Other obvious indicators of None None None None None stormwater pollution It is noted that the visual monitoring required in 2024 has not been conducted at the time of the NPDES Permit renewal application preparation. In accordance with the visual monitoring results above, no issues are identified and it is determined that the SWPPP is effective as written and no additional control measures/best management practices are needed. Page 2 of 4 4. A Summary of Best Management Practices Stormwater Control Measures (SCMs) and structural and non-structural Best Management Practices (BMPs)employed at the facility are identified in the SWPPP and presented below. es-- -Sw f4wommmk. Wet pond * All stormwater runoff associated with industrial activities at the facility is collected in the wet pond. 0 The wet pond effluent is discharged into the nearby receiving water in a controlled manner. e The runoff flow and certain pollutants associated with settleable particles are controlled. Secondary containment * Oil-filled equipment subject to SPCC rules are provided with secondary containment; a Oil storage tanks are provided with secondary containment; 0 Water treatment chemical storage containers are provided with secondary containment; and a All oil drums are placed on the secondary containment pallets. 0 The rain water collected in a dike for the transformer is checked and released only when no oil sheen is observed. * DEF storage container is a double-walled tank and is provided with the "gun"operations with a drip pan. 0 DEF drips received in the drip pan are collected in a separate container for offsite disposal or for reuse. Minimize exposure 9 All compressors with the oil reservoirs are located in the compressor building. * All oil drums are stored indoors. * All chemicals are stored inside buildings or shelter. a Truck maintenance activities take place indoors in the maintenance shop. 0 Dunipster cover remains closed when not in use. Good housekeeping 6 All tanks are properly labeled; * Locate tanks away from areas of heavy traffic; 9 Maintain up-to-date material inventory; * Arrange for regular trash pickup; 0 Train staff in basic cleanup procedures;and 0 Encourage proper material storage techniques. Preventive maintenance * Quarterly inspection of all structures,storage tanks,catch basins,and equipment;and 9 Proper upkeep of tanks,piping and equipment Spill prevention and 0 Maintain spill response kits for each plant and restock as necessary,as response specified in the facility SPCC plan. Visual site inspections 0 Quarterly facility inspections; and and evaluation 0 Semi-annual visual observations of discharges Erosion and sediment * Stabilization of the site with gravel,stones or vegetation as needed; controls and * Silt fence,where needed. Page 3 of 4 Note: (1) Additional BMPs related to oil storage are discussed within the facility's Spill Prevention, Control, and Countermeasure(SPCC)Plan. 6. A Short Narrative Describing Any Significant Changes in Industrial Activities Since the completion of the facility construction in 2020,the facility operations largely remained the same during the current NPDES Permit period. The only change is an addition of Diesel Exhaust Fuel(DEF) operations at the facility. A DEF tote is stored outdoors and the transport truck drivers add/pump DEF into the diesel fuel tank in their trucks.Proper SCMsBMPs are employed for this operation. 6. Certification of the Development and Implementation of a SWPPP See attached. Page 4 of 4 I ATTACHMENTS TO SUPPLEMENTAL INFORMATION REQUIRED FOR RENEWAL OF INDIVIDUAL NPDES STORMWATER PERMIT • Current Site Map(Site Plan)from the Stormwater Pollution Prevention Plan • Stormwater Pollution Prevention Development and Implementation Certification SITE PLAN [Revised November 2022] LEGEND' �' 1 Pond APR.Property Line e App.Fence Line ~- General Runoff Direction • Oil Storage 6 Spill Kit �. I ----- Storm Sewer Line ® Storm Sewer Inlet /� Grass Approximate drainage area /� I for Wet Pond . . . _ . . Grass I Tinnis Creek / Wet i Acce o Pond i Truck Road. Parking Gravel I 'Outfall Truck Argon lank � � e I Lai:36°45'29"N 1 � Scal Cold eoO 0 ❑ Long:79'17"57'W O O Grass Cryogenic I Gas Tanks ompressor Bid ■ � Substation •! ■ f nsforr er Cojing / Grass (Owned by Duke ' ❑ l>r O To+fer Energy) ; 0 I _ Gravel ag rkin Office/ I . , Control Rm parking • ' ' WaterTre L. Car Parking Asphalt' Note: � , � • -- �� ■]Shop Maintenance Bldg 1. Not to scale Asphalt 2. Total property area:11.68 acres ` . -- DE1=Operations f 3. Outfall 001 drainage area: App.6.07 acres according to the design J 4. Total impervious area:App.4.11 acres,67.71%of the Outfall 001 . drainage area Access Road -" 5. Receiving water: Tinnis Creek,a tributary of Moadams Creek, . Class WS-V;NSW,Cape Fear River Basin 1 . ` _ Gate 6. The receiving water is reportedly impaired but a TMDL has not been established. STORMWATER POLLUTION PREVENTION PLAN DEVELOPMENT AND IMPLEMENTATION CERTIFICATION North Carolina Division of Energy, Mineral, and Land Resources—Stormwater Program Facility Name: Airgas USA LLC Permit Number: NCS000598 Location Address: 2025Deveiopment Center Drive Mebane.NC 27302 County: Alamarxxi "I certify, under penalty of law, that the Stormwater Pollution Prevention Plan (SPPP) document and all attachments were developed and implemented under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information required by the SPPP. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information gathered is, to the best of my knowledge and belief, true, accurate and complete." And "I certify that the SPPP has been developed, signed and retained at the named facility location, and the SPPP has been fully implemented at this facility location in accordance with the terms and conditions of the stormwater discharge permit." And "I am aware that there are significant penalties for falsifying information, including the possibility of fines and imprisonment for knowing violations." Sign (according to permit signatory requirements) and return this Certification. DO NOT SEND STORMWATER POLLUTION PREVENTION PLAN WITH THIS CERTIFICATION. Signature Date ylzv�0.2-s Thomas Stringer Vice President.Production&Project Executian Print or type name of person signing above Title SPPP Certification 10/13