Loading...
HomeMy WebLinkAboutSW5220101_Plansheet (C2.00) - Proposed Conditions/Site Plan_20220728HARDEE'S MONUMENT SIGN (10' TALL MAX. & MAX. 40 SF) PERMITTED BY SIGN COMPANY \ \ \ 24" CURB AND GUTTER (TYP.) SEE SHEET C7.00 FOR OFFSITE / \ ROAD IMPROVEMENTS EX. CURB AND 4\ / °' 60'' A \ V A V A \ GUTTER (TYP) 1.5'R \\ \\\\\ \ �F�, \ 1 \\ \\ 00, \� \ 10 \< 24" CURB AND GUTTER 4' STREETYARD\ \� (TYP.) \ \> TIE TO EXISTING 30" STANDARD CURB AND GUTTER (TYP.) 3'R TIE TO EXISTING / / 8' 5' CONCRETE Q�Q- ASPHALT (TYP.) / SIDEWALK Nvn^ �• \ \\ 25R C 0 41 AC 5' CURB & GUTTER l� / / ® ® 8"X8" BLACK TIL TRANSITION1Z4 5 SITE LIGHTS \ \ °/ WHEELSTOPS / (TYP) (DESIGN BY OTHERS) O \ \ \ \ / 15'R / / (TYP.) SEE NOTE #14 20'R 5'R / J / © ACCESSIBLE PARKING \ \ \ \ \ \ SIGN (TYP.) \ \ 1'R CONCRETE TURN 4.5' 20'R \ 25'R \\\\ DOWN SIDEWALK 15' R G QO ,1O EX. EDGE OF �Q / PAVEMENT / 4' STREEI L E: N 0 N DRIVE—THRU /s. CLEARANCE BAR 20'R 0201 1'R 24" CURB AND GUTTER (TYP.) 20'R 5' CONCRETE SIDEWALK — DDF-AAP_N11 I R(IARn (TYP.) BUILDING 4*_ d�( 24" CURB AND GUTTER 6• 21682 SF 02 (TYP.) 40 SEATS Op \ \ \ \ \ PROPOSED 30" \ \\ \ CURB & GUTTER \\ \ 3_5-%� j / / / �— 24" CURB AND GUTTER (TYP.) 2 — 10'X50' TRUCK AND TRAILER PARKING \ TIE TO EXISTING 30" STANDARD \ \\ \ \ CURB AND GUTTER (TYP.) \ \ \ \\\ \ \ PROPOSED PROPERTY LINE \ \ \ O / \ 0.66 AC SITE LEGEND T xx TYPE Q TYPE © TYPE 000000•••• SITE PLAN NOTES: SIGNAGE YARD LIGHTS POWER POLE TRAFFIC DIRECTIONAL ARROW ACCESSIBLE PARKING STALL VAN ACCESSIBLE PARKING STALL PARKING SPACE COUNT ACCESSIBLE RAMPS ACCESSIBLE ROUTE PROPERTY LINE RIGHT—OF—WAY LINE LOT LINE EASEMENT LINE 1. ALL CONSTRUCTION SHALL CONFORM TO THE LATEST LOCAL AND STATE MUNICIPALITY AND/OR NCDOT STANDARDS AND SPECIFICATIONS AS APPLICABLE. 2. ALL DIMENSIONS SHOWN ON SITE PLAN ARE MEASURED TO FACE OF CURB UNLESS OTHERWISE NOTED. 3. CONTRACTOR SHALL MAINTAIN AN "AS -BUILT" SET OF DRAWINGS TO RECORD THE EXACT LOCATION OF ALL PIPING PRIOR TO CONCEALMENT. DRAWINGS SHALL BE GIVEN TO THE ENGINEER UPON COMPLETION OF THE PROJECT WITH A COPY OF THE TRANSMITTAL LETTER TO THE OWNER. 4. EXISTING IMPROVEMENTS DAMAGED DURING CONSTRUCTION SHALL BE REPLACED/RESTORED TO THEIR ORIGINAL CONDITION AND TO THE SATISFACTION OF THE OWNER, BY THE CONTRACTOR RESPONSIBLE FOR THE DAMAGE. 5. THE CONTRACTOR SHALL NOTE THAT THE DRAWINGS MAY NOT SHOW EVERY OFFSET, TRANSITION, FITTING, ETC. THAT MAY BE REQUIRED. THE CONTRACTOR SHALL INSTALL SUCH STANDARD APPURTENANCES AS REQUIRED TO CLOSELY FOLLOW THE GRADES AND ALIGNMENTS DEPICTED ON THE PLANS. 6. CONTRACTOR SHALL NOTIFY "NCDOT" (811) OR 800-632-4949 AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NCDOT". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. 