Loading...
HomeMy WebLinkAboutSW8070544_Historical File_20070703Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen H. Sullins, Director Division of Water Quality July 3, 2007 Kyle Corkum, Manager Waterboro Village, LLC 5511 Capital Center Drive, Suite 105 Raleigh, NC 27606 Subject: Stormwater Permit No. SW8 070544 Waterway Cove High Density Subdivision Project Brunswick County Dear Mr. Corkum: The Wilmington Regional Office received a complete Stormwater Management Permit Application for Waterway Cove on June 29, 2007. Staff review of the plans and specifications has determined that the project, as proposed, will comply with the Stormwater Regulations set forth in Title 15A NCAC 21-1.1000. We are forwarding Permit No. SW8 070544, dated July 3, 2007, for the construction of the project, Waterway Cove. This permit shall be effective from the date of issuance until July 3, 2017, and shall be subject to the conditions and limitations as specified therein. Please pay special attention 'to the Operation and Maintenance requirements in this permit. Failure to establish an adequate system for operation and maintenance of the stormwater management system will result in future compliance problems. If any parts, requirements, or limitations. contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within thirty (30) days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, P.O. Drawer 27447, Raleigh, NC 27611-7447. Unless such demands are made this permit shall be final and binding. If you have any questions, or need additional information concerning this matter, please contact Chris Baker, or me at (910) 796-7304. Sinc ely, <��'s Edward Beck Regional Supervisor Surface Water Protection Section ENB/csb: S:1INQSISTORMWATIPERMIT1070544.ju107 cc: Reuben S. Jones, III, P.E., Milone & MacBroom Brunsiwck County Inspections Division of Coastal Management Chris Baker Wilmington Regional Office W�p&Carolina Central Files Naturally North Carolina Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 Phone (919) 733-7015 Customer Service Internet: www.ncwaterguality.org Location: N. 512 Salisbury St. Raleigh, NC 27604 Fax (919) 733-2496 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer— 50% Recycled/10% Post Consumer Paper State Stormwater Management Systems Permit No. SW8 070544 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY SUBDIVISION DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Kyle Corkum and Waterboro Village, LLC Waterway Cove NC 1791904, Brunswick County FOR THE construction, operation and maintenance of 3 large capacity underground infiltration trenches and 130 small capacity underground infiltration trenches in compliance with the provisions of 15A NCAC 2H .1000 hereafter referred to as the "stormwater rules') and the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Water Quality and considered a part of this permit. This permit shall be effective from the date of issuance until July 3, 2017, and shall be subject to the following specified conditions and limitations: I. DESIGN STANDARDS 1. This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data. 2. This stormwater system has been approved for the management of stormwater runoff as described in Section 1.7 on page 3 of this permit. The subdivision is permitted for 133 single family lots, each allowed 2,500 square feet of built -upon area, 54 townhome units, each allowed 1,525 square feet of built -upon area, and 46 lots, each allowed 1,725 square feet of built -upon area. 3. The stormwater control has been designed to handle the runoff from a total of 832,679 square feet of impervious area. 4. The tract will be limited to the amount of built -upon area indicated on page 3 of this permit, and per approved plans. 5. All stormwater collection and treatment systems must be located in either dedicated common areas or recorded easements. The final plats for the project will be recorded showing all such required easements, in accordance with the approved plans. Page 2 of 8 State Stormwater Management Systems Permit No. SW8 070544 6. The runoff from all built -upon area within. the permitted drainage areas of this project must be directed into the permitted stormwater control system. 7. The following design criteria have been provided in the infiltration trench and must be maintained at design condition: Infiltration Trench S stem INF-100 INF-200 INF-300 Type A Type B Type C Type D Type E a. Drainage 9.76 10.43 4.57 ** See ** See ** See ** See ** See Area, acres Attachment Attachment ` Attachment Attachment Attachment Onsite, fl 425,216 454,217 199,086 Offsite, ft None None None None None None None None b. Total 213,162 241,417 105,000 ** See ** See ** See ** See ** See Impervious Attachment Attachment Attachment Attachment Attachment Surfaces, ft"A„ "B„ "C° "D„ "E„ c. Design 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 Storm, inches d. Trench 275x32 220x 135x 40x4x 51 x4x 70x4x 20x8x4 30x84 Dimensions, x 5 44 x 5 82 x 2.8 5.58 4.34 2.79 LxWxH,ft e. Perforated 48/1,375 48/1540 15/4725 ** See ** See ** See ** See ** See Pipe Diam./ Attachment Attachment Attachment Attachment Attachment Length,in/ft "A" "B" TIN "D" "E" f. Bottom 30 31 13.3 ** See ** See ** See ** See ** See Elevation, Attachment Attachment Attachment Attachment Attachment FMSL"A" "B" "C„ "D" "E„ g. Bypass 35 36 16.1 ** See ** See ** See ** See ** See Weir Attachment Attachment Attachment Attachment Attachment Elevation, "A" "B" "C" "D" "E„ FMSL h. Permitted 29,650 30,185 12,230 893 885 781 640 960 Storage Volume, ft i. Type of Wando Wando Wando Wando Wando Wando Wando Wanda Soil j. Expected 6 6 6 6 6 6 6 6 Infiltration Rate, in/hr k. Seasonal 28 29 11.3 ** See ** See ** See ** See **See Hi. Water Attachment Attachment Attachment Attachment Attachment Table, FMSL "A" "B" "C" "D" "E" 1. Time to 30 30 16.8 38.4 26.4 16.8 24 24 Draw Down, hours m. Receiving Stream/River Basin Intracoastal Waterway/Lumber n. Stream Index Number 15-25 o. Classification of Water Body SA;HQW ** Defer to the assigned attachment for specific details of individual lots and townhome units to be treated on site. If. SCHEDULE OF COMPLIANCE 1. The stormwater management system shall be constructed in its entirety, vegetated and operational for its intended use prior to the construction of any built -upon surface. Page 3 of 8 State Stormwater Management Systems Permit No. SW8 070544 2. During construction, erosion shall be kept to a minimum and any eroded areas of the system will be repaired immediately. 3. The facilities shall be constructed as shown on the approved plans. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 4. If the stormwater system was used as an Erosion Control device, it must be restored to design condition prior to operation as a stormwater treatment device, and prior to occupancy of the facility. 5. The permittee shall at all times provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency. The approved Operation and Maintenance Plan must be followed in its entirety and maintenance must occur at the scheduled intervals including, but not limited to: a. Semiannual scheduled inspections (every 6 months). b. Sediment removal. C. Mowing and revegetation of slopes and the vegetated filter. d. Immediate repair of eroded areas. e. Maintenance of all slopes in accordance with approved plans and specifications. f. Debris removal and unclogging of bypass structure, filter media, flow spreader, catch basins, piping and vegetated filter. g. A clear access path to the bypass structure must be available at all times. 6. Records of maintenance activities must be kept and made available upon request to authorized personnel of DWQ. The records will indicate the date, activity, name of person performing the work and what actions were taken. 7. Upon completion of construction, prior to issuance of a Certificate of Occupancy, and prior to operation of this permitted facility, a certification must be received from an appropriate designer for the system installed certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting documentation. Any deviations from the approved plans and specifications must be noted on the Certification. A modification may be required for those deviations. 8. Access to the stormwater facilities shall be maintained via appropriate easements at all times. 9. The permittee shall submit to the Director and shall have received approval for revised plans, specifications, and calculations prior to construction, for any modification to the approved plans, including, but not limited to, those listed below: a. Any revision to any item shown on the approved plans, including the stormwater management measures, built -upon area, details, etc. b. Project name change. C. Transfer of ownership. d. Redesign or addition to the approved amount of built -upon area or to the drainage area. e. Further subdivision, acquisition, lease or sale of all or part of the project area. The project area is defined as all property owned by the permittee, for which Sedimentation and Erosion Control Plan approval or a CAMA Major permit was sought. f. Filling in, altering, or piping of any vegetative conveyance shown on the approved plan. Page 4 of 8 State Stormwater Management Systems Permit No. SW8 070544 10. The permittee shall submit final site layout and grading plans for any permitted future areas shown on the approved plans, prior to construction. 11. A copy of the approved plans and specifications shall be maintained on file by the Permittee for a minimum of ten years from the date of the completion of construction. 12. The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit. Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements. The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made. 13. Prior to the sale of any lot, the following deed restrictions must be recorded: a. The following covenants are intended to ensure ongoing compliance with State Stormwater Management Permit Number SW8 070544, as issued by the Division of Water Quality under NCAC 2H.1000. b. The State of North Carolina is made a beneficiary of these covenants to the extent necessary to maintain compliance with the Stormwater Management Permit. c- These covenants are to run with the land and be binding on all persons and parties claiming under them. d. The covenants pertaining to stormwater may not be altered or rescinded without the express written consent of the State of North Carolina, Division of Water Quality. e. Alteration of the drainage as shown on the approved plans may not take place without the concurrence of the Division of Water Quality. The maximum built -upon area per lot is 2,500 square feet for 133 single family lots, 1,525 square feet for 54 townhome units, and 1,725 square feet for 46 townhome units. This allotted amount includes any built -upon area constructed within the lot property boundaries, and that portion of the right-of-way between the front lot line and the edge of the pavement. Built upon area includes, but is not limited to, structures, asphalt, concrete, gravel, brick, stone, slate, coquina and parking areas, but does not include raised, open wood decking, or the water surface of swimming pools. g. Lots within CAMA's Area of Environmental Concern may be subject to a reduction in their allowable built -upon area due to CAMA regulations. h. All runoff on the lot must drain into the permitted system. This may be accomplished through providing roof drain gutters which drain to the street, grading the lot to drain toward the street, or grading perimeter swales and directing them into the pond or street. Lots that will naturally drain into the system are not required to provide these extra measures. Built -upon area in excess of the permitted amount will require a permit modification. Page 5 of 8 State Stormwater Management Systems Permit No. SW8 070544 14. A copy of the recorded deed restrictions must be submitted to the Division within 30 days of the date of recording the plat, and prior to selling lots. The recorded copy must contain all of the statements above, the signature of the Permittee, the deed book number and page, and the stamp/signature of the Register of Deeds. III. GENERAL CONDiTiONS This permit is not transferable except after notice to and approval by the Director. In the event of a change of ownership, or a name change, the permittee must submit a formal permit transfer request to the Division of Water Quality, accompanied by a completed name/ownership change form, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. The permittee is responsible for compliance with all permit conditions until such time as the Division approves the transfer request. 2. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to enforcement action by the Division of Water Quality, in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. 3. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances, which may be imposed by other government agencies (local, state, and federal) having jurisdiction. 4. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement stormwater management systems. 5. The permittee grants DENR Staff permission to enter the property during normal business hours for the purpose of inspecting all components of the permitted stormwater management facility. 6. The permit may be modified, revoked and reissued or terminated for cause. The filing of a request for a permit modification, revocation and reissuance or termination does not stay any permit condition. 7. Unless specified elsewhere, permanent seeding requirements for the stormwater control must follow the guidelines established in the North Carolina Erosion and Sediment Control Planning and Design Manual. 8. Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the permit. 9. The permittee shall notify the Division any name, ownership or mailing address changes within 30 days. Permit issued this the 3rd day of July, 2007. NO CAROLIN�/I13,0NMENTAL MANAGEMENT COMMISSION ror yoieen H. sunrns, uirector Division of Water Quality By Authority of the Environmental Management Commission Page 6 of 8 State Stormwater Management Systems Permit No. SW8 070544 Waterway Cove Stormwater Permit No. SW8 070544 Brunswick County Designer's Certification I, , as a duly registered in the State of North Carolina, having been authorized to observe (periodically/ weekly/ full time) the construction of the project, (Project) for (Project Owner) hereby state that, to the best of my abilities, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications. The checklist of items on page 2 of this form is included in the Certification. Noted deviations from approved plans and specification: Signature Registration Number Date SEAL Page 7 of 8 State Stormwater Management Systems Permit No. SW8 070544 Certification Requirements: .1. The drainage area to the system contains approximately the permitted acreage. 2. The drainage area to the system contains no more than the permitted amount of built -upon area. 3. All the built -upon area associated with the project is graded such that the runoff drains to the system. 4. All roof drains are located such that the runoff is directed into the system. 5. The bypass structure elevations are per the approved plan. 6. The bypass structure is located per the approved plans. 7. A Trash Rack is provided on the outlet/bypass structure. 8. All slopes are grassed with permanent vegetation. 9. Vegetated slopes are no steeper than 3:1. 10. The inlets are located per the approved plans and do not cause short- circuiting of the system. 11. The permitted amounts of surface area and/or volume have been provided. 12. All required design depths are provided. 13. All required parts of the system are provided. 14. The required system dimensions are provided per the approved plans. cc: NCDENR-DWQ Regional Office Brunswick County Building Inspections Page 8 of 8 w W Y u w, , m m _ S p O Om1 m m N N { Oy { Oy { my M N W W W r J Z W W A m m m m' W m W OD m YD t0 W m W a0 m m W A W m m W CO ED 0 W W ro m 0p m L OR f �r O a •> O Lu �M{yy M Q INO Q tN0 m IO W CNI O tM'! O CN! W CNl n (N9 (O{ByI P'1 (W� C] ANmy l7 1�py tf O M O t+Nl m fM•! m tM�l O tM9 ({gyp t7 Q tM'! m IN9 N tN�l N (N9 N CN] W M any t+l n l•Nl W M W tN+f W IN+I m lN/ O tM�! Yf tN�l O tM9 A INO A C AI t•! A M J 9 u m i a a W M o WW W o o c c o o c c o c c o 0 0 o c c o o c o d o o c o 0 o c c o o c o o c c o RO 1� N N Ilim W Ltf u'1 r C U '6 1e U m d p+ U yl [9 t�l M N t•! I+l V Q t7 t�l � C! M M M M M Q M M M M M M M M t+l t9 th pl C O G O G O O O O O O O O O C O O O O O O O O O O O G O O O O O Q O O O G C O C II K Of U �' A tWU N On1iOD. �p p�p e� a� a W O WW {�� t+l p� Q (�p Q ag 0 W� O ryaO p� �p eQ� e Y E N t0 �IMpO t9 Y tM9 Cl R I M M N M M a H N N N 0 wCL m� � mN t•1 a t+l M � n fM9 n 19 M t0 � t+i �� 9 J a w O OU N OU N N p ff N p b N p N N YOf N N N h N pU N pU N Ypl N N N p N N p m N S N S N S YOi N h I pU o U S N 8 l! p N OU Ypf p O N OU OU p O N p O N p OoN 7 m N N N N N N N N N N N N N N N N R' a O Yn N m m W m W m' m W 10 N v r p aN1 r IrOIr�� N W M P N A M m n W m oI N Q n W N n m u�i vl Q W H �i O m IU {y s m IU m O A to N m O N W �p YMj W m N n W m r IU n m n YI r IU r N O O O O O m Q IU Q u'f V W W J 2 f0 N N m N N o N o N p N o N 0 N 0 fWV 0 N o N p N o N 0 N 0 N o N p N o N 0 N 0 N 0 N 0 N 0 N o N p N o N N ry N In N o N 0 N 0 N 0 N 0 N i m1pp {V { op N 0 N O a F O O In9 m P] O (m9 pOm M O •W9 O M O On! O W O In9 O ln'1 O M O (O� (9 1OU lry O M O M O I9 W N O 1 O M • O OOIU p Nn O O W O O J W 1 1 0 lm4 i0 O F In m { O� Amryy Iq m I�ryr u� N m m m m N In Y1 m Iq h N N m m m m Yi m IU IU O N of of m IOOU m IU O m J W '� Pl t7 {•1 M I•f lNq M OJ W l�/ {9 M N N N I7 1N9 M N g t7 N N N N N IO+I M N Pf t7 W M M C') pO t•! N N i! N M Q IU W A W m O N M W N N { N N N N N N N N W h d m d m (Ny ;s m p m m tWD m r 0 W wLLJ O O 0 J 0 A � O Im•1 0 w W?5 Fs m O a x z? W ` J m v W 0 O b u ,ri 2 C _ Q W� U> W o0 m m m m aA0 W m W Op m m 0D m m W m OD O W II O Q O LFN p v v v a dl OI Y 10 N m W W N N N W W W ft0� J O > 0 y p yy pp O O G O O G O O O o O O C O O O O C C O 3 W I N — N N N N N N N N N N N N W IC C YI } W W W m OI W N 0 W Ol Nl W N W W A O! A W W W W W 0 W O C 11 G O C G G G a G G 0 C 0 O O O G 0 0 G G 0 O O O O 0 � o � 2pe� � 3Z Y 2y4 a ee X X � X R S4 a X 24 3E aC f� pX {2�e t00 fAD N O N W OaAi OA1 O ��p CO fp W OaNI {{�� �1p0 �INpO �W{ ON aW 4 J 0 pO 0 pQ 0 oo g g g g O 0 O 0 o 0 0 0 0 0 0 o 0 0 0 0 0 0 0 0 0 0 0 0 J� 7 In N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N IA n N 0 0 0 O O' h IA h fN(pp aN0 oND aND aD t(NtyyO O J O O m O ON O WNN O WNN O WN N N N O ON O ON O C0 O O O O WI�0V O O O M N4WN N N N N L O a F o 0 0 0 0 0 N N N o 0 0 0 0 0 0 0 0 0 0 w J W 20 O f m YI N N R g h 0 0 0 N N N on 10 N N y Ny op N N N W J W N W b M !7 W W W N W MN fN9 M N (7 N N N ~ N pl Ytw He A A A W op W W W W l0 W OI O! W N W w O W O N>a o o W ? O x 0 J qo W � � x &§P- §6; §UJ by §§F..�a■ §§ d> k|« 2� ______ $/ k\ nIsc;i w a , .9 8 e e ..,, .69 mm; K< § I®2§N■2§ «, §! co CL�! LLJ C4 m v w v (�� _..� „ LLJ §• „ ass;;, §§N , �90 a §§§, ■ w Ix ° a. §J! § | lu ; ] § LLI _ wIP- §§; /z{ (� B> mm,�„| §§|;2222 R> J+ &2 R§¥mq¥ )�, •r■■§q$ � ■. §|m§§§■ §! §§§§2|J 6 k§! 2§2]§§§ 2§ §§ §§§IN §- ;G\§cd §)§� 2 w>2 w§ 2 §§E : k�# § . WElr m m 0 N N (p yy77 2NN N N N N N N N N N N N N 1�pp� N�pp 2 N N NN N s N a N N N (NV (NV N fV N C' H y J a 0 0 o O o 0 0 0 ss S o 0 0 0 Ric 0 o O o O o O o O 0 0 U C 00 moo pl moo c 7 >~ m Q a> a � @ O m o y m a O O S S S 8 O O O O O O O O N `a88888. N N N N N m N tto11 to)o m G o 0 0 0 o C O o o C C o 0 0 o o o 0 o 0 0 0 0 0 0 o o O C o W }AD W O+ m N W N W N N W W N W N N W W O! W Ol N W N W N N W W N W N N W W N N W W N W N W Of Of O1 Ol Cg >C o o c o o c c o 0 0 0 0 o c o 0 0 0 0 0 0 0 o c o 0 o c c c o o m 'E X g S X o g X s g g g X o$ 2E g$ g X X g$ o g g g g g X g S a o X g g g X d o 0 99 o o $cSc o 8880000cc 0 0 o O $ o o o0E 9 o g 00 a T rrTrrTrTTrr-Trr-rrT TrrTrr J rn Q 8 w N 1N N N N h N N N YS N N N N N N N N N N N N N N N N N N N N b N N N N YS N N N N N N N N N N N N N N N N N N N _ a T T T r T r T .- T r T T r T r T r r r T T T T r T T r T T D m Q W of F N NN N N N N N N N N N N N N N 1q N N N N N 1N tN0 N N N N N O J N mm m m fp m r r (O r 10 T T f0 O r O fD l+7 0 Of l0 lC W {7 I� fG a0 o g m V fV m m {7 Q m N m W N 10 m fC T q A Cl W OG r O T 0 Q? W Ol O Ol Of Oi OD CG OG I� o h O lV fV o fV N {7 M v w w I- 0 0 W T T T .- T T � T r T T r T T T � P Qj r � T T T r T r T T T T J W Z 29 ❑ F a O N O O N o O �a O N N? N Q O 'Q N O N N N o O N C 0 0 0 0 0 0 0 0 0 N O O N N N O' r r T r r r r V r r: e- T r y aG aG f� Iri fC I� m m Qi O! C N fV f`7 Y C m J� W 2 0 �i 8 m v `a a in uNi v°ii 8 8 ti m 8 m. m rn O H 2 F _ W 2 2 p € m m Z ❑ m I all IIIIxIzaIII13zz o Q m m m m m m m m m m m m m m m m m m m m m m m �a c V J ~ ❑ mQ O SIsalsIm8iSm,mi8S8mS01��������� O O O O O O O O O O O O O O O � o Ea @ o ~ N N N N N N N N N N N N N N N N N N N N N N N N N N W h Kl N 10 N 0 H'n 'n w H In In Na woff N10 N NU) N� Elor � u F W Q •� •� N o'a000ac1lN � N� N `a`S`8`8`8'8`80000a0000 In m 10 1n m N Iq m m o ID ID � � N N N N N N N N N N N N N N N N N N N N N N N N N N s t00 r W o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 oi 0 I I l o0o � i li 0aaagaaaaaaaa9aall'll1Oda N m N m 1q N o o Ln iq LqN N R N N N Iq RR tq N KI N wi W K .. C W 'i5 W 01 o + mmmmmmmmmmmmmmmmmmmmmiOmmmmm m o o c o 0 0 0 0 o c c c o 0 o c c o 0 o o o 0 o 0 o c o u K � X�R f, e. X X 88888SS8888888888888888888 o 0 0 g g g 8 8 g o 0 0 0 0 0 0$ 0 c 0 c 0 c c 0 0 o 0 0 0 o g 0 g$ o 0 E W —a r r r r r r r r r r r r r r r r r r r r r r r r w J N g b N O In m m h�y h O A m N h A A w n w w n hN w N o N w N N N w h N N N N N N _ Q 7 r r r r r r r r r r r r r r r r r r r r r m QQ W N N N N m mN� m N N N yD N N N N N N N N N N N N N N N O J 2 N fV m I'R I p f0 m r m CD cD a0 m a0 m aD m CO m wl N co iV t0 o tq m m ui w m m m m m 1.- 6 m 6 r y Z O a P OF m -1 m o o m A ui o 0 0 0 0 Ln o 0 0 0 0 0 o a o �n �n F Oi r Oi r r Oi Oi r r f r r F 12 tri r r :2 r :2 r N r Qj o r fV fV r r C7 pl r r N 1� r r I� r aC m r r J W Z O 0¢' o o— u7 wn N N o o m v � � o o C in (2 o 0 r 0 0 0 wn o 0m p � W m m I, Lod m m m J W W E O mgv��ww2m`9D S ;s(D a3Immma`Tm O m Z w J x a S S ❑ z m 2 W OFFICE USE ONLY Date Received Fee Paid Permit Number ryovo 10 2 Z LJ8 0 State of North Carolina Department of Environment and Natural Resources Division of Water Quality STORMWATER MANAGEMENT PERMIT APPLICATION FORM This form may be photocopied for use as an original I. GENERAL INFORMATION 1. Applicants name (specify the name of the corporation, individual, etc. who owns the project): Waterboro Village, LLC 2. Print Owner/Signing Official's name and title (person legally responsible for facility and compliance): Kyle Corkum, Manager 3. Mailing Address for person listed in item 2 above: 5511 Capital Center Drive, Suite 105 City: Raleigh Telephone Number: ( 919 ) 256-1981 State: NC Zip: 27606 4. Project Name (subdivision, facility, or establishment name - should be consistent with project name on plans, specifications, letters, operation and maintenance agreements, etc.): Waterway Cove 5. Location of Project (street address): NC Highway 179/904 at SR 1232 City: Ocean Isle Beach County: Brunswick 6. Directions to project (from nearest major intersection): Approximately 0.6 miles west of the Hwy. 179 & Hwy. 904 Intersection 7. Latitude: 33053' 54" N Longitude: 780 27' 03" W of project 8. Contact person who can answer questions about the project: Name: Reuben Jones Telephone Number: ( 919 ) 854-4373 IT. PERMIT INFORMATION: 1. Specify whether project is (check one): X New Renewal Modification Form SVM-101 Version 3.99 Page 1 of 4 2. If this application is being submitted as the result of a renewal or modification to an existing permit, list the existing permit number N/A and its issue date (if known) 3. Specify the type of project (check one): Low Density X High Density Redevelop _ General Pernut Other 4. Additional Project Requirements (check applicable blanks): X CAMA Major X Sedimentation/Erosion Control X 404 /401 Permit X NPDES Stormwater Information on required state permits can be obtained by contacting the Customer Service Center at 1-877-623-6748. III. PROJECT U-4MRMATION 1. In the space provided below, summarize how stormwater will be treated. Also attach a detailed narrative (one to two pages) describing stormwater management for the project. The runoff from the built upon area from the first 1.5 inches of rainfall will be collected through inlets in valley curb into an underground pipe network. The stormwater will gravity flow to a chamber from where it will be pumped through a force main to underground perforated pipes located in soils capable of infiltrating the runoff. 2. Stormwater runoff from this project drains to the Lumber River basin. 