Loading...
HomeMy WebLinkAboutNCC233827_Site Plan or Location Map_20240105 PROJECT LOCATION gitAaINEMINIpwagrart . ►rr� '��1v&41?M 40 ��'' �, f DUKE , _I 0 A- ,.-tiv*4 fa 1 r % ., ENERGY® 44,..41,44" r es r 1 i we,,,,,Ik f i t,w Pt' CAROLINA5 NORTH & SOUTH CAROLINA STATE MAP NUCOR 100kV GREENFIELD TRANSMISSION PROJECT DAVIDSON COUNTY PROJECT NARRATIVE THE PROPOSED NUCOR 100kV GREENFIELD TRANSMISSION PROJECT IS LOCATED IN DAVIDSON COUNTY,NORTH CAROLINA.THE PROJECT L EX I N G T O N ' NC INCLUDES INSTALLATION OF A NEW 100kV TRANSMISSION LINE(1N4679 BLACK 100kV,1N4680 WHITE 100kV),APPROXIMATELY 1.5 MILES IN LENGTH.THE NEW TRANSMISSION LINE WILL BEGIN OFF OF THE EXISTING HIGH ROCK TRANSMISSION LINE(1H134/1H3229)WHEREA PROPOSED FOUR POLE BENT(T-88.5)WILL BE INSTALLED.THE PROPOSED LINE WILL THEN EXTEND NORTHWEST TO PROPOSED TOWER 7, TURN WEST TO PROPOSED TOWER 10,AND TURN NORTH UNTIL IT ENDS AT THE PROPOSED NUCOR SUBSTATION.THE PROPOSED TRANSMISSION LINE IS CROSSED BY AN EXISTING DISTRIBUTION LINE JUST EAST OF TOWER 2.THE PROPOSED LIMITS OF DISTURBANCE IS SHEET LIST: 19.13 ACRES.IN ORDER TO ACCOUNT FOR ALTERNATIVE CONSTRUCTION METHODS,OR THE NEED FOR ACCESS TO OTHER TOWERS,AN ADDITIONAL 10%OF TOTAL PROPOSED WORK AREA HAS BEEN INCLUDED IN THE PERMITTING FEE.THE ADDITIONAL 10%OF ACREAGE IS EQUAL TO 1.91 ACRES AND RESULTS IN A TOTAL AREA OF 21.04 ACRES.A PORTION OF THE SITE IS MODIFYING EXISTING TRANSMISSION TITLE SHEET SHEET PTL INFRASTRUCTURE AND WILL NOT CHANGE THE EXISTING LAND USE.THE PORTION OF THE PROJECT WITH NEW RIGHT-OF-WAY WILL REQUIRE CLEARING OF EXISTING LAND.PRIOR TO CONSTRUCTION,A DUKE ENERGY CONSTRUCTION CONTRACTOR WILL INSTALL EROSION&SEDIMENT CONTROL NOTES SHEET PEN1 EROSION CONTROL MEASURES TO ENCOMPASS THE ANTICIPATED CONSTRUCTION LIMITS.PREDEVELOPMENT CONDITIONS WILL BE EROSION&SEDIMENT CONTROL NOTES SHEET PEN2 RESTORED AND THE AREA WILL BE STABILIZED PRIOR TO COMPLETION OF CONSTRUCTION.AN AVOIDANCE AND MINIMIZATION OF START END EROSION&SEDIMENT CONTROL NOTES SHEET PEN3 DISTURBANCE APPROACH HAS BEEN INCORPORATED INTO THE DESIGN OF THE EROSION CONTROL MEASURES BY UTILIZING EXISTING ACCESS POINTS AND STABILIZED RIGHT-OF-WAY ACCESS ROUTES WHENEVER POSSIBLE.EROSION CONTROL MEASURES ARE INDICATED EROSION&SEDIMENT CONTROL OVERALL SHEET LAYOUT SHEET PLA1 HEREIN FOR PERMITTING USE ONLY BY NCDEQ.THIS PROJECT IS WITHIN THE YADKIN-PEEDEE RIVER BASIN.THE INITIAL PROJECT LATITUDE: 35°46'30" LATITUDE: 35°35'51" PROPERTY OWNER INFORMATION 1 SHEET PLA2 DURATION IS ANTICIPATED TO START IN JANUARY 2024 AND BE COMPLETED IN JUNE 2024. PROPERTY OWNER INFORMATION 2 SHEET PLA3 LONGITUDE: -80°07'56" LONGITUDE: -80°06'46" EROSION&SEDIMENT CONTROL PLAN SHEETP1 EROSION&SEDIMENT CONTROL PLAN SHEET P2 F.IEROSION&SEDIMENT CONTROL PLAN SHEET P3 KEPLEY RD (SR-2260) N EROSION&SEDIMENT CONTROL PLAN SHEET P4 EROSION&SEDIMENT CONTROL PLAN SHEET P5 GENERAL NOTES BEGINNING OF PROJECT us-sa NUCOR 100KV / EROSION&SEDIMENT CONTROL DETAILS SHEET PED1 1. APPROXIMATE STRUCTURE LOCATIONS WERE PROVIDED TO DUKE ENERGY LINE ENGINEER AND ARE FOR REFERENCE EROSION&SEDIMENT CONTROL DETAILS SHEET PED2 ONLY. THESE DRAWINGS SHALL NOT BE USED FOR LINE CONSTRUCTION. "°�1®�1.a.. EROSION&SEDIMENT CONTROL DETAILS SHEET PED3 2. BASE DRAWINGS WERE CREATED BY GIS DATA OBTAINED FROM VARIOUS SOURCES.AERIAL PHOTOGRAPHY WAS CLARKSBURY CHURCH RD (SR-2266)1- OBTAINED FROM STATE AGENCIES. .,+ 3. NOT ALL EXISTING UTILITIES ARE SHOWN. LOCATIONS SHOWN ARE APPROXIMATE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ACCURATELY LOCATE,BOTH VERTICAL AND HORIZONTAL,EXISTING UTILITIES PRIOR TO THE START RAILROAD ,A OF CONSTRUCTION.THE CONTRACTOR SHALL NOTIFY NC 811 PRIOR TO EXCAVATION. CONTRACTOR SHALL NOTIFY DUKE . -. - •' " ENERGY IMMEDIATELY IN THE EVENT OF ENCOUNTERING ANY UNDERGROUND OBSTACLE REQUIRING DEVIATION FROM 1 NC-109 THE PLAN. COST TO REPAIR DAMAGED UTILITIES SHALL BE BORNE BY THE CONTRACTOR. - "` LOWE'S DISTRIBUTION CENTER MIGRATORY BIRD HOTLINE 4. ALL UTILITIES SHALL BE PROTECTED AND REMAIN ACTIVE UNLESS OTHERWISE NOTED. CONTRACTOR SHALL NOT I STATE AND FEDERAL LAWS PROTECT ALL SPECIES OF NATIVE BIRDS FOUND THROUGHOUT THE DUKE ENERGY DISTURB UTILITY POLES,GUYS WIRES,OR ANCHORS WITHOUT PERMISSION FROM DUKE ENERGY. ''•• _. _•r I., :-�-. DISTRIBUTION LINE SERVICE AREA.INTERACTIONS OF BIRDS WITH GENERATING FACILITIES,TRANSMISSION AND DISTRIBUTIONS, 5. PROJECT IS LOCATED IN THE YADKIN-PEE DEE RIVER BASIN. THE PROJECT IS SUBJECT TO STATE-REGULATED BUFFER .NEW CUT RD (SR-2262) SUBSTATIONS,OTHER STRUCTURES AND EQUIPMENT,AND OPERATIONS ARE POTENTIALLY HARMFUL OR FATAL TO '• BIRDS. DUKE ENERGY OPERATES THESE 24-HOUR MIGRATORY BIRD HOTLINES TO ASSIST EMPLOYEES AND Z REQUIREMENTS. - ,.._(. - `= CONTRACTORS WITH RELATED INCIDENTS THAT OCCUR DURING WORK ACTIVITIES. 6. SEE SHEET PEN1 FOR EROSION AND SEDIMENTATION CONTROL(E&SC)SEQUENCE AND SEEDING SCHEDULE. 7. STREAMS EXTEND BEYOND THE RIGHT-OF-WAY. APPROPRIATE BRIDGING AND MATTING OF THESE FEATURES IS '" g.. I- CAROLINAS:800.573.3853 FLORIDA:727.386.3084 MIDWEST:317.430.4497 REQUIRED SHOULD THE CONTRACTOR USE ANY ACCESS ROUTES LOCATED OUTSIDE OF THE RIGHT-OF-WAY. 1 "° 'b' r, U) 8. ANY ALTERNATE ACCESS PLANNED BY THE CONTRACTOR SHALL BE APPROVED BY DUKE ENERGY PERMITTING PRIOR TO LOPP DR (SR-2261) USE. - ,, SPILL REPORTING HOTLINE 9. CONSTRUCTION ENTRANCES ARE SHOWN FOR REFERENCE ONLY. HEAVY MATS MAY BE USED IN LIEU OF ROCK '�EXISTI NC 100kV LINE IN ORDER TO ENSURE THE PROTECTION OF HUMAN HEALTH AND THE ENVIRONMENT,FEDERAL AND STATE LAWS Z • CONSTRUCTION ENTRANCES IF DEEMED SUFFICIENT BY A DUKE ENERGY REPRESENTATIVE. , REQUIRE THAT CERTAIN TYPES OF SPILLS AND UNPERMITTED RELEASES BE REPORTED TO THE PROPER 10. WETLAND MATTING SHALL BE COMPOSITE MATS. NO LATTICE OR TWO-PLY MATTING SHALL BE USED IN JURISDICTIONAL ' - REGULATORY AGENCIES AS SOON AS POSSIBLE FOLLOWING IDENTIFICATION.IMMEDIATELY NOTIFY YOUR WETLANDS AND/OR STREAMS. / END OF PROJECT SUPERVISOR AND THE FIELD ENVIRONMENTAUEHS PROFESSIONAL WHEN A SPILL OR UNPERMITTED RELEASE IS I- 11. NO OIL/FUEL-FILLED EQUIPMENT SHALL BE STORED OVERNIGHT WITHIN 100 FEET OF WETLANDS OR SURFACE WATER K'_.. ,'NUCOR 100KV r` DISCOVERED.IF YOU ARE UNABLE TO REACH THE FIELD ENVIRONMENTAUEHS PROFESSIONAL CONTACT ONE OF a WITHOUT CONTAINMENT. ,• WOODARD RDTHE DUKE ENERGY SPILL REPORTING HOTLINES AT: J ®'" "I '1 (SR-2264) CAROLINAS&MIDWEST:800.527.3853 W 12. SITE SHOULD BE"STORM READY"AT THE END OF EACH WORK DAY/WEEK. ; -, ''>,• ..;. ,. s"W,.,, 1 - FLORIDA:866.769.1266 LL 13. SECURE WRITTEN ACCESS AGREEMENT IS REQUIRED FOR ALL 3RD PARTY ACCESS AND PRIVATE DRIVES NOT INCLUDED Z IN ROW DOCUMENTATION PRIOR TO BEGINNING CONSTRUCTION. W 14. ALL DISTURBED AREAS SHALL BE RESTORED TO SAME OR BETTER CONDITION.PERMANENT GROUND COVER SHALL BE VICINITY MAP CONTACTS Li] USED FOR STABILIZATION. rY 15. CONTRACTOR TO FIELD ADJUST CRANE AND PULL PADS AS NEEDED FOR SAFE ACCESS UNDER EXISTING ENERGIZED SCALE:1"=1000' JEFF GOTO ENGINEER: RESPONSIBLE FOR MAINTENANCE: 0 ELECTRICAL OVERHEAR LINES. DUKE ENERGY CAROLINAS HDR ERIC SHOOK 525 SOUTH TRYON ST. ANDREW CALTON,PE PH: (336)416-9468 Y CHARLOTTE,NC 28202 440 S.CHURCH STREET Eric.Shook@duke-energy.com p PH:(760)445-3332 SUITE 1200 0 FAX:(704)382-6542 CHARLOTTE,NC S CONTRACTOR SHALL NOTIFY "NORTH CAROLINA ONE CALL' (811) Jeff.Goto@duke-energy.com PH:(980)337-5084rX OR (1-800-632-4949) AT LEAST 48 HOURS PRIOR TO 8110 andrew.calton/ hdrinc.com O BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING V D UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDED THEIR OWN LOCATOR SERVICES Z INDEPENDENT OR "NORTH CAROLINA ONE CALF. REPORT ANY ,.11'"""'r,,, DISCREPANCIES TO THE ENGINEER IMMEDIATELY. ;Q`0NGARQ42,,' LCS DUKE TITLE 20 ofesa,°.yti1% HDR Engineering Inc. NUCOR 100kV GREENFIELD TRANSMISSION INC811'M SEAL = of the Carolinas �_i742/ ''� FD/ a4o s. cnaran s1 sake 1200 ENERGY® TITLE SHEET le. q�p (. _ Charotte.NC 262D2-2D75 CAROLINAS 9+FNQINEE:,.� 704.338.6700 '"",'D7''t1N 8'GA�,10/�/.19 N.C.B.E.L.S.License Number F-0116 525 SOUTH TRYON STREET 0 10380093 10/30/2023 ISSUED FOR CONSTRUCTION FSL BNC ASC ""' '" CHARLOTTE N.C.28202 DRAWING SHEET REV FILE NO. DATE REVISION DRAWN CHECKED APPROVED TELEPHONE NO.(704)382-2741 1N$22 onEroosv 10380093 PTL