Loading...
HomeMy WebLinkAboutSW6140503_APPROVED PLANS_20140530STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT. NO. DOC TYPE ❑ CURRENT PERMIT APPROVED PLANS ❑ HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE o�DS YYYYMMDD LEGEND EXISTING DENOTES REBAR OR BREAK IN LINE O CONCRETE MONUMENT ❑ WATER METER GATE VALVE WATER LINE FIRE HYDRANT SANITARY SEWER MANHOLE SANITARY SEWER CLEAN OUT CATCH BASIN DROP INLET STORM DRAIN MANHOLE SITE NOTES 1. PROPERTY SUBJECT TO ALL EASEMENTS, RIGHTS -OF -WAY AND RESTRICTIVE COVENANTS OF RECORD. TAX PINS: 2. UNLESS NOTED OTHERWISE, THERE WERE NO U.S.G.S., N.C.G.S. OR OTHER GOVERNMENTALLY RECOGNIZED HORIZONTAL CONTROL MONUMENTATION FOUND WITHIN 2,000 FEET OF THIS SUBJECT PROPERTY. UTILITY NOTES x —FX. W— IX O NOTE — ALL PROPERTY CORNERS UNLESS OTHERWISE NOTED. 1. OCCUPATIONAL SAFETY & HEALTH ADMINISTRATION REGULATIONS (OSHA): CONTRACTOR SHALL ENSURE ALL CONSTRUCTION AND EXCAVATION ACTIVITIES PROCEED ACCORDING TO THE LATEST OSHA GUIDELINES. 2. UTILITY LOCATIONS: A. NOT ALL EXISTING UTILITIES ARE SHOWN ON THE PLAN. THE CONTRACTOR IS RESPONSIBLE FOR LOCATION OF ALL EXISTING UNDERGROUND UTILITIES. CALL NC ONE CALL (PHONE 811) 48 HOURS PRIOR TO EXCAVATION. B. COORDINATE WITH UTILITY OWNERS FOR LOCATION OF EXISTING UTILITIES AND WORK WITH THEM TO REMOVE CONFLICTS. C. VERIFY LOCATION AND ELEVATION OF EXISTING UTILITIES BEFORE CONSTRUCTION BEGINS AND COORDINATE WITH THE ENGINEER FOR CHANGES TO THE SEWER LINE LOCATION AND, OR UTILITIES. IF CHANGES ARE NEEDED, PLANS MUST BE APPROVED BY THE APPROPRIATE AGENCY. D. LOCATION AND ELEVATION OF EXISTING UTILITIES AS SHOWN ON THE PLANS ARE APPROXIMATE. 3. ALL MATERIALS FURNISHED AND WORK PERFORMED SHALL BE IN CONFORMANCE WITH THE CITY OF FAYETTEVILLE AND/OR PUBLIC WORKS COMMISSION. 4. ALL WATER AND SEWER MAINS, LATERALS AND APPURTENANCES SHALL BE TESTED IN ACCORDANCE WITH PWC TECHNICAL SPECIFICATIONS. 5. ALL DUCTILE IRON PIPE, INSANITARY SEWER SERVICE, SHALL HAVE GRIFFIN PIPE 'SEWPER" COAT OR PROTECT0401 LINING. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR RELOCATION OF EXISTING UTILITIES IF REQUIRED DURING INSTALLATION OF NEW WORK.\ ABBREVIATIONS HP = HIGH POINT ADA = AMERICAN WITH DISABILITIES ACT CB = CATCH BASIN CL = CENTER LINE DI = DROP INLET DIP = DUCTILE IRON PIPE EIP = EXISTING IRON PIPE ER = EXISTING REBAR EX = EXISTING FEMA = FEDERAL EMERGENCY MANAGEMENT AGENCY FES = FLARED END SECTION FFE = FINISHED FLOOR ELEVATION FH = FIRE HYDRANT GB = GRADE BREAK INV = INVERT ELEVATION JB = JUNCTION BOX LF = LINEAR FEET LP = LOW POINT MH = MANHOLE OSHA = OCCUPATIONAL SAFETY & HEALTH ADMINISTRATION PROP = PROPOSED PVC = POLYVINYL CHLORIDE RCP = REINFORCED CONCRETE PIPE RIW = RIGHT-OF-WAY SR = SET REBAR SS = SANITARY SEWER STA = STATION TBR = TO BE REMOVED PRELIMINARY DO NOT USE FOR CONSTRUCTION THIS DRAWING HAS NOT BEEN REVIEWED BY ANY GOVERNMENTAL AGENCY FOR COMPLIANCE WITH ANY APPI IRARI F I ANTI nFVF1 (IPMFNT r)R nTHFR INDEX COVER SHEET C00 SITE PLAN C01 UTILITY LAYOUT CO2 & CO2A GRADING & DRAINAGE PLAN CO3 & CO3A EROSION CONTROL AND SEDIMENTATION C04 & C(J4A PROFILE SHEET C05 PROFILE SHEET C06 PROFILE SHEET C07 PROFILE SHEET C08 PROFILE SHEET C09 PROFILE SHEET C10 PROFILE SHEET C11 PROFILE SHEET C12 PROFILE SHEET C13 PROFILE SHEET C74 PROFILE STORM C15 STORMWATER MANAGEMENT DETAILS — BMP-1 C16JJ STORMWATER MANAGEMENT DETAILS — BMP-2 C17 STORMWATER MANAGEMENT DETAILS — BMP-3 C18 DETAIL SHEET —GENERAL CONSTRUCTION C19 DETAIL SHEET —SEWER C20 DETAIL SHEET —WATER C21 DETAIL SHEET —EROSION CONTROL C22 LANE WIDENING AND STRIPING PLAN C23 � u n r io gents is arc u � h �rz lin. oqlik� Y i It, v r i i .signer with th-r i< i 1r1I ith the ,.rNAr J VS '�13 L�; 1 r4� � ,i �t ,te• o:,�ar Know what's below. Call before you dig. z , h Lo 0LO o� o00o us N (D } j 0 c? C w . y � p, 000 C) 0 yy O u-C? ;a rc°5 �t0U0 1,0 ZcCq Zits he Lr) C) 00q. J O z oC 00 E" J u- 63 0 C) 0 co T U S3S2 w.J �M a0_Z *zzll SEAL _ 53� , y /''ON AN p `; THIS DRAWING IS PRELIMINARY, AND NOT FOR CONSTRUCTION, RECORDING PURPOSES OR IMPLEMENTATION. c 0 .N v m 0 0 0 z Owner: CBMMPROPERTIES LLC CONTACT.- 238 N. MCPHERSON CHURCH RD FAYETTETIMLE, NC28303 PHONE:910-864-1125 FAX..910-8644938 Project: THE ESTATES OF GEORGETOWN PHASE 1 0405-42-0744 tax id #: 0405-52-1954 0405-51-2958 township: Rockfish county: Crr bala,rd state: NC COVER SHEET CONSTRUCTION DOCUMENTS job no.: P12-096 date: 12/02/ 13 drawn by: PDM survey by: JTR checked by: JAN sheet no.: coo s, GRAPHIC SCALE 70 0 100 200 4D0 SC ( IN FEET ) 1 inch = 200 it. LEGEND EXISTING PROPOS �Ifl` DENOTES REBAR OR BREAK IN LINE \ \ �% i s CONCRETE MONUMENT ❑ \ /'�\ �_ f� \� -I. II °�a AflS i jq2 �1 WATER METER / / \ PG9;Nz GATE VALVE x���6/ fl`�6 Iir�' — _ E.TIRA WATER LINE —Ex. W— / / -- \`\ aRvz cwsx /2•(0.1aG)_------ \]3\ FIRE HYDRANT \ SANITARY SEWER MANHOLE SANITARY SEWER CLEAN OUT °��t�� PL MU NG CATCH BASINJ' DROP INLET ❑ ❑ m o L / J STORM DRAIN MANHOLE �D� n N�(/ p NN 010 °°`"S /� v/ ! oascsfl-- OR 1/2 (O.b BC \ 1 \ \ \ IIPF NVL IN C ]80 11 11E_ J h V OWS-].-09e1 , 1�2 1 ( WMRERLANO CWNA / i A BOARD CN . P. ,7 0 I / 11liP61514 NOTE — ALL PROPERTY CORNERS � � "Z v UNLESS OTHERWISE NOTED. �� �� nN ],-R 5 RLAND CUR �// �I ° I) WETLANDS i Pa 0 THIS A —,PRREA y� T EV UATED 01 1\ 1 k'k i1 441 134 � I6! 2 J L ( wf I -na 100 3 _ �: �� _ \\ y Ex a ss x PROP 1 \ „ POND A y ] j� nn lle 1 i /� J m -- — — — <-- --I P j/IRCHCRE H GN 0 I I a p \ _ Oo \ y1 O R]3 2 aINCNCREE) sECnoN 4 I—v _1— I __�I--____" _sec ��-\} m � yA / -- — — — — my Wd11J p HCREw sEcnM nmx 5] z1e \ p 1 lel wdeEE s[cnav PxsEz I �50 ID tb ye 1 �n C9 1 B• � _. ]N 21 I i •91 96" R b H / IV ss I') PON AR A I I I\ 1 zez MR 1/2• a � � I � I � as � ze1 PROP BM 3 / �I II I I 11 z ' 1 1 1 zm — zi3 I ��� I A A A \ ss aw W 5 Y / ,b �J �z(— ) i - V i AXIPXPSRO 1 — )6E la`�z LENE I e] „ 1 J I nUxL R RIW 1 i 14 1 zn 31, SHARR. WNo.\OLI � ]lo CAR OR 8 R. ARMS n 1 ee14. PC t 31 im 1,0 1 l M s A — I % _ o t50 ,51 N I e 1� 511& Hasa C26 v t r ° 75 �N D I z_ // E% 59M11 \ / 150 _ i � TOP 1P4 IN POND AREA �.� -- ,iiii[TTTTaqqqq , _ / P AL ONLY W G IS NO C RTIFIED SURVEY AND -- \ N 11 CE MAY E P CED IN ITS ACCURACY. RIWING �QT BEEN REVIEI�VFn OV RNMENTAL AGENY bkCbMPLIANCE WITH ANY APPLICABLE LAND DEVELOPMENT OR OTHER Know what s elOwr. b CONSTRUCTION REGULATIONS. EXISTING INFORMATION IS BASED C11I before you dig. ON CUMBERLAND COUNTY G.I.S. DATA. a z z z 0 W 0 z W rc w Z rc W W z z z W N J O Colo) } j i7 v .0 oo00 ,0,� 0 C? Q vE oi{ ^ p Oo a^0 Z "T Q � q a5 PI�_ �C w •— X O CY m� Ma ` J a1 ii a p v1 �°=U c ILo_Z �M THIS DRAWING IS PRELIMINARY, AND NOT FOR CONSTRUCTION, RECORDING PURPOSES OR IMPLEMENTATION. C O M m m 0 0 O Z Owner: CBMM PROPERTIES LLC CONTACT 238 N. McPHERSON CHURCHRD FAYETrEWLLE, NC 28303 PHONE:910-864-1125 FAX •910-864-0938 Project: THE ESTATES OF GEORGETOWN PHASE 1 0405-42-0744 tax id 0405-52-1954 0405-51-2958 township: RockBsb county: Cumberland state: NC I SITE PLAN CONSTRUCTION DOCUMENTS job no.: P12-096 date: 12/02/ 13 drawn by: PDM survey by: JTR checked by: JAN sheet no.: C01 Q-� , N v) N O LX) O � O N 5 O00 N .� O O U aCC) °M a NU Qd{ U O N O O M �^ C1 = cc)Z < N M 0 �_ M U c Y - 00 J C3 2 X p > 'g Y co C O L J G `a o coo a M Ul-) a. Z C ....,,,., 03145� m pj-jy� yr No," i nu„a�e��•`• THIS DRAWING IS PRELIMINARY, AND NOT FOR CONSTRUCTION, RECORDING PURPOSES OR IMPLEMENTATION. c 0 X j m d' N O O Z Owner: CBMM PROPERTIES LLC CONTACT.- 238 N. McPHERSON CHURCHRD FAYETTEVILLE, NC 28303 PHONE:910-864-1125 FAX.-910-864-0938 Project: THE ESTATES OF GEORGETOWN PHASE 1 0405-42-0744 tax Id #: 0405-52-1954 0405-51-2958 township: Rockfish county: Cumberland state: NC STORM LAYOUT CONSTRUCTION DOCUMENTS job no.: P12-096 date: 12/02/ 13 drawn by: PDM survey by: JTR checked by: JAN sheet no.: CO3 z z y p LO p CN 00 in N z j C a � .o 0 0 00 z H tYL�O E U a ,�o0S�° H a� CO U' — : - N = 00 C) Xre Y _w ca co O W Z Gi 4� SEAL c BE 03145c9� = N c .p"�nnnmra�oa O oc '/"�ppnun umPaoo`� THIS DRAWING IS PRELIMINARY, AND NOT FOR CONSTRUCTION, RECORDING PURPOSES OR IMPLEMENTATION. c 0 N m m 0 O O O Z Owner: CBMM PROPERTIES LLC CONTACT. 238 N McPHERSON CHURCHRD FAYETTEWLLE, NC M03 PHONE:910-864-1125 FAX.•910-864-0938 Project: THE ESTATES OF GEORGETOWN PHASE 1 0405-42-0744 tax Id #: 0405-512958 township: Rockfish county: Cumberland state: NC STORM LAYOUT CONSTRUCTION DOCUMENTS job no.: P12-096 date: 12/02/ 13 drawn by: PDM survey by: JTR checked by: JAN sheet no.: CO3 a 100 O 7 104 108 $ CIO P' 45 3� O L _ / R SC y2)(, _ — -r-- —4,/� Q / �o \ lP I 172 I� �m O .I JACCOB 82 90 108 107 s� 110 I SI E ; 46 / 174 - \ — W 81— � 11, --e-- L 4 O Ex 6" ss T- x 8' — �`�47 2 � )1 121 m 11�2 °a O LIMITS OF O 6 `� ,24 O O 120 119 „8 „7 1,6 115 1 ROCKFIS I °J > I \ qg \� O O O O _ H ROAD it i o i DIST�JRBANCE 8 �51 L T OF 42 �q, 80 LIMIT OF -wo-N ROAD I II I I I R NCE '\ — — — — — I �¢ _ _ \ TEMP. HARDWARE CLOTH AND GRAVEL aQ. 0 49 - -� /INLET PROTECTION -EACH CATCH BASIN chi I 52 ` 41 / ` EPILACE WAL TIH GUTTERBU DYNG GRADING T(OIRIEQUAL) O 222 Q M A �K ION 4 I I I \ Oo NLET PROTECTION PRODUCT AFTER 221 S VICINITY MAP E2 �I PAVING IS COMPLETE. THESE PRODUCTS — ` 223 — --/ i I I BIRCHCREE�y SECTION 4 ` 6 _� I mubi REMAIN IN PLACE UNTIL 227 22 2 2 0 PHASE2 QU CONTRIBUTING DRAINAGE AREAS ARE 2 NOT TO SCALE so 4. �' O STABILIZED. - -- I \ O 1 �. �20 GROUND STABILIZATION A * 8 --� pR I OBS CREEK CIRCLE -o €> e S5 ®— 40 SITE AREA STABILIZATION STABILIZATION TIME DESCRIPTION TIME FRAME FRAME EXCEPTIONS Perimeter dikes, swales, ditches 7 days None and slopes High Quality Water (HQW) 7 days None zone Slopes steeper If slopes are 10' or less in than 3:1 7 days length and are not steeper than 2:1, 14 days are allowed. Slopes 3:1 or 7 days for slopes greater flatter 14 days than 50 feet in length All other areas NONE ( except for with slopes flatter 14 days perimeters and HQW than 4:1 Zones OP OUT n .zs I BI CHCREEK SECTION 57 ON 4 I PHASE2 wV 175.a O 239 237 h __ — 0 � 39 ,0 AD 240 238 rn — 1a 125 IT OF O � 8 �%� 241 1 w �^ 3 1 � � 1 23 Plyq 6 � 127 Z� 58 o B l�U38 \ 11 1 88 ON PROP i 217 1 FENCE ' i 76 267 t2 / 2s4 129- � e0"� 60 < 36 \ 216 ' f42 265 286 11 O r / G O 3 �� rws REoui s� ` IC 6i A r� I -70 285 1 1 31 I 134 - 1 292 / PROP( E P PO b % I - * Extensions of time may be approved by the permitting authority based on _ _T FEN / 1,, - 1 zs8 263 e Weather or other site -specific conditions that make compliance impracticable.' BMP 3 LIMITS', Off- � � 7-33 (Section ILB (2)(b)) A A l DI'ST';Uf B N E. 133 24 so 1 1 1 2s3 �i 15 1 1 282 1 O — 1 O O / � � TEMP. HARD ARE CL TH AND GRAVEL U1 � Z 269 's REC i / I TwREA E(� IRE INLET PROTECTION - EACH CATCH BASIN siuzn Q 32 1 9 0 oA4^,1 fi5 21 TYPICAL DURING GRADING ACTIVITIES. �� 1 = O s •AREPLACE WITH GUTTERBUDDY ORE UAL it D- 246 i N 1 I INLET PROTECTION PRODUCT AFTER 134 281 1_ 1 I I AVING IS COMPLETE. THESE PRODUCTS 135 S 1 I 1 �1 1 270 1 MUST REMAIN IN PLACE UNTIL I v, J CONTRIBUTING DRAINAGE AREAS ARE 31 T N / STABILIZED. O 12 1 �309 PR P S 66I r$ 247 Q 1 1 1 280IL F O 1 16 SE "S 1MM �� I / 7 EVEI . 1 17 �66 1 1 271 1 SKI ME IN BMP- FOR CE ADI 1 IOR ICE IAM ERI- ) 38 ' 30 \ x $ Ql = 62.16 CFS=0.50(6.04)12.53 `r / 1 R I D SURFACE AREA - 2 010 cf 3.2" ORFI E P V E / r� < /67 2J 311 s 48 1 RE RE )RAGE VOLUM 37,800 cf 3 D Y D AW 1 �' SDTEORPTR CG= EE1A4V.0O' A(3:P1 RSOIDVEIS�ID-ED29=87726 Sf pf \ 1 72 310 L1 1 EM RGEY -ILL A 141 pppppp�QQj I O 1 a . Width = 10' min. ` R LE GT 139 210 1 1 9 73 278 Y 1 SEED IL SHEET C18 & C71 POND a s I I 1 FEE OT REQUIRED DU SIZIREB FO^h ',?/ 1` I i I •� I I 143 ,1160 1 $ -� POND I 19 VOLU ROM SKIMMER TO TOP OF RI 1 1 "NO LL BERMS AND EM8 SHOUL E C PA TED T 95 COMPACTI ANDARD PROCTO ASTM 698 ST. I I 28 r Ty I �� \ 1 1 LL BE S AN BANKMENTS SHALL OVER WIT I I !9� _ $ 1 �, 0 1 2 1 1 1 MINIM 4" PSOIL AND SEE D MULC AS I I I I �i I 69� I 1 1 20 74 s 1 LIE �I 45 SE?NE s A \ 2 1 1 147 46`. 251 27s 1 O ( — — — _ I g / 14 COURT �� x 70� zo6 1 5 1 I I SAND z, 1 � i -174 53 � s �IU DICTIONA ) i�= — zs -- o i I sz I 6 I E I 207 1 `O > "' 20 14� $ 2 -172 1 1 2 3 LEGEND 53 25 zos 20 „� $ -- -o LOD LIMITS OF DISTURBANCE _--� I ti 51 ------- _- -- 206 7� 1 ■ SILT FENCE 171 S R N - -- ,.� , 7 TDy— +� TEMPORARY DIVERSION 1 — � 1 A _ C� 73 69 — EpgT �� 6 c� - C�E TYPICAL CONSTRUCTION ENTRANCE cfR —�— 1 --- A/�� 165 166 O O16 Q _ X i IIII TYPICAL BLOCK AND GRAVEL DRIVE 79 N 1 INLET PROTECTION 1\ 1 75 O O 1s2 - - m GRAPHIC SCALE �� �� �� I • 00 0 5o ap zoo ,�o NCEPT PLAN ON OND sED \\ \ \ \ \ THIS -DRAWING -IS NOT A CERTIFI VEY AND NO RELIANCE MAY BE PLACDINITSACCURACY. 1IS DRAWING HAS NOT EN REVIEWED BY ANY ( ]N FEET) \ GO NIL NCY FOR COMPLIANCE WITH 1 inch = 100 ft. — _ v� `� 50 ANY APPLICABLE LAND DEVELOPMENT OR OTHER—now W 8 S �W. GULATIONS. EXISTING INFORMATION ASED Ig. POND AREA `CUMBERLAND COUNTY .LS. DATA. -- _ �1 t1. z r N OLO NOMO� N z O Nr a V) `o a c � -a z V, _ _ — L C C S ^CIO }O Z M [ H d 2 Y LO �,� _ z z OCO O^i m u = O M p cn T 01 -- C w J � M O d IJ .s N I'ary/�'''' � = 031459 y THIS DRAWING IS PRELIMINARY, AND NOT FOR CONSTRUCTION, RECORDING PURPOSES OR IMPLEMENTATION. c 0 d rr 0 0 0 z Owner: CBMMPROPERTIESLLC CONTACT: 238 N. MCPHERSON CHURCHRD '.. FAYEYTEVILLE, NC28303 PHONE:910-864-1125 FAX..910-864-0938 Project: THE ESTATES OF GEORGETOWN PHASE 1 040542-0744 tax Id 0405-51-2958 township: Rockfish county: Cumberland state: NC EROSION CONTROL AND SEDIMENTATION PLAN CONSTRUCTION DOCUMENTS job no.: P12-096 date: 12/02/ 13 drawn by: PDM survey by: JTR checked by: JAN sheet no.: C04 F7SHeR 7 I I %�92 100 104 Q v v 1> C 108 s IL CA 45 yr R SC o N L - �-- - - -T- -L 4�� Q / 3° \ \ 1 Cb \ o ) 1 72 p m O co 99 105 V! N co 106 Q' z Z) O st �� 110 Z a N.- O SI E / / 46 / a \ W 174 OUZO 10 — — O O TO U ` -EX 8" SS -T-uX g"�� 047 '�y� E m <j O O 70 U 2 N \\ "� 43 123 122 121 120 W m .- O J O N O as t12 �� XOO� �Q LIMfTS OF s �' 124 O O 119 118 117 116 115 M N i �` O O O Z a oM'--� ROCKFISH ROAD I II W I D I S R B A N C E\ 48 \� 42 O I S' ru J D_ D d Z LIMIT OF , 3 EN ROAD � 8 �Ei Ld CAMD P. HARDWARE CLOTH AND GRAVEL w o . NI '�a ¢IN TYPICAL DURING GRADING ACTIVITIES NREPLACE HU WITH GUTTERBUDDY (OR EQUAL' 222 Q Y 'INLET PROTECTION PRODUCT AFTER 221 S emuu „ VICINITY MAP tK E2 TION 4 I i IsE2 PAVING IS COMPLETE. THESE PRODUCTS 223 0] I I I BIRCHCREEI� SECTION 4 ` 6 Q' 'MUST REMAIN INPLACE UNTIL PH 227 22 2 2 0 2 1 AA Q� CONTRIBUTING DRAINAGE AREAS ARE 2 NOT TO SCALE I 50 q�, O STABILIZED. 184 55 w n220 224 ---- l� i 1 6" O�� * - - A>'R 1 OBS CREEK CIRCLE GROUND STABILIZATION L>-D7-EX e SS ®— _ ao SITE AREA STABILIZATION STABILIZATION TIME DESCRIPTION TIME FRAME FRAME EXCEPTIONS Perimeter dikes, swales, ditches 7 days None and slopes High Quality Water (HQW) 7 days None zone Slopes steeper If slopes are 10' or less in than 3:1 7 days length and are not steeper than 2:1, 14 days are allowed. Slopes 3:1 or 7 days for slopes greater flatter 14 days than 50 feet in length All other areas NONE ( except for with slopes flatter 14 days perimeters and HQW than 4:1 Zones TOFx1a oz JI\\RANSC B ROA OUT 11 .za I BI CHCREEK SECTION 4 EOP lets \� 57 - / �/`� �v \ 2139 ryy, \ /i 50 " R ON 4 I PHASE2 iNv ns.a �Y 39 237 --- � : 10 � � s O � 240 239 238 125 ; � IT O F B 58 38 ENCE ,Cp`� �� 217 6 287 264 12 1 7 4r- 1 1 89 60 1 \ C216)_ 265 286 1 CO>Q 130 A 13 \ \ 11 35 I 1 i 292 P1 I ; 11 132 \ H 1 1 63\ PROP E , ! �- �'' P o I * "Extensions of time may be approved by the permitting authority based on _ _ T FEN Weather or other site -specific conditions that make compliance impracticable. ' — BMP A EA 3 r LI�I ISI 0� \ 33 214 so 1 1 (Section ll.B (2)(b)) '� � 1 � / B15S UkB�N E 13 61 Z 15 1 24 1 269 282 1 293 1 O R C TEMP. HARDWARE CL TH AND GRAVEL � 1 ZO � E i I THI�AREA Ell IRE 'r INLET PROTECTION - EACH CATCH BASIN 32 _ DA4'�ROU N r TYPICAL DURING GRADING ACTIVITIES. 65 D- 21 \ s'Aswu I REPLACE WITH GUTTERBUDDY ORE UAL i INLET PROTECTION PRODUCT AFTER �;134 I \ 246 �r1 281 1 I I AVING IS COMPLETE. THESE PRODUCTS 135 1 ^� I MUST REMAIN IN PLACE UNTIL270 CONTRIBUTING DRAINAGE AREAS ARE 1 3, T N '�5B g STABILIZED. II 66 e , 2 1 10 309 i r 247 x 1 280 1 O 1 / PR P 7 16 SE "S IMF IM 17 1 � (9 BMP- =�.6" 1 J30 � � 57 i OR ICE IAM ER - M 38 L Q 1 = 62.16 CFS =0.50 6.04)12.53 I `i , ) f I $ 1 REQ I D SURFACE A EA = 2KC40 Cf 3.2 ORFf E P V E / � i 47 $ r 67 ' 2" 311 6 4g 279 1 RE RE TORAGE VOLUM - 37,800 cf 3 D Y D AW N / 1 ) 1 1 - RE CE A A PROVIDE - 29,876 sf 3, 0 STOR GE VO IDED = 72,5cf DEPT = 14.0' (3:1 SIDE S SLOPES) �� ff 1 / 1 1 EM RGEyCYIL A r a t4 2g 1 I 2 1 1 bbQQ 1 a .Width = 7 1 mfn. ` IR LE GT I I 139 50 R 9 1 SEED IL SHEET C18 8 Cl 7 POND SIZI �� �`� a / � I .1 I I 6� � 210 1 � 278 Y FLE OT REQUIRED DU FOREB POND ^� 143 19 73 a 'VOLU ROM SKIMMER TO TOP OF RI ) I 1 1 1 1 "'NO LL BERMS AND EMB SHOUL E C PA TED / li II T 95 COMPACT' ANDARD PROCTO AST M 698 ST.o I I 28 OVr T 1 I LL BE S AN BANKMENTS SHALL ER WIT 1 A MINIM 4" PSOIL AND SEE D MULC AS li'I 1 I 6�°---- PE 20 74 s , � E 1 as N 1 � s 2 I 4s O pHA 27 1 147 - 1 - �� I 14 �` s 70 208 251 276 11 coy"1 / 1 5 J I B NK �21 o 174 N ! - - 26 o _ TEAM 210NA _ r 52 53 1 S — — — — , 6 —� r o 'T}� -- _ 207 1 1 `° .P N 20 / 0 -- --._ r o 1 15 $ 2 172 2 3 9.W o ■ �1 11 11 1 ��I N�� h 1 �o! \ \ 52 15 y ► --25LEGEND a I 0 1 205 20 )151 \ 2osLOD LIMITS OF DISTURBANCE W /°150 SILT FENCE a s r ' - v� IS R N Q TD* --�- TEMPORARY DIVERSION 1 A c� 73 - CCE o - � 69 b TYPICAL CONSTRUCTION ENTRANCE aR . 1 \\�� \� ��� �V A,� - - `� 165 - - �� s -�- - - - 14 1 1 163 1 TYPICAL BLOCK AND GRAVEL 79 rrn k j J Q INLET PROTECTION - - _7s \ 160 � � - �� — 74 75 - \ _ ---- 1162------ GRAPHIC z SCALE sED I oND0 100 0 50 100 200 400 NCEPT PLAN ON — ' 1 1 \ . — \ \ \ \ \ THIS DRAWING IS NOT A CERTIFI VEY AND < 1 \ NO RELIANCE MAY BE PLAC N ITS ACCURACY. ( IN FEET) — — \ �— IS DRAWING HAS NOT EN REVIEWED BY ANY 5 w — GO N�L NCY FOR COMPLIANCE WITH 1 inch = 100 ft. — �A 5C iIOW what 8 OW. U m 0 6 , ANY APPLICABLE LAND DEVELOPMENT OR OTHEW 1 ' --- Co GULATIONS. EXISTING INFORMATION ASED Ig. POND AREA ON CUMBERLAND COUNTY .I.S. DATA. -_---- Sru 9 9<' SEAL = 031459,Pq� Ern 5 "'annnm""" Q A "nrriuuua`"``` THIS DRAWING IS PRELIMINARY, AND NOT FOR CONSTRUCTION, RECORDING PURPOSES OR IMPLEMENTATION. c 0 m 0 0 6 Z Owner: CBMMPROPERTIES LLC CONTACT. 238 N MCPHERSON CHURCHRD FAYETTEVILLE, NCM03 PHONE:910-864-1125 FAX.-910-864-0938 - Project: THE ESTATES OF GEORGETOWN PHASE 1 I 0405-42-0744 tax Id #: 0405-52-1954 , 0405-51-2958 township: Rockfish county: Cmhffland State: NC EROSION CONTROL. AND SEDIMENTATION PLAN CONSTRUCTION DOCUMENTS job no.: P12-096 date: 12/02/ 13 drawn by: PDM survey by: JTR checked by: JAN 1 sheet no.: C04a d oM J _ co 03 J l II �S V FIREPROPOSE tr'�,000 HYDRAN f I \ \� S ASSEMBSTA V v -� I I I 3 CB-20 TA-1 +36.7 TOP 179.5 y \ I V / IN 176.2 Oe •! Sp �O A� �\ \\ k9�' 1 A C� A- c� \ \ V I A CB- 02 �In STA 11+9 .73 TOP 168. 6 ,�Z% 1g� 6 ,� �S �x 3 �7 I 0 \ � / I IN-1 5.23 205) I IN-1 3.97 203) 7 e_4 ,.1 \00 OUT 163. C -204 \ \\ l \\ CB-107\\\ % S A-14 .5 79 TOP- 79.55 INV- 76.30 \ STA-10+52,1Y------_J// \ s6 TOP-166.60 0-rC, / \ \ CB 02 \ \� PROPOSED INV-163.70_ / D\ 0 �� \\ i \ O \ \ �\ \ TA-9+39. 1 \ \� FIRE HYDRANT P-167.88 \ \ap SSEMBLY `J 5•`.0 ;3 \ \ \\ 1z 0 z \ \ I \ IN-16 7(109 \ \rs S TTA,9+69.08 IN-163.3 0 \ T6 CB- 05 L \ \ Y n \\ CB-104 PROPOSED STA-4+08.84 FIRE HYDRANT ASSEMBLY \ -162.60(1 \ \ OUT \\ \\ (� 2% _ STA- 1+91. TOP- 68.5 3 TOP-175.44 STA 4+66.6 -103 ST 7+56.07 __� Ok\'\ k INV-1 5.31 \ 4N-172.04(111) TOP- 73.35 1 0g6•-15"RCp 15„RCp / v IN-168.7B(105) \ OUT-168.53 IN-16 95110 - \ O \\ 167.94) PIER rrpp U CB-105 STA-2+68.75 M O 31%ro0+0---- OUT 674(4 CP 2.78% 8, D 1g R 20_F, TOP-172.64 181.4 INV-169.24 p0+ 0.25% 25.50 -15 CP _1 -108 CONTRACTOR TO VERIFY 350•-18"RCP d + -1 STA0-+-52r'fiY 1 \\ HORIZONTAL AND VERTICAL StLF 8 DI WATER -I -I 00 TOP -166.60 \ LOCATION OF EXISTING 16" MAIN BEFORE CONSTRUCTION WATER 033% R -1 ® 00+9 OO+L CB-109 INV-163.92 PROPOSED TAP LOCATION MAY CP /20�F 8 4650j ��2y,C CHANGE BASED ON CONFIRMATION 3•.15 -_ 140Icn 0.3 TOP-1167.881 OF EXISTING WATER MAIN \ \ INV-163.35 1 \ PROPOSED 16" vC D\ WP T6R X 8" TAPPING SLEEVE AND 2p�F 6 A- CB-110 STA-7+56.d7 \ -'�--�\ 1 8" GATE VALVE " C� OO CB-111 TOP-173.35 NV-170.10 STA 0-6.54t / ® 0• 32% o STA-4+08.64 / ! TOP-175.44 0� \ A-INV-172.19 CB-1 n ST I MP TOP-172.6 \ INV-169.39 - at �W., ------------- Cal bef r a y9ib dig. o _,- CONCEPTUAL L N NLY , RE L\\ M ARY THIS DRAWING IS NOT A (b ]FIE p SUR Y AND \ - NO RELIANCE MAY BE PLAS IN 1 S ACC RACY. / 0 25 50 100 �j■ WH I TE H A VE N DRIVE 5 0 � R /W GOVERNMENTAL AGENCY FOR COMPLIANCE WITH ANY APPLICABLE LAND DEVELOPMENT OR OTHER ( HORIZONTAL -IN FEET) 27'13 _ p REGULATIONS. EXISTING INFORMATION IS BASED CONSTRUCTION LJ ON CUMBERLAND COUNTY G.I.S. DATA. 1 inch =50 ft 10GR HIC SCALE �- STA 0+00-15+00 200 w - T T -- - - - _ -- o � jV�-� f fV = : 8 EL-Ei � 173.2 -- -- i K - 7.50ZE - - - - -K[GH O I�Al III_ _NT 7 .0 ' C V f 1 � 13+ m ¢� U b VA P TA __ 0 2s P LEA 1 3. 2 PVI E EV = 172 -- Pill ETV _ 179.67 - -- -� - - - - - _ ��- VI ELEV = 6 .80 v - - -j �- - - - A.D. 8 07 - ao A. + 3. D -K -6.07 _ �t 3fi I - - -' T -- - -K-= - - - iLLI Ti I I - ° v 1 5.0 NC --190.00 - vc --�- c m w 1 0 1s000loo" I I O v - -_ _-T _� _.__ - _ -_ - t - --- - - - _. _._- -_ - - J - M O O m y i . " + (V M U U lil I � W W r- I '.. m In 15- 10 - o g O f / 180 ___�__._--�.. III I RIP E - - - 'R , DE I . -- -_�- / 0 e 77 � WATER 1 - - -._, • I �___ -- ---._ --- 0 2 I - - -1 - ----- \ i- - ----- -I- - _�-___ I 1 no14U.. 1.1 R PO E ° - - PR P SE 8' VC C- 90 AT R II - AN TER_- - - ��' - --- - - ____-.It-- - _--- ---- - - ---- ---- - - - �_ ---.. - - - -- - - - _ t 5 32. T 0' DI -, --- -- -- -' : 150 i r ! WATER 16LIT- I -- - - - - - ( m- r I - - I Ii i m M I 002O I�- I, _ - .. -� m t �� -�_ - N W J ¢ _ m I --. ¢ a. . F N rL o Irmo m M x m _IL i-, -' _- -,__ •_- -__ I_ i-O. 0 �.. - _.- -__ - -_- Q -- - - ---I r _ O .�- to O 0 Q N 0- _ N N o a m - v - O v m + - ___I -- �.-_. ---- i T I 1. -- - ---- _ -- rnm NM } +ro O o Nm o c° a -_-.. _�_ -o'rr� l - - --- -- _ - __-.___ _ ---o _ 'ri -- -oE-mad-- _ a0 l m m N I I O DATUM ELEV m z z 'I a~ o z_ z m l z z m a vl m~ o jZ 150.00 IN IN00N mrrr N 10 NM O IN M E 00 Or a0 Mr 0 OM Lo0 Or d'0 mm 0 o Mm M 00 .0 10 M 00 OppN 0 rNrj vcrV Otrl)MMr Nrr 00, 66Il mr LON it IN to ro n N OO 1IM r 41 6O 6L6 6n rNr7 O 00 1pR nn rlr 1- r rr rr mr m r mm mm ID ord for r rr mm 1 00 2 00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00 13+00 14+00 15+00 a h O I O 00 "T a .0 00� tj a C3-00 N Q 11 E O t O O O O U Z N C O O ui 2).- J O Y 0 0 O cc C p cM+� M � UlfO o_ z SEAL 031459� e- y �FSiS�Q.� c` THIS DRAWING IS PRELIMINARY, AND NOT FOR CONSTRUCTION, RECORDING PURPOSES OR IMPLEMENTATION. c 0 .N m OC 0 0 0 z Owner: CBMM PROPERTIES LLC CONTACT: 238 N. McPHERSON CHURCHRD FAMTEVILLE, NC28303 PHONE: 910-864 1125 FAX.•910-864-0938 Project: THE ESTATES OF GEORGETOWN PHASE 1 0405-42-0744 tax id 0405-52-1954 1 0405-51-2958 n township: RockSsb ' county: Cumberland state: NC WHITEHAVEN DRIVE PAVING PROFILE SHEET CONSTRUCTION DOCUMENTS job no.: P12-096 date: 12/02/ 13 drawn by: PDM survey by: JTR checked by: JAN sheet no.: C05 II -.