HomeMy WebLinkAboutNCC223062_Site Plan or Location Map_20220901sz
L
C
n
O
�1
0
is SITE , R
,p
c
Lion Blvd
got
Me
4U1
SCORE Academy:
Gamer
VICINITY MAP
0 Property
Project Data Sheet
Planning and Development Customer Service Center • One Exchange Plaza, Suite 400 1 Raleigh, NC 27601 1 919-996-2500
no
0 250 500 1000 ft
1 inch equals 500 feet
D►sclalmer
Maps makes every effort to produce and publish
the most current and accurate information possible.
However, the maps are produced for information purposes,
and are NOT surveys. No warranties, expressed or implied
,are provided far the data therein, its use,or its interpretation.
Raleigh
This form must be completed and applied to the cover sheet of drawings submitted with a Non -Residential building
permit associated with a Site Permit Review, or permits for an apartment, office, and/or commercial uses.
GENERAL INFORMATION
Development Name: Frontier Plaza I
Proposed Use: Office, warehouse and retail
Property Address(es): 3808 S. Wilmington Street
Approved Site Plan or Subdivision case #: ASR-0093-2021
Wake County Property Identification Number(s) (PIN) for each parcel to which these guidelines will apply:
PIN #: 1701391659
PIN 4: 1701391659
PIN #: 1701391659
PIN #: 1701391659
❑
Apartment
❑
Bank
❑
Congregate care
❑
Hospital
❑
Hotel/Motel
❑
Industrial building
❑
Mixed residential
❑
Non-residential condo
What is the
✓❑
Office
❑
Religious institution
❑
Residential condo
❑✓
Retail
project type?
❑
School
❑
Shopping center
❑
Single-family
residential
❑
Telecommunication
tower
❑
Townhouse
❑
Civic use: Park, community center, museum or
government facility
❑V
Other
Scope of work:
79,588 SF building for warehouse distribution
(with warehouse, office and retail).
FOR APARTMENTS, CONDOS, AND TOWNHOMES ONLY
1. Total number of townhouse lots: Number attached: Number detached:
2. Total number of apartment or condominium units:
3. Total number of Congregate Care or Life Care Dwelling units:
4. Overall total number of dwelling units (from 1-3 above):
5. Number of bedroom units: 1 BR: 2BR:
3BR: 41319 or more:
6. Overall unit(s) per acre densities per zoning district(s):
DEVELOPMENT TYPE AND SITE DATA
TABLE (applicable to all developments)
Zoning Information
Building Information
Zoning district(s):IX-3
Proposed use of building(s): Warehouse, office and retail
If more than one district, provide acreage of each:
Proposed sq. ft. of building(s) gross: 79,588 SF
Overlay district(s):SWPOD Overlay
Existing sq. ft. of building(s) gross:0
Total site acreage:6.7 (after Ri'W dedication)
Total sq. ft. gross (existing and proposed): 79,588 SF
Off street parking: Required: 73 Provided: 76
Proposed height of building(s):29'-9"
COA (Certificate of Appropriateness) case #:
FAR (floor area ratio) %:27.3%
BOA (Board of Adjustment) case # A -
Building lot coverage %:27.3%
CUD (Conditional Use District) case # Z -
Inside City Limits? Yes ✓❑ No ❑
PAGE 1 or 2
SITE COMPLIANCE NOTES
— THIS SITE IS EXEMPT FROM BLOCK PERIMETER REQUIREMENTS PER UDO
8.3.2.2.b.
—THIS SITE SHALL BE FULLY COMPLIANT WITH SWIFT CREEK PROTECTION
OVERLAY DISTRICT (SWPOD) PER UDO SECTIONS 5.2.5 AND 9.5.3
—THIS SITE IS EXEMPT FROM THE REQUIREMENTS OF UDO SECTION 9.1.9
AS THE PROPERTY IS LOCATED IN AN AREA DESIGNATED FOR IMPERVIOUS
SURFACES IN EXCESS OF 30% PER 9.1.9.E AND CITY OF RALEIGH
COMPREHENSIVE PLAN POLICY AP—SC8 AND MAP AP—SC1.
