Loading...
HomeMy WebLinkAboutNCS000064_Renewal application_20221004September 30, 2022 Brianna Young 1612 MSC Raleigh, NC 27699-1612 via e-mail: brianna.young0ncdenr.gov RE., Individual Stormwater Permit Renewal App//cation CNA Ho/dings, LLC - Shelby NPDES Permit No. NCS000064 Dear Ms. Young: Celanese .. _ .-an-istr; inu:ae iIr. s:=;ion Celanese Corporation 222 W. Las Colinas Blvd. Suite 90ON Irving, Texas, USA 75039 www.cetanese.com RECEIVED DEMLR-Stormwater Program CNA Holdings, LLC (CNA Holdings) owns and operates a facility in Grover, NC (the Shelby Plant). The facility currently operates under Permit No. NCS000064 that allows discharge of stormwater under the National Pollutant Discharge Elimination System (NPDES). The current permit was effective starting on April 9, 2018 and expires on March 31, 2023. CNA Holdings is submitting this permit application to request renewal of the permit within 180 days of the expiration of the permit (or by October 3, 2022) as required. Consistent with North Carolina Department of Environmental Control (NC DEQ) instructions, one hard copy of the required forms and supporting documents are included in this submittal, with two copies of supported documentation included. The attached forms and supporting documents will also be e-mailed to your attention. If you have any questions concerning the information in the permit application, please contact me at 704- 480-5759 or Jen Wheat of Trinity Consultants at (704) 553-7747. Sincerely, CNA �HOLDIN L^C � 4 F-_ Eric John n ESH Manager cc: Ms. Jennifer Wheat, Trinity Consultants Inc. Attachment 1 Application Forms ► EPA Form 1 P. EPA Form 2F ► NC DEQ Supplemental Information Form ► NC DEQ SPPP Certification Form EPA Identification Number NPDES Permit Number FaciCty Name Form Approved 03105119 110001503105 NCS000064 CNA Holdings LLC - Shelby OMB No. 2040-0004 Form U.S. Environmental Protection Agency 1 EPA Application for NPDES Permit to Discharge Wastewater NPDES GENERAL INFORMATION SECTION REQUIRING .D,0 1.1 Applicants. Not Required to Submit Form 1 1.1.1 Is the facility a new or existing publicly owned 1.1.2 Is the facility a new or existing treatment works treatment works? treating domestic sewage? If yes, STOP. Do NOT complete 0 No If yes, STOP. Do NOT No Form 1. Complete Form 2A. complete Form 1. Complete Form 2S. 1.2 Applicants Required to Submit Form 1 1.2.1 Is the facility a concentrated animal feeding 1.2.2 Is the facility an existing manufacturing, operation or a concentrated aquatic animal commercial, mining, or silvicultural facility that is a. production facility? currently discharging process wastewater? oYes 4 Complete Form 1 0 No 0 Yes -* Complete Form 0 No a and Form 213. 1 and Form 2C. C 1.2.3 Is the facility a new manufacturing, commercial, 1.2.4 Is the facility a new or existing manufacturing, mining, or silvicultural facility that has not yet commercial, mining, or silvicultural facility that = commenced to discharge? discharges only nonprocess wastewater? Cr 0 Yes 4 Complete Form 1 ✓0 No 0 Yes 4 Complete Form 0 No and Form 2D. 1 and Form 2E. .2 1.2.5 Is the facility a new or existing facility whose •,� discharge is composed entirely of stormwater A associated with Industrial activity or whose discharge is composed of both stormwater and non-stormwater? 0✓ Yes 4 Complete form 1 0 No and Form 2F unless exempted by 40 CFR 122.26(b)(14)(x) or b 15 . SECTION 2. NAME, MAILING ADDRESS, • • i CFR 2.1 Faciti" . Name _.. CNA Holdings LLC - Shelby 0 2.2 EPA Identification Number 0 110001503105 R 2.3 Facility Contact .1 Name (first and last) Title Phone number V Eric Johnson EHS Manager (704) 480-5759 Email address EriclJohnson@celanese.com m 2.4 Facillt Valling Address zStreet or P.O. box 2525 Blacksburg Road City or town State ZIP code Grover NC 28073 EPA Form 3510-1(revised 3-19) Page 1 EPA Identification Number NPDES Permit Number Facility Name Form Approved 03105/19 110001503105 1 CNA Holdings LLC- Shelby OMB No. 2040-0004 „ d 2.5 Facility Location o a Street, route number, or other specific identifier 4 V 2525 Blacksburg Road rn `o County name County code (if known) Cleveland 0 6 City or town State ZIP code z A Grover NC 28073 SECTION•r r 3.1 SIC Code(s) Description (optional) 2821 PLASTICS MATERIALS, SYNTHETIC RESINS, AND NONVULCANIZABLE ELASTOMERS N GI U O U N U z 3.2 NAICS Code(s) Description (optional) a c v 325211 PLASTICS MATERIAL AND RESIN MANUFACTURING Name of Operator 4.1 CNA Holdings LLC Taq 4.2 Isthe name you listed in Item 4.1 also the owner? Yes ❑ No 4.3 0 erator Status ❑ Public —federal ❑ Public —slate ❑ Other public (specify) o ❑� Private ❑ Other (specify) 4.4 Phone Number of Operator (704)480-5800 4.5 Operator Address Street or P.O. Box E 2525 Blacksburg Road o � .w City or town State ZIP code `o o Grover NC 28073 � U � o Email address of operator lawrence.wolnlck@celanese.com SECTION• 'r A a 5.1 Is the facility located on Indian Land? ❑ Yes ID No EPA Form 3510.1 (revised 3-19) Page 2 EPA Identification Number NPDES Permit Number Facility Name Form Approved 03105/19 110001503105 NCS000064 CNA Holdings LLC- Shelby OMB No. 2040-0004 SECTION• I 6.1 Existing Environmental Permits (check all that apply and print or type the corresponding permit number for each) m m NPDES (discharges to surface m RCRA (hazardous wastes) ❑ UIC (underground injection of water) fluids) P E NC0004952 NCDO03446721 w` a ❑ PSD (air emissions) ❑ Nonallainment program (CAA) NESHAPs (CAA) c Synthetic Minor 03754R57 x ❑ Ocean dumping (MPRSA) ❑ Dredge or fill (CWA Section 404) ❑ Other (specify) w SECTION 1 7.1 Have you attached a topographic map containing all required information to this application? (See instructions for a specific requirements.) f ✓❑ Yes ❑ No ❑ CAFO—Not Applicable (See requirements in Form 2B.) SECTIONOF 1 8.1 Describe the nature of your business. Liquid crystal polymer production c m 0 m 9 m z SECTION•• I 9.1 Does your facility use cooling water? d ❑✓ Yes ❑ No + SKIP to Item 10.1. A a 9.2 Identify the source of cooling water. (Note that facilities that use a cooling water intake structure as described at 0 2 40 CFR 125, Subparts I and J may have additional application requirements at 40 CFR 122.21(r). Consult with your c Y NPDES permitting authority to determine what specific information needs to be submitted and when.) 02 c Public water system SECTION1 VARIANCE REQUESTS41 1 10.1 Do you intend to request or renew one or more of the variances authorized at 40 CFR 122.21(m)? (Check all that apply. Consult with your NPDES permitting authority to determine what information needs to be submitted and u when.) v ❑ Fundamentally different factors (CWA ❑ Water quality related effluent limitations (CWA Section Section 301(n)) 302(b)(2)) ❑ Non -conventional pollutants (CWA ❑ Thermal discharges (CWA Section 316(a)) Section 301(c) and (g)) ❑✓ Not applicable EPA Form 3510.1 (revised 3-19) Page 3 EPA Identification Number NPDES Permit Number Facirdy Name Form Approved 03PoS119 110001503105 NCS000064 CNA Holdings LLC -Shelby OMB No. 2040-0004 SECTION• 1 11.1 In Column 1 below, mark the sections of Form 1 that you have completed and are submitting with your application. For each section, specify in Column 2 any attachments that you are enclosing to alert the permitting authority. Note that not all applicants are required to provide attachments. Column 1 Column 2 ❑✓ Section 1: Activities Requiring an NPDES Permit ❑ w/ attachments ❑✓ Section 2: Name, Mailing Address, and Location ❑ w/ attachments Section 3: SIC Codes ❑ w/ attachments ❑� Section 4: Operator Information ❑ w/ attachments ❑ Section 5: Indian Land ❑ wl attachments c Section 6: Existing Environmental Permits ❑ wl attachments d ❑✓ Section 7: Map ❑laopographic ❑ wl additional attachments in o ❑� Section 8: Nature of Business ❑ w/ attachments w ❑� Section 9: Cooling Water Intake Structures ❑ wl attachments r �' ❑� Section 10: Variance Requests ❑ w/ attachments a ❑ Section 11: Checklist and Certification Statement ❑ wl attachments s d 11.2 Certificatton Statement U 1 certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel propedy gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are signficant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations. Name (print or type first and last name) Official title Lawrence Wolnik Site Director Signature Date signed AAAu Y _4a -ZDZZ EPA Forth 3510-1 (revised 3-19) Page 4 EPA Identification Number NPDES Permit Number Facility Name Form Approved 03/05/19 110001503105 NCS000064 CNA Holdings LLC - Shelby OMB No. 2040-0004 Form U.S Environmental Protection Agency 2F V01 EPA Application for NPDES Permit to Discharge Wastewater NPDES STORMWATER DISCHARGES ASSOCIATED WITH INDUSTRIAL ACTIVITY SECTION OUTFALL LOCATION - 1.1 Provide information on each of the facilit Is outfalls in the table below Outfall Receiving Water Name Latitude Longitude Number EAST Buffalo Creek 350 12' 30" N 810 31 25" W c 0 it NORTH Buffalo Creek 350 12 40" N 81° 31 30" W 0 J SOUTH Buffalo Creek 350 11 51" N 810 31' 47" W O 0 ! " 0 , „ 0 „ 0 , •, 0 SECTION•-• .0 2.1 Are you presently required by any federal, state, or local authority to meet an implementation schedule for constructing, upgrading, or operating wastewater treatment equipment or practices or any other environmental programs that could affect the discharges described in this application? ❑ Yes 0 No 4 SKIP to Section 3. 2•2 Briefly identify each applicable project in the table below. Brief Identification and Affected Outfalls Final Compliance Dates Description of Project (rut outlall numbers) Source(s) of Discharge Required Projected m m a E 2.3 Have you attached sheets describing any additional water pollution control programs (or other environmental projects that may affect your discharges) that you now have underway or planned? (Optional Item) ❑ Yes ❑ No EPA Form 3510-2F (Revised 3-19) Page 1 EPA Identification Number NPDES Permit Number Facility Name Form Approved 03/05119 110001503105 NCS000064 CNA Holdings LLC - Shelby OMB No. 2040-0004 SECTION 3. SITE DR r 3.1 Have you attached a site drainage map containing all required information to this application? (See instructions for specific guidance.) o ® Yes ❑ No POLLUTANTSECTION 4. e I 4.1 Provide information on the facility's pollutant sources in the table below. Outfall Impervious Surface Area Total Surface Area Drained Number (within a mile radius of the facility) (within a mile radius of the facility) specifyunits specify units EAST 20.5 acres 21.7 acres speclry units specify units NORTH 36.2 acres 40.81 acres specify units specify units SOUTH 15.3 acres 31.5 acres specify units specify units specify units specdyunits specify units specify units 4.2 Provide a narrative description of the facility's significant material in the space below. (See instructions for content requirements.) See attachment N d U A C m O a 4.3 Provide the location and a description of existing structural and non-structural control measures to reduce pollutants in stormwater runoff. See instructions fors specificguidance.) Stormwater Treatment Codes Outfall from Control Measures and Treatment Exhibit Number 2F-1 (list) North Bi weekly inspections, training, SWPP, semi-annual inspections, secondary containment N/A South BI weekly inspections, training, SWPP, semi-annual Insp., roofs (cover), secondary cant. N/A East BI weekly insp., training, SWPP, semi-annual insp., unloadinglloading processes, sec. cant. N/A EPA Form 3510-2F (Revised 3-19) Page 2 EPA Form 2F — Attached Information Section 4.2 Response: Significant materials include: loading and unloading docks, scrap metal storage areas, oil and chemical tank farm areas, solid waste compactors and dumpsters, recycling areas, wastewater treatment and hazardous and non -hazardous areas. The north outfall includes compounding and Vectra waste dumpster roll -offs, cardboard and scrap metal recycling, brown & root scrap yard, oil & chemical storage with secondary containment, emergency firewater basin, HOA secondary containment basin and a cooling tower. There are two storage tanks, 5,000 gallons capacity each, of Therminol 66 which is diked. The south outfall contains a number 6 empty closed in place AST, a gasoline and diesel unloading/loading station (under roof), hazardous and non -hazardous storage (under roof), and a cooling tower tank farm (empty and clean, abandoned in place). There is a 50,000 gallon tank of acetic anhydride, a 50,000 gallon tank of acetic acid, a 30,000 gallon tank of triethylene glycol, a 30,000 gallon tank of spent glycol, and a 10,000 gallon tank of ethylene glycol. These are in stainless steel tanks in a diked area. The hazardous and non -hazardous are currently has sodium hydroxide 300 and corrosion inhibitor for the process water tank. There is also a waste holding pad in the south. The east outfall includes loading and unloading of raw materials and by/co-products, Marley cooling tower. The raw materials and by/co products include 300 gallon of caustic, 120 gallon of boiler treatment, 120 gallon of oxygen scavenger, 120 gallon of corrosion inhibitor, 120 gallon of bromine, 120 gallons of biocide, and 120 gallons of coiling tower treatment. These are in totes and stored in the building. Approximately 80 gallons of "Roundup" is used each year throughout the plant site on edging, around cooling towers, transformers, wastewater basins & railroad tracks as a grass and weed killer. The use of "Ice Melt" is limited to sidewalks and pedestrian walkways when inclement weather conditions require its use. EPA Identification Number NPDES Permit Number Facility Name Form Approved 03/05/19 110001503105 NCS000064 CNA Holdings LLC - Shelby OMB No. 2040-0004 SECTION•N STORMWATER • 1 5.1 1 certify under penalty of law that the outfallls) covered by this application have been tested or evaluated for the presence of non-starmwater discharges. Moreover, I certdy that the outfalls identified as having non-stormwater discharges are described in either an accompanying NPDES Form 2C, 2D, or 2E application. Name (print or type first and last name) Official title Lawrence Wolnick Site Director Signa re Date signed N I 5.2 Provide the testing information requested in the table below. O Onsite Drainage Points v o Number Description of Testing Method Used Date(s) of Testing Directly Observed During Test m 3 North Observation, SW PP review, site plan review 09/28/2022 Catch basins, drains, t_ swales and outfall 0 N c South Observation, SW PP review, site plan review 9/28/2022 Catch basins, drains, o z swales and outfall East Observation, SWPP review, site plan review 9/28/2022 Catch basins, drains, swales and outfall SECTIONOR 1 Describe any significant leaks or spills of toxic or hazardous pollutants in the last three years. 6.1 2 a. No significant leaks or spills of toxic or hazardous pollutants in the last three years. w `o e u C c M SECTION DISCHARGE INFORMATION41 instructions to determine the pollutants and parameters you are required to monitor and, in turn, the tables you must See the c com lets. Not all applicants need to complete each table. 7.1 Is this a new source or new discharge? `o ❑ Yes 4 See instructions regarding submission of ❑ No + See instructions regarding submission of 1 = estimated data. actual data. v Tables A, B, C, and D 7.2 Have you completed Table A for each outfall? ❑✓ Yes ❑ No EPA Farm 3510-21' (Revised 3-19) Page 3 EPA Identification Number NPDES Permit Number Facirdy Name Form Approved 03/05/19 110001503105 NCS000064 CNA Holdings LLC - Shelby OMB No.2040-M 7.3 Is the facility subject to an effluent limitation guideline (ELG) or effluent limitations in an NPDES permit for its process wastewater? ❑✓ Yes ❑ No 4 SKIP to Item 7.5. 7.4 Have you completed Table B by providing quantitative data for those pollutants that are (1) limited either directly or indirectly in an ELG and/or (2) subject to effluent limitations in an NPDES permit for the facility's process wastewater? 0 Yes ❑ No 7.5 Do you know or have reason to believe any pollutants in Exhibit 2F 2 are present in the discharge? ❑ Yes ❑✓ No 4 SKIP to Item 7.7. 7.6 Have you listed all pollutants in Exhibit 2F-2 that you know or have reason to believe are present in the discharge and provided quantitative data or an explanation for those pollutants in Table C? ❑ Yes ❑ No 7.7 Do you qualify for a small business exemption under the criteria specified in the Instructions? = ❑ Yes +SKIP to Item 7.18. ✓❑ No 7.8 Do you know or have reason to believe any pollutants in Exhibit 2F-3 are present in the discharge? ❑ Yes ❑ No 4 SKIP to Item 7.10. 7.9 Have you listed all pollutants in Exhibit 2F-3 that you know or have reason to believe are present in the discharge in 3 Table C? o� = ❑ Yes ❑ No 7.10 Do you expect any of the pollutants in Exhibit 2F-3 to be discharged in concentrations of 10 ppb or greater? ❑ Yes ❑ No SKIP to Item 7.12. 7.11 Have you provided quantitative data in Table C for those pollutants in Exhibit 2F-3 that you expect to be discharged in concentrations of 10 ppb or greater? ❑ Yes ❑ No 7.12 Do you expect acrolein, acrylonitrile, 2,4-dinitrophenol, or 2-methyl4,6-dinitrophenol to be discharged in concentrations of 100 ppb or greater? ' ❑ Yes ❑ No 4 SKIP to Item 7.14. .,°.. n 7.13 Have you provided quantitative data in Table C for the pollutants identified in Item 7.12 that you expect to be , discharged in concentrations of 100 ppb or greater? ❑ Yes ❑ No 7.14 Have you provided quantitative data or an explanation in Table C for pollutants you expect to be present in the ` discharge at concentrations less than 10 ppb (or less than 100 ppb for the pollutants identified in Item 7.12)? ❑ Yes ❑✓ No < 7.15 Do you know or have reason to believe any pollutants in Exhibit 2F-4 are present in the discharge? ❑ Yes © No 4 SKIP to Item 7.17. 7.16 Have you listed pollutants in Exhibit 2F4 that you know or believe to be present in the discharge and provided an explanation in Table C? ❑ Yes ❑ No 7.17 Have you provided information for the storm event(s) sampled in Table D? ~ ❑ Yes El No EPA Form 3510-217 (Revised 3-19) Page 4 EPA Identification Number NPOES Permit Number Facility Name Form Approved 03105/19 110001503105 NCS000064 CNA Holdings LLC - Shelby OMB No.2040.000<t Used or Man factuiretl Toxics 7.18 Is any pollutant listed on Exhibits 2F-2 through 2F-4 a substance or a component of a substance used or manufactured as an intermediate or final product or byproduct? ' ❑ Yes ❑✓ No 4 SKIP to Section 8. 7.19 List the pollutants below, including TCDD if applicable. 1. 4. 7. 2. 5. 8. o. 3. 6. 9. SECTIONBIOLOGICAL T• DATA .0 CFR Do you have any knowledge or reason to believe that any biological test for acute or chronic toxicity has been made on 8.1 any of your discharges or on a receiving water in relation to your discharge within the last three years? o: "'' ' ❑ Yes ✓❑ No + SKIP to Section 9. �-- 8.2 Identify the tests and their purposes fY p p below. Tests) Pu�ase aT�est(sj j Subm.�jiy}�tyyed �ojjNjjPf?�5'✓ r ON' M j l �MYIQ Q $ bd ' t r i 0. ~' ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No SECTION• CONTRACT ANALYSIS INFORMATION41 Were any of the analyses reported in Section 7 (on Tables A through C) performed by a contract laboratory or ' 9.1 consulting firm? ❑ Yes ❑ No 4 SKIP to Section 10. `'. 9.2 Provide information for each contract laboratory or consulting firm below. tabaraotyketber'G ,Lebxafocy NumbrZ ' I borato�Nttt►ler�3 Name of laboratory/firm Waypoint Analytical (Formerly o Prism Laboratories) Laboratory address 449 Springbrook Road Charlotte, NC 28217 Phone number (704) 529-6364 Pollutant(s) analyzed I i TSS, BOD, COD, pH EPA Form 3510 2F (Revised 3-19) Page 5 EPA Identification Number NPDES Permit Number Facility Name Form Approved 03105119 110001503105 NCS000064 CNA Holdings LLC - Shelby OMB No. 2040-0004 SECTION 10. CHECKLIST AND CERTIFICATION STATEMENT (40 CFR 122.22(a) and (d)) 10.1 In Column 1 below, mark the sections of Form 2F that you have completed and are submitting with your application. For each section, specify in Column 2 any attachments that you are enclosing to alert the permitting authority. Note that not all applicants are required to com lete all sections or provide attachments. Column 1 Column 2' ❑� Section 1 ❑ wl attachments (e.g., responses for additional outfalls) ✓❑ Section 2 ❑ wl attachments ✓❑ Section 3 wl site drainage map ✓❑ Section 4 ✓❑ wl attachments ✓❑ Section 5 ❑ wl attachments ✓❑ Section 6 ❑ wl attachments r.