Loading...
HomeMy WebLinkAboutSW3220301_Plansheet 2 - Proposed Conditions_Site Plan_20220420DECORATIVE BRICK COLUMN ENTRANCE 74 (DESIGN BY OTHERS) HW TO BE LOCATED OUTSIDE OF SIGHT TRIANGLES 100 PUBLIC R\\N (PC. M, FILE 699) STATE PROJ. # B.1691BO2 ohe LIGHT ohe ------ POLE ohe \ohe R'W 0 - ----- O� 01 0 R\ WATE\N R-:.��ME7 0 8' STREETSCAPE BUFFER POWER POLE PROPOSED 6' TALL CHAIN LINH FEWCIV* "I RAISED ISLAND FOR ENT/EXIT KEYPADcan I POWE POLE PIN: 09054040A CHILDREN OF TODAY CHILD NEVEMI LOPMENT CENTER, INC. DB. 6747, PG. 31 PC. M, FILE 699 PIN: 09054038A JAMES LEO GOSS, IF DB. 3523, PG. 64 I PROP. 20-113" STANDARD CURI P_ GUXC7,,12 ohe Lfun I t\ POLE 1\ MO A mom STREET TREE ohe ohe --------- R\W SIDEWALK TO TIE EXISTING VARIES 6'-0" 81-01, 5._011 ---------------- 1/4"/FT 1/4"/FT V'/FT _21147FT ----------- NCDOT REQUIRED DRIVEWAY PROFIPUTS LE z I,-,' PROPOSED ASPHALT PAVING ---- ------- 1_� Ln 76P LIGHT PROPOSED GRAVEL PAVING II �a III .�C���I. .IjI I. iI: �` I Ia II ------ ohe CURB N he R\\N 8' STREETSCAPE lot— BUFFER skm TREE TO SERVE AS STREET a) 0 06 TREE/PARKING SHADE X PIN: 09054017H _CN VAN —ACCESSIBLE O'RILLY AUTOMOTIVE STORES, `INC. n PACEj DB. 7303, PG. 474 TIRE STOP PC. P, FILE 326 0- Q: (TYPICAL) ro PROPOSED 5' WALKWAY TO SERVE AS REQUIRED ADA ACCESSIBLE ROUTE TO -0 (0 SIDEWALK WITHIN PUBLIC R/W PROPOSED 6' TALL (REF MIN. ADA CONSTRUCTION IM CHAIN LINK FENCING MENTS) REQUIRE _0 C=>1 WITH 4' GATE FOR ADAI ACCESSIBLE ROUTE TO CJ4 =r 0 a) a OFFICE UNIT X a) M ED Ln PROPOSED 6 w-TA LL CHAIN L C) X 4h. (A CA LINK FENCING X X CA X ER 0 -�I,"AWNH LE 163 sf. (Deed Overlap) as— I 0 I N83'3655"E 106.22' --- % EX LIGHT o e 7§� 24 POLE EARTH 24" 70 165-63 CC" SITE PHASING 1. Proposed site to be phased based on capacity. 20x5O IQ> ki W 2. Full site clearing & grading to be performed PIN: 09054034A CIO during Phase 1 construction. JUNE MINCEY IV DB. 4513, PG. 774 P MP 3. Erosion control skimmer basin to remain in place until completion of Phase 3 construction which 2 CIO I at such time shall be converted to the required stormwater control measure (SCM). 7 4. Gravel placed in future building pad locations to serve as temporary storage and parking. ANTICIPATED BUILDING PHASING CIO EHAS-E-1 -77777777777 CO PIN: 09054035 CURB BUILDING #1 (2600 sf) FRANCES B. KNIGHT DB. 3594, PG. 838 BUILDING #2 (3100 sf) A BUILDING #3 450 sf) BUILDING #4 (6300 sf) '30 PHASE 2 BUILDING #5 (6000 sf) 0 Olt BUILDING #6 900 sf) PH AS SEWER BUILDING #7 (1500 sf) I ' % % ®�� MANHOLE BUILDING #8 (1000 sf) 1 PROPOSED PIN: 09054040 _j �a 20' SD SAND FILTER MINI STORAGE USA, INC, iz� (STORM DRAINAGE SCM DB. 8240, PG. 298 PC. M, FILE 699 CI-) EASEMENT) CENTERED UN EXISTING DITCH LI 11 PIN: 09054036 JACOB CLONTZ & ss z KAYLEIGH BIVENS DB. 7701, PG. 23 zz DOUBLE GATE FOR SCM ACCESS SEWER MANHOLE PIN: 09054037 NORMA MATTHEWS WORD DB. 6143, PG. 31 NOTE: PROPERTY BOUNDARY AND FIELD TOPO DATA PROVIDED BY LAWRENCE ASSOCIATES, 106 W. JEFFERSON ST., MONROE, NC 28112, 704-289-1013, www.lawrencesurveying.com OWNER / DEVELOPER INFORMATION ini Storage USA, Inc. 4724 Old Monroe—Marshville Road Marshville, NC 28103 Contact: Danny Jordan 704-361-3619, Danny.DTPH@gmaii.com I . ALL TREES SHALL HAVE A MINIMUM CALIPER OF 3 INCHES, 1 MEASURED 6 INCHES ABOVE GROUND. 