Loading...
HomeMy WebLinkAboutSW5220201_Plansheet - Cover Sheet_20220517VICINITY MAP NOT TO SCALE S ITE s�. SCALE: 1 "=2,000' 0 2,000 4,000 US 64 SITE INFORMATION N.C. 581, SITE LOCATION: ...... SPRING HOPE, N.C. TRACK ACREAGE:._ ......71.83 Ac. NUMBER OF LOTS: ................... ......185 LINEAR FOOTAGE OF STREETS: .....10,358 LF OPEN SPACEREQUIRED:.. ......1 /35 Ac./LOT 1 /35 X 185 = 5.28 Ac. OPEN SPACE/STORMWATER AREA: ...... ...... 6.53 Ac. DISTURBED AREA:. ......±65.0 Ac. ZONE: ...................... ...... R -8 TAX ID# ....... ......2860 0025 8180 2860 1443 1572 DEED BOOK: ...... ......3154 DEED PAGE:.._____ ...174 MINIMUM BUILDING SETBACKS: FRONT: ............................................ ....25' SIDE--------------------.. ....10' REAR: .................. .... 25' CORNER SIDE:.____ 12.5' MINIMUM LOT WIDTH:. ......80 FT. MINIMUM LOT SIZE:..... ......8,000 SF TOWNSHIP:.__ ...... SPRING HOPE COUNTY:........ ...... NASH RIVER BASIN: ........................ ...........TAR-PAMLICO ON -SITE SURFACE WATER AREA .............0.03 Ac. EX. IMPERVIOUS AREA:..... ......0.14 Ac. PRO. IMPERVIOUS AREA: ......... ......22.38 Ac. IMPERVIOUS AREA CALC: STREET--... ......5.15 SIDEWALK ..-- ..... 2.37 Ac. LOTS .....3,500 S.F. / LOT 14.86 Ac. TOTAL IMPERVIOUS....- ......22.38 Ac. GOVERNING AGENCIES -- PLANNING: TOWN OF SPRING HOPE 118 W. RAILROAD STREET P.O. BOX 87 SPRING HOPE, NC 27882 CONTACT MICHELLE COLLINS 252-478-5186 m. COLLINS@SPRINGHOPE. NET PUBLIC WORKS: TOWN OF SPRING HOPE 118 W. RAILROAD STREET P.O. BOX 87 SPRING HOPE, NC 27882 CONTACT MICHELLE COLLINS 252- 478- 5186 m. COLLINS®SPRINGHOPE. NET EROSION CONTROL: NC DEQ - RALEIGH REGIONAL OFFICE 3800 BARRETT DRIVE RALEIGH, NC 27609 CONTACT- BILL DENTON (919) 791-4206 bill.denton@ncdenr.gov Owner/Deve%per Axiom Development, LLC 3739 National Dr. Suite 105 Raleigh, NC 27612 Contact- Tom White 919.760.0101 twhite*pintailofs com BRYSON S RIDGE SUBDIVISION SPRING HOPE, NORTH CAROLINA MAJOR SUBDIVISION PERMITTING REVIEW SET - FEBRUARY 2, 2022 INDEX OF SHEETS CE-01 CE-02 CE-03 CE-04 CE-05 CE-06 CE-07 CE-08 CE-09 CE-10 CE-11 CE-12 CE-13 CE-14 CE-15 CE-16 CE-17 CE-18 CE-19 CE-20 CE-21 CE-22 CE-23 CE-24 D-01 D-01a D-02 D-03 D-04 D-05 D-06 D-07 CONSTRUCTION PLAT AREA ONE CONSTRUCTION PLAT AREA TWO STREET "A" AND STREET "I" PLAN + PROFILE STREET "B" PLAN + PROFILE STREET "B" + LINE A PLAN + PROFILE STREET "C" PLAN + PROFILE