Loading...
HomeMy WebLinkAboutNCG030394_Monitoring Report_20220714per ions xcellence inc. June 2022 Mr. James Moore NCDEQ Division of Energy, Mineral, and Land Resources Mooresville Regional Office 610 East Center Avenue, Suite 301 Mooresville, North Carolina 28115 Subject: Report of Stormwater Sampling— 2Q 2022 Commercial Fabricators, Inc. 2045 Industrial Drive Newton, Catawba County, North Carolina NCDEQ Certificate of Coverage #NCG030394 Dear Mr. Moore: 0 IL GOO�G y'Vv r G G> O Attached is a stormwater sampling report for the subject facility. If you have any questions regarding this submittal, please contact the undersigned at 336-382-6849. Sincerely, Jeff Gerlock, L.G. NC Licensed Geologist #1141 Attachments — SW Discharge Monitoring Report Form Cc: Mr. John R. Tucker, Jr, Commercial Fabricators Operations Excellence, Inc., 2235-E Lewisville-Clemmons Road, Clemmons, North Carolina 27012 — 336-766-2913 NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report (DMR) Form for NCG030000 Metal Fabrication Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMOVoload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DMA Regional Office. Certificate of Coverage No. NCG03 0394 Person Collecting Samples: J rloc G, °; Facility Name: Commercial Fabricators Laboratory Name: Meritech Facility County: Catawba Laboratory Cert. No.: 165 i Discharge during this period: El Yes 0 No (if no, skip to signature and date) 7 Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceeds lces? ® Yes ®✓ No If so, which Tier (I, II, or III)? A copy of this DMR has been uploaded electronically via https://edocs.deg.nc.gov/Forms/SW-DMR Date Uploaded: June 2022 _ ®✓ Yes No Analytical Monitoring Requirements for Outfalls with Industrial Activities — Benchmarks in (Red) Parameter Parameter Outfall OF-1 Outfall OF-2 Outfall Outfall Outfall Code N/A Receiving Stream Class C C N/A Date Sample Collected MM/DD/YYYY 5-27-2022 5-27-2022 46529 24-Hour Rainfall in inches 0.56 0.56 C0530 TSS in mg/L (100 or 50*) 3 <2.5 00400 pH in standard units (6.0— 9.0 FW, 6.34 6.61 6.8-8.5 SW) Copper, total recoverable in mg/L 01119 (0.010 FW, 0.0058 SW) 0.003 0.006 Lead, total recoverable in mg/ L 01051 (0.075 FW, 0.22 SW) <0.010 <0.010 Zinc, total recoverable in mg/ L (0.126 01094 FW, 0.095 SW) 0.151 0.137 Chemical Oxygen Demand (COD) in 00340 mg/L(120) <15 <15 00552 Non -Polar Oil & Grease in mg/L (15) <5 <5 * Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA) have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L FW (Freshwater) SW (Saltwater) Notes (optional): "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." of Permittee or Delegated AXthorized individual jtucker@commfab.com Email Address 7XI Igo a �- Date 828-465-1010 Phone Number