CONDITIONS OF APPROVAL
—RECORDED PLAT WITH RIGHT OF WAY DEDICATION
—RECORDED PLAT WITH EASEMENTS FOR SCM PRIVATE DRAINAGE EASEMENT,
SLOPE EASEMENT, CITY OF RALEIGH PUBLIC WATERLINE EASEMENT AND
UTILITY PLACEMENT EASEMENT.
—FEE IN —LIEU SHALL BE PAID FOR EIGHT (8) STREET TREES ALONG THE CITY
OF RALEIGH THOROUGHFARE AT THE REAR OF THE PROPERTY
—FEE IN —LIEU SHALL BE PAID FOR ONE HALF OF AVENUE 4 LANE DIVIDED
SECTION AT THE REAR OF THE PROPERTY, INCLUDING WATERLINE.
—DEMOLITION PERMIT SHALL BE REQUIRED FOR THE SHED ON THE PROPERTY.
SOLID WASTE SERVICES STATEMENT
— DEVELOPER/OWNER HAS REVIEWED THE CITY OF RALEIGH SOLID WASTE
DESIGN MANUAL AND SHALL COMPLY WITH IT'S REQUIREMENTS.
— ONSITE SCREENED DUMPSTER AREA TO BE PROVIDED BY PRIVATE
SOLID WASTER SERVICES PICK UP.
Traffic Control and Pedestrian Plan (TCPEDI Notes:
* Prior to any work that impacts the right-of-way, closing or detouring of any street, lane,
or sidewalk, the contractor must apply for a permit with Right -of -/Nay Services. Please
direct any questions to rightofwayservicesraleighnc.gov.
.6 The street, lane, sidewalk, closure permit is required for any closure on city streets and
all NCDOT streets within RaIeigh's Jurisdiction,
.0 A permit request with a TOPED Plan shall be submitted to Right -of -Way Services through
the City of Raleigh Permit and Development Portal.
-0 Prior to the start of work, the Client shall schedule a Pre -Construction meeting with the
Engineering Inspections Coordinator to review the specific components of the approved
plan, and ensure all permits are issued.
-0 All TOPED Plans shall comply with all Local, State, and Federal requirements and
standards, including but not limited to:
o Manual on Uniform Traffic Control (MUTCD);
o Public Rights -of -Way Accessibility Gu [del Ines (PROWAG);
o American Disability Act (ADA) requirements;
v Raleigh Street Design Manual (RSDM).
+ All public sidewalks must be accessible to pedestrians who are visually impaired andjor
people with mobility concerns. Existing and alternative pedestrian routes during
construction shal I be required to be compliant with the Public Rights of Way
Accessibility Guidelines (PROWAG), the ADA Standards for Accessible Design and the
Manual on Uniform Traffic Control Devices (MUTCD).
+ All permits must be available and visible on site during the operation.
STORMWATER INFORMATION
Existing impervious surface:.54 Acres
acres/square feet
Proposed impervious surface: 3.86 Acres acres/square feet
Neuse River buffer: Yes
❑
No ❑✓ Wetlands: Yes ❑ No ✓❑
Flood Hazard Area: Yes
No ✓
If yes, Alluvial soils:
Flood Study:
FEMA Map Panel #:
Total disturbed area: 6.2 acres acreslsquare feet
REVISION 11.16.20
raleighnc.gov PAGE 2 or 2
REVISION 11.16.20
raleighnc.gov
FRONTIER PLAZA
SITE PERMIT DRAWINGS
IX-3 ZONING
SPR=0095=2022
r� I
I
t
(!� N
N
I =
'
�o
cc
L
3�w
M z W oa
r
F U
I
40
i
0 100 200 300
I
ATTENTION CONTRACTORS
The Construction Contractor responsible for the extension of water,
sewer, and/or reuse, as approved in these plans, is responsible for
contacting the Public Works Department at (919) 996-4540, at
least twenty—four hours prior to beginning any of their
construction.
Failure to notify both City Departments in advance of beginning
construction, will result in the issuance of monetary fines, and
require reinstallation of any water or sewer facilities not inspected
as a result of this notification failure.
Failure to call for Inspection, Install a Downstream Plug, have
Permitted Plans on the Jobsite or any other Violation of City of
Raleigh Standards will result in a Fine and Possible Exclusion from
future work in the City of Raleigh.
