HomeMy WebLinkAboutSW3220402_Plansheet 2L-5&6 - Grading_Drainage Plan_20220627STR CO URE TYPE NCDO#T STD RIM DEPTH 7-100 FES 310.03 7-101 DI- 840.14 727.00' 4.50' 7-102 DI- 840.14 733.00' 5.70' 7-103 DI- 840.14 733.00' 4.50' 7-104 DI- 840.14 737.00' 7.10' 7-105 DI- 840.14 739.00' 8.20' 7-106 DI 840.14 737.00' 4.90' 7-107 DI 840.04 737.00' 3.70' 7-200 FES 310.03 7-201 Cl- 840.02 732.31' 9.81' 7-202 Cl- 840.02 732.28' 5.48' 7-203 Cl- 840.02 735.71' 5.41' 7-204 Cl- 840.02 738.19' 6.59' 7-205 Cl- 840.02 738.20' 6.20' 7-206 Cl- 840.02 743.36' 8.06' 7-207 DI- 840.14 739.00' 3.00' 7-208 Cl- 840.02 743.48' 4.28' 7-209A Cl- 840.02 748.21' 4.21' 7-209B Cl- 840.02 755.32' 3.72' 7-210 Cl- 840.02 755.62' 3.62' 7-211 Cl- 840.02 737.96' 5.36' 7-212 Cl- 840.02 738.66' 5.16' 7-213 Cl- 840.02 738.64' 4.74' 7-214 Cl- 840.02 739.49' 4.89' 7-215 Cl- 840.02 740.60' 5.00' 7-216 DI- 840.14 740.50' 4.00' 7-217 DI- 840.14 743.00' 5.00' 7-218 DI- 840.14 745.00' 3.90' 7-219 DI- 840.14 747.00' 3.70' 7-220 Cl- 840.02 741.72' 4.72' 7-221 Cl- 840.02 741.72' 4.32' 7-222 Cl- 840.02 742.65' 4.65' 7-223 7-224 DCI- 840.02 743.31' 3.81' DCI- 840.02 743.29' 3.39' 7-225A Cl- 840.02 744.30' 4.00' 7-225B Cl- 840.02 747.39' 4.19' 7-226 Cl- 840.02 747.39' 3.79' 7-300 HW- 838.01 7-301 Cl- 840.02 727.56' 5.38' 7-302 Cl- 840.02 728.22' 5.67' 7-303 7-304 Cl- 840.02 840.02 729.03' 6.06' 5.89' Cl- 728.99' 7-305 Cl- 840.02 729.97' 6.57' 7-306 Cl- 840.02 729.98' 6.38' 7-307 Cl- 840.02 729.92' 3.52' 7-308 Cl- 840.02 732.36' 5.56' 7-309 DI- 840.14 733.00' 4.30' 7-310 DI- 840.14 733.00' 3.60' 7-311 Cl- 840.02 732.33' 4.13' 7-312 Cl- 840.02 735.24' 5.94' 7-313 Cl- 840.02 737.77' 7.08' 7-314 DI- 840.14 739.00' 5.20' 7-315 D 1 840.14 749.00' 4.20' FROM INVERT INVERT TO PIPE LENGTH SLOPE REMARKS STRUCTURE UP DOWN STRUCTURE SIZE 7-101 722.50' 722.00' 7-100 15" 28' 1.79% RCP, O-RING 7-102 727.30' 723.40' 7-101 15" 165' 2.36% RCP, O-RING 7-103 728.50' 727.50' 7-102 15" 156' 0.64% RCP 7-104 729.90' 728.70' 7-103 15" 196' 0.61 % RCP 7-105 730.80' 730.10' 7-104 15" 115' 0.61 % RCP 7-106 732.10' 731.00' 7-105 15" 174' 0.63% RCP 7-107 733.30' 732.30' 7-106 15" 166' 0.60% RCP 7-201 722.50' 722.00' 7-200 30" 54' 0.93% RCP, O-RING 7-202 726.80' 726.60' 7-201 30" 25' 0.82% RCP 7-203 730.30' 727.00' 7-202 30" 115' 2.88% RCP 7-204 731.60' 730.50' 7-203 30" 44' 2.49% RCP 7-205 732.00' 731.80' 7-204 30" 25' 0.81 % RCP 7-206 735.30' 734.50' 7-205 15" 90, 0.89% RCP 7-207 736.00' 735.50' 7-206 15" 72' 0.69% RCP, CLASS IV 7-208 739.20' 739.00' 7-206 15" 24' 0.84% RCP 7-209A 744.00' 739.00' 7-206 15" 60' 8.31 % RCP 7-209B 751.60' 744.20' 7-209A 15" 143' 5.17% RCP 7-210 752.00' 751.80' 7-209B 15" 27' 0.75% RCP 7-211 732.60' 732.20' 7-205 24" 45' 0.89% RCP 7-212 733.50' 732.80' 7-211 