STREET "C" + LINE B PLAN + PROFILE STREET "D" PLAN + PROFILE STREET "E" PLAN + PROFILE STREET "E" PLAN + PROFILE STREET "F" PLAN + PROFILE STREET "F" PLAN + PROFILE STREET "G" PLAN + PROFILE STREET "H" PLAN + PROFILE DRAINAGE PLAN AREA ONE DRAINAGE PLAN AREA TWO GRADING PLAN AREA ONE GRADING PLAN AREA TWO INITIAL EC PLAN - PHASE 1 FINAL EC PLAN - PHASE 1 ROAD WIDENING PLAN WET POND SCM #1 DETAIL WET POND SCM #2 DETAIL WET POND SCM #3 DETAIL EROSION CONTROL DETAILS EROSION CONTROL DETAILS SITE NOTES AND DETAILS WATER AND SEWER DETAILS NCGO1 DETAILS NCGO1 DETAILS LIFT STATION DETAILS STORMWATER RUNOFF MAP (A) PreliminaryApproval hereby certify that the subdivision plat as depicted hereon has been granted preliminary approval pursuant the Subdivision Regulations of the Town of Spring Hope. Preliminary Approval is valid fora period of 12 months from the above date or as established under the vested rights procedure, if applicable. Ci vil Eric, ire a ering. Stocks Engineering, P.A. 801 East Washington Street P.O. Box 1108 Nashville, NC 27856 252.459.8196 (v) Contact: Mike Stocks, PE mstocksestocksengineering.com Subdivision Administrator Surveyinc, Stewart -Proctor, PLLC 319 Chapanoke Road Suite 106 Raleigh, NC 27603 919.37791855 (0 Contact- Herbie Proctor General Notes: 1. TOPOGRAPHICAL DATA PERFORMED BY STEWART-PROCTOR, PLLC. 2. THE CONTRACTOR SHALL NOTIFY AND COOPERATE WITH ALL UTILITY COMPANIES OF FIRMS HAVING FACILITIES ON OR ADJACENT TO THE SITE BEFORE DISTURBING, ALTERING, REMOVING, RELOCATING, ADJUSTING OR CONNECTING TO SAID FACILITIES. THE OWNER SHALL PAY ALL COSTS IN CONNECTION WITH ALTERATION OF OR RELOCATION OF ANY EXISTING FACILITIES. 3. ALL EXCAVATION IS UNCLASSIFIED AND SHALL INCLUDE ALL MATERIALS ENCOUNTERED. 4. ALL STRUCTURAL FILL MATERIAL SHALL BE FREE OF ALL STICKS, ROCKS, AND CLUMPS OF MUD. 5. UNUSABLE EXCAVATED MATERIALS AND ALL WASTE RESULTING FROM CLEARING AND GRUBBING SHALL BE DISPOSED OF OFF -SITE BY THE CONTRACTOR IN AN APPROVED SOLID WASTE LANDFILL. 6. LOCATION OF UNDERGROUND UTILITIES ARE APPROXIMATE AND MUST BE FIELD VERIFIED. CONTACT THE NC ONE CALL CENTER AT LEAST 72 HOURS PRIOR TO DIGGING ® 811. THE SURVEYOR HAS ONLY LOCATED THE UTILITIES THAT ARE ABOVE GROUND AT THE TIME OF FIELD SURVEY. UNDERGROUND LINES SHOWN HEREON ARE APPROXIMATE OR AS REPORTED BY VARIOUS RESPONSIBLE PARTIES. THE SURVEYOR DOES NOT GUARANTEE THAT ANY UNDERGROUND STRUCTURES SUCH AS UTILITIES, TANKS AND PIPES ARE LOCATED HEREON. 