�-1- - - N, T o_ I - - - OHt - -- 2-OHt - - -2 J- / �0 N - 2--O ft - - - 'V S G� 2--OHt - \ \ 0 - /I _ R STRUCTURE - --- �^o - - - - 2-OHIIF 2-OHt---- 2 Z 5' SS (15) STA 21+ 6.95 SSMM 4 , / - - - OHt---S� -- J O - TOP 183.3 -------------- STA 2 .03 12 / • - - - - 2--01 - - - - OHt - INV IN 170. INV IN 168.6 ---- TOP 1 811 / --2-0 _ LJj = NV OUT 168.5 J 10 O INV IN 165.22 INV 0 T 165.12 SSMH 13 ( ) A 26+50. / \ D6�\ V �G 07P REPOYDRAN O Og o rn z it TOP1D INV OUT6 6 34/ti CB-342 o Z ASSEMBLY c } _ om /a�i*� el WTOP-185.33 " o INV-181.93 +I STA 21+94.450N N c� o -� -� M o a O N _, ti o+ / r y y o 7, 4 SSMH (16 O m STA 1 27.41 PROP SED 8" X 8" X 8" C OSS w W/ 8" GATE m ormn n N CB-3 l n n w o V� ^ OU fig. 4 ox M SSMH (18) 2 + 3 °� `� N w z m n m O a0 86.63 O o z m STA 21+36. _ n r _ + �, A NV-773.99 -178.02 �- _ - to v FIRE HYDRAN / / Co o STA 15+43.91 TOP 183. w o _ ¢ SSMH 17 m U ( ) m INV IN 173.16 T M m STA 0+1 o a INV OUT 173.0 � N w w o< w CB-347 -P + w o N N N ¢ wiI w z m `�' � ASSEMBLY CB-345 TOP-180.35 STA 26+62.98 S 4" t IN 177.76 OUT 177.11 STA TOP 187.87 ^ Q INV IN 175.46 PROPO�D��_ ^b g" X 8" TEE ��5 W / 8" GATE VALVE m m 7�` i n J B-341 ¢ - w o / a co-184.13 1 OP-167.89 Ins o + i O No CB- I P INV- 80.65 l\ N TOP-180.85 F° INV-177.45 pTR z1+93.os o 25.50 -15 RC INV-176.85 UQw �� ` 14 PROPOS GI / 8" PLUG W / ' O 0 INV OUT 175.36 17+07.77 STA 17+17.77= S ` to INV-184.49 O RCP N 2®� -13�� 2®0 -� PCR 20+ 5.90 GR 184.1 s 20L 8' I 24 00 20LF 8" ATE 25+ 2Q ~ O LF NO DI J W T ¢� 6+00 ER �� 4 4 n W = � BLOW OFF �(/ / O STA 26+46.97= / u 88 39% A - 23+00 -- w ti `b - `� o STA 0+10 +00 _ 20LF DI 00 F SDR-26 $S 1.00 m ^xo 187.87 ~ 20L DI WATER 2 +00 PRO S 335.0SLF NN o �6x O OS 164. L 8 17 �7.00� 1 00 1 +00 20LF 8 I WATER ROPOSED - D 21 6LF OF 8" S R-26 S - $$ 1.00% 85.V-1 21 .54LF, OF ,$" DR- NI +aess o+q v I II o CB-343 ^ TOP-17 2505039% p 15 b ^ pR pTR 1+00.87 GR 18 .34 �RR182 598. x �' LO N I I I '- INV-t75.4 .4 °' ^� 13.6 785.20 3 PCR 17+57.71 n CB-340 u' -+ o m n TOP-1 a orn � � rt GR ea.o3 CB-338 o TOP-184.05 o w z -+ INV-180.55 �II j �+� CB-337 IN - N TOP-180.85 - zm n c � INV-177.35 N -� N � w c0 r ro I "' `O I O w � I m I CB-336 TOP-1 IN-173.89 I OUT-173.16 m ¢ 337 ( ) ~ C8-344 TOP-180.35 8 ry �' + ^ INV-176.75 to ti SSMH (12) STA 28+58.97 TOP 182.17 �Sp IN 162.29 16 OR 188.50 rj INV-184.39 m z + LL1 N w (� O o> �/ o Q Ox INV OU rx o Lv PROPOSED AIR RELEASE VALVE n STA 17+75 c ,o io o �m O w o< m rn c� w �r-i + m in I z + z rr'" a < Q rn "ci lli ^' -� I 38 I II h j J w o �� `p o o 0 ? x 2 9 J \ w m w 4 n S < ►�j.I 40 39 I I 36 35 0� i.`r \ \ ~�Q 45 I i- g rn� 44 43 CB-339 TOP-185.33 WO oo INV-181.83 I (,) Q I 34 PROPOSED B F Op 3 8" 7NV O �� �� N I I 0 8" GATE VALVE Sp 0 \ R� 7 N O STA 27+88.97 Ln 7 (5 6 _ __ 56 z I - -�33 =� oon 11 37"00 EPSM2EN1 ' ' 57 ORp\NPGE '' oo PCB wl ,-' - ----------- ------ - ----3E _ f N -_-_-- ----- --__ - 18 2 UI �I O y z a.L I -----20' DA�.�ASM€N - �� : o I I NI I -- --- -- -- -_ 31 tK THIS DRAWING IS NOT A CERTIFIED SURVEY AND o u So tooto WHITEHAVEN DRIVE 501 R/W RELIANCE MAY N PLACED IN ITS ACCURACY. THIS DRAWING HAS NOT BEEN REVIEWED BY ANY THIS DO NOT USE FOR ' GOVERNMENTAL AGENCY FOR COMPLIANCE WITH ( HORIZONTAL -IN FEET) -� 2 7 B - B ANY APPLICABLE LAND DEVELOPMENT OR OTHER REGULATIONS. EXISTING INFORMATION IS BASED CONSTRUCTION N 1 inch =50 ft. w w STA 1 5+ 00- 30+ 00 ON CUMBERLAND COUNTY G.I.S. DATA. GRAPHIC SCALE 200 5 4 HIGH POINT ELEV = 188.55 200 i IG POINT TA-17 7 � I Sr 0 - o O K - = 3.53 - - _ _ _ LOW POINT ST _ 2W51.06 H G P IN S A _ 8+ 1. Cj M C L o J _ - P S 2 00 P S A 4 50 ; P 9 A28400 L_ Io rn EIEV - I �< �� r -VIE V, r = 7 .5 - _- '$TA o -- - -- - _ - - - = - - w w w - w w 1 0 - w o a 5©.0 VC o 11 .0 C 1100.10 C 1 0 _ - - - --_ - - N •- m N CIIi 00 - m W N W I ' �II. m m w w ,. RO 0 - I - 12Q E g - j N� WA,ERI .5' 4. oU i r I I 0. 5 18 Z 7,0' - 1 P I - 5.14 20 DI i -1kI 2 of'�-iF - ----- i 1 -I- 4,38 I -`- -- - - MA N - L -- --. __ -_.._. _ -- --- _ - � W vrz - - O U o w LL 9 - ---• i --�- 1- D+ 3r '---- -t _ �'I. +11 1 0 I I 71L= " J z A ER 1 0 0 J W vl W i I I L� I I � � I I R POE _ - _ 10 I I ' I _h I I _ I _ n _ _ _ a_ - -- 0 W. I J ^� ((Cop) ti) Z I m I ^ M _ - _.. _ - . W) O _ -� m l N W rn = r` T n n w ^ n 1 M _ } r Q Q : t` O e w '- 1 I �'r- .- O I W ...�.- :',- _.� m. m. O M- ': ~ d m_ - Z O O tq m N ` m rt _._._.._. L. = ^ - �.- O -_ M M-__'''+ '' _ _ p F- O a } li, ¢ } �OIO ¢ m 2 > ! Z m 2 o- ,- M - + m .� _._ __- 2 Z M m 1-' -i i _-_-_L f ____ m 0 m > - - o0 t- i� o _ _ �> Z., 2 a w to F- _-. _l m o _--... __ _ I-M M h m q P I __ m m Z_ O o- - d. Z .+ I r I w O a - m O F- Z �o r- �n Z m F- .d. vt 3'm a to 0 0 Z, o$- Z 3 N ,O Vl F - a ¢ cn c� o M- H. o F m c- w m oo a m m r0 00 m0 0 MO V'7 0to MV r0 0 m0 d-M rn0 am 00 rnm 00 �-0 170 hM I�� 1�0 00 mto M0 =0 00 a0 am to It MO In MM 0 rN m0 mm mn Ito m0 WM Nd) m0 rm ma ON (0M NO 0m a'r mM m0 00) Om tD� MM ISM mm ra OM oim ml� mr Oro Oim m^ O�1 ai`7 md= rd' m 0M MN N� m 00 O 66 00 Coco m 000 m h Opp m .-O .m ao [VO (V� t'7 m fV MN MN M� tM� 4O m m 0000 m m m m m m m m m m t_01_0� m m m 0000 m m m m m 0000 m m r r r pO r- n 0000 m 0003 m m m m m CO CO m 0000 15+00 16+00 17+00 18+D0 19+00 20+00 21+00 22+00 23+D0 24+00 25+00 26+00 27+00 28+00 29+00 30+00 45 z N Lf) CV LO 00 04 i 0 00 z 0 ° y 0U�o `A U LU p 0 0 U 0 (a=66J _ hG 0 X O v w �[ o� E� O m z W a o cr) i _ a Z _...n. e a`a� SEAL i9''' 031459, = y THIS DRAWING IS PRELIMINARY, AND NOT FOR CONSTRUCTION, RECORDING PURPOSES OR IMPLEMENTATION. c 0 .N m m 0 0 0 z Owner: CBMMPROPERTIES LLC CONTACT.• 238N. McPHERSON CHURCHRD FAYETTEVILLE, NC28303 PHONE:910-864-1125 FAX.,910-864-0938 Project: THE ESTATES OF GEORGETOWNI PHASE 1 0405-42-0744 tax Id #: 0405-51-2958 township: Rockfish COUnty: Cumberland state: xc WHITEHAVEN DRIVE PAVING PROFILE SHEET CONSTRUCTION DOCUMENTS job no.: P12-096 date: 12/02/ 13 drawn by: PDM survey by: JTR checked by: JAN sheet no.: C06 03 1 6 17 1 H (11A) 0+74.83 +� 1 . 8 ?INV IN 161.F OUT 161.0- rn � 00 31+00 !6 SS 00.50% pR 215.85LF I a SDR-26 SS 00.507 O N 21 22 SSMH (11) STA 32+90.68 TOP 180.36 INV IN 159.93 _----- INV OUT 159.83 + 34+00 35+00 PROPOSE 425LF OF 8" S R-26 SS 01.4 I �1 30 2g 28 27 IRS 26 25 \ I 0 o \ I + I � I I � I � , W � ]N 11 00 23 0 n + Q I� SSMH SMH (10) I 7�l A 0+00= OTTA 37+15.68' R36367.21 P169.37 1G / I V IN 153.54 I VOUT 153.4 - PI �7+15.68= 36+100 37+ 6 0+C}0 GR I169.37 .� 11 k78 WHITEHAVEN DRIVE 50' R/W 27' B-B STA 30+00-37+15.69 200 I II M — — HIGH POINT S A 3+1.36 - - y L .00 W 8 P- �3 8 VI; EL V = 182.00[ ''� 1 a _ - 10 10. C _-.-. _ _ -_ _..-. _.-_. _.._--- __- I.. _._. --•. _ _.. - _ _ _.I 190 - i- ICI 1—] 1 -1 ] 190 w _-_ I I I I I I I I I I I I I A,�I'n 1 1 1 1 1 1 1 1 1 1 1 1 I I I I I I I I I I i I I I I I I; I I I I I 1 T—im ww I.— - -- 30+00 31+00 32+00 33+00 34+00 35+00 36+00 76 - F w w -- w 5 z I U r 0 25 50 100 no r o 0 a0 n 17 2.5 �0 0 F � ( HORIZONTAL -IN FEET ) 0 1 inch =50 ft_ GRAPHIC SCALE 37+00 THIS DRAWING IS NOT A CERTIFIED SURVEY AND NO RELIANCE MAY BE PLACED IN ITS ACCURACY. THIS DRAWING HAS NOT BEEN REVIEWED BY ANY GOVERNMENTAL AGENCY FOR COMPLIANCE WITH ANY APPLICABLE LAND DEVELOPMENT OR OTHER REGULATIONS. EXISTING INFORMATION IS BASED ON CUMBERLAND COUNTY G.I.S. DATA. Know what's below. Call before you dig. Q d 3 N J p co O CV z c7 ,2 O m U p C CO, i Vol N pot co Z OCO 0 rcf) — LJr) 2 C�o ' xo� �bC w L on 0 5- Z w c M M O r � Rlin ®rz.,zp'Y'SEAL 1' % = 031459 E w W ...... `� O;;c Ytx """"mm� unmuo�••o• THIS DRAWING IS PRELIMINARY, AND NOT FOR CONSTRUCTION, RECORDING PURPOSES OR IMPLEMENTATION. 0 .y m } 0 0 0 z Owner: CBMM PROPERTIES LLC CONTACT 238 N. McPHERSON CHURCHRD FA TTEMLE, NC28303 PHONE:910-864-1125 FAX.•910-864-0938 Project: THE ESTATES OF GEORGETOWN PHASE 1 Id 0405 8tax05-5412-0954 040-2 township: Rockfish county: Cumberland state: NC WHITEHAVEN DRIVE PAVING PROFILE SHEET CONSTRUCTION DOCUMENTS job no.: P12-096 date: 12/02/ 13 drawn by: PDM survey by: JTR checked by: JAN sheet no.: / C07 ti N I � �,27 I �� _� I , j � � 73 � 17 o N� N C o m 0 6 iTl' �2 + o a CcQ o j O a I� 198 196 �I z G o 2 I ' I ' � ', I 201 1 � I / I � I 20 1 206 Iu+ I D 205 20 20� rn / SSMH (9) 2 3 I SSMH ( o w / � SS (6) SSMH (5) TA 14+88.5 + � STA 3+39.91 CC STA 11+59.82 STA ^ -' J / TOP 166.05 < TOP 128.90 = U _ IN 124.38 INV IN 150.04 IS I/ TOP INV N 1. 8 TOP 1 47 70 INV IN 118. ININ V OIN 115.2 INV OUT 149.94 115.17 ~ - PCR 0+ / / INV OUT 123.60 INV OUT 118.56 �,%" -- GR 168.40 \\\R 1+00 2+00 13+00 +00 5+00 6+00 / 7+00 8+ 0 9+00 10+00 11+00 12+00 13+00 +00 5 00 / 289.89LF OF 8" SDR- SS 0 3.00% 2 .14LF 8 SD 26 S ®3.SOi 239. 8LF OF 8" SDR-26 SS ®3.00% 164.56LF OF 8" SDR-26 SS 0 3.00% 164.06LF OF 8" S -26 SS 02.00% R- 6 SS ® 1.00% 0 --N -- - --- - - - / PI 9+19. = SSMH (7) o w //% 7+ - SSMH-11-0)-- / STASSMR (89.80 / 0+00 TOP STA 944.324 VOLTA RIVE EAST -> 0+00 STA 0+00= X TD 157.63 INV�1p��30•gg - + v^= STA 37+15.68 GR 16 .37 f V IN 141. INV OUT'Y30.�9 TOP 169.37 0 i R / INV OUT 41.14 INV IN 153.54 w INV OUT 153.4 �_ __ 171 172 177 178 179 D 173 18 7g 7g 163 1 g# 165 166 1 j 69 m t VOLTA DRIVE 50' R/W CONCEPTUAL PLAN ONLY PRELIMINARY THIS DRAWING IS NOT A CERTIFIED SURVEY AND ww � 7 � B - B NO RELIANCE MAY BE PLACED IN ITS ACCURACY. , 4 LO 11 o 25 50 10o THIS DRAWING HAS NOT BEEN REVIEWED BY ANY D O NOT USE F O R STA 0+ 00-15+ 00 GOVERNMENTAL AGENCY FOR COMPLIANCE WITH U q ANY APPLICABLE LAND DEVELOPMENT OROTHER 2, � � REGULATIONS. EXISTING INFORMATION IS BASED HORIZONTAL-IN FEETIS CONSTRUCTION x () Know what's below. 1 inch =50 ft. LOW POINT ELEV = '165.00 HIGH POINT ELEV = 166.26 ON CUMBERLAND COUNTY G.I.S. DATA. GRAPHIC SCALE LOW POINT STA = 2+50 HIGH POINT STA = 3+76.79 Call before you dig. ° PVI STA = 2+50 PVI STA = 4+25 180 PVI ELEV = 164.37 P v1 ELEV = 167.87 A.D. = 4,00 A.D. _ -7.00 mom K=31.25 I K=32.14 o j U 125.00' VC - 225.00' VC I of w +O N qN to N N En r� t0 t0 N (0r + 0 N + tm0 tm0 M .- + '0 in IQ- (nn V) / \ %1 W m m W m m W W 170 -2.00$ \ \ PVI STA = 9+00 PM STA = 11+50 PVI ELEV = 144.12 PVI ELEV = 142.45 A.D. 4.33 A.D. _ -3.33 K= 30.02 K=37.54 16 EXISTING 130. ' VC 125.00' VC GRADE Ln to LO mIn 00 m O aD LO N � M Wm 00 Cq PO \S00$ FUTURE GRADE 1 61 t;i 0 W rii 4i tri di m m W W > m > m W W Lal o U \ 39. 1LF OF g SDR 26 M U + W W SS ®1.00% r Q N w N 150 leg' 8g F OF 9 SDR�2 -- SS ®3 009Go tto o Mnm00 _ N It m. 7 -0.67% _ Lo to - \ in _ NQO>> - 140 F n � ol^ o + n 000N7 Q 00 0 1n .-- 97 ad N aR, �+ c6 93 s SS ="--zo rii W ®3Spy v�rQozz m V) V) _m I 130 8. r F OF 50R� s s ® 3 Oa9 a 00 tLo PO a m O .t �' a rn OR o r�- M �WJ ^CON 0 M �O =OMZ =FO)iIn n- O =mOtMN w.2z !0 �Z=00�Mjm = v0i�rQo» �aa NV) > sao (A » (aa» N�azz S ®3. z (A 120��NFzz N O t0 C) m i N N 164.06 . z p F F R- M ELEV n >> OZZ 15.00 6.16E mr r OIL MO NO O Min I�ppgg Nd M O INN n �t0 NN N N tnN m nN 0104 0 0 ON cc K, aDM O o NM O 0,*in0 r r VI N t0 M 90 d tp K vi o P6 t Of O LnV 6 U m t0 tbY 0 0 N i O rt0 1t0 00 I r` to rto (6 c0 tr t0 m to 0 Lo 07 mm 14 Its -0 a M MMImr MM 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00 13+00 14+00 5 CL Vf OC 00Oq IN p .V poi 0 0 °�� y pU�o Z i C CO O < J LO 00 X 0 t C Y J 0 } o `cc 1L M O a_ Z a� = SEAL 5 = 031459g y E H ; NE,%%%- � nnoea°", THIS DRAWING IS PRELIMINARY, AND NOT FOR CONSTRUCTION, RECORDING PURPOSES OR IMPLEMENTATION. C O .N N O O Z Owner: CBMMPROPERTIES LLC CONTACT.- 238 N. McPHERSON CHURCHRD FAYETTEVILLE, NCM03 PHONE:910-864-1125 FAX•910-864-0938 Project: THE ESTATES OF GEORGETOWN PHASE I 0405-42-0744 tax id #: °0405-51-2959 township: Rockfish county: Cumberland state: NC VOLTA DRIVE PAVING PROFILE SHEET CONSTRUCTION DOCUMENTS job no.: P12-096 date: 12/02/ 13 drawn by: PDM survey by: JTR checked by: JAN sheet no.: cog U i - / i \ l \ SSMH ( \ STA 17+ Qj I l \ \ .32 \ _ 1 I PIN2111.�� I 11 \ OUT 110. 5 l IN p0 19 00 19® --�------- -j IW\\ p 216.2 F OF S" SDR-26 SS 1.0 18 1 8.66LF OF S" S -26 0 PROPOSE 2-U SANITARY SEWER EASEME 00 11 0, / 00 --1 SSMH (2) zo a� I I SMH (1) �. STA 19+ .09 I DOGHOUSE 5' u I STA 21+ /�` I 1 TOP 125. W .33 SSMH 4 \ ( / INV IN 10 15 Q 1 TOP 12 .39 O () Od INV OUT 0. 5 w w I INV IN 06.89 STA 16+15.29 NI !^ XO EX IN IN/O\UT 103.68 J / TOP125aa 183 0 I IN" INV 12.6�oWwo I wl I Ayl i 03 I l I \\ \ 3N/)'�J _ Off° ,7 �� TOPS124SMH\ g y� ly A INV 104. 7 n �'V O I � I I 0 25 50 100 10 VO LTA DRIVE 5 `A / ' R / VV ( HORIZONTAL -IN FEET) F, 1 inch = 0 ft. w 27 B-B GRAPHIC SCALE 5 z STA 15+ 00-19 52.09 c 2.5 � 0 O Z U m + W U H w V) N W LOW POINT ELEV = 125.78 HIGH POINT E EV = 127.76 LOW POINT STN = 16+33.33 HIGH POINT S A = 17+96.18 PVI STA = 16+00 PVI STA = 18+00 PVI ELEV = 124.44 PVI ELEV = 128.44 A.D. 6.00 A.D. _ -4.25 K = 33.33 K 30.59 200. ' VC _ l 130. VC l O a p Ln Y to 0 CO <000ins+ 0)N V + r` rG + N r- N + OD 6 N OD + - v00 H n < N ZU lu U U U U U O U N�o>> > m U > W U W m m W W LOO rn N Z Z m F �0 o '� Oi N O; in "' LU into c0 O \ N + O^ j + M 0 - v0i Z:1 _ - O "ONNz> S S z m< Cl >> McD<n-> NO-O X '- NN Z__Z rn C)U) z W _ EXISTING GRADE 2.60% FUTURE -2.25� GRADE 1 6.1F 0 6L ® 8 S ,4-, R_ L� M M OF S R-26 SS 0 1.0 % � M M 0 N u1 N r IN216.24LF c OF 8 SDR- 6 SS =--=o z�--ZO » >> rnm rna 0)N 000 nv Lnrn oN ro00 rnv PO Nr- It nv at <r rr) r)w LnN ^0) OGD MN 6t6 NN mm NN r\N NN rm NN mn NN Or r7N Or r'JN NN N 15+00 16+00 17+00 18+00 19+00 20+00 21+00 22� CONCEPTUAL PLAN ONLY THIS DRAWING IS NOT A CERTIFIED SURVEY AND NO RELIANCE MAY BE PLACED IN ITS ACCURACY. THIS DRAWING HAS NOT BEEN REVIEWED BY ANY GOVERNMENTAL AGENCY FOR COMPLIANCE WITH ANY APPLICABLE LAND DEVELOPMENT OR OTHER REGULATIONS. EXISTING INFORMATION IS BASED ON CUMBERLAND COUNTY G.I.S. DATA. PRELIMINARY DO NOT USE FOR CONSTRUCTION Know what's below. Call before you dig. i H O LO OC NC-C? CN 00,0 2 O V O a3 U °= f00o Q Ito O O 00 (zm rn C� ce) O N M o C hd LA a) - 00 J O Q O - E �[ ca } p c)) TA U CL cM LCL3 C� Z W-SEAAL _ � 1 031459, F N0-1; 'AN'�C i `,` .Q"mmimao`d O `. nnw`a `P�� THIS DRAWING IS PRELIMINARY, AND NOT FOR CONSTRUCTION, RECORDING PURPOSES OR IMPLEMENTATION. 0 .y 0) 0-' O O Z Owner: CBMMPROPERTIES LLC CONTACT.• 238N. MCPHERSONCHVRCHRD FAYETFEVILLE, NC28303 PHONE.910-864-1125 FAX•910-864-0938 Project: THE ESTATES OF GEORGETOWN PHASE 1 0405-42-0744 tax id #: 0405-52-1954 0405-51-2958 township: Rockfish county: Cumberland N d a d � a: h Ll*) 04 O OG C�O 04 � i3 .o 0 O °' 00 11111 00 N W = L L. U E O 0 oo m co Z M C Q v C) O N M U hd LO �ii = oc J x O > SL CO � i� Qco M TAU o M l o Z R H'� `9 a SEAL THIS DRAWING IS PRELIMINARY, AND NOT FOR CONSTRUCTION, RECORDING PURPOSES OR IMPLEMENTATION. c 0 X a/ m 0 O 0 6 Z Owner: CBMM PROPERTIES LLC CONTACT. 238 N. MCPHERSON CHURCHRD FAYETIEWLLE, NC 28303 PHONE:910-864-1125 FAX-910-864-0938 Project: THE ESTATES OF GEORGETOWN PHASE 1 y 0405-42-0744 tax id A: 0405-52-1954 5-51-2958 township: Rockfish county: Cumberland state: NC JACOBS CREEK CIRLCLE PAVING PROFILE SHEET CONSTRUCTION DOCUMENTS job no.: P12-096 date: 12/02/ 13 drawn by: PDM survey by: JTR checked by: JAN sheet no.: C10 \� CO 11111 c 7ro Oe G� psi / > ?s o Q Z)� Jd ^� CID ° w o Q417�`4rncu-iL CO (3T IV CO cc QDh O')''a) IV yyh 4� jOJ /R.. _ 03 300 n oG� o of o� ° m n nN 40 C' h QID � ) Y, SS t�1lj g IT Q s8X 4 � 1Al b b1S <� 7411 <1 h 7410) voi 0 h N m ^ \8886xZ O ` SO 081 - 0 25 50 100 F 54 w ( HORIZONTAL —IN FEET ) ko 1 inch =50 ft 5 x GRAPHIC SCALE U q 2.5 y LOW POINT ELEV = 171.96 LOW POINT STA = 15+14.59 n\. crA — ta,Qn In i 4roco mNc;,o ^ 7�n Sl i ENO r N ^D�a 0 12S 'E3 -312 OQj OF'-177.85 JV-170.59 .8ROPOEEDREEK ALVE STA 17+90Cpi�G Rnr , ® P 78+ 177.0p4'5 B-314 TOP-177.85 IN- 171.19(316) N OUT-170.69 �NC� �.j^n 1b10 \� fz� 0 NNJ 'f1/7 4voJ _ o S<•0</ JCS \2 SZ81t s S<•9</ bIS 8" PLUlS, W/ 2'BL STA 18+50 JACOBS CREEK CIRCLE 50' R/W 27' B—B STA 15+00-19+12.18 PVI STA = 17+50 �Hd JACOBS CREEK C '7 APRX 198 - © 1.1m EX SSMH ----- TOP 181.56 INV 175.45 BIRCHCREEK SECTION 4 PHASE2 ■n■■■■■■nd1�lF7�idln■N■■n■■�i1LJ�g�■■■■ ■■■■■■ n■■■■n■■■■jZ]nnN ■■■iil!y'i■■ ■ ■■■■■■A ■n■IIII�HE +I ■n■!tn��■■■■ ■■■■� Iili■ n■EI��I" ����■n■■■ ■■■■■� tb IC I;k• I a' .' ' ■■■ 'f'ilt»t■■ ■ ■iiitih�_I��Ni_�� dNi� • MINIM ■■■■■i: ' ■■---ors IN ■ .■ ■■■�i ■�■■�■ ■III■■ ■■■■■■1.■■ .Fill" RNONE ■ ■■ -'.. ■■IF !■■iii�■1�■tii1■■II!"�..•'�� -. ■■■■■■■I ��■■I ■■i.�.iiii�l■��■�■wJ Yi�ln� ■■� i■III■■►%■i^Giiiii mill■■/��. 2 �, %� - ■■■ ■■ ■���: ■■ ■ �G�■■ ■_ I■■N__��iN■■'�II'i'��■I,11■ _ ■ ■ ■■■■IINI111I■ii C�'�■■n_ /i;�■■■■■ICI■� � �■ ■■■IIIII■II■■■ /ii/!itiill■■I■�I�li�l■ ■ ■ ffifffimmillill �Igim■1■■ �. �I1■1�■a girl■ ■ ' ■n�� �� � ■■ ■a■ ■I II■1'J�1�1/IG/ R! MMIll 1 � 0 0 ■■ ■■ V 11■IIIv�_a35tCI�•�i1=�%11`1,■�i{IW■■�IN _PU iI■�■ ■ ■ ■ �■ �� '�.i.��.T.1,,liiiiii'II�/'■���,■■■IB■III■I/i71LR,�■■ II■111■■�I�•�■■■ ■111■III■�■■1■■� ■1!III■II!■■■vt■■■■�■111■IA.■■■1�1■I"n1■■■ ■N iIL■�r!�!■��_■4IFT IiiiM■■■J�ILIIB�� ■ IN ME 0 MENn■■IIONE 1 I■■I■■■■■■■■■■.i■1■■lInME■■■ �n■ ■iii■■■ ■ [�11tE ■1■I013M ■■■■■■, IL'!N!■■!�■�I■■■■ ■pa IIn■■ ■ ■ C ICI !■1!?7■0■I�!!■■ME NO���!�0■■I��! ■■wE� �■E� ■ III■! ■E■I�-s■■■- 9116- -■■■■IE■i ■■tll� ■�; ,. . 15+00 15+00 17+00 18+00 19+00 go] a 170 MR 180 1 LOT 127 180 170 160 V 1 J LOT 126 170 160 CONCEPTUAL PLAN ONLY THIS DRAWING IS NOT A CERTIFIED SURVEY AND NO RELIANCE MAY BE PLACED IN ITS ACCURACY. THIS DRAWING HAS NOT BEEN REVIEWED BY ANY GOVERNMENTAL AGENCY FOR COMPLIANCE WITH ANY APPLICABLE LAND DEVELOPMENT OR OTHER REGULATIONS. EXISTING INFORMATION IS BASED ON CUMBERLAND COUNTY G.I.S. DATA. / Know what's below. Call before you dig. PRELIMINARY CONSTRUCTION r Q �-- a: z N C)L0 ON 00 � z j C 00 z a "' CDo�� y C p, 00 0U`o z N a S U E ^ooS�o z c C N C ^ (D -0 M C N cM O C Lo2-cOJ 3 XO O N � Y J w .. cod}0 � o- iE cM m J �cM ��z n n e ..l ..1..., vo5S1�' liO, AN FQ'G 111110% itmu m...... THIS DRAWING IS PRELIMINARY, AND NOT FOR CONSTRUCTION, RECORDING PURPOSES OR IMPLEMENTATION. c 0 'N m m 0 0 O Z Owner: CBMM PROPERTIES LLC CONTACT.• 238 N. McPHERSON CHURCHRD FAYMTEVILLE, NC28303 PHONE.910-864-1125 FAX.•910-864-0938 Project: THE ESTATES OF GEORGETOWN PHASE 1 0405-42-0744 tax id 51 2958 004405 township: Rockfish county: Cumberland state: NC JACOBS CREEK CIRCLE PAVING PROFILE SHEET CONSTRUCTION DOCUMENTS job no.: P12-096 date: 12/02/ 13 drawn by: PDM survey by: JTR checked by: JAN sheet no.: C11 U 8" X 8" TEE \ ltO 13 3OVNIV21 ,oZ "-',\��W/ 8„ GATE VA 0-10= STA 17+17.77 'J`Y�� 44 O O.9Va`' C�� O (0 - + 3 IlHO1VWSTA 0 'oFIRE ii PROPOSED HYD T ASSEM > o 51 fir- O a �S' 4,6)x1i,StiVq OL`'l'g° "/ /O��co 0 `.N0 'ST +47.16 r� ou? 53`090 >a0 A �'°o"\ O ArR ro N v o O w o 7 4) O2 76 C -322 1++ TOP-182.57 II �` �j SSMH (19) o o N N N o a o STA 2+12.0 00 + rn + 2 TOP 181.35 `� `+ n+ Z ¢ o FIRE CB-328 0 PROPOSED T-176.33 o I ro HYDRANT IN 172.73 N m ASSEMBLY 1n I 172.17 STA 15+46.0 *DI LATERA I ------ SEE UTILITY 165.11 C FLICT DETA w I �pROPOSE y\ \ \ 6\ \ �z N-178.62 _ TOP 317-9 STA 5+29.03 ® ' z I d0\ \ \ O OUT-178.12 4" INY IN 71.57 53R ii "o\ \ �' ___-- --� \ O 7 IN' V OUT 1 0.82 INV-175.13 o p 8" X 8" TE I o `'\ \ C. \ ---------------- / 0 ® 237.3' 2 "R P 25.50•-15" R W 8" GATE LVES TA 5+82.95= o I A 16+43.85 y--- \ \ / 5.10R x R OXg 3gy 2+0 GR 176.28 Nm 174.- + p SSMH I 0 8 602 16 3 00 5+00 cn STA 16+39. o n SSMH \ O STA +00= Q� S 17+07.77 p� OP 187.87 7.87 380.90LF OF 8" SDR-26 ®2.0 4+00 _ .. S (20 168.42 u STA 16+53.8S_ STA 5+92.95 \w \ \ \ INV IN i STODDERT LA 1 LATER L P 175.01 S UTILIT O \ I I INV OU 175.36 ; ; CB-323 25.50'-18" RCP \O ® Is po NVTNy IN31204.00 CDOTA ICT �- G O\ \� _ - - - - - - - -_------------� 45 O / / / / TOP-182.57 0 0.20% CB-318 TOP-179.58 PTR 5+5224 GR 175.95 � -' rn INV OUT .1 �L-- � \ L-- --- ----- --� ----�- i OUT-178.72 �j7 Q �, INV-175.08 ¢ \ l+ CB-316 \;\v o _ C OZ \- 30tlNItl2i0 �i _ CO M N °+ +" N N N N �_ O N Jv c 178. IN-171.33(3 J ` Z O STA 17+22. L-o <; 1N3WStl3 O --------- &9 �OILi-j `� + + �O�J IN-172.63(328) �rn OUT-171.33 0+ 172.21 w O �jr' ,L`LI` -._ _-- - �ei Q P [ ¢ /.. J o � UTILITY Iy DETAIL l O __ w o U N r ^ o2 ^ o o CON ICT o a op JiU \ i n \ ' G1_ 484 7 IZ 1 \ � No O\ O '/ C,'LP � i/ 0) O.O �'� O O V 0 25 50 100 ( HORIZONTAL -IN FEET ) 1 inch =50 ft. W GRAPHIC SCALE �w x U U 2.5 a STODDERT LANE 500 R/W 0 27' B-B STA 0+00-5+92.95 II n PVI STA = 1+50 PVI STA = 4+00 cco PVI ELEV = 181.97 PVI ELEV = 179.47 n n o a0 A.D. = 2.93 A.D. = -1.30 +a K=34.10 I K=76.83 0 0 100.00' VC 100.00' VC 150 1 0FL J ¢ C) m �: O ^ W F 1n f/1 J ¢O� r o > a ru x o ¢ ¢ 3, 93 m m W EXISTING W ® N fr U I in W + ro n F WF U InwU In + a m WF wwo J ®� ¢ nut wm a1p3vi0 GRADE �-� ai LL mU4 ZJ n„'4 Z Mo wwm°� w ¢ W F- Iri 00 c n O n ink F ] N .o W ,eUZJ OQ ZOQ In �O0r IeUZJ lJ ZO¢ vl Ur 00_>_ OH¢N� W_ p/ NOn� OInO �p 1 1 N w m w> U nN WO JN U00+ w (nTm V)00 In In PROPO U ®J � a 'oIq _ ?o GRADE ®� aEaN aro3�m a+ Na�ozz wo(nrzz 180 1.00� 160 237.11 -24"RCP 07. gq, �?• 0% 20' DI \ WATER 8 PVC _ 3.74' 153.9' 30"RCP \ 3.2' 0' DI ® 4 20' DI n NA EROD WATER 1 \ N� 0 b `n 0 of 3. 4.0• "1 I 170 71- JJ m moZ U r- n mo 380. n. o \ 70 II r: n � m ^ LO I ­^,no rn+ ` 90� OF 8 SD U R-26 PROPOSED 17 +^000�? in + nN OD .zr SS ®2.0 09 °No�� n 36" RCP \ Z Z�= I > ATUM ELEV zz m � n F- zN�NP o? '., 165.00 \ - rnn N mo rna Nd In n mn A nM CcC N�N - n O�0 �0 N \ / a)r 0000 rn mm nn m00 nN m00 N 0000 m00 O NO m00 0 0i 0 On n nnM �� n 1 1 IaI n m� I I mo �ozzi� o 0+00 1+00 2+00 3+00 4+00 5+00 ts0 r n DATUM ELEV 150 150.00 In 10 rn In o ao 011 n rn 01 a m w 10 CONCEPTUAL PLAN ONLY THIS DRAWING IS NOT A CERTIFIED SURVEY AND NO RELIANCE MAY BE PLACED IN ITS ACCURACY. THIS DRAWING HAS NOT BEEN REVIEWED BY ANY GOVERNMENTAL AGENCY FOR COMPLIANCE WITH ANY APPLICABLE LAND DEVELOPMENT OR OTHER REGULATIONS. EXISTING INFORMATION IS BASED ON CUMBERLAND COUNTY G.I.S. DATA. PRELIMINARY DO NOT USE FOR CONSTRUCTION Know what's below. Cali before you dig. Q _ z z y �i 0 � p 00 O C14N z z .O � o 00 a 00 o y N DU Q^ 0 p O U Z co w a) CO N < M N M (� C7 2) WL Jorc mX O tN� 'z° w J M'� 2a.Z �M 9 SEAL �l 031459 c' ul r" 4, A a0` THIS DRAWING IS PRELIMINARY, AND NOT FOR CONSTRUCTION, RECORDING PURPOSES OR IMPLEMENTATION. Owner: CBMMPROPERTIES LLC 238 N. MCPHERSON CHURCHRD FAYE7TEVILLE, NC28303 PHONE:910-864-1125 FAX.•910-864-0938 Project: THE ESTATES OF JEORGETOWN PHASE 1 040542-0744 tax id 0405-52-1954 0405-51-2958 township: Rockfish county: Cumberland state: NC STODDERT LANE PAVING PROFILE SHEET CONSTRUCTION DOCUMENTS job no.: P12-096 date: 12/02/ 13 drawn by: PDM survey by: JTR checked by: JAN sheet no.: C12 1 8.32 p � � ST 5+93.81 + � j N � 173.50 � cv a, C_ SEE T T COPN CONE TDETAIL D (� � 178.2 on STA 6+0 .78 �o ® 17225 0 > SEE UTI T \ m O CONFLDIG DETAIL 2+85 177.6 2+0 — I� PROPOED STA 6+8 •59 E AY COURT 50 R "GATE VALVE 173. 9 RO ATE 1+0 SDR-21 / STA 7+Oi3.99 SEE UTIL Y CONFLIC DETAIL SS H (25) _ % PROPOSED S A 0+00= 8" x T S A 7+00 LL VALV j T P 177.58 STA 7+10 i IN IN 158.42 °r STA 0-10 1 V OUT 158.32 w N�EVERMAY COURT 50' R/W o�QOOLn 27' B—B N7+ 1 oN- QQw 1=o :x�IQa» STA 0+00-3+23.50 0h(n-0 0- ro 3tn to to tn�-ZZ 180 d 170 15"RCP \ FUTURE I� -2.00q, 1.55' PR OSED 2" SDR-21 WATER ow . w3 + 00 aJ 0 m a N It 00 h 00 000 r 00 rM W loco mUn 1 iq U�Lq rnLq ovl am i, to inN av NM NN O� n nn nn rn ran nr n� 1+00 2+00 180 �7` 3+00 CONCEPTUAL PLAN ONLY THIS DRAWING IS NOT A CERTIFIED SURVEY AND NO RELIANCE MAY BE PLACED IN ITS ACCURACY. THIS DRAWING HAS NOT BEEN REVIEWED BY ANY GOVERNMENTAL AGENCY FOR COMPLIANCE WITH ANY APPLICABLE LAND DEVELOPMENT OR OTHER REGULATIONS. EXISTING INFORMATION IS BASED ON CUMBERLAND COUNTY G.I.S. DATA. PRELIMINARY DO NOT USE FOR CONSTRUCTION Know what's below. Call before you dig. d z y z 0 Lo J N 00 "T N i 0 Oto z O N C �•O U 0° 00 H 00 0U o N >Q �toU0 > 0 0 0 N U 68 00 CZ, �Q N r M 0 N M 0 t9 C = 00 in O z be X 0 'IT Y 5 J W � m ` } w J z 4— M O ZEi ryf'i 9 SEAL 031459a @ y A THIS DRAWING IS PRELIMINARY, AND NOT FOR CONSTRUCTION, RECORDING PURPOSES OR IMPLEMENTATION. Owner: CBMM PROPERTIES LLC CONTACT.