Loading...
HomeMy WebLinkAboutSW3230303_Plansheet - Proposed Conditions/Site Plan_20230803 1 INFLUENT PUMP / NOTES. SCREENING STATION 2 [160] �� FACILITY �\ 1. THOUGH IT MAY NOT BE ILLUSTRATED, SHOWN, ® NFLUENT \ \\ LISTED, DENOTED, OR EXPRESSED THIS PLAN PUMP \ SHALL COMPLY WITH ALL PROVISIONS OF THE STATION 1 I UNION COUNTY LAND DEVELOPMENT ORDINANCE IN EFFECT AT TIME OF REVIEW AND APPROVAL. N LUEN \ (ELECTRICAL 2. UNION COUNTY WATER TO COORDINATE WITH THE 0 BUILDING \ TOWN OF WAXHAW FOR LOCATION OF PLANNED INFLUENT oX I \ PUBLIC GREENWAY EASEMENT ALONG EDGE OF JUNCTION I THE TWELVE MILE CREEK WRF PROPERTY. BOX I \ I LOCATION TO BE MUTUALLY AGREEABLE AND a I \ a AVOID INCREASED LIABILITY OR IMPACTS TO \ \\ \ z FACILITY OPERATIONS. ODOR CONTROL- 3. THERE WILL BE NO NEW STRUCTURES OR / INFLUENT[140] EXPANSIONS TO EXISTING STRUCTURES THAT ARE ' / I HUMAN OCCUPIED. TANDBY • GENERATOR tt,, RRLOCAED STANDBY \, GENERATOR, \\ I f f p w+ e O K�Ng\NG� N� STANDBY POWER • `\ ® ® GENERATOR \ • ® I 4- ®® ® FILTRATE PUMP } ®• k �! ® 0 o STATION ® ELECTRICAL I ®° • �N� ® BLOWER BUILDING 5 O ❑ BUILDING ®®e• �� _ ODOR CONTROL-SOLIDS O- 0�\ • f ❑ RAS PUMP STATION C ® ® AERATION TANK 6 Q • SOLIDS SECONDARY SECONDARY x �® • HANDLING CLARIFIER 6 CLARIFIER 5 •I BUILDING ❑ AERATION TANK 5 ODOR CONTROL-GRIT DIGESTER 4 DIGESTER 3 DIGESTER 2 RAS PUMP STATION B \ -w [480] ELECTRICAL \ o BUILDING 4 \• �® FUTURE SECONDARY SS DISTRIBUTION DISTRIBUTION D • SECONDARY CLARIFIER 4 93 BOX STRUCTURE BLOWER BUILDING 3 0 , CLARIFIER 3 r [440] I EFFLUENT BLOWER BUILDING 2 O ° ELECTRICAL OUTFALL L BUILDING 3 GRIT REMOVAL DIGESTER SECONDARY SECONDARY �1C STRUCTURE FACILITY CLARIFIER 2 CLARIFIER 1 ELECTRICAL BUILDING 2 0 • NEW MH, TYP F-I AERATION TANK 2 BLOWER BUILDING 1 x _Q ® G © CASCADE ❑ TTERS c CHEMICAL FACILITY / AERATOR RAS PUMP [740] AERATION TANK 1 I STATION A ` ° I• I EFFLUENT o I EFW PUMP STATION I / OUTFALL / STRUCTURE IN-PLANT PUMP o ❑ ► STATION WAS PUMP x ❑ TRUCK MAIN ELECTRICAL STATION I ULTRAVIOLET PARKING BUILDING DISINFECTION CANOPY ADMINISTRATION [800] BUILDING FILTER ELECTRICAL Y BUILDING v v STANDBY M X POWER X N ® X X GENERATOR PLANT N \ ® ® ENTRANCE cu ® ° ® ®® 0 0 0 ® ® 0 � ® ® ® o ® ® • Q STOCKPILE o m � AREA En \ o \ ® \ I I I SITE PLAN ®® I I 1" = 100' ® I 100 50 0 100'En z z cn SCALE: 1" = 100' w • of < U o m PROJECT ENGINEER: M. PARKER DATE: J U LY 2023 � �N CA/Y UNION COUNTY 01 DESIGNED BY: L. BENNETT =��OFESS��� 9 NORTH CAROLINA HAZEN NO.: 30831-061 z � o DRAWN BY: T. BARNES SEAL OVERALL SITE PLAN CONTRACT NO.: 1 ° 00 o N 26432 _ CIVIL U ^ CHECKED BY: J. STRUVE �, cGINE HAZEN AND SAWYER TWELVE MILE CREEK WRF DRAWING LL o w z (�7. .1 :50-0400 9101 SOUTHERN PINE BOULEVARD PROPOSED CONDITIONS NUMBER: o m Q 1 REGULATORY/BUILDING CODE 7/2023 MDP IF THIS BAR DOES NOT 0 1/2" 1" W a o MEASURE 1"THEN DRAWING CHARLOTTE, NORTH CAROLINA 28273 9.0 MGD EXPANSION C3 Z:) REV ISSUED FOR DATE BY IS NOT TO FULL SCALE ISSUED FOR CONSTRUCTION i- a