2. TREES SHALL BE A MINIMUM OF 8 FT TALL AT TIME OF PLANTING. 3. TREES SHALL BE PLANTED IN ACCORDANCE NTH THE TOWN OF WINGATE LAND USE ORDINANCE. PM- SITE INFORMATION: PROPERTY IDENTIFICATION NUMBER: 09-054-04C DEED REF: 8240-298 PROPERTY OWNER: MINI STORAGE USA PROPERTY ADDRESS: 3622 W HWY 74 WINGATE, NC 28174 EXISTING SITE USE: VACANT (PREVIOUS RESIDENTIAL) EXISTING ZONING: B-1 TOTAL SITE AREA: 1.95ac (Outside NCDOT R/W) EXISTING IMPERVIOUS: 3,520sf (0.081ac)* = 4.154% *Exlsting Impervious estimoted from historicol oerldl data PROPOSED PROJECT PROPOSED SCOPE: SELF STORAGE UNITS (Class 2) PROPOSED LAND DISTURBANCE: 1.8ac PROPOSED IMPERVIOUS: (Outside NCDOT R/W) A BUILDING #1 (2600 sf) BUILDING #2 (3100 sf) BUILDING #3 ( 450 sf) BUILDING #4 (6300 sf) BUILDING #5 (6000 sf) BUILDING #6 ( 900 sf) BUILDING #7 (1500 sf) BUILDING #8 (1000 sf) TOTAL STORAGE AREA: 21,850 sf PROPOSED SET���SB�l STREET 10 FEET SIDE 0 FEET REAR 0 FEET PROPOSED PARKING STANDARD 9'x20' PARKING SPACES: 2 (Gravel) H/C VAN ACCESSIBLE SPACES: 1 (Concrete) TOTAL SPACES PROVIDED: 3 (Approx. 1 Space/7400sf Storage) STREETSCAPE SCREENING REQUIREMENTS: A STREETSCAPE BUFFER SHALL BE PROVIDED IN ACCORDANCE WITH SECTION ® OF THE TOWN OF WINGATE'S LAND USE ORDINANCE. OUTDOOR LIGHTING LIGHTING SHALL NOT BE DIRECTED TOWARD OR SHINE UPON ANY RESIDENTIAL AREAS OR ENDANGER MOTORISTS TRAVELING ON ANY STREET. EXTERIOR LIGHTING SHALL COMPLY WITH CITY OF MONROE UDO. WATER & SEWER SERVICE #ROPOSED DEVELOPMENT TO BE MINI —WAREHOUSE UNITS ONLY AND SHALL NOT U11LIZE WATER & SEWER SE.,VICES. TIlRASH PICKUP: ROLL OUT CONTAINER TO BE USED FOR TRASH PICKUP. STORMWATER MANAGEMENT PROJECT IS SUBJECT TO PHASE 11 POST— CON STRU CTION STORMWATER REQUIREMENTS. SITE ACCESSIBILITY IT SHALL BE THE SITE CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT THE ACCESSIBLE PARKING SPACES AND ROUTES ARE CONSTRUCTED IN FULL COMPLIANCE WITH NC BUILDING CODE REQUIREMENTS. ANY FIELD CHANGES TO THE BUILDING OR SITE MAY REQUIRE MODIFICATION TO DESIGN PLANS IN ORDER TO MEET THIS REQUIREMENT. GRAPHIC SCALE 0 30' 60' IN FEET 1 inch = 30 f t. I I I r THIS DOCUMENT, PRESENTED AS AN INSTURMENT OF SERVICE, IS INTENDED ONLY FOR THE SPECIFIC PURPOSE AND DCLIENT FOR WHICH IT WAS PREPARE. IT SHALL NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, NOR USED ON ANY OTHER PRRMISSION.OJECT WITHOUT WRITTEN PE 16101 Silver Road Oakborp, NC28129 980-621-0935 vin Vi !DATE: 12/15/2021 HORIZ. SCALE VERT. SCALE NIA keh DRAWN BY.