3. Total Project Area: 48.87 acres 5. How many drainage areas does the project have? 4 4. Project Built Upon Area: 39.12 % 6. Complete the following information for each drainage area. If there are more than two drainage areas in the project, attach an additional sheet with the information for each area provided in the same format as below. Basin Information Drainage Area 100 Drainage Area 200 Receiving Stream Name Intracoastal Waterway Intracoastal Waterway Receiving Stream Class SA SA Drainage Area 425,216 square feet 454,217 square feet Existing Impervious' Area None None Proposed Impervious'Area 213,444 square feet 241,417 square feet % Impervious' Area (total) 50.20% 53.15% Impervious' Surface Area Drainage Area 100 Drainage Area 200 On -site Buildings 114,775 72,500 On -site Streets 76,213 133,600 On -site Parking (drive aprons) 1,395 2,438 On -site Sidewalks 12,079 16,879 Other on -site 8,700 16,000 Off -site None None Total: 213,162 square feet Total: 241,417 square feet *Impervious area is defined as the built upon area including but not limited to, buildings, roads, parking areas, sidewalks, gravel areas, etc. Form SWU-101 Version 3.99 Page 2 of 4 Basin Information Drainage Area 300 Receiving Stream Name Intracoastal Waterway Receiving Stream Class SA Drainage Area 199,086 square feet Existing Impervious' Area None Proposed Impervious* Area 105,000 square feet % Impervious' Area (total) 52.74% Impervious' Surface Area Drainage Area 300 On -site Buildings 33,825 On -site Streets 59,600 On -site Parking 0 On -site Sidewalks 7,885 Other on -site 3,690 Off -site N/A Total: 105,000 Basin Information Drainage Area 400 Receiving Stream Name Intracoastal Waterway Receiving Stream Class SA Drainage Area 630,593 square feet Existing Impervious* Area None Proposed lmpervious'Area 273,100 square feet % Impervious' Area (total) 4331% Impervious' Surface Area Drainage Area 400 On -site Buildings 273,100 On -site Streets 0 On -site Parking 0 On -site Sidewalks 0 Other on -site 0 Off -site N/A Total: 273,100 7. How was the off -site impervious area listed above derived? N/A IV. DEED RESTRICTIONS AND PROTECTIVE COVENANTS The following italicized deed restrictions and protective covenants are required to be recorded for all subdivisions, outparcels and future development prior to the sale of any lot. If lot sizes vary significantly, a table listing each lot number, size and the allowable built -upon area for each lot must be provided as an attachment. 1. The following covenants are intended to ensure ongoing compliance with state stormwater management permit number as issued by the Division of Water Quality. These covenants may not be changed or deleted without the consent of the State. 2. No more than 2500 sq ft for single-family; square feet of any lot shall be covered by structures or impervious materials. see attached for townhomes Impervious materials include asphalt, gravel, concrete, brick, stone, slate or similar material but do not include wood decking or the water surface of swimming pools. 3. Swales shall not be filled in, piped, or altered except as necessary to provide driveway crossings. 4. Built -upon area in excess of the permitted amount requires a state stormwater management permit modification prior to construction. 5. All permitted runoff from outparcels or future development shall be directed into the permitted stormwater control system. These connections to the stormwater control system shall be performed in a manner that maintains the integrity and performance of the system as permitted. By your signature below, you certify that the recorded deed restrictions and protective covenants for this project shall include all the applicable items required above, that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, that the required covenants cannot be changed or deleted without concurrence from the State, and that they will be recorded prior to the sale of any lot. V. SUPPLEMENT FORMS The applicable state stormwater management permit supplement form(s) listed below must be submitted for each BMP specified for this project. Contact the Stormwater and General Permits Unit at (919) 733-5083 for the status and availability of these forms. Form SWU-102 Wet Detention Basin Supplement Form SWU-103 Infiltration Basin Supplement Form SWU-104 Low Density Supplement Form SWU-105 Curb Outlet System Supplement Form SWU-106 Off Site System Supplement Form SWU-107 Underground Infiltration Trench Supplement Form SWU-108 Neuse River Basin Supplement Form SWU-109 Innovative Best Management Practice Supplement Form SWU-101 Version 3.99 Page 3 of 4 2041-38 Waterway Cove NC DENR Division of Water Quality Stormwater Management Permit Application ALLOWABLE IMPERVIOUS AREA FOR EACH TOWNHOME UNIT UNIT # Units Driveways Total 1 1,125 400 1,525 2 1,125 600 1,725 3 1,125 600 1,725 4 1,125 400 1,525 5 1,125 400 1,525 6 1,125 600 1,725 7 1,125 600 1,725 8 1,125 400 1,525 9 1,125 400 1,525 10 1,125 600 1,725 11 - 1,125 600 1,725 12 1,125 400 1,525 13 1,125 400 1,525 14 1,125 600 1,725 15 1,125 600 1,725 16 1,125 400 1,525 17 1,125 400 1,525 18 1,125 600 1,725 19 1,125 600 1,725 20 1,125 400 1,525 21 1,125 400 1,525 22 1,125 600 1,725 23 1,125 400 1,525 24 1,125 400 1,525 25 1,125 600 1,725 26 1,125 400 1,525 27 1,125 400 1,525 28 1,125 600 1,725 29 1,125 400 1,525 30 1,125 400 1,525 31 1,125 600 1,725 32 1,125 400 1,525 33 1,125 400 1,525 34 1,125 600 1,725 35 1,125 400 1,525 36 1,125 400 1,525 37 1,125 600 1,725 38 1,125 400 1,525 39 1,125 400 1,525 40 1,125 600 1,725 41 1,125 600 .1572.5 42 1,125 400 1,525 43 1,12511 400 1,525 44 1,125 600 1,725 45 1,125 600 1,725 46 1,125 400 1,525 47 1,125 400 1,525 48 1,125 �600 1,725 49 1,125 600 1,725 50 1,125 400 1,525 UNIT # Units Driveways Total 51 1,125 400 1,525 52 1,125 600 1,725 53 1,125 600 1,725 54 1,125 400 1,525 55 1,125 400 1,525 56 1,125 600 1,725 57 1,125 600 1,725 58 1,125 400 1,525 59 1,125 400 1,525 60 1,125 600 1,725 61 1,125 600 1,725 62 1,125 400 1,525 63 1,125 400 1,525 64 1,125 600 1,725 65 1,125 600 1,725 66 1,125 400 1,525 67 1,125 400 1,525 68 1,125 600 1,725 69 1,125 600 1,725 70 1,125 400 1,525 71 1,125 400 1,525 72 1,125 600 1,725 73 1,125 600 1,725 74 1,125 400 1,525 75 1,125 400 1,525 76 1,125 600 1,725 77 1,125 400 1,525 78 1,125 400 1,525 79 1,125 600 1,725 80 1,125 600 1,725 81 1,125 400 1,525 82 1,125 400 1,525 83 1,125 600 1,725 84. 1,125 600 1,725 85 1,125 400 1,525 86 1,125 400 •1,525 87 1,125 600 1,725 88 1,1251 400 1,525 89 1,125 400 1,525 90 1,125 600 1,725 91 1,125 600 1,725 92 1,125 400 1,525 93 1,1251 400 1,525 94 1,125 600 1,725 95 1,125 600 1,725- 96 1,125 400 1,525 97 1,125 400 1,525 98 1,125 600 1,725 99 1,125 600 I,725 100 1,125 400 1,525 , TOTAL, 1 112,5001 49,200 161,700 VI. SUBMTTTAL REQUIREMENTS Only complete application packages will be accepted and reviewed by the Division of Water Quality (DWQ). A complete package includes all of the items listed below. The complete application package should be submitted to the appropriate DWQ Regional Office. 1. Please indicate that you have provided the following required information by initialing in the space provided next to each item. • Original and one copy of the Stormwater Management Permit Application Form • One copy of the applicable Supplement Form(s) for each BMP • Permit application processing fee of $420 (payable to NCDENR) • Detailed narrative description of stormwater treatment/management • Two copies of plans and specifications, including: - Development/Project name - Engineer and firm - Legend -North arrow - Scale - Revision number & date - Mean high water line -Dimensioned property/project boundary -Location map with named streets or NCSR numbers - Original contours, proposed contours, spot elevations, finished floor elevations - Details of roads, drainage features, collection systems, and stormwater control measures - Wetlands delineated, or a note on plans that none exist - Existing drainage (including off -site), drainage easements, pipe sizes, runoff calculations -Drainage areas -Vegetated buffers (where required) VII. AGENT AUTHORIZATION If you wish to designate authority to another individual or firm so that they may provide information on your behalf, please complete this section. Designated agent (individual or firm): Reuben S. Jones, III, Branch Office Manager, Milone & MacBroom Inc. Mailing Address: 5511 Capital Center Drive, Suite 106 City: Raleigh Phone: ( 919 ) 854-4373 VIII. APPLICANT'S CERTIFICATION State: NC Fax: ( 919 ) 854-4393 Zip:27606 I, (print or type name of person listed in General Information, item 2) Kyle Corkum certify that the information included on this permit application form is, to the best of my knowledge, correct and that the project will be constructed in conformance with the approved plans, that the required deed restrictions and protective covenants will be recorded, and that the proposed project complies with the requirements of 15A NCAC 21-1.1000. Date: G 12- off Form SWU-101 Version 3.99 Page 4 of 4 In accordance with Title 15 NCAC 2H.1000, the Coastal Stormwater Management Regulations, deed restrictions and protective covenants are required for High Density Residential Subdivisions where lots will be subdivided and sold and runoff will be treated in an engineered stormwater control facility. Deed restrictions and protective covenants are necessary to ensure that the development maintains a built -upon area consistent with the design criteria used to size the stormwater control facility. I. Kyle Corkum , acknowledge, affirm and agree by my signature below, that I will cause the following deed restrictions and covenants to be recorded prior to the sale of any lot: 9. The following covenants are intended to ensure ongoing compliance with State Stormwater Management Permit Number , as issued by the Division of Water Quality under NCAC 2H.1000. 2. The State of North Carolina is made a beneficiary of these covenants to the extent necessary to maintain compliance with the stormwater management permit. 3. These covenants are to run with the land and be binding on all persons and parties claiming under them. 4. The covenants pertaining to stormwater may not be altered or rescinded without the express written consent of the State of North Carolina, Division of Water Quality. 5. Alteration of the drainage as shown on the approved plan may not take place without the concurrence of the Division of Water Quality. 6. The maximum allowable built -upon area per lot is See Attachment C square feet. This allotted amount includes any built -upon area constructed within the lot property boundaries, and that portion of the right-of-way between the front lot line and the edge of the pavement. Built upon area includes, but is not limited to, structures, asphalt, concrete, gravel, brick, stone, slate, coquina and parking areas, but does not include raised, open wood decking, or the water surface of swimming pools. 7. All runoff from the built -upon areas on the lot must drain into the permitted system. This may be accomplished through a variety of means including roof drain gutters which drain to the street, grading the lot to drain toward the street, or grading perimeter swales to collect the lot runoff and direcd g them into a component of the stormwater collection system. Lots that will naturally drain into t e sy tern are not required to provide these additional measures. Sign Date: � 14. T I, A� //in t�r11�1 C/L , a Notary Public in the St of /VV/ZT%� pLC/V�9 , County of do hereby certify that lLylc e1vp-/,/(//A personally appeared before me this the day of Y &q , 20017 , and acknowledge the due execution of the foregoing instrument. Witness my hand and official seal, CAZJV / , J/ SEAL Signature ���"'"`��� UCMy=sum* Commission expires T���/ 2, 20 / It, 2011 ATTACHMENT C 2041-38 WATERWAY COVE Maximum Allowable Built -Upon Area Per Lot Single -Family Lots ...................................... 2,500 square feet Townhome Units #1, 4, 5, 8, 9, 12, 13, 16, 17, 20, 21, 23, 24, 26, 27, 29, 30, 32, 33, 35, 36, 38, 39, 42, 43, 46, 47, 50, 51, 54, 55, 58, 59, 62, 63, 66, 67, 70, 71, 74, 75, 77, 78, 81, 82, 85, 86, 88, 89, 92, 93, 96, 97,100 ............................................. 1,525 square feet #2, 3, 6, 7, 10, 11, 14, 15, 18, 1-9, 22, 25, 28, 31, 34, 37, 40, 41, 44, 45, 48, 49, 52, 53, 56, 57, 60, 61, 64, 65, 68, 69, 72, 73, 76, 79, 80, 83, 84, 87, 90, 91, 94, 95, 98, 99 .................... 1,725 square feet Permit No. _5J07 d5 VY (to be provided by DWO State of North Carolina Department of Environment and Natural Resources Division of Water Quality STORMWATER MANAGEMENT PERMIT APPLICATION FORM UNDERGROUND INFILTRATION TRENCH SUPPLEMENT This form may be photocopied for use as an original DWO Stormwater Management Plan Review: A complete stormwater management plan submittal includes a stormwater management permit application, an underground infiltration trench supplement for each system, design calculations, and plans and specifications showing all stormwater conveyances and system details. I. PROJECT INFORMATION Project Name: Waterway Cove Contact Person: Kyle Corkum Phone Number: (919) 256-1981 For projects with multiple infiltration systems, a supplement form must be completed for each system. This worksheet applies to: Trench INF-100 in Drainage Area WS-100 (from plans) (from Form SWU-101) 11. DESIGN INFORMATION (attach supporting calculations/documentation): Soils Report Summary (based upon an actual field investigation and soil borings) Soil Type WANDO Infiltration Rate 6-8 in/hr or cf/hr/sf (circle appropriate units) SHWT Elevation 28 finsl (Seasonal High Water Table elevation) Trench Design Parameters Design Volume 29,650 c.f. Design Storm 1.5 inch event (1.5 inch event for SA waters, 1 inch event for others) Drawdown Time 1.25* days (* 2"/hr with a factor of safety of 3) Perforated Pipe Size 48" inch diameter Perforated Pipe Length 1.375 ft. No. Observation Wells 5 (may be required on a case -by -case basis) Stone Type (if used) #4 WASHED & CLEANED GRANITE Stone Void Ratio 40% Trench Elevations (in feet mean sea level) 3ottom Elevation 30.0 finsl Storage/Overflow Elevation 35.0 finsl Form SWU-107 Rev 3.99 Page 1 of 4 Trench Dimensions Height 5 ft. Length 275 ft. Width 32 ft. Volume Provided 29,600 cu.ft. I III. REQUIRED ITEMS CHECKLIST The following checklist outlines design requirements per the Stormwater Best Management Practices manual (N.C. Department of Environment, Health and Natural Resources, November 1995) and Administrative Code Section: 15 A NCAC 2H .1008. Initial in the space provided to indicate that the following design requirements have been met and supporting documentation is attached. If the applicant has designated an agent in the Stormwater Management Permit Application Form, the agent may initial below. Attach justification if a requirement has not been met. Applicants Initials 1� S a. System is located 50 feet from class SA waters and 30 feet from other surface waters W b. System is located at least 100 feet from water supply wells. S c. Bottom of system is at least 2 feet above the seasonal high water table. d. Bottom of the system is 3 feet above any bedrock or impervious soil horizon. /[ S e. Off-line system, runoff in excess of the design volume bypasses the system (bypass detail provided). i f. System is designed to draw down the design storage volume to the proposed bottom elevation under seasonal high water conditions within five days based upon infiltration through the bottom only (a hydrogeologic evaluation may be required). S g. Soils have a minimum hydraulic conductivity of 0.52 inches per hour. h. System is not sited on or in fill material or DWQ approval has been obtained. i. Plans ensure that the installed system will meet design specifications (constructed or restored) upon initial operation once the project is complete and the entire drainage area is stabilized. S j. System is sized to take into account the runoff at the ultimate built -out potential from all surfaces draining to the system, including any off -site drainage. 5 k. System is located in a recorded drainage easement for the purposes of operation and maintenance and has recorded access easements to the nearest public right-of-way. S 1. System captures and infiltrates the runoff from the first 1.0 inch of rainfall (1.5 inch event for areas draining to SA waters ). 0140 pro X. in. Drainage area for the device is less than 5 acres. n. A pretreatment device ( filter strip, grassed swale, sediment trap, etc.) is provided. S o. Trench bottom is covered with a layer of clean sand to an average depth of 4 inches. i L p. Sides of the infiltration trench are lined with geotextile fabric. n14 q. Rock used is free of fines (washed stone) and has a large void ratio. r. Side to bottom area ratio is less than 4:1. Form SWU-107 Rev 3.99 Page 2 of 4 s. Observation well(s) are provided (case -by -case basis). s t. Vegetated filter is provided for overflow (50 feet for SA waters, 30 feet for other waters) and detail is shown on plans. einek u. A benchmark for checking sediment accumulation is provided. IV. UNDERGROUND INFILTRATION TRENCH OPERATION AND MAINTENANCE AGREEMENT 1. After every runoff producing rainfall event and at least monthly inspect the bypass/overflow structure for blockage and deterioration and the infiltration system for erosion, trash accumulation, grass cover, and general condition. 2. Repair eroded areas immediately, re -seed as necessary to maintain adequate vegetative cover, mow vegetative cover to maintain a maximum height of six inches, and remove trash and blockages as needed to maintain system performance. 3. Remove accumulated sediment annually or when depth is reduced to 75% of the original design depth. Restore depth to original design depth without over -excavating. Over -excavating may cause the required water table separation to be reduced and may compromise the ability of the system to perform as designed. 4. The water level in any monitoring wells will be recorded after a 1 inch rainfall event and at least once a month. Chronic high water table elevations (within 1 foot of the bottom of the system for a period of three months) shall be reported to DWQ immediately. 5. If DWQ determines that the system is failing, the system will immediately be repaired or replaced to original design specifications. If the system cannot be repaired to perform its design function, other stormwater control devices as allowed by NCAC 2H .1000 must be designed, approved and constructed. 6. Remove accumulated sediment from the infiltration system annually or when depth in the unit is reduced to 75% of the original design depth. The system shall be restored to the original design depth without over - excavating. Over -excavating may cause the required water table separation to be reduced and may compromise the ability of the system to perform as designed. Removed sediment shall be disposed of in an appropriate manner and shall not be handled in a manner that will adversely impact water quality (i.e. stockpiling near a stormwater treatment device or stream, etc.). A benchmark shall be established in the infiltration system. The benchmark will document the original design depth so that accurate sediment accumulation readings can be taken. The measuring device used to determine the depth at the benchmark: shall be such that it will give an accurate depth reading and not readily penetrate into accumulated sediments. When the depth at the benchmark reads , the accumulated sediment shall be removed from the system. Form SWU-107 Rev 3.99 Page 3 of 4 I acknowledge and agree by my signature below that I am responsible for maintaining the stormwater collection system in accordance with the six maintenance procedures listed above. I agree to notify DWQ of any problems with the system or prior to any changes to the system or responsible party. Print Name and Title: Kyle Corkum, Manager Address: Phone: Date: May 22, 2007 Note: Th legally responsible should not be a homeowners association unless more than SQ'0 of the lots have been sold and a resi Sion has been named the president. I, Antoinette Womack , a Notary Public for the State of North Carolina , County of Wake , do hereby certify that Kyle Corkum personally appeared before me this day of May 22 , 2007 , and acknowledge the due execution of the forgoing infiltration basin maintenance requirements. Witness my hand and official seal, "v `e�t' 0.4� �L SEAL My commission expires July . 2011 ANTOINETTE H. WOMACK NOTARY PUBLIC Wake County North Carolina My Commission Expires July 12, 2011 Form SWU 107 Rev 3.99 Page 4 of 4 Permit No. !!� W 8O7o5 q 4 (to be provided by DWQ) State of North Carolina Department of Environment and Natural Resources Division of Water Quality STORMWATER MANAGEMENT PERMIT APPLICATION FORM UNDERGROUND INFILTRATION TRENCH SUPPLEMENT This form may be photocopied for use as an original DWO Stormwater Management Plan Review: A complete stormwater management plan submittal includes a stormwater management permit application, an underground infiltration trench supplement for each system, design calculations, and plans and specifications showing all stormwater conveyances and system details. I. PROJECT INFORMATION Project Name: Waterway Cove Contact Person: Kyle Corkum Phone Number: (919) 256-1981 For projects with multiple infiltration systems, a supplement form must be completed for each system. This worksheet applies to: Trench INF-200 in Drainage Area WS-200 (from plans) (From Form SWU-101) 11. DESIGN INFORMATION (attach supporting calculations/documentation): Soils Report Summary (based upon an actual field investigation and soil borings) Soil Type WANDO Infiltration Rate 6-8 in/hr or cf/hr/sf (circle appropriate units) SHWT Elevation 29 finsl (Seasonal High Water Table elevation) Trench Design Parameters Design Volume 30,185 c.f. Design Storm 1.5 inch event (1.5 inch event for SA waters, 1 inch event for others) Drawdown Time 1.25* days (* 211/hr with a factor of safety of 3) Perforated Pipe Size 4899 inch diameter Perforated Pipe Length 1540 ft. No. Observation Wells _ 7 (may be required on a rase. -by -case basis) Stone Type (if used) #4 WASHED & CLEANED GRANITE Stone Void Ratio 40% Trench Elevations (in feet mean sea level) 3ottom Elevation 31.0 finsl Storage/Overflow Elevation 36.0 firnsl Form SWU-107 Rev 3.99 Page 1 of 4 Trench Dimensions Height 5 ft. Length 220 ft. Width 44 ft. Volume Provided 30,185 cu.ft. I III. REQUIRED ITEMS CHECKLIST The following checklist outlines design requirements per the Stormwater Best Management Practices manual (N.C. Department of Environment, Health and Natural Resources, November 1995) and Administrative Code Section: 15 A NCAC 2H .1008. Initial in the space provided to indicate that the following design requirements have been met and supporting documentation is attached. If the applicant has designated an agent in the Stormwater Management Permit Application Form, the agent may initial below. Attach justification if a requirement has not been met. Applicants Initials S a. System is located 50 feet from class SA waters and 30 feet from other surface waters A S b. System is located at least 100 feet from water supply wells. c. Bottom of system is at least 2 feet above the seasonal high water table. S d. Bottom of the system is 3 feet above any bedrock or impervious soil horizon. e. Off-line system, runoff in excess of the design volume bypasses the system (bypass detail QQ provided). f. System is designed to draw down the design storage volume to the proposed bottom elevation under seasonal high water conditions within five days based upon infiltration through the bottom only (a hydrogeologic evaluation may be required). g. Soils have a minimum hydraulic conductivity of 0.52 inches per hour. S h. System is not sited on or in fill material or DWQ approval has been obtained. r i. Plans ensure that the installed system will meet design specifications (constructed or restored) upon initial operation once the project is complete and the entire drainage area is stabilized. S j. System is sized to take into account the runoff at the ultimate built -out potential from all surfaces draining to the system, including any off -site drainage. ,f k. System is located in a recorded drainage easement for the purposes of operation and maintenance and has recorded access easements to the nearest public right-of-way. y 1. System captures and infiltrates the runoff from the first 1.0 inch of rainfall (1.5 inch event for areas draining to SA waters ). a ram{, in. Drainage area for the device is less than 5 acres. S n. A pretreatment device ( filter strip, grassed swale, sediment trap, etc.) is provided. o. Trench bottom is covered with a layer of clean sand to an average depth of 4 inches. p. Sides of the infiltration trench are lined with geotextile fabric. s q. Rock used is free of fines (washed stone) and has a large void ratio. s r. Side to bottom area ratio is less than 4:1. Form SWU-107 Rev 3.99 Page 2 of NAs. Observation well(s) are provided (case -by -case basis). S t. Vegetated filter is provided for overflow (50 feet for SA waters, 30 feet for other waters) and detail is shown on plans. �t -e kil me. u. A benchmark for checking sediment accumulation is provided. TV. UNDERGROUND INFILTRATION TRENCH OPERATION AND MAINTENANCE AGREEMENT 1. After every runoff producing rainfall event and at least monthly inspect the bypass/overflow structure for blockage and deterioration and the infiltration system for erosion, trash accumulation, grass cover, and general condition. 2. Repair eroded areas immediately, re -seed as necessary to maintain adequate vegetative cover, mow vegetative cover to maintain a maximum height of six inches, and remove trash and blockages as needed to maintain system performance. 3. Remove accumulated sediment annually or when depth is reduced to 75% of the original design depth. Restore depth to original design depth without over -excavating. Over -excavating may cause the required water table separation to be reduced and may compromise the ability of the system to perform as designed. 4. The water level in any monitoring wells will be recorded after a 1 inch rainfall event and at least once a month. Chronic high water table elevations (within 1 foot of the bottom of the system for a period of three months) shall be reported to DWQ immediately. 5. If DWQ determines that the system is failing, the system will immediately be repaired or replaced to original design specifications. If the system cannot be repaired to perform its design function, other stormwater control devices as allowed by NCAC 2H .1000 must be designed, approved and constructed. 