Z 9
PATRIOT
Sanitation Management
December 30, 2021
Upon review of the site plan and dumpsterl recycle bin location for plans sent to us for
the building at 3808 South Wilmington Raleigh, NC 27603, we believe that Patriot could
service this location as currently designed, continuing our service provided to Frontier
Auto Body Supply at their new building location.
Should you have any additional gluestions feel free to reach me at 919-422-7070 or
rwilliams@patriotsanitation.com.
Sincerely,
Ronald Williams
OVERVIEW
SCALE: 1 " = 100'
PUBLIC IMPROVEMENTS
PHASE NUMBER(S) PHASE 1
NUMBER OF LOT(S) 1
LOT NUMBER(S) BY PHASE N/A
NUMBER OF UNITS 1
LIVABLE
BUILDINGS
U
OPEN SPACE?
NO
NUMBER
OF OPEN SPACE
LOTS
0
PUBLIC
WATER (LF)
0
PUBLIC
SEWER (LF)
0
PUBLIC
STREET (LF) —
FULL
0
PUBLIC
STREET (LF) —
PARTIAL
0
PUBLIC
SIDEWALK (LF)
— FULL
0
PUBLIC
SIDEWALK (LF)
— PARTIAL
265
STREET SIGNS (LF) U
WATER SERVICE STUBS 4
SEWER SERVICE STUBS 1
Know what's below.
Call before you dig.
ENGINEER
CAPITAL CIVIL ENGINEERING, PLLC
1011 PEMBERTON HILL RD, STE 203
APEX, NC 27502
PH: 919 249-8587
MICHAEL McQuillen, PE
mmcqu it len®capitalcivil.com
DEVELOPER
WAYNE ENTERPRISES, LLC
2509 RUNNER STONE WAY
RALEIGH, NC 27603
U
z
CD
a w J
N <
a
J Ld
1.L W
I.L ~
W z
O
z
0 z
I.L _J
LL §
Ad
00
O
CO
M
SHEETINDEX
COVER
C100
U) U)
z z
AA LETTER
C101
w w
O O
EXISTING CONDITIONS & DEMO
C102
0 0
O O
SITE PLAN
C200
U U
W W
OFFSITE ROAD IMPROVEMENT PLAN
C201
CL CL
GRADING PLAN
C300
I I
z
N a
0 N N
ROAD WIDENING GRADING AND CROSS SECTIONS
C301
Ui o c�
UJ
SIGHT DISTANCE PROFILE
C302
0:� to r
0
SCM DETAILS C303—C306
UTILITY PLAN
C400
0 Co0
LIGHTING PLAN
C401
a r U
U co J
Z o
TREE CONSERVATION AREA PLAN
C500
W
I
W
w o
LANDSCAPING PLAN
C501
Q��
t
LANDSCAPE DETAILS
C502
�
_
(3
rn w
o Cn z_
SITE DETAILS
C600
W
N x
�`
U Z
SITE DETAILS
C601
o >
INITIAL EROSION CONTROL PLAN
C700
<
J � a
FINAL EROSION CONTROL PLAN
C701
CJ
= tr rL
a
ZO N U
EROSION CONTROL NOTES AND DETAILS
C702 — C704
J
(�f 01 (V
a)
CONSTRUCTION DETAILS
C800 — C806
m CV
W Z:
RETAINING WALL PLANS
RW 1.0 — 5.0
CL
l—
o
ARCHITECTURAL ELEVATIONS
SA1
U
o a
ov
ARCHITECTURAL FLOORPLAN
SA2
repaaerea oThrep'reun�t rote/ rempmpre wnnwall�egal reg oememe ror
aexlapmenz and rensvumion. The property ewper, .sago wnwna ana
ponzide ror romglenre wIM all appllrehle CM, Sa[e
ana reaewreal lawn Thlsspeaficauzhmlzmlon below pet a permlA pere n be
epewee m perms apv Ne1-ft.11 an, mre or eaeal row. All cepa.awp
mem ee m aearaaprewah all root, srae,ana 1 gelea ape gegelappna.
nn approval: TMe approval ie hang I•..w eleczronlnlly. Thls approval Is
re aery er galeigh genew onirer below. The ary
will retain apwpy of the pprovea pW .., work..h.— b ON approval
im
approval opreiss wmlinvalianetM1isapprov i. .,m�ifio Dory ghrs
gnv org hoew+epmemapproeal Paige? m
aryaf gaeigh review —
Digitally signed by Paige Townsend
Reason: I am approving this document.
