Loading...
HomeMy WebLinkAboutNCS000567_Inspection Report_20230510ROY COOPER Governor ELISABETH BISER Secretary DOUGLAS ANSEL Interim Director 1 NORTH CAROLINA Environmental Quality May 10, 2023 Ecoflo Inc Attention: Preston Black, Environmental Compliance Manager 2750 Patterson Street Greensboro, NC 27407 Subject: Compliance Evaluation Inspection Ecoflo Inc NPDES Certificate of Coverage — NCS000567 Guilford County, North Carolina Dear Mr. Black: Enclosed please find a copy of the Compliance Evaluation Inspection Report for the inspection we conducted at the Greensboro Ecoflo facility on April 27, 2023. Please note that in the stormwater inspection report summary we ask that you take the appropriate corrective actions for the deficiencies noted in the inspection report. The report should be self-explanatory; however, should you have any questions, please do not hesitate to contact Lily Kay at (336) 776-9655 or by E-mail at lily.kay@ncdenr.gov. Sincerely, 7 amera Epli , PE Regional Engineer Land Quality Section Enclosure c: Laserfiche North Carolina Department of Environmental Quality I Division of Energy, Mineral, and Land Resources FM Q. Winston-Salem Regional Office 1 450 W Hanes Mill Road, Suite 3001 Winston-Salem, North Carolina 27105 336-776-9800 Compliance Inspection Report Permit: NCS000567 Effective: 01/01/16 Expiration: 12/31/20 Owner: Ecoflo Inc SOC: Effective: Expiration: Facility: Ecoflo, Inc. County: Guilford 2750 Patterson St Region: Winston-Salem Greensboro NC 274072317 Contact Person: Preston Black Title: Phone: 336-617-2714 Directions to Facility: System Classifications: SWNC, Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 04/27/2023 Primary Inspector: Lily C Kay Secondary Inspector(s): Entry Time 09:40AM Reason for Inspection: Routine Permit Inspection Type: Stormwater Discharge, Individual Facility Status: ❑ Compliant ❑ Not Compliant Question Areas: Storm Water (See attachment summary) Certification: Phone: Exit Time: 11:OOAM Phone: 704-663-1699 Inspection Type: Technical Assistance Page 1 of 3 Permit: NCS000567 Owner - Facility: Ecoflo Inc Inspection Date: 04/27/2023 Inspection Type : Technical Assistance Reason for Visit: Routine Inspection Summary: The Stormwater Pollution Prevention Plan (SWPPP) and related documentation was complete including employee training records, inspection records, and the annual certification. The facility appeared well operated and maintained except the unstabilized area in the back of the facility that could contribute to the TSS exceedances. Outlet 2 was located outside the back fence and could be eliminated if the stormwater is directed to the front of the site, but should be sampled until that time. If you have questions, contact me at Lily. Kay@ncdenr.gov or by phone at (336) 776-9655. Page 2 of 3 Permit: NCS000567 Owner - Facility: Ecoflo Inc Inspection Date: 04/27/2023 Inspection Type : Technical Assistance Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? 0❑ ❑ ❑ # Does the Plan include a General Location (USGS) map? 0❑ ❑ ❑ # Does the Plan include a "Narrative Description of Practices"? 0 ❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? 0 ❑ ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? ❑ ❑ ❑ # Has the facility evaluated feasible alternatives to current practices? ❑ ❑ ❑ # Does the facility provide all necessary secondary containment? 0 ❑ ❑ ❑ # Does the Plan include a BMP summary? 0 ❑ ❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? 0 ❑ ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? 0 ❑ ❑ ❑ # Does the facility provide and document Employee Training? ❑ ❑ ❑ # Does the Plan include a list of Responsible Party(s)? ❑ ❑ ❑ # Is the Plan reviewed and updated annually? 0 ❑ ❑ ❑ # Does the Plan include a Stormwater Facility Inspection Program? 0 ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? 0 ❑ ❑ ❑ Comment: The Stormwater Pollution Prevention Plan (SWPPP) and related documentation was complete includingemployee employee training records, inspection records, and the annual certification. Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring? 0 ❑ ❑ ❑ Comment: Qualitative monitoring records were available and complete Analytical Monitorinq Yes No NA NE Has the facility conducted its Analytical monitoring? 0 ❑ ❑ ❑ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? 0 ❑ ❑ ❑ Comment: Analytical monitorinq records were available and complete, but the facilitv is in Tier 2 for TSS. This exceedance was attributed to a wood fines bin used to solidify liquids. Permit and Outfalis Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? 0 ❑ ❑ ❑ # Were all outfalls observed during the inspection? 0 ❑ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ ❑ # Has the facility evaluated all illicit (non stormwater) discharges? ❑ ❑ ❑ Comment: Previous inspections failed to locate outlet 2, but there is a storm drain outside the fence in the back of the facility. The facility could eliminate this outfall by grading this area to ensure all stormwater flows to the front of the facility. This area was also lacking sufficient vegetation to restrain sediment on site and could be a contributing factor to the TSS exceedances. This area should be stabilized with vegetation, mulch, rock, or hardscaping. Page 3 of 3