7. CONTRACTOR IS RESPONSIBLE FOR COORDINATING CONSTRUCTION ACTIVITIES WITH THE APPROPRIATE UTILITY COMPANIES FOR ANY REQUIRED RELOCATIONS (I.E. POWER POLES, TELEPHONE PEDESTALS, WATER METERS, ETC.). 8. PRIOR TO BEGINNING CONSTRUCTION BEYOND EROSION CONTROL MEASURES, THE GENERAL CONTRACTOR SHALL SCHEDULE AND ATTEND A PRE -CONSTRUCTION CONFERENCE WITH THE LOCAL AND STATE MUNICIPALITY PUBLIC WORKS DEPARTMENT AND A REPRESENTATIVE OF THE ENGINEER AND OWNER. THE PURPOSE OF THIS MEETING IS TO REVIEW THE SPECIFIC COMPONENTS OF THE PLAN AND OPERATION OF THE FACILITIES DURING CONSTRUCTION. 9. ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ENGINEER IF ANY DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION, FOR NECESSARY PLAN OR GRADE CHANGES. NO EXTRA COMPENSATION SHALL BE PAID TO CONTRACTOR FOR ANY WORK DONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS IF SUCH NOTIFICATION HAS NOT BEEN GIVEN. 10. PEDESTRIAN EXISTING ROUTES AND ALTERNATE PEDESTRIAN ROUTES DURING CONSTRUCTION WILL BE REQUIRED TO BE COMPLIANT WITH THE PUBLIC RIGHTS OF WAY ACCESSIBILITY GUIDELINES (PROWAG), 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN AND THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD). 11. TYPICAL PAVEMENT SECTION DETAILS ARE SHOWN WITHIN THIS PLAN SET AND INTENDED TO BE A MINIMUM PAVEMENT SECTION REQUIREMENT. THE CURRENT GEOTECHNICAL REPORT SHALL OVER -RIDE ALL TYPICAL PAVEMENT SECTIONS SHOWN, IF THE GEOTECHNICAL ENGINEER DEEMS A HEAVIER SECTION IS REQUIRED. 12. EQUIPMENT AND PRODUCTS OTHER THAN THOSE SPECIFIED MAY BE USED PROVIDED APPROVAL HAS BEEN OBTAINED FROM THE OWNER IN WRITING PRIOR TO ORDERING OR INSTALLATION. THE CONTRACTOR SHALL WAIVE ANY CLAIM FOR ADDITIONAL COST RELATED TO SUBSTITUTION OF ALTERNATE EQUIPMENT. 13. IF UNFORESEEN CONDITIONS DEVELOP DURING CONSTRUCTION, REFER TO THE LATEST VERSION OF THE LOCAL AND STATE MUNICIPALITY SPECIFICATIONS AND STANDARDS 14. FOR 8"X8" BLACK TILE OR RESINOUS FLOOR (SILIKAL) , SEE ARCHITECTURAL DRAWINGS FOR DETAILS AND BID ALTERNATES. W GRAPHIC SCALE 0 10 20 40 1 inch = 20 ft. PRELIMINARY DRAWING - NOT RELEASED FOR CONSTRUCTION 'J McADAMS The John R. McAdams Company, Inc. 2905 Meridian Parkway Durham, NC 27713 phone 919. 361. 5000 fax 919. 361. 2269 license number: C-0293, C-187 www.mcadamsco.com CLIENT BODDIE-NOELL ENTERPRISES, INC. P.O. BOX 1908 ROCKY MOUNT, NC 27802 Contact PHONE: 252. 937. 2800 W W � � W Z.j a Q O Q z Z V z m � 0 M W LLI Z 06 000 V cV `,,,, I ll% 11 a #,,',, �-%* -N CARP ''.. •......, , SEAL _ 20744 G I NEF'�' • L. SM •�•����..�� REVISIONS NO. DATE 1 2 3 4 5 6 PLAN INFORMATION PROJECT NO. 2021110321 FILENAME 2021110321-S1 CHECKED BY RW DRAWN BY WHM SCALE 1" = 20' DATE 6. 17. 2022 SHEET SITE PLAN C goo