Contact Info: Paige Townsend
Date: 2022.07.20 15:32:40-04'00'
SEAL R\ �C AH1111
SS/
.Q L
9 9 ' zz
zip F� P • M c
)12 /2022
DATE
JU LY 12, 2022
ISSUED FOR
CONSTRUCTION DRAWINGS
SHEET NO.
C100
WA WA
SA SA
TP TP TP
EXSSMH1
RIM:347.67
INV IN:325.52U
INV OUT:325.32
(EXSSMH2)
\ 20
UND DRAIN PIPES' AND
20' PERMANENT CLI�A WTS. REFER TO
SANITARY SEWER i
DETAIL-SHEET
EASEMENT
(DB 10865 PG 2180)
(BM 2004 PG 865)
EXISTING CONTOUR LINE - 1' INTERVAL
EXISTING CONTOUR LINE - 5' INTERVAL
PROPOSED CONTOUR LINE - 1' INTERVAL
PROPOSED CONTOUR LINE - 5' INTERVAL
PROPOSED STORM PIPE
RETAINING WALL WITH FENCE
PROPOSED WATER LINE
PROPOSED SANITARY SERVICE
ADA ROUTE
TREE PROTECTION FENCE
LIMITS OF DISTURBANCE
J, / I
EXSSMH-2 'PRIVATE DRAINAGE
RIM:329.68 NV IN:323.28 EASEMENT' FOR SCM
\�I
(EXSSMH1)
NV OUT:321.090
_VS C/) V A\
N
\ � M
\ cV I
327�
--_-=____-_-r _ - -
-- - -=335-
STRUC #
INLET TYPE
STA
INV UP
INV DOWN
TC
LENGTH
(FEET)
PIPE DIA
(INCHES)
SLOPE
Pipe
Material
15
CURB INLET
11+65
348.7
348.7
350.6
110
15
0.50%
RCP
14
CURB INLET
10+55
348.1
348.0
350.6
124
15
0.50%
RCP or HDPE
13
CURB INLET
9+31
347.7
347.5
353.6
52
18
0.50%
RCP or HDPE
12
CURB INLET
8+79
347.0
346.8
355.0
97
24
0.50%
RCP or HDPE
11
DROP INLET
7+82
346.6
346.5
353.0
47
24
0.50%
RCP or HDPE
10
DROP INLET
7+35
346.3
346.2
353.0
40
24
0.50%
RCP or HDPE
9
JUNCTION BOX
6+95
345.6
344.5
353.9
64
24
1.00%
RCP or HDPE
8
CURB INLET
6+31
343.8
343.7
352.8
201
1 24
1.00%
RCP or HDPE
7
CURB INLET
4+30
341.7
341.6
349.5
123
24
1.20%
RCP or HDPE
6
CURB INLET
3+07
340.1
340.0
349.5
108
24
1.20%
RCP or HDPE
5
CURB INLET
1+99
338.7
338.6
349.5
65
24
1.20%
RCP or HDPE
4
CURB INLET
1+34
337.8
337.6
349.5
61
30
1.00%
RCP or HDPE
3
CURB INLET
0+73
337.0
336.9
350.0
51
30
1.00%
RCP or HDPE
2
CURB INLET
0+22
336.4
336.2
349.6
22
1 30
1.00%
RCP or HDPE
1
ENDWALL
0+00
336.0
---
---
---
30
1.00%
RCP
18
CURB INLET
1+32
343.6
343.5
347.5
77
15
3.00%
RCP or HDPE
17
CURB INLET
0+55
341.2
339.2
347.9
55
15
5.00%
RCP or HDPE
2
CURB INLET
0+00
336.4
336.2
349.6
22
30
1.00%
RCP or HDPE
19
CURB INLET
0+59
343.1
342.9
347.5
59
15
3.00%
RCP or HDPE
17
CURB INLET
0+00
341.2
339.2
347.9
55
15
5.00%
RCP or HDPE
24
DROP INLET
3+28
344.5
344.4
346.6
141
15
0.80%
RCP or HDPE
23
DROP INLET
1+87
343.3
343.2
346.9
75
15
0.80%
RCP or HDPE
22
JUNCTION BOX
1+12
342.6
342.5
344.9
105
15
0.80%
RCP or HDPE
21
JUNCTION BOX
0+07
341.7
341.6
344.0
7
15
0.80%
RCP or HDPE
20
FES
0+00
341.5
---
---
---
15
0.80%
RCP or HDPE
6" HDPE ROOF DRAIN -
-140 LF
8" HDPE ROOF DRAIN -
-140 LF
10" HDPE ROOF DRAIN
- -238 LF
12" HDPE ROOF DRAIN
- -161 LF
15" HDPE ROOF DRAIN
- -192 LF
ROOF DRAIN CONENCTION POINTS - 35
ROOF DRAIN JUNCTION BOXES - 6
85LF 6" HDPE ROOF
DRAIN LEADER TO INLET 18
ALTERNATIVE TO DISCHARGE ON GROUND
Gv GGnIrG
TO EXISTING DRAW DIRECTEDv�
TO TO RIGHT OF WAY
HDPE NOTES:
1. HDPE SHALL CONFORM TO AASHTO M294 -
CORRUGATED EXTERIOR / SMOOTH INTERIOR
PIPE (TYPE S).
2. SHALL HAVE CERTIFICATION BY PPI (PLASTIC
PIPE INSTITUTE)
3. BELL AND SPIGOT JOINTS WITH 0-RING GASKET
REQUIRED. BELLS SHALL COVER TWO FULL
CORRUGATIONS ON EACH SIDE OF PIPE. GASKET
TO CONFORM TO ASTM F477.
4. INSTALLATION TRENCH WIDTH SHALL BE A
MINIMUM OF THE OUTSIDE DIAMETER OF THE
PIPE PLUS 4-FEET.
5. HDPE SHALL BE BACKFILLED WITH 4" OF #57
STONE BEDDING UNDER THE PIPE AND TO THE
SPRINGLINE OF PIPE. REMAINING BACKFILL
SHALL BE INSTALLED IN ACCORDANCE TO
CURRENT CITY STANDARDS.
6. COVER SHALL BE A MINIMUM OF 18-INCHES
FROM THE OUTSIDE WALL OF PIPE TO FINISHED
GRADE.
7. NO HDPE END TREATMENTS ALLOWED. ALL END
TREATMENTS SHALL BE REINFORCED CONCRETE.
SITE NOTES:
1. THE SITE IS LOCATED IN THE NEUSE RIVER BASIN AND THE
SWIFT CREEK WATERSHED
2. THE PLACEMENT OF ANY FILL MATERIAL MUST BE CONDUCTED
UNDER THE OBSERVATION OF A QUALIFIED LICENSED
GEOTECHNICAL TESTING FIRM
3. ANY RETAINING WALLS (INCLUDING GEOGRID) SHALL NOT BE
LOCATED WITHIN A RIGHT-OF-WAY, BUFFER, OR EASEMENT.
SEVERAL RETAINING WALLS ON THIS PROJECT ARE WITHIN 6'
OF AN EASEMENT AND WILL REQUIRE GEOGRID DESIGN THAT
DO NOT ENCROACH INTO THE EASEMENT. RETAINING WALL
COMPANY TO PROVIDE DESIGN DRAWINGS TO BE PERMITTED
SEPERATELY FROM THE CITY OF DURHAM. PROVIDE 4' FENCE
ALONG ALL WALLS THAT ARE GREATER THAN 2.5' HIGH.
ADA ACCESS NOTES:
ALL ADA ACCESSIBLE LOCATIONS ARE SHOWN ON THE PLAN. THEY
INCLUDE, BUT ARE NOT LIMITED TO; ADA PARKING SPACES, SIDEWALK
BETWEEN ADA PARKING SPACES AND MAIN BUILDING ENTRANCE,
SIDEWALK BETWEEN MAIN BUILDING ENTRANCE AND PUBLIC RIGHT OF
WAY.
ADA PARKING SPACE MAXIMUM SLOPE IN ANY DIRECTION IS 2%.
THIS INCLUDES ALL ADA PARKING SPACES AND ACCESS AISLES.
