Loading...
HomeMy WebLinkAboutNCS000101_BIMS Inspection Rpt_20230717 Compliance Inspection Report Permit:NCS000101 Effective: 12/01/14 Expiration: 11/30/19 Owner: International Paper Company SOC: Effective: Expiration: Facility: Riegelwood Mill County: Columbus 865 John L Reigel Rd Region: Wilmington Riegelwood NC 28456 Contact Person:Louis O Grissom Title: Phone: 910-655-6229 Directions to Facility: System Classifications: SWNC, Primary ORC: Certification: Phone: Secondary ORC(s): On-Site Representative(s): Related Permits: Inspection Date: 07/17/2023 Entry Time 10:OOAM Exit Time: 12:20PM Primary Inspector:Brian P Lambe Phone: Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Stormwater Discharge, Individual Facility Status: Compliant ❑ Not Compliant Question Areas: Storm Water (See attachment summary) Page 1 of 3 Permit: NCS000101 Owner-Facility:International Paper Company Inspection Date: 07/17/2023 Inspection Type:Compliance Evaluation Reason for Visit: Routine Inspection Summary: Reviewed comments from IP regarding the draft permit and the list of significant changes to the permit 2. Permittee did not have any ug/L and was confused on the relevance. 7. IP says outfall L is to be removed from the permit. 8. SWO16 (Basin M) is separated from the rest of the outfalls to include methanol sampling.IP contends that the methanol is in secondary containment and if there was an issue, the area drains wastewater treatment. 9.SW023 Basin T-long term solutions to this outfall is to 1)prove to this office that the drainage does not discharge or 2) combine with other outfalls downstream (this will need a study to see if outfall is viable). IP has a question regarding the non polar oil&grease for drainage areas that use >55 gallons per month on average. IP does not want to disclose the total quantity of Monthly Oil Usage at the facility for propietary reasons and feasiblility of collecting that data. They do not know how to define which outfalls will be tested for O/G. Page 2 of 3 Permit: NCS000101 Owner-Facility:International Paper Company Inspection Date: 07/17/2023 Inspection Type:Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? ❑ ❑ ❑ #Does the Plan include a General Location (USGS) map? ❑ ❑ ❑ #Does the Plan include a"Narrative Description of Practices"? ❑ ❑ ❑ #Does the Plan include a detailed site map including outfall locations and drainage areas? ❑ ❑ ❑ #Does the Plan include a list of significant spills occurring during the past 3 years? ❑ ❑ ❑ #Has the facility evaluated feasible alternatives to current practices? ❑ ❑ ❑ #Does the facility provide all necessary secondary containment? ❑ ❑ ❑ #Does the Plan include a BMP summary? ❑ ❑ ❑ #Does the Plan include a Spill Prevention and Response Plan (SPRP)? ❑ ❑ ❑ #Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ❑ ❑ ❑ #Does the facility provide and document Employee Training? 0 ❑ ❑ ❑ #Does the Plan include a list of Responsible Party(s)? 0 ❑ ❑ ❑ # Is the Plan reviewed and updated annually? 0 ❑ ❑ ❑ #Does the Plan include a Stormwater Facility Inspection Program? 0 ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? 0 ❑ ❑ ❑ Comment: Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring? 0 ❑ ❑ ❑ Comment: Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? 0 ❑ ❑ ❑ #Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ ❑ 0 ❑ Comment: Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? 0 ❑ ❑ ❑ #Were all outfalls observed during the inspection? ❑ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ ❑ #Has the facility evaluated all illicit(non stormwater)discharges? 0 ❑ ❑ ❑ Comment: Page 3 of 3