24" 58' 1.20% RCP 7-213 733.90' 733.70' 7-212 15" 24' 0.82% RCP 7-214 734.60' 733.70' 7-212 24" 83' 1.08% RCP 7-215 735.60' 734.80' 7-214 24" 15" 104' 0.77% RCP 7-216 736.50' 735.80' 7-215 132' 0.53% RCP 7-217 738.00' 736.70' 7-216 15" 90, 1.45% RCP 7-218 741.10' 738.20' 7-217 15" 225' 1.29% RCP 7-219 743.30' 741.30' 7-218 15" 80' 2.50% RCP 7-220 737.00' 735.80' 7-215 18" 105' 1.14% RCP 7-221 737.40' 737.20' 7-220 15" 25' 0.81 % RCP 7-222 738.00' 737.20' 7-220 18" 93' 0.86% RCP 7-223 7-224 739.50' 739.90' 738.20' 739.70' 7-222 7-223 18" 223' 24' 0.58% 0.82% RCP RCP, CLASS IV 15" 7-225A 740.30' 739.70' 7-223 7-225A 15" 75' 0.80% RCP 7-225B 743.20' 740.50' 15" 77' 3.52% RCP 7-226 743.60' 743.40' 7-225B 15" 25' 0.82% RCP n _c STORM DRAINAGE SYSTEM NOTES: 1. REFER TO NCDOT STANDARD DETAIL 300.01, 1/2L-16 FOR METHOD OF PIPE INSTALLATION. 2. STORM DRAINAGE SLOPES SHOWN ON THIS PLAN ARE FOR CONTRACTOR REFERENCE ONLY. 3. ALL CURB INLET RIM ELEVATIONS ARE MEASURED AT LIP OF EDGE OF PAVEMENT. 4. THE CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTING THE STORM DRAINAGE TO THE INVERTS SHOWN ON THIS PLAN. 5. ALL SLAB TYPE STRUCTURES ARE OPEN ON ALL 4 SIDES. 6. ALL GRATED DROP INLET RIM ELEVATIONS ARE MEASURED AT TOP OF GRATE, SLAB DROP INLETS MEASURED AT THROAT OPENING. 7. ALL RCP TO BE CLASS III UNLESS OTHERWISE NOTED 8. ALL FLARED END SECTION'S SLOPE AND ORIENTATION ARE TO BE THE SAME AS THE ATTACHED OUTLET PIPE. THE LENGTH OF ALL FLARED END SECTIONS ARE INCLUDED IN THE OUTLET PIPE'S LENGTH. 9. JB, JUNCTION BOX SHALL BE PER NCDOT 840.34. MH, MANHOLE SHALL BE PER NCDOT 840.52. 10. ALL CURB INLETS (CI) OR DOUBLE CURB INLETS (DCI) SHALL BE PER NCDOT DETAIL 840.02 & 840.03 (CONCRETE INLET WITH CAST IRON GRATE AND HOOD), UNLESS NOTED OTHERWISE. ALL DROP INLETS (DI) SHALL BE SLAB OR GRATE TYPE INLETS PER NCDOT DETAIL 840.04 & 840.14, UNLESS NOTED OTHERWISE. 11. ALL PROPOSED SEWER AND WATER ARE TO BE CONSTRUCTED WITHIN THE STREET ROW EXCEPT NEAR BRIDGE WHERE THE SEWER AND WATER ARE WITHIN AN PROPOSED EASEMENT. SEE PLAN FOR EASEMENT NOTE: SEE SHEET 2L-6 FOR GRADING &STORM DRAINAGE NOTES Project Manager HVN Drawn By RJ/LG Checked By HVN Date 8/22/2019 Project Number 17031 Know what's below Call before you dog. REVISIONS: I 1 / COS r O No. Date (M/D/Y) By Description 1 3-11-2020 RT PER TOWN'S AND NCDENR'S WQ FIRST REVIEW COMMENTS 2 6-12-2020 RT PER NCDENR DEQ's-SECOND-REVIEW COMMENTS 3 2-19-2021 RT PER TOWN'S SECOND AND NCDENR'S WQ THIRD REVIEW COMMENTS 4 5-7-2021 RT REVISION DOES NOT EFFECT THIS SHEET 5 2-4-2022 RT/TC PER TOWN'S THIRD REVIEW COMMENTS FROM STRUCTURE TYPE STIR # RIM DEPTH 7-316 D17 840.14 751.00' 4.20' 7-317 DI- 840.14 754.00' 4.20' 7-318 DI 840.14 756.00' 4.00' 7-319 Cl- 840.02 740.54' 8.99' 