• 238 N. McPHERSON CHURCHRD FAMTEMLE, NCM03 PHONE:910-864-1125 FAX-910-864-0938 Project: THE ESTATES OF JEORGETOWN 11 PHASE 1 0405-42-0744 tax id #: 0405-52-1954 04 5-51-2958 township: Rockfish county: Cm bn land state: NC VOLTA DRIVE/ EVERMAY COURT PAVING PROFILE SHEET CONSTRUCTION DOCUMENTS job no.: P12-096 date: 12/02/ 13 drawn by: PDM survey by: JTR checked by: JAN sheet no.: C13 tl 1 I Q _ d z N J C) N ON 00 N z j O Z 2 v C/3 o C ll c p p Q' 000 0 U to N Q O O :toUo O O O 0 U (00 M C N M -0 a Y CO X O N' C W ` m S} �` J L (h >- � LL W ° LIE) a_ z O c ` �9� 9'''? J SEAL 031459� y srn - -FS'tp •' 4i: 111n�pP�P"0 THIS DRAWING IS PRELIMINARY, AND NOT FOR CONSTRUCTION, RECORDING PURPOSES OR IMPLEMENTATION. c 0 .N m m 0 0 0 z Owner: CBMM PROPERTIES LLC CONTACT 238 N McPHERSON CHURCHRD FAYETPEWLLE, NC 28303 PHONE:910-864-1125 FAX 910-864-0938 Project: THE ESTATES OF GEORGETOWN PHASE 1 0405-42-0744 tax Id 0405-52-1954 0405-51-2958 township: Rockfish county: Cumberland State: NC MICHLER LANE/ McCANDLESS COURT PAVING PROFILE SHEET CONSTRUCTION DOCUMENTS job no.: P12-096 date: 12/02/ 13 drawn by: PDM survey by: JTR checked by: JAN sheet no.: C14 n. Vf J 04 O � OC 0OMa0 N 0 t3 00 V a .0 N 0 o� z3�� O D O' to Qe8 W Iz- u- U o ^ 0 000 C1 CZ �-0 1 0 M N M U_ C Lr) O: _ 00 J �C X O > " YJ N 5 ca ` t ll OM >-�U o M a Z bq,nuroa�o� 0 ter: THIS DRAWING IS PRELIMINARY, AND NOT FOR CONSTRUCTION, RECORDING PURPOSES OR IMPLEMENTATION. Owner: CBMMPROPERT[ES LLC CONTACT.• 238 N. McPHERSON CHORCHRD FAYETFEMLE, NC28303 PHONE.910-864-1125 FAX..,910-864-0938 Project: THE ESTATES OF MORGETOWN PHASE 1 tax id 040542-0744 0405-52-1954 0405-51-2958 township: Rockfish county: awbulamd state: NC DRAINAGE PROFILES CONSTRUCTION DOCUMENTS job no.: P12-096 date: 12/02/ 13 drawn by: PDM survey by: JTR checked by: JAN sheet no.: C15 9.0 9.0 � 24° � T<7 GRASS GEOTECH LINED FABRIC SWALE TYPICAL DRAINAGE SWALE SECTION ca e- NOTE 1. GRASS SWALE V-DITCHES SHALL BE LINED WITH GRASS SOD WITHIN 7 DAYS AND RESEEDED AS NECESSARY TO MAINTAIN A DENSE VEGETATIVE COVER. 2. ALL DITCHES SHALL BE LINED WITH A GEO-TECH FABRIC. Drainvge•-losell Mcence drnim in bcetinra wi,h high .He labk, To u mppoblcros OWwwlainhibnemeblishrrl avegeutlwln Nechann6. Store,w ll bodwm finingrNybeebbselvBmepMbaemlawflawuao- Iklp Kd ad,meno volume Newrkuof fi dries; th facertpnHs(PocilYmrd41, Oiry ond,XUXeIMem fmmermbn b/limigng IIIGeall vGwiry Ipracum E41.Otu- (u51adG3adpn SaucrureJ. gedlmeoWlop prmeefloe-P[aKC1 µimercni muss onal fach sediment pmdreed in The wmmslKd, aapcciRy during to mn c� reddi This Les ho swmPti3hW by dm dlsdve um M diversions, sediment Isp; pmwwYN .tide inlem,aM vegeudvefrker strips Chong lk cimrnd, Construction f, Rembveen rtem.brv6n, slnmps.vM arM<eblecliolwLle mweaial rrom taco Specifications mendmion."dispmeoflNaprly. 2, kxcaveK me<hmmla,tl9apehpnrallincsuMdimmsionbiM«non the plans plus a D.2-R ewer vwltl Me bhanrel primers M allow fw Milking Olnngamdbed pmlXmtiow and mdbuildup. 3. Remove and pmpmly tlispose of m exs®coil w Omt sated aseKr may wteydmm.1fmcly. 4. 'IlmepmacMmuc usN m lahliah gmse in me cnwrcl will depend upm Ilse Sev¢riry a an, defideas and.k - of of eeies lineal She Channel wiN mina w R mmpwmy Imw sufficml so entanglesmdcil.d velsines dining de edeblishmcm ppad (Appandle 805). Maintenance D.Ragi Me smNidrmcat pedad; a gams-Indmi bhvinas anal every, rose. RILL A gaff is cPaWifti paiodieallY once Ore chwdel; ask it Star every hmvy taro WI event.] me my make repair,. It M PwcuWly impary =I to chock the cheerer dams and all Iwo emssings for bank smbi4tY Rod IMENRn birth, In Rmm Wl¢E. Remove all aignifrcem xdimmlmY..a lions To Iwittmin the designed reel opazily. Keep UX gars m e h of hy, vigorouscondition mealtimes, ffirmaitiN Mdryin eryradian praraAw fix the bibelot (@Cda 6.11. Permanent Ssdmi BMP-1 DRY POND INSEr- ef, 5' Crml wand XMdwmbb nxaswMde A,00 dkd'Irercn. backflletl // 'If XMea[. olwgaesf mticammcMd � %< Irosous uPnfs rrt«eras 6.6n CLEAN ONXMBI masuGmd[e COXSIWOIdtA�XGl10X aEpMBkIREACXU ' McMEL R - 75. 2{Il Meas `dg Ci¢r 1. Gmae Ind lamina Met This bmram'n ravel hpnla hockaddnde sera retain. Emegericyspe 2. 111 Posts awe nrewltlm amR sndlmmircw-Rmeiancemalmnm r¢nca aatannn¢eaea. TRENCHING UEiAIt aside bonds, open Eorn 3. slampo,0,nawe be Ynenmompm of zs rem spaced a mmmumot4ftoPmoralr:dal W IsxolsunaceArea me sitlesalllre baFnmweu.lM taP of 'no latyb RoAtl be 6 inches higher than me MmM or the sPlWay. IaIn MBas,aan8cm31 Tam sir Is snwlem2 man, lower Man 11 too I me..Wnkmenh. aPrt mkM ranee max sir homes between mn tat aaa onest discharge pdm. 9oauled nwa 20 lest AZUrER OL IPIv "an 2kMflm'. SEE of FOR LOCAfyi WMn son, posh, ado a-PMr aim ar rage aa® Me by of the meosunb preronf so�rg. 6. Wrap mare over the too will ire mend should I Ma to ten dream ep ton More wsare.5ea a., fa M dealer, erne fvMc la a rope om n:.wf shutlnre w in np fins. wind a slap Ed 1. The LHhom and sues or me rearm Ywla be oneoea In a month a poem well Ciro emom anal 1' Free�m EwsweBn nmw Not maniognames. AA nmmomenhsmuthe constructed No 9. Do rwxpl,a me mhos Mil use o mrMnnauspiece aaos the basin. PSx aomyform, abroad Kasper ASTM 5'Tln Emg414}' e1 Mg Do% Test M 5mmnmenh Mail be "Newma permoould n;m"minmum to .road no mulched as speclnee. lrupshi bander at least once a week aN any Room hall Mnke any Ivdured repairs 2y immeepleN. Be over to mmiman occes a the mmez. Samoa Tm bGic or o mpg cbllopse, led', decompose \Z;-NOTEi abecwnavm rally .repbca irsr7 tyONSTRUCTION • Rcrrove mdimenf deeded wren it m "1NI ho pavan meloohe slgaga voum Mr the ad,d lax! son add to reeuce padre an Me merle. ran come to ovola damaging the mmm etmmg cleom9aar.5BCFTAn1 mPrh shggd re9 eaceod open me des dableurge dear, Arc me mnmbufirg Mahan' area has been) stobnaed. mnave al more momTah and SKIMMER BASIN uelmed mdimenraepoals. btng R'e'aea ropoaaam sMbl it. CROSS SECTION SKIMMER SEDIMENT BASIN (Penance 61 CIX15fAULTON SPFCIFICA1gH I_ Clem.pmb. and ON IFR Fred uMN tie amba,-Flolall veoepope, ana of mahf ornove all sudoca sdi mnlainingngn Orep-110 Wgank mWteramfIreskpikbdshospe Olitpr000+Y. Yo-aA meclanobb moleibllo me dHigrgim daposol aaa. Placefeivromy IDaishoodmlm: aebw enures neeaea. 3. Enras re Mal I Ilse of tar the emmakment'IS area al not woody vegetation, bo om. on.pem antl other obledbnoblR natedaL Raceme Thin Ilm not to exceRy 6 irchms to allow Iwmdiment 3. Shape Me bran To mespeciAea ciromum.Pre.erl Me sdmming I -a from nam ing lor. m¢polls by eacavainsa sholW at untler inn skinm9 orgavamg a aw support untler In. nurmarof sun. of Umber. 4. Place the barrel Thpleoly 44nm Snedme. Pool >-el iNi 1. foundation of impervgns 1. Do not use 11- ma lvan as sold, grovel, or.-. more as Lot O%md me in be Plane Me M material around the pipe spend,, In 4Tm iwem and compow E under oho Ound the pipe To at!easl the same densXy OSire adpcenl emmnkmenr COR moil he token not to raise ire pipe ham hop Nm CMtOCt Mln ih Ishi on when norl' ing bids me ape up-res. Pore o minimum depth of 2 teal OI someone. prei over the fare Minter, abode Wising If wMM1CmBTucllpn on.dment. In he Cave di The pipe candun de Im ai by cutting a March bougn me dam arms me emmnl lent is comgela 5 1, he cchlem Winand followonly me no, of In. o nsrtUCh 11 eras desgneb. 6. oy,ne adembiea he n The ao m n - lM1 dam lr. M sure onsish eh of M bone mmo yNaold an Pa Ae bop t Ind band Thee and poiX rn l arm pose savpon Be,nre lc anacn aropmro MR SNmma OMdrvcndln mend Wm med. m n ureic pnnme Sinumenlaw fir in l' M I Flemish and entrance - A ew charm l dMarep a to R0 ,newer eahmt dastiole e s aaevmem of ebnrea dbe Load grptla, design at dot Mean channel slap 'R t into INarbug ftheryNNy.ew pansyn Itl be c rein oneuthe surnporncluor bleg Thole Iodic. Ref a< 1 vM d g agnT mm� he need dwbN ornolftR lop of me and Id once g' 1 h Ire d lve less, ed 11, B' ch q pre, Rre 1 yK mt m Idly ugr, Cameo dawn the gape and evl onto be gro 'he wiaM 0 me t must be cres piece, notjoined pl do opmewas worst ccom get now file MMc I the Mono of mo 1 lark Nnc' h Podiatrist di t gm 1 m rig ro mo g m qm Lm of m Fred. Me upper sennnslswa .mapmelower rman sl so r-walmr nrrtonww was the ma6csevere me sipper Mage ana saes ol+m ladic'rvartorinn rslesap R. Inoae-D�Ch lye fe M Ire m " .tap Y .Use tempd'ary dace tlM m or dvemms who wIM poTeclipn la tllved d Y. E Cannot ha Construct t ict naarTrustee tint re UTMab hin el'rrah Ohse- surface worn army d a ., arms, dab of Ire m kn 1 mla'e m cleared Slab4ee m meq q plMvy mmnbnenr and aB MM1er tlaN2ed areas amve fM1m creA G Mre a' G houisay' a 1 N n h Y 0 porous mnb p Led Pm a 6p Bo 1, An A rem hes sea h pM T9 a Dee- aelm ran1Y sfabi d� remove He smrrne a!M an dam choose,sedmem soldm Ida areo to blend-11 m d'dng .,am and mmd,e wpce-.. MAINEMANCE idsol stimmd mermen burns Of least weekly and _'ter Coat fgnil Oni inch or n'eoierl ra'Mail event and sera r Imm¢dafdy. Renown, sedmenT and mAae Ire basin to its or inol mYnawiS.1 rcaiment oonnotbes to me-li the nemM of 1. fie lame. won Me Yimmd To OM sae so toot Ind solvent nnae mane tt can be b aoradh Fi{Ovpte ma seennant ham Brie hone barn. MI11 arWra Ile. -a, or The Not Mill mate sae Mon arch growing In me bottom of this ream does not hod down the edmme,. Lades, the mmm R they arm command 1.f ecrw Mir a l,l- In, s Town, enaemesn or Found mmm, r me sammmris Hogged aim brain ana more a wttter -happen usaolHFddr9 me rope wX mote ma simmer dal dr ana darn and aishlge+ne debts and region new. If the does not wick I the'immer over to Ire nee of the basin and removm me dean Am check the again inside he skinner la sear i, it is logged. itsa 2mave Me popme T Me simmer are on posses pion Is Irso .me apple :Onfor removed and the ommnion caused wm a bombers make or by rating with wale. Be sure oho replare the probe belme dMithotnre t^==tlmmm. clock the mart,lined sperms, Id damage and mote d'Y rxlutmd.,.awill mi that forces the M watn al Mulsgllway, Clock the mmIddpM c splwan. ana oiler far Mrosbe dorm ana tmcecl -embankment for moan, me sentimentmake on neCedary repots lmmmaaMy Remve an has, and of. a.. mom Ida commm ma pool dram, Freazmg weather can 0.11In'Iso forlorn, -r Ina mar come ,Canal gecwnons amble of In thom o to attend' 1. sdmme, mom plmgnng win toe. Temporary Skimmer Basin w/ Baffles Reference' NC Erosion Old Sedimentation Control Planning and Design Nesmi - Practice 6.64; Practice 6.65 I Inlet Doorl 3s SCH 40 solid poi barrel or "any" supplied by contractor NOTE ME DESIGN LIFE OF THE FABRIC R 6'l2 MOINS, MT MAT NEED 10 BE REPLACED MORE OFTEN IF DMAMGEDORCLOGGED. a6ENKY AND INSIAIIATON I . due M Me 4' INm ealerucn 10 Me I¢e on th i me 1. INiU ere vent 3. Give IM1e B' lerg Tsch W baelle M¢3'wbbing dolls'em. 3. Put the amen drat .1 the baml into Me socket on the irm'etlntiin ono Flyer the,rewx. e, Del 1. mice mMe ably, Put the ably M The Mier, and hipper Ilre wow, ado Me bow. 5. Cum a panes In the mnom of Me man 1- to 2 bees -Mr erne me,tlmeTBr we m normal II ressi pats a mPPpanme- 6. Mep Ing mullet Anach Me d"cwoling ca Met Ireor HIS OpIand M Mince_ S. Ail a f merope .o Mre Mee on ape otter antlro mstateon Me side.1IM1e man. S. Pill o fence rml. l Fiat 2. on the oPPostle sae of Ma Wsl man where me mpeu fir too Bloke b tees IM1e simmer in pace. NOTE: Put the sinner alarm you wall X m IW. to MR action and m'o o merol reran Mm into the grWm on the MLI of me baby forvy Iran the ad.) 2' ham the ryd'a hold Me skin, in Me, pace. Make are n Is MEN emugn se the barrel dam not Boat over Me by when The been M, Pods on band Ades of Me lama she not reronMerked mCaued 4 WE! govem defy, this Wmmy To Me We Iw^simelunco. 4"inlet extension MAIMENANCE . TRAiH: a to hint sommn diem and mere B-He III Her Mr. funding m me don, 1 ff. Mil usually wash Me prom aX ana trade raw r rot PLO the mat To Mw sons a the men add me a sack M clean the,crem. Open Has lsppii E7Lr t1'tbF'k`!W ,[Fi' 'i;II [v OG35isaLmlliS "Onstri CUrf n v 40 coupling reen dMmnd removeamlmshwsedlmenl'wm al}an orleas do. pro nMe-mac accord -in sit nr r _liniments His4"SCH • SEDIMENTACCUILLAsT10N AROUND MESKIMMER:A ML brg hat uerq cables. antl NBowln Me man of the ICr UII10 i br he U r11Wa12 PI ^ll; hIJ 1 rd/CIin,S connection oppado one mom Me..t irelp keep xSrome-1f the,bmmx. If,edimem m,MCu,limmer T9ssment the Wormer To see and Incawte urn it- 'ides regal r th.il oty, 51 nW db.: 'oy it iTESitars Ef our one . ICE: Try to keep be bO n ed at the we and al in. moll ro keep wale l dwers, mating sure Blass laxly me In- P 'a tl nti nlr 111. •'• 1I r oft, I, h r' SP ,Ct ktl nCI r i1 i II `. 1.�� ( 1YVli l tt L .In, MkM1mze. Sped, paroWplha rat HIXk to dfmb iron a r Mencad. Um aalMMal well rest M PVC. • moiled aedmwiMManaheolcdeantl3uN lain BreeNbbe XANotINGiNESKYMIER:1he sNmmn6 0 is fan -.i'TI(y nr' ( '.f� t 7:dn5 doj srE'3:i. 3.� CCYt V CWI;Ar Ud nt , W.FI� i 1.. by mnd,hot auveeam In To remove `Il)rf, WBtE f.'$Ifr"rd tllA J!i 1Qtlfj... eadins 'islehandled to DO Or M 'is spent dsc . do lM hose fln1 then aianrXr MB'brel man Me Intel canrleClim. CO Or hY to auk Ma .ttheatlsMMamanoed.defthe ,dmmerlawC Hma meNwa. D S 1 , I (/` I, :: C . vAN.. team urbeel NBe Mosel mot trig' do damage on the are Do MI Opens mold BIoad ro Be P nt t NL i , .... ... _ . sommerl possible. if podde Mbng other eon'a-'9mm tma capped, Mel rho slimmer out in that Men away S_y NC, CLJS Watt+r rpt,ylfty \\1 hominnaanla roenwamme 0olemwl mra suxealul me t 1 n 3' hose - - ,1 i p>wia' ate CONCEPTUAL PLAN ONLY THIS DRAWING IS NOT A CERTIFIED SURVEY AND NO RELIANCE MAY BE PLACED IN ITS ACCURACY. THIS DRAWING HAS NOT BEEN REVIEWED BY ANY GOVERNMENTAL AGENCY FOR COMPLIANCE WITH ANY APPLICABLE LAND DEVELOPMENT OR OTHER REGULATIONS. EXISTING INFORMATION IS BASED ON CUMBERLAND COUNTY G.I.S. DATA. PRELIMINARY DO NOT USE FO CONSTRUCTIOI Know what's below. Call before you dig. s - a: z y LO O p 00 ell N z C) z °aDo M'u ° a -o oU Do i a Q I U O � -Iz 0 n O O O U rtn9 eC : CZZq CQDOa ) �ce) 0M U E12) = 00 C3 K 0 xO N SZ O J w m } z Lu a City)>, U M 1 d Z rLi E3rV,=�pJ ITJi-j (/1 �aNt�7�07't? 4, 411 THIS DRAWING IS PRELIMINARY, AND NOT FOR CONSTRUCTION, RECORDING PURPOSES OR IMPLEMENTATION. Owner: CBMMPROPERTIES LLC CONTACT.238 N. McPHERSON CHURCHRD FAYETFEWLLE, NC28303 PHONE.910-864-1125 FAX.-910-864-0938 Project: THE ESTATES OF MORGETOWN PHASE 1 0405-42-0744 tax Id #: 0405-52-1954 0405-51-2958 township: Rockfish county: Curnberland State: NC POND DETAILS CONSTRUCTION DOCUMENTS job no.: P12-096 date: 12/02/ 13 drawn by: PDM survey by: JTR checked by: JAN sheet no.: a O T 0 vD 3000 PSI CONCRETE 12"MIN. 12'MIN. FOOTING 5'x5'x1.75', RISER W1 ANTI -SEEP SCREWL 41'UG 6"INSTALL #4 REBAR ON 6" 1.75'_9 P, CENTER 4"x4"TEE IN PVC PIPE - 3" v-748 nn 4PLUG � w/2.5"0 DRII ED ANTI -FLOTATION DEVICE HOLE for Controled orifice POND RISER DETAIL DRAWDOWN ORIFICE Scale: This document provides general installation guidelines for the ArmorMaxn^ anchored reinforced vegetation system used in non-structural applications including levees, stream and river banks, and storm water channels. These non-structural applications are typically designed usingType 2 earth percussion anchors, For installation guidelines with ArmofMax"' and Type 1A and/or A earth percussion anchors used in structural appications, please contact Proper. Site Preparation / Prepare Subgrade • Grade and compact area as directed and approved by Enghmer.Subgrade shall be uniform and smooth. Remove all rooks, clods, vegetation or other objects so the installed mat will have direct contact with soil surface. • Prepare seedbed by loosening the top 2-3 in (50.75 mm) of soil. • It is suggested that a soil test he conducted to ensure soil fertility, • Incorporate amendments such as time and fereiliEer and/or wet the sail, if needed. • Do not mulch areas where mat Is to be placed. • For additional factors of safety, also seed Grotto system Installation. • Consult project plans and/orspecdeatums mrseed types and application rates. Levee Installation • Install Initial Trench mHwt Side and Protected Side of the levee - refer to Figure IA. • Onmll HPTRM up the levee and across the crest. • Install pins and earth percussion anchors based on bachi ay and spacing of tie down devices shown in Figure 2 or as designed in project spre frcatleve/drawings. Figure 3 details procedure for installation of earth percussion anchors. • Install Longitudinal Edge Trench on the unit and last mil of the pmdect - rater to Figure 4. • For levee slopes longer than 45 it(13.7 me, install modified check slots- offer to Figure 5. Note: All seam manors shall be a minimum of 6 in (150 mm). For end or roll overlaps see detail in Figure 7. S .+.F �" I THE ADVANTAGE CREATORS" GEOSYNTHETICS ALTERNATIVE OPTION TO 15" CLAY LINER II IL. IJ VL/-lI L11 N"I\ IVSr 1 UL 1\LI V I r COMBINATION OF b" CLAY LINER AND BROADCAST BENTONITE PELLETS APPLIED AT A RATE OF 2 LB/SF FOR THE ENTIRE SURFACE AREA OF THE POND. CLAY LINER SHALL BE COMPACTED SUCH THAT THE INFILTRATION RATE IS NO MORE THAN 0.01 IN/HR AND SHALL BE TESTED BY A GEOTECHNICAL ENGINEER TO VERIFY THAT THE COEFFICIENT OF PERMEABILITY MEETS OR EXCEEDS REQUIREMENTS. RESULTS SHALL BE GIVEN TO SITE ENGINEER OF RECORD. ,•" Teeth e,w .e n r Figure 4 - INITIAL TRENCH DETAIL ..."L........... v v . . . . . r........ �..�.. �.. SEE SHEET C20 FOR SKIMMER DETAILS Scale: Not to Scale Calculate Skimmer Size Basin Volume in Cubic Feet 26,352 Cu.Ft Skimmer Size 3 Inch Days to Drain" 3.00 Days Orifice Radius 1.4 Inch[es] Orifice Diameter 2.8 Inch[es] *In NC assume 3 days to drain PPI � sum wtI- IR E A ., e .F .Ss•f .-(a aln.laeR"' 1 I f •I 4 t ' f x x x .� - x . x •II K : x PINDEAIL FAOrN . x •I , . , . . . x PEPCUSSION I cro.I.-PORP Figure 5 - PIN AND ANCHOR PATTERN DETAIL Not¢: ore ooellar patmm shmm (etldeU & 08 end o3/SY) ones nal InHmb anchors lOr Venclles, evtl of roll uvedaps, and IPudinea dudsbts. I� InNersion Red removal L.atllock,ng Tyma 2 Are"r only Figure 5 - EARTH PERCUSSION ANCHOR INSTALLATION 157.0 r __ _ _____ _-_.---- ---- 156.0 -__ _ __._ _--.__ -_---- 155.0 __ --s____ ____ _--- 153.0 -------- - -- \-- ----- 151.0 .-------- ----- - --- - -- Herne �r /{ --. ----- ---149.0 PPE-146.0 '.._______- ---- - - - --- - - 47.0 --- 146.0iL---- - - - - ---- --- -------------' - 145.0 'i` --------------------------- "--------- 144.0 '.--------- ---- - - -- -----_ -_ -- 143.0 r --- 140.0 ------- - --- - -' ---- - --- - ----' -' 130.0 L --------------------------------------- / s cml, ola t palnsl e XPTRM Type Dae1 Armor Only Another Note, Trim excess tendon after vac eeg orate. WEIiiARMORING DETAIL Scale: NTS Figure 7- LONGITUDINAL EDGE TRENCH me-e. s.0ae UPTcaL Figure 9 - TERMINAL TRENCH Figure S - MODIFIED CHECK SLOT ANCHORS f� ,u.INu Ina r:R4ceE_ OVERIAPPINGEGG FLOW COVERED EDGC i iAPLE-� ��L / F HPTR1.1 L Min 300 mm (t m ITypl HPTRM END OF ROLL OVERLAP IONT Figure 10 - END OF ROLL OVERLAP DETAIL THE ADVANTAGE CREATOReI' 1'RI'E% rN1LEX 1.800.667,4811 GEOSYNTHETICS IP EL-15200 SEDIMENT STORAGE BMP-21NSET Scale: _ SHALLOW LAND COMMUNITY '(EL. 148.00 to 148.50)= 3848iS.F. 1PLANT/4S.F.24"O.C.= 962 PLANTS PLANTTYPE QTY BOTANICALNAME COMMONNAME ROOT CAUPER HEIGHT NOTES HERBACEOUS 301 Ascle ias incarnata Swamp Milkweed CONT. 4" Pot 24" O.C. 301 Carex Tenera Quill Sed a CONT. 4" Pot 24" O.C. 301 Lobelia cardinalis Cardinal Flower CONT. 4"Pot 24"O.C. SHRUBS 20 Aroniaarbutifolia Red Chokeberry CONT. 3Gal. IW-2N" 24a'O.C. 20 Ce halanthusoccidentalis Buttonbush CONT. 3Gal. 18"-24" 24"O.C. 19 Ilex glabra linkberry CONT. 1 3Gal. 1 18"-24" 124PO.C. NOTE: ONLY HERBACEOUS SPECIES SHALL BE LOCATED ON FOREBAY BERM I SHALLOW WATER COMMUNITY EL. 147.50 to 148.00 = 3688 S.F. 1 PLANT/ 4S.F. 24" O.C. = 922 PLANTS PLANTTYPE CITY BOTANICALNAME COMMON NAME ROOT CALIPER HEIGHT NOTES HERBACEOUS 196 Iris Vir inica Blue Flag Iris CONT. 4" Pot 24" O.C. 273 Juncus effusus Soft Rush CONT. 4" Pot 2411 O.C. 273 Pontedaria cordata Pickerelweed CONT. 4" Pot 24" O.C. 90 Saururus cemblus Lizard's tail CONT. 4" Pot 24" O.C. 90 Schoenoplectustabernaemontani lSoftstem Bulrush I CONT. 4" Pot 24" O.C. CONCEPTUAL PLAN ONLY THIS DRAWING IS NOT A CERTIFIED SURVEY AND NO RELIANCE MAY BE PLACED IN ITS ACCURACY. THIS DRAWING HAS NOT BEEN REVIEWED BY ANY GOVERNMENTAL AGENCY FOR COMPLIANCE WITH ANY APPLICABLE LAND DEVELOPMENT OR OTHER REGULATIONS. EXISTING INFORMATION IS BASED ON CUMBERLAND COUNTY G.I.S. DATA. WETLAND PLANTING SCHEDULE SHALLOW WATER COMMUNITY SHALLOW LAND COMMUNITY %pyrcl e,3 7,Drr^,v at r r "rot C Lvr,ents .On51rurt aCCOr T N tl'. l IESP .i ifinie.nts ev s ,quires '1P st rmwa P «nit 1 h aniline 1beS tegi r n �Ie St a _I Lf z signer InspeC', cwr, rq con<_Ir., barn C rut. o-Irity with Ti Glans erg EE enC er'v asrnn4pr� wiUt thF ilvat ES '1 AU AC2r­, .f- I[^)f Vvate` 000lrty PRELIMINARY DO NOT USE FOR CONSTRUCTION Know what's below. Call before you dig. 157.0 ,58.0 155.0 154.0 53.0 152.0 51.0 ,50.0 49.0 148.0 47.0 146.0 145.0 144.0 143.0 142.0 141.0 140.0 139.0 d h r C3 1N OC NM0 N a o0 C a .O N 0 O n Cf O 00 00 y�°�U- Qai I P Z O N O ^ O O CO M Ill c'I N-0 a C Y _ 00 U CI > O O CD E- aED C) o M 12 d d Z ' .a......r a!, - SEAL 031459 = y ,r t GS-I5-1 4 c to THIS DRAWING IS PRELIMINARY, AND NOT FOR CONSTRUCTION, RECORDING PURPOSES OR IMPLEMENTATION. >_ Owner: CBMMPROPERTIES LLC CONTACT.' 238 N. McPHERSON CHVRCHRD FAYE7TEVILLE, NC 28303 PHONE:910-864-1125 FAX..910-864-0938 Project: THE ESTATES j OF JEORGETOWIN PHASE 1 0405-42-0744 tax id #: 8405-52-1954 405-51-2958 township: Rockfish county: Cumberland state: NC STORMWATER MANAGMENT DETAILS BMP-2 CONSTRUCTION DOCUMENTS job no.: P12-096 date: 12/02/ 13 drawn by: PDM survey by: JTR checked by: JAN sheet no.: C17 3000 PSI CONCRETE 12"MIN. 12"MIN. FOOTING 6.25'x8.25'x3', RISER W/ ANTI -SEEP SCREW COLAR 3, 6"INSTALL #4 REBAR ON 6" CENTER 4"x 3" 4"PVC B. 5 x8.25 w/2.5"0HOF 01 ANTI -FLOTATION DEVICE controled ` POND RISER DETAIL scale: ALTERNATIVE OPTION TO 15 CLAY LINER THE 15" CLAY LINER MAY BE REPLACED BY A COMBINATION OF 6" CLAY LINER AND BROADCAST BENTONITE PELLETS APPLIED AT A RATE OF 2 LB/SF FOR THE ENTIRE SURFACE AREA OF THE POND. CLAY LINER SHALL BE COMPACTED SUCH THAT THE INFILTRATION RATE IS NO MORE THAN 0.01 IN/HR AND SHALL BE TESTED BY A GEOTECHNICAL ENGINEER TO VERIFY THAT THE COEFFICIENT OF PERMEABILITY MEETS OR EXCEEDS REQUIREMENTS. RESULTS SHALL BE GIVEN TO SITE ENGINEER OF RECORD. 4" PVC PIPE INV-159. On DRAWDOWN ORIFICE SKIMMER CONNECTION DETAILS Scale: o o ca e Calculate Skimmer Size Basin Volume in Cubic Feet 37,800 Cu.Ft Days to Drain' 3.00 Days In NC assume 3 days to drain Skimmer Size Orifice Radius Orifice Diameter 4 Inch 1.6 Inch[es] 3.2Inch[es] BMP-3 INSET Scale: _ CONCEPTUAL PLAN ONLY THIS DRAWING IS NOT A CERTIFIED SURVEY AND NO RELIANCE MAY BE PLACED IN ITS ACCURACY. THIS DRAWING HAS NOT BEEN REVIEWED BY ANY GOVERNMENTAL AGENCY FOR COMPLIANCE WITH ANY APPLICABLE LAND DEVELOPMENT OR OTHER REGULATIONS. EXISTING INFORMATION IS BASED ON CUMBERLAND COUNTY G.I.S. DATA. WETLAND PLANTING SCHEDULE SHALLOW WATER COMMUNITY SHALLOW LAND COMMUNITY PRELIMINARY DO NOT USE FOR CONSTRUCTION %pp;dued ,ipmtwat=zr p,,--mit Documents •,:onstruct!or in accordan-e will, ., iese documents iv requlreo Ly toe stormwater permit. North Garolina r Ales reo-tre that the St, rmwa:..r syste_, designer Inspect durinc, corlstrIc "ion certify conformity with the plans and spc"; ;or certify compliance with the /ir,,,ater rujes.'' ANCAC2u 1008011 .� Pe•�,. Ldate _ NC G..I„rn of .'Oaty C„61tly ;.r2c' , ___ _ Revisl". Gale- - -- Know what's below. Call before you dig. F116667. - - ----- ---- --- _- ______- -_ _ .