7. ALL PIPE LENGTHS ARE HORIZONTAL DISTANCES AND ARE APPROXIMATE. 8. ALL WORK SHALL COMPLY WITH ALL APPLICABLE CODES, REGULATIONS, AND/OR LOCAL STANDARDS IMPOSED BY LOCAL UTILITY, NCDOT, LOCAL MUNICIPALITIES. 9. ALL CONSTRUCTION AND MATERIALS SHALL MEET THE TOWN OF SPRING HOPE SPECIFICATIONS AND STANDARDS, LATEST EDITION. ALL WORK WITHIN NCDOT RIGHT-OF-WAY SHALL MEET THE SPECIFICATIONS AND STANDARDS OF NCDOT. 10. ALL CONCRETE PIPE IS TO BE ASTM C-76, CLASS III WITH RAM-NEK, UNLESS OTHERWISE NOTED. 11. THERE ARE NO PORTIONS OF THIS PROPERTY LOCATED IN A FLOOD HAZARD ZONE PER FEMA MAP REFERENCE NO (3720286000j) DATED 11/03/2004. 12. ALL LOT DIMENSIONS SHOWN ARE APPROXIMATE. CONSULT THE BOUNDARY SURVEY FOR ACTUAL SITE BOUNDARY INFORMATION 13. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK ZONE TRAFFIC CONTROL IN OR ADJACENT TO NCDOT RIGHT-OF-WAY. ALL SIGNS, PAVEMENT MARKINGS AND OTHER TRAFFIC CONTROL DEVICES SHALL CONFORM TO THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD), LATEST EDITION. 14. PRIOR TO PLACING CABC STONE BASE, THE CONTRACTOR SHOULD NOTIFY THE PROJECT ENGINEER TO INSPECT AND PROOF ROLL THE SUBGRADE. ANY STONE PLACED WITHOUT PRIOR APPROVAL WILL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 15. DESIGN/FIELD CONDITIONS QUITE EASILY MAY VARY FROM THAT REPRESENTED IN THE INITIAL SOILS REPORT AND/OR TOPOGRAPHICAL REPORT. ISOLATED AREAS MAY SHOW UP WEAK AND ADVERSE SOILS OR GROUNDWATER CONDITIONS MAY BE DISCOVERED THAT WERE NOT REVEALED DURING THE INITIAL SOILS INVESTIGATION. THEREFORE, THE OWNER/CLIENT IS TO BE AWARE THAT STOCKS ENGINEERING WILL NOT AND CANNOT BE HELD RESPONSIBLE FOR ANY FAILURES TO EITHER A STREET OR PARKING LOT PAVEMENT DESIGN UNLESS WE CAN BE FULLY AND TOTALLY INVOLVED IN THE CONSTRUCTION PROCESS WHICH MAY INCLUDE, BUT MAY NOT NECESSARILY BE LIMITED TO, TESTING SUBGRADE AND BASE DENSITY, ENGAGING THE DESIGN ENGINEER FOR THE EVALUATION OF THE SUBGRADE AND FOR THE OBSERVATION OF PROOF ROLLING SUBGRADE AND BASE AT VARIOUS STEPS OF CONSTRUCTION, OPPORTUNITY FOR THE DESIGN ENGINEER TO CALL IN A SOILS ENGINEER FOR CONSULTATION AND ADVICE, ETC. - STEPS WHICH TAKEN ALTOGETHER WITH THE INITIAL DESIGN SHOWN ON THE PLANS, CONSTITUTE THE COMPLETE DESIGN OF THE ROAD, STREET OF PARKING AREA (PRIVATE OR PUBLIC). THE DESIGN ENGINEER MUST BE GIVEN THE FULL LATITUDE AND OPPORTUNITY TO COMPLETE THE DESIGN BY FULLY PARTICIPATING IN THE CONSTRUCTION PROCESS. PLAN DESIGN IS A SMALL PORTION OF THE DESIGN AND CANNOT BE SEPARATED FROM THE CONSTRUCTION PROCESS IF THE OWNER'S/CLIENT'S DESIRE IS TO HAVE THE DESIGN ENGINEER STAND BEHIND THE COMPLETED DESIGNED PROJECT. 