• ` _ : ; ✓❑ Section 7 Table A ❑ wl small business exemption request ❑✓ Table B 0 wl analytical results as an attachment ❑ Table C ❑ Table D ✓❑ Section 8 ❑ wlattachments 4: ,,, ✓❑ Section 9 ❑ wlattachments (e.g., responses for additional contact laboratories or firms) ✓❑ Section 10 ❑ v := 10.2 Certification Statement I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine t. +l and imprisonment for knowing violations. Name (print or type first and last name) Official title Lawrence Wolnik Site Director Signature Date signed EPA Form 3510 2F (Revised 3-19) Page 6 EPA Idermfimfion Number NPDES Pemut Number Facility Name Form Approved 03105119 110001503105 NCS000064 CNA Holdings LLC- Shelby OMB No. 2040-0004 SECTIONr CHECKLIST AND CERTIFICATION STATEMENT (40 10.1 In Column 1 below, mark the sections of Form 2F that you have completed and are submitting with your application. For each section, specify in Column 2 any attachments that you are enclosing to alert the permitting authority. Note that not all applicants are required to com lete all sections or provide attachments. Column t Column 2 0 Section 1 ❑ wl attachments (e.g., responses for additional outfalls) El Section 2 ❑ wl attachments 0 Section 3 © wl site drainage map 0 Section 4 El wl attachments 0 Section 5 ❑ wl attachments 0 Section 6 ❑ wl attachments m ❑✓ Section 7 El Table A ❑ wl small business exemption request A c ❑� Table B ❑ wl analytical results as an attachment 0 ❑ Table C ❑ Table D r 0 ❑� Section 8 ❑ wlattachments v c y ❑� Section 9 ❑ wlattachments (e.g., responses for additional contact laboratories or firms) 32 _❑ Section 10 ❑ 10.2 Certification Statement I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel property gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system or those persons directly responsible for gathering the Information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations. Name (print or type first and last name) Official tille Lawrence Wolnik Site Director Signa a Date signed t w � %--�b -Z02Z RECEIVED DEMLR-Stormwater Program EPA Form 3510-21' (Revised 3-19) Page 6 Number I NPDES Permit Number 110001503105 I NC5000064 I CNA Holdings LLC- Shelby North Form Approved 03/05119 OMB No. 2040004 TABLE A. CONVENTIONAL AND NON CONVENTIONAL1 You must provide the results of at least one anal sis for every pollutant in this table. Complete one table for each outfall. See instruct ons for additional details and requirements. Pollutant or Parameter Maximum Daily Discharge (specify units) Average Daily Discharge (specify units) Number of Storm Events Sampled Source of Information (new source/new dischargers only, use codes in instructions) Grab Sample Taken During First 30Minutes Flow -Weighted Composite Grab Sample Taken During First 30Minutes Flow -Weighted Composite 1. Oil and grease N/A N/A 2. Biochemical oxygen demand (BODs) 13.4 mg/L 6.5 mg/L 8 3. Chemical oxygen demand (COD) 120 mg/L 40.4 mg/L 8 4. Total suspended solids (TSS) 57.6 mg/L 14.4 mg/L 8 5. Total phosphorus N/A N/A 6. Total Keldahl nitrogen (TKN) N/A N/A 7. Total nitrogen (as N) N/A pH (minimum) A6.6 8 6.pH(maximum) 7.4 Mg s 1 Sampling shall be conducted according to sufficiently sensitive test procedures (i.e., methods) approved under 40 CFR 136 for the analysis of pollutants or pollutant parameters or required under 40 CFR chapter I, subchapter N or 0. See instructions and 40 CFR 122.21(e)(3). EPA Form 3510-2F (Revised 3-19) Page 7 EPA Identification Number NPDES Permit Number Facility Name Outfall Number Form Approved 03/05/19 110001503105 NCS000064 CNA Holdings LLC - Shelby South OMB No. 2040-0004 TABLE• • / NON CONVENTIONAL•+'+ +1 You must provide the results of at least one anall sis for every pollutant in this table. Complete one table for each outW. See instructions for additional details and re uirements. M TNY sir m f'c �e A�eira �schi `eource �' - _.... • y N�m6erof,Storm= [nfr�Rn�tton Graib Sit ie ar«en, w kiirrsf F ; hf iG(�cQ Seim ieaEketr -x{y� Duritt Mist - :ftvw�INehte�` ((� tslt oPra>aer= ; . _ _g{ket -C�i6R.�i�i+f:Ni1�{RR Event;3 'Sampled �/������(�� dlsdta = = it Mitttiies = on use codes 16 Iminx ions) i Oil and grease N/A r .= Biochemical oxygen demand (BOD5) 5.3 mg/L 3.9 mg/L 8 �Y �1 =a Chemical oxygen demand (COD) < 50 mg/L < 50 mg/L 8 Total suspended solids TSS p � ) 31.9 mg/L 10 mg/L 8 Total phosphorus N/A N/A xii" r Total Kjeldahi nitrogen (TKN) N/A N/A Total nitrogen (as N) N/A N/A ' H minimum 6.6 8 pH (maximum) 7.4 6.9 8 J.: Samnlina shall be conducted according to sufficiently sensitive test procedures (i.e.. methods) approved under 40 CFR 136 for the analvsis of pollutants or pollutant parameters or required under 40 CFR chapter I, subchapter N or 0. See instructions and 40 CFR 122.21(e)(3). EPA Form 3510-217 (Revised 3-19) Page 7 EPA Identification Number NPDES Permit Number Facility Name Outfall Number Form Approved 03J05119 110001503105 NCS000064 CNA Holdings LLC - Shelby East OMB No. 2040-0004 TABLE A. CONVENTIONAL AND NON CONVENTIONAL• • You must provide the results of at least one anall sis for eve pollutant in this table. Complete one table for each outfall. See instructions for additional details and requirements. :... tMaximum Discharge Dal D w.erage.. fs atg Source.of t _� ,_ _.. utant-o I�uinber of Storm lnforma i n -- is ; _ t - - ;�cf 'Para stair z f !r m fib' ie Taksri FtawF' lei ftted :G i rah Satft Q'Fek h = FtOW4 0sghted E e is Sample rt►aauroe/new �€sdtarge�s use . - ` � 3D uritl;g�First- 3Q Minutes - Cot pcsite` Duifttg,First . 30"Minutes > Go �fe - only; codes in ki trucoons) Oil and grease N/A N/A Biochemical oxygen demand (BOD5) 6.5 mg/L 4.6 mg/L -8 Chemical oxygen demand (COD) 52 mg/L 28.4 mg/L 8 Total suspended solids (TSS) 48.2 mg/L 17.3 mg/L 8 .:: Total phosphorus N/A N/A Total K eldahl nitrogen TKN N/A N/A f,i7A'- ". Total nitrogen (as N) N/A N/A i pH (minimum) 7.3 8 :$:: pH (maximum) 8.2 7.6 8 Samnlina shall be conducted accordina to sufficierWv sensitive test procedures (i.e.. methods) approved under 40 CFR 136 for the analvsis of pollutants or pollutant parameters or required under 40 CFR chapter I, subchapter N or 0. See instructions and 40 CFR 122.21(e)(3). EPA Form 3510-2F (Revised 3-19) Page 7 EPA Identification Number 110001503105 NPDES Permit Number NCS0004952 Facility Name Out 4 Number CNA Holdings LLC - Shelby 001 Form Approved 03/05119 OMB No. 2040-0004 TABLE B. CERTAIN CONVENTIONAL AND NON CONVENTIONAL POLLUTANTS (40 CFR 122.26(c)(1)(i)(E)(4) and 40 CFR 122.21(g)(7)(vi)(A))' List each pollutant that is limited in an effluent limitation guideline (ELG) that the facility is subject to or any pollutant listed in the facility's NPDES permit for its process wastewater (if the facility is operating under an existing NPDES permit). Complete one table for each outfall. See the instructions for additional details and requirements. St L. 1.