------- __.-..__.____ ______. _.._-_ _. ____ ___._- -_. _..__. ___________ _.._. _. .__..___..__ ___.-_________..-_.. ___.---- ---_____.. __- -_... __....... __- - __ _-___. --_ - --- - _ - - - - _ ---- ---_ - ____ __ -___ --__ - _ _- __ _________ -_____ __ - - - _- _- --- _ __ __________- 68.0 - - ------ ------ - ---- --------------- -- _- - _ ._-._-__..________. _. -.. _ _____.-.__.____.. __--__-_-_--_____-.______.---- - ----- - _ - - - ------- - ----_--_---------_-------------.----.- ..---------'- - - --- - ---- ---- ---- __._ __a 166.0 ___.__________.. _.__ __ ------------------ --________.. _.-. .. __. _ _ -- _.__-______.... -------- __---------------- --------_.-----------. _- _ - - _- - __--__-_------------------- --_- - - ---- 5.0 _. -- -_ - _-_ TOP EL.-164.00 -. -_ _. _ _ -. ___ _-_._.._. __. ____. _.._ _____ __ _ _________ ________ ______ ___ _______- _______ -_ - -_ - _- ___ T P 0__________ ______-____-__-- __..__- _ -- EL.-- ____ 184.0 -__ ____-_-_ _- _-__EL.- 163.2T __- ___ 83.0 -- - --- -- ---- --- - i + 182.0 --------------------------- - - _ _____ _________ 1 tYR STORM EL 162.60 -_-_-_ --- ..__-______ ________ _.________ ._______ _- ______ - _______ ___- - -_ _- ______ - - _____ _________ __ - _- _ _- - ____ _____ ___ ____ ------- ___ _____ _____ __- - _- _____ 162.0 161.0 �_____ _ _ _ _ __ ____ ___ 6110 _ 159.00 SHELF (101, 1 PPE-159-0 �______ __________ _ ___ __.- - _ ______- ______________- _ - - - __ - __- - _- _- __________- __- _ ATEO - - ____ __-__-----___- _- ____- - _-________ --- -_______-___________-_-_________________- - _- - ______ 0 LF 10.1 / 10'TOPS01L( ' 156.0 r___ ____ ___- ____ - __ ____ ___ __ __ __ _ _ _____ __ _ - - _- _____-_______.____- -------------- ____ ______-_______- _- _- - - _- _ _. - �t _ _____ - - _- ____-___- ________________- _- - - - _____.._-____ _ - ____________.___ _-_______- _- _ ___ _____- - _ ___ _- - __ - - - ______ - - - __- - __________________ - __ 159 '-----"'"--- �f ' '/� / 1 ----- �/ /--- ---- ---- - -- --- ------ --Y ------- - ------ ---------- ---- - ---- meµ" f - / �j /� i , 157.0 156.0 _- __ _-___ _- __ - ___ _- - - - __ f / __ /---f - - __,n f/ _f/ _ _ _ _____ ____________ - _...._______. ____--__.- _ _ -- �� YC/ / __ E T T RA - 1 ____ f� '�_ -f --- - N ---- _ -- ----- --- ---_ --- ----_ - - _ - _ - __- - _ - - ---�--------_ - -�ii 156.0 >5, SEDIMENT STORAGE ELAM 00 158.0 i`-_--_____ __ _____ _-______ - _____- - - __ ___-_ __ __- _- _ _ _ � � Ey - � �15-C� _--____ . _____ _ __- _ _- _ _ __ Nf/gf - 1d,.P- _- - _ _ _____ ----------------- _- ___ _- _-__-_ _ -_ - - _________ _-ai 156.0 a m<i BOTTOM EL: ___--__________________________________________ W ___ - _________-__________-____-_____-___-____________________________________-_-___-_______� - - 1550 - -- - --a ____-- ��P �fl �� /�f%�f/ / /� / //� --_ _ 155.0 N J / J 154.0 F - J _ - / f - 154.0 W W N W 2 1530 i`--- ------ -- ---.----- --- ----- - -- -- --------- "--- - -- -- -- --- W- -- - -- --"-- -----------N ---- ---- .__----..._ --- ----- --- -- ---------------------- -- --- - -- --------------- ----' __---------- ---- -- - - --- ---" _----- -_-- - -- --- ---' ----- - - - -- - -- --- ----- - - --- ---------- w- - - - ---------------------------- ----- - -- - - ------ - - 153.0 152.0 ---- -----------------'-' --- -- ---------- -- - -- --------- -- --" --y------ -- -- ---- - ----- - _.---..._ __..._-_--____. -___. _. .. ----- ---__..-- -- _. _.._. _------- ---------- .__ _.___ _- _. _- ---- --- - --- - - ----m----- ---- ---- - - ---- -- i 152.0 w > 151.0 -----_ _____ ___ ___ _____ ____ _ __ _________ _ _ _ _ _ ____ _ __ _ w- __..___ __- _- - _ -__ __.._ _______ _- ____..__________ _--------- _-__-------. __-----. ___ _.. __._--------__ _._..__ _ __ _______ __- __- - - __-... __ --- -___-____.---------_ _________ __- O_- - _________ ___- _- _ 1- ____ _-__ ____ - - _ _- - _____ _____ - - _ ___i 151.0 > o k 150.0 `----------- - ------ - - --- -- -------- - - -- - ------- -- - - - ------ --- " -- ---- ----------o -- -_---- --------------___--------- ---- ---------- _ ---. __- _.-------- -_--- -- -- - _..----- - --- - - --.._._.-. _.._------- ------''--` --------- - - m- --- --- - - - ---- ---- ---- - - -------- - ------ -_ J 150.0 h m 00000, z N 0 to o p 00 O z O �V z t7,U rn 0000 W G y O oU`o >Q N 'c0 o ad : � 0 O O U co O � aj cl� a)-M t7 z >< LO 2 = C0 _1 0 x O ' W N `c �[ O �..-p -I Z vCo oM T�� W J L M O d ZEi " it l° 10. 9 n SEAL = ' 031459 = h c T.t� nmu umlm`o``��`. THIS DRAWING IS PRELIMINARY, AND NOT FOR CONSTRUCTION, RECORDING PURPOSES OR IMPLEMENTATION. 0 .N m B, 0 0 0 Z Owner: CBMMPROPERTIES LLC CONTACT.' 238 N. McPHERSON CHURCHRD FAYETTEVILLE, NC28303 PHONE:910-864-1125 FAX.'910-864-0938 Project: THE ESTATES OF GEORGETOWN PHASE 1 0405-42-0744 tax id 111: 0405-52-1954 0405-51-2958 township: Rockfish county: Cumbeltalld state: NC STORMWATER MANAGMENT DETAILS BMP-3 CONSTRUCTION DOCUMENTS no.: t P12-09 6 date: 12/02/ 13 drawn by: PDM survey by: JTR checked by: JAN sheet no.: C18 Q d QI N CN Lo STANDARD BRICK CATCH BASIN (15" THRU 54" PIPE) STANDARD BRICK CATCH BASIN w" THRU 54" PIPE) o M (N.T.S.) --- -- N (D 04 (h BACK OF CURB S�iEP 840.66 CONCEPTUAL PLAN ONLY 3.5 - - _ X 3• 4 BARS 6 pa BARS ACa. EQUALLY SPACED e° A� a STD. s' THIS DRAWING IS NOT A CERTIFIED SURVEY AND -- O n 9TP,CAL Ba' BOT3.-BAa cuEm t/z• R 1 r _ 1YPTCAI, a4• EA6iCLL clr,m 6• rrr,reT. a4• ePnt-Orr cu® r tr R S 11, 1/2' Rya LL 5.VAR. °o e e M+ ,N.i 4 0,• MIN. Y A Y '° E a C - E P It 840.66 G + NO RELIANCE MAYBE PLACED IN ITS ACCURACY. THIS DRAWING HAS NOT BEEN REVIEWED BY ANY N o t; 2 '> -� 2 y U o Li , y Q' i + 9 3/4' n * "+ s•_o. P1ea o Rao. m 8" D = _ 8• D GOVERNMENTAL AGENCY FOR COMPLIANCE WITH ANY APPLICABLE LAND DEVELOPMENT OR OTHER > C Q c t o O O Z M U � " 61R5' .zr fr S CURB AND CUTTER - x - REGULATIONS. EXISTING INFORMATION IS BASED � C N a,a PLAN OF TOP STAB WITH CATCH BASIN ON STEEP GRADES , .., .; Y;...:. .A r\ O M O xm AB mr1�IE r END ELEVATION , . ...... . ,_ •ELEVATION •` ON CUMBERLAND COUNTY G.I.S. DATA. _O C L6 2)M = Db J ro mwcE ro xcwFsr tAte• - Nla USE ON FLAT GRADES b 2% AND UNDER ���� _I '� .� u WHERE 30' TO 76' PIPE IS USED. SECTION JJ SIDE WHERE _ ,� X O 1 Y C) N m O ��� _?4' E - - 42' TO 54' PIPE 6 USED. SECTION - MM W Z < t _ M L,I_ 'U'lY• /T Sy4 3 _0 ,_O• 'ol Z a O M T` U A BARS DEPRESSED 84 BAR GUTTER LINE a 8' E PRELIMINARY U3 J d M COL d Z SECTION - RR bELEYATIO � MEDAN Z NORM4L CURB AND GUTTER ON OGHI GRADES PA0 '[rP3cel sa' vJBmceD cu® 7YPICM. so' Ro1L CURB N 4 BARS 'U° HORRID GUTTER NE LAYOUT USE OONOGRADE :::!: :1.,. •,. QDTET�DO J "13 J NOT USE FOR A t W-j s•R a/a, 3, v \ 3 vz EQUALLY SPACED 7• USE ON SAG VER CAL USE ON GRADS 2X ANO OVEB _ - CATCH BASIN INSTALLATION IN MEDIAN WHERE 8'X6' CURB IS USED 6 (NOT TO BE USED ON FEDERAL -AID PROJECT) SECTION - YY " M CONSTRUCTION _ DUMMY GROOVE JOINTS EVERY 10' _ c. N RF RAI NOTF¢; �' a2s E _ At IXPANSION JOINTS EVERT 10' ' l I FH FRPd1E GRATE, & HOOD MORTAR JOINTS 1/2' 1/8• THICK STD. 840.038 NAA,ppllnnnlq,A4A ON Aii •+ ELEVATION 3000 P.S.I. CONCRETE TO BE USED. SECTION - SS NORMAL CURB AND GUTTER ON STEEP GRADES •CONCRETE TO BE PAID FOR AS BRICK MASONRY THE POURING OF FLOOR SLAB TO BE ACCOMPLISHED BY FORMING. � P1Ad MI lAa O OIIENSON6 AND 01AWOnES FOR HICK CDEPT 11 Tr JIT ATCH BASTx ALL CATCH BASINS OVER 3'-6' IN DEPTH SHALL BE PROVIDED O 30' I F!,A�ENGNEEANG & INDUWRUCIURE DD'T pNENSmXs OF 80% END PPE LCWR RBNFORCIXC • WBC YAPo6 OF HeCK MASON El%ICIpNS ENCINFTRNG A WFlWTRUCIHF WITH STEPS 1' -2' ON CENTERS. B DBAIWiRNG & INFlUSTMICRIAE OFPT %•'<�'•y D• CML ENGINEERING DMSION NIFIBBI _ IN X HE PIPE CML OIGINERYNG ORISON USE TYPE 'E', 'F', & 'G' GRATE UNLESS OTHERWISE INDICATED. 8' 8' DIAL ENGINEERING DIVISION 4J3 IMY 5T. 28307 D A e c c CAI. tap a . Tm BR rolEwvcE ro _ _ _ 4ll NAY Sf. 2&101 i 417 HAY Sr. 28301 xFAPOT ,/1e• (910) 433-1656 ,e - - - 3-3 K --t.a5 nBO.E D.ouz(910)433-165fiJUMBOBRICKWILLBEPERMITTED.CONCRETEBRICKOR4'SOLID(910)433-165624"30"----MN.N�CONCRETEBLOCKSMAYBEUSEDMLIEUOFCLAYBRICKSCURB DETAILS 3e•ai si1-�a-a 3eaniIsmigszDa2tozffiADOPTED FROM NCDOT MGHT USE 12HWALL?OR6LESS0USE�MTOPOFW�B' WALL,ADOPTED FROM NCDOT STANDARD N0. 840.01 FOR THE REMAINING 6' -0'. •.��•"1. STANDARD N0. 840.01 2 OF 2 INVERTS SHALL BE SWIPED 70 FORM A SMOOTH, REGULAR SURFACE, SECTION -X% PAGE 1 OFF N0. 840.01 Al AX A \\ SD- 1 DATE 3/I1/2008 DRAWN BY C.W. N0. 840.01 DATE 3/18/2008 DRAWN BY C.W. SLOPED TO PREVENT SEDIMENTATION. DATE 3/18/2008 DRAWN 6T C.W. q11111111111Y, CAD FILE : 24_30curb SCALE N.T.S. CKb BY C.A. CAD FILE : STOBRC82 DR-3. 1 SCALE N.T.S. CNb BY CA DR-3 CAD FILE : STDBRKCB SCALE N.T.S. CK'0 BY CA 6'-0' W4 BAR '6" BN5 0 tlt'IS. 3' G IS PRELIMINARYTHIS , AND NOT FOR CONSTRUCTION, 2prM iB � A= .ICIM 'q x x GENERAL NOTES: RECORDING PURPOSES STANDARD OR JUMBO BRICK SHALL BE USED FOR WALL CONSTRUCTION. OR IMPLEMENTATION. SOLID CONCRETE BRICK OR BLOCK ARE OPTIONAL WALL CONSTRUCTION BILL OF MATERIALS R/w 6" MATERIAL. N/C n n A B 5 ' U 9.] SECTION X-X DOWEL C aP DN PRECAST UNITS MADE OF CLASS "AA' CONCRETE MAY BE USED IN LIEU OF BRICK MASONRY CONSTRUCTION. DESIGN OF PRECAST UNITS SHALL c z6 ♦ +'-6' 26.1 wlWs (WITHOUT TOP) FORR GP EKT � n BE SUBMITTED FOR APPROVAL PRIOR TO CONSTRUCTION. T 14 s IN 3 8 10.5 STEEL NMRNVRNN STEEL TOTAL WEIGHT 217.6 SEE STANDARD &OS4 5•_y76• 6-0• W. YDS CIA£S 'M• CONC. 2.6 uwEs (4a'-Eo' BODnuJc) FOR "HOLE CJkR h FlUNE e ALL ADJUSTMENTS TO WALLS, SLABS OR REINFORCING MATERIAL SHALL W. ros. eRIC FT. rR. a am TRIO( MAY BE USED TO PLAN OF TOP SLAB BE INCLUDED IN THE UNIT PRICE BID FOR EACH UNIT. W. MS. BRIG Fr, a 12 0.e4 grGRADE ADJUST FRWE & CWEB 7• 'NH1JS 7- A•D\ R TO SURFACE EU MMN. MAX, t' NOON HOCK S• Y BAPS W It}' CIS fi' n CRLss BOOK NCRETE Top Sue --1 OPTIONAL MANHOLE SHALL BE INSTALLED IN POSITION AS DIRECTED BY .�� _ 'a'H4a THE ENGINEER. ALL REBAR CROSSING THIS OPENING SHALL BE CIJT OR "Y" BARS BENT TO ALLOW 2" MINIMUM CONCRETE COVERAGE. THE OPENING SHALL NOTE 1: SECTION •B" OF THE PROPOSED WALL SHALL BE 8" THICK. ..,r BE ENCLOSED WITH 8 'A• BARS TIED TO THE REBAR MAT AND SET SO A SECTION 'A' SHALL BE 12' THICK, L T. BAR DIMENSIONS ARE OUT TO OUT MINIMUM OF A 3" CONCRETE COVERAGE IS OBTAINED. REFERENCE STD, NO. 840.54 FOR ALL MANHOLE INFORMATION. NOTE 2: IF PROPOSED STRUCTURE EXCEEDS 12'-0" VERTICAL HEIGHT A DESIGN WILL BE REQUIRED FOR APPROVAL i \ JUNCTION BOXES OVER 3'-6" IN DEPTH WITH MANHOLES SHALL REQUIRE c STEPS TO BE PLACED ON 1'-2' CENTERS. REFERENCE STD. N0. a40.66. NOTE 3: ALL REINFORCING STEEL SHALL BE SINGLE HAT; O NOTED: �" - SEEPS - SEE 6 8' } 4'-RESIDENML GENERAL NarEs OF HOOK DOUBLE MAT STEEL MAY BE USED IN LIEU :; 5'=RESIDENTIAL COLLECTOR � � 12, � � DOWEL '",° BARS SHALL BE SPACED AT A MINIMUM OF 12' CENTERS. OF HOOK BARS IN BASE SLAB. 8'=MOROVGHFPRE9 ! WM011LL1'A o wNo¢Rve L� %� MR s'-e' MAXIMUM DEPTH Of THIS UNIT AS SHOWN IS 12'. Of OK91431-,q SEE IN1'A' OTPIC., OpET'• wRLr \ 1r / PLAN OF BASE SLAB ItIDKNATd BKaaon AT BACK OP CUBE 0i / • EXGNBTEMG k INFPASTRWT111E • h INFRSHUCBfEOEM ��� WE 1/"13 GRAN Sr N lM FNd1EFPoJG DA'BON W0. EN4IIIEDBIC ORISON N 433 RIOT 51. 28mt /1S FNY TT. 2B3Dt cn HIS : IYPSAI3C SCNE NTs aco e, CA INSET NA" (s1o) 431-1656 (910) 431-1656 0 CONCRETE BLOCK STANDARD TRAFFIC BEARING STANDARD TRAFFIC BEARING Y&RS B 104• ]UNCTION BOX JUNCTION BOX CONCRETE BASE Sue N.T.S. Se" AND UNDER PIPES 36" AND UNDER PIPES SECTION X-X PAGE1 OF NCDOT STANDARD N 840.34 PAGE2 Opt NCDOT STANDARD / 840.34 p (WITH TOP) DR-6 DATE 3/18/2008 DRAWN Elf CSA DATE 3/18/2008 DIMWN BY CSA Z CAD FILE : SIOJH RWWAC SGYE N.TS. CK'D 8Y JPB CAD FILE : STOJBTIWFFIC DR-6. 1 SCNE NT.S CK'D Hf ,PB E L-E -1 Owner: VARIES r . r °Pmx,L 11'e°'E I I Q mmw. xwH� G < PUTLU IENDNNL DIUDOarIs Y 1 W . . +' CBMM PROPERTIES LLC NOTES: • PIPE roR :R PIKE N awns ,/2. a g THkX REE % % DM D A U. DMSED 1MA5 stW S m mnm. ALL B151N5 OVER 3'-6' 4m ND, E W, w H, H Hr D E , W. `ems DEPTH SHALL BE PROVIDED A A O >Tlia 0R 1 Y-z• s=Y t'a' 3'-1• it t'-Y 1'-9' 4r 16m Bm a ROiaff USFD Em nC wsRA.T1m a WITH STEPS 1'-2. O.C. 9' 1 1Y 21• J'-Y W-I' i'-9' Y-Y 12' 1'-8' 2'-31 49 21m = V JHBo BeOt K6L H PODIITINa m11DE2 Wx m e 1•,24' 33' 4'-Y Y-z' 2'-9' 4'-3' 12' I' -JD' 2'-9' 44 2830 SWW CBID6IE lDO6 iW H USp N uu m 41A1' 6WOL PIPE Y 39' 4'_ e'-4' Y-r 4'-9' 12' 2'-2' 3'-Y 4S RIX RN rd N NOON m TER TIE r NUL =ed N EXPOSED CONCRETE CORNERS = INLET H1Nf, us: It 1XLL TO rd BCE, nP m KAll, MB r WW1 f/ �I( M' AB' 5'-B' 0'-t 0'3'-3' S'-9' 12' 2'-11' 4'-4' 4S 5�0 x. C Ron TK BLM1,6 Wd. WFlBTa Nm ,KM1JI11610H SHALL BE CHAMFERED 1' E m • e./ W: �\ b Y r 'A\ fff •Ih• 6•,w 6'-Y t7-6' 3'-h' C-6' 1z' ]'-4' S'-Y 4s ]sm r �.4. w.mm Accawxax. COtVTACT.' MOTAR JOINTS SHAWL BE PLAN 1/2' t i 8' PLAN BALL SECTION 'A0• rA+ r-9• 1Y�' 4'-s' e'-0• 2r Y-4• 7'-5• SO ITODO 9a suTBvm LION i r F lmlwlaa mKmTe pAE a sn W W" zA' m IiDI, 238 N McPHERSON CHURCHRD / / M 91' r-9' fY-4' 4'-5' 9'-0' RY 3'-4' 7'-5' SO 10000 wwdE mw t. C. Am ro AH4.G 91mAll m SW1Mm X0. 6Ma06 '. ! mxC aecx wY s lmD m ADA6T nW6! ICN -.. AL NNmm eons 01FA Yd x HPDI 9WL E N9AGFo W, D EDWIF41 wsN sRPs ,'-r ax Mn1N6. srNPs WwL a Ix AWE' FAYETTEV/I.LE, NC28303 ALL EXPOSED JOINTS SK41L •T g I- --I wx r .. -� wnt su xD elaea BE CONCAVE TOOLED 6• DEWEY BROS. PUN E E I ' O ixauoi ADIXnmm PHONE:910-864-1125 :o GENERAL NOTES: FAX.910-864-0938 CH d. - SECTION 1m m xiarm�anramn Try TmOi'Ws.•aAOj SECTION B-B OR APPROVED F 1. Au OWCRER ro H 4000 PB Mx. C-C OR D-D JUMBO BRICK, PRECAST CONCRETE, EQUAL " 2. ImruaROMExr sIu sxru CASE! ASTr4 fits B+rBE w wTRJ Y Wn + n4 9AR o K ADIVION BOXES AND/OR PRECAST SEGMENTAL CONCRETE OEARExL£ . a f - HM'S OF BOX E HPE N]NFIXICEIEM OAR CUBG TM05 D RIPE W FOR ONE Project: BLOCKS MAY BE USED TO HEIGHT O CONSTRUCT 3. O Al GOOSED DSES 3/4•, mnn p.c EVE sEm NORM Now Hza DIMEN90N5 was eRm MA90NRr RpE a. 'ros. BASIN, BASIN 12' IN HEIGHT OR MORE _ 4. PRECAST HENWNL UNIT SHRL H CARE IUY rwn"xm m THE BASE k MN. wAu SHALL HAVE A 12' WALL BEGINNING 6'-0' PREPARED MUNOATKN AND KFE INSTmED ROD HEIDNWL OR HA[Ai u _ ' DOWEL D I A 1 B H NO. I UNCN E F cG+ER NEKRIr n. Nr. cs R.0 FROM TOP OF WALL AND B" WALL FOR THE00 SUD O RK AND CKNED FOR AUQNK . . . e _Z 5' 2'-0 Y O' 2'-fi' 12 3'_t 3'-4' 3'� a412 0.657 ase3 aw, a M] THE ESTATES REMAINING 6'-0' TO TOP OF WALL o -L 5' RPE 5wu H mo31m Hrto � w� cE,ExnNWs A , e• IV 2'-1. 2'-A• z'-V 14 S-5• Y-8• 3--9• OAST U14 DB K 0.014 0.05 A x EW caxla4naR. I30xDNC AGENT uAr O usrD r IEOD. 6. ONE SIWL BE TWe,J WRHW B.G`DLJ, Wm mIFIGRON M PREWNT '' • 24. 3'-0' 3'-0' Y-3• 16 4'-1• 4'-e 4'-4• 0.695 1.178 0.362 0.0]8 0.113 LWU4E AND MMNAW ALI041ENT. MNOR DNNlE TO TIE OF MY H REP, SECTION X-X 30' V-r Y-4. T-9• 16 V-5- 4'-8• 4'-8' OA7 1.481 0395 0.122 0.170 BY COODUCIOR WHEN PDBHTEO B! ENCPEm. OF MIN DIMENSIONS FOR DROP INLET W' I --{ 6' 3a• 4'-0' 4'-0' 4'-Y zD s'-t' S'-4' S'-4' 1.053 1.959 0.461 0.1)6 az3e ]. RIINfORGF1IFAT VIREs WIM SIZE OF UNR. NWNvm MDAM DiM'S OF BOX &PIPE REINFORCING COVER rm IIYA1]F mix mcN NAY R[ usn ro 4z' 4'-0' 4'-8' 4'-9• z2 5'-9' e'-0' e'-0' tm 2503 Osz] 0.240 a3z3 B. WROUS WE SIZE AND SHAPES AVNLAHE BY VELA. MR FRONT ELEV. SIDE ELEV. °' ANINTMWIE[mu /B'S'-4'S'-4' S'-3' 26 6•-s• 6-e• 6'-e' 1.fi46 2a+o osfio o.3t3 0.422 GEORGETOWN PIPE SPAN WIDTH HEIGHT BARS-X BARS-Y TOTAL DIMENSION ''4 . 9. Al oEMNsoxA ARE xullxu. ro RR/2 DMim D A B H MIN NO LENGTH 0 LENGTH LBS. F G '-e W-9' m * F10" 2.272 3502 GM 0.386 GNO SECTION A -A • w• 6'-e• 6-C 6'-Y 30 Ya• -fo 7-m' 2.624 4.113 DMEI 0.4e9 a6Bo 15' 3'-6' 2'-3' Z'-T 2 3'-4' 7 4'-T 26 10.3'-0' ,Ogg: 7o v�6 �� 66• T-i• ]'-+' 6A' 32 e'-7 b'-s' e'-5' z.624 4.na o.]DB 0.591 D.]99 PHASE 1 10" 4'-0' 2'-8' 2'-11' 2 S-9' 8 5'-i• i3 5'-4' 4'-0' FOR USE N� 24' 4'-0' Y-8' 3'-5' 2 3'-9' 8 5'-1' 33 5'-4' 4'-0° DI NON -TRAFFIC D+ "Lw k MwTRlC1UPE Ex6nHRxc h IIBPASIHICRgE DEM 30' 4'-O' Y-C 3'-IF 2 4'-T 9 5'-Y J7 5'-4• '-10 AREAS ONLY. cmL ExONEFAIxc HNOm r-- 'F- - .RNc t :. r.•. ENC4fmJNC h IrRaTRIK1uE 43J INr sr. 21001 433 PAT SE, R' 1 38" 4'-0' S-8" 4'-6' 2 4'-T 9 5'-1' 37 5'-4' '-10 1 )T433-SL i6w �- _� PAM (910) 433-t65G a (910) 43J-I656 42' 4'-0" 3'-6. 4'-11• 2 4'-T 9 5'-1' 37 5'-4' '-10 DROP INLET WITH GRATE PRECAST CONCRETE ANDARD BRICK JUNCTION BOX 48' 4'-6' 4'-0" 5-5" 2 5-4' 10 5-7' 45 '-10' 5'-4' (FLUSH) ADOPTED FROM -1 HEADWALL SYSTEM n ,r(OPTIONAL MANHOLE) 12"THRU 66" PIPE NCDOT STANDARD IFROM - SHELT1 OF2 NO. 840.16 SE SECTION WING & WALL SECTION 12" THRU 72" PIPE a OUTLET ELEVATION ADOPTED NO. 540.32T STANDARD DATE 3/24/2008 DRAWN BY C.W. CAD FILE: DROPNLET DR-11 �}E N. T. S. CKD BY C.A. BATE 3/24/W DRAWN BY CSA r SECTION T-Y DATE 3/18/2008 DRAWN BY C.W. CAD FILE : PRECASHW DR- SCALE N.T.S. CK'D BY JPB CAD FILE : STDJUNBX DR-5 SCALE N.T.S. CK'D BY CA. 0405-42-0744 tax id #: 0405-52-1954 g 0405-51-2958 GENERAL NOTES: SUN3 M BE MONOUT IC VARIES 1. DOURLE CATCH BASIN ONLY FOR USE ON CETY-MNNTAINED STREETS. INSTALLATION ON AND REINFOP.CING TO BE G township: Rockfish STREETS WTMN EXISTING/FUTURE NCOOF-MAINTWNED RIGHT-OF-WAY AND IN ETJ CONTINUOUS 8' Apt < OU{L E7 RECUIFES A MINIMUM OF ONE 4'-G• LONG SECTION OF RENFORCEO CONCRETE PIPE - 6' WALL 6' WALL W� NOTES' v PIPE 2. SEE ,COOT STANDARD 84G.01 FOR DETAILS BASED ON PIPE SIZE PER CROSS RIO SECTION. ALL BASINS OVER 3'-6' county: CUmbedand 3. CONSTRUCT lE SINGLE BASINS PER NCDDT STANDARD WITH WUBtE INTERIOR WALL I 4° DEPTH SHALL BE PROVIDED -• A n -' - - Y') A 4. ALL CONGRESS TO BE 3600 P.B.) COMPRIESSPJE SDPOAGTH. J-M J_M 4' a• WITH STEPS t'-2' O.C. 8' p 5. SDE Su•H SHALL BE ILUE STANDARDS 6• 6' B' state: NC & SEE CITY OF FAYETTEIALLE STANDARDS SD-4 AND SD-5 FOR PLACEMENT OF CATCH ]. PIPSECTIOND2 CONNECU4G CATCH BASKS SHALL HAVE A MINIMUM DIAMETER SAME :' - " IXPOSEO CONCRETE CORNERS = B INLET AS OF OUTLET PIPE DJ. " :` - •".'.': SHALL BE CHAMFERED 1' PIPE 40 R/W B. ALL REINFORCING STEEL SHDWN ON NCDCT STANDARDS IS TO BE PROVIDED AS I L I MOTAR JOINTS SHALL BE • MIN, CONTINUOUS MEMBERS (NO TAPS, USED AS A SINGLE CONDNUDUS BAR NJ THE SLAB) F� L 1/2• L 1/8'Iri F PUN PART SECTION PART SECTION PART SECTION PART SECTION ALL D(POSED JOINTS SHALL B 27' PVM'T 6' WALL 6' WALL WITH 4" UP 8' WALL B" WALL WITH 4' LIP BE CONCAVE TOOLED 6" FOR GRATE & FRAME - PLAN DETAILS y Y SEE STD. 840.16 -''F 3- W4 BARS SECTION B-B NCDOT ROADWAY P < NIET F OLRLET , JUMBO BRICK, PRECAST CONCRETE, STANDARD DRAWING I _ L TABLES OF QUANTITIES FOR PIPE SET IN PAD MID/OR PRECAST SEGMENTAL CONCRETE 13.5' 13.5' C.Y. QUANTITIES BLOCKS MAY BE USED TO CONSTRUCT PIPE 1'P 'YI1' i' WHEN 'L• IS A BASIN, BASIN 8-0• IN HBGHT OR MORE FRAME SIZE IS "a _ SHALL HAVE A 12" WALL BEGINNING 6'-0" 2'6'x 3'6" 2 0' PLAN te' FROM TOP OF WALL AND 8' WALL FOR THE 2 11.5' 1 1.5' 2.0 3 Wa BARS e• e' D DIM DIM DIM 12' 16' 20' W1 REMAINING 6'-0' TO TOP OF WALL a• - 1 $/O 1 SXOQe ?NEST ourJET 15' 1'-3 5/8' 0'-9 1/8• 0' 2' 0.006 0.008 0.070 A x PO 1-1/2" 9.5 SF -I I r_ .. E:...� p W o -._ I I 1/4':1' -. 1/4":1' 1 4':1' 1/4"1' - 1- 18• V-5 1 4' 0'-10 3/8" 0' 2- 0.007 0.010 0.012 A -"- 'I - - - .... '-- -- '- - - CONSTRUCTION MIN DIMENSIONS FOR DROP INLET I-, . 9" STEC TYPE "A" OR °C" ' I ' I -„--I- ? 1 $ 24• 1'-8 3/4' 1'-0 1/8• 0' J' 0.011 0.014 0.018 PART SECTION DIM'S OF BOX & PIPE REINFORCING COVER -1 I - /O DOCUMENTS 30• 2'-0 1/4' V-2 3/4' 0'-3 1/2' 0.014 0.018 0.0231 OF END ELEVATION PIPE SPAN WIDTH HEIGHT EARS-X BARS -Y TOTAL DIMENSION .I III �I 0 GENERAL NOTES:• SECTION J-J 30" TO 36" PIPE 36' 2'-3 3/4' 1'-5 3/8• 0'-4' 0.017 0.023 0.025 D A B H(MIN) 0. LENGTH 0 LENGTH LBS. F G NOTE: "-? w w THIS STANDARD SHALL BE USED WITH ALL DRAINAGE STRUCTURES • z INLET OUTLET ' 42" 2'-7 7 8' P-T 0-5 1 4' 0.025 0.030 0.038 USING REINFORCED CONCRETE PIPE SET IN EASE SLAB. 15" 3'-6' 2'-3• 2'-7" 2 3'-4' 7 4'-7• 26 '-10' 3'-T FOR USE BI SECTION A -A• w job no.: P 12-096 so;F .K; ;3•.;:.:.r , , ,; 48' 2'-10 5/8' 1'-8 3/4' 0'-5 3/4' 0.028 0.038 0.047 18" 4'-0. 2'-8' 2'-11" 2 3'-9' B 5'-1" 33 5'-$ 4'-0' NON -TRAFFIC ;o 0 OAWRRIBG h NPASPRUOURE AREAS ONLY. OUT EXCAVANG k IMeItiIRUCBWE 24' 4'-0" 2'-8' 3'-5 2 3'-9• B 5'-1• 33 5'-4' 4'-0' A IMRWBAKRIRE ENGINEERING k� / / cMt EI1Dn'RRINc DNOm 54' 3'-2 1/8' 1'-10 1/2' 0'-6 1/4' OA35 0.047 0.058 un. B40NIMG DMBm • OA DOMING ONtaox CN1L ENONEEPoNG CMSON date: 12 02 13 i SECTION Y-Y 15" to 24° 4D IMr ST. m3m 4.0 1Mr sr. 2B3pt 30' 4'-0' 3'-6' 3'-17" 2 4'-T 9 5'-1' 37 5'-4' '-10 42 NAY ST 26Wt HAY ST. 28701 (9101 4.U-1656 60' 3'-5 5 8' 2'-0 1 4' 0'-6 J 4' 0.042 0.056 0.071 (91a) /33-+656 36' d-0' 3'-6• 4'-6" 2 4'-7' 9 5'-1' 37 5'-4' '-10 (910) AJ3-1656 6) 43J-1856 drown b PDM 'O= TYPICAL 66• S-9' 2'-2 1/4' 0'-7 1/4" 0.050 0.067 0.084 CONCRETE BASE PAD y BRICK DOUBLE CATCH BASIN 42. 4'-0. S-6. 4'-11" 2 4'-T 9 5'-1' 37 5'-4• '-10 DROP INLET WrfH GRATE 15" THRU 98" PIPE 72' 4'-0 1/2' 2'-3 3/4- 0'-7 3/4' 0.059 0.078 0.098 FOR DRAINAGE STRUCTURES 48' 4'-6' 4'-0• 5-5" 2 5'-4' 10 5-7" 45 '-TO'V-4' (ON TOP) ADOPTED FROM ADOPTED FROM NCDOT STANDARD NCDOT STANDARD survey by: JTR SHEEP 2 NO. 840.00 2 NO. 840.15 •, ,1 .1 DATE 3/18/2008 DRAWN BY CSA DATE 3/19/2005 DRAWN Of C.W. DATE 3/24/2008 DRAWN BY C.W. �� DATE C� checked by: JAYN CAD FILE : BRICKDBLCB DR-4 SEA N.T.S. CK'D BY JPB CAD FILE : CONBPPAD DR-9 SG1E N. T. 5. CNb BY CA CAD FILE : Dro nleta DR-11 . 1 504E N.T.S. CM0 BY CA 6 CAD FILE : 4ON27RC SCALE JPB sheet no.: Know what's below. C 19 Call before you dig. i 1. CONTRACTOR SHALL REPAIR ALL SEWER LATERALS AND MAINS DAMAGED DURING B. CROSSINGAWATERMANOVERAMWER WHENEVERITISNECE$SARYFORA CONSTRUCTION. THE CONTRACTOR SHALL IMMEDIATELY REPORT ALL SEWER MAIN WATER MAIN TO GROW MRRA SEWER THE WATER MAIN SHALL THE PWC PROJECTCOORDINATOR.TOR. THE LONTPFCTOR AN E BOTTOM OF THE BOTTOM OF THE WATER MAIN ISgT SANDHALATERATEfMMESTE SHALL IMTMTE IMMEDIATE REPAIRS IN ACCORDANCE WITH PVYC bTANDAR0.4. LEIAIDATSUCH MOVE SABOR OF LEAST MR OF LAME% CONDITIONSBARRIERS LOCALCONDITIONSORBARRIERS"INANTMfER VERTICAL VENT AN 18 INCH UIE MARHOL%LHEL REINSTALLED (ITILRINGAEWE 2, SEWERMINNS,ED IN H THE TER SEWER SHALBE AR 9HgLL BE CH APPROVEDCWSHEET, INDICTING INSTALLATION DEPTH. INDICATING CONSTRUCTED FERROUS MATERIAL CONSTRUASECTED OF MATERIE AND JOINTSE JOINTS THAT WATER EQUIVALENT TO WATER MAIN STANDARDS FOR A DISTMGE OF IOFEETON RA OF10F 3. TRANSFERINSOF EACH SIDE OF THE POINT OFCfU)$,41NO. LANDERSERWCESSHAANHOLICOMPLISHEO/SFOLLOWS: MAINS,MANHOLEHAND LATERALS. SHALL A. INSTALLALED IFNEW BE INSTALLED,BM BINV WFIV, EHE C. CROSSINGWATER UNDER ASEWER: WHENEVER ITI B. CONNI PLUMBING TO NENLESS W LATERAL, NECESSARY LATERAL WBRING THE NECEWARY HOLDING CROSSU . THESARYFORA TO CRO%UNDER M BOTHCTILEHIER MAIN MTINGSDOSTINGPLUMBINGTONEW E FFTER CES TH AND THEM SHALL B E HE SEWER MAWUTEPAL SHALL BE CONSTRUCTS OF DUCTILEIRON CONSTRUCTED ALLS I SERVICESHAVE BE TO THE C. AFTER ALLLTAFF ESHAVE BEEN TRANSFERBE MATERIAL AND OINT ANDARDS STFOR A MAINOFCR NCEMAI SEWER SYSTEM SHALL BE PBANDJNEOINAWOROANCE WITH PMC ACCORHE DANCE DISTANCE OFIN FEET CHSIEQUIVEENTTOWATER LAN . MCEOFIOMT SIDEOFTHEPOEPOI CPpSCROSSI3ECRON REpU1REMEMS. REQUIREMENTS. HALT SE OF WATER MAIN PIPE SHALL%C OF POINT Oc CRU861NG. 4. WHEN THE EXISTING MAIN IS NOT TO BE ABANDONED THE CONTRACTOR SWILL D. CROSSINGSTORIADRANAGELINEST. A MINIMUM OFVERTICAL UNCOVER THE MISTING CUt AND REMOVE 124-INCHES SHALL MAINTAINED BETWEEN A WINES ER MAI W LATERAL CROSSING THE LEANOUTAND COMBINATION, CLEgNOUTANO COMBINATION,pNp PLUG THE IATERALTO ABVJ00N THE TO UNDER ASTORM CROSSING SE PIPE IS USED, OLDSEEXISTING TIE OLD SERVICE. DUCTILE IS MINIMUM ARCHESOF SLY01DUCTILEINCHES USED.IF DUCTILE IRON PIPE ISUSED,AESS SEPARATION SHALL BE MAINTAINED, UNLE%OTHERNISEAPPROVED BY PWC. OTHOFSISE D ALLTHE REINSTALLED ATE OTTER MATERIAL S. FEWEFROM NY DEBRISACCEPTA ENDURINGGS FROM ENTERING THE ACTIVE UPONC SEWER SYSTEM. UPON ACCEPTANCE OF THE NEW SYSTEM. ONTR SEWER SYSTEM THE CONTRACTOR SHALL CLEAN THE NEW MAINS REMOVEALL. CEBRS, ANDTiEN REMOVE THE PLUG, B SEPAFAT=MQUIREMEM3: A. UTEMLBEPpRATON OF BEWEII3MDWATERMAINS: WATER MANS SHALL BE LAID AT LEAST 10 FEET UTERALLY FROM EXISTING ORPROPOSED SEWER MAIWL MM,UNLESSLOCALCONDITIONSORBARRIERSPREVEWAIDFOOT LATERAL SEPARATION - IN WHICH CASE: I. THE WATER MAIN IS W D INA SEPARATE TRENCH WITH THE ELEVATION OF THE BOTTOM OF TIE WATER MNN AT LEAST 161NCHW ABOVE THE TOP OF THE SEWER MANMTERAL; OR I. THE WATER MAIN IS LAID IN THE SAME TRENCH AS THE SEWER MAIWUTERAL WITH THE WATER MAIN LOCATED AT ONE SIDE ON A BENCH OF UNDISTURBED EARTH AND WITH THE ELEVATION OF THE BOTTOM OF THE WATER MAIN AT LEAST IS NKHM MOVE THE TOP OF THE SEWER MAIWLATERAL GENERAL NOTES PUBLIC WORKS COMMISSION 11,10.1 DATE 1REVIs1oN SANITARY SEWER UTILITY FAYETTEVILLE, N.C. SHEET No. DWG. No. S.i wNc. Bv: Rvc WATER RESOURCES +oE+ ENGINEERING DEPARTMENT DATE: JULV 01 2013 APPROVED BY: JEG 2013S1 SEWER NOT%dvg NOTES 1, MANHOLE MEETSEL WQ. 5. A DROP STRUCTURE SHALL BE OF AMEX CATS, PLACED WHERE PIPE VERTICAL 2. CONCRETE IS MINIMUM 10(M PSI SEPARATION BETWEEN INVERTS EXCEEDS 2SIT USES 6 DIAMETER COMPRESSIVE SiRENSPH MANHOLES WHEN DROP STRUCTURES 3. MATERIAL USED TO SEAL MOUND AW NEEDED. PIPE SHALL BE NONSHRINK GROUT. S WITH THE EXCEPTION OF THE 4, MANHOLE SHALL BE CONSTRUCTED MANHOLE WE SECTION, ALL OF PREDATE CONCRETE. FIBERGLASS OTNERMATERMLS, INTOILATION MANHOLE ISNOTACCEPTARE. ANDWORKMANSHIPSHALLBE B IN ACCORDANCE WITHME PWC STANDARD MANHOLE DETAILS. T. DOGHOUSE MANHOLE SHALL E FREE ® OF LEMS AND HAVE NO SIGNS OF VISIBLE LEAKAGE. ® & MANHOLES GREATER THAN 121N DEPTH SIMILWWEMIN EXTENDED SHELF DETAIL 9. SEE STANDARD MANHOLE DETAIL FOR MANH DETAIL FO SHELF__.