6. Remove accumulated sediment from the infiltration system annually or when depth in the unit is reduced to 75% of the original design depth. The system shall be restored to the original design depth without over - excavating. Over -excavating may cause the required water table separation to be reduced and may compromise the ability of the system to perform as designed. Removed sediment shall be disposed of in an appropriate manner and shall not be handled in a manner that will adversely impact water quality (i.e. stockpiling near a stormwater treatment device or stream, etc.). A benchmark shall be established in the infiltration system. The benchmark will document the original design depth so that accurate sediment accumulation readings can be taken. The measuring device used to determine the depth at the benchmark shall be such that it will give an accurate depth reading and not readily penetrate into accumulated sediments. When the depth at the benchmark reads , the accumulated sediment shall be removed from the system. Form SWU-107 Rev 3.99 Page 3 of 4 I acknowledge and agree by my signature below that I am responsible for maintaining the stormwater collection system in accordance with the six maintenance procedures listed above. I agree to notify DWQ of any problems with the system or prior to any changes to the system or responsible party. Print Name and Title: _Kyle Corkun L Manager Address: 5511 Capital Center Drive / Raleigh, NC 27606 Phone: 919 256-1981 Date: May 22, 2007 Sign lepartysiVote: a lll nsibhould not be a homeowners association unless more than 50% of the lots have been sold and a resident of the subdivision has been named the president. I, Antoinette Womack -a Notary Public for the State of North Carolina , Countyof Wake , do hereby certify that Kyle Corkum personally appeared before me this day of May 22 2007 , and acknowledge the due execution of the forgoing infiltration basin maintenance requirements. Witness my hand and official seal, A)'� W - 4w.-_V4- z SEAL My commission expires July,o 1.2011 ANTOINETTE H. WOMACK t NOTARY PUBLIC Wake County North Carolina My Commission Expires July 12, 2011 Form SWIJ 107 Rev 3.99 . Page 4 of 4 Permit No. 5 WS o70s r4 (to be provided by DWQ) State of North Carolina Department of Environment and Natural Resources Division of Water Quality STORMWATER MANAGEMENT PERMIT APPLICATION FORM UNDERGROUND INFILTRATION TRENCH SUPPLEMENT This form may be photocopied for use as an original DWO Stormwater Management Plan Review: A complete stormwater management plan submittal includes a stormwater management permit application, an underground infiltration trench supplement for each system, design calculations, and plans and specifications showing all stormwater conveyances and system details. I. PROJECT INFORMATION Project Name: Waterway Cove Contact Person: Kyle Corkum Phone Number: (919) 256-1981 For projects with multiple infiltration systems, a supplement form must be completed for each system. This worksheet applies to: Trench INF-300 in Drainage Area WS-300 (from plans) (from Form SWU-101) 11. DESIGN INFORMATION (attach supporting calculations/documentation): Soils Report Summary (based upon an actual field investigation and soil borings) Soil Type Infiltration Rate SHWT Elevation Trench Design Parameters Design Volume Design Storm Drawdown Time Perforated Pipe Size Perforated Pipe Length No. Observation Wells Stone Type (if used) Stone Void Ratio WANDO 6-8 in/hr or cf/hr/sf (circle appropriate units) 11.3 fmsl (Seasonal High Water Table elevation) 12,230 c.f. 1.5 inch event (1.5 inch event for SA waters, I inch event for others) 0.7* days (* 2"/hr with a factor of safety of 3) 15" inch diameter 4725 ft. 7 (may be required on a case -by -case basis) #4 WASHED & CLEANED GRANITE 40% Trench Elevations (in feet mean sea level) 3ottom Elevation 13.3 fmsl Storage/Overflow Elevation 16.1 fmsl Form SVVU-107 Rev 3.99 Page 1 of 4 Trench Dimensions Height 2.8 ft. Length 135 ft. I Width 82 ft. Volume Provided 12,230 cu.ft. III. REQUIRED ITEMS CHECKLIST The following checklist outlines design requirements per the Stormwater Best Management Practices manual (N.C. Department of Environment, Health and Natural Resources, November 1995) and Administrative Code Section: 15 A NCAC 2H .1008. Initial in the space provided to indicate that the following design requirements have been met and supporting documentation is attached. If the applicant has designated an agent in the Stormwater Management Permit Application Form, the agent may initial below. Attach justification if a requirement has not been met. Applicants Initials a. System is located 50 feet from class SA waters and 30 feet from other surface waters �{ b. System is located at least 100 feet from water supply wells. �►S c. Bottom of system is at least 2 feet above the seasonal high water table. d. Bottom of the system is 3 feet above any bedrock or impervious soil horizon. e. Off-line system, runoff in excess of the design volume bypasses the system (bypass detail provided). S f. System is designed to draw down the design storage volume to the proposed bottom elevation under seasonal high water conditions within five days based upon infiltration through the bottom only (a hydrogeologic evaluation may be required). S g. Soils have a minimum hydraulic conductivity of 0.52 inches per hour. h. System is not sited on or in fill material or DWQ approval has been obtained. i. Plans ensure that the installed system will meet design specifications (constructed or restored) upon initial operation once the project is complete and the entire drainage area is stabilized. S j. System is sized to take into account the runoff at the ultimate built -out potential from all surfaces draining to the system, including any off -site drainage. S k. System is located in a recorded drainage easement for the purposes of operation and maintenance and has recorded access easements to the nearest public right-of-way. s 1. System captures and infiltrates the runoff from the first 1.0 inch of rainfall (1.5 inch event for areas draining to SA waters ). �Pprox. m. Drainage area for the device is less than 5 acres. n. A pretreatment device ( filter strip, grassed swale, sediment trap, etc.) is provided. o. Trench bottom is covered with a layer of clean sand to an average depth of 4 inches. P. Sides of the infiltration trench are lined with geotextile fabric. q. Rock used is free of fines (washed stone) and has a large void ratio. r. Side to bottom area ratio is less than 4:1. Form SWU-107 Rev 3.99 Page 2 of 4 H s. Observation well(s) are provided (case -by -case basis). S t. Vegetated filter is provided for overflow (50 feet for SA waters, 30 feet for other waters) and detail is shown on plans. .&� u. A benchmark for checking sediment accumulation is provided. IV. UNDERGROUND INFILTRATION TRENCH OPERATION AND MAINTENANCE AGREEMENT 1. After every runoff producing rainfall event and at least monthly inspect the bypass/overflow structure for blockage and deterioration and the infiltration system for erosion, trash accumulation, grass cover, and general condition. 2. Repair eroded areas immediately, re -seed as necessary to maintain adequate vegetative cover, mow vegetative cover to maintain a maximum height of six inches, and remove trash and blockages as needed to maintain system performance. 3. Remove accumulated sediment annually or when depth is reduced to 75% of the original design depth. Restore depth to original design depth without over -excavating. Over -excavating may cause the required water table separation to be reduced and may compromise the ability of the system to perform as designed. 4. The water level in any monitoring wells will be recorded after a 1 inch rainfall event and at least once a month. Chronic high water table elevations (within 1 foot of the bottom of the system for a period of three months) shall be reported to DWQ immediately. 5. If DWQ determines that the system is failing, the system will immediately be repaired or replaced to original design specifications. If the system cannot be repaired to perform its design function, other stormwater control devices as allowed by NCAC 2H .1000 must be designed, approved and constructed. 6. Remove accumulated sediment from the infiltration system annually or when depth in the unit is reduced to 75% of the original design depth. The system shall be restored to the original design depth without over - excavating. Over -excavating may cause the required water table separation to be reduced and may compromise the ability of the system to perform as designed. Removed sediment shall be disposed of in an appropriate manner and shall not be handled in a manner that will adversely impact water quality (i.e. stockpiling near a stormwater treatment device or stream, etc.). A benchmark shall be established in the infiltration system. The benchmark will document the original design depth so that accurate sediment accumulation readings can be taken. The measuring device used to determine the depth at the benchmark shall be such that it will give an accurate depth reading and not readily penetrate into accumulated sediments. When the depth at the benchmark reads, the accumulated sediment shall be removed from the system. Form SWU-107 Rev 3.99 Page 3 of I acknowledge and agree by my signature below that I am responsible for maintaining the stormwater collection system in accordance with the six maintenance procedures listed above. I agree to notify DWQ of any problems with the system or prior to any changes to the system or responsible party. Print Name and Title: Kyle Corkum, Manager Address: 5511 Capital Center Drive I Raleigh. NC 27606 Phone: Si Date: May 22, 2007 Note: ke legally responsibg parry should not be a homeowners association unless more than 50% of the lots have been sold and a resi vision has been named the president. I, Antoinette Womack , a Notary Public for the State of North Carolina , County of Wake , do hereby certify that Kyle Corkum personally appeared before me this day of May 22 2007 , and acknowledge the due execution of the forgoing infiltration basin maintenance requirements. Witness my hand and official seal, SEAL My commission expires ANTOINETTE H. WOMACK NOTARY PUBLIC Wake County North Carolina My Commission Expires July 12, 2011 Form S W U 107 Rev 3.99 , Page 4 of 4 Permit No. Swc 0 7 0 5 4 U (to be provided by DWQ) State of North Carolina Department of Environment and Natural Resources Division of Water Quality STORMWATER MANAGEMENT PERMIT APPLICATION FORM UNDERGROUND INFILTRATION TRENCH SUPPLEMENT This form may be photocopied for use as an original DWO Stormwater Management Plan Review: A complete stormwater management plan submittal includes a stormwater management permit application, an underground infiltration trench supplement for each system, design calculations, and plans and specifications showing all stormwater conveyances and system details. I. PROJECT INFORMATION Project Name: Waterway Cove Contact Person: Kvle Corkum Phone Number: (919) 256-1981 For projects with multiple infiltration systems, a supplement form must be completed for each system. This worksheet applies to: Trenches Type A in Drainage Area 400 (from plans) (from Form SWU-101) II. DESIGN INFORMATION (attach supporting calculations/documentation): Soils Report Summary (based upon an actual field investigation and soil borings) Soil Type WANDO Infiltration Rate 6-8 in/hr or cf/hr/sf (circle appropriate units) SHWT Elevation SEE ATTACHED finsl (Seasonal High Water Table elevation) Trench Design Parameters Design Volume SEE ATTACHED c.f. , Design Storm 1.5 inch event (1.5 inch eventfor SA waters, I inch eventfor others) Drawdown Time 1.6 days Perforated Pipe Size N/A inch diameter Perforated Pipe Length N/A ft. No. Observation Wells N/A (may be required on a case -by -case basis) Stone Type (if used) #4 WASHED & CLEANED GRANITE Stone Void Ratio 40% Trench Elevations (in feet mean sea level) Bottom Elevation SEE ATTACHED finsl Storage/Overflow Elevation SEE ATTACHED fmsl Form SWU-107 Rev 3.99 Page 1 of 4 Trench Dimensions Height 5.58 ft. Length 40 ft. Width 4 ft. Volume Provided 892.86 cu.ft. III. REQUIRED ITEMS CHECKLIST The following checklist outlines design requirements per the Stormwater Best Management Practices manual (N.C. Department of Environment, Health and Natural Resources, November 1995) and Administrative Code Section: 15 A NCAC 2H .1008. Initial in the space provided to indicate that the following design requirements have been met and supporting documentation is attached. If the applicant has designated an agent in the Stormwater Management Permit Application Form, the agent may initial below. Attach justification if a requirement has not been met. Applicants Initials a. System is located 50 feet from class SA waters and 30 feet from other surface waters b. System is located at least 100 feet from water supply wells. c. Bottom of system is at least 2 feet above the seasonal high water table. d. Bottom of the system is 3 feet above any bedrock or impervious soil horizon. e. Off-line system, runoff in excess of the design volume bypasses the system (bypass detail provided). f. System is designed to draw down the design storage volume to the proposed bottom elevation under seasonal high water conditions within five days based upon infiltration through the bottom only (a hydrogeologic evaluation may be required). AS1 g. Soils have a minimum hydraulic conductivity of 0.52 inches per hour. S , h. System is not sited on or in fill material or DWQ approval has been obtained. i. Plans ensure that the installed system will meet design specifications (constructed or restored) upon initial operation once the project is complete and the entire drainage area is stabilized. �S j. System is sized to take into account the runoff at the ultimate built -out potential'from all surfaces draining to the system, including any off -site drainage. S k. System is located in a recorded drainage easement for the purposes of operation and maintenance and has recorded access easements to the nearest public right-of-way. S 1. System captures and infiltrates the runoff from the first 1.0 inch of rainfall 0.5 inch event for areas draining to SA waters ). in. Drainage area for the device is less than 5 acres. n. A pretreatment device ( filter strip, grassed swale, sediment trap, etc.) is provided. o. Trench bottom is covered with a layer of clean sand to an average depth of 4 inches. p. Sides of the infiltration trench are lined with geotextile fabric. q. Rock used is free of fines (washed stone) and has a large void ratio. r. Side to bottom area ratio is less than 4:1. Form SWU 107 Rev 3.99 Page 2 of 4 IV H s. Observation well(s) are provided (case -by -case basis). s t. Vegetated filter is provided for overflow (50 feet for SA waters, 30 feet for other waters) and detail is shown on plans. A-ZA ^&tf u. A benchmark for checking sediment accumulation is provided. IV. UNDERGROUND INFILTRATION TRENCH OPERATION AND MAINTENANCE AGREEMENT 1. After every runoff producing rainfall event and at least monthly inspect the bypass/overflow structure for blockage and deterioration and the infiltration system for erosion, trash accumulation, grass cover, and general condition. 2. Repair eroded areas immediately, re -seed as necessary to maintain adequate vegetative cover, mow vegetative cover to maintain a maximum height of six inches, and remove trash and blockages as needed to maintain system performance. 3. Remove accumulated sediment annually or when depth is reduced to 75% of the original design depth. Restore depth to original design depth without over -excavating. Over -excavating may cause the required water table separation to be reduced and may compromise the ability of the system to perform as designed. 4. The water level in any monitoring wells will be recorded after a 1 inch rainfall event and at least once a month. Chronic high water table elevations (within 1 foot of the bottom of the system for a period of three months) shall be reported to DWQ immediately. 5. If DWQ determines that the system is failing, the system will immediately be repaired or replaced to original design specifications. If the system cannot be repaired to perform its design function, other stormwater control devices as allowed by NCAC 2H .1000 must be designed, approved and constructed. 6. Remove accumulated sediment from the infiltration system annually or when depth in the unit is reduced to 75% of the original design depth. The system shall be restored to the original design depth without over - excavating. Over -excavating may cause the required water table separation to be reduced and may compromise the ability of the system to perform as designed. Removed sediment shall be disposed of in an appropriate manner and shall not be handled in a manner that will adversely impact water quality (i.e. stockpiling near a stormwater treatment device or stream, etc.). A benchmark shall be established in the infiltration system. The benchmark will document the original design depth so that accurate sediment accumulation readings can be taken. The measuring device used to determine the depth at the benchmark shall be such that it will give an accurate depth reading and not readily penetrate into accumulated sediments. When the depth at the benchmark reads, the accumulated sediment shall be removed from the system. Form SWU-107 Rev 3.99 Page 3 of 4 LL W w ¢ d c O O f00� O � Ny 8 N ID I� OI �p p A N pm� m pp spy {Oy spy N Ih N m m m O O O O W O O Q LL J 0 � o N In Y1 N 117 Iq N Yi It1 N N N N Iq N IH In Y; IA N N N IA N N N Ifj It) N N M N IA O O 11 O O O O O C G O O O O O O O O O O O O O O O O O O O G G G O O O O O O O C O O C � p2 E _a N q� e9 n6 m �i tyi ai �i t+i Oi w O a � lV N N N Cj tN�l N N N N lV � N 1[J tV N N N N N N� N N N N N N N N N N N N N tV N N N N N u O J jilfD lmV N O N O N O N O N O N O N O N O N O N N N N N N N N N N N N (Oy N N N N N N N N N N N N N N N N Z O f W AgAR1NNNWf9pi xgiNoR 9 ;''fio#9 9 9 9 A 9R9P;Apses m10 j Ilwl N i9 O tN9 �Ny Cl {Ny l9 1{�y t9 �Wy t+l In t9 1n O! N OJ Y7 t7 mN N �H N Np !V H Pl �N1 tlS �M1 a9 tNy t'! (Ny ['1 N Ol Ypf l'J Ypj� N Iq 1N� N 9 Uf t+01 Np t+ff09 pN O h uy h N pN O pN� N N t7 N t7 u'1 M Y7 t7 N f+1 7 O � O S C Z d LUX v o Ou o g 0 g t�l t7 f�3 l7 th l+l t�f t+l t7 tN�f t�l f�i eel t�1 t+f G C G O C G C G G G C G C O O C C O O G 3 '@� R O S N N 1n 1f1 N N N Yf h If1 1n Yl N N Iq In Yf h 1? 1n W � O 0 o II 0 0 0 o c o c c o 0 0 0 0 0 0 0 0 0 0 0 0 m 7R iR iR � X iAR 7AR �C w 2R :R 2e m d � m �E ui x �f m � M iR X _a J m (p p p p pp p p J O 0A Yf Iq O O G Op O ( O(Vy I OIC� O I OIC� O O O O � Oy ry Ory I OIC� O Ft 'a VO W W IA O O O N ��Wy? N In 0 OJ pU? R pa?� N Iq SR- Ippf�?� In N Iq N ��t p?? N II0� N 0 N mIIn N eq tV A d n m t0 4O m m W W O O N N W W Da IZiJ ._. x ro 0 x O 2 o a I acknowledge and agree by my signature below that I am responsible for maintaining the stormwater collection system in accordance with the six maintenance procedures listed above. I agree to notify DWQ of any problems with the system or prior to any changes to the system or responsible party. Print Name and Title: K_vle Corkum. Manager Address: 5511 Capital Center Drive / Raleigy, NC 27606 Phone: 919 256-1901 Date: May 22, 2007 Signature' Note: The al y responsi party should not be a homeowners association unless more than SO'0 of the lots have been sold and a resident of t e subdivision has been named the president. I, Antoinette Womack , a Notary Public for the State of North Carolina , County of Wake , do hereby certify that Kyle Corkum personally appeared before me this day of May 22 , 2007 , and acknowledge the due execution of the forgoing infiltration basin maintenance requirements. Witness my hand and official seal, 9L� . .4, avfvl'a C41- SEAL My commission expires Jul ,K 2011 ANTOINETTE H. WOMACK NOTARY PUBLIC Wake County North Carolina My Commission Expires July 12, 2011 Form SWU-107 Rev 3.99 Page 4 of 4 Permit No. SWAt`)? OS L) IJ (to be provided by DWQ) State of North Carolina Department of Environment and Natural Resources Division of Water Quality STORMWATER MANAGEMENT PERMIT APPLICATION FORM UNDERGROUND INFILTRATION TRENCH SUPPLEMENT This form may be photocopied for use as an original DWO Stormwater Management Plan Review: A complete stormwater management plan submittal includes a stormwater management permit application, an underground infiltration trench supplement for each system, design calculations, and plans and specifications showing all stormwater conveyances and system details. I. PROJECT INFORMATION Project Name : Waterway Cove Contact Person: Kyle Corkum Phone Number: (919) 256-1981 For projects with multiple infiltration systems, a supplement form must be completed for each system. This worksheet applies to: Trenches Tyne B in Drainage Area 400 (from plans) (from Form SWU-101) II. DESIGN INFORMATION (attach supporting calculations/documentation): Soils Report Summary (based upon an actual field investigation and soil borings) Soil Type WANDO Infiltration Rate 6-8 in/hr or cf/hr/sf (circle appropriate units) SHWT Elevation SEE ATTACHED f nsl (Seasonal High Water Table elevation) Trench Design Parameters Design Volume SEE ATTACHED c.f. Design Storm 1.5 inch event (1.5 inch eventfor SA waters, 1 inch eventfor others) Drawdown Time 1.1 days Perforated Pipe Size N/A inch diameter Perforated Pipe Length N/A ft. No. Observation Wells N/A (may be required on a case -by -case basis) Stone Type (if used) #4 WASHED & CLEANED GRANITE Stone Void Ratio 40% Trench Elevations (in feet mean sea level) Bottom Elevation SEE ATTACHED fmsl Storage/Overflow Elevation SEE ATTACHED fmsl Form SWU 107 Rev 3.99 Page 1 of 4 Trench Dimensions Height 4.34 ft. Length 51 ft. Width 4 ft. Volume Provide 885.36 cu.ft. III. REQUIRED ITEMS CHECKLIST The following checklist outlines design requirements per the Stormwater Best Management Practices manual (N.C. Department of Environment, Health and Natural Resources, November 1995) and Administrative Code Section: 15 A NCAC 2H .1008. Initial in the space provided to indicate that the following design requirements have been met and supporting documentation is attached. If the applicant has designated an agent in the Stormwater Management Permit Application Form, the agent may initial below. Attach justification if a requirement has not been met. Applicants Initials a. System is located 50 feet from class SA waters and 30 feet from other surface waters b. System is located at least 100 feet from water supply wells. c. Bottom of system is at least 2 feet above the seasonal high water table. d. Bottom of the system is 3 feet above any bedrock or impervious soil horizon. e. Off-line system, runoff in excess of the design volume bypasses the system (bypass detail provided). �S f. System is designed to draw down the design storage volume to the proposed bottom elevation under seasonal high water conditions within five days based upon infiltration through the bottom only (a hydrogeologic evaluation may be required). g. Soils have a minimum hydraulic conductivity of 0.52 inches per hour. h. System is not sited on or in fill material or DWQ approval has been obtained. i. Plans ensure that the installed system will meet design specifications (constructed or restored) upon initial operation once the project is complete and the entire drainage area is stabilized. j. System is sized to take into account the runoff at the ultimate built -out potential from all surfaces draining to the system, including any off -site drainage. S k. System is located in a recorded drainage easement for the purposes of operation and maintenance and has recorded access easements to the nearest public right-of-way. S 1. System captures and infiltrates the runoff from the first 1.0 inch of rainfall (1.5 inch event for areas draining to SA waters ). m. Drainage area for the device is less than 5 acres. n. A pretreatment device ( filter strip, grassed swale, sediment trap, etc.) is provided. o. Trench bottom is covered with a layer of clean sand to an average depth of 4 inches. p. Sides of the infiltration trench are lined with geotextile fabric. q. Rock used is free of fines (washed stone) and has a large void ratio. r. Side to bottom area ratio is less than 4:1. Form SWU 107 Rev 3.99 Page 2 of 4 N s. Observation well(s) are provided (case -by -case basis). g t. Vegetated filter is provided for overflow (50 feet for SA waters, 30 feet for other waters) and detail is shown on plans. ,4-u u. A benchmark for checking sediment accumulation is provided. IV. UNDERGROUND INFILTRATION TRENCH OPERATION AND MAINTENANCE AGREEMENT 1. After every runoff producing rainfall event and at least monthly inspect the bypass/overflow structure for blockage and deterioration and the infiltration system for erosion, trash accumulation, grass cover, and general condition. 2. Repair eroded areas immediately, re -seed as necessary to maintain adequate vegetative cover, mow vegetative cover to maintain a maximum height of six inches, and remove trash and blockages as needed to maintain system performance. 3. Remove accumulated sediment annually or when depth is reduced to 75% of the original design depth. Restore depth to original design depth without over -excavating. Over -excavating may cause the required water table separation to be reduced and may compromise the ability of the system to perform as designed. 4. The water level in any monitoring wells will be recorded after a 1 inch rainfall event and at least once a month. Chronic high water table elevations (within 1 foot of the bottom of the system for a period of three months) shall be reported to DWQ immediately. 5. If DWQ determines that the system is failing, the system will immediately be repaired or replaced to original design specifications. If the system cannot be repaired to perform its design function, other stormwater control devices as allowed by NCAC 2H .1000 must be designed, approved and constructed. 