=: C;':: :7 . '' .' 7'•r1•`' 3- � !AV, tfawallab _FtawW'_ lilCal m.w h �, J ,r ? Eirent Sa>m led Source of 40 - _ rxew�aurow d�scta rsor► :use' ,T a 'G�b S�t1t a .� - ;; ted:: lra tttj�r�� _ "G bra eTak�n< Ditri Firsir _ flaw�Vl[ei hued �' C��site. oM pH 8.7 su 8.31 su 9 BOD 21.4 lbs/day 11 Ibs/day 9 TSS 91.4 Ibs/day 39.9 Ibs/day 9 FCOLI BR 20 #/100ml 5.6 #/100ml 9 1,1-DCE 0.00725 lbs/day 0.0043 Ibs/day 4 1,1-DCEY 0.00725 Ibs/day 0.0039 Ibs/day 4 Additional pollutants in attachment I Sampling shall be conducted according to sufficiently sensitive test procedures (i.e., methods) approved under 40 CFR 136 for the analysis of pollutants or pollutant parameters or required under 40 CFR chapter I, subchapter N or 0. See instructions and 40 CFR 122.21(e)(3). EPA Form 3510-2F (Revised 3-19) Page 9 Form 2F - Table B Supplemental Data Pollutant Pollutant Code 2019--F 2020 2021 2022 Units # of events sampled Max Discharge 111-TCE 34506 NS NS NS 0.00261 Ibs/day 1 112-TCE 34511 NS NS NS 0.0013 Ibs/day 1 124-TCB CO551 NS NS NS < 0.5 Ug/I 1 124-TCB QD551 NS NS NS 0.0013 Ibs/day 1 1,2-DCB 34536 <0.012 <0.0145 < 0.00241 0.00261 Ibs/day 4 1,2-DCE 32103 <0.012 <0.0145 < 0.00241 0.00261 Ibs/day 4 1,2-DCP 34541 <0.012 <0.0145 < 0.00241 0.00261 Ibs/day 4 t-12DCEY 34546 <0.012 <0.0145 < 0.00482 0.00522 Ibs/day 4 1,3-DCPE 77163 <0.012 <0.0145 < 0.00241 0.00261 Ibs/day 4 1,3-DCB 34566 <0.012 <0.0291 < 0.0241 0.00261 Ibs/day 4 1,4-DCB 34571 <0.012 <0.0291 < 0.0241 0.00261 lbs/day 4 2,4-DCPH 34601 <0.024 <0.0291 < 0.0241 0.0268 Ibs/day 4 2,4-DMPH 34606 <0.024 <0.0291 < 0.0482 0.0537 Ibs/day 4 2,4-DNPH 34616 <0.124 <0.148 < 0.0723 0.0806 Ibs/day 4 2,4-DNT 34611 <0.024 <0.0291 < 0.0241 0.0268 Ibs/day 4 26DINITR - QD626 <20 <20 < 20 0.0537 Ibs/day 4 2CPHENOL 34586 <0.024 <0.0291 < 0.0241 0.0268 Ibs/day 4 2NPHENOL 34591 <0.024 <0.0291 < 0.0241 0.0268 Ibs/day 4 34-BNZFA 79531 <10 <10 < 10 < 10.3 Ug/I 4 34-BNZFA QD531 NS NS NS 0.0268 Ibs/day 1 46DN-o-C 34657 <0.0124 <0.148 < 0.0723 0.0806 Ibs/day 4 4NPHENOL 34646 <0.024 <0.0291 < 0.0241 0.0268 Ibs/day 4 ACENAPEN 34205 <0.024 <0.0291 < 0.0241 0.0268 Ibs/day 4 ACENAPYL 34200 <0.049 <0.0582 < 0.0482 0.0537 Ibs/day 4 ACRYLONI 34215 <100 <100 < 5 0.013 lbs/day 4 ANTHRACE QD220 NS NS NS 0.0268 Ibs/day 1 BENZENE 34030 <0.012 <0.0145 < 0.001205 0.00013 Ibs/day 4 BNZO-A-A 34526 <10 <10 < 10 < 10.3 Ug/I 4 BNZO-A-A QD526 NS NS NS 0.0268 Ibs/day 1 BNZO-A-P 34247 NS NS < 10 < 10.3 Ug/I 2 BENZO(A)- QD247 NS NS NS 0.0268 ibs/day 1 BNZO-K-F 34242 <10 <10 < 10 < 10.3 Ug/I 4 BNZO-K-F QD242 NS NS NS 0.0268 lbs/day 1 B2E PHTH 39100 <0.024 <0.0291 < 0.0241 0.0268 Ibs/day 4 B2E PHTH CO100 NS NS NS < 10.3 Ug/I 1 CARBNTET 32102 <0.012 <0.0145 < 0.00241 0.00261 lbs/day 4 CHLROBNZ 34301 <0.012 <0.0145 < 0.00241 0.00261 Ibs/day 4 CLROETHA 85811 <0.024 <0.0291 < 0.00241 0.00261 Ibs/day 4 CHLRFORM 32106 <0.012 <0.0145 < 0.00241 0.00261 Ibs/day 4 Cr-TOTAL 1034 <10 <10 < 2 0.0104 Ibs/day 4 CHRYSENE 34320 <10 <10 < 10 0.0268 Ibs/day 4 COPPER 1042 <20 <20 13.8 25.4 Ug/I 4 COPPER- QD042 NS NS NS 0.014 Ibs/day 1 CN-CONC CO720 NS NS NS < 10 Ug/I 1 CN-QTY QD720 NS NS NS 0.0261 Ibs/day 1 CN-TOT 00720 <10 <10 < 10 NS Ibs/day 3 DIETY-PH 34336 <0.049 <0.0582 < 0.0482 0.0537 Ibs/day 4 DIMET-PH 34341 <0.024 <0.0291 0.0241 0.0268 Ibs/day 4 DNB PHTH 39110 <0.024 <0.0291 < 0.0241 0.0268 Ibs/day 4 ETHYLBEN 34371 <0.012 <0.0145 < 0.00241 0.00261 Ibs/day 4 FLUORANT QD376 NS NS NS 0.0268 Ibs/day 1 FLUORENE 34381 <0.024 <0.0291 < 0.0241 0.0268 Ibs/day 4 TOT HARD 900 NS AS NS '27 mg/l 1 CNA Holdings, LLC - Shelby NPDES Permit No. NCS000064 Page 1 of 2 September 2022 Form 2F - Table B Supplemental Data Pollutant Pollutant Code 2019--T 2020 2021 2022 Units # of events sampled Max Discharge HCB - Qty QD700 NS NS NS 0.0537 Ibs/day 1 HEXCLBD 39702 <0.049 <0.0582 < 0.0482 0.0537 Ibs/day 4 HEXCLBD CO702 NS NS NS < 20.6 ug/I 1 HCE 34396 <0.024 <0.0291 < 0.0241 0.0268 Ibs/day 4 LEAD 1051 <0.024 <0.0291 0.00361 0.00339 Ibs/day 4 METHYLCH 34418 <0.024 <0.0291 < 0.00241 0.00261 Ibs/day 4 MECL2 34423 <0.012 <0.0291 < 0.00482 0.00522 Ibs/day 4 NAPTHALE 34696 <0.024 <0.0291 < 0.0241 0.0268 Ibs/day 4 NICKEL 1067 <0.024 <0.0291 0.0151 0.013 Ibs/day 4 NITROBEN 34447 <0.024 <0.0291 < 0.0241 0.0268 Ibs/day 4 OIL-GRSE 556 <5 <5.5 < 5.7 < 5.5 mg/I 4 CER17DPF TGP3B PASS PASS PASS PASS pass/fail 4 PHENANTH 34461 <0.024 <0.0291 < 0.0241 0.0268 Ibs/day 4 PHENOL 34694 <0.024 <0.0291 < 0.0241 0.0268 Ibs/day 4 PYRENE 34469 <0.024 <0.0291 < 0.0241 0.0268 Ibs/day 4 SILVER 1077 NS NS NS < 1 ug/I 1 TETCLETY 34475 <0.012 <0.0145 < 0.00018 0.00196 Ibs/day 4 TOLUENE 34010 <0.012 <0.0145 < 0.00241 0.00261 Ibs/day 4 TCETHYLE 39180 NS NS NS 0.00261 Ibs/day 1 VINYLCHL 39175 NS NS NS 0.00261 Ibs/day 1 ZINC 1092 NS NS NS < 10 ug/I 1 HCB 39700 <20 <20 < 20 < 20.6 ug/I 4 FLUORANT 34376 <10 <10 < 10 < 10.3 ug/I 4 ANTHRACE 34220 <10 <10 < 10 < 10.3 ug/I 4 CNA Holdings, LLC - Shelby NPDES Permit No. NCS000064 Page 2 of 2 September 2022 SUPPLEMENTAL INFORMATION REQUIRED FOR RENEWAL OF INDIVIDUAL NPDES STORMWATER PERMIT Two copies of each of the following shall accompany this submittal in order for the application to be considered complete: (Do not submit the site Stormwater Pollution Prevention Plan) Initials (J 1. A current Site Map from the Stormwater Pollution Prevention Plan. The location of T� industrial activities (including storage of materials, disposal areas, process areas and loading and unloading areas), drainage structures, drainage areas for each outfall, building locations and impervious surfaces should be clearly noted. 2. A summary of Analytical Monitoring results during the term of the existing permit (if your permit required analytical sampling). Do not submit individual lab reports. The summary can consist of a table including such items as outfall number, parameters sampled, lab results, date sampled, and storm event data. (�L % 3. A summary of the Visual Monitoring results. Do not submit individual monitoring IT� reports. The summary can consist of a table including such items as outfall number, parameters surveyed, observations, and date monitoring conducted. U " 4. A summary of the Best Management Practices utilized at the permitted facility. U Summary should consist of a short narrative description of each BMP's in place at the facility. If the implementation of any BMP's is planned, please include information on these BMP's. 5. A short narrative describing any significant changes in industrial activities at the T� permitted facility. Significant changes could include the addition or deletion of work processes, changes in material handling practices, changes in material storage practices, and/or changes in the raw materials used by the facility. 