__ \\ g001TIONAL REQ111HEMENTS. MOTION A LONSTRIICT N VERi M 40° MIN, ACCORDANCE WITH EPIC STAMTAROS CONCRETEINVERD ADD R AC N T NEW TO BOTTOM OF PIPE SANITARY SEE SHELF DETAIL FOR SP SHELF CONSTRUCTION. i E NONSHRINK SEE SHELF DETAIL FLEXIBLE RUBBER BOOT ry GROW (SOLID BRICK B MORTAR) FAMENEDW/T304STNNLE% SEALMNULU90VER STEEL KORBAIJD TO MH AND MOUND PIPE AT -REINFORCING MEET T300STANLE%STEEL OOGHOUSEWITHSC1L10 ISO MAX. WINED. ASTM A1050.1230.IN. PRE CLAMP BRICKMDMORTAR i WMIN IF FORMED, $ IF UNFORMED EMEND NEW SANITARY SEW S b m a af`To UNDISTURBED SOIL AND UP TO SPRING LINE MANHOLE FAIR MOTION F OF PIPE $HALL BE SUPPORTED ON °' C MONOLITHIC EDIFICE CONCRETE 4XI'X10• SOLID CONCRETE - EXIST. SANITARY •� INVERT AND BASE PLACED IN BLOCKS STACXED2 HIGH FEWER OUT FIELD TO BOTTOM OF PIPE. 1B0°MART. REMOVESUSTINGTOPOF 6xBNBXW9 WWM 8067STOMPACTED Obi STONE PNEABOVE SPRING LINE AFTER BASE ONLY { ICI SEAL ANNULUS OVERLAID ACCEPTANCE OF MANHOLE BATE BY 0' MIN. COMPMTED -(IIIII MOUND PIPE AT DOGHOUSE PWC. CONTRACTOR SHALL SAW CUT AND REMOVE EXISTING PIPE CROWN NO 57 STONE IL UNDISTURBED WRHPDLIOBRCKMOMORTM TO FORM OPEN INVERT }ROUGH. 4WEIVESDUDCONCRETE SUBGRACE NO DEBRIS SHALL BEALLOWED BLOCKS STACKED 2 HIGH BBWRXW'8 WWM TO ENTER SANITARf SRVBi 100•APPAT SECTION Bb BASE ONLY DOGHOUSE MANHOLE PUBLIC WORKS COMMISSION INI DATE I REVISION 1 nnsroe MADE CNMGES TO NOTES N.T.S. FAYETTEVILLE, N.C. SHEETING DWGND, S'3 DWG, BY. PAC WATER RESOURCES � 1OF1 ENGINEERING DEPARTMENT 1DATEIJULYT1,2013 APPROVEDBY: JEG. FRAME PLAN WE COVER _:_ ♦ _ i\1�PICK SLOT DETAIL !I =;I ITCH..... title mH TMII m NOTES: 1. DETAIL TO BE USED IN PAVED AREAS ONLY. ALL OTHER ARMHOLES SHALL BE IN ACCORDANCE WITH DETAIL SA UNIESSOTHERWISEAPPROVED. 2, MANHOLE FRAME AND COVER SHALL SE MADE OF GRAY CAST IRON CONFORMING TO ABIM SPEC. AAR33 CT 3LV35 RESPECTIVELY, MANUFACTURED BY SAME MANUFACTURER. ALL CASTINGS SHALL CONFORM TO THE SHAPE AND DIMENSIONS SHOWN. THEY SHALL BE CLEW AND PERFECT, WITHOUT BLOW OR SAND HOLES OR DEFECTS OF ANY KIND, TENDING TO IMPAIR THEIR STRENGTH. NO PLUGGING OR STOPPING OF DEFECRNE HOLES WILL BE PERMITTED. 3, CASTINGS SHALL BE UNPAINTEDANO SHALL HAVE THE LETTERS'PNGFAY-NC' AND "SAW?MY SEWER' CAST INTO COVER. LETTERS SHALL BE RAISED AND CLEARLY VISIBLE. 4. MANHOLE RING AND COVER SHALL WITHSTAND A VEHICULAR TRAFFIC. ROCKING COVERS SHALL NOT BE ACCEPTABLE. 5. MINIMUM AVERAGE WEIGHT: PLUS OR MINUS I RING 175155., COVER 135 LBI UNIT$10 CBS. 6, PERFORATED COVERS WILL NOT BE ALLOWED P ly FRAME FVM'- BED OF CLEAN FRESH /1! a pt TAyA MORTAR(TYE) J 1 31• 0 CONCRETE COLLAR -PAVED AREAS >' a THICKNESS PSI CLAS6'A• CONCWTECOLLM"NIAIR yE Wpp O ENTRAINMENT ALL AROUND FRAMS. A (WHEN UTILIZING CONCRETE GRACE N RINGS THE CONCRETE COLLAR SWILL EMEND TO z [R BELOW THE TOP OF COVER A46A3,CLW CONE.) COVERFACE STANDARD TRAFFIC AREA MANHOLE PUBLIC WORKS COMMISSION INCIRATE RING AND COVER FAYETTEVILLE, N.C. + JM DS CHANGED! NJ4. ,�O• 2 JULY06 ADDED NO SHEET No owG'No, S7 OwG. sr: R2 WATER RESOURCES ���% 3 FEB O] REwsED Nl I OF DATE JOLY01,- APPROVEDBN JEG ENGINEERING DEPARTMENT 4 JLnr 9. WVISEDA ;PHALTMICK SEWER SERVICE LATERAL NOTES 1. HOLE IN SANITARY SEWER MAIN MUST BE CUT WITH 11, SEE INTERIOR DROP STRUCTURE OR SLIDE, MORTAR SLIDE SHELL CUTTER NO HAMMER TAPS ALLOWED. SHELF DETAIL FOR VERTICAL DROPS OF MAINS AND LATERALS. 2, LATERAL SHALL CONFORM TO ASTM SPECS. D-MU 12. LATERALSLESSTHM TIN DEPTH ORGREATERTHANWDEPTH SHALL SDR-28 UNLESS OTHERWISE INDICATED AS D.L UTILIZE DUCTILE IRON PIPEMD FIRINGS WITH CERAMICEPDXY RROTECTO 401) 3, ALL PIPE & FITTINGS SHALL BE 4. OR V UNLESS OTHERWISE SPECIFIED. 13. ENTIRE SEWER LATERALA%EMBLY SHALL BE AIR TESTED CONCURRENTLY WITH SEWER MAIN. 4, ALL D.I. PIPE SHALL HAVE AR INTERIOR LINING OF LEMMIC EPDXY (PROTECTO WED THE ENTIRE O.I. 14. INDIVIDUAL LATERALSSHALL BECLEARED AND FLUSHED PRIOR TO LATERAL SHALL COMPRISED OF D.I. PIPE 8 FLUSHING SARITgRY %WERMNNS. FITTINGS. MECHANICAL JOINT FITTINGS. 15. LATEPALSHALL NOT BE BACK -FILLED UNTIL INSPECTED BY THE RVC B ALL CONNECTIONS SHALL HAVE RUBBER GASKET SEALS PROTECT COORDIHATOR. INSTALLED. 16. N'VE CONNECTIONS SMALL NOT BE USED TO TIE LATERALS INTO 0. SMITHY FEWERSERVICE CIO STACK SHALL BE MANHOLE. LOCATED 13F' FROM FROM WATER SERVICE LOCK VALVE WHEN IN THE SAME DITCH, BY THE PROJECTCOORDINATOR,UNDISTURBED t]. IF SENDSMJEREQUIRED EBTOO INSTALLED FROM UNDISTURBED (SEE BEDDING IS (SEE T. OTHER THAN AS SHOWN MUST BE SOILT DETAIL S]2)SOILID BOTTOM OF BEND. APPROVED APPROVED BY THE RYE. BE MOLDED BEND. 18. FIVERGE, B. CONNECTIONS TO THE TOP MPIPROVED NOTHE EN RAPPROND By D EQUTEO, SOR2G, AS MANUFACTURED BY HARCO,GPK OR APPROVED EQUAL. AS MATION NUFACTURED UR IS ALLOWED, OTHERWISE APPROVED BY THE RYC OORDI PROJECT COORDINATOR. 19, NOMORE TER 4, INCH ITERALS ORAL SIXINCHLATERALS DIAMETER THAN $HALL ENTER A 4' DMMETER TERMINAL MANHOLE. NO MORE THAN 2 9. SLOPE OF THE LATERAL L BE PTHBY LATERAER (WGMAN LE ENTERAL OTHER ETOPOGERVICE THE LOTAS DETERMEDBYTTHETOPNGMPHY OF THELOTAS DETERMINED SSHHALL ALL LATESHALL HAVE DIVID DIAMETER MANHOLES. ALLI THE PWC ENGINEER OR AS INDICATED ON SHALL IF THE THOUGH MANHOLES SHALL BE USED IF THE MOVE THE DRAWINGS. THE DRAWINGS, ONDITI NSA RE NOT CONDITIONS ARE NOT MET. M LATERAL SHALL CONFORM TO THE 2%MINIMUM SLOPE 20. ALL LATERALS(PANDS•) SHALL UTILIZE A4• RISER (STACK). FOR THE 4' ORTHE 1%MINIMUM SLOPE FOR THE li MP%IMUM CLEAN OUT SPACING FOR 4' PIPE ]5' fi' PIPE 21. REFER TOOL TAIL SA2 FOR SEPARATION REQUIREMENTS. iW'. THE FOLLOWING TMLE SUMMARIZES THE MATERIALS TO BE UTILIZED FOR SEWER MAIN TO LATERAL CONNECTIONS'. PVC MI DI MMn 01 LNb NBI DIRNM mm. PVCLWRd PVC W., B, OdoM MJ RdIn•wNN trenNtlen BOAR OIMM SEWER SERVICE LATERAL PUBLIC WORKS COMMISSION IT DATEEME REVISION NOTES (4-INCH AND 6-INCH) FAYETTEVILLE, N.C. , uTV IB WseD HITTES 4&.ADDED SHEETING DWG.NO. $,1' DWG.BC PWC WATER RESOURCES 2 CT 11 VISED NOTES 1 aF1 DATE: JULYD1.2D13 APPROVEDBY: JEG ENGINEERING DEPARTMENT 3 M.13 EVISEO NOTE. AND ADDED TABLE PIPE SIZESF MANHOLE SIZE I MIN. WALL THICKNESS I MIN. REINF. STEEL 1 MIN. BASE THICKNESS 21'fl LE% d8'DOVAETER 5' A6TM A-165012 SCI 1 B• 24'-39' ti ASLM A185015 MAIL -I IF 42' -80'DIMIEIER ]2'DIAMETER T ASTM A-185815 SDI 1 S' MANHOLE DIAMETER SIZES MAY BE ADJUSTED ON THE PLANS TO REFLECT SPECIAL CIRCUMSTANCES. REDUCING SLABS ARE NOT ACCEPTABLE ON MANHOLES LESS THAN OR EQUAL TO F OIAMETER. CAST IRON FRAME& COVER SEE DETAIL MBX.(3)4', (2)W, OR FLEXIBLE BUTYL RESIN $ ? (1)T GRADE RINGS ® SEALANTORRUBBERGASKET MANUFACTURER INSTALLED POLY 3 SEE NOTE 13, JOINT. PROPYLENE COATED Tx In ® STEP OVER INVERT OUT SEE STEP DETAIL. i JOINT 10• SEAL INSIDE AND OUTSIDE OF p_ 0 SEALER JOINT WITH FAST SET MORTAR F w SMOOTH FINISH bo U� ¢W �,cT ury eenne erre.m NeiiN RVC RINGAND COVER SE DETAIL (2 TYPES OF RING AND COVERAPPVM CONC. GRACE RING MAX. 3 4',(2) B OR 1 2'. SEE NOTE ,3. ECCENTRIC REDUCER _�JOINT SEALER EE LIFT HOLES FIE){. BOOT v CONNEC OR CONE. BRICK AND MORTAR AVERT OIN SEALER ¢- I FIELD TO OF j OUTLETPI E FDETAHEIGHT DUVET PIPE SEE SHELF CETAILPAL AROUND PIPE -REINFORCING J SEECHARTABOVEPEEWEE DETAIL _ BEE CHVET �-SEE NOTE 3 m� F MIN. COMPACTED NO 57 eFLUSLE STONE EPDM RIBBER - III III IIIII OOT __ - ANITARY SEWER IDUT) UNDISTURBED SUBMADE SEALANNULUSAROUNOPKEAT ENTRANCE WITH NCNSHRINK O V STONE GROUT. PUBLIC WORKS COMM ISSION No DATE REVISOR STANDARD MANHOLE FAYETTEVILLE, N.C. 1 EBW REATED52A ADDED NOTES 131] DVVG. NO. 5.2 DWG. BY. RAC Nova 2 ULY 13 DEED SHEET 2 OF SHEET NO WATERRESOURCES DATE: JULY01,2013 APPROVEDBY: J.E.G. 1 OF2 ENGINEERING DEPARTMENT MI Y52 STANDARO MANHOLE do ew,TXNGYPEBN »nERT 9PRINGLINE OF PIPE In'ix10F NCwxGw,4. CAL AROUND NONSH RMN GPOVTSLIOE STIRR.b. x.PFF In. I¢W wxEl¢ IPE VOE 12 pIF£PLACEOIN FIELA SOLIDLIGN I.H�� SIE3 CONCRETEJVMBOBRCKMAYPE mxs Nwuanw wEaunLVER EA mwUT INVENT USED TO BVILG UP INYFATTOGxEwT INFAR QUANTITE3 .REDUCEM ,EBDDE$HALL BE INSTALLED ON PIPE TOP OF SHELF WITH ATROUGH RI.ETµo SFIPESLICEDETAIL i0 DIRECT FLOW INTO TIE HELF SEWERcwrmx•,ipa INRA, amtncx�LOWCHµNEL AWNEIGHT MYMp1F vETNxHAPETOY4 OF OURET IPE.IN En..FN evr,asawwx ILO m.Nm NITS UM.H, BEGIN SHELF TRANSITION .IX AT. HEI.M.F.UIEST .IXUB' 9E. PIPE 1:12 MIN hm MAuxEE NE08 ALIGN STEPS CONCRETE SHELF %OLEO M ALIGN STEP& EFNI EP En'N'EEKPPWEn BYMC OVER IXYERi BEU OVERINVEM - N Fd OUT JUMW D ICRMAYBEO JUMSo REEKMAY TO BUILD UP INVERT TO OUT RpW.,EW,EMENtS ta. WiY..I.OKE SEX -AROUND REDUCE MORTAR QUANTITIES. SHELF vPIPTAIFnrs AYLIT.NtuTExus PIPE BMLDTROLGNTO EMExxG Vµxc A. PL TINE➢ IN WT 011y &PRINGUNE OFPIFE uI u' .TIR15P ON EXISTING MANHOLES IRE P+',wtFS OBE ei81®V+L L/ITEPnu OTIEnn' BOTTOM OF FOOT REASSH ALL _ BE SET t•MOJEbHELF /- xyxiay,ll, ,T-1. NAN.IIs,uu 6EIWP` �xEAanBT�a UJ4ueIw MORTAR SLIDE 5.5. u�wNeF SHELF-xOu],E TxwxSUTEw.Ls sxNe Exrtaes vuEcrEx TEOxu v-w _ � , T vrcwx. TESTEowu'aNVNx£ eS W PNcs el�Pm N SLOPE TOP OF CONE SEA AROUND PIPE FLONCHANNEL SHAPE MAN. TOWARD TROUGH INVERT SHALL ENTER MAX, TGWARO TROUGH. T03N HGGHTCF. PIPE. MANHOLE I-HISPROVE LOW CHANNEL SHAPE MORTAR SLIDE DETAIL SHELF RYPI TO M4 HEIGHT OF CUTLET WS PIPE' SHELF DETAIL NTS PIPE SLIDE, MORTAR SLIDE PUBLIC WORKS COMMISSION NO. DATE REVISION AND SHELF DETAILS FAYETTEVILLE, N.C. II JAN.Ds JAGGED NOTE& DWG NO. DWG. BY: PWC 2 FES OT ISED NOTE BSLIDE DETAIL. SHEET No. 5`4 WATER RESOURCES ACCED ROT% to 111z t OF, ENGINEERING DEPARTMENT DATE JULYD1,2013 APPROVEDBn JEG, 201354 PSLIDE.Us, NOTES: 12 GRADE 60 L COPOLYMER POLYPROPYLENE PLASTIC STEEL REINFORCEMENT STEP SHILL BE PLACED IF GC IN ALL STRJCTLRiES 5' DEPTH OR GREATER- 2 STEPS SHALL BE INSTALLED BY ALIGNED OVER STRUCTUREINVERT OUT. 3, DIMENSIONS SHOWN ARE TO CONVEY THE DESIRED SIZE OF THE STEP. STEPS SECTION'I OF SIMILAR SIZE AND CONSTRUCTION MAY BE ACCEPTANCE FROVroEO MATERIAL SUBMITTAL IBAFVRDVED SYFWC. 4, MATFFIN-s OF CONSTRUCTIQV PAV METHOD OF INSTALLATION SHALL SE IN ACCORDANCE WITH OSHA STANDARDS MOASTBI C<I6. SERRATED TREADS WIDE ENOUGHTO PLAN VIEW FRONT VIEW OP 1 fld' aye• ARMHOLE WALL :e s•MM. x SIDE VIEN ISOMETRIC VIEW OF STEP NO. DATE STRUCTURE STEP PUBLIC WORKS COMMISSION REVISION rvTs. FAYETTEVILLE, N.C. SWUNGg,B TWO. BY: FOUL WATER RESOURCES 1 OF1 DATE: Jm.r 51, 2013 APPROvsO Bv: JEG. ENGINEERING DEPARTMENT 20' 10' MIN. HORIZONTAL SEPARATION SETWEEN WAFER ANDSEWEROD TOOD IT MIN. FHORZONTAL SEPARATION BETWEEN WATFF AND SEWER GO TO OD - WATER MAN HE MINIMUM SEPARATION i CLENNOUT SHALL E SET I EXISTING STORM GRAN BETWEEN BOTTOM OF WATER TO ELEV. INDICATED ON PLANS EXGAS AND TOP OF SM SEWER 0 EX UNDERGROUND OTHERWISE, KIM THE CROSSING IN ACCORD WITH ELECTRIC LATERAL BWATER MAN SHALL REQUIREMENTS UNGERGROUND BEDT. IFWATERMAIN ISEX, ONLY MAKE BE LATERAL DI. ELECTRICAL CROSSINGS f1 A CROWING IN ACCORD WITH SEWER REQUIREMENTS FOR UNDERGROUND ELECTRICAL CROSSINGS 24' MINIMUM SEPARATION FJOSTING� IF SEPAAATION BETWEENBOTTOMOFSTOBY STORM ORNN BETWEEN BOTTOM OF GAS �� CLEANOUT SHALL BE SET AND TOP OF SAN SEWER, AND TOP OF BAN SEWER FO ELEV. INDICATED ON PLANS OTHERWISE LATERAL SHALL SEWER BE OL MAIN ,8' MINIMUM SEPARATION BETWEEN BOTTOM OF N BOTTOM CF GAB \ AND TO BETWEEN BOTTOM OF WATER AND TOP Of SAN SEWER AND TOP OF SVN SEWER, \ 24• MINIMUM SEPARATION IT MIN, HORIZONTAL OTHERWISE, BOTH THE \\\ BETWEEN BOTTOM OF STORM AND SEPARATION BETWEEN WATER WATER MAIN LATERAL& WATER MAN SHALL TAP OF SON, SEWER, OTHERWISE AND SEWER OO TOOD GK BELL IFW I IS EX., LATERAL W ER ONLY MAI(E SS LATEpAL O(. ALL VERTICAL SEPARATION &EPARATON SHALL BE IN EXISTING UNDERGROUND WITH STATE ACCORDANCE WITH STATE REGOIATroNS. ELECTRIC 2 THE SKETCHES SHOWN ARE FOR INFORMATIONAL PURPOSES IF MINIMUM SEPARATION CLEANOUT SHEL R EFF ONLY. BETWEEN BOTTOM DEVIATOR TO ELEV. INDICATED ON PDUNS AND TOP OF SEWER 3. THE CONTRACTOR SWILL BE REQUIRED TO VERIFY ALL EXISTING UTILITIES BOTH HOO20 MpVERTICALLY TEACH BOTH BOTH THE G PRIOR CONSTRUCTION OF LATERAL. TO INHERE L,TOTHERWISE CROSSING . PROPER PROPER CLEARANCES ARE MNMNWD. CLEARANCES ME MAINTAINED, BEDI IFAWATERMNNSHEL BE DI. TF WATER MAIN Ib IX., Sp REQUIREMENTS FOR UNDERGROUND REQUIREMENTS FOR UNOERGROUNO ONLY MAW WLAFEMLDL ELELTRICE CROSSINGS q ALL PIPE BEND LOCATIONS AND MAX. NUMBER OF BENDS INSTALLED ON LATERALS SHALL BE APPROVED BY THE PROJECT SEWER iMAIN COORDINATOR PRIOR TO INSTALLATION OF KIND OR EXTENDING 10' MINIMUM SEPARATION THE LATERAL FROM THE MAIN. I EXISTING BETWEEN BOTTOOF GAS STORNo RAIN ANp TOP OFSM SM EWER 5. ALL REQUIREMENTS FOR SEWER LATERAL NOTES AND DETAILS ABLE SHALL BE APPLICABLE. 29 MINIMUM SEPARATION BETWEEN BOTTOM, BREFMATO UNDERGROUND ELE NAL OUND ANDTOP MOTHEHWISE OTHERR NDERG ELECTRICAL INFORMATION WHEN CROSSING UNCERGROUPID ELECTRICAL LATEM13HgLL%DL SHIB FACILITIES SEWER SERVICE LATERAL NQ DATE REVISION PUBLIC WORKS COMMISSION UTILITY CONFLICT SEPARATION FAYETTEVILLE, N.C. REQUIREMENTS 1 AN Ds REVIs3u rvoTEs1 ANDS SHEET NO. DWG,NO 'S'12 Owc. eY FIND WATER RESOURCES z NOV o6 MDE0 NOTE ON DI LATERALS 1 DF, - DATE: JULV 01, 2D13 APPROVED SY: ENGINEERING DEPARTMENT 3 10 ACDEO LATERAL &WM SEPARATION 2013S12 UTIL CONFLICT MOTES 13. CONCRETE GRADE RINGS SHALL NOT BE USED FOR ABOVE 1. PRECAST REINFORCED CONCRETE MANHOLESSHALL%IN GRADEADJUSFMENFS(T.,OUfFALLARNS), USEOFGRADE ACCORDANCE WITHASTIACJ]B RINGSAAEALLOWABLE INVAROARE ANDPAVEMENTWHERE THE RING AND COVERAREATGROUND LEVEL. 2. MINIMUM CONCRETE COMPRE%NE SIWNGTI SHALL BE 40M PSI. 14. THE MINIMUM SLOPE ACROSS THE INVERT OF THE MAWKJLE 3. MANHOLES GREATER THAN 12 DEPTH BRAT HAVE MINIMUM 6• SFWI BE I%, UNLE% OTHERWISE APPROVED BY FINE. EMENDED WE. 15. THE EXTERIOR MANHOLE RISER JOINTS, INCLUDING THE JOBD'AT 4. FLEXIBLE BUTYL RESIN JOINT MALAWSFULLL BE INACOOROANCE THE CONE, SHALL BE SEALED ONTIE OUTSIDE BYAN APPROVED WITH ASTM CNK. RUBBER GASKET JOINTS SHALL BE IN JOINTWMP, THE WRAP &HALL BE INACCOROANCE WRH PIVC ACCORDANCE WITH ASTM 0443. SPECIFICATIONS. 5. FLEXIBLE EPOM RUBBER SOOT CONNECTORS SHALL BE IN 16. MANHOEBOOTFORLINCHLATERALS. SHOULDRBE ACCORDANCE WITH ASTM CM.INSTALLEE/BY MANUFACTURER NECESSARYTOBSTALLA4-INCHLATEPALINMAMMIHOLETHE WITH STAINLESS STEEL COMPRE%ION RING AND T&I CLAMP. RUBBER BOOT THAT THE LATERAL IS INSERTED WO WALL BE CONNECTION TO MAIN SHALL BE BY CONTRACTOR WITH SECURELY FASTENED TO TIE CORE HERE BY UTILIZINGA STAINLESS STEEL PIPE CLAMP. STAINLESS STEEL BARD THAT IS TIGHTENED USING A JACK ORAL TORQUE WRENCH OIRECTORIVE. FKAMSTANICARDWEAND 0. CONNECTIONS TO EXISTING BHINJIL BY WRING TOROVE STEPDOWNBWTHE STALLIMANHOLES OOTC INSTALLING REX BOOTCONNECTOR. CO BE SUPPMETHOD ED MANUFACTURES. TYPE BANDS ES. NOT ALLOY/ DEBRIS TO ENTER SYSTEM. NOT ALLOW DEBRIS SYSTEM SECURING THE 300TTT THE MANHOLE HAUB OR METHOD OF %WRING THE SOOT TO THE MANHOLE SWLLL BE ACCEPTED ]. MORTAR DIN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS ACCORDANCE ITQUICKFATNGRS RECOIMMENDATIONS THE FOURAMETES GFOR 3PIPE 5INCHESITE WAIL DIAMETER RANGE OFTHE BOOT SHALL BE 3S INCHES 10425 RANGE FT THE 8. MANHOLE STEPS SHALL BE INACCORDANCE WITH ASTM CATBAND INCHES. OSHA REGIILATION3. rYIGN STEPS WITH INVERT OUT. FOR FOUR IRON TIE PIPE OUTSIDE FTHE 9. NOT ALLOWED STANDING WATER IN RANGE DIAMETER EITHER BE AS FOR VC OR S ALL EITHER INVERTPRECASTINVEROLE IS INVERT OF MANHOLE IS NOT ACCEPTABLE. 4.251MA^ LEG T04.81 INCHES. III VERTICAL DROPS BETWEEN THE INFLOW PIPES AND OUTFLOW IN ALL CASES, THE BOOT SHALL BE TIGHTENED ON THE LATERAL PIPES SHALL REQUIRE THE FOLLOWING: BY MEANS OF SINGLE STAINLESS STEEL STRAP, A. GREATERTHAN25'SEEDROPSTRUCTIRE DETAIL (MIN. 5' DIAMETER MIN REQUIRED). THE LATERAL INVERT SHALL BE AT TIE TOP OF THE SHELF, B. Pi025'SEEP IPE SLIDE DETAIL. C. LESS THAN ISEE MORTAR SLIDE DETAIL. 17. NO MORE THAN 4, FOUR INCH LATERALS OR 3, SIX INCH LATERALS SHALL ENTERAW DWAETER TERMINAL MANHOLE. NO MORE 11, AN ECCENTRIC CONE SHALL BE MUZEDON ALL MANHOLES, THAN 2IATEMISTNEMiMDLE% OF SIZE) SHULL ENTERALL UNLESS OTHERWISE APPROVED BY FINE. DTHER4'CIAMETERMMHOLES. ALLUTEPALSSHALLHAVEAN INDIVIDUAL TROUGH. 5' DIAMETER MANHOLES SHALL BE USED IF 12 INVERT ON PIONS IS TO MANHOLE CENTERLINE. THE ABOVE CONDITIONS ME NOT MET. 18. NO NOW THAN 5 LATERALS SHALL EWER A S' DIAMETER 19, USE OF T=EWYES ON LATERALS IS HOT ALLOWED, M ALL MANHOLES SHALL BE VACUUM TESTED IN ACCORDANCE WITH RNC STANDARDS. PUBLIC WORKS COMMISSION Bo. DATE REVISION STANDARD MANHOLE FAYETTEVILLE, N.C. t 1108 FATED DETAIL, ADDED NOTES I4-20 TWO, NO. S.Z °Wc. er: FINE 2 7/13 ISED NOTE39, 10111.15 SHEET No. WATER RESOURCES 2 OFz DATE: JULY 01, M13 1 APPROVED BY: J.EG, ENGINEERING DEPARTMENT 201352 STMOARD AMNHIXE.O.p F MIN, SINGLE WIDE TAPPING SADDE WITH STRAP STAINLESS - AND ALIGNMENT FLANGE EE STLSTWW T IMAGO OR APPROVED EQUAL). SEE TABLE ON Sit I I FLOW /-4.OR6' EXTENDSTACK1FMINABOVE T-6 INLET GRADE WITH GLUE CM. FOR I / TESTING, AFTER TESTAE RYPJ PVC SCR-26 OR DJ. TEE • ACCEPTEDADJUSTSTACKTO q¢ PROPER GRADE AND INSTAL 8 SEE NOTES ]BBIXJ Git PERMANENT CLFANWTGAP w STANDARDTEE $� ASSEMBLYF-VMIEs r & CONNECTION TAPPING SADDLE 1 - - CAP SHALL HAVE (OPTIONAL) T COVERNCNTRAFFIC NOTE.TAP SHALL BE 410 RJMRSHAJA_M4'SOR- REPS ANZ'BE ?B PVC SE TAT GRADE INeRPAVED FOR 4.LATERAL, AND EXCEPT R SHALL BE 4• D.E. IF THE AREAS SHALL BE 610 FOR W LATERAL ITSELF IS DUCTILE IRON PERMANE W ASSY LATERAL. SEE CLEANWT GAP ASSY GLUE CAP OR MJ CAP STONE 5F MLL BE OPE2% Oµ4 MATESTING (TO N) M\N EXTENDED TO BED EL OF�A - LATERALCONNECTION 1'p»�INML - -- EXTEND %TO WOR FROM UNDISTURBED SOIL �NOSEI IIII PROPERTY UK(D.I. OR PVC, DEPENDING ON 0 CASTG -i III III III - III LATERAL MATERIAL) THREADED TIIRON PLUG ED + -III -III - EVE SCOMBINATION�GAS EE ED I=I II III IIII IIII-I II II_ NOTE IKON S.11)OR TRAFFIC CAP III - - III MECH JOINT FITTINGS, ® CY�J III- III III -III III - III IF D.I. LATERAL. - THREADED CASTIII=`�LIII- IRON HUB - `UNDISTUWEDSOIL T STAINLE% J IN STEEL HOSE C4- A AP' .C.GL T04' CJ.TIASTIC MIN. 1IJ THICK EPoM COUPLING C/O CAP ASSEMBLY NOTES SEWER SERVICE SEWER SERVICE LATERAL PUBLIC WORKS COMMISSION NO. DATE REVISION (4-INCH AND 64NCH) FAYETTEVILLE, N.C. I JANOT REVISEDCONNECTKJN SHEET rvo. DWG No. S.�p DWG. BY: I WATER RESOURCES 2 JULYDB DDEONOTM FORIELATERALS f OF DATBY JEG ENGINEERING DEPARTMENT a J. EVI%O E:JuIr DI, 2013 AwftovEO NorFS 2013SIO ma46 NOTES: 1. ALL EXCAVATORS SMALL COMPLY WITH THE TERMS AND CONDITIONS OF THE CONSTRUCTION STANDARDS FOR SEE PAVT PATCH DETAIL FOR EXCAVATIONS M OSHA -SAFETY AND HEALTH REGUwTKINS LAST BOF FILL IN PAVED AREAS FOR CONSTRUCTION, CHAPTER"" I OF TITLE 29, CPR, PART (. 1926, THE CONTRACTOR SHALL HAVE A COMPETENT PERSON Oq COMPACTED TO 95%MAX. DENSITY ON THE JOB AT ALL TIMES AND SHALL EMPLOY A PROFESSIONAL AS DETERMINED BY MEN DEBI ENGINEER TO ACT UPON ALL PERTINENT MATTERS OF THE WORK 2. REDOING MATERIAL QUANTITIES ME CALCULATED BASED - PCq, ON THE FOLLOWING TRENCH WIDTHS. BEDDING MATERIAL SHALL p I -R I I BE INSTALLED REGARDLESS OF PIPE MATERIAL. „ IIIII -, II FOR4YFQPOIB-8 �& 9 III-IIIII_�1 III IMF III L- FOR RCPIDI B-B'. D=5'-6• FOR30. 30'RCP/DIB-d$' D=4'E• R IIIII._ FOR 2P EVOA B-4 TYi FXCFIDI3: '-P FOR 18• PVGDI B R3' _ FOR 1S FVCNIB .D=3' FOR 10 PVCIDI B=2, D=3'L' UNDISTURBED SOIL IIII IIII- �" FOR.- PVC,OI NET,OE3'L' o Fj 3 THE BEDDING MATERIAL SHALL BE GRPNUVR, CLEAN, COARSE MCHFILL SHALL BE PLACED IN PEA GRAVEL, OR WELL GRADED CRUSHED ROCK T LAYERS AND COMPACTED PLACED IN LAYERS NOT TO EXCEED V LOOSE LIKE FOR TO RAN MAXIMUM DENSITY AS THE FULL WIDTH OF THE TENCH. DETERMINED BY AEON M90 {T TO IT ABOVE TOP OF PIPE l0 4. BEDDING SHAUL BE THE LOWING COANDPAIDFOR IN J CLASS 8 RACE WITH THE FOLLOWING CHARTTO RRODUCE SELECT BEDDING MATERIAL CLASS B BEDDING. NO OVERAGE ALLOWED SEE FOR IT PIPE.0opEM. OF PIPE - FOR 12 PIPE Op3IB, OF PIPE NOTE 4 (MIN d') FOR 1S PIPE 09, IL OF PIPE III(TWE) FOR IF PIPE 13y,3M. OF PIPE SUBBASE SHALL BE UNDISTURBED /IFOR 2P PIPE 15Od3,T. OF PIPE BOIL. WHERE SOIL IS DEEMED J FOR 3D PIPE.19PUNIL OF PIPE UNSUITABLE BY THE MC PROL I PIPE DW FOR 3C PIPE 25OE541. OF PIPE AUTIORIZEDAREA SHALL BE UNDERCUT FOR 47 PIPE 321 OF PIPE FOR d6`PIPE 30 yR, OF PIPE ANT MCKFI ARE WITH SELECL REDOING b MATERIE. MFASNOT AUCKFILUG0 B �- S BEDDING MATERIE SHEL EMEND TO UNDISTUR%DTRLlNCH AS UNDERCUT SHALL BE 84CKFILLFD SEE NOTES t 82. WELSMD TRENCH BOTTOM.OVEMCE OF BEADING MATERIEL AT CONTRACTORS EXPENSE WITH WILL NOT BE PAID FOR UNLESS SPECIFICALLY APPROVED BY SELECT REDOING MATERIAL . THE IN THE A W AMOUNT OF TH AUTHORIZED SHALL ONLY Y, PAID FOR IN THE AMOUNT OF THE AWHORIZEO QUANTITY S. BEDDING MATERIAL SMALL BE PROFERL1f RODDED MOUND THE PEW HAUNCHES. T. CONTRACTOR SHALL USE TRENCH BOX SHORING M ALL OPEN CUTS IN PAVED AREAS, TRENCH WI BE MAINTAINED AT THE MINIMUM PRACTICAL WIDTH. SEWERBEDDING PUBLIC WORKS COMMISSION NO. DATE REVISION N.Tb. FAYETTEVILLE, N.C. 1 -TS REVISMNOTES SHEET No. OwG. No,, DWG. Br FIVE WATER RESOURCES 1 oFt DATE: Ju,., z APPROVED eY: Jafl ENGINEERING DEPARTMENT 2013S13 SEWER REDOING, rCONCEPTUAL PLAN ONLY1 THIS DRAWING IS NOT A CERTIFIED SURVEY AND NO RELIANCE MAY BE PLACED IN ITS ACCURACY. THIS DRAWING HAS NOT BEEN REVIEWED BY ANY GOVERNMENTAL AGENCY FOR COMPLIANCE WITH ANY APPLICABLE LAND DEVELOPMENT OR OTHER C REGULATIONS EXISTING INFORMATION IS BASED l ON CUMBERLAND COUNTY G.I.S. DATA. PRELIMINARY DO NOT USE FOR CONSTRUCTION SHAPE FLOW CHANNEL TO SLOPE TOP OF CONCRETE M4 HEIGHT OF WTETPIPE SHELF(1:12 MINR:I2 MAX) SHAPE FLOW CHARNEL TOTOWARD MORE TOP OF CONCRETE TROUGH TI HEIGHT OF OURET RPE SNELF012MINR:I2MA>n TOWARD THOUGH I BL`W 3 0 LATERAL (LOCATION IONVAWEB) SEALMOUNO PINT RING AND CDVIT AND5TEP8 4•TROUGN ALIGN OVER INVERI'WT RINGANOCOVERANDSTEPS rOIR ALIGN OVER INVERT DR SLIDEDETAILIATERAL3 ENTERING MANHONHOLE, K&O SEE DEINLSA I&THE LITER INVERT SHALL BE AT THE TOP OF SHELF. AT TERMINAL MANHOLES,THE CROWN OF THE NOTES TAT REAL TL BE NO LONER 11'IWERIOROPERSTRUGMREWMIRED THANTHECROMNOFTHE 1. MANHOLE AND CONNECTIONS S. MANHOLE MEEiBALLflEO. OF WHEW VERTICAL SEPARATION BETWEEN OUTEGINGSEWERMAN,UNLEW SANHOLE INDCONNECCEWITI ASTMPATI INVERTS EXCEEDS 25p. SEE INTERIOR OTHERVA APPROVEDBYRN: W FINETMIDARDMNHOTE. &CONCREFEI8MINIIMIMdUAP31 DROP STRUCTURE DETAIL 2, BRICK USED FOR nVERTANO COMPRESSIVE SIRENGIX, 12, VERIFY SLIDE INSTALLATION 1T. NOMOW MM4 FOURINOH T. MANHOLESGREwTER THAN 12 IN DEPTH WHIN PROJECT COORDINATOR IATERE3pR3 SIX INCH LATERALS SHAMINALM APDIAMEIER BE NCWTST pggp CONCRETE BE HCOCONSTRUCTIONCSHALL CR AN SHEL HAVE MIN. B'EXTENDED RISE PRIOR TO CONSTRUCTION. TEAM JUMBO BRICK,1MMONG CEPT TN CSSGRADE A EXCEPT B.