Loading...
HomeMy WebLinkAboutSW6220905_Plansheet - SCM Detail_20220929r (�:11I� I N:54911-� 67 rill, E:202532b;61 N:549105.141 `��/ NOTE: i� \� STORMWATER PONDS ARE TO BE CONSTRUCTED FOR USE /� ( 2'-2" X 3' PRECAST CONCRETE N: 9137. \ / ASATEMPORARY SEDIMENT BASIN DURING CONSTRUCTION. / / - � J /� \ ram\ "RISER WITH TRASH RACK - Lr):202 6.0\ ONCE CONSTRUCTION IS COMPLETED THE TEMPORARY > _ I �^ <<\I ^ SEE DETAIL �� • \ \ SEDIMENT BASIN IS TO BE CLEANED UP AND SHAPED PRIOR TO BE USED ASASTORMWATER POND. r ( \� -\\-` 4 j� . L // \��\/ �_ \ / -- ���� \ �V 88°01'02" E N \� INV OUT = 159.00' ... 71' \ \ E:2025251.941 j, \ I I I 1 ,v I 01 / `4, r /� I� 78691 / \ INV OUT = 160.00' � 289 LF 15" RCP OUTLET � � � � � � �I J T /' \ BARREL @ 0.35%SLOPE -LLL -LLL -LLL -LLL -LLL -LLLrQ'.,ti���/� 0000 0000 _ o i i ANTI -SEEPAGE COLLAR SEE DETAIL �► �� ti \0 I �` / ter, ^ / ANTI -SEEPAGE COLLAR - SEE DETAIL J1L J1L J1L J1Li t '700OF / / / / _ > \� i/ `_ / / ✓ - - - - 7 1 - \ _ J1L J1L J1L Jam,/ 4 / / /� (/ C\�V/ �/ /�/ /♦//< ham/ q, J/ �♦♦♦♦k /-/ t/ �` R=383.16' / \\�~ CONSTRUCTION SEQUENCE FOR WET DETENTION POND: OD= 14'27'10" /\\ J / / _ _ - J C= 96.40' _ i 1. INSTALL EROSION CONTROLS j♦♦ / n�/ -�--- iJ DOC= 14'57'12" / \ 2. CONSTRUCT DAM BASE AND AREAS BELOW THE NORMAL POOL. CONSTRUCTION TO BE , PERFORMED UNDER THE INSPECTION OF THE GEOTECHNICAL ENGINEER. SEED UPON �\ COMPLETION �j r - � 3. INSTALL OUTLET PIPE, RIPRAP APRON AND STONE FILTER RING. 4. CONSTRUCT OUTLET STRUCTURE, INSTALL TEMPORARY SKIMMER. 5. UPON COMPLETION AND STABILIZATION OF UPSTREAM DEVELOPMENT, REMOVE f / / \ _ /\ SKIMMER, INSTALL PERMANENT ORIFICE DRAWDOWN DEVICE AND SEED UPON \'t / // COMPLETION. / N:5489 0.78/ �� , j,� �1 \ E:2 0258.611 , 1_-------------- 168 167 166165164163 0 0 0 0 0 0 0 0°0 Tr 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o 0 0 o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o 0 0 0 o 0 0 000000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00 0 0-0-0-0-0-0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 000°000°000 0 0 0 0 0 0 0 0 0°0 o° °00 oo°° 158 °oo °o°° 156 060 ° o / o ° °oo°° VEGETATIVE LITTORAL °°0000 SHELF r N o° °°o°o Al °0 DOoo `- °°O°O 0° O0 1 ° o oo °o CD °o I oo I °O a I o°o Lr) oo I / N:549024.87 E:2025672.07 i� L STORMWATER MANAGEMENT EASEMENT / ( STORMWATER 7 MANAGEMENTS EASEMENT ` /��\ \\ ��� /<���� A=3671' I �l ( .10 \ g y\/ _ R= 45.00' a / ) I/ OD= 46'44'46" I \� / N:5 8926.87 - \- j \y/ E:2/25229.17 /r/ \ (( /o. / / / DOC= 127'19'26" �� N:548901.38 E:2025573.19 VEGETATIVE SHELF PLANTINGS: AREA OF VEGETATIVE SHELF: 2,846 SF MIN. PLANTS REQUIRED: 712 PLANT