7-320 Cl- 840.02 742.84' 10.82' 7-321 Cl- 840.02 747.61' 4.09' 7-322 Cl- 840.02 752.32' 4.37' 7-323 Cl- 840.02 754.05' 4.05' 7-324 Cl- 840.02 754.05' 3.65' 7-325 Cl- 840.02 742.85' 10.48' 7-326 Cl- 840.02 742.10' 9.26' 7-327 Cl- 840.02 742.10' 5.48' 7-328 Cl- 840.02 743.16' 9.65' 7-329 DI- 840.14 741.00' 3.50' 7-330 Cl- 840.02 742.34' 7.73' 7-331 Cl- 840.02 740.30' 4.93' 7-332 DCI- 840.02 739.57' 3.82' 7-333 DI- DCI- Cl- DI- 840.14 840.02 840.02 740.00' 739.64' 727.56' 3.50' 7-334 7-335 3.74' 4.96' 7-336A 840.14 729.00' 4.20, 7-336B DI- 840.14 732.00' 5.00' 7-337 DI- 840.14 734.00' 5.70' 7-338 DI- 840.14 738.00' 8.00' 7-339 DI- 840.14 739.00' 7.20' 7-340A DI- 840.14 739.00' 5.50' 7-340B MH 840.52 743.00' 8.60' 7-340C DI- 840.04 739.00' 3.48' 7-400 FES 310.03 723.96' 6.62' 7-401 DCI- 840.02 726.32' 5.32' 7-402 DCI- 840.02 726.52' 4.02' FROM STRUCTURE INVERT UP INVERT DOWN TO STRUCTURE PIPE SIZE LENGTH SLOPE 7-316 746.80' 745.00' 7-315 18" 135' 1.33% 7-317 749.80' 747.00' 7-316 18" 145' 1.93% 7-318 752.00' 750.00' 7-317 18" 137' 1.46% 7-319 731.55' 730.89' 7-313 24" 110, 0.60% 7-320 732.02' 731.75' 7-319 24" 46' 0.59% 7-321 743.52' 738.00' 7-320 15" 88' 6.25% 7-322 747.95' 743.72' 7-321 15" 89' 4.74% 7-323 750.00' 748.15' 7-322 15" 89' 2.09% 7-324 750.40' 750.20' 7-323 15" 25' 0.81 % 7-325 732.37' 732.22' 7-320 24" 25' 0.61 % 7-326 732.84' 732.57' 7-325 24" 45' 0.61 % 7-327 736.62' 736.47' 7-326 15" 25' 0.61 % 7-328 733.51' 733.04' 7-326 24" 79' 0.60% 7-329 737.50' 736.80' 7-328 15" 111' 0.63% 7-330 734.61' 733.51' 7-328 24" 182' 0.60% 7-331 735.37' 734.61' 7-330 24" 128' 0.60% 7-332 735.75' 735.37' 7-331 15" 63' 0.60% 7-333 736.50' 735.95' 7-332 15" 111' 0.50% 7-334 735.90' 735.75' 7-332 15" 23' 0.65% 7-335 722.60' 722.40' 7-301 24" 24' 0.82% 7-336A 724.80' 722.80' 7-335 18" 115' 1.74% 7-336B 727.00' 725.00' 7-336A 18" 103' 1.95% 7-337 728.30' 727.20' 7-336B 15" 105' 1.04% 7-338 730.00' 728.50' 7-337 15" 157' 0.96% 7-339 731.80' 730.20' 7-338 15" 140' 1.14% 7-340A 733.50' 732.00' 7-339 15" 155' 0.97% 7-340B 734.40' 733.70' 7-340A 15" 114' 0.61 % 7-340C 735.52' 734.60' 7-340B 15" 153' 0.60% 7-401 7-402 SEE SHEET 2L-11 FOR 7-500 AND 7-501 INFORMATION 9-200 FES- 310.03 9-201 Cl- 840.02 734.93' 8.93' 9-202 Cl- 840.02 734.93' 3.93' 9-300 FES- 310.03 9-301 FES- 310.03 EXISTING CRANE CREEK - TOTAL SURFACE WATER AREA FOR SITE 1.5 AC C°A R°O� s s i o.o * ° C-650 0 _ ao 00 _ .P R ° P°°°° gSSCC I PAS �� Y\ CA R0<'''i��% ��- SEALo <° 030523o master planning . civil engineering d r urban design . landscape architecture 919 berryNll rd. ste 101 . charlotte, nc 28208 • • • design 704.332.1204 . wwwAlor.design REMARKS RCP RCP RCP RCP RCP RCP RCP RCP RCP RCP RCP RCP RCP RCP RCP RCP RCP RCP RCP RCP, O-RING RCP, O-RING RCP, O-RING RCP RCP RCP RCP RCP RCP 8-103B I 742.80' 1 741.50' 1 8-103A 1 18" 737.05' SEE SHEET 2L-11 FOR 8-300 AND 8-301 INFORMATION I / O / / '\�i PROPOSED 1 1hAIT nC GRADING & STORM DRAINAGE PLAN ,... , . , ..