6. Remove accumulated sediment from the infiltration system annually or when depth in the unit is reduced to 75% of the original design depth. The system shall be restored to the original design depth without over - excavating. Over -excavating may cause the required water table separation to be reduced and may compromise the ability of the system to perform as designed. Removed sediment shall be disposed of in an appropriate manner and shall not be handled in a manner that will adversely impact water quality (i.e. stockpiling near a stormwater treatment device or stream, etc.). A benchmark shall be established in the infiltration system. The benchmark will document the original design depth so that accurate sediment accumulation readings can be taken. The measuring device used to determine the depth at the benchmark shall be such that it will give an accurate depth reading and not readily penetrate into accumulated sediments. When the depth at the benchmark reads, the accumulated sediment shall be removed from the system. Form SWU-107 Rev 3.99 Page 3 of 4 0 § §3 ' ®S o \ � `2m■■m;§«■■ 7 2 $ƒ ■■7^■`k�§� k � §qk �mmq �� d $$og §RmR�mR§2R @ kcc , ■■§§§§§§§§ c � § ! §2§§§§§§§§ 6 CL% ! §§Q§2&2q22 0 Q § - a��■�■@&e@ d2 § § � �E If � � . I acknowledge and agree by my signature below that I am responsible for maintaining the stormwater collection system in accordance with the six maintenance procedures listed above. I agree to notify DWQ of any problems with the system or prior to any changes to the system or responsible party. Print Name and Title: Kyle Corkum, Manager Address: 5511 Cauital Center Drive / Raleigh_ NC 27606 Phone: Si Date: May 22, 2007 Note: a legally responsib party should not be a homeowners association unless more than 50% of the lots have been sold and a resa u division has been named the president. I, Antoinette Womack , a Notary Public for the State of North Carolina , County of Wake , do hereby certify that Kyle Corkum personally appeared before me this day of May 22 2007 , and acknowledge the due execution of the forgoing infiltration basin maintenance requirements. Witness my hand and official seal � ]D U& �'LQ L vL QC4 G SEAL My commission expires July,t 2011 ANTOINETTE H. WOMACK , NOTARY PUBLIC Wake County North Carolina My Commission Expires July 12, 2011 Form SWU 107 Rev 3.99 Page 4 of 4 Permit No. SWIX o7 n S 414 (to be provided by DWQ) State of North Carolina Department of Environment and Natural Resources Division of Water Quality STORMWATER MANAGEMENT PERMIT APPLICATION FORM UNDERGROUND INFILTRATION TRENCH SUPPLEMENT This form may be photocopied for use as an original DWO Stormwater Management Plan Review: A complete stormwater management plan submittal includes a stormwater management permit application, an underground infiltration trench supplement for each system, design calculations, and plans and specifications showing all stormwater conveyances and system details. I. PROJECT INFORMATION Project Name : Waterway Cove Contact Person: Kyle Corkum Phone Number: (919) 256-1981 For projects with multiple infiltration systems, a supplement form must be completed for each system. This worksheet applies to: Trenches Type C in Drainage Area 400 (from plans) (from Form SWU-101) II. DESIGN INFORMATION (attach supporting calculations/documentation): Soils Report Summary (based upon an actual field investigation and soil borings) Soil Type WANDO Infiltration Rate 6-8 in/hr or cf/hr/sf (circle appropriate units) SHWT Elevation SEE ATTACHED finsl (Seasonal High Water Table elevation) Trench Design Parameters Design Volume SEE ATTACHED c.f. Design Storm 1.5 inch event (1.5 inch eventfor SA waters, I inch eventfor others) Drawdown Time 0.7 days Perforated Pipe Size N/A inch diameter Perforated Pipe Length N/A ft. No. Observation Wells N/A (may be required on a case -by -case basis) Stone Type (if used) #4 WASHED & CLEANED GRANITE Stone Void Ratio 40% Trench Elevations (in feet mean sea level) Bottom Elevation SEE ATTACHED fimsl Storage/Overflow Elevation SEE ATTACHED f msl Form SWU-107 Rev 3.99 Page 1 of 4 Trench Dimensions Height 2.79 ft. Length 70 ft. Width 4 ft. Volume Provided 781 cu.ft. III. REQUIRED ITEMS CHECKLIST The following checklist outlines design requirements per the Stormwater Best Management Practices manual (N.C. Department of Environment, Health and Natural Resources, November 1995) and Administrative Code Section: 15 A NCAC 2H .1008. Initial in the space provided to indicate that the following design requirements have been met and supporting documentation is attached. If the applicant has designated an agent in the Stormwater Management Permit Application Form, the agent may initial below. Attach justification if a requirement has not been met. Applicants Initials a. System is located 50 feet from class SA waters and 30 feet from other surface waters A b. System is located at least 100 feet from water supply wells. S c. Bottom of system is at least 2 feet above the seasonal high water table. S d. Bottom of the system is 3 feet above any bedrock or impervious soil horizon. e. Off-line system, runoff in excess of the design volume bypasses the system (bypass detail provided). S f. System is designed to draw down the design storage volume to the proposed bottom elevation under seasonal high water conditions within five days based upon infiltration through the bottom only (a hydrogeologic evaluation may be required). Q g. Soils have a minimum hydraulic conductivity of 0.52 inches per hour. �1 h. System is not sited on or in fill material or DWQ approval has been obtained. i. Plans ensure that the installed system will meet design specifications (constructed or restored) upon initial operation once the project is complete and the entire drainage area is stabilized. j. System is sized to take into account the runoff at the ultimate built -out potential from all surfaces draining to the system, including any off -site drainage. s k. System is located in a recorded drainage easement for the purposes of operation and maintenance and has recorded access easements to the nearest public right-of-way. S 1. System captures and infiltrates the runoff from the first 1.0 inch of rainfall (1.5 inch event for areas draining to SA waters ). m. Drainage area for the device is less than 5 acres. n. A pretreatment device ( filter strip, grassed swale, sediment trap, etc.) is provided. o. Trench bottom is covered with a layer of clean sand to an average depth of 4 inches. p. Sides of the infiltration trench are lined with geotextile fabric. q. Rock used is free of fines (washed stone) and has a large void ratio. r. Side to bottom area ratio is less than 4:1. Form SWU-107 Rev 3.99 Page 2 of 4 s. Observation well(s) are provided (case -by -case basis). S t. Vegetated filter is provided for overflow (50 feet for SA waters, 30 feet for other waters) and detail is shown on plans. u. A benchmark for checking sediment accumulation is provided. IV. UNDERGROUND INFILTRATION TRENCH OPERATION AND MAINTENANCE AGREEMENT 1. After every runoff producing rainfall event and at least monthly inspect the bypass/overflow structure for blockage and deterioration and the infiltration system for erosion, trash accumulation, grass cover, and general condition. 2. Repair eroded areas immediately, re -seed as necessary to maintain adequate vegetative cover, mow vegetative cover to maintain a maximum height of six inches, and remove trash and blockages as needed to maintain system performance. 3. Remove accumulated sediment annually or when depth is reduced to 75% of the original design depth. Restore depth to original design depth without over -excavating. Over -excavating may cause the required water table separation to be reduced and may compromise the ability of the system to perform as designed. 4. The water level in any monitoring wells will be recorded after a 1 inch rainfall event and at least once a month. Chronic high water table elevations (within 1 foot of the bottom of the system for a period of three months) shall be reported to DWQ immediately. 5. If DWQ determines that the system is failing, the system will immediately be repaired or replaced to original design specifications. If the system cannot be repaired to perform its design function, other stormwater control devices as allowed by NCAC 2H .1000 must be designed, approved and constructed. 6. Remove accumulated sediment from the infiltration system annually or when depth in the unit is reduced to 75% of the original design depth. The system shall be restored to the original design depth without over - excavating. Over -excavating may cause the required water table separation to be reduced and may compromise the ability of the system to perform as designed. Removed sediment shall be disposed of in an appropriate manner and shall not be handled in a manner that will adversely impact water quality (i.e. stockpiling near a stormwater treatment device or stream, etc.). A benchmark shall be established in the infiltration system. The benchmark will document the original design depth so that accurate sediment accumulation readings can be taken. The measuring device used to determine the depth at the benchmark shall be such that it will give an accurate depth reading and not readily penetrate into accumulated sediments. When the depth at the benchmark reads , the accumulated sediment shall be removed from the system. Form SWU-107 Rev 3.99 Page 3 of 4 b§ dk { >� § � ( 2■■ § ® ■■` $2 ! - � § §co § § ! ■r§ § &% !.2§§ § m �2 !§ q ^ 13 ! E Bk ° 2 I acknowledge and agree by my signature below that I am responsible for maintaining the stormwater collection system in accordance with the six maintenance procedures listed above. I agree to notify DWQ of any problems with the system or prior to any changes to the system or responsible party. Print Name and Title: _Kyle Corkum, Manager Address: 5511 Capital Center Drive / Raleigh. NC 27606 Phone: �► (919)256-1981 Date: Mav 22, 2007 Note: he legally respons: a party should not be a homeowners association unless more than 50% of the lots have been sold and a resi e u 'vision has been named the president. I, Antoinette Womack , a Notary Public for the State of North Carolina , County of Wake , do hereby certify that Kyle Corkum personally appeared before me this day of May 22 2007 , and acknowledge the due execution of the forgoing infiltration basin maintenance requirements. Witness my hand and official seal, 4, �' vLAe_4qL i� vr�CA-c I L SFAi - My commission expires July 1 2011 ANTOINETTE H. WOMACK NOTARY PUBLIC Wake County North Carolina My Commission Expires July 12, 2011 Form SWU-107 Rev 3.99 Page 4 of 4 Permit No. SW%b 7 C)S 14W (to be provided by DWQ) State of North Carolina Department of Environment and Natural Resources Division of Water Quality STORMWATER MANAGEMENT PERMIT APPLICATION FORM UNDERGROUND INFILTRATION TRENCH SUPPLEMENT This form may be photocopied for use as an original DWO Stormwater Management Plan Review: A complete stormwater management plan submittal includes a stormwater management permit application, an underground infiltration trench supplement for each system, design calculations, and plans and specifications showing all stormwater conveyances and system details. I. PROJECT INFORMATION Project Name: Waterway Cove Contact Person: Kyle Corkum Phone Number: (919) 256-1981 For projects with multiple infiltration systems, a supplement form must be completed for each system. This worksheet applies to: Trenches Tyne D in Drainage Area 400 (from plans) (from Form SWU-101) II. DESIGN INFORMATION (attach supporting calculations/documentation): Soils Report Summary (based upon an actual field investigation and soil borings) Soil Type WANDO Infiltration Rate 6-8 in/hr or cf/hr/sf (circle appropriate units) SHWT Elevation SEE ATTACHED fmsl (Seasonal High Water Table elevation) Trench Design Parameters Design Volume 453 c.f. Design Storm 1.5 inch event (1.5 inch event for S,4 waters, 1 inch event for others) Drawdown Time 1 days Perforated Pipe Size 6 inch diameter Perforated Pipe Length 20 ft. No. Observation Wells N/A (may be required on a case -by -case basis) Stone Type (if used) #4 WASHED & CLEANED GRANITE Stone Void Ratio 40% Trench Elevations (in feet mean sea level) Bottom Elevation SEE ATTACHED fmsl Storage/Overflow Elevation SEE ATTACHED fmsl Form SWU-107 Rev 3.99 Page 1 of 4 Trench Dimensions Height 4 ft. Length 20 ft. Width 8 ft. Volume Provided 640 cu.ft. III. REQUIRED ITEMS CHECKLIST The following checklist outlines design requirements per the Stormwater Best Management Practices manual (N.C. Department of Environment, Health and Natural Resources, November 1995) and Administrative Code Section: 15 A NCAC 2H .1008. Initial in the space provided to indicate that the following design requirements have been met and supporting documentation is attached. If the applicant has designated an agent in the•Stormwater Management Permit Application Form, the agent may initial below. Attach justification if a requirement has not been met. a. System is located 50 feet from class SA waters and 30 feet from other surface waters b. System is located at least 100 feet from water supply wells. c. Bottom of system is at least 2 feet above the seasonal high water table. d. Bottom of the system is 3 feet above any bedrock or impervious soil horizon. e. Off-line system, runoff in excess of the design volume bypasses the system (bypass detail provided). f. System is designed to draw down the design storage volume to the proposed bottom elevation under seasonal high water conditions within five days based upon infiltration through the bottom only (a hydrogeologic evaluation may be required). g. Soils have a minimum hydraulic conductivity of 0.52 inches per hour. S h. System is not sited on or in fill material or DWQ approval has been obtained. i. Plans ensure that the installed system will meet design specifications (constructed or restored) upon initial operation once the project is complete and the entire drainage area is stabilized. j. System is sized to take into account the runoff at the ultimate built -out potential from all surfaces draining to the system, including any off -site drainage. k. System is located in a recorded drainage easement for the purposes of operation and maintenance and has recorded access easements to the nearest public right-of-way. S 1. System captures and infiltrates the runoff from the first 1.0 inch of rainfall (1.5 inch event for areas draining to SA waters ). m. Drainage area for the device is less than 5 acres. n. A pretreatment device ( filter strip, grassed swale, sediment trap, etc.) is provided. o. Trench bottom is covered with a layer of clean sand to an average depth of 4 inches. p. Sides of the infiltration trench are lined with geotextile fabric. q. Rock used is free of fines (washed stone) and has a large void ratio. r. Side to bottom area ratio is less than 4:1. Form SWU 107 Rev 3.99 Page 2 of 4 s. Observation well(s) are provided (case -by -case basis). s t. Vegetated filter is provided for overflow (50 feet for SA waters, 30 feet for other waters) and detail is shown on plans. u. A benchmark for checking sediment accumulation is provided. IV. UNDERGROUND INFILTRATION TRENCH OPERATION AND MAINTENANCE AGREEMENT 1. After every runoff producing rainfall event and at least monthly inspect the bypass/overflow structure for blockage and deterioration and the infiltration system for erosion, trash accumulation, grass cover, and general condition. 2. Repair eroded areas immediately, re -seed as necessary to maintain adequate vegetative cover, mow vegetative cover to maintain a maximum height of six inches, and remove trash and blockages as needed to maintain system performance. 3. Remove accumulated sediment annually or when depth is reduced to 75% of the original design depth. Restore depth to original design depth without over -excavating. Over -excavating may cause the required water table separation to be reduced and may compromise the ability of the system to perform as designed. 4. The water level in any monitoring wells will be recorded after a 1 inch rainfall event and at least once a month. Chronic high water table elevations (within 1 foot of the bottom of the system for a period of three months) shall be reported to DWQ immediately. 5. If DWQ determines that the system is failing, the system will immediately be repaired or replaced to original design specifications. If the system cannot be repaired to perform its design function, other stormwater control devices as allowed by NCAC 2H .1000 must be designed, approved and constructed. 6. Remove accumulated sediment from the infiltration system annually or when depth in the unit is reduced to 75% of the original design depth. The system shall be restored to the original design depth without over - excavating. Over -excavating may cause the required water table separation to be reduced and may compromise the ability of the system to perform as designed. Removed sediment shall be disposed of in an appropriate manner and shall not be handled in a manner that will adversely impact water quality (i.e. stockpiling near a stormwater treatment device or stream, etc.). A benchmark shall be established in the infiltration system. The benchmark will document the original design depth so that accurate sediment accumulation readings can be taken. The measuring device used to determine the depth at the benclunark shall be such that it will give an accurate depth reading and not readily penetrate into accumulated sediments. When the depth at the benchmark reads , the accumulated sediment shall be removed from the system. Form SWU-107 Rev 3.99 Page 3 of 4 H o mmm��mmmmmm�m�b�mmmmmmmm�dim o a Cr:' a o 0 w 0 v ov 0 W 0 W 0 v 0 0 v ss w w 0 a 0 a 0 a 0 W 0 v a v 0 gg 0 0 0 0 0 �� > 3 > w mmm� w w w r c � v � p m d to v to a in v oo rV m V� M m m � m v r, m v v ca m v to m a m '1 a to ua [O v� m m a m �Ci v a Ln v rl to v E II Q 4 o � a m m mm - eo-- - — - - - - m a - mmm -- - - oao -- -— - �Q m a Q o a o 0 0 0 0 0 0 0 o 0 0 0 0 0 0 o o o c o o 0 o 0 0 0 0 0 o c o 0 0 0 0 0 o c o 0 0 0 0 0 0 o c o `C N lr IU Un w in w r IU r In r 1n r m r m r m r q r m r m r u7 r m r Wn r NU� r r IU r in r U[ r r r r r r m r m r m r U W L W se N N m W m W m W m W m W W S. N m W m W m W N W N N N N N N N N 9 N m W 982 m m W m W O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O 7 Lr � m Q o 0 0 2e 0 3e 0 3E ob 0 o 0 o$ � 0 o 8 aE Cl � 0 � � � � aE 0 a4 0 aE 0 aE 0 aE aE ae ae ae aE aP ae 0 0 0 0 0 0 0 0 0 S. o o 0 0 o 0 g o 0 0 0 0 0 0 0 0 0 o 0 c 0 c 0 o 0 0 0 0 0 0 0 0 0 0 o g g o a ci o o 0 0 0 0 0 0 0 o 0 c 0 o o cQi _ti r r r r r r r r .•- r r r r r r r r r r r r r r r r r r r r r w IT N NNNN"19RR N N N mNNNNmm N N N N N 71,171, r m r r r m r m r m r m r m r m r m r m r m r m r m r r m r r m r m r m r w r 7 m Q NNNNNNNNNNNNNNNNNNNNNNNNNNNNNN m r m r m r m r m r m r m r m r m r m r m r m r m r m r m r m r m r m r m r m r m r m r m r to r r O r m r m r O r m r O J rcrgrorrocorrmrwmCiORgwwwwmaommmrm r r r r O O CO Ol EC Ih fC in a fV C7 V to 6 fG iG A m m fC r O r N O a H o W 0 Oi o OI m O> o Ol o Oi m CD m a0 o aD m I� o m m W m Y o m N o [V 0 0 0 O 0 0 N 0 N 0 ri o ri m V o o m m m FO W r r r r r r r r r r ' W r r r r r r r f0 r m r !. r c0 r m r WJ z 20 Q O N O 1ff o IL1 m Ifj o In o 1p m O m tl' o a m r! o m ; m O o o m o 0 0 0 N fV OO > GC EC 12 m iG V.:cG CC Ol 6 O ri In W W 2 S z m m {p r1 m r1 W 01 N V V' h a p If1 1If a Y] m toIL'1 W tom N f9 m m m Y h m 1� h h m h aD N m m aD pp OD W OD N W f7 W N O H Z J w p a O 3 m 0 z o I acknowledge and agree by my signature below that I am responsible for maintaining the stormwater collection system in accordance with the six maintenance procedures listed above. I agree to notify DWQ of any problems with the system or prior to any changes to the system or responsible party. Print Name and Title: Kyle Corkam, Manarer Address: Phone: Date: May 22, 2007 Note: he legally responsi :bA party should not be a homeowners association unless more than 50% of the lots have been sold and a res vision has been named the president. I, Antoinette Womack , a Notary Public for the State of North Carolina , County of Wake . do hereby certify that Kyle Corkum personally appeared before me this day of May 22 , 2007 , and acknowledge the due execution of the forgoing infiltration basin maintenance requirements. Witness my hand and official seal, vyv\c� G{ l SEAL My commission expires Julv.W 2011 ANTOINETTE H. WOMACK NOTARY PUBLIC Wake County North Carolina My Commission Expires July 12, 2011 Form SWU-107 Rev 3.99 Page 4 of 4 Permit No. y (to be provided by DWQJ State of North Carolina Department of Environment and Natural Resources Division of Water Quality STORMWATER MANAGEMENT PERMIT APPLICATION FORM UNDERGROUND INFILTRATION TRENCH SUPPLEMENT This form may be photocopied for use as an original DWO Stormwater ManaLyement Plan Review: A complete stormwater management plan submittal includes a stormwater management permit application, an underground infiltration trench supplement for each system, design calculations, and plans and specifications showing all stormwater conveyances and system details. I. PROJECT INFORMATION Project Name: Waterway Cove Contact Person: Kyle Corkum Phone Number: (919) 256-1981 For projects with multiple infiltration systems, a supplement form must be completed for each system. This worksheet applies to: Trenches Type E in Drainage Area 400 (from plans) (from Form SWU-101) H. DESIGN INFORMATION (attach supporting calculations/documentation): Soils Report Summary (based upon an actual field investigation and soil borings) Soil Type WANDO Infiltration Rate 6-8 in/hr or cf/hr/sf (circle appropriate units) SHWT Elevation Trench Design Parameters SEE ATTACHED fmsl (Seasonal High Water Table elevation) Design Volume 512 c.f. Design Storm 1.5 inch event (1.5 inch eventfor SA waters, I inch eventfor others) Drawdown Time 1 days Perforated Pipe Size 6 inch diameter Perforated Pipe Length 20 ft. No. Observation Wells N/A (may be required on a case -by -case basis) Stone Type (if used) #4 WASHED & CLEANED GRANITE Stone Void Ratio 40% Trench Elevations (in feet mean sea level) Bottom Elevation SEE ATTACHED fmsl Storage/Overflow Elevation SEE ATTACHED fmsl Form SWU 107 Rev 3.99 Page 1 of 4 Trench Dimensions Height 4 ft. Length 30 ft. Width 8 ft. Volume Provided 960 cu.ft. III. REQUIRED ITEMS CHECKLIST The following checklist outlines design requirements per the Stormwater Best Management Practices manual (N.C. Department of Environment, Health and Natural Resources, November 1995) and Administrative Code Section: 15 A NCAC 211.1008. Initial in the space provided to indicate that the following design requirements have been met and supporting documentation is attached. If the applicant has designated an agent in the Stormwater Management Permit Application Form, the agent may initial below. Attach justification if a requirement has not been met. Applicants Initials a. System is located 50 feet from class SA waters and 30 feet from other surface waters b. System is located at least 100 feet from water supply wells. c. Bottom of system is at least 2 feet above the seasonal high water table. d. Bottom of the system is 3 feet above any bedrock or impervious soil horizon. e. Off-line system, runoff in excess of the design volume bypasses the system (bypass detail provided). S f. System is designed to draw down the design storage volume to the proposed bottom elevation under seasonal high water conditions within five days based upon infiltration through the bottom only (a hydrogeologic evaluation may be required). Aso g. Soils have a minimum hydraulic conductivity of 0.52 inches per hour. h. System is not sited on or in fill material or DWQ approval has been obtained. i. Plans ensure that the installed system will meet design specifications (constructed or restored) upon initial operation once the project is complete and the entire drainage area is stabilized. �15 j. System is sized to take into account the runoff at the ultimate built -out potential from all surfaces draining to the system, including any off -site drainage. S k. System is located in a recorded drainage easement for the purposes of operation and maintenance and has recorded access easements to the nearest public right-of-way. k�1. System captures and infiltrates the runoff from the first 1.0 inch of rainfall (1.5 inch event for areas draining to SA waters ). Asp m. Drainage area for the device is less than 5 acres. n. A pretreatment device ( filter strip, grassed swale, sediment trap, etc.) is provided. o. Trench bottom is covered with a layer of clean sand to an average depth of 4 inches. p. Sides of the infiltration trench are lined with geotextile fabric. q. Rock used is free of fines (washed stone) and has a large void ratio. r. Side to bottom area ratio is less than 4:1. Form SWU-107 Rev 3.99 Page 2 of 4 s. Observation well(s) are provided (case -by -case basis). t. Vegetated filter is provided for overflow (50 feet for SA waters, 30 feet for other waters) and detail is shown on plans. _4U A"O* u. A benchmark for checking sediment accumulation is provided. IV. UNDERGROUND INIFA ,TIaATION TRENCH OPERATION AND MAINTENANCE AGREEMENT 1. After every runoff producing rainfall event and at least monthly inspect the bypass/overflow structure for blockage and deterioration and the infiltration system for erosion, trash accumulation, grass cover, and general condition. 2. Repair eroded areas immediately, re -seed as necessary to maintain adequate vegetative cover, mow vegetative cover to maintain a maximum height of six inches, and remove trash and blockages as needed to maintain system performance. 