6. Certification of the development and implementation of a Stormwater Pollution Prevention Plan for the permitted facility (Sign and return attached form). If the final year analytical monitoring of the existing permit term has not been completed prior to filing the renewal submittal, then the last years monitoring results should be submitted within 30 days of receipt of the laboratory reports. (i.e. do not withhold renewal submittal waiting on lab results) STORMWATER POLLUTION PREVENTION PLAN DEVELOPMENT AND IMPLEMENTATION CERTIFICATION North Carolina Division of Energy, Mineral, and Land Resources — Stormwater Program Facility Name: CNA Holdings LLC- Shelby Permit Number: NCSOOD064 Location Address: 2525 Blacksburg Road Grover. NC County: Cleveland "I certify, under penalty of law, that the Stormwater Pollution Prevention Plan (SPPP) document and all attachments were developed and implemented under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information required by the SPPP. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information gathered is, to the best of my knowledge and belief, true, accurate and complete." And "I certify that the SPPP has been developed, signed and retained at the named facility location, and the SPPP has been fully implemented at this facility location in accordance with the terms and conditions of the stormwater discharge permit." And "I am aware that there are significant penalties for falsifying information, including the possibility of fines and imprisonment for knowing violations." Sign (according to permit signatory requirements) and return this Certification. DO NOT SEND STORMWATER POLLUTION PREVENTION PLAN WITH THIS CERTIFICATION. Signature Lawrence Wanik or type name of person signing above Date 9-30-202 Z Site Director Title SPPP Certification 10/13 Attachment 2 (Copy 1) Supplemental Information ► Current Site Map ► Summary of analytical monitoring results ► Summary of visual monitoring results ► Summary of best management practices ► Significant changes in industrial activities 0 SOVTN DRAINAGE AREA wwx.osph :m. m vu.m ne w„ EAST DRAINAGE AREA ^ NORTH DRAINAGE AREA I� m' 8 i Analytical Monitoring Results Attachment 2 Summary of Analytical Monitoring Results NORTH OUTFALL Benchmark: 100 30 120 6-9 Period Date TSS (mg/L) BOD mg/L) COD (mg/L) pH 2H 2O18 11/ 12 2018 9.2 5.2 120 7.4 1H 2O19 5/11/2019 9.0 8.2 <50 7.7 2H 2O19 10/13/2019 57.6 11 <50 7.9 1H 2O20 3/10/2020 8.8 <2.0 <50 8.0 2H 2O20 11/11/2020 3.2 <2.0 <50 7.3 1H 2O21 3/16/2021 3.5 <2.0 <50 6.6 2H 2O21 8/3/2021 2.8 2.8 <50 7.4 1H 2O22 3/16/2022 21.1 13.4 53 6.7 Minimum 6.6 Maximum 57.6 13.4 120 8.0 Average 14.4 6.5 1 40.4 7.!:j Number of Storm Events Sampled 8 SOUTH OUTFALL Benchmark: 100 30 120 6-9 Period Date TSS (mg/L) BOD (mg/L) COD (mg/L) pH 2H 2O18 11/12/2018 7.9 <2.0 <50 6.7 1H 2O19 5/11/2019 14.7 5.3 <50 7.3 2H 2O19 10/13/2019 31.9 <2.0 <50 7.4 1H 2O20 3/10/2020 2.8 <2.0 <50 6.8 2H 2O20 11/11/2020 12.5 <2.0 <50 6.8 1H 2O21 3/16/2021 2.8 <2.0 <50 6.8 2H 2O21 8/3/2021 3.8 2.4 <50 6.6 1H 2O22 3/16/2022 3.9 <2.0 <50 6.9 Minimum 6.6 Maximum 31.9 5.3 <50 7.4 Average 10.0 3.9 125.0 6.9 Number of Storm Events Sampled 1 8 EAST OUTFALL Benchmark: 100 30 120 6-9 Period Date 5 (mg/L) BOD (mg/L) COD (mg/L) pH 2H 2O18 11/ 12/2018 6.5 <2.0 <50 7.3 1H 2O19 5/11/2019 16.0 5.7 <50 7.6 2H 2O19 10/13/2019 30.3 4.1 <50 7.5 IH 2O20 3/10/2020 14.4 <2.0 <50 8.2 2H 2O20 11/11/2020 13.4 <2.0 <50 7.4 1H 2O21 3/16/2021 7.3 <2.0 <50 7.6 2H 2O21 8/3/2021 2.5 2 <50 7.6 1H 2O22 3/16/2022 48.2 6.5 52 7.8 Minimum 7.3 Maximum 48.2 6.5 52 8.2 AverageAveragel 17.3 4.6 1 28.4 1 7.6 Number of Storm Events Sampled 8 CNA Holdings, LLC - Shelby NPDES Permit No. NCS000064 September 2022 Visual Monitoring. Results Attachment 2 Summary of Visual Monitoring Results NORTH Period Date Color Odor Clarity Floating Solids Suspended Solids Foam Oil Sheen Erosion/ deposition at outfall Other indicators 2H 2O18 11/12/2018 Lt Brown None 1 2 1 No No No No 1H 2O19 5/11/2019 Lt Brown None 1 1 1 No No No No 2H 2O19 10/13/2019 Lt Brown None 1 2 2 No No No No 1H 2O20 3/10/2020 Lt Red None 1 2 2 No No No No 2H 2O20 11/11/2020 Lt Red None 1 2 1 No No No No 1H 2O21 3/16/2021 Lt Brown none 2 2 1 No No No No 2H 2O21 8/3/2021 Lt Brown none 1 2 2 No No No No 1H 2O22 3/16/2022 Lt Brown None 1 2 1 No No No No SOUTH Period Date Color Odor Clarity Floating Solids Suspended Solids Foam Oil Sheen Erosion/ deposition at outfall Other indicators 2H 2O18 11/12/2018 Lt Red None 3 3 3 No No No No 1H 2O19 5/11/2019 Lt Brown None 2 1 1 No No No No 2H 2O19 10/13/2019 Lt Brown None 1 2 2 No No No No 1H 2O20 3/10/2020 Lt Brown None 1 3 1 No No No No 2H 2O20 11/11/2020 Lt Brown None 2 2 2 No No No No 1H 2O21 3/16/2021 None none 2 1 1 No No No No 2H 2O21 8/3/2021 Lt Brown none 2 2 2 No No No No 1H 2O22 3/16/2022 Lt Brown None 1 2 1 No No No No EAST Period Date Color Odor Clarity Floating Solids Suspended Solids Foam Oil Sheen Erosion/ deposition at outfall Other indicators 2H 2O18 11/12/2018 Lt Brown None 1 1 1 No No No No 1H 2O19 5/11/2019 Lt Brown None 1 1 1 No No No No 2H 2O19 10/13/2019 Lt Brown None 3 2 3 No No No No 1H 2O20 3/10/2020 Lt Brown None 2 2 2 No No No No 2H 2O20 11/11/2020 Lt Red None 2 2 2 No No No No 1H 2O21 3/16/2021 Lt Brown none 3 2 2 No No No No 2H 2O21 8/3/2021 Lt Brown none 1 1 2 No No No No 1H 2O22 3/16/2022 Lt Brown None 3 2 3 No No No No CNA Holdings, LLC - Shelby NPDES Permit No. NCS000064 September 2022 Best Management Practices Maintenance of Vehicles and Equipment DOS DONTS Use drip pans for oil collection. Perform maintenance near an open sewer drain. Properly dispose of all oils and lubricants. Maintain spare parts Promptly repair/replace defective equipment. Loading/Unloading of Chemical Materials Tank truck unloading/loading are restricted to areas having secondary containment capable of holding at least a single hose volume. The area beneath tank trucks is inspected for spills before and after unloading/loading. DOS DONTS Block off nearby open drainage ditches until all Allow transfer of bulk liquids unless a facility loading/unloading activities are completed. employee is present. Use gates and signage to restrict access during Operate pumps above acceptable limits unloading and loading. Locate hose connections over drip pads Construct temporary berms while conducting loading/unloading activities of large quantities of hazardous liquids Clean up spills in accordance with facility spill plan Liquid Storage in Aboveground Storage Tanks All storage units are fabricated from appropriate materials of construction for use conditions. All tanks are visually inspected daily for leaks as part of normal operation procedures. In addition, each tank is periodically inspected under the site Preventive Maintenance Program and Mechanical Integrity Program. DOS DONTS Regularly inspect secondary containment Leave secondary containment valves open berms and walls for cracks, breaks and gaps. unless releasing