&EE&TN4WRE MANH0.E pETNLFOR BE 13, MANHOLE OR ANDCE 2 LIMERLMANACLE.NOMOW 2MALLENBR DFMET L ABSORPTION LESSlH4H 10 ADDITIONAL REQUIREMENTS. IREMENIB. WITH PAIDN TAN4L IN ACCORDANCE WITH PWC STANDARD, SHALL ENTER ALL OTMER4'OIMAETFA ALL OTHER SC BUF B. MOWM9UOESMLL BE USED FOR MANHOLE DETAIL. MMHOLES.ALL LATERALS SHALL LESS THAN 1 FOOT SEPARATION HAVEN INDNIOUpL TROUGH UNLESS 9. AUTETHA BETWEEN INVERT OUT BINVEST OF 16. INVERT IMUMSLOPEAUL THEYHAVEASUDEORDROP BE PIPE BNEI BE NIXVSMUNK(LiOUT. INCOMING PIPE STRUCMW. B DIAMETER MANHOLES OF THE MANHOLE SHALL BE t%.UNLESS OF THE BE 1 4. MANHOLE WALL BE CONSTRl1CTE0 ,U OTHERWISEMPROVEDVIRAC. SHALL BE USED IF THE MOVE OF PRECAST CONCRETE FBERGLASS 10, PIPE SLOE RED D WHERE VERTICAL CONDITIONSAWNOTMET. MANHOLE IS NOTMAkPFABLE SEPARATIONBETWEENPIPEINVERTS 15. WHEN EXTENDING IN FUTURE, 18, NO MORE THAN 5 LATERALS SHALL IS GREATER THAN I' AMID LESS THAN CONNECTTO EXISTINGMHPER ENTERATDMNETERMANHOLE OR EQUAL TORT PWC STANDARDS 19, USE OF TEE -MESON LATERALS IS NOTELOWEO. PUBLIC WORKS COMMISSION NI DATE REVISION TERMINAL MANHOLE FAYETTEVILLE, N.C. SHEET NO. DWG, NO, 62O °'^'G'B`" PY•O WATER RESOURCES ICEI ENGINEERING DEPARTMENT DATE: UUIS O1, 253 APPROVEDBY: J.E.G. 2D13-S20 TERMINAL MMHOLEBT.R Know what's below. Call before you dig. z z y ..1 I O Cq LO m 0''.. (V �- •7 � Z •U w "O OA aO o a 00 OU .0 z y C U E O > �i n O O C) vOi U Z M N C Q 1� a) M O -9M U C 6 Lo 2= DO J R Y' O O N J W m } i z LU O J Q`M >'-U M 1) d Z Fp515i� s 4 F%A�AAA'90 1 tASI"Ao`O0``c 11111111141. 111111(. A 0111A THIS DRAWING IS PRELIMINARY, AND NOT FOR CONSTRUCTION, RECORDING PURPOSES OR IMPLEMENTATION. Owner: CBMMPROPERTIESLLC CONTACT: 238 N. MCPHERSON CHURCHRD FAYETFEVILLE, NC28303 PHONE:910-864-1125 FAX-910-864-0938 Project: THE ESTATES OFi GEORGETOWN , PHASE I n 0405-42-0744 tax id A: 0405-52-1954 0405-51-2958 township: Rockfish county: CMTObDIrland state: NC DETAILS CONSTRUCTION DOCUMENTS job no.: P12-096 date: 12/02/ 13 drawn by: PDM survey by: JTR checked by: JAN sheet no.: I C20 ED a N 0 N •�4 11 C Ill. SHERE PERNA. ALL NEEMETER ITERAIS AND MANS DaMX'EO MRMG CONSTRUCTION. THE CONTRACTOR SHALL REPORT IMMEDIATELY ALL WATER B.°0.0551NOA WAIEA MNNOVfAABEW9U WHENEVER IT IB NECESLRV FpiP OVERASEW µ0 LATERAL BREAN9 TXE NAN PHOJ ECCORDANC INTOR TXE CONTRACTOp E..MASTCHAME BE WD WINCHES NELEVATION iXAT.E SCEASEEFTHEWATEAN LSAT EWMIERP EWPTE0.I.WN$AT LA INITIATE IMMENOTE PERATE IN ACCORDANCE WITH PWC STANDARDS LEAST 1B INCXE3A80VETHE ttIP OF THE 6EWEPMVW1AtElW.UHIE&4 LOCAL I CONTRACTOR CONTRACTOR aWW. NOT OPERATE PV WATER Max VALVES WIT MAIN HOUT PNC VJNOITION90R BV¢WERB PREVENTµ 181NCX VERTIGLLSEPANnON-IN MPROVALµD3XNL LVOROINATE AL VKVELYOSING5NiTI1 FWC, WHI°HCAB µlATFPiLBIWLOE NINAG WMNCRMMXAVOSEQUREM DUCTILE IRON IN ALCOfl6W CE W DX R W: gE°UIPEMENS. 2. XWEW�O0. FILE SHALL AVTOTHER METNUOF BLOW WHICH PLUNGE DOMESTIC SLOW OFFFMLONNEDWa DOMEGTICWATERWMNNIXG 3EpMENSdYWGX CCROSMN°WAIq YNA8EY9t WHENEVER IT ISNECE5WYE0RA LEVELS OF CHLO0.IXETO P0.q$THRU RESIDENPS METERS TXE CONDMCTORSWJL -NU... WgTEP MNH TOCR095 UN0EgA8EWEPMVWIATERK PoTIITHEWATERMNN BE RESPONSIBLE FOR ALL DAMAGES RESULTING FROM ALLOWING 'dRtt WATER TO µDTXE BE RMNNMTERLLBH410EDULTIEIRON INPRVflOM'LE WIThI ENTER RESIDENTS PLUNGE NG SYSTEM, SUCH AS WATER NWINS, VANED PAGE REQUIREMENTS. AFUUJOIMOFDUL UlE NPIPESi REIN WED CLOTHING, ROWED SCREENS, ETC. ON THEWATERMVNCENTENEOATTHEIEASEMCR ING. 3. WATERMANSµDIATEg SHALBEINSTAlEDIJIIUZNGARYLMPRWED D. CROBBIXD8NRM DRAX/,DE IJNES: A MINIMUM OF 12 INCHES OF VERNOK CUT -SHEET I"dGTI"G INSTALLATION DEEM. CLEARANCE SXNL BE MN MANED.EME. AWATERUNECPO.S9INGOVERA 6TORMOMU ELINEUNL MDUCTI£IR°NRM ISUEED. INADDITIpN, 4 TRANBFEROFWATERSERNILESSNNLBEAClOMRIBXEOp5Fd1(TVS THREE AND A HALF 05) FEET OF COVER MUST BE MAINTAINED OVER ME 0.1NSTAI,TESTµD3LERIU2E NEW MANAVOUTEXOLS. UlERW45NALLBE WATERMNNORITSNNLBEDUCTGEIRON. IFDUCT9EMONWPEISUSED INSTAI.IM INSIDE RAY UNIE&4 OTHERWISE dRECTED W RVG THEN TWO AS A HKFB5) FEET OF COVER MUST BE WdMNNED OVER THE D TRANSFER EESTING METER TO NEW METER BO%µ°TIE XEWWATER LATERAL WATER MAN AND A MINIMUM W 40.INMES OF VERTICAL CIEAREAR£SHEL BE i°WSTIXG DOMESTICSERWCEUIIUDNOBRA43FRTINGS. SNAEMETER MAIMAXEDBETWEENi EWATF NµOTIESTORMORKWGEUNE AL SE. NUMBER SHNSTNUEDONSJVEMDRESEAOpq CUSTOMER dL'N WXEREAWATERMAINCR°SSESUNOERA510RMORN UNERIEMINIAWM OfFSET'ICEATHOSEEIWONHWSEONLY RMUERN MeN, OFTYELVE(1R)INCHESOFVERTICKSFPOWS14 MMVMANEDµD TPM "WERE THEWRYERMANSHALLBEDUCTILEIRONf ABMµ OFIp EETON 4 AF TERA RASE 'ICESARETR VERREDMO ENEWSTShT18XIROFF VKVE FACXSIDEOFTIECRGSING. ON EN"fi °SYSTEMµOA MNE%ISTNGMN INACLYJR°M'CEWA PNC DETNLS D. CONTRACTORS SUPKYNEWMEMRBOMODSh OFWBNNG METER. 5. WXEN MANISNOTTOSEABµQ0WMNRACT01L8 UNCOJERd =01RATION AT MNN, CLOSE µD RUG WXPoMTONTOMANDON dD SERVICE. B. SEPAMTIONREQUIREMENR A GTEML SSA .°FBE%4RB ATID WATER MAW: WATER MNNS SWJL BE LAID AT LEAST 10 FEET UTERALLY FROM EGSTNG OR PROPOSED SEWER MAIxMTERK,UNLESSLOGLCONDMI SORWRIERSPREVEMAIOSOOT LATESALSEPAROTON-IN WHICH CASE'. 1. ME WATER MVN IS LAID IN SEPARATE TRENCH, WRX THE ELEVATION OF THEBOTTOM OF THEN WATER MANPTIFASi 1BINCIIES MOVEIXEMPOF THE SEW ER MN NAATEML; IXE E MNXIS WD W &BEES IRS WATERMVNEd l MAIEigENG1A4T ONE ONEHEWEEBE ON ABEAREME Ma"MVORBE EART1. ELEVATION BTURBEDE,EQGVUNTITIE EIEV,WEWFT@SOTIMOF ST TBE HEl WATERYAN AT tE$T y ANGLES PB'NETIE TOPOFTIE BPYER MOBNAI£W1 WATER UTILITY NOTES PUBLIC WORKS COMMISSION ND GTE REVlswx FAYETTEVILLE, N.C. 1 UX BS REVISEDNOlEE4 sxEEr No 0W0'N,0 W,' mP=EW: FGEC WATER RESOURCES 2 JUL 11 REV45ED NOTES B ADDSONOTE3 roF: GTE, JutrOtmu aPPRovED eY ENGINEERING DEPARTMENT NOTES: 1. ALL MAT ERIAIS SHALL BE APPROVED BY PAUSEEDNG.WASHTROFRFOR METER BOX LID DENTAI, R. METERG BSHPLL NOi BE LIX✓,TED WHERER, LOA°INOBGNIMPACTBG% ORCOVER 3, FOR 1' WATER LATERAL INSTALLATION SEE RVC.ETNLW3 4 WSLNeURO PLAN i N I I" Ne• ELEVATONO I ELEVATION Oa ELEVATION VIEW 1-INCH METER BOX DETAILS PUBLIC WORKS COMMISSION No TE REVISION FAVETTEVILLE, N.C. 1 aGla cxrNc6pewdMExWaxs SHEETNo. INSTEAD. WA DWO. SF` Pwc WATER RESOURCES rofz DATE: JLILYD1,mi3 M;.Ve Br: LEG. ENGINEERING DEPARTMENT A �y270AD� A u v vC] �I s3w' I O O L r� SECTION"AW PLAN $IM'DROP UD P Ell 4' fi3Y H )j L T 6'naz{ m .11N NOTES: 1. VKVESOSSHALBESPMTYJP-TYPE MANUFACTURED BY RAGE PIPE CO, CHMMPNVNVELO CDCOMBWiIUM MERE GO MOD CO, OR APPROVED ED. IF VALVES°%SHALBESRECECLLEW GRAINED CAST IRON SUP -TYPE VKVE SD% WITH AMINIMUM TNICMIE356M1P. 9. VALVE BOX BNLLLIUVE WBED UTTERED NJATER-CASTINIOCOVE0. VEBO%SXNLXPESH'X dU1LE0 INTO, °NW , N Nl .1 GBO,.HEALL.BUSEEPTO AS"INIMUM12GeLGSINdE STRING COATED.MleRTPPCER WINE DROP LID FORN°N.FERROUSPIRE. Al2WASRER SHALL BE USE °BETWEEN N1RµD IRWOE TIONTENHANOnGRT, S. BLRMMEVALVESMESAPENOT MFR.P.. 6. °IMENSI ONB SHOWN ARE MR INFORMATION ONLYµD VMY BARROMMUHTHE WJIILFACNRER M o-ire' I BOTTOM SECTION 82 TG1N' 8)? TOP SECTION BOTTOM PUBLIC WORKS COMMISSION ND. DATE REVIaM VALVE 80X FAYETTEVILLE, N.C. + + ]m ADDED NGres 2eflawRREGxOTEs N T.6. SHEET UD. °14D- °- WT °M1G'°v PYC WATER RESOURCES 1M1 GTE:NJuw0i. m13 MPRGYEDBY:LBG ENGINEERING DEPARTMENT mle"OVALVEISRJM .-I RVCSTANDMDPEMAGOWE rOPERATING NL?OPEN cauxTEn CLN NOSES NO1ES: 1. RERY°PANI3RNLSEMO°EJS R-RUES' XOZIlESfl 1i1? NOffiE ICI OH MNIJI.G.O °V PSHOURR°C. 'eGr UJUARFAMERIGX... GUIDE W1MFIRE HOSE H NYDWt 00N.DELNAMA)0.°N AGHFIRCHEW21Tr°FfAYETIcMN NDEIlEG3SUALL He SA ON ORAFPROVFDEMJAL aµGRAD. GECURELYCHANE°TOTHE 2, FJLVKVEB µ°HYDPAMSSYWJ. XYOMHTBBOM WNEM.J. CONNECTIONS WITX IRON VKVSW% RETAINING GIANOMJ. NEBTWM 3 FlREHYDRAJTSHASLBEFlm PNNrED BORAB -T ,: IXKCOR°ANCE WITH PRO STµGMPS, BEFORE FROIECTISACCEPIEO - SRCK B'GTEVKVE _ BEE [ONCIiETE TXRUST WOCK I. NY°RWTVKVE 9XALBE FlACEOA4 X DENTAL M09E A9 POS818LE rOTIEMdN.BVi LO '? XOTPLALIx ER°Fa85oM II Es E%IsrlNG CO.cuRB AUDGQWVF .TIE STREETI8801LµDNO PANNG ISTO BE NOFTHE OVALEIISMOSGETERMIEOSYONEAl TIME DTIEHM ' B'D.I. PIPE ... LEI PROJECT CODPdWroR ''. SEE"OTEp4 � S GGERYOXµTS81WLERAOEOAS I - UN°IG pBEO - SOIL BITEEXMWEARTFEE MTMPRGREEVE OIflFCTEO BYTNE RILPRPIFCT CODROURTOR V,µI.ES AS REGOIRED, (WE II. RY°GANTBRAN.SHALNTBEBAG. TMPING DENTAL) FXLE°LWTILINSPELTEDµDNPROVEGSY ] CO T. G] STONE TWOPROJECTMWPMIMIG4 PLACED TO ALEVEL A' J, CORnELTDN WRX IRON MOVEDRANCPEJBNG RETANM ENUMM"RESDIAM ]. GTEVKVEµGeO%SELEAV EIN BEENOTERµDPNL6iAMWO ACC°POANLE WITI PNC SINihNOOETAL PES..'A. DOTAL '.. B. WORANTE%TENBIOW µSIDES OFF $Er89HALISE APPROVED BY RING PROJECT C°°RdNATOR FIRE HYDRANT AND NO. GTE HUMSON VALVE INSTALLATION PUBLIC WORKS COMMISSION e r_s. FAYETTEVILLE, N.C. 1 laavm REMEO xprEw Raft ONG.NQ DWG. BY RVL 2 ]/+,ro REVI&EDNOTER, RE SHEETNo W.13 WATER RESOURCES w TegsD IOF1 GTE: ClJIMPROVE ENGINEERING DEPARTMENT D O O SECTION"B-B" O O L SIDE VIEW FRONT VIEW SECTION'A-A" IRON RETANING..U.'. RETERA 6'R12EBHONNB'fl1r $I UT IRON RETANING GWI° M J. RESTRAIN NOMINAL WEDGES RPE 6ME GVµntt BOLT$ gE36 GUANTTY RATING P E `3re e' + e SSB 17 6 6 35G RESTPNNMJ. JOINT W/AWRG E° RESTRAINT TYPICAL MJ.GTE EWITH APPROVEDAPPROVEDREgEBTPAIM IiVPJ MR NON LENGTH OF RESTRAINT EAM OIREGTONOF TIRLLSL IXUNFMFEETI BW NF.IW8 Pleaeu,N SNW, H.M20:L aNCEDI PIFEµDIML3dI,,$- LMRSPERNl M wn N PIPE VALVES m= 45•ELDNV z3.11r REWLER SRE DFAO ENDS TEES RHON6 eCROSSE6 EIBON6 6' BE GJ S' ]r Itl 1z t0T sr1 24 IZ IHXV N OFFENCE TOE r- RDEeC oPOLRPE RESTRAHED JMMDETNLFORTYRMLTEEINTER9ECRON 4 WAY INTERSECTION SiMI1µLYRESIRMNEO NOTES: 1) THRUSTRESTRANTSUALSE 5) THEMINIMUMLEMIRMPE9TRAM NSTNLEDONDUCTLEIRONWATER INOIGTEO SHALL PEONRENIJOIXR OSTq BUnOXLXESPTHRu1Y WITHINTWENCESiµ AWSE °MMETER IN THENMNERSXOML REBTRNNEO, SEE RYC STANDµO TWURGE &CCK BETNL WII FORPVCREBNWM. Sj REBTWJNi SY51EM8WW. ���pN��NEpp 1 `E"MLN10 OF cL� XEEC nJT 2)IRONRETNNINGGDWOMAREETRUM BEINSPECTEDµOARPROVEO PNCRIUMWENNUMG, B°+E °CcE"' FIPNs1WoOHROM iFORMS T cWGOR BRNLNOBEUB°O"PVCPE )REST--s--- 11E E DI PIPE /R BASED UPON THE ENGINEERS WCTBE 10.°R RP8 3.)PIPE GPFAIEPTWW IRINLR NWIWpE DIAMETERBHNLPEQWRE OSE.NA8NIGUNOiTHE 1. AND PRb6E SHEETS. VKVE, FITTING RESTRAINE°JOIM WPEWRTHE ORDFAD FNO PRIMERIENGTH, E)OPIPPEPRIN.... ➢. 4YOJOP °I PIPE EACTAWE 4.) CMPAGTG7NGBMCFP RESIgANMJ JOINTS WITX IRON )SMµFTµJE CKETSEACC METXODUMPES'IPNMON FORUSEWOH IRONPETNNINGGWHO NJ. RESTRAINT RETANING MLIESTRA TANDOTHERFORMS OULTILEISONPERCON , OUNCE MR) OR OTHER MGM OF OF BEFORE APPROVED DI AESWVM. ALTERNATE PUBLIC WORKS COMMISSION No. GTE REvlslox RESTRAINT DETAIL FAYETTEVILLE, N.C. DUCTILE IRON PIPE ONL 1 +nMzam .14PRITABLE. AODWNTEB sxEErxo °'N° W'TB °NG'ET, °VNC WATER RESOURCES Raft °P1 DAl JUCI'0TSE APPRDEDaY: JEc. ENGINEERING DEPARTMENT THE CONTRACTOR SHALL COMPLETE THE REQUIRED WOBKµD RESTORE WATER SERVICE WITHIN THE GIVEN TIME PERIOD FOR THE OUTSIDE SHgADTHE COSTGCWR FAIL TOCOMPLETETHE WORM W ETHER IXEALLOREp TIMETIIF PUBLICWORKSCOMMIMIONSHA MSEBSAPEM W{ PER15MINUTE INTSR ORµYPoRT1IX ENEOFU"DLWATERSEWCEISRHMNED. THIS PENALTYWILDEDEDUCTEDFi MTHECOMWLdiSPAYAPR/GTIONMBE BILLED OIRECRY RJTNE LONTTI RE EPEXNIY WYBENAMED FOR CIRLUMSLµLEB SPLENDID TXE M. COSTP0., A4 TEEMED BY THE BIJC WOgI(sC... IESIW. THEPYCFAOJECTLYICHOUN 2MUM PROJECT ENGINEER RESERVE THE RIG HIT TO CANCEL OR POSTPONE THE OUTAGE AT ANT' GIVENTIME IFDE EDNECESSPRYY. ONCE THE WATFA OUTAGE NOTIFICATIONS HAVE BEEN ISIEQ AFOLLOW-UP COORDINATIONMEETINGWIMTHEWICp MTNORpINJ,iORµDPRQIECT ENGINEER SHALL BE MEDIA MINIMUM OFN HOW. PRIORTOTHESCHMN EO OUTAGE. THE PURPOSE OF THIS MEETING ISTIEIeFYTWTTIIEC°NRACTOq IS PREPARE OT° PROCEED WITH THE OUTAGE, µOT ATA LE°UIPMENT NATERMI3, MOLE, µD ALL OTHER INCIDENTKSME ONTXEPRWECr31TEAW FUNCTIONING, DEFORA"Y ISOHTPEPUy D.T. lOCOMM1S 1 BEEMSTI NM CONTRACTOR IB XO} pgEPMED, i1C ONAGE sH4LBE POSTPONED µ°NL OIJSttIMEg IMMEDATMYNUTFIEOOFTIECµCELLATON. MEOUTM£SIWLBE PGSTPO"EDA MINIMUM OFTrO UI WEEN3, ROADMOSALCOMRJLTTME WALL BEGRANTE°PORTHIS']ELAV. SHOUL°THECO"TUCi TMEMPIREWRXINTRAT TWO (2) WEEK PERIOD. THE PUBLIC MGM CONVERSION RESERVES THE RIGMM ASSESS LIOUIGTED DAMAGES, AS OUTINED IN THESE C°NiPPLT DOCUMENTS. WATER UTILITY NOTES PUBLIC WORKS COMMISSION FAYETTEVILLE, N.C. T°wc.xp. W,) Dwc. er: PNc WATER RESOURCES x .ATE Jutvo+, m+s APPROVED ar JEG. ENGINEERING DEPARTMENT UNDERSIDE TOP VIEW Ge VEMN ODO�O�O�-o,�0�000�0 0000000000000 000000000000 0000000000000 0 000 00000000 O 00000000000 00000000000 - 0000000000000 000000000000 0000000 0 0 0 0 0 0000000 OOOOOOO WATER YEIER OOOOOOO +a]na• lsme. SIDE VIEW f SOLID LID PUBLIC WORKS COMMISSION Nw °ATE REms1oN 1-INCH METER BOX LID FAYETTEVILLE, N.C. + ]A] REYREDup SHEET Xo. °WG'N0 W4 OVrS SP RYC WATER RESOURCES + CHANGED.°%....1MEHBMs Q°IV DATE: JDty ol.mi3 MPRCVEoer: JEG. ENGINEERING DEPARTMENT l HUM°FRIREINFORIONG D EFORMEORMASSHOWN! . A \ MADEDPoRT...' RWOI&E%P08Ev PLAN REMAINDER IS WRIER M1'8 NOTES: 1. CONCRETEPNOTECFORRINGSHNLBE 25WPSJ.PREGVSTREINFORCEO CCNCRETE 2. VALVE BEEN SHALLSEATGRAOE W,PSOTECTOR RING EMENDING IT ABOVE GRADE 3. SEE GTE VALVEµD SMDETAIL 4. VA. BAY PROTEGTMI WERE GRALL BE INSTALLEG MOUND VALVE BM IN UNPAVED NON TRKFICAEAS. 6XALL N OT CPFATE A HINOERANCE TOLL OPERATIONS, REEPH COMLETE PROTECTOR RING CUTAWAY VIEW SECTION A -A a MTEL VALVE BOX PROTECTOR RING PUBLIC WORKS COMMISSION D. DATE GENNEM). FAYETTEVILLE, N.C. sHETxD °wG. A°' Wg DwG.6r. PNc WATER RESOURCES wF1 Dar Jutrm,xl3 APVRDVEoev: 3E.G, ENGINEERING DEPARTMENT NOTES'. 1.NL6ATERML85NKL 4. BLOW OFF ASSEMBLY NOT BE MPROJEO BYPWC W.FREUSEOUNLESS 2, W,1EN IN6TKLEOINA AFPROVE➢SYPNG. PAVEOMEAMFTERBO% 5. REMOVE ENTIRE ASSEMBLY SHALLBESETIM-AP°VE `ROM BELL OF WATER MAN RNISHEOPAVEMENT ° IPEWHEVEXTENMNGTHE GRAD-ANDPAVEMENT MAN FEATMEREOTOTOPM BOX 3,METERB°%µDVALVE BOX SHALL Be IN ACCORDANCE WITH RM B.I. � SPHNT L I CONCRETE COLLAR- NPAGEDMEAS CMG, PROTECTOR RING IN NM-TPAFFIC MEWS SEE VKVE BO%DEFALWO BWCK_ TGLLIA M.RASSNNNLE� IFMAM WET TAPE, BE DENTAL KVE BO FVC91°ELBITV W.15B WWMP `r aw+ss F.I.PN VA� \ mMr Fogvvc TORE \`1AdVT°R WHEN 'xr A=P csnpoLGAss XIWLE co"cRETE THwsr BLecK Mary 2" BLOW OFF PUBLIC WORKS COMMISSION IN-s. FAYETTEVILLE N.C. J- SHEET ND DWG.xo. yy,i5 owG. Br: Rvc WATER RESOURCES soft GTE: Ju -p1.mn AwgovEo sr: J.Ec. 1 pFt ENGINEERING DEPARTMENT REVISIdI NOTES: S SHALL MJMPLV MIEN THE µCI 1. ALL E%EMS OF JENMF CTCN 6TµTH CES 4RIGINA EAVAONSOFTHS OSHA 06XA REGULATIONS A6''EO'J IREO GeAMANDSEE dU01NAL GRApEANp SEEDED OR F°RCOEE HAPTERµONOF TITLEMCFTICNb MRCON CONSNS TRUCTION'. BELL C-B'MIN. SODDED AB INOMATED MI CONTRON',CNAPIEq%VEA MPE2ACFRPA9T I B26THEOONTRAESCURIALL GVEAnNMONT SELL O='N'1M,•L DRAWINGS. ON BITE ATKLTMEBOUPING E%GVATKIH µOB4CKFlLLING. LLIN 2. CONTRACTOR SHALL USE TRENCH BM SNORING WALL OPEN CUTS IN PANW A Ea6 TRENCH WMTI GALL BE MINTANED ATTHE MINIMUM PWCTMAL WIDTI. DTI =�Jll=III III -III -TIE ESTRENCH C M1WN... AMI EBRUMOF4' 3 OF MOVER MUST BE MAIMNNEO MERE RESTRAINT N%NT -II-I I1-I r 1{ 1=1 PIPE IS SPECIFIED AND SO OF WVER W ALL OTHER LOCATIONS -III R� UNLESS SHOWN OTHERWISE ON TXE, E RE PSOFE - `UNDISTURBED - - 9ML 4. MEMPSULORSELECTMATEWALISDERNED Re'NATNE'SUR.. ATEDFROMTHETRENCH, =_ REMANINGTRENCE B CK FOREIGN MATERML µD FROZEG f COMPACTED TO%%MA%OEN611Y EBE FliO2EN EARTH. ARTH IN MAY. IY LIFTS FOR NONFAWD I-. AREAS. SEE APPLICABLE PAVEMEM 6.BEIONIGATERNL.HALLEXTENO MUN018TURBEp TRENCH III I.� PATCH pTALFORPAVEDARUS, WALLSANOTRENCH BOTTOM. BEDDING MATERUL III WILLNOT BE PAIDFORUNLE88 SPECIFICALLYAPPROVE°BY MEPROIECTREPRE6ENTATTEAND OET Lr� -I11 BACKFILLUKEE roir FOR THEAUTIWREME OUANTTY, - A9pVEPIPEIN6'LIFT6TB% 6 BEDDING NATERAL SHALL BE PROPERLVROODED AMOGNW SITYCESIONLESS6OIL3 AND COMPACTED AROUND THE PIPE W,UNCHEEE SW EIA%DENSI FE C°HESNE 51L8 - III III- ], TEST FOR DENS, OF COMPACTKJN MAV BE MADE AT ME LIT= ICI I: MUCH OF THE ENGINEER AGO DEFICIENCIES SMALL BE III - III- WATER MAN MaERMLSMKL C°RRECFEOBVTMECONTWCTORATNOADDTdY WC l E-l-: L -- BE PS 6PECIFIEOµ05XOWN -' MN TXE 0R4WINGS. TOTHEOWNER THEENGINEFPMAYRAVECOMPACIKIX TEST PEIiFORMEO AFTER THE BACKFILL S COMPLETE. �� 1CL� i- CONTRNOWNSHALLBEREQNREDTO EXGVATET° 4• MIN SUITABLE LOOSE VMIWSELEVAAM SMROENST' SE NGE%GVAp, SML.... EEIF0.0MTIOl BACROLL AND RECOMPACTMN SHALE PERFORMED ATNO CONTNUOU61z G4 �ENCPVATION (SEENCl AODRpNgLC48T8TO TXE CANNER TRAGER WIRE UNDISTURBED REQUIRED FOR 6ML TYPE 3 TRENCH PUBLIC WORKS COMMISSKON REVISION WATER MAIN BEDDING DETAIL FAVETTEVILL M N.C. ESHEETNo. DING. xo. W,Og DZ e, PND WATER RESOURCES 1 OF1 Dael. JULTp+, m13 IAPPROVE JEG, ENGINEERING DEPARTMENT METER BOXIT NOTES: I. WM. FUL.W.,APPRGVF Sr UOCESSEGAMRREPDING SET III ASC EGRADE R. Ge"GELATERLLSPEI'IPS VARJES IT POLYETHYLENE UNLESS OMEMxSO FEE-E, P ¢ SPGOLFED jPAVEM C I- E I. 1' R 3. BE APPR�D BBi` Fwc uwnpx sPN1 L'O"G CJP06G ,m-2 ia¢i 4, WATER S ERVICE LdJ( VALVE TG HE - CLE NLOCAT Orr ST. WX EMII I6TNLED II-L INSµEOIICH. 5. WHEN NETALLEDI NAPAVE°ABEA, METER BMW BE SET1/r ABC E 1'FULL PORT NIGtE flat VKVE PAWFINISXW RIEU MENTGPIDESµD GWiFD FORTWDSTERSIVLE J II TO PROVIDE OPAINAWAY°fA°MCP BO%B0% f CW PRESSION FOR Me RE INSET ^ - - 1'LC9NGL£ µpfEMALE METERMRUO -11- T-iT�n B. �,L M ETERBO%ESSHNLBEUSED I§n BTNNLE658R6 gyry. NUT WI M LE ALL T FlCµAVREEW48. SETUP SAq.LE IN8ERi38N.UL BE STAINLESS IS METER WUFVXG ] PERIMETERSd.I000NCRETEWICK STEEL WITXY'FEMµE 9q C%WON PIPE. SEE INSET-1 NAL_W P°RATIONGIOP TEE EAO METERSWIVEL 'MTNAWWAINLEW ONE NUT %X'MIPT e. WXEREMPRLLTCOPBORSRP OR TWO STEPETIOLE, PAEMENTEAST, TNIF OGTIONOF Cp4PREB810X FpEIK F£, 'v]-IQ'SIMCER ON BON SHALL BE AS DIRECTED BY HAD 'MTHSTIRLf93STEEL Me. SEANCE, REPRFSENUE INSERTS. C'Ov1Dy4'SPA FWV B. DISTANCE FROM TOPOFLCCKVKVE I.' ILERS IMCE, OPERATING STEM TO TOP OF SEE p'IPS POLYETHYLENE POPE SPACER SHALL BE SHALLBEB'MIH.WIPMA% E 34E 1 W PBIP E. N® FURNISHED BYH4L, R E P31 ASTM 01246TYPE III 10. flF51OENTIK METER BOXSMVLBE SET ASTMD3TSO3S5+34C SEEINSETER BO%B\SE S'FRMESOMMCEREEPLINEOF WMNN SEE INSET•A' METER BO%PERPENCOULMTO TIE HAS O%ME T CCg°C MTIGIORNO.B5X1N1A.L BES WE TRACER PREFER NO METER SAESIAN PG. PARUOVEE°WWG..TTO C°P°PpT°N°g8M'°SL EFIENINTO ME FROM OMOEWpE B-AND NUB CESME µOUNDLOCKWELVE 1e' 12. UTERI`SHALL BE COSTEREO r SOLIBMICKMETER BOXGS£ ON LOT UNLESS OTHERWISE NOTED, EO EG 13 LATERAL SHALL NOT BE PACK LL BACK FILLED UNTIL INSPECTED BY METES_ BDTTW O FNCPROJECTCCM,1RMCl F1 _1 14. ATERMAN µDLATERKSHNLPASS HYDROSTATI C, LFMADE µD BRICI( _ OF WX STERILIUTO" TESTS I. FBI) 11 -1 yJl 15. ACCEPTABLE ME NOT SECUDER., BEATER CENTERED SE 18. SHOULD IT B E NECESSARY TO CHAIR THE BRICK METER T "A IMETFA Po,Y REPGEATAIPCERVICE LAMHSWVLTEBE:L.•FGE°°NT�F¢ I N SET 'A" PLAN PROPOSED I"WATER SERVICE LATERAL PUBLIC WORKS COMMISSION x0. CAT RxsroN FAYETTEVILLE, N.C. R 1 IMV OS KECXM'GE SHEET No. c. xo. W2 owc. BY'. W. WATER RESOURCES r 2 sEPrm VALVE CHERGE ADO NOTE 1e. 1 oF1 DATE'. Juao+, m+3 E7V'D Br: J. EG. ENGINEERING DEPARTMENT NLYW RESEED METER CURING NOTES: 1. ALL MATERMLS SHALL BE IN ACCORDANCE WITH ME SOMBREROS. 2. RESILIEM WEpGEGAIE VALVE GH4LL BEA6 µUFACTUISD Bf MUELLER CORP., AMERICAN DARLING OR CLON CORP. 3. ALL VALVES SHALL HAVE 2-SQUARE QW. OPERATING NUTµO sMALLOPEN L OUNTERCLOCKWIE. 4. VALVEBSCNGEEMETH GATE 511ALlB AEACC00.GXCE WITH AWNACWBCfi15 µLYE BODY O 5. VMVEBOOYµ6TERIOR SHA LLBE CGTEOON IF INFERIOR ANOOWRATEREOR ENT SURFACES WIFE A ITNFUSIONAR BONDED E IN ACCORDµ CFND S AWWA SHALL H B. ALL VALVES WOWING P ESSU E OF ELSE HAVE PGFE WORKING PRESSURE OF R59 PAL ]. SEE FOeNAESOX OETALFORAoorzrcWAL INFORMATION. B. BE VALVE BO%PPOTECTCR RING OUML FOR ADDITIONAL INFORMATION, E BON SEOTIDRSALE HE WIRE°. THE USE OFv RE P' LEu oFVALVE eO% SECTIONS SHALL NOT BE. PERMITTED. VALVE IN TRAFFIC AREA VALVE IN NON -TRAFFIC AREA GATE VALVE PUBUGWORKSCOM MISSION IFC1 GATE REVWIO" INTS) FAYETTEVILLE, N.C. 1 SAS OSOMEREw snEor no. °L`T'N0' W'S DINNE Eva WATER RESOURCES 2 ]AB MMTSO NOTES DATE JULTGLm13 µPROVe;BV ,EO. ENGINEERING DEPARTMENT 2015W8GOTEVA r S°. 1.1 d'$Q NOTES. NLMATERIAL9$BALLBEWGCCOHOM'CEM11-1 THEWOR°'OPEWANO PNC 6iµGRES. THROW INDICATING COUNTER 2' P(J SEND RAKE FPLE 6HALLBE REIN P.UrO PgON CE DIRECT OX GSTXERE FO0. PROPE0.PLGHMEM O. iXETO➢RXG SLEEVE ALVES SH,VL HAVE 2' SCOA¢EOPEPATNG NUT µOSRALL °PEN LOVNIENCLOGNAfiE. 4. RESUE"TWEDGEGATEVKVECEFFER 3 IMNUFACTU M ELLERCORP„MERGN -S=NO. A612 . DARLNG C.WE ONµPRCED EQUAL HMBGSR� RL (1]SF ) - - _ VKVEC0mW ANOGATESHaLSFIN s. ACCOROARCEWITIAKWACSpYLSISAND RESSE, 9. VALNEEDDYANOBONHETSNKL6ECGTWONNL IHlE0.1 MTµ°F <6NITHAFUSgN IN ACOR GAING1 FOR... EPOM IN MFW6WCE WIiN 1VM'A ING". AM E6 N' µCI SMAll�RSHALL PAVEpSAFE y WOP%HG PRE9WPE OF2m3. `?�O RL Imp O' a Old APFNGSLEEEIDETNLSWtp NivV.t1)FOR AOOT Dx4 NFpgWTOX. SI ' DIMENSI°N6SROwNAREFMREFERENCEµD Mgr T VMY BASEDUPONMµUFACTU FR. VALVESSWJL 6E SIMILAR IN NANRE TD'MTSMOWN pVD9HHA NOT DEVIATE IN E$sENTLE DETAILS. - - 10. All TAPPING SLEEVES SHALL E HIDRWTATCNII C G-NO. A512E OF PRESSURE TESTED N ACC°RdWCE MTI MAC SPECIFICATIONS, TEST 6HALLBE NIT WICEOµD BDLi yOiB APPROVED BY PALL PROJECT CfgRDNGUN PP UV TOB GNNNG TAFF.. PROCESS. V i T 40S RT Ig ZE A B I C J K L NJ 111 N R 6 OVEx_ WEIGM Al. i S]9 1 e 4..1. 2In i-Il2 B - I4 EG $ -TG It6 6 6] B1w 1 11 IF- nso-1]-My4 ] All v 1a - D/otr1Q 11 12.]/1fi 1-] .111 3-IQ ]1.Yi F�1.iN�]31Q X.19 161111 SDI 39 54.__ 'IB 31� TAPPING VALVE PUBLIC WORKS COMMISSION NI Gas REVISION ]ros ADo6o NOTE ICI RENssp4fls (POTS) FAYETTEVILLE, N.C. sEETxG OUG. ND. W,g TTNc ar: PWc WATERRESOURCES J1 E ]ITS RENGEDHOlE64, 6, 1G 1 GF1 GTE: N,,, mlG APPRDVEOBY: J.EG ENGINEERING DEPARTMENT m 13WB M l TAPPING VKYE,q CONCRETE CHUG IN CONCRETE CW PAVEOµEISCOXC. AVEOAREa50 NROTEOTOGRE °WTPI .µEIS ASPNKT� XOOTECTO0.RIN H.TRARE. (SEE VINE SO L Y min ® (SEE % 'Al-ve / DETAIL" .]) FIRACG'RRE-I DENTAL W D RANGE -COMPALIFDGOR(TM) COMPACTED soR(iYPI VANSUSLE EMERUG TAPPEDY SLOTTEOVKEEO% FITTSONTOPCFYPIR Fi60EDTOPOFrB°PIPE B LK TOBEFIALEDIINOER"PE N ON TD BE RACED LINGER PIPE Y PVC SURE, WATER PIPE -I'D V.NGBM53NIPPLE. 2'SMSSG PrPALKJ01a WL 0.INIOR WREN ftE0WRE0RPE 0EYON0 PASS N PPLESWVLPESCHBI zOR 0 SPA99 NIPRE(1rj WL.M.ELTEGw/.MSS F I P, R'B BRSS A.. VALVE v PAG JOINT MR PVC YD °V58.'M.UY) AMR,G TO BLAME &VL VALE VAWABLE S 2E WAIEi MAN r0BPP55HUMPL 12) RRACHIMNT F00.P�VCSFA➢Ot 2' MAIN LINE VALVE VARIABLE SRE MAIN LINE TAPPED 2 2" VALVE INSTALLATION PUBLIC WORKS COMMISSION CO N0. DATE RI:VI610N ("TSJ FAYETTEVILLE, N.C. Sae ADosD xars GN Wxc. couaa SXEEi uD. °14G NO W i5A °'"°"` P'I'L WATER RESOURCES � 1M1 GTE: JWV0Im13 MPROEoer: JEG ENGINEERING DEPARTMENT A13 WISA2 VA-.IN.FAUWU N.ewe FOR TWO (2) INCH FIRE LINES AND DOMESTIC SERVICE W%Y'TAPPIN65 ME rBPrLLVgq �1,\ 1.V MWATOR %2•TAPPINGSAWLE Wrr BALLVrLLVE NOTES: IUOMESTC BA:RLOW MU SGUWAMD INSIDE THE BUILDING. 