3. Remove accumulated sediment annually or when depth is reduced to 75% of the original design depth. Restore depth to original design depth without over -excavating. Over -excavating may cause the required water table separation to be reduced and may compromise the ability of the system to perform as designed. 4. The water level in any monitoring wells will be recorded after a 1 inch rainfall event and at least once a month. Chronic high water table elevations (within 1 foot of the bottom of the system for a period of three months) shall be reported to DWQ immediately. 5. If DWQ determines that the system is failing, the system will immediately be repaired or replaced to original design specifications. If the system cannot be repaired to perform its design function, other stormwater control devices as allowed by NCAC 2H .1000 must be designed, approved and constructed. 6. Remove accumulated sedimentt from the infiltration system annually or when depth in the unit is reduced to 75% of the original design depth. The system shall be restored to the original design depth without over - excavating. Over -excavating may cause the required water table separation to be reduced and may compromise the ability of the system to perform as designed. Removed sediment shall be disposed of in an appropriate manner and shall not be handled in a manner that will adversely impact water quality (i.e. stockpiling near a stormwater treatment device or stream, etc.). A benchmark shall be established in the infiltration system. The benchmark will document the original design depth so that accurate sediment accumulation readings can be taken. The measuring device used to determine the depth at the benchmark shall be such that it will give an accurate depth reading and not readily penetrate into accumulated sediments. When the depth at the benchmark reads , the accumulated sediment shall be removed from the system. Form SWU-107 Rev 3.99 Page 3 of 4 m W m W$ �Op �Cp Of �Gp O1 tOp W W fop O1 W W (cp �Cp �Cp �cp tcp top 00 s O t0O s c o0 Oo Q s �Cp m � a > W W W Of Of 01 6f W W W Of t c F � O N N N N N N N N N N N N N O O O O 10 10 10 In O O O O fn O N N LL7 Ip !n O O O O N N N E ti' II w Q «9 :4 41 • o ' 0000fCRCR N N N N In N O 'OOOOOOK. WL'l Wn Wn O O In Wn Wn Wn 0O O N N N N N N N N N N N N C0,4" N N N N 2 w m Q O Q$ 0 0 aa 0 @ 0 0 ss}} 0 0 00 0 0 appa 0 0 Ip O C o C C C O G G O 0 0 C C 0 O G C C C G O O C G O 'C O In NY 0. In In In In In O b Iq LL] In Wn an w N W N Wn In 0 LL9 N N N [� W V S iito O W N W N W H W W I� W IfI W LL] W LL] Of In W IDS W I[7 W I[7 W W 1� 07 N Ol W N W W W W O O G O 0 C C O 0 O 0 0 0 C 06 C O O 0 O C G C O C C G If R' O aEaEInaEae$ O O O O O O O g a�maea�ae�� O O O O O O O m e C. E O O o r O C 0 r C 0 r C 0 r O C 0 r O O r O O r O G 0 r O O 0 r C 0 r O O 0 r O O 0 r O O 0 r O 0 r O 0 r O C o r O g r O g r O O o r O O 0 r O C 0 r O O 0 r O C 0 r O G 0 r O 0 r C 0 J II�n II�D WW�n �II� �II� II�n WW�n In �n II�n II�n WW�n II�n II�n `W- fA N N N N N N N •`� •`I �Oy N N N N N N N N N N WW�D N yIn� N N N N II�n N A A In A A A A A A A m Q W n A Rw A iq R R R A 4 n 9 9 A I R J m r r iD ID r m m r W W W W W Lh W m m W fD W q m t0 r � r ' � r .- O Ol W7f m CC f0 f0 � � N Lh 10 Y] 1G tD n Di O1 r Z O OQ O 0, O W b ai 0 W 0 W u'9 aD 0 m 0 A O m 0 0 N 0 N' 0 0 CV In 0 0 C 0 lV 0 CV 0 M 0 M 0 0 0 n O N F W r Oj O f+ tp O J W � 0 aO Wfi Ir) I[i 0 IO 0 Wri 0 u9 In at 0 V 0 Ol 0 (V 0 0 0 0 o in 0 0 0 0 0 0 0 0 0 Wn n m� r 0 0 w A N 0 w m Cl CD w w 2 A f.+1 O a V LL7 a f N O CQ 1n �p b A O O w m CD In w l'q A {{pp A WW A O c0 f7 co ..pp CG A co O W O co Q? F C9 rD O W J N 0 3 0 Z to W Q m I acknowledge and agree by my signature below that I am responsible for maintaining the stormwater collection system in accordance with the six maintenance procedures listed above. I agree to notify DWQ of any problems with the system or prior to any changes to the system or responsible party. Print Name and Title: Kyle Corkum, Manager Address: 5511 Capital Center Drive / Raleigh, NC 27606 Phone: 919 256-1981 Date: May 22, 2007 Si 1 V Ote: T e4 l�ffd e party should not be a homeowners association unless more than 50% of the lots have been sold and a resident of the subdivision has been named the president. 1, Antoinette Womack , a Notary Public for the State of North Carolina , County of Wake , do hereby certify that Kyle Corkum personally appeared before me this day of May 22 , 2007 , and acknowledge the due execution of the forgoing infiltration basin maintenance requirements. Witness my hand and official seal, av SEAL My commission expires JUly�f 2 1 ANTOINETTE H. WOMACK NOTARY PUBLIC Wake County North Carolina My Commission Expires July 12, 2011 Form SWU-107 Rev 3.99 Page 4 of 4 Engineering, Landscape Architecture and Environmental Science MILONE & MACBROOM® June 27, 2007 Mr. Chris Baker N.C. Department of Environment and Natural Resources Water Quality Section Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, North Carolina 28405 RE: Request for Additional Information Stormwater Project No. SW8070544 Waterway Cove (Brunswick County) Dear Mr. Baker, We received a copy of your request for additional information addressed to Mr. Kyle Corkum of Waterboro Village, LLC, dated June 21, 2007, concerning the above referenced project located on NC Highway 179/904 at SR 1232 within the Shallotte Township. We offer the following responses to each of your requirements and concerns: 1. All plan sheets must have a P.E. seal not just the cover, please correct. Response: Enclosed are two (2) copies of the plan set with each individual sheet signed and sealed, as well as a revised set of the associated calculations signed and sealed. 2. Infiltration trenches INF-100, 200, 300 and trenches type A, B, and C are undersized. It appears from the calculations provided that only the built -upon area was used to determine the runoff. . Schuler's method or a more conservative method must be used to determine stormwater runoff, please correct. Response: The infiltration trenches were sized to capture 100% of the runoff from all impervious surfaces, under the assumption that runoff would not be generated during the first 1.5" of the 25-year storm in areas that were grass or tree covered since the Wando (type -A hydrologic group) combined with the flat slopes of the site would most likely infiltrate the rainfall instantaneously. In further review of our submittal it was determined the incorrect overall watershed sizes as well as total watershed impervious amounts were incorrectly listed on the application (form SWU-101, page 2) Milone & MacBroom, 'Inc., 5511 Capital Center Drive, Suite 106, Raleigh, North Carolina 27606 (919) 854-4373 Fax (919) 854-4393 for watersheds 100, 200, and 300 and has been revised to reflect the corrected square footages as they pertain to the current siteplan. We have re -calculated the runoff generation for all the requested watersheds using the "Simple Method" (which is an acceptable for of runoff volume estimation per NC DENR) as outlined in chapter 3, section 3, subsection 1 (3.3.1) of the "2007 (Draft) NCDENR Stormwater BMP Manual". This method estimates the volume of runoff using the watershed area, percentage of impervious surface, and depth of rainfall using a function derived from historical data of watersheds. Using this method, it was determined that infiltration basins INF-100, 200, and 300 were adequately sized, and actually provided storage volumes exceeding the calculated volume of runoff (see table below). 3.3.1 SIMPLE METHOD V = 3630 * Rd * Rv * A Where: V = Volume of runoff that must be controlled for the design storm (83) Rd = Design storm rainfall depth (in) A = Watershed area (ac) Rv = Runoff coefficient [storm runoff (in)/storm rainfall (in)], unitless Where: Rv = 0.05 +0.9 * Ia Ia = Impervious fraction impervious IMPERVIOUS/ RUNOFF BASIN WATERSHED BUILT UPON NFALL RUNOFF CAPTURE VOLUME WATERSHED !DEPTH VOLUME ID AREA AREA COEFFICIENT REQUIRED PROVIDED S S IN Rv C C DA-100 425,216 213,444 1.5 0.50 26,670 26,950 DA-200 454,217 241,417 1.5 0.53 29,998 30,185 DA-300 1 199,086 1 105,000 1.5 1 0.52 13,057 1 13,230 The "on -lot" trench types (AA & C) were originally sized to provide infiltration capability for twenty -five -hundred square feet (2500 SF) of impervious/built upon area per lot, however, using the "simple method" it was determined the length of trenches would need to be increased to provide adequate storage of runoff generated by the parcel's lawn & treed areas. These revised trench dimensions have been included within the calculations section of the submittal, as well as sheet "SD-1" of the plan set. Type "A" was increased to 40 LF, type "B" was increased to 51 LF, and type "c" was increased to 75 LF to meet the largest lot of the group's volume requirements. Calculations for all basin types (INF-100, 200, and 300 as well as trenches A, B, and C) have been provided for these areas using the simple method. ��� MILONE &MACBROOM 3. No calculations were provided for trench types A,B, CD, and E, please provide calculations. Response: A volume calculation has been provided for each of the trench types. 4. On the application please break out the single family lots and townhomes that will be treated on the individual lots into one separate drainage area for reporting purposes. Response: A fourth designation, 11DA400", has been added to the application to account for the "on -lot" watershed(s). A check for the two -thousand dollar ($2000) re -submittal fee has been included. Thank you for the opportunity to provide the referenced revisions. Please contact us if additional information or clarification is needed to complete the review. Very truly yours, Milone & MacBr000m-, Inc. ��c. -`[ y • j" Reuben S. Jones, III, .E. Branch Office Manager Enclosures ��� MILONE & MACBROOM STORMWATER MANAGEMENT PERMIT APPLICATION REPORT WATERWAY COVE TOWN OF OCEAN ISLE BEACH, BRUNSWICK COUNTY, NORTH CAROLINA May 23, 2007 Revised: June 13, 2007 Revised: June 27, 2007 J, Ae WLJ-U- r 027821 101 6� Prepared for: Waterboro Village, LLC 5511 Capital Center Drive Suite 105 Raleigh, NC 27606 Prepared by: MILONE & MACBROOM, INC. 5511 Capital Center Drive Suite 106 Raleigh, North Carolina 27606 www.miloneandmacbroom.com MMI #2041-38 STORMWATER MANAGEMENT PERMIT APPLICATION REPORT WATERWAY COVE TOWN OF OCEAN ISLE BEACH, R���� BRUNSWICK COUNTY, NORTH CAROLINA MAY 2 5 2007 May 23, 2007 027821 Prepared for: Waterboro Village, LLC 5511 Capital Center Drive Suite 105 Raleigh, NC 27606 Prepared by: MILONE & MACBROOM, INC. 5511 Capital Center Drive Suite 106 Raleigh, North Carolina 27606 www.miloneandmacbroom com MMI #2041-38 Y: �j� MILONE & MACBROOM TABLE OF CONTENTS ON - PLEMENT 3.0 PROJECT NARRATIVE 4.0 MANAGER'S CERTIFICATE AND EXHIBIT "B" DEED RESTRICTION 5.0 MAPS 6.0 SURFACE WATER CLASSIFICATION 7.0 WETLANDS REPORT 8.0 SOILS REPORT 9.0 RAINFALL DATA 10.0 SITE BUILT UPON AREA TABLES 11.0 RUNOFF RATE FOR DESIGN STORM 12.0 STORMWATER PUMP DESIGN DATA 13.0 UNDERGROUND INFILTRATION TRENCH SIZING 3.0 PROJECT NARRATIVE 1.0 PROJECT NARRATIVE Waterboro Village, LLC, retained Milone & MacBroom, Inc. to assist in preparing documents for application for a stormwater management permit. The project is on the landward side of the Intracoastal Waterway (ICW) in the extra -territorial jurisdiction (ETJ) of the Town of Ocean Isle Beach in Brunswick County, North Carolina. The approximately 49 acre forested property is fronting and south of Rte 179/904 and 0.6 miles west of intersection of Rte 179 and 904. It is bounded by Waterway Drive on the west and south. The property is bounded on the east by single family homes. The Parcel Identification Number (PIN) is 243NB001. Access to the development is from Rte 179/904 and Waterway Drive (SR 1232). The proposed subdivision of 133 single-family lots, 100 townhomes, and an amenity center is located in the Lumber River basin. While the property drains to interior freshwater ponds, the surface water will be considered as SA waters due to the proximity to the SA ICW. The project is being developed under the high density approach and will collect and infiltrate runoff from the built -upon -area (BUA) up to the volume from the first 1.5 inches of rainfall from a given storm event. Deed restrictions and protective covenants will be instituted limiting the impervious areas in common areas/right-of-way and on private lots. These instruments will also require grading to direct stormwater runoff to the respective infiltration areas. As presented in sheet EX-1, areas immediately surrounding the existing ponds within the Seasonal High Water Table 2' Boundary line, are not suitable for infiltrating stormwater. Areas outside this line are suitable. As presented in sheet DWQ-1, the stormwater collection system in the right-of-way (R/W) collects run off from the lots and the driveway aprons, sidewalk, and street. The flow is conveyed to a stormwater pump station chamber. When the water reaches a certain level, a pump begins pumping it through a force main to a diversion box. The diversion box (see detail sheet SD-2) directs the first flush into the underground infiltration pipes. When the infiltration chamber is full, the flow re -directs at this box to a by-pass system. The bypass system only accepts flow from this diverter and terminates with a level spreader feeding a 50 foot -long vegetated filter which spills into one ofthe interior ponds. DA-100 and DA-200 share an infiltration trench bypass system. For instances in which the rate of flow to the stormwater pump exceeds the peak for the first 1.5 inches of rainfall depth, a bypass is also provided at the pump. These bypass systems terminate with a level spreader and vegetated filter as the other bypasses do. As presented in sheets DWQ -2 and -3, some of the lots in the project (a lot refers to a single family parcel or a townhome parcel and driveway) are situated so there is an opportunity to infiltrate all of the first 1.5" of runoff from the BUA. Other lots, because of the lack of suitable soil or drainage direction, do not provide that opportunity. Built upon areas for which the run off is treated in the "right-of-way" collection system (pump.to u/g chambers), are designated with a cross hatch. Built upon areas for which the run off is treated "on -lot" are designated with a single hatch. The "on -lot" infiltration for the townhomes assumes all of the runoff from the roof will be collected and directed to the front. It is understood that those structures may therefore require a. special measure such as an interior roof drain. The stormwater collection system will be sized to accept runoff from the "on -lot" areas as well as the "right-of-way" areas. However, the infiltration chambers are sized to hold BUA runoff excluding lots which treat their own. 4.0 MANAGER'S CERTIFICATE AND EXHIBIT "B" DEED RESTRICTION CERTIFICATE OF MANAGER OF WATERBORO VILLAGE MANAGEMENT, LLC Kyle V. Corkum, hereby certify that I am the duly elected, qualified and acting manger of WATERBORO VILLAGE MANAGEMENT, LLC; a limited liability company duly organized and existing under the laws of the State of North Carolina. Purusant to the the Organizational Documents of the LLC the Manager is hereby authorized, on behalf of, in the name of and for the account of LLC to: a. borrow money and/or obtain or continue credit (with or without security), upon such terms and conditions and in such amounts as such officer(s) or position-holder(s) may deem desirable; b. execute and/or endorse all documents necessary or required to evidence or consummate any loan to LLC; c. guarantee the obligations of others; engage in business transactions of any nature and kind and/or enter into any manner of contractual relationships; e. grant a security interest of any kind in, assign, mortgage, or otherwise encumber property, whether real, personal, tangible, intangible and/or mixed (including securities of all types and in whatever form), of LLC as collateral securing payment or performance relative to any loan to or guaranteed by LLC; f. sell, purchase and/or lease real, personal, tangible, intangible, and/or mixed property; and g. conduct all other business on behalf of the LLC. I further certify that the foregoing authority is not limited to the above -identified officer or position - holder of LLC but shall extend to such additional or different individuals as are named as being so authorized in any letter, form or other written or oral notice by any such above -identified officer or position -holder of LLC. I further certify that the provisions herein are in full conformity with the Organizational Documents. Executed as of this 15th day of May, 2007. GG�77 In accordance with Title 15 NCAC 2H.1000, the Coastal Stormwater Management Regulations, deed restrictions and protective covenants are required for High. Density Residential Subdivisions where lots will be subdivided and sold and runoff will be treated in an engineered stormwater control facility. Deed restrictions and protective covenants are necessary to ensure that the development maintains a "built -upon" area consistent with the design criteria used to size the stormwater control facility. I, Kyle Corkum , acknowledge, affirm and agree by my signature below, that I will cause the following deed restrictions and covenants to be recorded prior to the sale of any lot: 1. The following covenants are intended to ensure ongoing compliance with State Stormwater Management Permit Number , as issued by the Division of Water Quality under NCAC 2H.1000. 2. The State of North Carolina is made a beneficiary of these covenants to the extent necessary to maintain compliance with the stormwater management permit. 3. These covenants are to run with the land and be binding on all persons and parties claiming under them. 4. The covenants pertaining to stormwater may not be altered or rescinded without the express written consent of the State of North Carolina, Division of Water Quality. 5. Alteration of the drainage as shown on the approved plan may not take place without the concurrence of the Division of Water Quality. 6. The maximum allowable built -upon area per lot is See Attachment C square feet. This allotted amount includes any built -upon area constructed within the lot property boundaries, and that portion of the right-of-way between the front lot line and the edge of the pavement. Built upon area includes, but is not limited to, structures, asphalt, concrete, gravel, brick, stone, slate, coquina and parking areas, but does not include raised, open wood decking, or the water surface of swimming pools. 7. All runoff from the built -upon areas on the lot must drain into the permitted system. This may be accomplished through a variety of means including roof drain gutters which drain to the street, grading the lot to drain toward the street, or grading perimeter swales to collect the lot runoff and directirlg them into a component of the stormwater collection system. Lots that will naturally drain into the system are not required to provide these additional measures. Signatufe�� Date: '? .1--4 . Q-j pi �J. JlUoln,4cX, , a Notary Public in the State of /10i7 %�h o & Af /G" , County of M)A do hereby certify that 16//G rc�r2personally appeared before me this the day of , 2001 , and acknowledge the due execution of the foregoing instrument. Witness my hand and official seal, � _ ,fLt i / L SEAL Signature ANMNETTE H. WOMACK M Commission expires t-� i 0r ?oil l OwArapu� Y p t '-fir July �2, 2011 ATTACHMENT C 2041-38 WATERWAY COVE Maximum Allowable Built -Upon. Area Per Lot Single -Family Lots ...................................... 2,500 square feet Townhome Units #1, 4, 5, 8, 9, 12, 13, 16, 17, 20, 21, 23, 24, 26, 27, 29, 30, 32, 33, 35, 36, 38, 39, 42, 43, 46, 47, 50, 51, 54, 55, 58, 59, 62, 63, 66, 67, 70, 71, 74, 75, 77, 78, 81, 82, 85, 86, 88, 89, 92, 93, 96, 97,100 ............................................. 1,525 square feet #2, 3, 6, 7, 10, 11, 14, 15, 18, 1.9, 22, 25, 28, 31, 34, 37, 40, 41, 44, 45, 48, 49, 52, 53, 56, 57, 60, 61, 64, 65, 68, 69, 72, 73, 76, 79, 80, 83, 84, 87, 90, 91, 94, 95, 98, 99 .................... 1,725 square feet 5.0 MAPS ,.... c'` ; - - tS � .tiy � f', )' f S s <, .�� � •' . _ Icy'' -8.1 min 1nm On himla "YI � v 0 a41h�tKHr7.1716Hn. :co 4 ry • C 'j RIC • y u�a � �1F3 , p N . _ - - �l' tt .k } t _ i ,r.. •, 1 _ an t1, a. 4 A �A r1 �y, .. Foot 0 Am Lea�IrwBfleetare 'top.C:? ,CAN T; and Environmeaw science WATERWAY COVE Waterhara visage, UC 5511 Capita! renier Drive, Sr,ta 105 th MMOM & MACBROOM Rwelgh. earCoroIIna 2-s06 ��� 5511 Capital Center Drive - Suite f 06 kalw lt, Mirth HATE' INiY E9, �07 SHEET: C•arulina'�606 (91+)18544373 Fax(919)854-439USGS SITE LOCATION MAP 1 of 1 :cy.is.rnil.nncandma<braam.cum SCALE: r r 5000 toot WATERWAY COVE SOILS MAP 6.0 SURFACE WA T ER C; ASSIFICA i LON Report Date: 05112107 North Carolina Waterbod es Listed by Subbasin Records Found: 92 Note: Waterbodies are listed in more than one subbasin if they cross subbasin boundaries. Search Parameters: Subbasin: 03-07-59 Class: Name: Desc: Index#: Name of Stream Description Curr. Class Date Prop. Class Basin Stream Index # Subbasin# 03-0M9 Intracoastal From Cape Fear River Basin SA;HQW 12/01/63 Lumber 15-25 Waterway at Buoy FI R ev. 4 sec 22 to North Carolina -South Carolina State Line, including all sloughs, sounds, inlets and connecting channels Lockwoods Folly From source to mouth of C;Sw 12/01/63 Lumber 15-25-1-(1) River Royal Oak Swamp Red Run From source to Lockwoods C;Sw 12/01/63 Lumber 15-25-1-2 Folly River Boggy Branch From source to Red Run C;Sw 12/01/63 Lumber 15-25-1-2-1 Pinch Gut Creek From source to Lockwoods C;Sw 12/01/63 Lumber 15-25-1-3 Folly River Holden Creek From source to Lockwoods C;Sw 12/01/63 Lumber 15-25-1-4 Folly River Ramshead Br-anrh From source to Lockwoods C;Sw 12/01/63 Lumber 15-25-1-5 Folly River River Swamp From source to Lockwoods C;Sw 12/01/63 Lumber 15-25-1-6 Folly River Midway Branch From source to River Swamp C;Sw 12/01/63 Lumber 15-25-1-6-1 Sarah Hole From source to River Swamp C;Sw 12/01/63 Lumber 15-25-1-6-2 Rattlesnake Branch From source, to River Swamp C;Sw 12/01/63 Lumber 15-25-1-6-3 Middle Swamp From source to River Swamp C;Sw 12/01/63 Lumber 15-25-1-6-4 Bolivia Branch From source to Middle Swamp C;Sw 12/01/63 Lumber 15-25-1-6-4-1 Half Hell Branch From source to Middle Swamp C;Sw. 12/01/63 Lumber 15-25-1-6-4-2 Clark Branch From source to Lockwoods C;Sw 12/01/63 Lumber 15-25-1-7 Folly River Ford Branch From source to Lockwoods C;Sw 12/01/63 Lumber 15-25-1-8 Folly River Nucitt Branch From source to Lockwoods C;Sw 12/01/63 Lumber 15-25-1-9 Folly River Scotts Branch From source to Lockwoods C;Sw 12/01/63 Lumber 15-25-1-10 Folly River Lockwoods Folly From mouth of Royal Oak SC;HQW 08/01/90 Lumber 15-25-1-(11) River Swamp to Brunswick County SR 1200 Page 1 of 5 7.0 WETLANDS REPORT LM(`J LAND MANAGEMENT GROUP iNc. maillop1mEnvironmental Consultants MEMORANDUM To: Troy DeHaven From Ashley Futral Date: 4/23/2007 Re: USACE Wetland Data Package, Routine Wetland Determination- Waterboro Estates Troy DeHaven: Enclosed is a copy of the Wetland Data Package (including maps, data sheets, etc.) for the above referenced site. This information has been submitted to the US Army Corps of Engineers (USACE) for their use in providing a final jurisdictional determination of the delineated wetland boundary. An on -site meeting with the USACE is scheduled for 51312007, Should you have any questions regarding our delineation work, please feel free to contact me either by phone at 910-452-0001 or by email at afutral((Dlm ro4 up.net. Thank you for allowing us to assist you with this project. Thank you, Ashley Futral Staff Scientist encl. www.lmgroup.net • info@lmgroup.net • Phone: 910.452.0001 • Fax: 910.452.0060 3805 Wrightsville Ave., Suite 15, Wilmington, NC 28403 • P.O. Box 2522, Wilmington, NC 28402 Army Corps of Engineers Wetiand Data Package Va4=rbG� I . act Brunswick County Property Owner: William English Jr 235 Manor Blvd Pearl River, NY 10965 Applicant: Troy DeHaven Land Quest Development 5511 Capital Center Drive, Suite 105 Raleigh, NC 27606 Subdivision name: Lot number: Parcel ID: 1819 Waterway Drive Not Applicable L-38 243NBO3405 Directions: From Wilmington take US 17 South towards Brunswick County. Follow through Brunswick County to Ocean Isle Beach Road/NC 904 South. Take a left onto Ocean Isle Beach Road. Take a right at the intersection with Beach Drive. Take a left at Waterway Drive and follow around to the end. Property is adjacent to the AIWW. Nearest water body: AIWW Name of watershed: Lumber 03040207 Coordinates of Site: Latitude: 33.8949 N Longitude: 78.4488 W USGS Quad: Shallotte Total Sze: N1 acre Total Size of Wetlands: see preliminary wetland map for details AGENT AUTHORIZATION FORM TO WHOM IT MAY CONCERN: Uwe, the undersigned, hereby authorize Land Management Group, Inc. to act as our agent in the determination of jurisdictional wetland boundaries on the subject property, "Waterboro", Bnmswick County, NC. By way of this form, Uwe additionally authorize access to the site by representatives of the US Army Corps of Engineers andlor the NC Division of Coastal Management for the purpose of reviewing the flagged wetland boundary and providing a final jurisdictional determination. Any questions regarding the jurisdictional wetland determination should be directed to Land Management Group, Inc. Please provide the following information: Property Address and Parcel ID Number: -rAx 14a P bQ*M tSuE�y+n . Current Property Owner Name: VJiL�t� +rtn ` n1 bt�tSt�r Owner Address & Phone Number: > ass* mykfl t A- �-1," k Red N1oAIV. , ►S1' labs't Please circle Yes or No for the following_ggestions: ItWe are the current owners: Yes We are under contract to purchase the subject property: Yes VW* are under option to purchase the subject property: Yes UWe have no Iegal interest in subject property: Yes (Le. speculative request •- NOTE: Site access will be restricted without notieetantheriratlan by current owner) W'�i.