HomeMy WebLinkAboutSW6230705_Design Calculations_20240304 (42) SERENTIY SCM#16 Drainage Area: 548,797 sf 12.60 ac Impervious Area: 285,107 sf 6.55 ac %Impervious: 52.0% 1 inch Storm Event: Rv=0.05+0.009 I Rv=runoff coefficient I=percent impervious Rv= 0.5176 For volume that must be controlled: Volume=3,630*Rd*Rv*A Volume required: 23,670 cf Volume provided: 25840 cf Average depth: 4.2 ft SA/DA ratio 1.52 Required surface area: 8342 sf Surface area provided: 12144 sf