storm water that has been Records: Semi-annual inspection tested. Perform visual inspections of accumulated Leave used open/uncovered containers storm water prior to its release. Maintained by outside exposed to storm water. the Individual Business Units. EHSA Form: Secondary Containment inspection Form. Ensure that all employees receive storm water Release storm water not meeting training at least annually. requirements. Clean up any spills in accordance with facility Overfill tanks. spill plan. Waste Management and Storage DOs DONTs Keep all waste containers closed. Store incompatible wastes near each other. Label all containers as required by law. Store wastes in a non -designated area. Regularly inspect waste containers and storage areas for signs of leaks. Store waste in high traffic areas. Clean up any leaks or spills in accordance with the facility contingency plan. Outside Storage of Raw Materials, Flnlshed Products and By -Products DOs DONTs Regularly inspect drums for minor leaks and spills. Store materials in high traffic areas where they may be punctured or knocked over. Clean up spilled material promptly in accordance with facility spill plan. Store materials without proper lids. Maintain the minimum inventory necessary for operations. Discharge storm water from storage areas that does not meet requirements. Label all containers and tanks. Lawn Maintenance and Pesticide Application Contract personnel maintain Celanese Shelby lawns. This service projects a positive image of the facility and controls pests. Lawn maintenance includes herbicide and fertilizer application. In order to control pests, pesticides and insecticides may be applied around the facility, particularly in the office buildings. DOs DONTs Store maintenance equipment like lawn Over -apply chemicals. Use only the amount mowers under a roof. necessary to do the job. Dispose of unused Apply chemicals if a heavy rain is anticipated pesticides/herbicides/insecticides properly. in the next few days. Keep a minimum amount of these chemicals in stock at the facility. Apply pesticides, herbicides/insecticides in accordance with label instructions. Construction Construction activities may occur at the facility on an irregular basis. Because of the nature of construction, soil movement is a major component of most construction projects. Soil erosion and runoff are controlled during construction activities. DOs DONTs Put up a silt fence to limit sediment runoff from the construction area. Establish uncontrolled soil piles near facility drains. Use dust suppressant measures, like watering, if heavy construction is occurring. Leave contaminated soil uncovered at the site. Ensure mud/debris are minimized prior to entering public highways. Dispose of soil improperly. Re -seed or re -forest to minimize erosion. Put up retention walls on steep slopes. Equipment Painting Tanks. oioina. and other eauipment are painted at the facilitv on an irregular basis. DOs DONTs Store paints in properly labeled containers in Maintain a large inventory of paints at the ood condition. facilitv. Protect soil using tarps and remove stained If contractor, leave unused paints and supplies soil after painting. on plant site. Collect all sand blast material and dispose of Dispose in the general plant trash properly. Dispose of paint residue, rags, tarps and containers properly. Generally these materials fall under Resource Conservation and Recovery Act (RCRA). Clean painting equipment properly and dispose of old cleaning materials properly. Generally these materials fall under Resource Conservation and Recovery Act (RCRA). Clean up any spills promptly in accordance with facility spill plan and notify the Environmental Engineer(s) or ESHA Technician(s) . Recycling Areas DOs DONTs Dispose of scrap metals, which are clean of oil Use any faulty or damaged hoses or valves and grease in the scrap metal dumpster. during unloading, which could contaminate materials for recuclina. Cardboard stations with clean cardboard only. Significant Industrial Changes During the permit term, the facility shut down the Compounding operations within the facility. This change did not impact the stormwater activity at the facility. Attachment 2 (Copy 2) Supplemental Information ► Current Site Map ► Summary of analytical monitoring results ► Summary of visual monitoring results ► Summary of best management practices ► Significant changes in industrial activities :Site 1Map [L06L ON '+ J �tl Lny„aoW SZSZa3HS soJL m�av3n urtd�e xLvn nwis e u ( ' I I11 ASIIHS - - 353NV13J NHId 3ll5 A8lHS DNI '$ONIOIOH tlNJ 1 �g 9� w ¢{ St ff As £ p a w � ¢ A �C AfE Nil 95 Analytical Monitoring ,Results Attachment 2 Summary of Analytical Monitoring Results NORTH OUTFALL Benchmark: 100 30 120 6-9 Period Date TSS mg/L BOD (mg/L) COD mg/L) pH 2H 2O18 11/12/2018 9.2 5.2 120 7.4 1H 2O19 5/11/2019 9.0 8.2 <50 7.7 2H 2O19 10/13/2019 57.6 3.1 <50 7.9 1H 2O20 3/10/2020 8.8 <2.0 <50 8.0 2H 2O20 11/11/2020 3.2 <2.0 <50 7.3 1H 2O21 3/16/2021 3.5 <2.0 <50 6.6 2H 2O21 8/3/2021 2.8 2.8 <50 7.4 1H 2O22 3/16/2022 21.1 13.4 53 6.7 Minimum 6.6 Maximum 57.6 13.4 120 8.0 Average, 14.4 6.5 40.4 7.4 Number of Storm Events Sampled 1 8 SOUTH OUTFALL 7-7 Benchmark: 100 30 120 6-9 Period Date TSS (mg/L) BOD (mg/L) COD (mg/L) pH 2H 2O18 11/12/2018 7.9 <2.0 <50 6.7 1H 2O19 5/11/2019 14.7 5.3 <50 7.3 2H 2O19 10/13/2019 31.9 <2.0 <50 7.4 1H 2O20 3/10/2020 2.8 <2.0 <50 6.8 2H 2O20 11/11/2020 12.5 <2.0 <50 6.8 1H 2O21 3/16/2021 2.8 <2.0 <50 6.8 2H 2O21 8/3/2021 3.8 2.4 <50 6.6 1H 2O22 3/16/2022 3.9 <2.0 <50 6.9 Minimum 6.6 Maximum 31.9 5.3 <50 7.4 Average, 10.0 3.9 25.0 6.9 Number of Storm Events Sampled 1 8 EAST OUTFALL Benchmark: 100 30 120 6-9 Period Date TSS (mg/L) BOD (mg/L) COD (mg/L) pH 2H 2O18 11/12/2018 6.5 <2.0 <50 7.3 1H 2O19 5/11/2019 16.0 5.7 <50 7.6 2H 2O19 10/13/2019 30.3 4.1 <50 7.5 1H 2O20 3/10/2020 14.4 <2.0 <50 8.2 2H 2O20 11/11/2020 13.4 <2.0 <50 7.4 1H 2O21 3/16/2021 7.3 <2.0 <50 7.6 2H 2O21 8/3/2021 2.5 2 <50 7.6 1H 2O22 3/16/2022 48.2 6.5 52 7.8 Minimum 7.3 Maximum 48.2 6.5 52 8.2 Average 17.3 4.6 28.4 7.6 Number of Storm Events Sampled 8 CNA Holdings, LLC - Shelby NPDES Permit No. NCS000064 September 2022 Visual Monitoring Results Attachment 2 Summary of Visual Monitoring Results NORTH Period Date Color Odor Clarity Floating Solids Suspended Solids Foam Oil Sheen Erosion/ deposition at outfall Other indicators 2H 2O18 11/12/2018 Lt Brown None 1 2 1 No No No No 1H 2O19 5/11/2019 Lt Brown None 1 1 1 No No No No 2H 2O19 10/13/2019 Lt Brown None 1 2 2 No No No No 1H 2O20 3/10/2020 Lt Red None 1 2 2 No No No No 2H 2O20 11/11/2020 Lt Red None 1 2 1 No No No No 1H 2O21 3/16/2021 Lt Brown none 2 2 1 No No No No 2H 2O21 8/3/2021 Lt Brown none 1 2 2 No No No No 1H 2O22 3/16/2022 Lt Brown None 1 2 1 No No No No Snl1TH Period Date Color Odor Clarity