Loading...
HomeMy WebLinkAboutSW6230705_Design Calculations_20240304 (32) SERENTIY 3,4 & 5 SCM 15 Drawdown Time Temporary storage volume= 28,341 cf Orifice#ldiameter= 3 in # 1 Area of orifice= 0.0491 sf Orifice Coefficient(Cd) = 0.60 Orifice elevation= 295.50 ft Water elevation= 296.79 ft Driving head(H)= 0.43 ft Discharge(Q)= 0.155123 cfs Drawdown time= 182699 s 50.7 hr 2_1 days