�+r�k E•iabtls�k Print Owner's Name Owner's Signature (not required itunder contract orunder option) 4t1�e�o�o vtittkse ��Rt�t��C3�-�-� Print Applicant's Name �TAUJ &&, B suq�[tt3 Appk'Ltnt's Signature Date Date Detailed Parcel Results Page 1 of 2 Parcel Information Find Adioinina Parcels Find parcels that are within ' 1 FEET of this parcel. (A value of 1 finds adioining parcels.) This data was last updated on March 5, 2007. Click here to create print page with map and tax information. 11 Parcel Information Parcel Number 243NBO3405 Sale Price Account Number Plat Book & Page B: P: Owner Name ENGLISH WILLIAM A JR Legal Description L-38 01 EST PLAT H/306 Owner Mailing Address Acreage 1 Deed Recorded Date M' Owner Mailing Address 2 235 MANOR BLVD Parcel Address 1819 WATERWAY DR City PEARL RIVER State NY Zip Code 110965 Deed Book & Page B:0357 P:0460 Top of Page Close Parcel Information Window Property Record Card Land Value Deferred Value Building Value Total Taxable Value Other Value Top of Page Close Parcel Information Window Building Information Heated Square Feet Exterior Wall Type Year Built Neighborhood Number Number of Bedrooms Municipality Number of Full Baths Fire Tax District Township SHALLOTTE Story Height Exterior Wall Type Top of Page Close Parcel Information Window Date/Time Stamp The data effective date is: ' This map is prepared for the inventory of real property found within this jurisdiction, and is compiled from recorded deeds, plats and other public records and data. Users of this map are hereby notified that the aforementioned public primary information sources should be March 14, 2007 consulted for verification of the information contained on this map. The County assumes no DATA FORM ROUTINE WETLAND DETERMINATION (1987 COE Wetlands Determination Manual) Project! Site: Waterboro Tract Date: March 2007 County: Brunswick Applicant ! Owner: Troy DeHaven: Waterboro Village Management, LLC Investigator:Christian Preziosi State: N.C. Do normal circumstances exist on the site? Yes X No- Community ID: Is the site significantly disturbed (Atypical situation)? Yes No_.X-- Transect ID: Is the area a potential problem area? Yes No .X Plot ID: (explain on reverse if needed) Pt. 1 Wetland VEGETATION Dominant Plant Species Stratum Indicator I Dominant Plant Species Stratum Indicator 1. Spartina alterniflora 2. Spartina patens 3. Borrichia frutescens 4. Iva frutescens 5. Ilex vomitoria 6. Ilex vomitoria 7. Juncus roemeranus 8. Grass OBL Grass FACW Shrub OBL Shrub FACW Tree FAC Shrub FAC Grass OBL 9. 10. 11. 12. 13. 14. 15. 16. Percent of Dominant Species that are OBL, FACW, or FAC excluding FAC-). 100% Remarks: Wetland Vegetation Present Based Upon Greater than 50% of the Plant Specie ar` re not Classified as FAC-OBL in the National List of Plant Species that Occur in Wetlands. Sample plot was taken... HYDROLOGY X Recorded Data (Describe In Remarks): Stream, Lake, or Tide Gauge x Aerial Photographs _ Other No Recorded Data Available Field Observations: Depth of Surface Water: None (in.) Depth to Free Water in Pit: 61, Depth to Saturated Soil: 6" (in.) Remarks: Wetland Hydrology Indicators Primary Indicators: X Inundated Saturated in Upper 12" Water Marks Drift Lines Sediment Deposits Drainage Patterns in Wetlands Secondary Indicators: Oxidized Roots Channels in Upper 12" Water -Stained Leaves Local Soil Survey Data _ FAC-Neutral Test Other (Explain in Remarks) SOILS Map Unit Name (Series and Phase): Wando Drainage Class: excessively drained Taxonomy (Subgroup):ypic Udipsamments Confirm Mapped Type? Yes_ NoX Profile Description: Depth Matrix Colors Mottle Colors Mottle Texture, Concretions, (inches) Horizon (Munsell Moist) (Munsell Moist) Abundance/Contrast Structure. etc. 1-101, A 10YR 4/3 sand 10-181, C 10YR 3/1 sand Hydric Soil Indicators: Histosol _ Concretions _ Histic Epipedon _ High Organic Content in Surface Layer In Sandy Soils Sulfidic Odor Organic Streaking in Sandy Solis Aquic Moisture Regime Listed On Local Hydric Soils List Reducing Conditions Listed on National Hydric Soils List X Gleyed or Low-Chroma Colors X Other (Explain in Remarks) Remarks: Oxidized rhizospheres found in profile. WETLAND DETERMINATION Hydrophytic Vegetation Present? Yes X No Is the Sampling Point Wetland Hydrology Present? Yes X No Within a Wetland? Yes No_ Hydric Soils Present? Yes x No Remarks: Location (describ 1s/iA3pot classified as a wetland based upon the criteria set forth in the 1987 Army Corps of Engineers Wetlands elineation Manual. Investigator: Christian Preziosi Applicant: Troy DeHaven Land Management Group, Inc. Waterboro Village Management, LLC PO Box 2522 ' 5511 Capital Center Drive, Suite 105 Wilmington, NC 28402 Raleigh, NC 27606 DATA FORM ROUTINE WETLAND DETERMINATION (1987 COE Wetlands Determination Manual) Project/ Site: Waterboro Tract I Date: March 2007 Applicant / Owner: Troy DeHaven: Waterboro Village Management, LLC County: Brunswick Investigator: Christian Preziosi I State: N.C. Do normal circumstances exist on the site? Yes X No- Community ID: Is the site significantly disturbed (Atypical situation)? Yes Now Transact ID: Is the area a potential problem area? Yes No •X Plot ID: (explain on reverse if needed) Pt. 2 Upland VEGETATION Dominant Plant Species Stratum Indicator I Dominant Plant Species Stratum Indicator 1. Smilax bona-nox 2. Quercus virginiana 3. Laurifolia 4. Morelia cerifera 5. Ilex vomitoria 6. Spartina patens 7. 8. Vine FAC 9. Tree FACU+ 10. Tree FACW 11. Shrub FAC+ . 12. Shrub FAC 13. Grass FACW 14. 15. 16. Percent of Dominant Species that are OBL, FACW, or FAC excluding FAC-). 83.3% Remarks: Wetland Vegetation Present Based Upon Greater than 50% of the Plant Specie ar re not Classified as FAC-OBL in the National List of Plant Species that Occur in Wetlands. Sample plot was taken... HYDROLOGY Recorded Data (Describe In Remarks): Stream, Lake, or Tide Gauge Aerial Photographs _ Other X No Recorded Data Available Field Observations: Depth of Surface Water: None (in.) Depth to Free Water in Pit: >12" (in.) Depth to Saturated Soil: >12" (in.) Remarks: Wetland Hydrology Indicators Primary Indicators: Inundated _Saturated in Upper 12" _ Water Marks Drift Lines Sediment Deposits Drainage Patterns in Wetlands Secondary Indicators: Oxidized Roots Channels In Upper 12" Water -Stained Leaves Local Soil Survey Data _ FAC-Neutral Test Other (Explain in Remarks) SOILS Map Unit Name (Series and Phase): Wando Drainage Class: excessively drained Taxonomy (Subgroup):Tyoic Udipsamments Confirm Mapped. Type? Yes_ NoX Profile Description: Depth Matrix Colors Mottle Colors Mottle Texture, Concretions, (inches) Horizon (Munsell Moist) (Munsell Moist) Abundance/Contrast Structure. etc. 1-101, A 10YR 3/3 single grain, loose, fine sand 10-1 S" C 10YR 4/5 sand Hydric Soil Indicators: Histosol _ Concretions _ _ Histic Epipedon _ High Organic Content in Surface Layer in Sandy Soils Sulfidic Odor Organic Streaking in Sandy Soils _ _ Aquic Moisture Regime Listed On Local Hydric Soils List _ Reducing Conditions Listed on National Hydric Solis List _ Gieyed or Low-Chroma Colors —Other (Explain in Remarks) Remarks: WETLAND DETERMINATION Hydrophytic Vegetation Present? Yes X No Is the Sampling Point Wetland Hydrology Present? Yes No x Within a Wetland? Yes_ No X Hydric Soils Present?, Yes No X I Remarks: Location (describe) is/no lassifled as a wetland based upon the criteria set forth in the 1987 Army Corps of Engineers Wetlands Delineation Manual. Investigator: Christian Preziosi Applicant: Troy DeHaven Land Management Group, Inc. Waterboro Village Management, LLC PO Box 2522 55111 Capital Center Drive, Suite 105 Wilmington, NC 28402 Raleigh, NC 27606 1179 NW ,� ``. 17 Russtown ,944�� C I<Run � (/,•�s•n1.i` �t 3 Fishing flier *Boundaries are approximate and are—` �rSITE not meant to be absolute. Map Source: North Carolina Atlas & Gazetteer. Pg 86.2003 L°Qo.. Ocean Isle Ocean, Isle Beach FiWng lea � Troy DeHaven Waterboro Village Mangement, LLC LNG Waterboro Tract LAND MANAGEMENT GROUP mc. Brunswick County, NC Environmental Consultants 02-07-032C March 2007 .,mow 4 � �' i £71 SCALE 1" = 1 Mile Figure 1 Vicinity Map f l sJ p i it 01 qL 4y La4 ! 1 1" � `I _ a'� •. i t k ,�, r•S.' Ml.d -_�' �"Y Ce loft 14 r ..,_ : - - • �' _�- T SITE �;....:. �. r - < i \ _rw •+ , ......ems • , , .- r' - r GAFF � � r��.. ^� � ram—°` r • ., � �- LEV # ..,,RCS-. i - _. +( rs,t"' �,.. '.'.+ "' .. f -• s ,_ � .5 t'.. , r _1 1 � ,{ A J r -k ems, - «•� *Boundaries are approximate and area"''` IaSITE not meant to be absolute. Map Source: Shallotte Quadrangle 7.5 minute (topographic) 1990. Troy DeHaven Waterboro Village Mangement, LLC Waterboro Tract Brunswick County, NC 02-07-032C LMG . <. LAND MATAGEMENT GROUP Li , EnWronmentaf Cons✓Rants March 2007 SCALE 1" = 2000' Figure 2 USGS Topgraphic Flap .. ..�-- �.:,� X. rt. ,.......� �:-•- _-•. L._, w_.. .-.. � t-..7' _. 1.,-=�-.... �.'P .�.....:.- --:.. - - ... ...u1^«^4a�e��, ..:'.ur` .l—.av--..�_ ••,'t+ - .. 3., 'f. R a qd-pf V _ 'Ig` ey �iT _i k �y e l.$i ii } ry �✓Iy� �,�F, cH �` ? td - '�.A." < .t Ji 1 - ,fly,. '>•`t ��ki',� r..yY � �{ _ G .a „ip fir•• �1 � �M � .'� � :••M} 'i�:x �'"�s.�+ . , ' n st ixa{ y SITE Ji �, r .a1�� � vt •e�I WaB V. IVY _ .�. .ei, �4 �; �+- ,1.�,.,,,,•.'"�-- f� � ''k� ��,�ra � �t �'+ y 3 � fax z �t"At.}�.�,nsxa Cy`. .�.�'''•- - - F�'.,wi ' �3'~ i 'c• 'f geu'c„r E a1* •4--.' 4. Bd _ x'� -iSy 4 YfM Y ! _ 'd it _ f '�Wt7�'�• - I FF- GWO fS" M k -. , } *h. ♦ - .. f - R $ `"i• rq , 66 .. r,�;.Ky,,.•rts'lry,..r.. .=v.�- y. ,,:,�., ,xSc. M' .x r x < •w 't. .. *Boundaries are approximate and are }' �`�sliE not meant to be absolute. SCALE 1" = 300' Iviap ♦JUUIl;U. IVr-%\�J hull JUIvCy. Troy DeHaven Waterboro Village Mangement, LLC Waterboro Tract Brunswick County, NC 02-07-032C LG Figure 3 ` LAND t3AtiAGL•?,gi_,ti'I GROUT a]ylronc]ar:ral Const:lrnnfs Soils Map March 2007 mom ' ' ! ti f � �nlp •�s i a. r : I.A.lab— r .=��:����a��-�.� �----::.,,...��_ _ �-�,:-;.-_------_�._�._..-�---.__.. ter. r SOILS REPORT god r1ice " O,V 2522 WOnhVot, J NAr &U/4i w 28402 goono,v °X2aa" Vice .°7aa/c 3805 9404 ,xcce 964 9s Wi,62tng&z-, AV 2840.9 February 6, 2007 Troy M. DeHaven Landquest Development 5511 Capital Center Dr. Suite 105 Raleigh, NC 27606 9%wte: 990-1i2-0009 96. NO-452-0050 aacaca. �iar�2acc�a. �*zeG` Reference: Stormwater infiltration study for the proposed Waterboro Development near Ocean Isle, NC. Dear Mr. DeHaven: On Thursday, February 8"' 2007, Land Management Group, Inc. had the pleasure of evaluating the proposed stornowater h-&hration areas at the proposed Waterboro development site along with the supervis obi of NCDENR DWQ. The purpose of the evaluation was to describe the soil'irofile; *antify the depth to the seasonal high water table, using-6 to 9 foot soil auger borings, and to inform the project engineer of any potential limitations of this project. Actual hydraulic conductivity measurements were not taken. Therefore, my report will focus on suggested infiltration rates from the NC DENR DWQ representative. The soils at this site are mapped as Kureb and Wando soil series soils in the Soil Survey of Brunswick County (C7SDA,19W. Actual soil borings confirm the soil to be Wando Series in borings I-14 shown in Appendix A, the locations of the borings are shown in Appendix C. The soil can best be described as deep sands that formed in a series of depositional events. It is expected that these soils will have high infiltration rate in excess of 6-10 in/hr. The seasonal high water table is normally evident by observation of redoximorphic features suggesting past conditions of saturation and reduction. There is evidence of redoxirnorphic features as shallow as 26" within one of the test borings of the proposed infiltration areas. In the other borings within the infiltration areas, the seasonal high water table was frorn 30" to an excess of 108" across the proposed test areas (see complete boring notes in Appendix ,A). No physical water levels were recorded on February 8`h. All recorded depths are from the existing surface as noted in the pit notes. The official published description and physical and chemical data for the Wando soil series are shown in Appendix B for comparison. bne and M FEB 1 6 2007 1g1SJ In summary, LMG has performed site specific evaluation within the stormwater infiltration area. This area has soils that have a seasonal high vrater table that are 24" in boring 4 the other areas that have seasonal high water tables from 30"in borings 3, 1.3 and 14, to an excess of 108" in borings 7, 10 and 11 from the soil surface and an infiltration rate of up to 10" per hour. All notes for installation and limitations to proposed basin areas are mentioned in Appendix A, as per NC DENR representative. Please do not hesitate to contact me if you have any questions with this report. I may be reached at 910-452-0001, 910-471-0505 or at nhowe1I@lmuogp..net . Sincerely, J Nick Howell Environmental Scientist CC: Ruben Jones Appendix A Soil Boring Notes and design Criteria Waterboro Stonnwater Evaluation GFS Test Locations 10/412005 "Seasonal High Water Table: *Infiltration Rate in/hr: Notes as stated by Vincent Lewis 1 50" 8 to 10 2 65" 8 to 10 3 30" 6 to 8 _ 4 26" 6 to 8 5 38" 6 to 8 6 78" a to 10 7 108" 8 to 10 8 78" $ to 10 9 65" 8 to -10 Had to cut off lower leg of basin due to unsuitable soils. 10 108" 8 to 10 11 108" 8 to 10 12 36" 6 to 8 13 30" 1 6 to 8 14 39' 1 6 to 8 * Values for rates and water table depth as stated by Vincent Lewis Appendix C Test Area Map Waterboro Tract Stormwater Evaluation Test Area Map February 13, 2007 NrrI,1\M( 179 EJProposed infiltration Basin Area. as provided to L.M.G. by others, 0 100 200 400 Testing Location Sa Feet 1 "=200' 9.0 RAINFALL DATA Precipitation Frequency Data Server Page 1 of 4 POINT PRECIPITATION /` I FREQUENCY ESTIMATESRY FROM NOAA ATLAS 14 hq"tiin ir� North Carolina 33.898 N 78.484 W 29 feet from "Precipitation -Frequency Atlas of the United States" NOAA Atlas 14, Volume 2, Version 3 G.M. Bonnin, D. Martin, B. Lin, T. Parzybok, M.Yekta, and D. Riley NOAA, National Weather Service, Silver Spring, Maryland, 2004 Extracted: Mon May 14 2007 l Confidence Limits Seasonality Location Maps Other Info. GIS data Maps Help Docs U.S. Map Precipitation Frequency Estimates (inches) ARI* 5 (Fhr][MF2 0120 345610 5 30 60 6 4 4 7 10 hrdayyeammin mn mn mn mn r ayhday day day day 11 day 0.50 0.80 1.00 1.38 1.72 2.05 2.21 2.70 3.17 3.68 4.29 .80 5.52 6.23 8.37 10.39 12.95 15.55 0 0.59 0.95 1.20 ].65 2.07 9 2.68 666 7.47 9.97 12.33 15.30 18.33 0 0.69 1 1. ] 0 1.40 1.99 2.54 3.13 3.3 8 4 =F91 5. 77 ED 7.33 8.37 9.23 12.12 14.75 18.07 21.39 10 0.77 1.24 1.56 2.26 2.95 3.69 4.03 4.95 5.88 6.89 7.91 8.63 9.77 10.68 13.88 16.68 20.27 23.78 0.87 1.39 1.76 2.60 3.47 .46 4.92 6.08 7.27 8- 9.76 10.53 11.79 12.73 16.34 19.32 23.25 26.94 I25 F-so-_10.95 1.S1 1.91 2.88 3.90 5.12 5.72 7.07 8.51 10.05 11.37 12.14 13.47 14.44 18.34 21.43 25.59 29.38 [ Text version of table "These precipitation frequency estimates are based an a partial duration series. ARI is the Average Recurrence Interval. Please refer to the komwiakm for more information. NOTE: Formatting forces estimates near zero to appear as zero. Partial duration based Point Precipitation Frequenoy Estimates Versions 3 33.898 N 78.484 W 29 4t c Average Recurrence Interval (years) Duration 5-min 4 8 - h r -x- 30-day 10-min 3-hr it- 4-day - 15-min -+- .-!-r-•^- 7-day -e- 60-day -*- `Q- 11) • ti I2-hr t 10-day -+- 60-min 24-hr -r}- 17 A /. nr Precipitation Frequency Data Server Page 2 of 4 Fi Partial duration based Point Precipitation Frequency Estimates Versions 3 33.898 M 78.484 N 29 ft C C C L C C E L L L L L L L L L 71 a T T T T Zh 71 71 � I t t M M t L .0 S Z N N W (aN N M do ID T E £ E E E E 0 I I I I I r I I I -5 'O -0 'C -0 T.0 a V I I I I I 1 Cu M * tie GD N DD 't ID GD I 1 I 1 I I 1 I I 1 In CoIn M M 0 ou M V M ItIn A J.a7 M m . 6 -' M W J+ Duration - - fU M a %a Mon May 14 15:12936 2007 Average Recurrence Interval (Mears) 2 -e- lea - 5 -+- _ 0 0- 10 -e- 500 t .25- 1000 -E- Confidence Limits - * Upper bound of the 90% confidence interval 711 Precipitation Frequency Estimates (inches) 4 7 10 20 30 45 60 15 30 60 120 3 6 12 24 Mhr ARI 5 10E-1 (years) min ]mn nun min m►n nun hr hr hr hr day day day day day day day 1� 0.54 0.87 1.08 1.49 1.85 2.24 2.43 2.98 3.53 .07 .74 5.24 5.99 6.72 8.95 11.06 13.74 16.42 0.64 1.03 1.29 1.79 2.25 2.72 2.96 3.63 .29 4.95 5.75 6.32 7.22 8.05 10.67 13.14 16.24 19.36 0 10 0.75 0.83 1.19 1.33 1.51 2.15 2.75 3.42 3.73 4.59 5.47 6.39 7.36 8.00 9.06 9.95 12.97 15.72 19.18 22.58 1.69 2.44 3.18 .03 .43 5.46 6.54 7.62 8.74 9.41 10.58 11.51 14.83 17.77 21.51 25.09 25 50 0.94 1.02 1.50 1.63 1.90 2.06 .8l .10 3.74 .20 .86 5.41 6.69 8.07 9.47 10.79 11.48 12.77 13.73 17.47 20.59124.69 28.46 5.58 6.28 7.78 9.44 11.10 12.58 13.26 14.61 15.59 19.64 22.88 "27.'21 31.07 100 1.I0 1.75 2.22 .40 .68 6.33 7.21 8.96 10.94 12.93 14.59 15.22 16.60 17.57 21.95 25.21 29.79 33.71 200 1.19 1.88 2.37 .69 5.18 7.15 8.22 10.27 12.62 15.00 16.86 17.40 18.79 19.75 24.41 27.64 32.47 36.35 500 T.29 2.04 2.57 .09 5.88 8.33 9.75 12.24 15.17 18.20 20.30 20.75 22.02 22.92 27.95 31.07 36.17 39.93 1000 1.39 2.18 2.74 .43 6.47 9.36 11.11 14.00 17.43 21.05 23.34 23.68 24.77 25.61 30.86 33.81 39.11 2.73 *The upper bound of the confidence interval at 90% confidence level is the value which 5% of the simulated quantile values for a given frequency are greater than. "These precipitation frequency estimates are based on a partial duration series. ARI 6 the Average Recurrence Interval. Please refer to the documentation for more information. NOTE: Formatting prevents estimates near zero to appear as zero. * Lower bound of the 90% confidence interval Precipitation Frequency Estimates (inches) ARI (years) 5 min 10 15 min min 30 min 66 min 120 min 3 hr 6 12 � hr 11 24 hr 48 hr 11 4 day 11 7 day 11 10 20 day day 11 30 day 45 day 60 day F1 0.47 0.75 0.93 1.28 1.59 1.89 2.03 2.47 2.88 3.35 3.92 4.42 5.12 5.81 7.84 9.77 12.21 14.72 0 0.55 00.64 0.88 1.11 1.C2 1.29 1.53 1.92 2.29 2.45 3.00 3.48 .07 .75 5.34 6.18 6.96 9.34 11.60 14.44 17.34 n2.35 2.88 3.09 3.78 4.43 5.24 6.07 6.74 7.74 8.57 11.35 i3.86 i7.G4 20.20 10 0.71 1.14 1.44 2.09 2.72 3 39 3.66 4.49 5.29 6.25 7.18 7.91 9.01 9.89 12.96 15.64 19.07 22.42 25 0.80 1.27 1.61 2.39 3.19 .07 4.45 5.47 6.49 7.72 8.79 9.58 10.81 1I.75 15.19 18.05 21.81 25.33 Precipitation Frequency Data Server Page 3 of 4 50 0.87 ].38 1.75 2.63 3.57 .65 5.14 J16.33 7.54 8.96 10.15 10.97 12.27 13.23 16.96 ]9.93 23.90 27.53 100 0.93 1.48 1.87 2.87 3.95 5.25 5.86 7.23 8.67 10.33 11.62 12.45 13.81 14.78 18.77 21.82 26.00 29.68 Z00 0.99 1.57 1.99 3.09 4.34 5.88 6.63 8.21 9.91 11.82 13.22 14.04 15.43 16.41 20.65 23.72 28.08 31.78 500 ].07 1.70 2.13 3.40 .87 6.77 7.75 9.65 11.73 14.01 15.57 16.36 17.71 18.67 23.19 6.25 30.84 34.50 1000 1.14 1.79 .25 3.64 531 7.54 8.72 10.90 13.31 15.87 17.54 18.30 19.56 20.47 25.20 8.20 32.95 36.55 wwmenoo nnm va er a umn ... a revei u we vaue wwun ovn or me simuiareu quanuie vamas Tor a given Trequency are rese man. "These precipitation frequency estimates are based on a partial duration maxima series ARI is the Average Recurrence Interval. Please refer to the documentation for more information. NOTE: Formatting prevents estimates near zero to appear as zero. Maps - 178"'W 110-W 1(7 -w 9th Will 7R . A-W 7A _ ii` w Other Maps/Photographs - 7A.4"W 70Y W +� These maps were produced using a direct map request from the U.S. Census Bureau Maooino and Cartooraohic Resources Tiger Mao Server. Please read dUc lair er for more information. <r� t '..f LEGEND kve a= a -� State - Connector Beach County Stream " v Indian Resv Military Area Lake/PondlOcean National Park --- Street Other Park - Expressway City - H I ghway o�- County 6 8 mi Scale 1:228583 2 6 11 kk ? *average --true scale depends on monitorr esolution a _C1. r: View USGS digital orthophoto quadrangle (DOQ)covering this location from TerraServer; USGS Aerial Photograph may also be available from this site. A DOQ is a computer -generated image of an aerial photograph in which image displacement caused by terrain relief and camera tilts has been removed. It combines the image characteristics of a photograph with the geometric qualities of a map. Visit the 1L Sr$. for more information. Watershed/Stream Flow Information - Eind the Watershed for this location using the U.S. Environmental Protection Agency's site. Climate Data Sources - Precipitation frequency results are based on data from a variety of sources, but largely NCDC. The following links provide general information about observing sites in the area, regardless of if their data was used in this study. For detailed information about the stations used in this study, Precipitation Frequency Data Server Page 4 of 4 please refer to our documentation. Using the National Climatic Data Center's (NCDC) station search engine, locate other climate stations within: +/-30 minutes ...OR... 1 +/-1 degree I of this location (33.898/-78.484). Digital ASCII data can be obtained directly from NCDC. Hydrometeorological Design Studies Center DOC/NOAA/National Weather Service 1325 East-West Highway Silver Spring, MD 20910 (301) 713-1669 Questions?: HDSC.Oueslionsrionoaaaoy Disclaimer 10.0 SITE BUILT UPON AREAS TABLES R It .t--i O O rl ��,, N N •--i v1 U'J N 00 rl M N F O F .. O � w w 00 M N y V] v�•� dd0 d Ow cu .. �o*v, O V� O O\ o O, vi � M w � 3W � _M O O en N as en en�' $ z PC In N w �O a a c en rn F N `'^ F O it d F d �> w F � A M h l h O N O 0 m a en d N O M 1' .-- S e [- ~n. $ b O o F z ^Q�]yj p ,•, -- i' M M �v $ p N O •� to g y O M M � E� O F Obi .N� N 0.4 to F 0 d w a z "n"'�"I�""�intnW)W)v,�"Iv,'nV,")W,W)v,wltnwlviW)�-,� o 0 N N N N N N N N N N N N N N N N N N N N N N N N N N N N O O tri � �n [ v'� tei In [ t v'i in t V L �n l t v', h t l �n �O M O O O O O O O O O O O O O O O O O O O (M O O O O O O O O O O O O O O O O O O O Cl O O O O O O O O O O O O O O O O O O ++ 'IT %oItil 1.0I'c:1,1*ko�a�1:T110V" It\10IC 110Nr 0 vI'DI'od-�� n ' N O L F A O� LninL,Lntnhtntn in...Wh v,tn WI) tnVttnW)kc)Nv,W)W)kn ', O N N N N N N N N N N N N N N N N cV cV cV cV N N N ch N N N N O �, • ,-+ .-i .--i r-i --i .--� .--i --� .-+ ,--� .--� ti r-� .--i .--� --� ti ,--� .--i .--i ti .--i ,--� ti .--i r-i .--i ,-i a--+ F M to �D M to tiz t- to \O t` oo O\ O N M to �obw F 00 00 00 00 00 00 00 00 ON o� o, b N N N N N N N N N N N N N N N N N N N N N N N N N N N N O y vi Vi rnln� Vn t^ n vn t1i r% r` vn n r- rn n Wi rw t w Vn Vn t w t nt1i V^ t w rn� F W 0 0 0 0 0 0 0 0 Co o 0 a)0 o 0 0 o O 0 0 0 0 0 o 0 O o o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 a A O kn kn kn to tn v� . . . . . . . h to vi kn kn W to V kn N N N N N N N N N N N N N N N N N N N N N N N N N N N N �y to \D I- 00 \ O .-•i N M et to m t- 00 0\ O N M kn %0 t- 00 0� O r+ N z M M M M M le IRr le eF It v v et et "tr to to to to to M to to to to �o \D %C O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O CD O O CD CD O O O O O O O O CD O r.+ . t V1 ,!'1 V'1 to V'1 Vl Lq V) V7 V) V1 V1 In V) In Vl Vl N V7 Vl V'1 V'1 to N N N N N N N N N N N N N N N N N N N N N N N N NNN N N N N N N N C4 .41 00 co t- 00� 01 O N I M v to �z t- 00 O, O Ty N I M to \O t- 00 C1 O '^1 N M M "o t- 00 � O rl ti N "o\oIct-t-t-t-t-rrt-t-00000021 0000000000ONIV o O,ONN N 0 0 0 0 I 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O O O O O O O O O O O O O O O O O O C O O O O O O O O O O O O O O O a` N N N N N N N N N N N N N N N N N u. N �... N N _ N N N N N N N N N N N N N N N N N N �. - . N M V M 00 Q1 "In V to \0 t- 00 0% O to t- +� '� +-i rl ,-•� N N N N N N N N N N M to to to to to \O ID \Z %.o �o 110 2041-38 Waterway Cove NC DENR Division of Water Quality Stormwater Management Permit Application ALLOWABLE IMPERVIOUS AREA FOR EACH TOWNHOME UNIT UNIT # Units 1 1,125 Driveways Total 1,525 400 2 1,125 600 1,725 3 1,125 600 1,725 4 19 1,125 400 1,525 5 1,125 400 1,525 6 1,125 600 1,725 7 1,125 600 1,725 8 1,125 400 1,525 9 1,125 400 1,525 10 1,125 600 1,725 11 1,125 600 1,725 12 1,125 400 1,525 13 1,125 400 1,525 14 1,125 600 1,725 15 1,125 600 1,725 16 1,125 400 1,525 17 1,125 400 1,525 18 1,125 600 1,725 19 1,125 600 1,725 20 1,125 400 1,525 21 1,125 400 1,525 22 1,125 600 1,725 23 1,125 400 1,525 24 1,125 400 1,525 25 1,125 600 1,725 26 1,125 400 1,525 27 1,125 400 1,525 28 1,125 600 1,725 29 1,125 400 1,525 30 1,125 400 1,525 31 1,125 600 1,725 32 1,125 400 1,525 33 1,125 400 1,525 34 1,125 600 1,725 35 1,125 400 1,525 36 1,125 400 1,525 37 1,125 600 1,725 38 1,125 400 1,525 39 1,125 400 1,525 40 1,125 600 1,725 41 1,125 600 1,725 42 1,125 400 1,525 43 1,125 400 1,525 44 1,125 600 1,725 45 1,125 600 1,725 46 1,125 400 1,525 47 4 1,125 400 1,525 48 1,125 600 1,725 49 1,125 600 1,725 50 1,125 400 1,525 UNIT # Units Driveways Total 51 1,125 400 1,525 52 1,125 600 1,725 53 1,125 600 1,725 54 1,125 400 1,525 55 1,125 400 1,525 56 1,125 600 1,725 57 1,125 600 1,725 58. 