16. ALL UTILITY SERVICES, (POWER, TELEPHONE, CABLE, ETC.) ARE PROPOSED TO BE UNDERGROUND. DO NOT SOD, SEED OR MULCH DISTURBED AREAS UNTIL ALL UNDERGROUND UTILITIES HAVE BEEN INSTALLED. 17. PROPERTY IS TO BE SERVED BY PUBLIC SEWER AND WATER. 18. NO TAPS SHALL BE MADE INTO THE EXISTING WATER SYSTEM WITHOUT PRIOR 48 HOURS TO THE SYSTEMS OWNER. AN INSPECTOR FROM THE GOVERNING AUTHORITY MUST BE PRESENT AT THE TIME OF THE TAP. 19. REGULATORY SIGNS, STOPS SIGNS AND ADA SIGNS SHALL BE MANUFACTURED FROM HIGH INTENSITY REFLECTIVE MATERIALS. 20. ALL EXCESS TOPSOIL AND UNCLASSIFIED EXCAVATION IS TO BE HAULED OFF -SITE, UNLESS OTHERWISE DIRECTED BY THE OWNER. 21. ALL SITE CONSTRUCTION MUST BE INSPECTED BY THE PROJECT ENGINEER AT THE FOLLOWING STAGES: A. COMPLETION OF GRADING SUBGRADE PRIOR TO PLACING STONE BASE. B. COMPLETION OF STONE PLACEMENT PRIOR TO PAVING. C. FINAL INSPECTION WHEN ALL WORK IS COMPLETE. 22. THE SURVEYOR DID NOT VISIBLY SEE ANY CEMETERIES IN ANY OPEN AREAS UNLESS OTHERWISE NOTED. 23. THIS PROPERTY DOES NOT DEPICT ENCUMBRANCES THAT ARE FOUND DURING A THOROUGH TITLE SEARCH. 24. CONCRETE SUB SHALL BE RESPONSIBLE FOR ALL SCORE JOINTS AND EXPANSION JOINTS. 25. ALL CURB AND GUTTER TO BE 30" VALLEY CURB AND GUTTER. ALL CURB AND GUTTER WITHIN NCDOT R/W SHALL BE 30" STANDARD CURB AND GUTTER. 26. ALL CURB AND GUTTER AND SIDEWALK CONCRETE IS TO BE MINIMUM 3,000 PSI AT 28 DAYS, AIR ENTRAINED. 27. ALL DIMENSIONS ARE TO BACK OF CURB UNLESS INDICATED OTHERWISE. 28. CONTRACTOR TO FURNISH ALL PAINT STRIPING AND THERMOPLASTIC (AS REQUIRED BY NCDOT) AS SHOWN. 29. CONTRACTOR SHALL NOT POUR ANY CONCRETE BEFORE FORMS ARE INSPECTED BY THE PROJECT ENGINEER AND/OR OWNER. ANY CONCRETE THAT HAS NOT BEEN APPROVED BY THE ENGINEER AND/OR OWNER WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. 30. CONTRACTOR SHALL SAW -CUT TO PROVIDE SMOOTH TRANSITIONS WHERE EXISTING ASPHALT AND/OR CURB AND GUTTER IS TO BE REMOVED. 31. THE CONTRACTOR SHALL PROVIDE ALL THE MATERIAL AND APPURTENANCES NECESSARY FOR THE COMPLETE INSTALLATION OF THE UTILITIES. ALL PIPE AND FITTINGS SHALL BE INSPECTED PRIOR TO BEING COVERED. A MINIMUM OF 24 HOURS NOTICE SHALL BE GIVEN TO THE INSPECTOR PRIOR TO COVERING PIPE OR BLOCKINGS. 