�.., � , .".......... LEGEND PROPERTY LINE 86' 0.57% ALM - - ADJACENT PROPERTY LINE EXISTING 2' CONTOUR 86' 0.57% ALM (700) EXISTING 10' CONTOUR 86' 0.58% ALM 700 PROPOSED CONTOUR 98' 2.54% RCP, O-RING - - PROPOSED RIGHT OF WAY 100 YR. FLOODLINE 90, 1.67% RCP (based on 2009 FEMA maps) LPE=735.3 LOT PAD ELEVATION 58' 1.04% RCP for gravity sewer service) 177' 0.73% RCP MPE=731.2 MIN. PAD ELEVATION (BFE + 2') EXISTING STREAM 45' 6.38% RCP PROPOSED LOT NUMBER 24' 0.82% RCP LIMITS OF DISTURBANCE 25' 0.82% RCP STORM DRAINAGE EASEMENT 104' 0.60% RCP, O-RING PROPOSED SANITARY SEWER EASEMENT 116' 0.60% RCP, O-RING PROPOSED WATER 78' 0.60% RCP, O-RING MAIN EASEMENT 78' 0.60% RCP, O-RING EXISTING WETLANDS 57' 0.60% RCP, O-RING Ir' PROPOSED FLOW DIRECTION 82' 0.60% RCP O-RING PROPOSED STORM DRAINAGE 120' 0.60% RCP PROPOSED FLARED END SECTION 38' 1.17% RCP STORM DRAINAGE PIPE PROPOSED DRAINAGE STRUCTURE 24' 0.61 % RCP FUTURE I 12.5' ALLOCATION 50.0 1I PATIO 5' WIDE x 20' SIDEWALK 5.0'J T 13.0'-f PROPOSED BUA FOR ALL LOTS VILLAGE AT GRANITE - PHASE 2 CLIENT /OWNER: LGI HOMES CONTACT: JEFF WEBB 3037 GRANITE QUARRY NORTH CAROLINA LANCASTER, SOU DRIVE � LANCASTER, SOUTH CAROLINA 29720 300 LGI / HOMES SOUTHEAST (844) 566 jeff.webb@Igihgihomes.com r>Q , 1 °�..1 BMP SDE 1 ;I \ I EXISTING\STORM\ ATER BMP #2 DRYETENltiION OidD / SAND FILTER \ N_ CO O N w Q co O ti O CV N U Q Scale: 1"=50' -o Sheet Number x x 0 O 2L-5 a A B. EARNHARDT 1169-436 D 405 007 FFi / 730 0 - , \ \ // &STREAM )NE RA �/ / % GE.� PTi SETBACK _ 30 NJ L_ i - PROPOSED CLASS II RIPRAP EX. WETLAND �� \ •\ � - - - - - - / / \ \/ \�` - 1 xpp / \ \ \ - - - - - - \ \ � \ \ ST RM AT R 15 0 :•'•� LPE 732.9' O \ ,� E=728..' \\ \ / / ��0 \ . . . . . \ \ DRY ETENlI N OWN / / / / � �\ _.�-- -----67 COS ----- \ 249/ \ O \ MPE=724.- �/ - X. �FE I LANE) - - - - / / / LPE�734.5' - oL `�' LPE=7 \ \ \ . . . . - \ \ PROPOSED GRASSED k / = C ti A TO REMAIN � M15E 728.0�• - � � \ \ \ `� \ � \ _ _ _ _ � \ \ \ � \ BRIDGE ACCESS / , � PROPOSED UNDISTURBED / i Doti / X / O \ CLASS II RIPRAP \ \ \ _ _ _ _ - - \ LPE- - \\\ �� / �48 / O \ \ 168 \ �� o° MPE - - - - - --- - - / \LPE=7 . ' -' � \ 1�06 Ir?O \ \ / v v v \ V PROPOSED GRASSED\ / 12 \ BRIDGE ACCESS LPE=7 4.8' �� \ / LPE=735.2' LPE=735 PE=728.0' 1,ti m X 170 0 165 736 A\\A \ / p A \ \ _ PROPOSED BRIDGE BY OTHERS. o \ \ LPE=7 7.4' \ ... � �. co E=736.� I o, . AMPE=72 9 CC�S � ( OO� / LPE�737.9' \LPE=73§�2'i \ '�"' ° \ � so `5 ;- j SEE PLANS BY KCI.:•;•.•�• •�•; •, � ` ' ' \ ' / �Q' \/ / / 1� / / SOB � noo' �� ��p0 oS+ \ �O �i�i A � o � � A � ..