1 1,125 400 1,525 59 1,125 400 1,525 60 1,125 600 1,725 61 1,125 600 1,725 62 1,125 400 1,525 63 1,125 400 1,525 64 1,125 600 1,725 65 1,125 600 1,725 66 1,125 400 1,525 67 1,125 400 1,525 68 1,125 600 1,725 69 1,125 600 1,725 70 1,125 400 1,525 71 1,125 400 1,525 72 1,125 600 1,725 73 1,125 600 1,725 74 1,125 400 1,525 75 1,125 400 1,525 76 1,125 600 1,725 77 1,125 400 1,525 78 1,125 400 1,525 79 1,125 600 1,725 80 1,125 600 1,725 81 1,125 400 1,525 82 1,125 400 1,525 83 1,125 600 1725 84 1,125 600 1,725 85 1,125 400 1,525 86 1,125 400 1,525 87 J 1,125 600 1,725 88 1,125 400 1,525 89 1,125 400 1,525 90 1,125 600 1,725 91 11125 600 1,725 92 1,125 400 1,525 93 ti 1,125 400 1,525 94 1,125 600 1,725 95 1,125 600 1,725 96 ' 1,125 400 1,525 97 1,125 400 1,525 98 .1,125 600 1,725 99 1,125 600 1,725 100 1.1251 400 1,525 TOTAL N 112,5001 49,2001 161,700 L LG0 RUNOFF RATE FOR DESIGN STORM Hydrograph Plot Hydraflow Hydrographs by Intelisolve Hyd. No. 1 100 flow to ps 1.5 inch Hydrograph type = SCS Runoff Storm frequency = 25 yrs Drainage area = 4.900 ac Basin Slope = 1.5 % Tc method = USER Total precip. = 8.98 in Storm duration = 24 hrs Wednesday, May 23 2007, 4:23 AM Peak discharge = 31.37 cfs Time interval = 5 min Curve number = 100 Hydraulic length = 1500 ft Time of conc. (Tc) = 10.00 min Distribution = Type III Shape factor = 484 Incremental Rainfall Precipitation Precip (in) Hyd. No. 1 : 100 flow to ps 1.5 inch - 25 Yr 1.00 0.90 0.80 0.70 0.60 0.50 t 0.40 0.30 I 0.20 i i 0.10 0.00 0.0 2.5 5.0 7.5 Type III Design Storm Hydrograph Volume = 149,744 cuft Precip (in) 1.00 0.90 0.80 0.70 0.60 0.50 0.40 0.30 0.20 0.10 0.00 10.0 12.5 15.0 17.5 20.0 22.5 25.0 Time (hrs) DA-100 Precipitation at Cummulative Cummulative Peak Runoff Hour Mark Last 5 min. of hour Precipitation for Hour Precipitation for Storm cfs 1 0.0075 0.09 0.09 2 0.0075 0.09 0.18 3 0.0086 0.1032 0.2832 4 0.0097 0.1164 0.3996 5 0.0108 0.1296 0.5292 6 0.0119 0.1428 0.672 7 0.0156 0.1872 0.8592 8 0.0193 0.2316 1.0908 9 0.0277 0.3324 1.4232 9.25 0.0299 0.0897 1.5129 1.61 Hydrograph Plot Hydraflow Hydrographs by Intelisolve Hyd. No. 1 100 flow to ps 1.5 inch Hydrograph type = SCS Runoff Storm frequency = 25 yrs Drainage area = 4.900 ac Basin Slope = 1.5 % Tc method = USER Total precip. = 8.98 in Storm duration = 24 hrs Q (cfs) 35.00 30.00 25.00 20.00 15.00 10.00 5.00 l.6 0.00 0 3 5 Hyd No. 1 100 flow to ps 1.5 inch Hyd. No. 1 -- 25 Yr Wednesday, May 23 2007, 4:23 AM Peak discharge = 31.37 cfs Time interval = 5 min Curve number = 100 Hydraulic length = 1500 ft Time of conc. (Tc) = 10.00 min Distribution = Type III Shape factor = 484 Hydrograph Volume = 149,744 cuft Q (cfs) 35.00 30.00 25.00 20.00 15.00 10.00 IWOR - I 1 0.00 8 4 Zs 10 13 15 18 20 23 25 Time (hrs) e- 0 0 N n �' o y- o� (D a EL (L) 7 o U O ++ C U N ^ N O s N O U N N E �J r E O .. O N O U N ....t aJ O N O ii N N N O L O Q O = O Er U R : p O % V► N m O N 7 c N U O 2) f0 s o t0 E t, D 00 O L r+ (D Q7 (n -O .N "(n L n = �' " coo - 3 w E a� O cu v O V = CD5 Eo ma's. OeN 0-0 U0 O M Y cu N (n O .O d C � U E N w cc (V U) ch LuxB v �I C m xiLu s C. J 0eqrCDmI>oI.LO CL R v = O d M N N N M N _Q N C. 3 C1 .4PMMirlcMNMM Oc = C ID CAI Eri M N It) = P P P o r Cd 6 Cd N N O 0 0 0 0 L v r r r r O � Y t�ao r M 0 >A r co r M I- O tD M O to M M N N r r 0 0 CY N o 0 0 0 0 0 0 0 0 C 00000Nd MNr r d C. E C CD L a Hydrograph 'Plot Hydrafow Hydrographs by Intelisolve I Hyd. No. 1 200 flow to ps 1.5 inch Hydrograph type = SCS Runoff Storm frequency = 25 yrs Drainage area = 5.500 ac Basin Slope = 1.5 % Tc method = USER Total precip. = 8.98 in Storm duration = 24 hrs Wednesday, May 23 2007, 4:45 AM Peak discharge = 35.21 cfs Time interval = 5 min Curve number = 100 Hydraulic length = 1500 ft Time of conc. (Tc) = 10.00 min Distribution = Type III Shape factor = 484 Incremental Rainfall Precipitation Precip (in) Hyd. No. 1 : 200 flow to ps 1.5 inch - 25 Yr 1.00 0.90 0.80 0.70 0.60 0.50 I 0.40 l� 0.30 1 i 0.20 i u i 0.10 0.00 - 0.0 2.5 5.0 7.5 Type III Design Storm Hydrograph Volume = 168,080 cult Precip (in) 1.00 0.90 0.80 0.70 0.60 0.50 0.40 0.30 0.20 0.10 0.00 10.0 12.5 15.0 17.5 20.0 22.5 25.0 Time (hrs) DA-200 Precipitation at Cummulative Cummulative Peak Runoff Hour Mark Last 5 min. of hour Precipitation for Hour Precipitation for Storm cfs 1 0._0075 �0.0075 0.09 0.09 2 0.09 0.18 3 0.0086 0.1032 0.2832 4 0.0097 0.1164 0.3996 51 0.0108 0.1296 0.5292 6 0.0119 0.1428 0.672 7 0.0156 0.1872 0.8592 8 0.0193 0.2316 1.0908 9 0.0277 0.3324 1.4232 9.25 0.0299 0.0897 1.5129 1.8 Hydrograph Plot Hydraflow Hydrographs by Intelisolve Hyd. No. 1 200 flow to ps 1.5 inch Hydrograph type = SCS Runoff Storm frequency = 25 yrs Drainage area = 5.500 ac Basin Slope = 1.5 % Tc method = USER Total precip. = 8.98 in Storm duration = 24 hrs Q (cfs) 40.00 30.00 20.00 10.00 Wednesday, May 23 2007, 4:45 AM Peak discharge = 35.21 cfs Time interval = 5 min Curve number = 100 Hydraulic length = 1500 ft Time of conc. (Tc) = 10.00 min Distribution = Type III Shape factor = 484 200 flow to ps 1.5 inch Hyd. No. 1 -- 25 Yr 3 5 8 10 j, z 5' Hyd No. 1 Hydrograph Volume = 168,080 cuft 13 15 18 20 23 Q (cfs) 40.00 f 1111111 10.00 �--1 0.00 25 Time (hrs) a ro 0 0 N M W r L E Q O p N N X r O CD L C a) t j II � U' cEa I � Lo (D a EY � y V O C U a) _! 9' O O .0 N O to •� U L mn a) 1 U. U �' = w _ E d o 7 ��6a)ha) 3 L O 0-�� )a a)_ N C p5 o CL C 0 L C -0 a) L a M a) U a) o a) U CM '$ O ` Co D0E�, ;= u °� r � y m - 3 � a E a) O ca -a O C U C a) � E a o N s Y 0 c) CD L a) p L' CL � a) a) y.0 a) .O ca o- m 5 > E E _ a) — O N �iii� -- cowl 0 c� N C m x W. 0 t CL MNrO00ti0 a CD r r r d CL 0 CL! w C O iF M N N N co N CL w; 'Mm1,r9?OLova Oc = d CO N N h M N O V LO N N r a0 0; 0 C r r r r O_ m y W r M OI Y� r CO r 0 w CO) N O CO CO) CDCD M V M N N r r r 0 0 tA\ G000�YOYlFMN� r CL as CL E C. d IL Hydrograph Plot Hydraflow Hydrographs by Intelisolve Hyd. No. 1 300 flow to ps 1.5 inch Hydrograph type = SCS Runoff Storm frequency = 25 yrs Drainage area = 2.300 ac Basin Slope = 1.5 % Tc method = USER Total precip. = 8.98 in Storm duration = 24 hrs Wednesday, May 23 2007, 4:40 AM Peak discharge = 14.72 cfs Time interval = 5 min Curve number = 100 Hydraulic length = 800 ft Time of conc. (Tc) = 10.00 min Distribution = Type III Shape factor = 484 Incremental Rainfall Precipitation Precip (in) Hyd. No. 1 : 300 flow to ps 1.5 inch - 25 Yr 1.00 0.90 0.80 0.70 0.60 0.50 0.40 0.30 I 1 0.20 0.10 0.0 2.5 5.0 7.5 Type III Design Storm Hydrograph Volume 70,288 cuft Precip (in) 1.00 0.90 0.80 0.70 0.60 0.50 0.40 0.30 0.20 0.10 o.00 10.0 12.5 15.0 17.5 20.0 22.5 25.0 Time (hrs) DA-300 Precipitation at Cummulative Cummulative Peak Runoff Hour Mark Last 5 min. of hour Precipitation for Hour Precipitation for Storm cfs 1 0.0075 0.09 0.09 2 0.0075 0.09 0.18 3 0.0086 0.1032 0.2832 4 0.0097 0.1164 0.3996 5 0.0108 0.1296 0.5292 6 0.0119 0.1428 0.672 7 0.0156 0.1872 0.8592 8 0.0193 0.2316 1.0908 9 0.0277 0.3324 1.4232 9.25 0.0299 0.0897 1.5129 0.75 Hydrograph Not Hyd. No. 1 300 flow to ps 1.5 inch Hydrograph type = SCS Runoff Storm frequency = 25 yrs Drainage area = 2.300 ac Basin Slope = 1.5 % Tc method = USER Total precip. = 8.98 -in Storm duration = 24 hrs Q (cfs) 15.00 12.00 90 o. 7's 0.00 0 3 5 Hyd No. 1 300 flow to ps 1.5 inch Hyd. No. 1 — 25 Yr Wednesday, May 23 2007, 4:40 AM Peak discharge = 14.72 cfs Time interval = 5 min Curve number = 100 Hydraulic length = 800 ft Time of conc. (Tc) = 10.00 min Distribution = Type III Shape factor = 484 Hydrograph Volume = 70,288 cult Q (cfs) 15.00 12.00 M 3.00 i , I --- _r ------- 1 0.00 8 1 10 13 15 18 20 23 25 Q, Z S Time (hrs) a) �A2 O O O E C U a) ^ N t O ° U L O N p C s _ E Ch ' LL N O U N U 'r E +L+ 'c .cC C U i c CL N p :3 L C Er CA = a) U a) v) °E >, -� O °tm o a) N � 7 � Ea) oca-0 c m 0`)3w:�° 0 Y m C e Q. 7 O i a) > U cc _ a) K () W v i �i ILO 0 0 N M a d E w ot *! zr! to CL C) Coq,MNNNMN C. a+ � O C) at ehriMMCV rich Oa = Ate.) Co em CmCD I+ M N in T r T T T ad0; Cd CM N v d 0 0 Co O Co le 05 x 00rMO7 tpTaDr U, MI�OtOMOtOM v M N N r t 0 0 Co o 0O0 eOO w dOn lcaq d CL E C a) a; IL 12.0 STDRIVILWATER PUMP DESIGN DATA (M LO 0 0 0 :v m U) LL PERFORMANCE PRODUCT TYPE CURVE NP3153.181 LT DATE PROJECT CURVE NO ISSUE 2007-05-22 Waterway Cove 63-416-00-3010 1 1/1-LOAD 3/4-LOAD 1/2-LOAD RATED IMPELLER DIAMETER POWER FACTOR 0.79 0.72 0.60 POWER ..... 12 hp STARTING 187 mm EFFICIENCY 87.0 % 87.5 % 86.0 % CURRENT ... 102 A MOTOR # STATOR REV MOTOR DATA __ __ _ RATED CURRENT ... 16 A RATED 1760 21-13-4AA 05YSER 111 COMMENTS INLET/OUTLET FREQ. PHASES VOLTAGE POLES -/ 8 inch rpm OT.MOM.OF 60 Hz 3 460 V 4 INERTIA... 0.055 kgm2 IMP. THROUGHLET GEARTYPE RATIO NO. OF --- BLADES 2 --- --- ��u W [hp] o a a 12 LL a Q z = w � O Lu 10 1 o 8 LL LL W LL: J LL Q W a a. O a DUTY -POINT FLOW[usgpm] HEAD[ft] POWER [hp] EFF. [%] NPSHre[ft] 0 1 741 31.0 11.7 (10.2) 49.6 (56.7) 31.3 B.E.P. 1349 22.6 12.2 (10.7) 63.5 (72.7) 28.7 NPSHrea. [ft] Z 0 [ftj NPSH a=36 LL 45 45ui w w m 40 40 [- EFF. 35 35 0 30 30 60 1 Q W 25 = 25 50 20 2D 40 15 15 30 10 1D 20 5 5 10 o D 0 400 800 1200 1600 2000 [USgpm] FLOW NPSHre = NPSH3%+ min. operational margin M f Oa WATERWAY COVE AREA 100 - STORMWATER PUMPING STATION SYSTEM HEAD CURVE COMPUTATIONS EQUIVALENT LENGTHS FOR FITTINGS Quantity Item Equivalent Loss Per Fitting TOTAL Force Main 0 90° BEND 32 0 6 45° BEND 16 96 2 22.5° BEND 16 32 Pump Station 1 90' BEND - Long Red. 20 20 1 90' BEND 32 32 0 45° BEND 16 0 0 22.5* BEND 16 0 1 GATE VALVE 13 13 1 SWING CHECK VALVE 80 80 1 TEE -SIDE ENTRY 22 22 FITTINGS 295 FEET LENGTH OF PIPE DIP 1685 FEET TOTAL EQUIVALENT LENGTH OF PIPE FEET STATIC HEAD CALCULATIONS DISCHARGE ELEV 33 Pipe Outlet LOW WW 8.2 Pumps Off HIGH WW 10.2 STATIC HEAD LOW WW 24.9 STATIC HEAD HIGH WW 22.8 DESIGN FLOW Peak Flow Design Flow CFS GPM 1.7 762.96 100 HAZEN WILLIAMS HEAD LOSS CALCULATIONS - 8" Pipe Friction Factor - C 140 Pipe ID - inches 8 Equivalent Length - _ ftMW Static Head - ft 24.8 Flow Head Loss Per 100' Head Loss TDH Velocity GPM ft per 100 ft ft ft ft/s 0 0 0 24.8 0 25 0.001750091 0.0346518 24.8346518 0.156582031 50 0.006317835 0.1250931 24.9250931 0.313164063 75 0.013387185 0.2650663 25.0650663 0.469746094 100 0.022807402 0.4515866 25.2515866 0.626328125 125 0.034478881 0.6826818 25.4826818 0.782910156 150 0.048327778 0.95689 25.75689 0.939492188 175 0.064295752 1.2730559 26.0730559 1.096074219 200 0.082334787 1.6302288 26.4302288 1.25265625 225 0.102404217 2.0276035 26.8276035 1.409238281 250 0.12446886 2.4644834 27.2644834 1.565820313 275 0.148497781 2.9402561 27.7402561 1.722402344 300 0.174463419 3.4543757 28.2543757 1.878984375 325 0.202340957 4.006351 28.806351 2,035566406 350 0.232107853 4.5957355 29.3957355 2.192148438 375 0.263743475 5.2221208 30.0221208 2.348730469 400 0.297228822 5.8851307 30.6851307 2.5053125 425 0.332546296 6.5844167 31.3844167 2.661894531 450 0.36967952 7.3196545 32.1196545 2.818476563 476 0.40861319 8.0905412 32.8905412 2.975058594 500 0.449332947 8.8967924 33.6967924 3.131640625 525 0.491825278 9.7381405 34.5381405 3.288222656 550 0.536077423 10.614333 35.414333 3.444804688 575 0.582077302 11.525131 36.3251306 3.601386719 600 0.629813451 12.470306 37.2703063 3.75796875 625 0.679274964 13.449644 38.2496443 3.914550781 650 0.730451445 14.462939 39.2629386 4.071132813 675 0.783332965 15.509993 40.3099927 4.227714844 700 0.837910025 16.590618 41.3906185 4.384296875 725 0.89417352 17.704636 42.5046357 4.540878906 750 0.952114712 18.851871 43.6518713 4.697460938 775 1.0117252Q4 20.032159 44.832159 4.854042969 800 1.072996912 21.245339 46.0453389 5.010625 825 1.135922047 22.491257 47.2912565 5.167207031 850 1.200493095 23.769763 48.5697633 5.323789063 875 1.266702799 25.080715 49.8807154 5.480371094 900 1.334544143 26.423974 51.223974 5.636953125 925 1.404010337 27.799405 52.5994047 5.793535156 960 1,475094804 29.206877 54.0068771 5.950117188 975 1.b47791169 30.646265 55.4462651 6.106699219 1000 1.622093247 32.117446 56.9174463 6.26328125 763 0.982904358 19.461506 44.2615063 4.778883594 DESIGN POINT fG0 HAZEN WILLIAMS HEAD LOSS CALCULATIONS - 10" Pipe Friction Factor - C 140 Pipe ID - inches 10 Equivalent Length - ft Static Head - ft Plow Head Loss Per 100' Head Loss TDH Velocity GPM ft per 100 ft ft ft ft/s 0 0 0 24.8 0 25 0.000590942 0.0117007 24.8117007 0.1002125 50 0.002133303 0.0422394 24.8422394 0.200425 75 0.004520366 0.0895032 24.8895032 0.3006375 100 0.007701231 0.1524844 24.9524844 0.40085 125 0.011642265 0.2305169 25.0305169 0.5010625 150 0.016318535 0.323107 25.123107 0.601275 175 0.021710339 0.4298647 25.2298647 0.7014875 200 0.027801466 0.550469 25.350469 0.8017 225 0.034578183 0.684648 25.484648 0.9019125 250 0.042028612 0.8321665 25.6321665 1.002125 275 0.050142305 0.9928176 25.7928176 1.1023375 300 0.058909958 1.1664172 25.9664172 1.20255 325 0.06832319 1.3527992 26.1527992 1.3027625 350 0.078374389 1.5518129 26.3518129 1.402975 375 0.089056589 1.7633205 26.5633205 1.5031875 400 0.100363374 1.9871948 26.7871948 1.6034 425 0.112288801 2.2233183 27.0233183 1.7036125 450 0.124827342 2.4715814 27.2715814 1.803825 475 0.137973828 ' 2.7318818 27.5318818 1.9040375 900 0.15172341 3.0041235 27.8041235 2.00425 525 0.166071527 3.2882162 28.0882162 2.1044625 550 0.181013868 3.5840746 28.3840746 2.204675 575 0.196546356 3.8916178 28.6916178 2.3048875 600 0.212665119 4.2107694 29.0107694 2.4051 625 0.229366476 4.5414562 29.3414562 2.5053125 650 0,246646913 4.8836089 29.6836089 2.605525 675 0.264503081 5.237161 30.037161 2.7057375 700 0.282931771 5.6020491 30.4020491 2.80595 725 0,301929909 5.9782122 30.7782122 2:9061625 750. 0.321494544 6.365592 31.165592 3.006375 775 0.341622842 6.7641323 31.5641323 3.1065875 800 0.362312071 7.173779 31.973779 3.2068 825 0.383559603 7.5944801 32.3944801 3.3070125 850 0.4053629 8.0261854 32.8261854 3.407225 875 0.427719511 8.4688463 33.2688463 3.5074375 900 0.460627068 8.922416 33.722416 3.60765 925 0.474083278 9.3868489 34.1868489 3.7078625 960 0.49808592 9.8621012 34.6621012 3.808075 975 0.522632841 10.34813 35.1481302 3.9082875 1000 0.547721953 10.844895 35.6448947 4.0085 763 0.331891089 6.5714436 31.3714436 3.0584855 DESIGN POINT Cn 0 (D 0 0 Co J u_ >�x- ji:w: PERFORMANCE PRODUCT TYPE CURVE NP3153.181 LT DATE PROJECT CURVE NO ISSUE 2007-05-22 Waterway Cove 63-416-00-3010 1 1/1-LOAD 3/4-LOAD 1/2-LOAD RATED IMPELLER DIAMETER POWER ..... 12 hp 187 mm POWER FACTOR 0.79 0.72 0.60 STARTING EFFICIENCY 87.0 % 87.5 % 86.0 % CURRENT... 102 A MOTOR # STATOR REV MOTOR DATA RATED CURRENT ... 16 A RATED 1760 21-13-4AA 105YSER 111 COMMENTS INLET/OUTLET FREQ. PHASES VOLTAGE POLES 4 8 inch rpm TOT.MOM.OF 60 Hz 3 460 V 4 INERTIA ... 0.055 kgm2 IMP. THROUGHLET GEARTYPE RATIO NO. OF --- BLADES --- --- [hp] ��u W o a a F u~ 12 Q a = z Co ry O jc Lu 10 1 O 8 U_ W LL J U_ J LU � d O d DUTY -POINT FLOW[Usgpm] HEAD[ft] POWER [hp] EFF. [°A] NPSHre[ft] O 1 777 30.4 11.7 (10.2) 51.0 (58.3) 31.1 B.E.P. 1349 22.6 12.2 (10.7) 63.5 (72.7) 28.7 PS H re IN Z [ftj NPSH a=36 45 U_ F 45 Co w m 40 - 40 [- EFF. 35 35 [%] 0 30 1 30 60 W 25 = 25 50 20 20 40 15 15 30 10 10 20 5 5 10 0 0 0 400 800, 1200 1600 2000 [USgpm] FLOW KIPP,Hrp o NPRI-110n + min nnpratinnal margin e .. , re 200 200 WATERWAY COVE AREA 200 - STORMWATER PUMPING STATION SYSTEM HEAD CURVE COMPUTATIONS EQUIVALENT LENGTHS FOR FITTINGS Quantity Item Equivalent Loss Per Fitting TOTAL Force Main 0 90' BEND 32 0 6 45° BEND 16 96 4 22.5° BEND 16 64 Pump Station 1 90° BEND - Long Red. 20 20 1 90° BEND 32 32 0 45° BEND 16 0 0 22.5° BEND 16 0 1 GATE VALVE 13 13 1 SWING CHECK VALVE' 80 80 1 TEE -SIDE ENTRY 22 22 FITTINGS 327 FEET LENGTH OF PIPE DIP 1400 FEET TOTAL EQUIVALENT LENGTH OF PIPE i � i FEET STATIC HEAD CALCULATIONS DISCHARGE ELEV 33 Pipe Outlet LOW WW 8.5 Pumps Off HIGH WW g o5 STATIC HEAD LOW WW STATIC HEAD HIGH WW 22, DESIGN FLOW Peak Flow Design Flow CFS GPM 1.8 807.84 HAZEN WILLIAMS HEAD LOSS CALCULATIONS - 8" Pipe Friction Factor - C 140 Pipe ID - inches 8 Equivalent Length - ft Static Head - ft 24.5 Flow Head Loss Per 100' Head Loss TDH Velocity GPM ft per 100 ft ft ft ftfs 0 0 0 24.5 0 25 0.001750091 0.0302241 24.5302241 0.156582031 50 0.006317835 0.109109 24.609109 0.313164063 75 0.013387185 0.2311967 24.7311967 0.469746094 100 0.022807402 0.3938838 24.8938838 0.626328125 125 0.034478881 0.5954503 25.0954503 0.782910156 150 0.048327778 0.8346207 25.3346207 0.939492188 175 0.064295752 1.1103876 25,6103876 1.096074219 200 0.082334787 1.4219218 25.9219218 1.25265625 225 0.102404217 1.7685208 26.2685208 1.409238281 250 0.12446886 2.1495772 26.6495772 1.565820313 275 0.148497781 2.5645567 27.0645567 1.722402344 300 0.174463419 3.0129833 27.5129833 1.878984375 325 0.202340957 3.4944283 27.9944283 2.035566406 350 0.232107853 4.0085026 28.5085026 2.192148438 375 0.263743475 4.5548498 29.0548498 2.348730469 400 0.297228822 5.1331418 29.6331418 2.5053125 425 0.332546296 5.7430745 30.2430745 2.661894531 450 0.36967952 6.3843653 30.8843653 2.818476563 475 0.40861319 7.0567498 31.5567498 2.975058594 500 0.449332947 7.75998 32.25998 3.131640625 525 0.491825278 8.4938226 32.9938226 3.288222656 550 0.536077423 9.2580571 33.7580571 3.444804688 575 0.582077302 10.052475 34.552475 3.601386719 600 0.629813451 10.876878 35.3768783 3.75796875 625 0.679274964 11.731079 36.2310786 3.914550781 050 0.730451445 12.614896 37.1148965 4.071132813 675 0.783332965 13.52816 38.0281603 4.227714844 700 0.837910025 14.470706 38.9707061 4.384296875 725 0.89417352 15.442377 39.9423767 4.540878906 750 0.952114712 16.443021 40.9430211 4.697460938 775 1.011725204 17.472494 41.9724943 4.854042969 800 1.072996912 18.530657 43.0306567 5.010625 825 1.135922047 19.617374 44.1173738 5.167207031 850. 1.200493095 20.732516 45.2325158 5.323789063 875 1.266702799 21.875957 46.3759573 5.480371094 900 1.334544143 23.047577 47.5475774 5.636953125 925 1.404010337 24.247259 48.7472585 5.793535156 950 1.475094804 25.474887 49.9748873 5.950117188 975 1.547791169 26.730353 51.2303535 6.106699219 1000 1.622093247 28.01355 52.5135504 6.26328125 808 1.092953427 18.875306 43.3753057 5.06073125 DESIGN POINT zoo HAZEN WILLIAMS HEAD LOSS CALCULATIONS - 10" Pipe Friction Factor - C 140 Pipe ID - inches 10 Equivalent Length - ft Static Head - ft 24.6 Flow Head Loss Per 100' Head Loss TDH Velocity GPM ft per 100 ft ft ft ftfs 0 0 0 24.5 0 25 0.000590942 0.0102056 24.5102056 0.1002125 50 0.002133303 0.0368421 24.5368421 '0.200425 75 0.004520366 0.0780667 24.5780667 0.3006375 100 0.007701231 0.1330603 24.6330003 0.40085 125 0.011642265 0.2010619 24.7010619 0.5010625 150 0.016318535 0.2818211 24.7818211 0.601275 175 0.021710339 0.3749376 24.8749376 0.7014875 200 0.027801466 0.4801313 24.9801313 0.8017 225 0.034578183 0.5971652 25.0971652 0.9019125 250 0.042028612 0.7258341 25.2258341 1.002125 275 0.050142305 0.8659576 25.3659576 1.1023375 300 0.068909958 1.017375 25.517375 1.20255 325 0.06832319 1.1799415 25.6799415 1.3027625 350 0.078374389 1.3535257 25.8535257 1.402975 375 0.089056589 1.5380073 26.0380073 1.5031875 400 0.100363374 1.7332755 26.2332755 1.6034 425 0.112288801 1.9392276 26.4392276 1.7036125 450 0.124827342 2,1557682 26.6557682 1.803825 475 0.137973828 2.382808 26.882808 1.9040375 500 0.15172341 2.6202633 27.1202633 2.00425 525 0.166071527 2.8680553 27.3680553 2.1044625 550 0.181013868 3.1261095 27.6261095 2.204675 575 0.196546356 3.3943556 27.8943556 2.3048875 600 0.212665119 3.6727266 28.1727266 2.4051 625 0.229366475 3.961159 28.461159 2.5053125 650 0.246646913 4.2595922 28.7595922 2.605525 675 0.264503081 4.5679682 29.0679682 2.7057375 700 0.282931771 4.8862317 29.3862317 2.80595 725 0.301929909 5.2143295 29.7143295 2.9061625 750 0.321494544 5.5522108 30.0522108 3,006375 775 0.341622842 5.8998265 30.3998265 3.1065875 800 0.362312071 6.2571295 30.7571295 3.2068 825 0.383559603 6.6240743 31.1240743 3.3070125 850 0.4053629 7.0006173 31.5006173 3.407225 875 0.427719511 7.386716 31.886716 3.5074375 900 0.450627068 7.7823295 32.2823295 3.60765 925 0.474083278 8.1874182 32.6874182 3.7078625 950 0.49808592 8.6019438 33.1019438 3.808075 975 0.522632841 9.0258692 33.5258692 3.9082875 1000 0.547721953 9.4591581 33.9591581 4.0085 808 0.369050661 6.3735049 30.8735049 3.238868 DESIGN POINT cm uo o co 0 0 PRODUCT TYPE lrx; PERFORMANCE CURVE NP3085.183 MT DATE PROJECT CURVE NO ISSUE 2007-05-22 Waterway Cove 63-463-00-3806 4 1/1-LOAD 3/4-LOAD 1/2-LOAD RATED IMPELLER DIAMETER POWER ..... 2.2 hp 135 mm POWER FACTOR 0.87 0.83 0.75 STARTING EFFICIENCY 71.5 % 74.0 % 73.0 % CURRENT ... 14 A MOTOR # STATOR REV MOTOR DATA -_ _ _- RATED CURRENT... 3.3 A RATED 1670 15-07-4AL 12YSER 12 COMMENTS INLET/OUTLET FREQ. PHASES VOLTAGE POLES - / 3.0 inch rpm TOT.MOM.OF 60 Hz 3 460 V 4 INERTIA ... 0.017 kgm2 IMP. THROUGHLET GEARTYPE RATIO NO. OF --- BLADES 2 --- ui [hp] ui O a0. a 2.4 H LL � ¢ a = � o� Uj 2.0 3. 1.6 w ,L: J LL Q w IL O a DUTY -POINT FLOW[U8gpm] HEAD[ft] POWER [hp] EFF. [%] NPSHre[ft] 0 k 1 296 14.1 2.61 (2.01) 41.4 (53.3) 13.7 B.E.P. 333 12.8 2.60 (2.02) 41.6 (53.6) 13.4 N PS H re [ftl Z [ft]EL LL LL w r 25 w 00 25 r- EFF. 20 [%] 20 a w 15 2 15 30 1 10 10 20 6-1 1 ' 5 10 0 0 0 100 200 300 400 500 [USgpm] FLOW AIPCI-Ir= = KIPAWAO + min nnaratinnnI mnrnin I . .. , " .3G6 Sod WATERWAY COVE AREA 300 - STORMWATER PUMPING STATION SYSTEM HEAD CURVE COMPUTATIONS EQUIVALENT LENGTHS FOR FITTINGS Quantity Item Equivalent Loss Per Fitting TOTAL Force Main 0 90° BEND 32 0 1 45' BEND 16 16 3 22.5° BEND 16 48 Pump Station 1 90° BEND - Long Rad. 20 20 1 90° BEND 32 32 0 45' BEND 16 0 0 22.5° BEND 16 0 1 GATE VALVE 13 13 1 SWING CHECK VALVE 80 80 1 TEE -SIDE ENTRY 22 22 FITTINGS 231 FEET LENGTH OF PIPE DIP 415 FEET TOTAL EQUIVALENT LENGTH OF PIPEFEET STATIC HEAD CALCULATIONS DISCHARGE ELEV 17.2 Pipe Outlet LOW WW 7.5 Pumps Off HIGH WW 9.5 STATIC HEAD LOW WW R1 STATIC HEAD HIGH WW 7.7 DESIGN FLOW Peak Flow Design Flow CFS GPM 0.7 314.16 Sao HAZEN WILLIAMS HEAD LOSS CALCULATIONS - 4" Pipe Friction Factor - C 140 Pipe ID - inches 4 Equivalent Length - ft . W , . .1. . . Static Head - ft 9.7 Flow Head Loss Per 100' Head Loss TDH Velocity GPM ft per 100 ft ft ft ft/s 0 0 0 9.7 0 25 0.05101785 0.3295753 10.0295753 0.626328125 50 0.184174588 1.1897678 10.8897678 1.25265625 75 0.390257016 2.5210603 12.2210603 1.878984375 100 0.6648708 4.2950654 13.9950654 2.5053,25 125 1.005112338 6.4930257 16.1930257 3.131640625 150 1.408828965 9.1010351 18.8010351 3.75796875 175 1.874319943 12.108107 21.8081068 4.384296875 200 2.400185524 15.505198 25.2051985 5.010625 225 2.985240216 19.284652 28.9846518 5.636953125 250 3.628458465 23.439842 33.1398417 6.26328125 275 4.328938431 27.964942 37.6649423 6.889609375 300 5.085876661 32.854763 42.5547632 7.5159375 325 5.898549721 38,104631 47.8046312 8.142265625 350 6.766300449 43.710301 53.4103009 8.76859375 375 7.688527426 49.667887 59.3678872 9.394921875 400 8.664676724 55.973812 65.6738116 10.02125 425 9.694235339 62.62476 72.3247603 10.64757813 450 10.77672587 69.617649 79.3176491 11.27390625 475 11.91170214 76.949596 86.6495958 11.90023438 500 13.09874562 84.617897 94,3178967 12.5265625 525 14.33746233 92.620007 102.320007 13.15289063 550 15.62748033 100.95352 110.653523 13.77921875 575 16.96844747 109.61617 119.316171 14.40554688 600 18.36002955 118.60579 128.305791 15.031875 625 19.80190863 127.92033 137.62033 15.65820313 650 21.29378166 137.55783 147.25783 16.28453125 675 22.83535919 147.51642 157.21642 16.91086938 700 24.42636431 157.79431 167.494313 17.5371875 725 26.06653161 168.38979 178.089794 18.16351563 750 27.75560638 179.30122 189.001217 18.78984375 775 29.49334378 190.527 200.227001 19.41617188 800 31.27950819 202.06562 211.765623 20.0425 825 33,11387254 213.91562 223.615617 20.66882813 850 34.99621778 226.07557 235.775567 21.29515625 875 36.92633236 238.54411 248.244107 21.92148438 900 38.90401173 251.31992 261.019916 22.5478125 925 40.92905798, 264.40171 274.101715 23.17414063 950 43.00127939 277.78826 287.488265 23.80046875 975 45.1204901 291.47837 301.178366 24.42679688 1000 47.2865098 305.47085 315.170853 25.053125 315 5.566835725 35.961759 45.6617588 7.891734375 DESIGN POINT 300 HAZEN WILLIAMS HEAD LOSS CALCULATIONS - 6" Pipe Friction Factor - C 140 Pipe ID- inches 6 Equivalent Length - ft Static Head - ft 9: - Flow Head Loss Per 100' Head Loss TDH Velocity GPM ft per 100 ft ft ft ft/s 0 .0 0 9.7 0 25 0.007094963 0.0458335 9.74583346 0.278368056 50 0.025612837 0.1654589 9.86545893 0.556736111 75 0.054272359 0.3505994 10.0505994 0.835104167 106 0.092462416 0.5973072 10.2973072 1.113472222 125 0.139779211 0.9029737 10.6029737 1.391840278 150 0.195923374 1.265665 10.965665 1.670208333 175 0.260658388 1.6838532 11.3838532 1.948576389 200 0.333789592 2.1562808 11.8562808 2.226944444 225 0.415152123 2.6818827 12.3818827 2.6053125 250 0.504603357 3.2597377 12.9597377 2.783680556 275 0.602017877 3.8890355 13.5890355 3.062048611 300 0.70728395 4.5690543 14.2690543 3.340416667 325 0.820300967 5.2991442 14.9991442 3.618784722 350 0.94097754 6.0787149 15.7787149 3.897152778 375 1.069230028 6.907226 16.607226 4.175520833 400 1.2049814 7.7841798 17.4841798 4.453888889 425 1,348160311 8.7091156 18.4091156 4.732256944 450 1.49870037 9.6816044 19.3816044 5.010625 475 1.656539531 10.701245 20.4012454 5.288993056 500 1.821619586 11.767663 21.4676625 5.567361111 525 1.993885748 12.880502 22.5805019 5.845729167 550 2.173286289 14.039.429 23.7394294 6.124097222 575 2.359772238 15.244129 24.9441287 6.402465278 600 2.553297117 16.494299 26,1942994 6.680833333 625 2.753816712 17.789656 27.489656 6.959201389 650 2.961288879 19.129926 28.8299262 7.237569444 675 3.175673364 20.51485 30.2148499 7.5159375 700 3.396931656 21.944178 31.6441785 7.794305556 726 3.625026847 23.417673 33.1176734 8.072673611 750 3.859923513 24.935106 34.6351059 8.351041667 775 4.101587607 26.496256 36.1962559 8.629409722 800 4.349986359 28.100912 37.8009119 8.907777778 825 4.605088193 29.74887 39.4488697 9.186145833 850 4.866862645 31.439933 41.1399327 9.464513889 875 5.135280295 33.173911 42.8739107 9.742881944 900 5.410312698 34.95062 44.65062 10.02125 925 5.691932329 36.769883 46.4698828 10.29961806 950 5.980112527 38.631527 48.3315269 10.57798611 975 6.274827445 40.535385 50.2353853 10.85635417 1000 6.576052006 42.48,1296 52.181296 11.13472222 315 0.774170084 5.0011387 14.7011387 3.5074375 DESIGN POINT 13.0 UNDERGROUND INFILTRATION TRENCH SIZING Engineering, Landscape Architecture and Environmental Science OVA' MILONE & MACBROOW 5511 Capital Center Drive, Suite 106 Raleigh, North Carolina 27606 (919) 854-4373 Fax (919) 854-4393 JOB ":' (Akl 7 *Inv( 6M??Tz- SHEET NO. OF CALCULATED BY CHECKED BY " ....------ : 1 - -...