32. INFORMATION CONCERNING UNDERGROUND UTILITIES WAS OBTAINED FROM AVAILABLE RECORDS AND FIELD CONDITIONS WHEN POSSIBLE, BUT THE CONTRACTOR MUST DETERMINE THE EXACT LOCATION AND ELEVATION OF ALL EXISTING UTILITIES BY DIGGING TEST PITS BY HAND AT ALL UTILITY CROSSINGS WELL IN ADVANCE OF TRENCHING. IF THE CLEARANCES ARE LESS THAN SPECIFIED ON THE PLANS OR 12 INCHES, WHICH EVER IS LESS, CONTACT THE PROJECT ENGINEER PRIOR TO PROCEEDING WITH CONSTRUCTION. 33. THE CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND IMPLEMENTATION OF ALL REQUIRED/NECESSARY SHEETING, SHORING, AND SPECIAL EXCAVATION MEASURES REQUIRED ON THE PROJECT TO MEET OSHA, FEDERAL, STATE AND LOCAL REGULATIONS PURSUANT TO THE INSTALLATION OF THE WORK INDICATED ON CONCRETE TO BE CLASS AA AIR ENTRAINED LOW SLUMP 4500 P.S.I. . . d. d a �' 4 •., d' 2'-6" VALLEY CURB NOT TO SCALE "*a BEFORE YOU DIG, CALL a0 NORTH CAROLINA SINE CALL CENTER www.ncocc.org THE DRAWINGS. THE GOVERNING AUTHORITY, THE OWNER & STOCKS ENGINEERING ACCEPT NO RESPONSIBILITY FOR THE DESIGN TO INSTALL SAID ITEMS. 34. THE CONTRACTOR SHALL INCLUDE IN THE CONTRACT PRICE DAILY RECORD KEEPING OF THE AS -BUILT CONDITION OF ALL OF THE UNDERGROUND UTILITIES, CONSTRUCTION STAKEOUT ASSOCIATED WITHE THE PROJECT. PREPARATION OF THE NECESSARY/REQUIRED AS -BUILT PLANS TO BE SUBMITTED TO THE GOVERNING AUTHORITY AND ALL OTHER INFORMATION REQUIRED IN CONNECTION WITH RELEASE OF BONDS. 35. ALL WATER LINE AND SEWER LINE INSTALLATION SHALL CONFORM TO THE STANDARDS AND DETAILS OF THE LOCAL GOVERNING AUTHORITY AND THE STATE OF NORTH CAROLINA DEPARTMENT OF HEALTH CONSTRUCTION PERMIT. 36. THE LAND DISTURBANCE PERMIT MUST BE KEPT ON THE WORK SITE AND SHOWN UPON REQUEST. 37. THE CONTRACTOR SHALL INCLUDE IN THE CONTRACT PRICE ALL MATERIAL AND LABOR ASSOCIATED WITH THE TESTING OF THE WATER AND SEWER LINES REQUIRED BY THE GOVERNING AUTHORITY. 38. THE CONTRACTOR SHALL INCLUDE IN THE CONTRACT PRICE ANY DE -WATERING NECESSARY TO CONSTRUCT THE PROJECT AS SHOWN ON THE PLANS. 39. THE CONTRACTOR SHALL INCLUDE IN HIS CONTRACT PRICE AND ALL COST ASSOCIATED WITH PROVIDING A PROFESSIONAL ENGINEER ON SITE IF REQUIRED, DURING THE CONSTRUCTION OF THE STORMWATER MANAGEMENT FACILITIES, UNDERGROUND UTILITIES, ETC. AS REQUIRED, FOR AS -BUILT CERTIFICATION. 