Floating Solids Suspended Solids Foam Oil Sheen Erosion/ deposition at outfall Other indicators 2H 2O18 11/12/2018 Lt Red None 3 3 3 No No No No 1H 2O19 S/11/2019 Lt Brown None 2 1 1 No No No No 2H 2O19 10/13/2019 Lt Brown None 1 2 2 No No No No 1H 2O20 3/10/2020 Lt Brown None 1 3 1 No No No No 2H 2O20 11/11/2020 Lt Brown None 2 2 2 No No No No 1H 2O21 3/16/2021 None none 2 1 1 No No No No 2H 2O21 8/3/2021 Lt Brown none 2 2 2 No No No No 1H 2O22 3/16/2022 Lt Brown None 1 2 1 No No No No FAST Period Date Color Odor Clarity Floating Solids Suspended Solids Foam Oil Sheen Erosion/ deposition at outfall Other Indicators 2H 2O18 11/12/2018 Lt Brown None 1 1 1 No No No No 1H 2O19 5/11/2019 Lt Brown None 1 1 1 No No No No 2H 2O19 10/13/2019 Lt Brown None 3 2 3 No No No No 1H 2O20 3/10/2020 Lt Brown None 2 2 2 No No No No 2H 2O20 11/11/2020 Lt Red None 2 2 2 No No No No 1H 2O21 3/16/2021 Lt Brown none 3 2 2 No No No No 2H 2O21 8/3/2021 Lt Brown none 1 1 2 No No No No 1H 2O22 3/16/2022 Lt Brown None 3 2 3 No No No No CNA Holdings, LLC - Shelby NPDES Permit No. NCS000064 September 2022 Best :Management Practices Maintenance of Vehicles and Equipment DOs DONTs Use drip pans for oil collection. Perform maintenance near an open sewer drain. Properly dispose of all oils and lubricants. Maintain spare parts Promptly repair/replace defective equipment. Loading/Unloading of Chemical Materials Tank truck unloading/loading are restricted to areas having secondary containment capable of holding at least a single hose volume. The area beneath tank trucks is inspected for spills before and after unloading/loading. DOs DON'TS Block off nearby open drainage ditches until all Allow transfer of bulk liquids unless a facility loading/unloading activities are completed. emolovee is present. Use gates and signage to restrict access during Operate pumps above acceptable limits unloading and loading. Locate hose connections over drip pads Construct temporary berms while conducting _ loading/unloading activities of large quantities of hazardous liquids Clean up spills in accordance with facility spill planil Liquid Storage In Aboveground Storage Tanks All storage units are fabricated from appropriate materials of construction for use conditions. All tanks are visually inspected daily for leaks as part of normal operation procedures. In addition, each tank is periodically inspected under the site Preventive Maintenance Program and Mechanical Integrity Program. DOs DONTs Regularly inspect secondary containment Leave secondary containment valves open berms and walls for cracks, breaks and gaps. unless releasing storm water that has been Records: Semi-annual inspection tested. Perform visual inspections of accumulated Leave used open/uncovered containers storm water prior to its release. Maintained by outside exposed to storm water. the Individual Business Units. EHSA Form: Secondary Containment inspection Form. Ensure that all employees receive storm water Release storm water not meeting training at least annually. requirements. Clean up any spills in accordance with facility Overfill tanks. spill plan. Waste Management and Storage DOs DONTs Keep all waste containers closed. Store incompatible wastes near each other. Label all containers as required by law. Store wastes in a non -designated area. Regularly inspect waste containers and storage areas for signs of leaks. Store waste in high traffic areas. Clean up any leaks or spills in accordance with the facility contingency plan. Outside Storage of Raw Materials, flnlshed Products and By -Products DOS DON'TS Regularly inspect drums for minor leaks and spills. Store materials in high traffic areas where they may be punctured or knocked over. Clean up spilled material promptly in accordance with facility spill plan. Store materials without proper lids. Maintain the minimum inventory necessary for operations. Discharge storm water from storage areas that does not meet requirements. Label all containers and tanks. Lawn Maintenance and Pesticide Application Contract personnel maintain Celanese Shelby lawns. This service projects a positive image of the facility and controls pests. Lawn maintenance includes herbicide and fertilizer application. In order to control pests, pesticides and insecticides may be applied around the facility, particularly in the office buildings. DOS DONTS Store maintenance equipment like lawn Over -apply chemicals. Use only the amount mowers under a roof. necessary to do the job. Dispose of unused Apply chemicals if a heavy rain is anticipated pesticides/herbicides/insecticides properly. in the next few days. Keep a minimum amount of these chemicals in stock at the facility. Apply pesticides, herbicides/insecticides in accordance with label instructions. Construction Construction activities may occur at the facility on an irregular basis. Because of the nature of construction, soil movement is a major component of most construction projects. Soil erosion and runoff are controlled during construction activities. DOs DONTs Put up a silt fence to limit sediment runoff from the construction area. Establish uncontrolled soil piles near facility drains. Use dust suppressant measures, like watering, if heavy construction is occurring. Leave contaminated soil uncovered at the site. Ensure mud/debris are minimized prior to entering public highways. Dispose of soil improperly. Re -seed or re -forest to minimize erosion. Put up retention walls on steep slopes. Equipment Painting Tanks, pipinq, and other equipment are painted at the facility on an irregular basis. DOs DONTS Store paints in properly labeled containers in Maintain a large inventory of paints at the good condition. facilitv. Protect soil using tarps and remove stained If contractor, leave unused paints and supplies soil after paintinq. on plant site. Collect all sand blast material and dispose of Dispose in the general plant trash properly. Dispose of paint residue, rags, tarps and containers properly. Generally these materials fall under Resource Conservation and Recovery Act (RCRA). Clean painting equipment properly and dispose of old cleaning materials properly. Generally these materials fall under Resource Conservation and Recovery Act (RCRA). Clean up any spills promptly in accordance with facility spill plan and notify the Environmental Engineer(s) or ESHA Technician(s) . Recycling Areas DOs DONTs Dispose of scrap metals, which are clean of oil Use any faulty or damaged hoses or valves and grease in the scrap metal dumpster. during unloading, which could contaminate materials for recvclina. Cardboard stations with clean cardboard only. Significant Industrial Changes During the permit term, the facility shut down the Compounding operations within the facility. This change did not impact the stormwater activity at the facility.