•. \� � � \ � � l \ �� 73a `� I � - / i � I PE=737.5' � \ ARPE-726.0' � .-..... . � ....... / \ MPE�728.0' 1 0' SDE (PUBLI a - 171 1.000' r `LPE=747. 244// LP38.8' � � 190 �' � � / � \ \ \ / \ MPI 726�0' \ \ \\ • I \ \ \ � II MP/E=728. / " 1�ti \ � � � � \ 17 I 43 v / / / \ �� A LPE=75o. / ao O / \ 127 ' �' - PROPOSED GRASSED ... P BRIDGE ACCESS \ / /LPE=7 .4' 1 / / \ �> \ E �28.9' ;�. / �/ / �tk O Ig1 5 �\\ V A \ 2 V A I�fPE=72 .. \ \ I O 1 �• \ _ - . . . (/ V � � / / / � � � / / / � / � �' LPE-739. / � 1 i \ \ \ X \ - \ \ N \ \ \ / + 1 APE=74�.3' \ 7 / / \ cP \ \ \ L E�`/39.8' / ,.• /o \ �yo LPE=752.9' I I I . y L 747.1� - - N E FOLLOWS / P =728.9' / E-741.1' - I I I _ `\ s - \\ 1 / CRANE CREEK / ---_ I / "40_,189 LP / 2 s _- /740.2� l E (PRIVATE !� �` ^ 1$8 - / m \ \ \ 'x n \ ` \ . \ \ \ =728. ' 33/ p / I 3� PROPOSED / / \ \ \ ' �� \ \ \ \ \ \ . . . . . . . 1 �\ \, \ �1� \ �i I \ 755.3' I DITCH B �s. \ \ V LPE742.8' �� PROPOSED i \ �\ \ I �c� - - N _ 159 �50� o /` ,p \ L = 1' \ \ / \ CLASS II RIPRAP LPE- 2 � \ M � 7 \ � \ \ \ � �� \ / V v v A Cl) I A I / / - - I - / / PE=752.6' / 50. A V� C / 131 A - LPE=742.8' �� .V. / I A \\ EXISTING \ \I / I \ I I I \ I I I ��< N ` / \ \ I � 1 � � o � � � \ MPE=728\.9' - � � / \ � \ � 9 \ � � -\ - --TE�PbR R � CHM / UNNAMED TRIBUTARY \ I\ \\ \�\ \ 0 I \ , \ I I I N \ \ / �`� N I \ N ,� � 17 � / c� �\ \ y / \ V � V / A � � TOP OF REBAR TOTAL SURFACE WATER \ \ / \ o \ \ ^ 1\ 0 15 - - - I I / �s / \ O \ / li 2 0 I - - N=678,447.5543' \ \ AREA FOR SITE 0.4 AC \ A A �V A A LI E=75s / 158 \ \ \ \ 13 LPE=744.6' 743 I / 144 \ _ y�oQ - E1,562,904.6635' \ \ \ ��� A � � LPE 7�2.T E=72\9.2' \ o \ - ELEV743.98 34 � \ _- 1 / 6 / � 7 329 � \ \ / \ I 1�47 - / \ \ o -\ NAVD 88 - 003 \ 0 PROPOSED � / � �) A \ \ \ V / A � I � I � - PROPOSED / � � I I / :/, \=744.8' \ \ \ \ a2 \ CLASS II RIPRAP \ / �s \ \ -\ \ fi \ \ DITCH B /=759.1' \ I I I • �� LPE=75 .4' \ \ \ \ \ 0 / \ w - - - - \ \ \ 117 1 V v\ 289 I V I 196 - - - 1 LP O`"`��V� \\ Al cJ�G °geoo 0 / - - P� \•\ / � °oe°°° Z� \ � I I \ � o / I - - PE 61.4' � M � / 1 � � � •\ 2�8 I I i 1 N 197 - \ \ 1 - - - \ / \ \ \ \ \\LPE=�4 .1' \� \` - - - - - - A \ MPE=729.4'\ i LPE�745.2 5 00 � � ,- � I PROPOSED s \ E�74 _ I I a MPE�729.6 A � 1 I I I LP-756.5'- � � \ I I I I � � \ \ � -\ I, � o I � � � IN i � �/ / � - � \ 1 � �/ ' � LPE=757 � \ \ 13 \ \•A \ PROPO - -► \ \ � L E=744. ' �� o � \ \ ` - - - - - �� DITCH B JI \ 1- 2 7 i 1 I 19i3 ( I \ o I \ �� - - \ \ \ - PROPOSED 742.5' _ 'i i I LPE 747 2 -- 7 / \ ' \ 'I 1 � � � CLASS II RIPRAP � \. 1 1\ \ \ V 1 �- j o „ I `��- \ \ \ 55 / 150 \ \ �\ 0 ' \ I \ . . . . - . - \ �1'1 \ILPE=759. \ '^1 . . . . . 73 \ � � -\ 1. 1 $361 I I I o II 1�g \� 8=7s11.2 � \ 8 \ 17 / � �� \ - - - - - °° I I I \ \ I I \ 9 I \ \ I I \ ' PROPOSED , A , / � 1 V ro ao � 3+-p0 I LPE=74�6.6 �\ 1 _ � \ � - / _ �3a 8 , ♦ M E=7I13. �/ _�. LPE= 8.5' I O i� \ 15LF WEIR o / / 743. �ti LP=74 .6' \ \ �- ch I r Q 8 0.8 I I , CO / O / \ LPE= 42.4'� 139� WITH - - - Zo r a / \ I C \ ��` � � 7 6 3.3 I \ \ 756./ 8. ' \ \ \ ♦ NORTH 43?LPE I I \ I \ \ I I - AMERICAN i LPE=760.3' � PRv `�, MPE 72 . N �� I I I A 75s 1 zo's°E �� - _ GREEN - - - / -� ` H I I I 200 \ I 1 I I / / -' =- \ \ 1 o I - _ - m PROPOSED I I - I I \ L - 5' LP 1' 0 ��-� - SC250 - - - - - 5° \ \ \ 0 1 ID I LPE=7461' I \PR\ pcEl I / / \ \� ' MATTING / \ o O I 15LF WEIR I =74 . ' 1 I I \ I \ / / \ LPE=761.2' \ \ \ LPE=739.5' M V A / / �p L�E=744' A WITH -r �� I N / �' \ '\\ /o I I 1 MPE=736.2' r . . . . . . . . . 0 \ I \ NORTH I I I \ 152 \ 1 E=741 cA I j \ \ \ 137 \ 2. � 2. AMERICAN 07 1 - o ti . �- \ / 2.0 \ GREEN 1 \ 1 I N \ _ _ / 22 ' SSE .PRIVY U*3 � _ \ \ 222 I �i \V A I / M A V O PE-746.5� O`� O� 10- 003 - O ® 740 00° X \ / MATTING r v E-�42.9'' 20 O o \ \ EX. PROPERTY LINE. 0-102 1 " - E\ 228 I /, A �, PROPOSED 1 O \ v � V A LF�E=744.9' 1 / PROPOSED DITCH B z V A I L \ OVERLAND /� 2 3 j� v l rn� LEGEND V vv A \ I v V 11 \ \ \ 2 00 I o�A \ RELIEF PATH I ' 1 \ AA PROPERTY LINE \ \ I I 1 owCO ADJACENT PROPERTY LINE \ I I \ \ - 297Aq \ 1 \ \ \ \ 203 I s -�48 1 \ - - - - - - - EXISTING 2' CONTOUR 7 PE=745. \ \ \ \ �I \ \ \ y \ LP 753.T Ccr� 23� \�� $04 0 �7GG)--- EXISTING 10' CONTOUR PROPOSED CONTOUR DRO H SED V \� / %PE=743. ' \ ) ss° \ 8 \ - - PROPOSED RIGHT OF WAY - i \ \\ �� 100 YR. FLOODLINE ARDT (based on 2009 FEMA maps) . LOT PAD ELEVATION 217 00 2V 219 220 �� � 1" I � >> 1 6 �0�\ V O \ � ' � for gravity sewer service) / LPE=764.9� \ A , A 23(� I 31 I 74a v \ \ o MPE=731.2 MIN. PAD ELEVATION / \ L�E=760.� LPLs=757.2' BFE + 2 LPE=752.6' 1 v � I I \ J 2 \� ' m o LPE=746.2' LI E= 43.1f \ ( ) STR CTUFROM TYPE STDDO#T RIM DEPTH 10-100 FES 310.03 10-101 MH 840.52 745.00' 7.50' 10-102 DI- 840.14 756.12' 6.12' 10-103 DI 840.14 759.00' 3.50' FROM INVERT INVERT TO PIPE LENGTH SLOPE REMARKS STRUCTURE UP DOWN STRUCTURE SIZE RCP 10-101 737.50' 731.50' 10-100 15" 187' 3.20% 10-102 750.00' 740.00' 10-101 15" 133' 7.54% RCP 10-103 755.50' 752.50' 10-102 15" 343' 0.88% RCP \ 8 I V I \ I -- _o \ V A\1 I \ 1 9 1 �.� �I .=.... V A / 2�\ EXISTING STREAM \ \ \ Jall \ 0 $ \ r>s �0 \ \ \ 69 PROPOSED LOT NUMBER GRADING CX STORM DRAINAGE NOTES: 14. NO SOIL DISTURBANCE OR COMPACTION, CONSTRUCTION MATERIALS, TRAFFIC, 2 TRENCHING, OR OTHER LAND DISTURBING ACTIVITY SHALL BE PERMITTED I LIMITS OF DISTURBANCE 1. SEE SHEET 2L-2 FOR SURVEY DATA INFORMATION. BEYOND LIMITS OF GRADING WITHOUT PRIOR APPROVAL FROM THE ADJACENT \ •O 2. REFER T THE SITE PLAN FOR RELATED NOTES. OW NER. 1 O S O O S O Jg83 7q�70, /X\/ \ 207 \ \ 20' SDE STORM DRAINAGE EASEMENT 3. ALL SPOT ELEVATIONS REFLECT FINISHED GRADES. 