40. ALL GRASS, TOPSOIL AND 'BUILDING DEBRIS MATERIAL' DUMPED ONSITE SHALL BE REMOVED IN THE BASE BID PRIOR TO PLACEMENT OF STRUCTURAL FILL MATERIAL. 41. ALL GENERATED WASTE SHALL BE DISPOSED OF OFF -SITE IN AN APPROVED LANDFILL LOCATION. Additional Notes: 1. ANY DISCREPANCIES IN LAYOUT SHOULD BE BROUGHT TO THE ENGINEER'S ATTENTION PRIOR TO CONSTRUCTION. 2. WRITTEN DIMENSIONS SUPERCEDE SCALED DIMENSIONS. ALL DIMENSIONS ARE EDGE OF PAVEMENT UNLESS NOTED OTHERWISE. IF DIMENSIONS NOT SHOWN, CONTRACTOR SHALL SUBMIT RFI AND NOT ATTEMPT TO SCALE DIMENSIONS FROM DRAWINGS. 3. ALL MATERIALS, INSTALLATION, TESTING AND INSPECTION OF WATER AND SEWER UTILITIES TO MEET CURRENT STANDARDS. 4. ALL STREETS NOTED AS "PUBLIC" SHALL MEET TOWN OF SPRING HOPE MINIMUM STANDARDS. 5. ALL LOTS TO BE SERVED BY PUBLIC WATER AND PUBLIC SEWER. 6. A 10' UTILITY, DRAINAGE AND ROAD MAINTENANCE EASEMENT IS RESERVED ALONG AND ADJACENT TO ALL STREET RIGHT OF WAYS. 7. FLARED END SECTIONS ARE TO BE USED ON BOTH INLET AND/OR OUTLET ENDS OF STORM SEWER UNLESS OTHERWISE NOTED. 8. FIRE HYDRANTS ARE TO BE INSTALLED AS SHOWN ON PLANS AND SHALL BE PLACED ON THE ROW LINE. 9. MAINTAIN MINIMUM 3' COVER FOR ALL WATER PIPE. 10. WATERLINE PIPE SHALL BE CLASS 50 DIP UNLESS OTHERWISE NOTED. 11. CORPORATION STOPS SHALL BE RATED A MINIMUM OF 300 PSI. 12. WHERE WATERLINE CROSSES: 12.1. SANITARY SEWER: WATERLINE SHALL CROSS ABOUT AND MAINTAIN 2'VERTICAL SEPARATION OR 10' OF HORIZONTAL SEPARATION. IF THIS SEPARATION CANNOT MAINTAIN OR IF WATERLINE PASSED BELOW THEN BOTH WATERLINE AND SEER LINE SHALL BE CLASS 50 DUCTILE IRON PIPE FOR A MINIMUM OF 10' EACH SIDE OF CROSSING. 12.2. STORM SEWER: WHERE WATERLINE CROSSES ABOVE MAINTAIN 1' VERTICAL SEPARATION. IF THIS SEPARATION CANNOT BE MAINTAINED OF WHERE WATERLINE AND/OR SANITARY SEWER SHALL BE CLASS 50 DUCTILE IRON PIPE FOR MINIMUM OF 10' EACH SIDE OF CROSSING. 13. ALL GRAVITY SEWER LINE IS SDR 35 PVC EXCEPT AS FOLLOWS: ALL SEWER LINE LESS THAN 3' DEEP OR GREATER THAN 14' DEEP SHALL BE MINIMUM CLASS 50 DUCTILE IRON. 14. EACH PRIME CONTRACTOR PERFORMING EXCAVATIONS OR UNDERGROUND WORK SHALL BE RESPONSIBLE FOR THE LOCATION OF ANY EXISTING UTILITIES IN THE AREA OF THEIR WORK. NOTIFY THE UTILITY LOCATOR SERVICE (1-800-632-4949) AT LEAST 48 HOURS PRIOR TO COMMENCING CONSTRUCTION IN ORDER THAT EXISTING UTILITIES IN THE AREA MAY BE FLAGGED AND STAKED. CONTRACTOR SHALL USE ALL CARE NECESSARY WHEN WORKING IN AREAS KNOWN OF SUSPECTED TO CONTAIN UNDERGROUND UTILITIES, INCLUDING HAND DIGGING. 