Loading...
HomeMy WebLinkAboutNCC222872_Site Plan or Location Map_20220816LEGEND SYMBOLS CHARLOTTE ABANDONED EXISTING SS ASPHALT (PROFILE) BOTTOM OF BANK (TOE) BRIDGE BUILDING CHECK DAM STD 6,83 CONCRETE (PROFILE) CREEK, DITCH, OR BRANCH CURB & GUTTER EDGE OF ROADWAY EXISTING FIRE HYDRANT EXIST, WATER OR SAN, SEWER EASEMENT EXISTING IRON PIN EXISTING WATER VALVE EXISTING WATER MAIN EXISTING � SANITARY SEWER EXIST SAN SEWER MANHOLE STRUCTURE EXISTING GAS MAIN EXISTING GAS SERVICE FENCE (LABEL TYPE) — GAS VALVE GRAVEL (PROFILE) GROUND PROFILE GUARD RAIL MARSH, POND, WETLAND, OR LAKE OVERHEAD ELECTRIC POWER POLE/GUY WIRE PROPERTY LINE PROPOSED AIR RELEASE PROPOSED FIRE HYDRANT PROPOSED WATER MAIN (MARKED EVERY 100') PROP, WATER LINE EASEMENT PROP UTILITY EASEMENT PROP WATER OR SAN SEWER TAP PROP, WATER VALVE PROPOSED (E SANITARY SEWER PROP SAN SEWER MANHOLE STRUCTURE RIP — RAP ROADE'STREET R/W SEDIMENT FENCE (SILT FENCE) STD 6,62 vv��: STREET SIGN (LABEL TYPE) STORM DRAINE'CATCH BASIN, YARD AND DROP INLET TEMPORARY CONSTRUCTION EASEMENT TEMPORARY CONSTRUCTION FENCE TEMPORARY SEDIMENT TRAP STD. 6.60 TEMPORARY DIVERSION STD. 6,20 TEMPORARY STREAM CROSSING STD. 6.70 TOP OF BANK (TOB) TOWER LINE TREE & BUSH UNDERGROUND CABLE UNDERGROUND ELECTRIC UNDERGROUND TELEPHONE COMUNICATION LINE 0 E W —ss O G - GS _X WOOD GA OE �e EITHER / OR • 1+00 W i WLE e TD TD TD �T� OE uc UE UT UT UT COM COM COM RAILROAD WATER METER WM 11 01WI=I1►1aa1/:lrclU'1_11a►[.]a.741I►I�\IIIONN:11R#1:l1w7-A lIllioL7►r1MG] I1:11 arI ellicl:go] 0kylyi ma1101&3 WARI DESIGN COMPANY: PLANS PREPARED BY: STV ENGINEERS, INC. ADDRESS: 900 WEST TRADE ST., SUITE 715, CHARLOTTE, NC 28202 PHONE: (704) 372-1885 DATE DESIGN COMPLETED: — SURVEY COMPANY: SURVEYED BY: CES GROUP, LLC ADDRESS: 1974 CAROLINA PLACE DRIVE, SUITE 140, FORT MILL, SC 29708 PHONE: (704) 489-1500 DATE SURVEY COMPLETED: — DESIGN COMPANY: ADDRESS: PHONE: CONTRACTOR: SANDERS UTILITY CONTRACTORS/BRS INC. ADDRESS: 6801 BROOKSHIRE BOULEVARD, CHARLOTTE, NC 28216 PHONE: (704) 399-5600 INSPECTOR: - INSIDE CHARLOTTE: (YES ( ) NO: TOPO NO: — %rV mrER PROJECT NAME: CLTWATER PROJECT NO.: APPLICATION FOR PERMIT FOR WATER MAIN EXTENSION WT HARRIS/PLOTT ROAD WATER TRANSMISSION MAIN CPM-20-20-064-04 CHARLOTTE, NORTH CAROLINA PROJECT DESCRIPTION: CONSTRUCTION OF X LF OF 36" WATER MAIN CONNECTING TO EXISTING WATER TOWER, WITH A 12 AND 16' STREET CONNECTION, X PROPOSED FIRE HYDRANTS AND ASSOCIATED