15. ALL CUT AND FILL SLOPES ARE TO BE 2:1 MAXIMUM GRADE, UNLESS OTHERWISE / h - - o \ - \ \ 8- 104 J o Q \ �4p \ \ ^ \ \ NOTED ON PLANS OR DETAILS. SEDIMENT BASIN EMBANKMENTS MAY BE SET AT eo N o cb co - -� _ -� �� tps p \ p Q P \ \ 4. ALL ELEVATIONS ARE IN REFERENCE TO THE BENCHMARK, AND THIS MUST BE 2:1 SLOPE. MAINTAIN MINIMUM 2% SLOPE ON ALL DITCH CENTERLINES, UNLESS / _ \ `� � � 2Q6 PROPOSED SANITARY SEWER EASEMENT VERIFIED BY THE GENERAL CONTRACTOR PRIOR TO GROUND BREAKING. a NOTED OTHERWISE. MINIMUM 2% SLOPE ON ALL SHEET FLOW, UNLESS NOTED n v 8-210 , \ 8-209 7 81 _ _ 5. THE CONTRACTOR SHALL IMMEDIATELY REPORT TO OWNER ANY DISCREPANCIES OTHERWISE. KEEP A MINIMUM OF 0.5% SLOPE ON ALL CURBS, UNLESS NOTED FOR CULVERT P A PROPOSED WATER MAIN EASEMENT FOUND BETWEEN ACTUAL OTHERWISE. ' SEE 9.3FIELD CONDITIONS AND CONSTRUCTION DOCUMENTS AND SHALL WAIT FOR SHEET 2L-2 � \ 16. THE DENUDED AREA LIMIT SHOWN ON THIS PLAN IS THE MAXIMUM AREA TO BE fin, \ _ _ _ _ _ INSTRUCTION PRIOR TO PROCEEDING. \ \ \ \ \ EXISTING WETLANDS CLEARED. CONTRACTOR SHALL VERIFY LOCATION OF ALL EXISTING UTILITIES IN THE FIELD 17. ALL PROPOSED GRADES SHOWN ARE FINISHED GRADES. 2.0 I 2 I _ _ /` s \ BEFORE BEGINNING CONSTRUCTION. 0 2. \ \ �' � 18. ALL FILLED BUILDING LOTS MUST BE PLACED IN MAXIMUM 1 FOOT LIFTS TO A \ \ 2' \ 2•0 \ 2.O 2 6. CONTRACTOR SHALL BLEND NEW EARTHWORK SMOOTHLY TO TRANSITION BACK MINIMUM 95% COMPACTION. NC STATE BUILDING CODE STANDARDS FOR 2,000 PSF , 2.0 I ;\ ,1 0 1 I `��' / - \ �- f PROPOSED FLOW DIRECTION TO EXISTING GRADE. 9 MINIMUM COMPACTION IS REQUIRED IN BUILDING AREA. LL-;-\-;- I I I \ -... 7. LIMITS OF CLEARING SHOWN ON GRADING PLAN ARE BASED UPON THE 19. THE PURPOSE OF THE STORM DRAINAGE EASEMENT (SIDE) IS TO PROVIDE STORM , \ 1 \ \ \ \ \ I M m \ - � PR POSEQ \ I - - APPROXIMATE CUT AND FILL SLOPE LIMITS, OR OTHER GRADING REQUIREMENTS. WATER CONVEYANCE AND ANY STRUCTURES AND/OR OBSTRUCTION TO PREVENT / I 215 I I i \ ^ \c \\ 1 0l I I I PROPOSED STORM DRAINAGE 8. THE PROPOSED CONTOURS SHOWN IN STREETS AND SIDEWALKS ARE FINISHED STORM WATER FLOW IS PROHIBITED. 216 21\4 213 212 I I I ( \ :� . \ \ \ �• j �� �0 ITCH B \ I I I I -�\ ELEVATIONS INCLUDING ASPHALT. REFER TO PAVEMENT CROSS SECTION DATA TO J 211 2� 0 \ 209 �: I\ \\ -� I PROPOSED FLARED END SECTION 20. THE CONTRACTOR SHALL PREVENT THE MIGRATION OF SEDIMENT FROM THE SITE ESTABLISH CORRECT SUBBASE OR AGGREGATE BASE COURSE ELEVATIONS TO BE AT ALL TIMES. 1I p = g P = 6 .:LL.\ \ COMPLETED UNDER THIS CONTRACT. Know what's below. 4 -7 '.`... ...'.`.