-. .. . " 3 -- Froneering, Landscape Architechire and Eindronmental Science I MILONE & MACBROOM° 5511 Capital Center Drive, Suite 106 Raleigh, North Carolina 27606 (919)554-4373 raX(YlY)tfS4-437s UNDISTURBED EARTH 6" ABOVE PIPE CROWN JOB 1704 t -3 9 CJrErzs: Corn SHEET NO. OF CALCULATED BY DATE CHECKED BY DATE H (MIN. COVER TO PAVEMENT) FINAL BACKFILL GEOTEXTILE FILTER FABRIC (TOP & SIDES) CLEAN WASHED # GRANITE STONE BEDDING OR APPROVED EQUAL (MIMIMUM 40 % VOID RATIO) 4" CLEAN SAND (NATIVE MATERIAL WHERE SUITABLE) Pale 2.25, _, ......: .. _. .. _.... _. �U��tiUdcumC _. 1 T"s ------------ _ 1r.)-r4L yowm Qcz-o g - V- - 72 L f�1. %-� ' l3�3CGc� Ire, 13 141�-Jw Engineering, Landscape Architecture and Environmental Science MILONE & MACSROOM® 5511 Capital Center Drive, Suite 106 Raleigh, North Carolina 27606 (919) 854-4373 Fax(919) 854-4393 JOB CL L I—�p(GIIOU C.lhrlr. SHEET NO. OF CALCULATED BY CHECKED BY Engineering, Landscape Architecture and Environmental Science MILONE & MACBROOW 5511 Capital Center Drive, Suite 106 Raleigh, North Carolina 27606 (919)854-4373 Fax (919) 854-4393 JOB X `7 l m &nx- SHEET NO. CALCULATED BY CHECKED Bf OF DATE Engineering, Landscape Architecture and Environmental Science MILONE & MACBROOM® 5511 Capital Center Drive, Suite 106 Raleigh, North Carolina 27606 (919) 854-4373 Fax(919) 854-4393 JOB20q(-&: WIWIWMJa./ Cry e- SHEET NO. OF CALCULATED BY CHECKED BY DATE I r I f •s f { ....... _..... _-.-------- .... .. - - - _. _..t.__.._; ... i ,.. .........� y.,_........ �. �._.. ....... ..... ..... ....... ... L .__.._.i- Y__—. _ +_.. .... _....... 1 i I _.... . _ .. _ O ST O TA -Hoeq uo spenaa (B 'papnloui mnluej &!,.oag O O O N (_D N U 2z2 aNd, U. N t0 Y0co Z Q m J J H W c W H Q m Z La 0 N OD O! W �Z"D F-=w �W QLU j aCC m U W a 64 O O Z v w c m 0 U c Z m O LULL F-O O 0 Q L0 w Z w U Z i I i LD L13 U1 ru i U-1 Ln [A L13 o' a O O O rri Ln O —0 m O a� 3 E 0 m a 2 w O 0 ri O O O O E O O TO O O O O d N N � � c 00 U O N .N E N j5 Q CN Y O N � 0U oo a) O U C cN (a W m w O E O Q O O (p O O N LM O J J W N LL LU Q C3 N CQ 2 O c U) w C7 Q a) -� Z H CO w U o Z N CD CO N LU Do Q 4� A%' r••e: Cr a) N 3 O cn O O as U E Q 0 Y C m m r -- o�oF wa rF9QG r > _I O � _-_ -June 21, 2007 Kyle Corkum, Manager Waterboro Village, LLC 5511 Captial Center Drive, Suite 105 Raleigh, NC 27606 Subject: Request for Additional Information Stormwater Project No. SW8 070544 Waterway Cove Brunswick County Dear Mr. Corkum: Michael F. Easley, Governor William G. Ross..lr.,.Secretary North Carolina Department of Environment and Natural Resources Coleen H. Sullins, Director Division of Water Quality The Wilmington Regional Office received a Stormwater Management Permit Application for Waterway Cove on May 29,2007. A second review of that information has determined that the application is not complete. The following information is needed to continue the stormwater review: 1. All plan sheets must have a P.E. seal not just the cover, please correct. 2. Infiltration trenches INF-100, 200, 300 and trenches Type A,B,and C are undersized. It appears from the calculations provided that only the built -upon area was used to determine the runoff. Schuler's method or a more conservative method must be used to determine stormwater runoff, please correct. 3. No calculations were provided for trench types A, B, C, D, and E, please provide calculations. 4. On the application please break out the single family lots and townhomes that will be treated on the individual lots into one separate drainage area for reporting purposes. Because the application has significant permitting issues/deficiencies, a resubmittal fee of $2,000 will be required in order for this project to remain in the express program. Please note that this request for additional information is in response to a preliminary review. The requested information should be received by this Office prior to June 28, 2007, or the application will be returned as incomplete. The return of a project will necessitate resubmittal of all required items, including the application fee. If you need additional time to submit the information, please mail or fax your request for a time extension to the Division at the address and fax number at the bottom of this letter. The request must indicate the date by which you expect to submit the required information. Nti a Carolina Natutally North Carolina Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 Phone (919) 733-7015 Customer Service Internet: www.ncwaterguality.org Location. N. 512 Salisbury St. Raleigh, NC 27604 Fax (919) 733-2496 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer— 50% Recycledl10% Post Consumer Paper Kyle Corkum, Manager June 12, 2007 Stormwater Application No. SW8070544 The construction of any impervious surfaces, other than a construction entrance under an approved Sedimentation Erosion Control Plan, is a violation of NCGS 143-215.1 and is subject to enforcement action pursuant to NCGS 143-215.6A. Please reference the State assigned project number on all correspondence. Any original documents that need to be revised have been sent to the engineer or agent. All original documents must be returned or new originals must be provided. Copies are not acceptable. If you have any questions concerning this matter please feel free to call me at (910) 796-7304. Sincerely, Chris Baker "Environmental Engineer II ENB/csb: S:IWQSISTORMWATERIADDINFO120071070544.jun07 cc: Reuben Jones, Milone and Macbroom, Inc. File Page 2 of 2 Engineering, Landscape Architecture and Environmental Science MILONE & MACBROOM TO NC DEIVR, Wilmington Regional Office Division of Water Quality LETTER OF TRANSMITTAL Date: 06/15/2007 1 Job No. 2041-38 Attention: Chris Baker RE: Waterway Cove Stormwater Management Permit Application Revisions WE ARE SENDING YOU [] Attached Under separate cover via UPS the following items: [ ] Shop Drawings [ ] Copy of Letter [ ] Prints El Plans [ ] Samples [ ] Specifications [ ] Change Order [ ] Copies Date No. Description 2 05125/07 - Title Sheet for Waterway Cove Stormwater Management Plan Set 24x36",Sealed 5-25-2007 2 05/21/07 EX-1 Existing Conditions — 2406" 2 05/23/07 DWQ-1 Overall Stormwater Management Plan — 2406" 2 05/23/07 DWQ-2 Drainage Areas and Built Upon Areas sheet 1 — 24x36" 2 05/23/07 DW -3 Drainage Areas and Built Upon Areas sheet 2 — 2406" 2 05/23/07 DWQ-4 Layout and Road Stationing sheet 1 — 2406" 2 05/23/07 DWQ-5 Layout and Road Stationing sheet 2 — 2406" 2 05/23/07 UT-1 Stormwater Collection, Infiltration, and Bypass System sheet 1 — 2406" 2 05/23/07 UT-2 Stormwater Collection, Infiltration, and Bypass System sheet 2 — 2406" 2 05/23/07 SEC-1 Infiltration Sections sheet 1 — 2406" 2 05/23/07 Infiltration Sections sheet 2 — 24x36" 2 05/23/07 Infiltration Sections — 24x36" 2 05/23/07 RSEC-2 Details sheet 1 — 24x36" 2 05/23/07 Details sheet 2 — 24x36" 2 05/23/07 Stormwater Pump Station Typical Plans and Section — 2406" 1 06/15/2007 - Stormwater Management Permit Application Report Section 2.0, Sealed 6-15-2007 1 05/23/07 - Stormwater Management Permit Application Report Cover Sheet, Sealed 5-23-2007 1 06/15/2007 - Stormwater Management Permit Application Comment Response Letter THESE ARE TRANSMITTED as checked below: [ ] For approval [ ] Approved as submitted [ ] Resubmit copies for approval [ ] For your use [ ] Approved as noted [ ] Submit copies for distribution [ ] As requested [ ] Returned for corrections [ ] Return ie1 31T D [x] For review and comment J U N 1 8 7 n n 7 [ ] FOR BIDS DUE [ ] PRINTS RETURNEDLMtR r (1AN Tn 1TS REMARKS: Please find enclosed documents in response to your request for more information. The only revision to the plan set was the addition of the engineer's seal on the cover sheet. Thank you for your consideiatiori of this material. Please call with any questions, (919) 854-4373. COPY TO: File SIGNED: � Reuben S. ifnes III If enclosures are not as noted, kindly notify us at once. Milone & MacBroom, Inc., 5511 Capital Center Drive, Suite 106, Raleigh, North Carolina 27606, Tel.(919) 854-4373, Fax. (919) 854-4393 G:\sdskproj\2041-38\Correspondence\Transmittals\2007 06 15 DENR DWQ SUBMISSION REV.doc Engineering, Landscape Architecture and Environmental Science �0 MILONE & MACBROOMm June 15, 2007 Mr. Chris Baker N.C. Department of Environment and Natural Resources Water Quality Section Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, North Carolina 28405 RE: Waterway Cove Dear Mr. Baker, We received a copy of your review comments addressed to Mr. Kyle Corkum of Waterboro Village, LLC, dated June 12, 2007, concerning the above referenced project located on NC Highway 179/904 at SR 1232 within the Shallotte Township. We offer the following responses to each of your requirements and concerns: 1. Plans and calculations must have a P.E. seal, please correct. Response: Enclosed are sealed plans and the seal for the calculations. 2. The infiltration trench supplements Type "A, B, and C" call for a drainage area of 200 or 100. The trench data tables provided with the supplements must include the proper drainage area to be treated (probably the lot area) and the allowable built upon area per lot. Response: The infiltration trench supplement tables were updated to include the drainage area and built upon area for each lot. 3. The trench data tables for Type "A, B, and C" show the # sign in the drainage area column. The drainage area must be reported in square feet, please correct. Response: The infiltration trench data tables were revised to show the drainage area in square feet. Thank you for the opportunity to provide the referenced revisions. Please contact us if additional information or clarification is needed to complete the review. Milone & MacBroom, Inc., 5511 Capital Center Drive, Suite 106, Raleigh, North Carolina 27606 (919) 854-4373 Fax (919) 854-4393 Very truly yours, Milone & MacBroom, Inc. 4e—uLb`enS.ones, II ,APE-^"R7 Branch Office Manager Enclosures ��� MILONE & MACBROOM Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen H. Sullins, Director Division of Water Quality June 12, 2007 Kyle Corkum, Manager Waterboro Village, LLC 5511 Captial Center Drive, Suite 105 Raleigh, NC 27606 Subject: Request for Additional Information Stormwater Project No. SW8 070544 Waterway Cove Brunswick County Dear Mr. Corkum: The Wilmington Regional Office received a Stormwater Management Permit Application for Waterway Cove on May 29,2007. A preliminary review of that information has determined that the application is not complete. The following information is needed to continue the stormwater review: Plans and calculations must have a P.E. seal, please correct. 2. The infiltration trench supplements Type "A,B,and C" call for a drainage area of 200 or 100. The trench data tables provided with the supplements must include the proper drainage area to be treated (probably the lot area) and the allowable built upon area per lot. 3. The trench data tables for Type"A,B,and C" show the # sign in the drainage area column. The drainage area must be reported in square feet, please correct. Please note that this request for additional information is in response to a preliminary review. The requested information should be received by this Office prior to June 19, 2007, or the application will be returned as incomplete. The return of a project will necessitate resubmittal of all required items, including the application fee. If you need additional time to submit the information, please mail or fax your request for a time extension to the Division at the address and fax number at the bottom of this letter. The request must indicate the date by which you expect to submit the required information. The construction of any impervious surfaces, other than a construction entrance under an approved Sedimentation Erosion Control Plan, is a violation of NCGS 143-215.1 and is subject to enforcement action pursuant to NCGS 143-215.6A. Please reference the State assigned project number on all correspondence. Any original documents that need to be revised have been sent to the engineer or agent. All original documents must be returned or new originals must be provided. Copies are not acceptable. If you have any questions concerning this matter please feel free to call me at (910) 796-7304. Sincerely, Chris Baker Environmental Engineer II ENB/csb: S:IWQSISTORMWATERIADDINF0120071070544.jun07 None pithCarolina cc: Reuben Jones, Milone and Macbroom, Inc. Naturally North Carolina Division of Water Quality 1617 Mail Service Center Raleigh, NC 21699-1617 Phone (919) 733-7015 Customer Service Internet: www.ncwaternualiiy.org Location: N. 512 Salisbury St. Raleigh, NC 27604 Fax (919) 733-2496 1-877-623-6748 An Equal OpportunitylAffirmative Action Employer— 50% Recycled110% Post Consumer Paper iNFit i KATION SITE VISIT REQLUE Name of the Project: Py ca i- 1' Location (attach a clear vicinity map Directions from the nearest major ilr MAW 61, WCL.--f A.-; Owner/Applicant Name: �. herd (/(•llR� ¢� Street address, SR number, community, etc. �cfion: s e =ti G U P—o n . r. C Consultant Name:v �..� _ ; %✓c t �� �, s Consultant Contact Information: -' S/ S"2 —o e r) Phoge, fa}C, email, etc. t " — #1 #2 #3 94 #5 #I i Existing ground elev. @basin/trenchi SHWT elev.= SHWT plus 2' (max. bottom elev.)= I Date/Time of Soils Investigation : / 0 7 S. • Summarv/Comments: %ti0 AS, All proposed infiltration areas and existing, dative utility lines located within the proposed basin/trench must.be marked and flagged. If these areas ire not flagged, the Soils Scientist reserves the right to decline to do the investigation. If the proposed infiltration system will be located in an area of existing pavement and there is no open area nearby, bquipment capable of breaking through the impervious .Ja er.must.bc Provided. The soils investi atiuh does not take the l2lace of a soils rep ort prepared b an appropriate professional. The Soils Scient;st will only verify the soil conditions that are reported in the Soils Report, and make a determination as to the suitability of the site to meet the infiltration design requirements under NCAC 2H.10010, and assumes no liability should the system fail. i I I a- d 0900asir0 T s ou i dnojq -4uaws2eueW puel e9*:s0 GO IT petal Jun 12 07 09:20a Land Management Group Inc 9104520060 p.2 ALMG LAND MANAGEMENT GROUP INC. Environmental Consultants June 12, 2007 Troy Ni De%ven L mdquest Development 5511 Capital Center Dr. Suits 105 Raleigh, NC 27606 Reference: Stormwater infiltration study for the proposed Waterboro Development near Ocean Me, NC. Dear Mr. DeHaven: On Wednesday June 6, 2007, Land Manageament Group, Inc. had the pleasure of evaluating the proposed stormwater infiltration areas at the proposed Waterboro development site. The purpose of the evaluation was to describe the soil profile, quantify the depth to the seasonal high water table, using 5 foot soil auger borings, and to inform the project engineer of any potential limitations of this project. Actual hydraulic conductivity measurements were not taken. Therefore, my report will focus on suggested infiltration rates from the NC DENR DWQ representative. The soils at this site are mapped as Kureb and Wando soil series soils in the Soil Survey of Brunswick County (USDA,1986). Actual soil borings confirm the soil to be Wando Series in borings 15, 16, 21-30, and 32, Blanton Soil Series in boring 34 and a Leon soil series in boring 21 shown in Appendix A, the locations of the borings are shown in Appendix C. Borings 21 where unsuitable for stormwater infiltration, therefore my report will focus on the other suitable borings. The soil can best be described as deep sands that formed in a series of depositional events. It is expected that these soils will have high infiltration rate in excess of 4-10 in/hr. The seasonal high water table is normally evident by observation of redoximorphic features suggesting past conditions of saturation and reduction. There is evidence of redoximarphic features as shallow as 24" within one of the test borings of the proposed infiltration areas. 7n t ear borings - within the infiltration areas, the seasonal high water table was from 24" to 50" across the proposed test areas (see complete boring notes in Appendix A). No physical water levels were recorded on February 86. All recorded depths are from the existing surface as noted in the boring notes. The official published description and physical and chemical data for the Wando soil series are shown in Appendix B for comparison. www.lmgroup.net • in€o6imgroup. net • Phone: 910.452.0001 • Fax: 910.452.0060 3805 Wrightsville Ave., Suite 15, Wilmington, NO 28403 • P.O. Box 2522, Wilmington, NO 28402 Jun 12 07 09:20a Land Management Group Inc 9104520060 p.3 In summary, LMG has performed site specific evaluation within the stormwater zn—filtration are~. This area has sail's that have a, seasons; high water: tale t1&4- are 24 inches in boring 16 the other areas that have seasonal high water tables from 27 inches in borings 23 and 30, to 50 inches in borings 15 and 32 from the soil surface and an infiltration rate of up to 10 inches per hour. All notes for installation and limitations to proposed basin areas are mentioned in Appendix A, as per NC DENR representative. Please do not hesitate to contact me if you have any questions with this report. I may be reached at 910452-0001, 910-471-0505 or at nhowe11Cu71msroup.net . Sincerely, Nick Howell Environmental Scientist CC: Ruben Jones Jun 12 07 09:20a Land Management Group I-nc 9104520060 p.4 Appendix A Soil Boring Notes and Design Criteria Jun 12 07 09:22a Land Management Group Inc 9104520060 p. 15 Waterboro Tract Stormwater Evaluation Test Area Map f Origional Mapped Line ---. Newly Edited Line Q Test Location Lwo Oak Ava. 40' R\x Ali **Map Provided 6y Others** **Map Not To Scale** Jun 12 07 09:20a Land Management Group Inc 9104520060 p.5 Soil Boring Notes GPS Test Locations 6/6/2007 *Seasonal High Water Table: *Infiltration Rate in/hr: Notes as stated by Vincent Lewis: 15 W1 8 to 10 16 24" 6 to 8 21 Unsuitable NA 22 40" 6 to 8 23 2T' 6 to 8 30 2T' 6 to 8 32 W4 8 to 10 34 30" 4 or 6 to 8 Infiltration rate will be 4 in/hr if the trench bottoms are installed any deeper than 1 foot from the natural surface due to a coarse loamy layer that forms Q -24" * Values for rates and water table depth as stated by Vincent Lewis Engine ft Landscape Awhitemm andEnvinmmental Science O* MILONE &MACBROOM TO NC DENR, Wilmington Regional Office Division of Water Quality 127 Cardinal Drive Extension Wilmington, NC 28405 LETTER OF TRANSMITTAL Date: 05/25/07 Job No. 2041-38 Attention: Chris Baker RE: Waterway Cove Title Sheet for Stormwater Management Plan Set WE ARE SENDING YOU Q Attached [ ] Under separate cover via UPS the following items: [ ] Shop Drawings 0 Prints [ ] Plans . [ ] Samples [ ] Specifications [ ] Copy of Letter [ ] Change Order [ ] Copies Date No. Description 2 05/23/07 - Title Sheet for Waterway Cove Stormwater Management Plan Set 24x36" THESE ARE TRANSMITTED as checked below: [ ] For approval [ ] Approved as submitted [ ] Resubmit copies for approval [ ] For your use [ ] Approved as noted [ ] Submit copies for distribution [ ] As requested [ ] Returned for corrections [ ] Return corrected prints [ J For review and comment [x] For use with Stormwater Management Plan Set / Permit Application, delivered Friday 5/25/07 [ ] FOR BIDS DUE [ ] PRINTS RETURNED AFTER LOAN TO US REMARKS: Please find enclosed sealed, signed, and dated title sheets for stormwater management plan set as described above. Thank you for your consideration of this material. Please call with any questions, (919) 8544373. COPY TO: File Troy Dehaven — LQ SIGNED: s. Reuben S. Jones III if enclosures are not as noted, kindly notify us at once. Milone & MacBroom, Inc., 5511 Capital Center Drive, Suite 106, Raleigh, North Carolina 27606, Tel.(919) G:\sddMiro \2041-38\Correspondence\Transmittals\2007 05 25 DENR DWQ title sheet-rev.doc MAY 2 9 2007 Fax. (919) 854-4393 Engineering, Landscape Archit ,awe and Emlronmmwl Science MILONE & MACBROOM r 7BY: Y 2 5 `'001 -- R OF TRANSMITTAL 'TO NC DENR, Wilmington Regional Office Division of Water Quality Date: 05/25/07 1 Job No. 2041-38 Attention: Chris Baker RE: Waterway Cove Stormwater Management Permit Application WE ARE SENDING YOU [] Attached Under separate cover via UPS the following items: [ ] Shop Drawings [ ] Prints 0 Plans [ ] Samples [ ] Specifications [ ] Copy of Letter [ ] Change Order [ ] Copies Date No. Description 2 05/23/07 - Title Sheet for Waterway Cove Stormwater Management Plan Set 24x36" 2 05/21/07 EX-1 Existing Conditions — 24x36" 2 05/23/07 DW -1 Overall Stormwater Management Plan — 2406" —Drainage 2 05/23/07 DW -2 Areas and Built Upon Areas sheet 1 — 24x36" 2 05/23/07 DWQ-3 Drainage Areas and Built Upon Areas sheet 2 — 2406" 2 05/23/07 DWQ-4 Layout and Road Stationingsheet 1 — 24x36" 2 05/23/07 DWQ-5 Layout and Road Stationingsheet 2 — 24x36" 2 05/23/07 UT-1 Stormwater Collection Infiltration, and Bypass S stem sheet A2406" 2 05/23/07 UT-2 Stormwater Collection, Infiltration, and Bypass S stem sheet 2 05/23/07 SEC-1 Infiltration Sections sheet 1 — 2406" 2 05/23/07 SEC-2 _ Infiltration Sections (sheet 2) —24x36" 2 05/23/07 SEC-3 Infiltration Sections — 2406" 2 05/23/07 SD-1 Details Csheet 1 — 2406" 2 05/23/07 SD-2 Details sheet 2 — 2406" 2 05/23/07 PS-1 Stormwater Pump Station Typical Plans and Section — 24x36" 1 05/23/07 - Waterwa Cove Stormwater management Permit A lication and RAort 1 05/24/07 1022 Check to NC DENR for $4000.00 for express permitting THESE ARE TRANSMITTED as checked below: [ ] For approval [ ] Approved as submitted [ ] Resubmit copies for approval [ ] For your use [ ] Approved as noted [ ] Submit copies for distribution [ ] As requested [ ] Returned for corrections [ ] Return corrected prints [x] For review and comment [ ] FOR BIDS DUE [ ] PRINTS RETURNED AFTER LOAN TO US REMARKS: Please find enclosed documents for application for a stormwater management permit as described above. Thank you for your consideration of this material. Please call with any questions, (919) 854-4373. COPY TO: File Troy Dehaven — LQ SIGNED: 1L, '�' Reuben S. Jones I If enclosures are not as noted, kindly notify us at once. Milone & MacBroom, Inc., 5511 Capital Center Drive, Suite 106, Raleigh, North Carolina 27606, Tel.(919) 854-4373, Fax. (919) 854-4393 G:lsdskproj12041-331CorrespondencelTransmitmis12007 05 25 DENR DWQ SUBMISSION.doc Engineering, Landscape Architecture and Environmental Science ��� MILONE & MACBROOM® May 22, 2007 Mr. Chris Baker N.C. Department of Environment and Natural Resources Water Quality Section Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, North Carolina 28405 Re: Stormwater Permit Application Waterway Cove Subdivision Brunswick County, North Carolina MMI No. 2041-38 Dear Mr. Baker: On March 22nd we met with yourself and Cameron Weaver of your office for a pre - application meeting. It was determined that the proposed project was eligible for the express review program. We appreciate your input at that time and following. We have developed a plan which is fundamentally consistent with the approach described at pre -application meeting. We trust the system described herein is consistent with the applicable regulations. If clarification or additional information is needed, please do not hesitate to contact us. Very truly yours, MILONE & MACBROOM, INC. Reuben S. Jones III, P.E. Branch Office Manager Milone & MacBroom, Inc., 5511 Capital Center Drive, Suite 106, Raleigh, North Carolina 27606 (919) 854-4373 Fax (919) 854-4393 INFILTRATION SITE VISIT REQUEST ' S Name of the Pro.iect 'T�0.�o',�o�1 Location (attach a clear vicinity map): 'Se. ` Street address, SR number, community, etc. Directions from the nearest major intersection: �i �N; Y-, ;,\ Owner/Applicant Name: Consultant Name: Consultant Contact Information:11) ci - 14 ) N • `Vj `-) ) cam-- b Coo Phone, fax, email, etc. —t �: s 11 ice-. + 5 �;,) r,•� �cto.� () • ��� #1 #2 #3 #4 #5 46 #7 48 Existing ground elev. @basin/trench= SHWT elev.= SHWT plus 2' (max. bottom elev.)= Date/Time of Soils Investigation : 2%FJL�/� $ ; 3 t) Summary/Comments: All proposed infiltration areas and existing, active utility lines located within the proposed basin/trench must be marked and flagged. If these areas are not flagged, the Soils Scientist reserves the right to decline to do the investigation. If the proposed infiltration system will be located in an area of existing pavement and there is no open area nearby, equipment capable of breaking through the impervious .Jayer must be provided. The soils investigation does not take the place of a soils report prepared by an appropriate professional. The Soils Scientist will only verify the soil conditions that are reported in the Soils Report, and make a determination as to the suitability of the site to meet the infiltration design requirements under NCAC 2H.1000, and assumes no liability should the system fail. �}� rlj<--3, ' C—S)C,OQ� '1300ridari'.-s are approximate and are"' not rnevnt to be absolute. S UP Map Source: North Carolina Atlas & Gazetteer. Pg MML 2003 Troy M. DeHaven Waterboro 49.01 Acres LM G f .�4 NT LAND NWAGIUNIEGROUP i,- Brunswick County, NC Eovi'opmenrul Conwitonri 30-07-032 w January 2007 N SCALE 1" = 1 Mile Figure I Vicinity Map i 11 t f z • I � � 5 r ' •may (c, � 1 .'� � �>ti•' f 1!•- t - (f1,511rd'>ni _ �, �/ , `, '� �, + _,—:- , i w.XG•.-..��j f � "1` .� -'^+.,79\, t _ __._-...� • i ti, � i ,�: as " . • 4 s lY i r •1 tI % #( j -. f l Is 1', c7C4 �a - • R -- � I � 1 l *Bounder;es 4."e app;o;'rm•nate and area " SFE not rtie?nt to be L b,3oluie. Map Source: Shallotte Quadrangle 7.5 minute (topographic) 1990. Troy M. DeHaven LIG Waterborc 49.01 Acres Brunswick County NC LAN DALANAGIMGIVTGAUUP ..: 1 [Il Vlrr111111 F11rOf Coll.s UffJ lift/ 30-07-032 January 2007 N W+E S SCALE V = 2000` Figure 2 USGS Topgraphic Map