Loading...
HomeMy WebLinkAboutSW1230701_Supplement-EZ Form_20230719 SUPPLEMENT-EZ COVER PAGE PROJECT INFORMATION 1 Project Name Browns Creek Campground _2 Project Area(ac) 22 698 3 Coastal Wetland Area(ac) NA 4 (Surface Water Area(ac) 0 15 _5 Is this project High or Low Density? Low 6 Does this project use an off-site SClvl2 No COMPLIANCE WITH 02H.1003(4) 7 Width of vegetated setbacks provided(feet) 25 8 Will the vegetated setback remain vegetated? Yes 9 If BUA is proposed in the setback,does it meet NCAC 02H.1003(4)(c-d)? N/A 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 1-`:.trat!r7 System 0 12 Bioretention Cell 0 13 Wet Pond 0 14 Stormwater Wetland 0 15 Permeable Pavement 0 16 Sand Filter 0 17 Rainwater Harvesting(RWH) 0 18 Green Roof 0 19 Level Spreader-Filter Strip(LS-FS) 0 20 Disconnected Impervious SurfaceJDIS) 0 21 Treatment Swale 0 22 Dry Pond 0 23 StormFilter 0 24 Silva Cell 0 25 Bayfilter 0 26 Filterra 0 FORMS LO DESIGNER CERTIFICATION 27 Name and Title Wyatt Edsel,PE -Engineer 28 Organization: ABH Engineering,PLLC 29 Street address: 1728 9th Ave NW 30 City,State,Zip: Hickory,NC 28601 31 Phone numb er(s): 828-707-6120 32 Email: wyatt@builtbyabh.com Certification Statement: I certify,under penalty of taw that this Supplement-EZ form and all supporting information were prepared under my direction or supervision:that the information provided in the form is,to the best of my knowledge and belief.true.accurate,and complete:and that the engineenng plans. specifications,operation and maintenance agreements and other supporting information are consistent with the information provided here Designer \o w..11111//7 CAR Ai 'di ' - :0 SEAL r• Signatur Q esigner 045408 ///QEN?LE`to_ �j JZ 7/ llllllt / Date DRAINAGE AREAS 1 Is this a high density project? No 2 If so,number of drainage areas/SCMs 0 _ 3 Does this project have low density areas? Yes 4 If so,number of low density drainage areas 1 Is all/part of this project subject to previous rule 5 versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site LD 7 4 Type of SCM 5 Total drainage area(sq ft) 995259 6 Onsite drainage area(sq ft) 995259 7 Offsite drainage area(sq ft) 0 8 Total BUA in project(sq ft) 45638 sf New BUA on subdivided lots(subject to 9 permitting)(sq ft) New BUA not on subdivided lots(subject to 10 permitting)(sf) 11 Offsite BUA(sq ft) 12 Breakdown of new BUA not on subdivided lots: -Parking(sq ft) -Sidewalk(sq ft) -Roof(sq ft) -Roadway(sq ft) 30213 sf -Future(sq ft) -Other,please specify in the comment box below(sq ft) New infiltrating permeable pavement on 13 subdivided lots(sq ft) New infiltrating permeable pavement not on 14 subdivided lots(sq ft) Existing BUA that will remain(not subject to 15 permitting)(sq ft) 15470 sf 16 Existing BUA that is already permitted(sq ft) 17 Existing BUA that will be removed(sq ft) 18 Percent BUA 5% 19 Design storm(inches) 20 Design volume of SCM(cu ft) 21 Calculation method for design volume ADDITIONAL INFORMATION Please use this space to provide any additional information about the 22 drainage area(s): LOW DENSITY DESIGN REQUIREMENTS FOR LOW DENSITY PROJECTS FROM 02H.1003 1 Is project below density thresholds set forth in the applicable stormwater rule? Yes 2 Does project maximize dispersed flow and minimize channelization of flow? Yes 3 Has the use of piping been minimized per.1003(2)(c)? Yes 4 Side slopes of the vegetated conveyances(H:V) 3:1 5 Maximum velocity in the vegetated conveyances during the 10-year storm? 3.13 6 Are curb outlet swales proposed? No 7 Maximum longitudinal slope of curb outlet swale(s)(%) 8 Bottom width of curb outlet swale(s)(feet) 9 Maximum side slope of curb outlet swale(s)(H:V) 10 Minimum length of curb outlet swale(s)(feet) 11 Are treatment swales used instead of curb outlet swales? 12 Is stormwater released at the edge of the setback as dispersed flow? Yes 13 Have stormwater outlets been designed to prevent downslope erosion? Yes 14 Are variations to rule.1003 proposed? No ADDITIONAL INFORMATION 15 Please use this space to provide any additional information about this low density project: Drainage Pervious Swale BUA Q Slope V,i„w V,tt,,,i Flow depth # Area area (ac) (cfs) (%) (fps) (fps) (ft) (ac) (ac) 1 0.45 0.04 0.41 61.00 1.54 12.60 8.00 2.35 0.33 2 2.20 0.15 2.06 61.00 6.76 2.83 2.00 1.95 0.79 3 0.80 0.06 0.75 61.00 2.80 18.52 8.00 3.08 0.34 4 0.26 0.05 0.21 66.00 1.09 14.29 8.00 2.24 0.27 5 0.25 0.05 0.19 66.00 1.07 6.00 2.00 1.65 0.38 6 1.45 0.12 1.33 61.00 4.50 5.36 8.00 2.29 0.82 7 0.38 0.05 0.33 63.00 1.16 5.24 2.00 1.61 0.42 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30