2.IN FIRE uNE SNNLXAEA BACNFLOW DEVICE WITHIN 1m FEETGF THE MIN. 3. REFER LO THE CFOSSCONNECTIOX CONIIEb. ORGINATCE FORADDITONALNFOGMATION ON EAMFLOW REGUIREMEHIS. FOR GREATER THAN TWO (2) INCH FIRE LINES AND DOMESTIC SERVICE TAP PIN°SLEEEANOVKVE -%_TEE WIMGTE VALE STANDARD TAPS PUBLIC WORKS COMMISSION aFVIsroN FAYETTEVBIE,N.C. snEET NO. ;nNO Wyi Dva.BY: Arc WATER RESOURCES roF1 ENGINEERING DEPARTMENT DATE: mtr 01.z0n APPROVED Ev: JEc. T� 4•3W21 STANDARD TµSQp _._ NOTES: NOMINAL PIPE BRANCH SEE ATgd(. W! 169. 1. NL MATEPJN591MLLBE IN ACLARDANCE WITH iMC3FµGRDS $R IN R. TAPPING 9L£EE95WELBEA9 MMIUFACIUgEDGf ROA+AC BMITN.BWR, OP APNRIED EOVAL P %THIS "'Al - i 9TNHLFSt SIEELTMPING$EEE tyV BE (RIU2Ep FOHALL HeRM4B 8'Y 'B'1P Fe 4840.Sm TAPMNGOFMAWUPTOµDINPMNOA'pAMETERW7HlZ ;P z •r '. M,91 ORLEBBdUNCH. BRMJCHGREATERT14WIrSNLL.Q.1iE i6• B.4 d. T NE .., es lm lls.irz F°LLBO°YOLM,L IMINGSLEEVE (BEEOETAt WIm. N' Rlr B]BltIN1 � SHELL A"° LOGS SHALL BE STAINLESS STEEL PER. AM OFF SI CV ANS. PER. m4AND mM. DRILLING FLANGE. d FL E roPRoiT BBOT$ $NA L BE RUNC HO LLPIEPDE TSHZ0.FLDRL BruMxV N AMA19TPE64OM. MI,T10T CM'PPER, 6. HOT88H4LL BE XFAW XEXSTANlF865TEBLFER JSMAIM.TYPE W4. T. WISHEXS SNALLaE SEELAND PLAsnc LLBNrwmJGwpsHFx TEST RIJG 9X¢L 8 GMl(EIS RW.LBf VIRGIN SBq FERABIM° RAA 810. COMPCUNDPOFORWATERANDBEWERSER/ICE SCUTS FLANK CSHALL 8 E DUCTILE IRON OPEN MIN BW, G PACE flYS12 OR GTIX EEL PER ASIM A-R4D, lYPE3p4. FALL EPFM'g1 NUTS 10...... I......N µEFORPEPERENCEµDMAIEVARY. �Y,UEMj UPON MANUFACTERER. SLEEVES SHE REPER 41XIN1WEl0 THAT SHOWN AND SHALL NOT DEVIATE IN ESFHJRFL M ABS - 11. PEPESIMFACES SEE BE CLEANED THMMMIGHLV TO MERE �} GOOD SfK MIGN TO INnN3wnpN. 12. ALTM'ING SLEEVES SHNLBE MDRW ATMNLY FPF� AGMIXS- TESTED IN ACCORDANCE WITH WE SPEOFIGT°W. rESr$HLLL BE IORNEBBE° µD APPROVED °Y PWL PPOIELT C W TmI1NTOR PRIOR TO BEGINN LNG TAFPWG Rd.CE88. 13. THE NUMBEROFWLT6.NU1sµDWAWERBBN°WNAREFOR ILLUSTRATION ONLY, ACTUAL QUANTITY 81ALL- BE AS WASHERS gECDMMEERI THE SLEEVE Mµ11FOCRpERFMi TIE REOUIREDSERNCE, UFTERSN 14. SEE DETAILS We AND W 17 FOR ADDITIONAL, gEMflREMEVE STAINLESS EEL TAPPING SLEEVE PUBLIC WORKS COMMISSION No. GTE REVI6M N.T9 FAYETTEVILLE, N.O. I TOE pfD NOrss z, YaaAaFlFnnolEs SHEET No. DNG NO. W.11 OVIG.Br. WF WATER RESOURCES 2 'D EVIBEDWTSESDG t OP1 DATE: JDtrm, ml3 MPRwED ar: J.EG ENGINEERING DEPARTMENT XW.TRAFFIC µFAR. (SEEEE EBOt WLA W]) I TAPPING SVME `Y T2 EME+PIPE t' BM$$ F I P. a PK%JMN MRFVCAOVIOq YOB'BWSSNIPRE tt SBTARPING SLEE VARIABLE SIZE MAIN LINE W/ 2"TAPPING SADDLE & BALL VALVE uD. G E PUBLIC WORK REWSIo AP S COMMISSION 2' WETT FAVETTEVILLE N.C. A� RATS) , �y 1 bID MDW NDIEOXCONGPEIE CCUAR sHFIVO IBM. PO. W.'15B 111UNGE: RWC WATER RESOURCES 2 vm R6vEED VKEL➢rwnoN DATE. JNtYpLm13 APPROVED Sr: JEG ENGINEERING DEPARTMENT PRELIMINARY DO NOT USE FOR CONSTRUCTION mm"ON R WETT (TYPICAL FIRE HYDRANTS CONNECTED TO E 06TING WATER WINS PROPOSE.GeEXYDRAMS..NEINRTNIEDINA°V%JJLEOF.F 1. EAS WVKEUKX MEMEA9IJREDFg MW9TINGASPWLT R MANCON8TRUCTON. THECOMR4CT0R9H SMU.ML EM'OPANT VKVECWFRTOTIETOPOFTHE OPERATING NUf THEO EINF TON IXBTAUAT°H TOPRONpEµP'OR SUPREMEM WAIERNAMFlAI3HING lF 9XIXYN I9 GICUUTED ISIXGµINTERR%ATONBETYEF,NIXENN egFAK9 COM, NFMWTVKVES. TREGWUNDEUNANMJAJMRCURQMNTNEPROPJ$END FIRE HYDRANT IS INTERPO W ED FROM CRO88 9EVTOXB AVp THE F W JGE 2 FIRE Me ANTOONNECUONSTO Ea3TW WATERLWW9IWLSEMACE ELEVATION&1p1VN19MPR0%IXATE. FIRE MLPAK SNALLBEIKSiW1EDIH MNGATAPPINGSIEEVEMDVKVEBVWETTMCONNELTQY THETMPING ACCOPDA"CEWITHTNE FIRE LOGRANTAW VKVE INSTALLATION WDS!, SLEEVEµ°VKVESIWLBEXY°POSTATCNLYT6RTEpRMOR E COMPLETION OF THE TAP IN THE R✓ESF MCF THE OWNER 0. TE'ANTMCTORSNNL 9UB8LITITE VANM130WRELCEPIIS WTIIN ME RECVECT E XYDORAWIDN tXK l- OFSA .Mp W THE CCMMCTORSEDOREETERANTPTX°°IIUTIESLOLFDINTHE MMT WNMTTESAV4'DE I PNORTOREWESIIXG Ea AP-0'OEPTH OF BURY ACTUKCONDITOXBREWIREAPQDFPIX HOFBUW,L° COFBUgY,NREl%AYFDE CONITY°FTNEPROES CON3TRUCM1MV9TEANEHEPROF09EO1PGTIONIMYBE9X THEIRE POSBO OF.0 OFBURY,TXD" BE REOWREOl ALLEX1EH910X BYTHF OWNER IF LONGUCTS EABi (IE. Gi48ERNOES.VGE ME9TTVT JEAN M.UG TIE OECTC00R°IXAT°RE UATON ON TELMATED AND DIROVEOBY TELEPHONE ETc.4 ANOOxty AFTER ALL EFFORTS OF suBSTN110NAgEEA1WI8lEp. EFFORTS EXHAUSTED 4. THE COMNAC °RSHNLVEq% OGGIN INAGVµCEOF 9. WX EIN (BY G1. EA OIGTEDNTIE E%ISTNG FINE XYORAHt1p NEVIMAIN PROLUgEMEM,TIE EMSTNG WPTE0.MEN CONTRAS (OR 9XNLMWI OENILABOR TOOIi.EW RJEXT W TERIA3 MEATE1ATIONµOMPTERML gLE3 CM900EPM µOLOGTOH FMEGALX INGMOI,BARE ETC. R[ GARY Tp FWVIOEA COMPLETE INBTNUICM FlPERYDPANT eeIR ttINEW OgµCX HYDRANTANDTHEI ACCEHTEOGENUU. 9IFEVETYPE6BNREL 9WLLL BETSHENT REQUEED MATEPLVPROFEA B SERVICE GREMETHANA FASTING MERGCONTRACTING ITINGSH OTBE°VTES SERVICEFOR RIWJINXFOE WVNWSµNCOUNRED.GEMTERAL3T°.VSAMAOMIE MPIEgIAL$EMCOVNIEREDµpsITECOHDRIOXS WXTUCFOR BNNL NOTIFY IXEAPPRORIMTEF gEpFPARTMFM601R°F FIRE SERVICE Fl RE NYI3MNT9 PNdE TO CGSTIiUC110N. 6 THEN"WRMATION CONTAINED IN TIE TIFEM9RN4T GTE GENE WAS PRODUCED JSINGMSnNGRVCREO° MDAVALOBLEFIEU) UE SWSx4LSEGEPIACEDW16REµFEIGHLEWMGETOPROPERK INFORMATION. THEN NFORMATIMISIFRENOEDTD/SlV3 EMNRRACTOR OWNERSWMCARING.MWES,MSWV MWPNMDORRERAL M BUTSGVARµTEEF THECOMRACTORRENCOURA°EDTOVERRIFEAL TIEFNOPERTVM]MEYSGTISF TIM,MINdJIDEWITFIINRGM-0FWAY, TXEPRONDEOIVMRN l TX181NMRM4T CN 19 MPFOAMAIENA WY NO SEPARATE PAVEMENT), "OTBEACCUMTE. e, THELAMMLttJR WILL BE gEOU REp iO3UPRY VARIW3LT.WM40F BARRELSµ0"WRIGHT B"U NRON6(NOMBGETVUNOVE MLNAT UPTIN91ON IMXY Y BE USED PER DRµn D T ADJUST.. WATER MUN°EPOS IN AOTOIPOF FZSTINGCURMADE.NOR OF PAVEMENT, EGEIGNS BEECH GRACE MOOR q GWGROUND PREMIUM AS NW ADDITIONAL FIGUNIGR HERECURENT ENTENdON90ROFFSET WNNECTOS MYBER°NRDOMWNNPROPERPRDTTE0. PROJELTCOOgDIMNR NOSFPNMTEPABIL FIRE HYDRANT PUBLIC WORKS COMMISSION .D GTE REVJRM ADDITIONAL GENERAL NOTES FAYETTEVILLE, N.C. 1 ]Aa REPT9E.nOlES2i a BR SHEET ND. °WG'XO' W.12 °"G'B1' P°E WATER RESOURCES 1 aF1 GTE: mIGH.m13 MvgDYEDm: J.EG. ENGINEERING DEPARTMENT m 13WIEFHNOTNS MIN. BFAPoNG MFA EACH dNELTION M TWUST W &LLMRE FEET (DeM on mn wppewg'I+IIe m m0G ql ®m0 Taq Mu W eevval PIPE TEE W° 'ELBDY! RR-Il SME LEMEEE ELSON9 .CROSSES DOWNS 9• ] 10 9 8 I. TIZBT SWED. SE SE IN METALO THE` WATEPOISTUBUTION HES MC 1I N111YO1A TNELWINEABSXOWH. BEENRVOSTAFORAC KT REESWN MTIL ERM MINI fA01E KIEPNATE RE3LRAINIM08YS1EM5. R. PIPEGREATEATHµ121NCH Ir 15 31 11 6 DIAMETER BRLLLREOUIIiERR41WVNT JOIN PIPE FORTE PROPER LENGTH. i COMPAGTEITENGSµENT RO .THCaN �DI9TEE0 ACCEPTABLE SFMMFITTINGS ELBOW Ell MFAOF T"SW9TEEWL G°N°PETE SOME 4, THWSTBLW'x88W LL0E NSTALLEOONBFJYERFORGE MAN INTEMAINFABNGWT. - SIFSACM 1SWEn,MDRNG SEE&WI-0FFDEFNLMEN MUST BOON SRE Ui11YING A CIMIFlGnMJOFCOWLRUL0M1 ELBOVJ MEGiWBGLMDER T RE°dREDATCEA MENDS 6 NOCONLflEIESHALSE PIACEO°x BOLTS. WRAP HORIZONTAL BEND DEAD END JOINTRTTNS.SeTHERWORO T CONCRETE SHALL BE MARINE 3,NED E. BE E%GVATINNS S. ALLBEMINGSUISMESSHALLSE SIDE EYGVATpN3(IYP.) TdP,) AGKNSTINDISNPBEDSOIL AND COUR_ SIW.EDINAG I REEL BYRYCP0.0J M CCERNATdtPPo0RT0 %ACEMFM OFMtXMiEIE. fl LISE OF REerRNNED JOIMWCTILE IRCMWILLBEREOU1eM FWH ...MER, DONOTALLONME LLBE _ OFTXWIBi YOCNS. tU.ALL V6Y11GLBEM1O$SNMLBE RE8RWNED IISWGPESIRNXED �CMNOE'F JOINTMECTREIRONRPE. ALL SCENE E1W.LE FFT VVV ALL EVEE] CLEARS PIPE SILALBEAGaWT Jot"1vT-P.) TAPPING SLEEVE TEE uX°wroPBPO CROSS AND VALVE °RWND(MR) PIN E ORAL MIS RE don CONCRETE THRUST B LOCK DETAIL PUBLICAN ANSCOM SION xrs. FAVEITEVILLE, N.C. 1 Evros FEVIEOTADE SHEET NO. °NG'HO' W'TT °+Y°'Br: w+c WATER RESOURCES E z G] °END Noresealo 1 aFt DATE: JULYG,A13 JAPPRECREMBY. JE.G.1 ENGINEERING DEPARTMENT AL zolswnmftuBremcKe.P rCONCEPTUAL PLAN ONLY THIS DRAWING IS NOT A CERTIFIED SURVEY AND NO RELIANCE MAY BE PLACED IN ITS ACCURACY. THIS DRAWING HAS NOT BEEN REVIEWED BY ANY GOVERNMENTAL AGENCY FOR COMPLIANCE WITH ANY APPLICABLE LAND DEVELOPMENT OR OTHER REGULATIONS. EXISTING INFORMATION IS BASED ON CUMBERLAND COUNTY G.I.S. DATA. Know what's beilm Call before you dig. z , N O LO p[ OeMO z BE, W Do Iq 9 c •�% yI GO { ry V " W z � h a I�L`U -J C) it O 00 L C z Y X V W O> O � E DO L ir M T z W a C) M O d Z n-•OUSMIIIIIIIINy/4A.- ` ` Ali 111 `\ P/ \ s EE ry !i Y9' v� = SEAL c 0314rg = rn nNSaT"``�`\`�0`0� Ism, 11 THIS DRAWING IS PRELIMINARY, AND NOT FOR CONSTRUCTION, RECORDING PURPOSES OR IMPLEMENTATION. rz 0 .y m _d a C3 0 Z Owner: CBMMPROPERTIES LLC 0 CONTACT: 238 N MCPHERSON CHURCHRD FAYEITEVILLE, NC 28303 PHONE:910-864-1125 FAX •910-864-0938 Project: THE ESTATES OF GEORGETOWN PHASE 1 0405-42-0744 tax id #: 0405-52-1954 0405-51-2958 township: Rol county: Cumberland state: NC DETAILS CONSTRUCTION DOCUMENTS job no.: P12-096 J date: 12/02/ 13 drawn by: PDM survey by: JTR checked by: JAN sheet no.: C21 G. PURPOSE To temponsrity stabilize denuded areas that will not be bought to final grade for a period of more than 21 calendar days. Temporary seeding conbols run off and erosion unlit permanent vegetation or other erosion Control mmsures can be established. In addition, it rovides, residue for soil protection and P seedbed reaan end reduces problems of mud and dust production from bare soil preps P surfaces during construction. SPECIFICATIONS Complete grading before preparing seedbeds and install all necessary erosion Control practical such as dikes, waterways and basins. Minimize sleep slopes because they make seedbed re ration difficult and increase the erosion hazard. If soils became Compacted P Da Pase during grading, loosen them to a depth of 6 - 8 inches using a ripper, harrow or chisel plow. Liming -Apply time according he soil test recommendations. If the pH of the soil is not known, an application of ground agricufturel limestone at the rate of 1 to I Y2 tonslacre on coarseetextured soils and 2.3 tons/acre on fine-te and soils is usually sufficient. Apply limestone uniformly and ocawmete into the top 4.6 inches of sail. Soils with a pH of 6 or higher need not be limed. F nilbuer-Base application rates on soil tests. When these are not Possible, a a 10-10-10 e PP Pos axer grade fertilizer e a 700.l. Il hyacre rate. Boca fertilizer and lime should n Incorporated info 4 inches of soil. If a hydraulic seeder is used do not mix seed and fertilizer more than 6 t es P Yd than 30 minutes before application. PP Surfaces roughening-lf recent allege operations have resulted in a loose surface, additional roughening may not be required except to break up large clods. If rainfall causes the surtace to become sealed or crusted, loosen it just prior to seeding by disking, raking, harrowing, or other suitable methods. Groove or furrow slopes steeper than 3:1 on the Contour before seeding. PLANT SELECTION Select an appropriate species or species mixture from seeding tables at right. SEEDING Evenly apply seed using a cyclone seeder (broadcast) drill, cuMpacker seeder or hydromeder. Use seeding rates given in tables at night. Broadcast seeding and In area appropriate for ale stop" where equipment cannot be driven. Hand h roseetl eq p Yd 9 Poop P D broadcasting Is not recommended because of me difficulty in achieving a uniform distribution. Small grains should be planted no more than 1 inch deep, and grasses and legumes no morethan Y22 inch. Bmaticastseed must be Covered by raking or chain dragging and men lightly finned with a roller or cultipacker. Hydro ayeamd mixtures ahouid include a wood fiber mulch. MULCHING The use of an appropriate mulch will help ensure establishment under normal Conditions and is essential to seeding aucuss under harsh site Conditions. Harsh site condition include: aeetling in fall for Winter Cover (wood fiber mulches are not considered adequate for this use) -slower steeper man 3:1 aba estuary hot or dry weather adverse soils (shallow, rocky, or high in day or sand) areas receiving concentrated Row If the area to be mulched is subject to Concentrated Water flow, as in channels, anchor mulch with netting. MAINTENANCE Reseed and mulch areas Where seedling emergence is poor, or where erosion occurs, as soon as possible. Do not mow. Protect from More as much as possible. REFERENCE: NC Erosion and Sediment Control Planning and Design Manual - Practice 6.10 SEEDING MIXTURE: Rye rain-1201b/aces Annual Les daza-50Itimcre -Omit annual leapedeza when tlureron of temporary cover is not to extend beyond June SEEDING DATES Mountains - above 2500 ft.: Feb. 15 - May 15 below 2500 ft: Feb. 1 - May 1 Peidment - Jan. 1 -May 1 Coastal Plain - Dec. 1 -Apr. 15 SOIL AMENDMENTS Follow recommendations of Boil test or apply 2000 la/acre ground agdcultuml limestone and 7501amore 10-10-10le tilimr. MULCH Apply 4000 IWacre straw. Anchor straw by tacking with asphalt, noting or a mulch anchoring tool. A disk with blades set neatY straight ht can be used as a mulchingtool. MAINTENANCE Refer lize ff growth is not full adequate. Reseed referalize and mulch immediately followin erosion or g Y q Y g other damage. TEMPORARY SEEDING RECOMMENDATIONS FOR FALL SEEDING MIXTURE: Rye (grain) -120lb/acre SEEDING DATES Mountains -Aug. 15 - Dec. 15 PeidmoM-Aug. 15. Dec. 30 Coastal Plain - Aug. 15-Dec. 30 SOIL AMENDMENTS Follow mcammendations of soil test or apply 2000 gainers gmund agricultural limestone and 750 IWaore 10AM-10 fertilizer. MULCH Apply 4000Iblade strew. Anchor straw by facdng With asphalt, netting or a mulch anchoring tool. A disk with blades set nary straight can be used as a mulching tool. MAINTENANCE n rtilize damaged areas immediately. To iess with 50lb/acre M Muni in March. If it is Repair and Pa 9Pd necessary to axlerid temporary ry ground over beyond June 15 overseetl with SO Ib/aae Lea edeze in late February or early Maroh. TEMPORARY SEEDING RECOMMENDATIONS FOR SUMMER SEEDING MIXTURE: German Millet - 401b/acre SEEDING DATES Mountains - May 15 - Aug. 15 Peidmonl - May 1 -Aug. 1 Coastal Plain -Apr. 15. Aug. 15 SOILAMENDMENTS Follow recommendations of soil test or apply 2000 l acre ground agricultural limestone and 750 this= 10.10-10 fertilizer. MULCH Apply 400010/acre straw. Anchor straw by tacking wilt asphalt, netting or a mulch anchoring fool. A disk with Wades act nearly straight can be used as a mulching fool. MAINTENANCE Radia line if growth is not fully adequate. Reseed, radial and mulct immediately following emdon or other damage. REFERENCE - NC Erosion and Sedimentabon Cordral Planning and Design Manual -Tables 6.1 Oa, 6.10b 6.10c. 19-gauge hardware NCDOT#5 or#. % washed stone clofirl mesh openings) I 5'steel posts W rieddmum spocing�l /J El I I. NCDOT#5 or #5 11 1 Washed stone I CONSTRUCTION SPECIFICATIONS • N 1. Uniform) grade a shallow depression approaching Y - the inlet. s 2. Dave steel oats 2 feet into the P Shouted surrounding the inlet. Space posts evenly around the inn t M1` 27 perimeter of the inlet, a modmum of 4 feet apart. d 3. Surround the posts with vim mesh hardware cloth. Secure the wire mesh to the posts of the top. middle and bottom. Placing a 2-tcat flap of the wire mesh under the gravel for anchoring is recommended. 4. Place clean gravel (NCDOT #5 or #57) on a 2:1 N slope with a height of 16 inches around the wire, and smooth to an even grade. 5. Once the contributing drainage area has been stabilUed. remove accumdated sediment dispose of properly and establish final grading elevations. 6. Compact the area properly and stabilize with altered groundcover. Water MAINTENANCE Inspect inlets at;aost weeki and otter each significant V inch or greater] rainfall event. Clear the Hardware Cloth & Gravel Inlet Protection mesh Wire any debris other obledstoprovide flow adequate row for subsequent cabs. Take care notto nt damage or undercut !re wire mesh coding sediment Reference: NC Erosion and Sedimentation Control Planning and Design Manual- Practice 6.51 removal. Replace stone as needed. ROCK BAG ROCK BAG/ TUBE OR CURB INLET DRAIN FILTER INSTALLATION GENERAL. INSTALLATION REQUIREMENTS: (SEE INDIVIDUAL MANUFACTURERS FOR DETAILS INSTALLATION INSTRI1CM) • INSTALL THE INLET PROTECTION AS SHOWN ABOVE. EACH END OF THE TUBE SHOULD BE SECURED AT BACK OF BASIN. • THE TUBE SHOULD BE CLEANED IF A VISUAL INSPECTION SHOWS SILT AND DEBRIS BUILD UP AROUND THE TUBE. • TO REMOVE THE TUBE. LIFT OUT OF THE OPENING. ROCK 9AG/SEDIMENT FILTERING BAG SPECIFICATIONS BAG MATERIAL: HIGH .DENSITY POLYETHYLENE -COVERING FIBER MATRIX BLANKET INTERIOR RROpC�K_ 3/8 PEA GRAVEL WEIGHT (DRY) 30 LESS ••USE A PPOWER WASHER OR STRONG HOSE FOR CLEANING -- FLOW TEST RESULTS: FREE FLOW WATER (NO DEBRIS) 30 GPM SAND 29 GPM TOP SOIL 28 GPM CLAY 24 GPM EXAMPLES OF ROCK BAGS: ROCSOC BY MARATHON MATERIAL, INC. SILT SIFTER BY POLLUTON SOLUTIONS, INC. EXAMPLE(S) OF CURB INLET FILTRATION TUBE GUTTERBUDDY BY ACF ENNRONMENTAL CATCH-ALL BY laARAT-ON MATERIALS, INC. Ill ­sM Construction a mod. standard seengih from, w/wire seem, I 1. Construct the sediment border of standard ahem' ar arm 3' mwx. erica shei ka6ric wlo we, (once strength synthetic filter fabrics. Steel I 2. Ensure that the height of the sediment fence ace, rot exceed 24 Post Z Plastic or inches the groundsurface. fogicund failurher e of the V volumesofwaterserfabricftocausefailureofther cure voluabovemes se eta SwreTre 3. of the filter taints from continuous roll c o the eolith F Fence - Me ba n securely Me tamer eyecloth 4'say fasten the filter cloth only at a support port with 4 ^e mih^:,;m fa r only t a support bore with overlap to the next post. 4. Supped standard filter wire toes lee ricpas the whirfost pe aid a s. mess securely to the side of the posts. n the n support to the ram of me bench Fasten the Mr bottom eep IIIleaa .��Noturol p and then fabricon theinimum sideof thefencepost wreorpasiic zip the NGround ties should have tensileis minimum 50 Foundfence space mesh used 5. When a wire mesh support fence is used, space Cods a FMer Fabric maxmum of 8 feet apart. Support posh should be mien securely 1 into the ground a minimum of 24 inches. 6. Extra strength filter fabric With 6 feel post spacing does rc- 8" downs require mesh support fence. Securely fasten me fltr'ubdc dlrecfly L� s forward Drone n fa post. wire or plastic rip ties should have minimu^' .�: pal. d Wire the trench rea le strength. Fence 7. Excavate a trench approximately 4 inches wide c-al 8 inches Steel Z ffter deep along the proposed line of posts and upaip om the Posh 'i a 8ackfiliMicronmpal and bonier. compact B. Place 12 inches of the fabric along the bottom a^=side o"^e AM thoroughly Natural trench. Moral (-Grouts 9. Back 1 the frenchMTh soil placed aver the filier'abic arc Ground -� \\1\ compact. Thorough compaction of the backfill is crcal to sl' fence performance. 10. Do not attach Biter fabric to existing trees. C Up4oPe MAINTENANCE 'E 1. Inspect sediment fences at least once a week sec niter each V rainfall. Make any required repairs immediately. N EO 2. Should the fabric of o sediment fence collapse. sue, decompose or become ineffective, replace it promptly. _ 3. Remove sediment deposits as necessary to provide adequate storage volume for the red rain and to reduce presses on ire fence. Take care to avoid undermining the fence dc-ng cleanout 4. Remove all fencing material and unstable sedmew deposits ontl bang the area to grade and stabilzie it after the contributing Sediment Fence drainage area has been properly stabiluad. Reference: NC treason and Sao monorail cars Plalms, and Devon Noma, PmcGre 6b2 % J PERMANENT SEEDING SPECIFICATIONS PURPOSE To equal eroabn and decreeas sediment yield from disllfad areas, and to intentional stabilize such areas in a mannerthat is emnomial, adapts to she mndNons, and allows aeleMon of the meet ,eppropre s plant materiels. Areas to be stabilized with permanent vegetation must be seeded or phial wiMl 15 working data or 90 ®larder days afterfinal grade is reached, whiMever period is shorter. PLANT SELECTION See table et right Use wrtified sesd for pemMrrent seeding whenever possible. Carl seed is imposed #a North Carolina Crop Improvement Association. co M P P Labeling coon-mrtified seed is required bylaw. SEEDBED PREPARATION install necessary mechanical erodon mnVvl practicoe before seeding, ant compete radio according to the approved Ian. grading g PP P Lime and ferfiliearneeds should be determined by mil testa. When soliteals am not available tolkev rates suggested on table at night ApplicarJon .We ususelly fall into Me Totaling ra sin s' -Ground Agricultural limestone Li ht-teraoed m sails I-1 lnslaare 9 My Y Heary-Iaxhrtetl, clayey adls:2-3 tonNeaa FeMIUar Gresamgura n2001b/eaa o110 lwor (or egdvNeM) Gresakgume mbaura: BIgi200lMacre 51410. lime and fern er areal and monsignori into m a 46 inches of and b APPY Yemat P Y rakn hydrometer, lime means Operate mugh on the oxtour. Man udn a 9 P very g h draeeder apply Ilma and feNlizmtoarou h lsurface. Y PPY 9 Does complete seedbed profession by breaking up lane Gods and mini g Into a smooth, uniform surface (sbpes less than 3:1). Fill in or level connotations, Mat can called water. Broadcast marl Into a Brand, bosened seedbed that has not been sealed by Alnfall. MULCHING The use of an appopriate mot& will help ensure establishment under normal conditions and se eassamal l seeding success under harsh site conditions. Harsh site conditions induce: ,slopes steeper Man 3:1 -screaming, Mt or dry weather -adverse sills (shallow, root, of high in day or .no) areas becoming concentrated waterflow Ifthe arse to be mulched is..Mad to concentrated water flow as in chsandmi anchor mulchwiMnetrng. IRRIGATION Moiature is ass i for good seed gemnireean and equaling establishment. Supplemental irrigation can be very helpful In assuring adaquare stands in dry seasora onto speed development of NII coven Water appkcul will ..at be carellly comershad to prevent rui lnadaqual or exmulve...net.,(water Con Be more harmful Man ro supplemental welt. MAINTENANCE Generally 9 stand ofvegetaflon cmnM be tlelrtninetl to befully astonished until soil cover has been maiM ired or we full year ant tarefog . Inspect seeded areas for P failure and make necessary rapelre and reveatlings within Me same season. H possible. Resmding-If a stand has inadequate cover, re-araluate choice a plant materials anal quantires of lime and ferMizer. Reestablish MeMod after seedbed preparation or own,xiitl me stard. consider seeding temporary, annual spades if the time of year is not appropriate for permanent seeding. If Me vegetation hail as grow, have mil tested to determine t acidity or nutrient Imbalance is responsible. Fe llffoetioni Me lypical disturbed ace full establishment usually requires relrtigzador in me second growing seams Fine ld requires annual maintenance ferlil'¢ation. Um ma test a porsible orfollaw Me guidelines given forme apadfic seeding mixture. REFERENCE - NC Erzaloa and Sediment Control Planning and Design Manual - Prad it 6.11 CoarM, Compacted w-w. i _ 6-ft typical it FOR WELL -DRAINED SANDY LOAMS TO DRY SAHOS: LOW MAINTENANCE MIXTURE: Pensamia Bebiagmsm - So Inte la Senicee bspefam-301Wacre Cam. Bennudsgress-10lblaae Games millet-10 Blade SEEDING NOTES: 1. Where a neat eppearanre is desired, snit sencea. 2, use common Bermutlegmss only on isolated saes where A cannot became a pest. Be reada,mse may he replaced win 5 Ibt..nnpedegrms. SEEDING DATES; Abel -July 15 SOILAMENDMENTS Apply litre and fertaizer amoding to ail tests, or apply 3IM Indiana ground agrachurel limestone and 500 license 10.1040 fettles. MULCH Apply 40001Wacre grain saaw or equivalent cover of aamer suitare mulch. Anchor by IecM With as list mute or noting or Y P L bl 9 re camping ht in mulch d as a m loot. A diskw t blades set ninny simlgM can be used as a mulch anchoring fool. MAINTENANCE ReferHlixe Me following April with 501Macrs nitrogen. Reped as gnov4n requires- Maybe mowed om/an®a year. Wtere a neat aPa membe is deared omit serima and mow lie often as needed. OeNQManual, Table 6 I9REFE NC and sediment control Planningand WELL to POORLY DRAINED SOILS wfth WOO MOISTURE RETENTION: LOW MAINTENANCE MURURE: Tall clinical -80 Moore Persuade Bahia,.. - 501re.. annoys aspedeza - 30 Rye.. Kone leafed.