APPURTENANCES. WATER \'S_'YfS'TEM IMPR\".0VEMENTfS_' CHAR".LOTTE WATER PROJECT NO. CPM-20-20-064 WIT HARR_L'`�_/P LOTT R\\OAD WATER TRANcSAM:S SION MAIN �) _U C T: 0 N PHArSE 4/5 RELEArSAED FOR CON"TR T A, , 160+00 TO STA,., 249+85 HICKORY GROVE ELEVATED TANK 4� //,� �y ) PLAZA ROAD EXTENSION M (r l PROPOSE® 36" PLOTT ROAD TRANSMISSION N , LINE Y- _ -S� EST 29 - N .LjjI 0 \_ v SHEEN 27 i I cif SH ET 26 I i L I y I ' S FIELD CONSTRUCTION INFORMATION CONTRACT (FY XX—X): INSPECTOR: CONTRACTOR: CREW SUPERINTENDENT: CONST, START DATE: CONST, END DATE: ACTIVATION DATE: TEST DATE: INSPECTOR AS —BUILT DATE: FINAL INSPECTION DATE: MUNICIPALITY: CITY OF CHARLOTTE NCDOT PERMIT NO.: CDOT PERMIT NO.: DISTURBED AREA: 6 ACRES NSRR PERMIT NO.: MECKLENBURG CO NO.: NC DLR PERMIT NO.: SEDIMENT AND EC PERMIT NO.: DESIGNED BY: FIRM: STV ENGINEERS, INC. ENGINEER: ANDREW S. VANE, PE ADDRESS: 900 WEST TRADE STREET, SUITE 715 CHARLOTTE, NC 28202 PHONE: (704) 372-1885 THIS APPLICATION IS MADE UNDER AND IN FULL ACCORD WITH THE PROVISIONS OF CHAPTER 130A-317 OF THE NORTH CAROLINA GENERAL STATUTES, AND SUCH OTHER STATUTES AS RELATED TO PUBLIC WATER SYSTEMS. CMUD HAS BEEN GRANTED AUTHORITYTO ISSUE PERMITS FOR EXTENSION OF WATER MAINS PURSUANT TO 15A NCAC 18C.1801. THE APPLICANT AGREES THAT NO SIGNIFICANT CHANGE OR DEVIATION FROM THE PLANS AND SPECIFICATIONS APPROVED BY CHARLOTTE WATER WILL BE MADE WITHOUT THE WRITTEN CONSENT AND APPROVAL OF CHARLOTTE WATER OR ITS AUTHORIZED REPRESENTATIVE. A PROFESSIONAL ENGINEER LICENSED TO PRACTICE IN THE STATE OF NORTH CAROLINA SHALL SUBMIT A STATEMENT REFLECTING THAT ADEQUATE OBSERVATIONS DURING AND UPON COMPLETION OF CONSTRUCTION INDICATES THAT CONSTRUCTION WAS COMPLETED IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. PERMIT NO. APPROVED: CONSTRUCTION SHALL BE IN ACCORDANCE WITH CHARLOTTE WATER STANDARD SPECIFICATIONS. ,,,,,III III//// \ t N CAR O ///�� �o•'pF� S IO,L••�'y SEAL 2 025221 2 . * DREW S. DATE JOSEPH C. WILSON, PE, CHIEF ENGINEER CHARLOTTE WATER 5100 BROOKSHIRE BLVD. CHARLOTTE, NORTH CAROLINA 28216 VICINITY MAP NTS APPROVAL SEAL CAROl�'� �`T i SEAL _ 025221 _ •��'•;;YG I NE- �*DREW N F��TT= S �1111 11ll000 N.C.P.E. SUMMARY OF WATER MAINS & HYDRANTS SIZE LENGTH SIZE LENGTH 36—INCH 8,984 EE 16—INCH 285 EE TOTAL NO. OF HYDRANTS: 7 TOTAL NO. LOTS SERVED: N/A PROJECT NAME: VVT HARR6/PEOTT ROAD VVATER TRANSMISSION MAIN JOB NO: CPM-20-20-064 DATE OF ACTIVATION: DATE AS BUILT: BY: