Loading...
HomeMy WebLinkAboutNCC222650_Site Plan or Location Map_20220810PAKCEL DATA Alamance County Tax Information (Per Alamance County GIS) Parcels Included in this Project: 3 Parcel I : Parcel ID: 1203G I GPIN: 88G30001 22 Property Address: Prank S Holt Drive, Burlington, NC Township: Burlington Property Area: 2.002 Acres ± City Of Burlington Zoning: MI - Medium Industrial AHOD - Airport Horizontal Overlay District (Per City of Burlington GIS Zoning Map) Parcel 2: Parcel ID: 1 20303 GPIN: 88G3GG2 1 97 Property Address: Frank 5 Holt Drive, Burlington, NC Township: Burlington Property Area: 2.000 Acres ± City of Burlington Zoning: MI - Medium Industrial AHOD - Airport Horizontal Overlay District (Per City of Burlington GIS Zoning Map) Parcel 3: Parcel ID: 1 203G5 GPIN: 8863GG527G Property Address: Prank S Holt Drive, Burlington, NC Township: Burlington Property Area: 2.523 Acres ± City of Burlington Zoning: MI - Medium Industrial AHOD - Airport Horizontal Overlay District (Per City of Burlington GIS Zoning Map) MINIMUM BUILDING SETBACKS: City of Burlington Zoning: MI - Medium Industrial Per City of Burlington Zoning Ordinance, Section 3.1 1: Street setback - 40 feet (On corner lots, may be reduced by 50 % on the long side of the lot) Side setback - 5 feet Side setback - 1 5 feet abutting a residential or OI zoning Rear setback - 30 feet EROSION CONTROL LEGEND LIMITS OF DISTURBANCE SILT FENCE CONSTRUCTION ENTRANCE DIVERSION DITCH BAFFLES SILT FENCE OUTLET (SFO) TF TREE FENCE �� INLET PROTECTION RIP RAP OUTLET PROTECTION An Erosion Control Permit is required for projects within the City of Burlington having a disturbed area greater than I acre. This project proposes to disturb more than one acre. Submit erosion control plans if required to City of Burlington Engineering following TKC Approval. Erosion Control Plans were not reviewed by engineering as part Of TKC. CONTRACTORS NOTES: I . The contractor shall verify the location of all existing utilities prior to beginning construction. Locations of existing utilities Shown on the plan are based on the best available information, but can only be considered approximate. 2. The City of Burlington shall review and approve construction drawings prior to construction. Any conflicts should be reported to the project engineer immediately for review prior to beginning construction. It shall be the owner's responsibility to obtain all required approvals and permits from agencies governing this work prior to any construction. 3. It shall be the responsibility of the owner to obtain all applicable permits, complete testing and inspections, and obtain proper certification that the proposed construction was installed in accordance with the approved plans and speclfications. 4. All underground utilities are to be installed and tested prior to the placement of any base course stone, concrete (sidewalks, curbs, Slabs, etc.), or pavement. 5. Any fill material imported into or exported from the site Shall originate from or be disposed of at a properly permitted location. All structural fill material and bearing Soils shall be tested and certified by the project geotechnical engineer. G. Cleanouts in traffic areas shall be placed inside traffic rated mini manholes (typ.) GENEKAL NOTES: I . All utility installation, construction methods, and materials shall conform to the City of Burlingt Standard Specifications and Details, North Carolina Erosion and Sediment Control Practice Standard Specifications, Alamance County Standard SpeclfICatlons, and the NC Plumbing Code. 2. Boundary, topographic, and existing feature information obtained from Alamance County GIS topographical data and from Alamance County plat book G4 page 148. 