-10 blade SEEDING NOTES: 1. From Sept 1 - Mar. 1, use uaatlrletl scree seed. 2. On poody drained slim omit sences and inarease Kobe to 30 Hobbs, 3. Ms. is ,.at appeerena a desired, and sense and increase KobetoQ locacre. NURSE PLANTS Between Apr. I and Aug 15, add 10IWacre German millet or 15 Readies Bud.,. Pda to May 1 or titer Aug. 15, add 251Waae be, (grad). SEEDING DATES; Early sprig - Feb. 15-Mar. 20 (bust) Feb. 15-Apr. 30 (possible) Fall - .1- t. 30bast Seat, 21 (possible) 9ap1 Sep (bass) co (P 7 SOILAMENDMENTS Apply It. end forge er acmMing M and test, alai 3000.5000 Inside ground agricultural limestone use Me laver men an sand rolls) and tpp0lWacre 10.10.10radical MULCH Apply 4WD lawcre grain some or equivsleM cover demand, suitable mulch. Anchor by tacMng with sooner, roving or rating or by crimpling won a mulch anchoring tor. A disk with blades act reedy straight can he used as a mulch anchoring fool. MAINTENANCE If grower le ima man Nlly adequal, mfeMi' In the mmnd year, as-aonn, W son test or topdmm with 500IWaue t0-10-10 ferlll um Maw as nettled when metal is omitted from the mNtum. Reseed, faaiibe and mulch damaged areas immediately, REFERENCE- NC Erasfon and Sediment Carl Planning and Design Manual, Teble 6.iip TEMPORARY DIVERSION (FOR VEHICULAR CROSSING) TEMPORARY DIVERISIOIN BERM (NOT TO SCALE) and Sediment Contra Planning and Design Manual - Practice,6.20 rilterclom CHECK DAM DETAIL SHOWN ON THE INLET SIDE OF STONE OUTLET ­`F of NcoornB or tier nheanrend Ira tees a moan --4 A CHECK DAM WEIR LENGTH = 3D FT. MINIMUM STEEL NICDOT #5 OR #57 WASHED STTO'�NE `r, " NO STONE OU FLET DETAIL, W)TTOSCAI£ T10of T. he W- n din t- fee ances, a,,.. Provide oakciblone to yearmma I borate as m unt Sec I. a.,,peon set N- iWegtma,,.c - tbv i. fdr khe rNn In ed.,.mPe men T M1 ,Iu .n 4r 9 fly A - nb,r .dnw.k-rr O 1 d 1 b .try C0rhpkTImT10N_ 9Y�ilJuAUbRS Srmn softoo 2 mi We Ne pnuta smarnmed, aseme de. carelng. dedurgad. by poor f4f nowt. SmmradlnesJU g bekycd a e. a aadtM1 pit. m gerlmhardoo,com, Saw M oistome,nei,sauaths dap.andeddla,dedtonord It 3 exxondrulad to slice I 2-rom BP adds, lie mesh charges g "Imiremoonng. ] Place loan wacal Wool #5 nr W didea) an e 2 l slope with a height of 16 inches uowd she eqm, and fori,,, an fees an 4. haw se aonMMtMg demand slim has been small tamale the naae oalelend etl c'eremadandanfinner, Bmg,"a.fledgaresselooring 5. Compact lie area rmpely and rtabhiaa It well, gmundrover. MAINTENANCb I. looped aleartweekly and aft-M1 sippltleml(1/2inch ordeseo minrellevwr Mat ,dy Icou'e iwnedlurell. CmA deveva nd fed, erosion. piping and mek 4upleoemem- famous g- asnacdd N d lei uY p I. tan• t'man, t nor h a' h 'I r td'b el Lt I' I'd rl r -e lust'en, "kesae de Jsmaar JrmMm"neEe e: eea,tg seFat mrd STONE OULET TOPSOIUNG Constructlon Specifications Materials 1. Determine whether the quality and quantity of available topsoil justifies selective handling. Quality topsoil has the folikve ng characteristics: a. Text re -loom sand loam n it loam re best sand clay loom si clay loam clay loam and u Y ,a and a Y Y rY muck Y sand are fair. r not use heavy clay and organic soils such as peat or muck for topsoil. b. Organic mattercontent-should greater team well c. Acidity- should be greaser thann lim 3.6 before ing,or ght. ann d liming is requit r iatl u less than 6.0. . Soluble wits - should be less than 500 ppm. e. Sodium of sodium should absorption ration shoudl be less than 12. to The depth of d over t should beat least 2 inches. Soil factors such as Cock g of topic, slope, depth to water Coble, and Byerthickness affect the ease ofexcavation and spreadingoftopsoil. 3. Generally, the upper part of the ve which h richest in organic matter, b most deskaWe: however, material excavated from deeper layers may be wanes stoning t if a mesh the other cnteea hated above. 4. Organic soils such t mucks and pears do not make good topsoil. They can be identified by their extremelylight weight whentl . 9 9 ry. Stripping 1. Strip topsoil only from those areas that will be disturbed by excavation, filling, road building, Or compaction by equipment. A 4-6 inch stepping depth is common, but depth varies depending on the site. Determined depth of stripping b taking it cows f several locations within each area to be shipped. tip pp e y n g sr c re a pp Topsoil depth generally varies along a gradient from hilltop to toe of the slope. Put sediment basins, diversions and other controls into place before sopping. Stockpiling 1. Select stockpile location to avoid slopes, natural drainage ways and frame routes. Onlcrge sites, . respreading is easier and mare economical When topsoil is stockpiled in small piles located near areas where they will be used. 2. Use meat fencesstockpiles beam nor ly s re ring sss n s pas bl,nosediment ry 3. Protecttopsoil stockpilesbykpile. anN seeding as soon as possible, no more than 21 calendar days 4. If s me formation of the stockpile. 4. If stockpiles will not be used within 90 days they must be itablizetl lath permanent vegetation to control erosion and weed growth. Site Preparation 1. Before spreading topsoil, establish erosion and sedimentation control practices such as diversions, berms, dikes, waterways and sediment oasins. 2. Maintain grades on the areas to be topsoded according to the approved plan and do not alter them by adding topsoil. 3. Where the pH of the existing subsoil is 6.0 or less, or the soil is composed of heavy clays, recorpomte agricultural limestone In amounts recommended by soil test or specified for the seeding mixture to be used. Incorporate lime to a depth of at least 2 inches by disking. 4. Immediately prior to spreading the topsoil, loosen the so bgrade by disking or marrying to a depth of at least 4 inches, to ensure bonding of the topsoil and subsoil. If no amendments have been incorporated. loosen the soil to a depth of at least inches before spreading the topsoil, p 6 e p g h Ps Spreading Topsail 1. Uniformly disMbute to soil to a minimum compacted depth of 2 inches on 3:1 slopes Ord 4 inches on P P P P Fallen slows. To determine the volume of topsoil required For n the ughu evarious depths, use Table 6regul Do not spread topsoil while it's frozenm muddy a when the ions to prevent lei or frozen. Correct any depressions ns in the er pockets, that result from topsoiling or other operations to prevent the formation of depressions or water pockets. 2. Compact the topsoil enough to ensure goon contact woo the underlying soil, but avoid excessive Co compaction, as t Increases n off and inhibits seed germination. Lightght deciding woe a toter 6 recommended Where highmainot e m turf is to be established. 3. On a and areas that will not be mowed the surface tie th let tau h after spreading topsoil. A slopesY 9 P 9 P disk maybe used to promote bonding at the interface between the topsoil and subsoil. 4. After topsoil application, follow procedures for seedbed preparation, taking care to ovoid excessive pricing of topsoil into the subsoil. TABLE 6.04 a Cubic Yards of Topsoil Required for Application to Various Depths DEPTH (inches) Per 1000 sq. ft. Per Acre 1 3.1 134 2 6.2 268 3 9.3 403 4 12.4 536 5 15.5 670 6 18.6 804 Reference: NC Erosion and Sedimentation Control Planning and Design Manual, Practice 6.N ba- PURPOSE To protect work areas from upslope runoff and to divert sediment -laden waterto appropriate traps or stable outlets. DESIGN CRITERIA Drainage area - 5 acres or less. Capacity - ale mnoff from 10- n. storm P y Pe Y Ridge Design - Side slope. 2:1 or Bader 3:1 or Flatter where vehicles cross Top Width2 ft. minimum practical: 0.3 A. minimum Settlement'. 10%cf total fill height minimum Channel Design - shape: parabolic, trapezoidal or V-shaped aide slope: 2:1 or flatter 3:1 or flatter where vehicles cross Grades - Ether a uniform or a Brea ialb, increasing grade is preferred. Sudden decreases In grade accumulate sediment and should be expanded he cause overtopping. A large increase in grade may erode. Temporary diversions designed to function 1 year or more, or they may be Constructed anew at the end M each day's grading operation to probed new fill. Diversions that are to score longer man 30 working days 9i could be seeded and mulched as soon as they are constructed to preserve dike height and reduce maintenance. Wherever feasible, build and stabilize diversions and outlets before initiating other land-disWming activities. CONSTRUCTION SPECIFICATIONS 1. Remove and County dispose of ell trees, brush, stumps and Omer objectionable material. 2. Ensure that the minimum constructed cross section meets all design requirements. 3. Ensure that the top of the dike is not lower at any point than the design elevation plus the specified settlement. 4. Provide suffidant boom around diversions W perms machine regrading and cleanout. 5. Vegetate Me ridge immediately after construction, unles it will remain in place less than 30 working days. MAINTENANCE Inspect temporary dissenters at least once a week and after every rainfall. Immediately remove sediment imm the flow area and repair the diversion ridge. Carefully check outlets and make timely repairs as needed. When me area protected is permanently stabilized remove the ridge and the channel to blend with ft natural gmund level and appropriately 1 staWIRB 11. / Zil u DETAIL OF STONE PROTECTION OUTLET f3 WITH CHECK DAM Know what's below. Cell before you dig, Table 6.14a Mulching Materials and Application Rates MATERIAL RATE PER ACRE QUALMY NOTES Organic Mulches Show 1-2 tons Dry, unchoppetl Should come ham wheat or Dots unweathered, avoid spread by hand or machine: must weeds tacked down -- Wood chips P '- 5-6 tons _- _ --be Kr dry Treat with 12 Ibs nitroen/ton. Apply with mulch blower, chip handler, or by hand. Not for use in fine Wood fiber _-- 0.50-1 tons _ -- -surf. -_ Also referred to as wood cellulose. Maybe hydroseeded. Do not use in hot dry weatheach er. Bark 35 cubic yards Air dry, shredded or Apply with mulch blower, chip handler hammer -milled, or or by hand. Do not use asphoft tack. chips _____-___-_--_ Cam stalks 46 tons __ u or shredded in 46 Cut A with mulch blower or hand. PPN Y Inch lengths Not for use In fine turf. -_- Sericea --- 1-3 tons ___ Green or dry; should -- Iespedeza contain mature seed seed -bearing stems b ----_--.- and Make __.--_--_----_--_- Jule Net Cover Area Heavy, uniform; woven Withstands waterflow. Beef When used of single jute yom with organic mulch. Fiberglass net Cover Areo J Withstands waterflow. Best When used organic mulch Excelsior Mot ' Cover Area -- -_-wilts - Withstands waterflow. (Wood Fiber) Rberglass roving 0S0-1 tons Continuous fibers of Apply with a compfessed air ejector. drawn glass bound Tack with emulsified asphalt at a rate together with a non- of 2S-35 gal/1000 sf toxic agent Chemical Stob]Km Aquotain Follow manufacturers Not beneficial to plant growth Aerespray Instmctions Coal AK Pertoset SB Terra Tack Crust 500 Genial 743 M-145 REFERENCE: North Carolina Erosion and Sediment Control Planning and Design Manual, Practice 6.14 . m DO NOT USE FOR CONSTRUCTION SURFACE ROUGHENING Construction Scecificotlns CUT SLOPE ROUGHENING FOR AREAS NOT TO BE MOWED I. Stair -step grade or groove cut Slopes with a gradient steeper than 3:1 2. Use stair -step grading on any erodible material soft enough to be doped with a bulldozer. Slopes consisting of sot rock with some subsoil are particularly suited to stair -step grading. 3. Make the vertical cut distance lass than the horizontal distance, and slightly slope the horizontal position of the lgep' in toward the vertical wall. 4. Do not make individual vertical cuts more than 2 feet in sell materials or more than 3 feet in rocky materials. 5. Groove usinga appropriate im ment that can be safe operated on the slope, such as disks fillers spring handle or anyndimplement ly P P P 9 the teeth on a hoot -end loader bucket. Do not make such grooves less than 3 inches deep nor more than 15 inches apart. FILL SLOPE ROUGHENING FOR AREAS NOT TO BE MOWED 1. Place fill slopes With a gradient steeper than 3:1 in M no to exceed 9 inches, and make sure each lift is properly compacted. Ensure that the face of the slope consists of loose, uncompacted fill to 6 inches deep. Use grooving to roughen the face of the sopes. 2. Do net blade or scroa the Mal slope face. P P CUTS, FILLS AND GRADED AREAS THAT WILL BE MOWED 1. Make mowed slopes no steeper than 3:1. 2. Roughen these areas to shallow grodvos by normoi tilling, diskng, harrowing or use of cultipacker-sdeeder. Mate the firm pass of arty such fillage implement n the contour. 3. Make grooves, formed by such Implements, close together (less than 10 inches) and not less than 1 inch deep. 4. Excessive roughne, is undesirable Where mowing is planned. ROUGHENING WITH TRACKED MACHINERY 1. Until mu henin with tracked machinery to sand soils to avoid undue compaction of the soil surface. Tracking is 9 9 cry P 9 generally not as effective as the other heal methods during the Operate op machine u and down the slope 9e Y toughening P machinery P Pe to leave honzonfol depressions in Me soil. Do not back blade during the final grading operator. SEEDING Immediately seed and mulch roughened areas to obtain seed gemination and growth. Maintenance Periodically check the seeded slopes for ells and washes. fill these areas slightly above the original grade, then reseed and mulch as soon as possible REFERENCE: Norm Carolina Erosion and Sediment Control Planning and Design Manual, Practice 6.03 J SKIMMER SEDIMENT BASIN (Practice 6.64) CONSTRUCTION SPECIFICATION 1. Clear, grub, and strip the area under the embankment of all vegetation and root mat. Remove all surface soil containing high amounts of organic matter and stockpile or dispose of it properly. Haul all objectionable material to the designated disposal area. Place temporary sediment control measures below basin as needed. 2, Ensure that fill material for the embankment is free of roots, woody vegetation, organic matter, and other objectionable material. Place the fill in lifts not to exceed 6 inches to allow for settlement. 3, Shape the basin to the specified dimensions. Prevent the skimming device from settling into the mud by excavating a shallow pit under the skimmer or providing a low support under the skimmer of stone or timber. 4, Place the barrel (typically 4-inch Shedule 40 PVC pipe)on a firm, smooth foundation of impervious soil. Do not use pervious material such as sand, gravel, or crushed stone as backfill around the pipe. Place the fill material around the pipe spillway in 4-inch layers and compact it under and around the pipe to at least the some density as the adjacent embankment. Care must be taken not to raise the pipe from the firm contact with its foundation when compacting under the pipe haunches. Place a minimum depth of 2 feet of compacted backfill over the pipe spillway before crossing it withconstruction equipment. In no case should the pipe conduit be installed by cutting a trench through the dam after the embankment is complete. 5, Assemble the skimmer following the manuffacturers instructions, or as designed. 6, lay the assembled skimmer on the bottom of the basin with the flexible joint at the inlet of the barrel pipe. Attache the flexible joint to the barrel pipe and position the skimmer over the excavated pipe or support. Be sure to attach a rope to the skimmer and anchor it to the side of the basin. This will be used to pull the skimmer to the side for maintenance. 7, Earthen spillways - Install the spillway in undisturbed soil to the greatest extent possible. The achievement of planned elevations, grade, design width, and entrance and exit channel slopes are critical to the successful operation of the spillway. The spillway should be lined with laminated plastic or impermeable geotexiile fabric. The fabric must be Wide and long enough to cover the bottow and sides and extend onto the top of the dam for anchoring in a trench. the edges may be secured with 8_inch staples or pins. The n enough i extend down the to an xit onto stable ground. The width of the fabric must be one piece, not joined or liked' otherwise water ccan et fabric must be o e ou D e e s d e d e 9 9 Pe 9 P 1 P 9 under the fabric. If the length of the fabric is insufficient for the entire length of the spillway, multiple sections spanning the complete width may be used. The upper section s 9 9 P Y P P 9 P Y PP () should overlap the lower section(s) so that wafer cannot flow under the fabric. Secure the upper edge and sides of the fabric in a trench With staples or pins. 8, Fillets - Discharge water into the basin in a manner to prevent erosion. Use temporary slope drains or diversions with outlet protection to divert sediment -laden water to the Upper end of the pool are to improve basin trap efficiency. 9, Erosion Control - Construct the structure so that the disturbed are is minimized. Divert surface water away from bare areas. Complete the embankment before the area is cleared. Stabilize the emergency spillway embankment and all other disturbed areas above the crest of the principal spillway immediately after construction. 10. Install porous baffles as specified in Practice 6.65, Porous Baffles. 11. After all the sediment -producing areas have been permanently stabilized, remove the sfructre and all the unstable sediment. Smooth the area to blend with the adjoining areas and stabilize property. MAINENTANCE Inspect skimmer sediment basins at least weekly and after each significant (one-half inch or greater) rainfall event and repair immediately. Remove sediment and restore the basin to its original dimensions when sediment accumulates to one-half the height of the first baffle. Pull the skimmer to one side so that the sediment underneath it can be excavated. Excavate the sediment from the entire basin, not just around the skimmer or the first cell. make sure vegetation growing in the bottom of the bottom does not hold down the skimmer. Repair the baffles if they are damaged. Re -anchor the baffles if water is flowing underneath or around them. If the skimmer is clogged With trash and there is water in the basin, usually jerking the rope will make the skimmer bob up and down and dislodge the debris and restore flow. If this does not work. pull the skimmer over to the side of the basin and remove the debris. Also check the orifice inside the skimmer to see if it is clogged; if so remove the debris. If the skimmer are or banded pipe is clogged, the orifice can be removed and the obstruction cleared with a plumber's snake or by flushing with water. Be sure and replace the orifice before repositioning the skimmer. Check the fabric lined spillway for damage and make any required repairs with fabric that spans the full width of the spillway. Check the embankment, spillways, and outlet for erosion damage, and inspect the embankment for piping the settlement. make all necessary repairs immediately. Remove all Mash and other debris from the skimmer and pool areas. Freezing weather can result in ice forming in the basin. some special precautions should be taken in thewinter to prevent the skimmer from plugging with ice. feepasseencessassess Mf, 4v/\!/\v/` T j\j\/\/\I\/I "'W \/\/\i :e e e �� a �Oj\\jQ/\ Section Ada OUTLET TO FLAT AREA WITH NO WELL DEFINED CHANNEL NOTE: In both figures, the thickness of dpmp is a shown in plans (minimum thickness is 1.5 limes the maximum stone diameter. CONSTRUCTION 1. Excavate subgrade below design elevation to allow AN, thidoless of filler and fixal Install Opal tP minimum thickness of 1.5 am" maximum stone diameter. Final structure should be to lines and elevations shown in plan. 2. Construct apron on zere grade. If there is no weH defined channel, cress section may be level or slightly depressed in the middle. In a Well defined diamonds extend dpmp and filter fabric to the top of the bank or as shown on plans. Blend dpi smoothly W ant surrounding land. 3. Apron should be straight and properly aligned with the anceiving stream. If a curve is necessary to fit site donations, curve the apron near the upstream and. 4. Compact any fill used in the su ograde to me density of surrounding unaisuubed material. Subgmde should be smooth enough to Protect fabric from tearing. S. Indeed a Continuous section of extra strength fitter fabric on smooth, Compacted foundation. 6. Protect than fabric Tram tearing while placing dpmp wM machinery. Repair any damage immediately by removing siprap and installing another section of fitter fabric. Upstream motion of fabric should overlap downstream section by a minimum of i 1 mariermalapalpapapim'sove. Riprep should THI DRAWING IS NOT A CERTIFIED SURVEY AND NO RELIANCE MAY BE PLACED IN ITS ACCURACY. THI DRAWING HAS NOT BEEN REVIEWED BY ANY GOIN ERNMENTAL AGENCY FOR COMPLID19LATI.5 ANN APPLICABLE LAND DEVELOPMENT OR OTHER RE( ULATIONS. EXISTING INFORMATION IS BASED IIIONItI;F4AEBiEF4LAND6D0WNWl®tA&nD1 W^MsignManual, Section A -A OUTLET TO WELL DEFINED CHANNEL Filter Blanket MAINTENANCE 1. Inspect riprap outlet structures after heavy reins for erosin at sides and ends of apron and for alone displacement. 2. Make repairs immediately using appropriate stone sizes. Do no place stones above finished grade. 3. Repair any damage to filter fabric by remaining the dpmp and placing another piece of fitter fabric over the damaged area. All Connecting joints should cynal by at least one foot ff the damage to the fabric is extensive reply a entire filter cloth. LZATION STRUCTURE )tto scale) F Q I Ili. 2 E . ... a LCall n - O Ln 0 Ine) 0 04 CO ? C Tq O N (`7 a _ 4 ) � -r- l DO Z) 0 cD a •_ 0 0 I Do C V O 70 C ODo a` iN�U�.or _ W E L O IN j Ic °� � O pass,C0 0 0 U 00 Z MC i Di �' C sT ,b� 1 M4 y Cie)N M U (7 Z-Q..Y. to - CC):J O X O N'hes " E� W O<<}0 z ` aO M Oi ; wJM1.�--� MTUZ - OdZa `t\\\\fill If�3t/�'S si i 'i 9%9 = = EAL = = pAo�ww 114p 5 tocr AxxL/? 17 `` 4/ ��� v NG ��%.,� f IT I/lllllllit111\\\'IN THIS DRAWING IS PRELIMINARY, AND NOT FOR CONSTRUCTION, RECORDING PURPOSES OR IMPLEMENTATION. C O N .5 m Of m a O O Z Owner: CBMMPROPERTIES LL C CONTACT.. 238 N. MCPHERSON CHURCHRD FAYE=117LLE, NC 28303 PHONE:910-864-1125 FAX.'910-864-0938 Project: THE ESTATES OF GEORGETOWN PHASE I g 0405-42-0744 tax id 0405-52-1954 A: 0405-51-2958 township: Rockfish County: Curglouland state: NC EROSION CONTROL DETAILS CONSTRUCTION DOCUMENTS job I P12-096 date: 12�02� 13 drawn by: PDM Burley by: JTR checked by: JAN sheet no.: C22 z z y (V 0 ON 00 ul N N OM z 00 W'U 0 y — °0 0 oo 00 z y t LL O E >a p O O N U N Up 00 M� 2 C m coN-0 lf) .> 00 J O ]C x CCp CY O L J W � `a coL} a=� w�- qM Oa_z Bch Eli n ...�amuunwirV,yi Willi H9< 9''' SEAL c 031so '�%. Tey THIS DRAWING IS PRELIMINARY, AND NOT FOR CONSTRUCTION, RECORDING PURPOSES OR IMPLEMENTATION. c 0 M Q d v 0 0 0 z Owner: CBMMPROPERTIES LLC CONTACT.- 238 N. McPHERSON CHURCHRD FAMTEWLLE, NC28303 PHONE:910-864-1125 FAX 910-864-0938 t Project: THE ESTATES OF GEORGETOWN PHASE 1 0405-42-0744 tax id o044os-51-29ss township: Rockfish county: Cumberland state: NC DRIVEWAY PERMIT DRAWING CONSTRUCTION DOCUMENTS job no.: P12-096 date: 12/02/ 13 drawn by: PDM survey by: JTR checked by: JAN sheet no.: C23