Loading...
HomeMy WebLinkAboutSW6230705_Design Calculations_20230831 (32) SERENTIY SCM#15 Drainage Area: 703,037 sf 16.14 ac Impervious Area: 308,868 sf 7.09 ac %Impervious: 43.9% 1 inch Storm Event: Rv=0.05+0.009 I Rv=runoff coefficient I=percent impervious Rv= 0.4454 For volume that must be controlled: Volume=3,630*Rd*Rv*A Volume required: 26,094 cf Volume provided: 28990 cf Average depth: 3.7 ft SA/DA ratio 1.42 Required surface area: 9983 sf Surface area provided: 16828 sf