15. THE CONTRACTOR IS RESPONSIBLE FOR RELOCATION AND EXISTING UTILITIES THAT CONFLICT WITH THE PROPOSED CONSTRUCTION. IN ADDITION, THE CONTRACTOR IS RESPONSIBLE FOR REPAIR AND REPLACEMENT OF ANY UTILITIES, CURB AND GUTTER, PAVEMENT, ETC. THAT MAY BE DAMAGED DURING CONSTRUCTION. DAMAGED ITEMS SHALL BE REPAIRED TO AT LEAST THE QUALITY OF THE ORIGINAL WORKMANSHIP. THE CONTRACTOR SHALL FIELD VERIFY DEPTH OF THE EXISTING UTILITIES AND RELOCATE IF PROPOSED GRADING CAUSES UTILITY COVER TO BE LESS THAN MINIMUM REQUIRED. 16. ALL TEMPORARY EROSION CONTROL MEASURES SHALL BE INSPECTED AFTER EACH RAIN EVEN AND NECESSARY REPAIRS SHALL BE DONE AS REQUIRED. 17. STREET TREES ARE TO BE PLANTED AT REGULAR INTERVALS OF 40' WITH PREFERENCE THAT THEY BE PLACED IN FRONT OF LOT LINES. STREET TREES NOT TO BE PLANTED INSIDE 10'X70' SIGHT DISTANCE EASEMENTS AT ALL INTERSECTIONS. TREES NOT TO BE PLANTED DIRECTLY BEHIND CATCH BASINS OR WITHIN 5' OF WATER METERS OR SEWER CLEANOUTS 18. ALL DRAINAGE EASEMENTS ON PRIVATE LOTS TO BE PRIVATE AND MAINTAINED BY THE HOA. 80.00' 25' MBSL I I I I I I I I I I I I I I I I I o Im ml CD. I I LO Io of 'Lo I I I I I I I I I I I I I I I MBSL ---� L------ ------J L - - - - - - - - - 10'U77LITY EASEMENT ---------[PWA-TER-__--SSETER M S co RIW STREET TREE W. SDR-21 WATER OFF BACK OF CURB) (1.5' SS M.H,@ r------------- ---------------SS--8" SDR 35 PVC SEWER 30' ROLL CURB 40' 7' GRASS STRIP ;,... t:. , -,w.r ..., ..•.:. •.. ',ter ........ RIW '"` ' S' SIDEWALK TYPICAL LOT DETAIL SCALE: 1 " = 50' 50' R /W r� I 3 26' BB 1 5' 7' 30» 30» 1.5» SF9.5B (AT 80% BUILDOUT) 1.5» SF9.5B (CONFIRM WITH GEOTECH) SEE VALLEY CURB 2.0%� I 12 • 1/4F- DETAIL CABC 3 COMPACTED SUBGRADE - PREPARE IN ACCORDANCE WITH GEOTECHNICAL REPORT. RESIDENTIAL/LOCAL CROSS SECTION NOT TO SCALE 3 5' 1 -2.0% 1� 3 • orn �00 xI m "' N 0 Lo W z 0 D_ 12 0 U 0 Z_ W W Z_ 0 z z w Cn U o Ww w WV) Z Z c0 O 00 �r- r � Z N = U <z Z~ I.,_i U) J Ww= oco CO z C ARo� ",, HAEL S��G�`'• / Ia►3��� 11-12-2, COVER SHEET REVISIONS 5/3/22 - NCDEQ COMMENTS 5/6/22 - SPRING HOPE REV 5/13/22 - NCDEQ COMMENTS FILE NO. 2021-028 HORZ. SCALE: 1"=100' VERT. SCALE: E NONE COVER BUT GOD, WHO IS RICH IN MERCY, BECAUSE OF HIS GREAT LOVE THAT HE HAD FOR US, MADE US ALIVE WITH CHRIST EVEN THOUGH WE WERE DEAD IN TRESPASSES. YOU ARE SAVED BY GRACE! EPH. 2:4-5