• O � � � � �O I I PROPOSED DRAINAGE STRUCTURE 21. PERMANENT DITCHES AND STORM DRAINAGE PIPES SHALL BE MAINTAINED BY THE z r / S I 9. CONTRACTOR SHALL INSURE POSITIVE DRAINAGE SO THAT RUNOFF WILL DRAIN TOWN OF GRANITE QUARRY IN THE PUBLIC STORM DRAINAGE EASEMENTS AND ® _ i NN,_ 1 ; ;,;`:,LL �LL `LLLL``; w / \ I I BY GRAVITY FLOW ACROSS NEW PAVEMENT AREAS TO NEW OR EXISTING SHALL BE MAINTAINED BY THE HOME OWNERS ASSOCIATION IN THE PRIVATE Call bdore you dig. 8-212 I I / Q - I \ DRAINAGE INLETS OR SHEET OVERLAND. STORM DRAINAGE EASEMENTS. SEE PLAN SHEETS 2L-5 & 2L-6 FOR DESIGNATION 8-21 1 I EX. W TLA� / / _ I \ 10. PROVIDE MINIMUM 2 FEET COVER PLUS THICKNESS OF PIPE OVER STORM OF STORM DRAINAGE EASEMENTS. / o I I \ TOR ` IN DRAINAGE PIPE IN PAVED AREAS AND 18 INCHES COVER IN GRASSED AREAS. 22. FINISHED GRADES IN THE STORM DRAINAGE EASEMENTS SHALL NOT EXCEED A C / I W \ I I \UND URBIE / / / / / _ \ ` 11. PIPE INVERT ELEVATIONS HAVE PRECEDENCE OVER SLOPES. HOWEVER, SLOPES 15% LONGITUDINAL SLOPE OR A 5% CROSS SLOPE TO PROVIDE VIABLE ACCESS O 50 100 .ZOO \ PRO O I n 1\ I I _ / / _ _ - - SHALL NOT BE DECREASED FROM THOSE SHOWN ON PLAN WITHOUT PRIOR FOR VEHICULAR MAINTENANCE. EX. PROPERTY LINE \ \ U, APPROVAL FROM DPR ASSOCIATES. 23. ALL FILL PLACED IN WETLANDS SHALL BE SUPERVISED BY A GEOTECHNICAL DITCH B 12. ALL STORM DRAINAGE PIPE TO BE CLASS 3 REINFORCED CONCRETE UNLESS ENGINEER. SOIL UNDERCUT AND REPLACEMENT (INCLUDING USE OF OTHERWISE NOTED. PIPE LENGTHS INDICATED ON PLAN ARE APPROXIMATE ONLY. STABALIZATION MATERIALS) MAY BE REQUIRED. 13. FES INVERTS ARE TO BE SET AT OR SLIGHTLY BELOW EXISTING GRADE. VERIFY ELEVATIONS IN FIELD PRIOR TO LAYING PIPE. Project Manager HVN Drawn By RJ/LG Checked By HVN Date 8/22/2019 Project Number 17031 REVISIONS: No. Date (M/D/Y) By Description 1 3-11-2020 RT PER TOWN'S AND NCDENR'S WQ FIRST REVIEW COMMENTS 2 6-12-2020 RT REVISION DOES NOT EFFECT THIS SHEET 3 2-19-2021 RT PER TOWN'S SECOND AND NCDENR'S WQ THIRD REVIEW COMMENTS 4 5-7-2021 RT REVISION DOES NOT EFFECT THIS SHEET 5 2-4-2022 RT/TC PER TOWN'S THIRD REVIEW COMMENTS C°AR°o</''''� s so * ° C-650 o °°° 0 R P°° ...... °° ''''�� gSSoc I PAS ���\\\ \\\������`� CA R0�''''''�� ��- SEALo <° 030523 NGU 2 master planning . civil engineering urban design . landscape architecture 919 berryhill rd. ste 101 . charlotte, nc 28208 design 704.332.1204 . www.d pr.desig n GRADING &STORM DRAINAGE PLAN VILLAGE AT GRANITE - PHASE 2 CLIENT /OWNER: LGI HOMES CONTACT: JEFF WEBB 3037 GRANITE QUARRY NORTH CAROLINA LANCASTER, SOU DRIVE � LANCASTER, SOUTH CAROLINA 29720 -4300 LGI / HOMES SOUTHEAST jeff. 566 eff.webb@Igihgihomes.com co N BUJ v! Q 2 I..L UJ z NQN LLr- V Q rW V J J i� 0 U) 06 z 0 N a_ M 0 U) I- W LULU 1 C0 0 U N N C6 L (>3 1= (>3 m c C6 4) i� cv M O ti O N N U Q Scale: 1"=50' 0 Sheet Number x x 0 0 2L-6 a