3. Existing Conditions are shown based on field surveys and best available record at the time of tl plan. Any discrepancies Shall be reported to the engineer immediately. 4. Exact Size and location of utIlltle5 are to be field verified prior to construction. 5. Contact the project engineer immediately with any conflicts regarding the design or con5tructic of the project. All field adjustments shall be verified by the project engineer prior to construction. G. Construction and location Of sidewalks, slopes, landings, approaches, ramps, and accessible routes Shall be in accordance with the ANSI 2009 Handicap code or latest Accessibility Code rev151( 7. Contractor shall contact project engineer to observe formwork for site curb, concrete sidewall and other Items as well as string lines or other controls prior to the placement of concrete, setting base course stone, or the placement of asphalt. 8. Compaction of fill materials, approval of residual subgrade, soil proof rolls, stone placement, and/or other materials testing functions shall be in accordance with the project geotechnical engineer guidance, specifications, recommendations, and testing standards. Plan Prepared for: M * P Developments, Inc. PO Box 2 104 Burlington, NC 272 1 G Contact: Christopher Powell - 33G-350-9752 TSB-1 Skimmer Sediment Basin Basin: 1 Drainage Area = 5.92 ac Q25 = 0.45 x 5.92 ac x 8.20 in/hr = 21.83 cfs Required Proposed C@ 555.0 Surface Area: 7,094 sf 8,053 sf Volume: 10,648 cf 14,457 cf Length: N/A PER PLAN Width: N/A PER PLAN Normal Pool Depth: 2 ft 2 ft Floor Elevation: N/A 553.0 Weir Elevation: N/A 556.0 Weir Width: 21 ft 22 ft Dam Elevation: N/A 558.0 Skimmer: 2.5 in 2.5 in Orifice: r = 1.1 in, dia = 2.2 in r = 1.1 in, dia = 2.2 in THIS PROJECT IS LOCATED IN THE CAPE FEAR RIVER BASIN TRIBUTARY TO GUM CREEK (W5-V,N5W) TEMPORARY DIVERSION DITCH SCHEDULE CURVE TABLE CURVE CHORD 5EARING CHORD LENGTH RADIUS ARC LENGTH C I N 78°02'47" E 233.44' 2G5G. I G' 233.52' C2 N 7G°34' 1 4" E 45.06' 1 358.29' 45.08' C3 S GG°371 1 " E 34.2 1' 30.00' 3G.40' C4 5 G8°04'2 I " E 70.65' G0.00' 75.79' C5 N 5G° 1002" E 40.00' Go.00' 40.76' DITCH WIDTH (ft) DEPTH (ft) Q25 (cfs) SLOPE (%) VELOCITY (fps) FLOW DEPTH (ft) SHEAR STRESS (psf) LINER PERMISSABLE SHEAR STRESS (psf) SAFETY FACTOR TD-1 0.00 1.50 9.6 5.0% 6.64 0.85 2.65 NAG - C125BN (or equivalent) 2.8 1.06 TD-2 0.00 1.50 8.6 4.1% 5.86 0.86 2.19 NAG - C125BN (or equivalent) 2.8 1.28 U5-E�EXISTING 4 - PRO7L�TY 5� / TEMP. / LINE DITCH FOR ay CONSTRUCTION CLEARWATER DIVERSION R9h�' / ENTRANCE, SEE - EXTEND DITCH T �2' SG� DETAIL'SE-5' CFRUCTION / ENTRANCE TEMP. CONSTRUCTION AT ELEVATION 5G7 ENTRANCE CULVERT: 1 8" HDPE 401f. @ I % R DRIVEWAY CREST 5G7.5 GO' 3 - �1 �01t 0, E C G 1� 5° �ra 60, p�b��G �w GG G Q G / ` i / I I RROP 2 31W x 161 x 22" Th. / I RAP ARMOR Uj�O �� C°C4j�b h�jCo �/7 Q D50= 1311, CLASS 'B' / U RIP -RAP w/ G oz. / = I GEOTEXTILE FABRIC co UNDER O / O IW W �' o w rn Q w 2.5" FAIRCLOTH / ex SKIMMER TO TO'Llf I 0 L CONNECTION TO 0 LF I CV _\ x 4" SCH. 40 PVC RAI / �h PIPE, GRADE PIP / w I� �I� °� o I 6 '5G = J TEMPORARY 4 If. q I I� a _562 12" LEARWATER / I I 6 / CU ERT o I^ F 3) 1 In 5G5 / INV. Out 5 2 / I F� / Min. Cover I' / _ I ¢ I cn x 22 �S . i� 50- O 3 - � s -� ° -- �I �0 55 \ I � o 549 WATER SURFACE EL V.: 555.0 RROP- SILT \ Sg� 3 U x OIL x 9" Th OUTLET 5' 1 DE TOP CLASS 'A' R P- P TYP. OF V A 58.0 wl G oz. GEOTEXT E 2H: V M On P DEVELOPMENTS, IN FABRIC UNDER / SLOPE (TYP. PARCEL ID: 1 203 I� 3H: I V MAX. INSIDE D M) USE: VA T /I DE / S PE (TYP. / CITY OF BU GTON ZONING: MI SPILLWAY TSIDE M) / ELEV Additional Borrow / Waste Note: If the Same person conducts the land -disturbing activity and any related borrow or waste activity, the related borrow or waste activity shall constitute part of the land -disturbing activity unless the borrow or waste activity 15 regulated by the Division of Solid Waste Management. If the land -disturbing activity and any related borrow or waste activity are not conducted by the same person, they Shall be considered separate land disturbing activities and must be permitted either through the Sedimentation and Pollution Control Act as a one -use -borrow site or through the Mining Act. Site Soils Classlflcation: Unclassified. Classification of near surface soils shall be made per owner's geotechnical engineering recommendations based on the evaluation of exposed Subgrade 50115. SOIL EROSION & SEDIMENTATION CONTROL PLANS APPROVED BY David B. Bowman, PE DATE 7/14/2022 �S 60 I II I \ o . CH PAL CELMARKER D RI 2103GRK. LLC / 4 /USE: WAREHOUSE CITY OF INGTON ZONING: MI 33.8 N 55°43' 4 - S�6 5G2 r \ 1 L [L O O� Cc o � � t n ro �582- <1\ m h� I O J 47 / r Do 51 D O R REEEL ID: 1 / / SILT USE: RESIDENTIAL FENCE, CITY OF 5LJ TON ZONING: I TYP. / � / I EROSION CONTROL NOTES: Proposed Disturbed Area = 5.92 Acres (257,G77 sf) I . Limits of Disturbance shall be property lines, silt fencing, temporary diversion ditches, or as shown on plan. 2. In areas where the property boundary, disturbance limits, and/or silt fencing are parallel and overlap, lines are offset to provide clarity. 3. This site proposes to disturb more than one acre. An erosion and sedimentation control permit is required for disturbed areas of one acre or more. (City of Burlington Sedimentation and Erosion Control Jurisdiction) 4. Additional erosion control measures will be installed during construction in order to control erosion if deemed necessary by on -site inspection. 5. All erosion control measures shall be inspected once every 7 calendar days or after a rainfall event having precipitation grater than 112 inch in any 24 hour period. The inspection shall be documented in writing, and damaged or ineffective measures be repaired or replaced as needed. G. A self -inspection must be made of the project after each phase and documented in writing. This self inspection will be performed in addition to the NPDE5 self monitoring report required by the General Permit as described above. 7. All erosion and sediment control deVICC5 shall be properly maintained during all phases of construction until the completion of all construction activities and / or contributing areas have been stabilized. Existing measures may require adjustment or modification and additional control measures may be required in order to control erosion and/or off -site sedimentation if determined necessary by on site inspection. READ THE PERMIT - READ THE PLANS CALL BEFORE YOU DIG! IT5 THE LAW ULOCO North Carolina One Call Center 1-800-632-4949 01 100, 2001 Graphic Scale Scale: I " = 50' G-02-22 JAIL ENGIN`_ER5 COIv LAE�T� z -I 00 0z-J ( L/OCL- w U 7 O�.•'••S SI•• ! � C-1939 c � �z 'zAm o� v v 0 v Ca W w a