TYPE: SCIENTIFIC NAME: EUPATORIADELPHUS MACULATUS EUPATORIUM PURPUREUM RHYNCHOSPORA COLORATA 170 168 166 164 162 160 158 156 154 152n 150 WET POND PLAN VIEW SCALE: 1" = 30' COMMON NAME: QUANTITY: NURSERY CONTAINER: SPACING: PLANTING SEASON: SPOTTED TRUMPETWEED 238 PEAT POT 6' O.C. SPRING/SUMMER JOE-PYE WEED 238 PEAT POT 6' O.C. SPRING/SUMMER STARRUSH WHITETOP 238 PEAT POT 6' O.C. SPRING/SUMMER TYPICAL VEGETATIVE SHELF DETAIL �Y.1G1��i►�K. EXISTING GROUND o z \ SCALE IN FEET 0' 10 20 40 BMP LANDSCAPE NOTES: 1. THE BMP LANDSCAPING SHALL BE IN COMPLIANCE WITH THE NCDEQ BMP REQUIREMENTS. 2. LANDSCAPE CONTRACTOR SHALL PROVIDE A TWO-YEAR WARRANTY PERIOD. ALL PLANTS THAT DO NOT SURVIVE MUST BE REPLACED. 3. AT THE END OF THE FIRST YEAR AND AT THE END OF THE TWO-YEAR WARRANTY PERIOD, ALL PLANTS THAT DO NOT SURVIVE MUST BE REPLACED. 4. ESTABLISHMENT PROCEDURES SUCH AS CONTROL OF INVASIVE WEEDS, ANIMAL AND VANDAL DAMAGE, MULCHING, AND WATERING SHALL BE IMPLEMENTED TO THE EXTEND NEEDED TO ENSURE PLANT SURVIVAL. 5. SOD WITHIN BMP AND SURROUNDING AREAS TO BE CENTIPEDE GRASS. 6. GRASS OR WILDFLOWER SEED MUST BE APPLIED AT THE RATES SPECIFIED BY THE SUPPLIERS. IF PLANT ESTABLISHMENT CANNOT BE ACHIEVED WITH SEEDING BY THE TIME OF SUBSTANTIAL COMPLETION OF THE STORM WATER FACILITY PORTION OF THE PROJECT, THEN THE CONTRACTOR SHALL PLANT THE AREA WITH WILDFLOWER SOD, PLUGS, CONTAINER PLANTS, OR OTHER MEANS TO COMPLETE THE SPECIFIED PLANTING AND PROJECT AGAINST EROSION BEFORE WATER IS ALLOWED TO ENTER THE STORM WATER BMP FACILITY. 7. ALL MATERIALS SHALL BE ACQUIRED FROM AN APPROVED NCDEQ PLANT VENDOR. PLANT MATERIAL SHOULD BE PURCHASED FROM A LOCAL SOURCE TO ENSURE SURVIVABILITY. 8. IMMEDIATELY AFTER THE WET DETENTION BASIN IS ESTABLISHED, THE PLANTS ON THE VEGETATED SHELF AND PERIMETER OF THE BASIN SHOULD BE WATERED TWICE WEEKLY IF NEEDED UNTIL THE PLANTS BECOME ESTABLISHED (COMMONLY SIX WEEKS). 9. NO PORTION OF THE WET DETENTION POND SHOULD BE FERTILIZED AFTER THE FIRST INITIAL FERTILIZATION THAT IS REQUIRED TO ESTABLISH THE PLANTS ON THE VEGETATED SHELF. 10. BMP PLANT SUBSTITUTIONS ARE NOT PERMITTED. 11. ONLY NON -CLUMPING TURF GRASSES SHALL BE USED. TREES AND WOODY SHRUBS SHALL NOT BE ALLOWED ON THE DAM OR TOP OF SLOPE AREA/10' MAINTENANCE AREA OF THE BMP. OF BASIN: 167.50 6" TOP SOIL ABOVE 6" CLAY LINER ON LITTORAL SHELF 50 YR EL: 16 .25' 25 YR EL: 16 .06' TEMPORARY POOL EL: 162.00 10 YR EL: 16 .86' l ._ _._._._._._._. _4_._._._._._._. ._ _._._ L: 161.00' ...... BOTTOM BOTTOM OF SHELF: OF SHELF: 1 162.00' 1.00' NORMAL POOL SEDIMENT CL ANOUT: 157.00' EL: 156.00' BO TOM OF POND i 6" CLAY SOIL LINER MAIN