ADA ROUTES MAXIMUM RUNNING SLOPE IS 5% AND MAXIMUM CROSS
SLOPE IS 2%.
CONTRACTOR SHALL PREPARE FORMS FOR ADA PATHS PRIOR TO
POURING CONCRETE OR ASPHALT, CONTRACTOR SHALL VERIFY
RUNNING SLOPE AND CROSS SLOPE OF ADA PATHS A SMART LEVEL
DEVICE SHALL BE USED TO VERIFY THESE SLOPES.
UPON COMPLETION OF OF ALL ADA PATHS, CONTRACTOR SHALL
ONCE AGAIN VERIFY THE RUNNING AND CROSS SLOPE OF THESE
AREAS WITH A SMART LEVEL. ANY REPAIRS MADE SHALL BE THE
SOLE RESPONSIBILITY OF THE CONTRACTOR.
0 40 80 120
SCALE: 1 " = 40'
STORMWATER QUANITY AND QUALITY NOTES:
SITE AREA: 6.7 ACRES
IMPERVIOUS AREA: 3.8 ACRES
POST DEVELOPMENT STORMWATER QUANTITY SHALL BE MANAGED BY
A BIORETENTION AREA THAT WILL DETAIN THE RUNOFF RATES FOR
THE 1-YEAR, 2-YEAR AND 10-YEAR STORM EVENTS TO
PRE -DEVELOPMENT RUNOFF RATES.
POST DEVELOPMENT STORMWATER QUALITY SHALL BE ACHIEVED BY
THE USE OF AN UNDERGROUND INFILTRATION SYSTEM AND A
BIORETENTION AREA.
BUILDING AVERAGE GRADE TABLE (UDO SECTION 1.5.7):
THE BUILDING AVERAGE GRADE IS THE AVERAGE POST
DEVELOPMENT GRADE ABOVE SEA LEVEL ALONG THE BUILDING
ELEVATION MOST PARALLEL AND CLOSEST TO S. WILMINGTON
STREET, WHICH IS THE PRIMARY STREET.
HIGHEST
GRADE
ELEVATION
354.35'
LOWEST
GRADE
ELEVATION
354.35'
AVERAGE
GRADE
ELEVATION
354.35'
3'X20'X 1' THICK
CLASS B RIP -RAP
d50=6" IN EXISTING SWALE
TRITON UNDERGROUND STORMWATER
INFILTRATION SYSTEM WITH MAIN HEADER
ROW, SEDIMENT FLOOR AND SEDIMENT
SUMP
rewaerea oThrep'rezen�s rotal rempmnre wnnwall�eeal reo oemema ror
aexlapment and renssrumion. The property owner, a r wnwnams, ana
ponzide ror romglenre wIM all applireble CM. Stae
ana peaewresl lawn This speafipau[M11.l on below is not a permit - fiallnbe
orevuea to permit anY Nolmbn pi ah,State or eeaerel iew. All C -1.
mint�n Apprw lThlae plis alp.mwsage I...„A eenmumrallre-apbwoval la
re awry a naleighneriew onirer M1elaw. me ary
will retain a m of tM1e pprevea pans. Any work autM1orVaa by tns approval
kept on fik xim the ary. iris
my mpa hperalopmemAppm.al Paige? m
ary of -gh keview-
Digitally signed by Paige Townsend
Reason: I am approving this document.
Contact Info: Paige Townsend
Date: 2022.07.20 15:33:01-04'00'
F_
Z
O
W
LL
I- I-
IZ w
O o
0 0
U U
W W
CL CL
CN
N
O N_
W \ \
fY to r,
U
NO
X
6
Z
z
O
N
13
W
z
0
z
U
0
J
Z
a
J
'a.
V
Z
0
O
N
0
r a
N r U
U J
z _ �
X
W O
z
a `nOf
w 0� LaJ
W
o rn z
N X CD
W W Z
W
0 J
0 U
J
J_ aQ I-
_ a
ZO NQ
U
I-
CY O N
W O
m N
of
fl d S
o a
O
U
SEAL �C A R
SST
'Q L
9 9 ' zz
�12 /2022
DATE
JU LY 12, 2022
ISSUED FOR
;ONSTRUCTION DRAWIN
SHEET NO.
C300