POOL DOUBLE GABION BASKET WEIR FOR THE FIRST 3 FEET. TOP OF GABION EL = 162.00' in o6 m c6 rn d in 0+00 0+50 1+00 1+50 2+00 2+50 3+00 WET POND PROFILE VIEW SCALE: 1 = 50 HORZ. 1 = 5 VERT. STORMWATER MANAGEMENT DESIGN WET DETENTION POND DESIGN STORM POST -RUNOFF STORM STAGE PRE -RUNOFF POND OUTFLOW 1-YEAR (24 HR) 0.74 CFS 161.54 FT-MSL 0.30 CFS 0.07 CFS 10-YEAR 30.10 CFS 162.86 FT-MSL 12.04 CFS 11.63 CFS 25-YEAR 33.49 CFS 163.06 FT-MSL 13.39 CFS 12.42 CFS 50-YEAR 35.82 CFS 163.25 FT-MSL 14.33 CFS 13.15 CFS 100-YEAR 38.04 CFS 163.45 FT-MSL 15.22 CFS 13.86 CFS DRAINAGE AREA TO POND: 14.61 AC. SITE IMPERVIOUS AREA TO POND: 3.71 AC 170 NOTE: ALL SEDIMENT DEPOSITED IN THE POND DURING CONSTRUCTION MUST BE REMOVED, EROSION FEATURES 168 MUST BE REPAIRED, AND THE VEGETATED SHELF MUST BE RESTORED, BEFORE OPERATION AS A STORMWATER BMP BEGINS. 166 164 NOTE: THE CONTRACTOR SHALL ENSURE THAT THE POND HAS A MAXIMUM INFILTRATION OF 0.01 IN/HR. THIS MAY BE 162 ACCOMPLISHED BY RE -DISTRIBUTING EXISTING CLAYS OR USING BORROW CLAY AS NECESSARY AS DIRECTED BY THE GEOTECHNICAL ENGINEER. 160 THE CONTRACTOR SHALL HAVE A NC LICENSED GEOTECHNICAL ENGINEER VERIFY A MAXIMUM OF 0.01 158 IN/HR INFILTRATION PRIOR TO CONVERTING THE EXCAVATED AREA FROM A SEDIMENT BASIN TO A PERMANENT WET DETENTION BASIN. IF 0.01 IN/HR 156 MAXIMUM INFILTRATION CANNOT BE MAINTAINED, A PERMANENT LINER WILL NEED TO BE INSTALLED . IF A LINER IS USE, THE SOIL MUST BE TESTED FOR INFILTRATION 154 RATE PRIOR TO INSTALLATION BY A NC LICENSED GEOTECHNICAL ENGINEER. 152 SCALE IN FEET MENNI 150 0' 25 50 100 .a'., S 86'54'21" E 126.20' v\ N:548882.77 E:2025542.72 20' DRAINAGE & ACCESS EASEMENT 000 / \�O° 01O r 1 J U) v / ll o°° I I I �' pip rl o o ( ^ Ul 0 L / 0^ < 0o L I 0° °° °°o ry oo ° ° 1 r 4 o° i N ly ° I/ 00 00 ooDOUBLE GABION o o°� BASKETWEIR I 0� Wo0 00o I IJ 0° 0 0 o° °o 0 Ul Ul 0 ICY) I ^ 1 r/ < i I J � I L I' I 0 �N 86o57'55" W J / 6" TOPSOIL ABOVE 6" CLAY LINER ON TRASH RACK BY PLASTIC LITTORAL SHELF SOLUTIONS INC. OR EQUIVALENT TOP OF RIM = 162.00' TRASH RACK 2'-2" X 3.0' SEE MANUFACTURERS PRECAST BOX SPECIFICATIONS FOR 4" PVC PIPE FOR DRAW DOWN ORIFICE DETAILS INV =161.00' SEE DETAIL 15" RCP INV OUT = WET POND - 160.00' V6� NOTE: 0o .................................... CONCRETE SHALL BE ELEV. - 158.00, PLACED IN RISER AFTER ANGLES ARE SECURE TO BASE AND RISER APPROXIMATE SIZE 3' X 4' CONC. BASE REINFORCED WITH EXCAVATE AND BACKFILL WITH #4 BARS AT 12" O.C. TOP AND BOTTOM OF COMPACTED FILL AS DIRECTED EACH DIRECTION. PROVIDE 3" MIN BY GEOTECHNICAL ENGINEER CLEARANCE BETWEEN EDGE OF CONCRETE AND STEEL REINFORCING. CUTOFF TRENCH - OUTFALL DETAIL SCALE: N.T.S. 12"< #4 REBAR @12" OC IN FRONT & REAR FACE OF COLLAR. REBAR TO HAVE 3" MIN. CONC. COVER FROM EDGE OF FACE OF COLLAR 6.5' 3.25' CONCRETE ANTI- SEEPAGE COLLAR SCALE: N.T.S. NOTES: 1) ALL CONCRETE TO BE 3000 PSI NON -FLY ASH 2) APPLY 1/2" THICK WRAP OF ASPHALTIC CEMENT AROUND DISCHARGE PIPE 6" BEYOND PLANNED SEEPAGE COLLAR ON BOTH SIDES 3) APPLY ADDITIONAL ASPHALTIC CEMENT AT PIPE/SEEPAGE COLLAR INTERFACE ON UPSTREAM FACES 4) TO BE FIELD INSPECTED BY GEOTECHNICAL ENGINEER. ASPHALTIC CEMENT TO MEET OR EXCEED FEDERAL SPECIFICATION SS-153 TYP1: ASTM-D-2822-75 TYPE 1. 4" PVC PIPE STUBBEDINTO OUTLET RISER 1. CONTRACTOR TO PROVIDE A PEAKED ROOF STRUCTURE TRASH RACK BY PLASTIC SOLUTIONS INC. (877-87775727) OR EQUIVALENT. 6" x 6" MAXIMUM GRATE OPENING 2. PROVIDE STEPS IN ALL DRAINAGE STRUCTURES DEEPER THAN 54". LOCATE STEPS WITHIN REASONABLE PROXIMITY TO ACCESS POINT (MANHOLE OR GRATE OPENING) WITHOUT INTERFERING WITH PIPE ORIENTATIONS. OUTLET RISER 4" PVC PLUG SCREW TYPE C7TEMPORARY POOL EL. 162.00' TEMPORARY 4" PVC POOL TEE NORMAL POOL EL. 161.00' PERMANENT POOL 2" DRAW DOWN ORIFICE DRAW DOWN ORIFICE DETAIL SCALE: N.T.S. INSPECTION AND MAINTENANCE PROVISIONS BMP ELEMENT POTENTIAL PROBLEM HOW TO REMEDIATE THE PROBLEM THE ENTIRE BMP TRASH/DEBRIS IS PRESENT. REMOVE THE TRASH/DEBRIS. THE PERIMETER OF AREAS OF BARE SOILAND/OR REGRADE THE SOIL IF NECESSARY TO THE WET DETENTION EROSIVE GULLIES HAVE FORMED. REMOVE THE GULLY, AND THEN PLANT BASIN GROUND COVER AND WATER UNTIL IT IS ESTABLISHED. PROVIDE LIME AND A ONE- TIME FERTILIZER APPLICATION. VEGETATION IS TOO SHORT OR MAINTAIN VEGETATION AT A HEIGHT OF TOO LONG. APPROXIMATELY SIX INCHES. THE INLET DEVICE: THE PIPE IS CLOGGED. UNCLOG THE PIPE. DISPOSE OF THE PIPE OR SWALE SEDIMENT OFF -SITE. THE PIPE IS CRACKED OR REPLACE THE PIPE. OTHERWISE DAMAGED. EROSION IS OCCURRING IN THE REGRADE THE SWALE IF NECESSARY TO SWALE. SMOOTH IT OVER AND PROVIDE EROSION CONTROL DEVICES SUCH AS REINFORCED TURF MATTING OR RIPRAP TO AVOID FUTURE PROBLEMS WITH EROSION. THE FOREBAY SEDIMENT HAS ACCUMULATED TO SEARCH FOR THE SOURCE OF THE A DEPTH GREATER THAN THE SEDIMENT AND REMEDY THE PROBLEM IF ORIGINAL DESIGN DEPTH FOR POSSIBLE. REMOVE THE SEDIMENT AND SEDIMENT STORAGE. DISPOSE OF IT IN A LOCATION WHERE IT WILL NOT CAUSE IMPACTS TO STREAMS OR THE BMP. EROSION HAS OCCURRED. PROVIDE ADDITIONAL EROSION PROTECTION SUCH AS REINFORCED TURF MATTING OR RIPRAP IF NEEDED TO PREVENT FUTURE EROSION PROBLEMS. WEEDS ARE PRESENT. REMOVE THE WEEDS, PREFERABLY BY HAND. IF PESTICIDE IS USED, WIPE IT ON THE PLANTS RATHER THAN SPRAYING. THE VEGETATED BEST PROFESSIONAL PRACTICES PRUNE ACCORDING TO BEST PROFESSIONAL SHELF SHOW THAT PRUNING IS NEEDED PRACTICES. TO MAINTAIN OPTIMAL PLANT HEALTH. PLANTS ARE DEAD, DISEADED OR DETERMINE THE SOURCE OF THE DYING. PROBLEM: SOILS, HYDROLOGY, DISEASE, ETC. REMEDY THE PROBLEM AND REPLACE PLANTS. PROVIDE ONE-TIME FERTILIZER APPLICATION TO ESTABLISH THE GROUND COVER IF A SOILTEST INDICATES IT IS NECESSARY. WEEDS ARE PRESENT. REMOVE THE WEEDS, PREFERABLY BY HAND. IF PESTICIDE IS USED, WIPE IT ON THE PLANTS RATHER THAN SPRAYING. THE MAIN TREATMENT SEDIMENT HAS ACCUMULATED TO SEARCH FOR THE SOURCE OF THE AREA A DEPTH GREATER THAT THE SEDIMENT AND REMEDY THE PROBLEM IF ORIGINAL DESIGN SEDIMENT POSSIBLE. REMOVE THE SEDIMENT AND STORAGE DEPTH. DISPOSE OF IT IN A LOCATION WHERE IT WILL NOT CAUSE IMPACTS TO STREAMS OR THE BMP. ALGAL GROWTH COVERS OVER CONSULT A PROFESSIONALTO REMOVE 50%OF THE AREA. AND CONTROL THE ALGAL GROWTH. CATTAILS, PHRAGMITES OR OTHER REMOVE THE PLANTS BY WIPING THEM INVASIVE PLANTS COVER 50%OF WITH PESTICIDE (DO NOT SPRAY). THE BASIN SURFACE. THE EMBANKMENT SHRUBS HAVE STARTED TO GROW REMOVE SHRUBS IMMEDIATELY. ON THE EMBANKMENT. EVIDENCE OF MUSKRAT OR USE TRAPSTO REMOVE MUSKRATSAND BEAVER ACTIVITY IS PRESENT. CONSULT A PROFESSIONALTO REMOVE BEAVERS. A TREE HAS STARTED TO GROW CONSULT A DAM SFETY SPECIALIST TO ON THE EMBANKMENT. REMOVE THE TREE. AN ANNUAL INSPECTION BY AN MAKE ALL NEEDED REPAIRS. APPROPRIATE PROFESSIONAL SHOWS THAT THE EMBANKMENT NEEDS REPAIR. THE OUTLET DEVICE CLOGGING HAS OCCURRED. CLEAN OUT THE OUTLET DEVICE. DISPOSE OF THE SEDIMENT OFF -SITE. THE OUTLET DEVICE IS DAMAGED. REPAIR OR REPLACE THE OUTLET DEVICE. THE RECEIVING WATER EROSION OR OTHER SIGNS OF CONTACT THE NC DIVISION OF WATER DAMAGE HAVE OCCURRED AT THE QUALITY WASHINGTON REGIONAL OFFICE, OR OUTLET. THE 401 OVERSIGHT UNIT, 919-733-1786. STORM WATER MANAGEMENT NOTES: 1. THE DEVELOPER OR HIS AGENT SHALL CONTACT THE DESIGN ENGINEER WHEN THE BEST MANAGEMENT PRACTICES ARE CONSTRUCTED AND ABOUT TO BECOME OPERATIONAL SO THAT A FINAL INSPECTION CAN BE PERFORMED TO DETERMINE COMPLIANCE WITH THE APPROVED PLAN. 2. ANNUAL MAINTENANCE INSPECTION AND REPORT REQUIRED. THE OWNER OF A PERMITTED STRUCTURAL STORM WATER BMP SHALL ANNUALLY SUBMIT A MAINTENANCE AND INSPECTION REPORT FOR EACH BMP TO THE STORM WATER ADMINISTRATOR. ANNUAL INSPECTIONS SHALL BEGIN WITHIN ONE YEAR OF THE RECORDATION OF ANY DEED(S) SHOWING STORM WATER BMPS. 3. UPON COMPLETION OF THE PROJECT, THE ENGINEER OF RECORD SHALL CERTIFY THAT THE COMPLETED PROJECT IS IN ACCORDANCE WITH THE APPROVED STORM WATER MANAGEMENT PLANS AND DESIGNS. 4. A FINAL INSPECTION OF THE SITE AND STORM WATER BMP SHALL BE SCHEDULED WITH AND COMPLETED BY THE PROJECT ENGINEER. 5. NCDEQ AND THEIR ASSIGNS HAVE RIGHT TO ACCESS THE STORM WATER CONTROLS FOR INSPECTIONS OR MAINTENANCE AS NECESSARY. 6. THE PROPERTY OWNER IS RESPONSIBLE FOR MAINTAINING THE STORM WATER CONTROLS ACCORDING TO THE APPROVED MAINTENANCE PLAN AND DIRECTION OF NCDEQ. BMP MAINTENANCE: Important operation and maintenance procedures: 1. Immediately after the wet pond is established, the plants on the vegetated shelf and perimeter of the basin will be watered twice weekly if needed, until the plants become established (commonly six weeks). 2. No portion of the wet pond will be fertilized after the first initial fertilization that is required to establish the plants on the vegetated shelf. 3. Stable ground cover will be maintained in the drainage area to reduce the sediment load to the wet pond. 4. If the pond must be drained for an emergency or to perform maintenance, the flushing of sediment through the emergency drain will be minimized as much as possible. 5. Once a year, a dam safety expert should inspect the embankment. 6. The measuring device used to determine the sediment elevation shall be such that it will give an accurate depth reading and not readily penetrate into accumulated sediments. After the wet pond is established, it should be inspected quarterly and within 24 hours after every storm event greater than 1.0 inches (or 1.5 inches if in a Coastal County).. Records of operation and maintenance will be kept in a known set location and shall be available upon request. Inspection activities shall be performed as follows. Any problems that are found shall be repaired immediately. FLOW NOTES: 1) PRIOR TO INSTALLATION, MANUFACTURER SPECIFICATIONS OF FILTER MEDIA SHALL BE REVIEWED TO ENSURE THAT DISCHARGE FROM FILTER MEDIA SHALL MEET OR EXCEED THE PROVISIONS OF THE CLEAN WATER ACT. 2) ENSURE THAT PUMP PRESSURE DOES NOT EXCEED FILTER MEDIA PRESSURE RATING. 3) FILTER MEDIA MAY BE, BUT NOT LIMITED TO, SAND MEDIA FILTRATION PRACTICES. 4) PUMP STRAINER SHALL NOT BE IN CONTACT WITH BOTTOM OF POND. PUMP TA WATER LEVEL I<.IINTA9011►11 INFILTRATION BASIN DEWATERING SCALE: N.T.S. � Know what's below NO. Cell before you dig. Dial 811 o. can ssasszasas 2 ' Q , 9/2/22 0 0 In 0 O N o z bb N l0 ZO O U oM0 M z I CO LU to -0 t-n w M a- .y{.y�..• ` �F} LU v Ol L M U Ln 01 N p-0M @jU LI_ •C: N -0 >- o // -� z �/� LL W z O a •M LU CL M W �!4 REVISION DESCRIPTION: 1 DATE: V / Q Q Z W 0 J C U z L `w 1 W O Q Z z w (W0 D Q ��••� v) J °C O Z L z Q Q V / L DESIGNED BY. JEH DRAWN BY. APPROVED BY. JEH SHEET. C8.0 CIVIL