Loading...
HomeMy WebLinkAboutNC0024147_Modifications IUP 000013_20220322 Trn Qitp of 'anforb WASTEWATER MANAGEMENT FACILITY Sarah Jordan Pretreatment Coordinator sarahJordan aasanfordnc.net Phone:919-777-1783 March 21,2022 Mr. Keyes McGee RECEIVED Department of Water Quality, PERCS GV 1617 Mail Service Center MAR 23 2022 Raleigh,NC 27699-1617 NCDEQ/DWR/NPDES Subject: Permit Modifications for IUP 000013, IUP 000033,and IUP 000041 Dear Mr. McGee: The City of Sanford is submitting modified IUPs 000013, 000033,and 000041. Modifications are as follows for each IUP. • IUP 13: The TTO Sampling requirement for the City was changed to"1 per 12 months providing the certification is not submitted"to align with other IUPs on the pretreatment program. • IUP 33: Changed the pipe 02 flow limit from 0.0373 MGD to 0.044 MGD due to an employee and production increase. Also removed the COD monitoring requirement on pipe 02 for the City of Sanford POTW. Clarified the City's TTO requirement on pipe 01 to align with the rest of IUPs on the pretreatment program. • IUP 41: I fixed typographical error in flow limits from 0.5 MGD daily max to 0.05 MGD monthly average and removed COD monitoring. Attached is a copy of each modified permit,copies of each of the transmittal letters, and an updated allocation table. If there are questions or comments please feel free to contact me at(919)777-1783. Sincerely, 4-t1/ Sarah Jordan Pretreatment Coordinator City of Sanford Enclosures �� P.0.Box 3729 PHONE(919)777-1783 Sanford,NC 27330 Fax (919)776-5037 4Lttp of 'anforb SARAH JORDAN Pretreatment Coordinator sarah.jordan@sanfordnc.net WASTEWATER MANAGEMENT FACILITY March 21,2022 Mr. Gray Hall Production Manager Trion,Incorporated 101 McNeill Road Sanford,NC 27330 Subject: Transmittal Letter for Industrial User Permit#000013 Dear Mr. Hall: Enclosed is modified Industrial User Permit 000013.Changes are as follows: 1. On pipe 01 the TTO sampling requirement for the City has been changed to"1 per twelve months providing the certification is not submitted"to align with other permits on the City of Sanford's pretreatment program. The modified pages included are 1,2, 3 and 6. Please add these modified pages to your current IUP. Remove the former pages and place them in a separate"historical"file and retain them for future reference. Please read this permit carefully,paying special attention to the changes referenced above. If any parts (measurement frequencies, sampling requirements,and/or limits)contained in this permit are unacceptable to you,you have the right to an adjudicatory hearing upon written request within thirty (30)days following the receipt of this letter. Unless such demand is made,this decision shall be final and binding. Sincerely, 564&41—' Sarah Jordan Pretreatment Coordinator City of Sanford CITY OF SANFORD Control Authority ardlor Municipality PERMIT Industrial User Pretreatment Permit(IUP) To Discharge Wastewater Under the Industrial Pretreatment Program 000013 433 IUP Number 40 CFR Category(A Applicable) In compliance with the provisions of North Carolina General Statute 143-215.1, any applicable federal categorical pretreatment regulations, all other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Control Authority and/or Municipality Sewer Use Ordinance. The following Industry hereafter referred to by name or as the permittee: Industry name.pernittee: ASC/TRION Facility Located at Street Address 101 McNeill Road City Sanford State,Zip North Carolina 27330 is hereby authorized to discharge wastewater from the facility located at the above listed address into the sanitary sewer collection system and the wastewater treatment facility of the Control Authority and/or Municipality listed below: IUP Control Authority and/or Municipality WWTP name: City of Sanford Big Buffalo Creek WWTP NPDES Number: NC 0024147 VVWiP Address' 5327 Iron Furnace Road City,State,Zip Sanford, North Carolina 27331-3729 in accordance with effluent limitations, monitoring requirements, and all other conditions set forth in Parts I, II, and III of this Industrial User Pretreatment Permit(IUP). Effective date. this permit and the authorization to discharge shall become effective at midnight on this date- March 21, 2022 Expiration date,this permit and the authorization to discharge shall expire at midnight on this date September 30, 2024 . 1,'D • ZZ. l .21 Data'g'� I hrcti oU Mc Works Industrial User Pretreatment Permit (IUP) PART I Specific Conditions IUP, PART I, OUTLINE: A.) IUP Basic Information B.) IUP Modification History C.) Authorization Statement D.) Description of Discharges E.) Schematic and Monitoring Locations F.) Effluent Limits & Monitoring Requirements G.) Definitions and Limit Page(s)notes A. IUP Basic Information: Receiving Control Authority&WWTP name: POTW NPDES#: City of Sanford Big Buffalo WWTP NC 0024147 Il it'Name: ItiP Number: ASC/Trion 000013 IUP Effective date: Pipe Numbers,list all regulated pipes: March 21, 2022 Pipe 01 & Pipe 02 IUP Expiration date: II JP 40 CFR#(if applicable),or N/A: September 30, 2024 40CFR 433 B. IUP History Effective Date Renewal or Modification Description of changes over previous IUP. 4/01/97 Modified Per DEM, changed the expiration date, added the option for the Industry to certify instead of sampling for Till D for the City to sample for Till annually if the Industry does not certify. 1D/1/DO Renewal The permit was renewed the effective and expiration date was changed. Part III,3 was modified to include calibrations of flow metering equipment to be completed by a nonaffiliated third party. B0D5 was removed from pipe 02. BM is no longer a surcharge parameter in the revised SOD. Aluminum monitoring was added to pipe 01. 3/12/02 Modified The monitoring frequencies were changed for Cd,NH3,and Al. 7/1/04 Modified The nickel limit was changed due to the new HWA. Detection limit for As, Cd,Cr,Cu, Cn, Pb, Ni,Ag,in, DEG, NH3, CBDD-5,Total Nitrogen,and Total P.was changed to ensure industrial compliance. 9/30/09 Renewal Changed flow limit,added parameters found in effluent and parameters that are required for LIMP 12/1/D9 Modified Added previous history,changed the detection limit for Cd&in,dropped the requirement for the industry to sample for in,added chlorides to the industry's monitoring requirement,and changed the wording of the flow monitoring requirements. 4/1/10 Modified Changed the monitoring requirement for Hg from a grab sample to a Composite sample and removed PERCS guidance from the IOP history. 2/22/2011 Modified Changed the TSS detection limit. 2 Industrial User Pretreatment Permit(IUP) PARTI Specific Conditions 09/30/2014 Renewal Permit Renewal.Bottom pH limit increased to 6.0 to comply with WWIP standard limits. 3/B/16 Modification Changed cyanide monitoring frequency to"1 per six months"for the City of Sanford POTW. 10/24/16 Modification Changed detection limit for chloride and changed"chlorides"to chloride on pipe 02 9/30/19 Renewal Permit Renewed for 5 years. 03/21/22 Modification Changed TT0 requirement for the City to"I per 12 months,providing the certification is not submitted"to align with other IUPs on the pretreatment program. C.) Authorization Statement: 1.) The Permittee is hereby authorized to discharge wastewater in accordance with the effluent limitations, monitoring requirements, and all other conditions set forth in this Industrial User Pretreatment Permit(IUP)into the sewer collection system and wastewater treatment facility of the Control Authority and/or Municipality. 2.) The Permittee is hereby authorized to continue operation of and discharge wastewater from the following treatment or pretreatment facilities. These facilities must correspond to the treatment units listed on both the application and inspection forms. IU Treatment Units List ali Treatment Units Descriptions: Spill Protection Pit and curbing Sump Pit Holding Tank 3.) The Permittee is hereby authorized to, if required by the Control Authority and/or Municipality and after receiving Authorization to Construct (A to C) from the Control Authority and/or Municipality, construct and operate additional pretreatment units as needed to meet final effluent limitations. D.) :se Description of IUP Discharge(s): g ( ) 1. Describe the discharge(s) from all regulated pipes. Pipe#01,Description of Discharge:Discharge consists of chemical rinse,powder wash system,liquid booth and liquid wash tanks. Pipe#02,Description of Discharge: Discharge from the sanitary sewer,pipe 01. 3 Receiving POTW name => Big Buffalo WWTP IU name => ASC/TRIDN IUP, Part 1 Section F: Receiving POTW NPDES#=> NC 0024147 IUP#=> 000013 Effluent Limits and Monitoring Requirements Effective date for these Limits=> March 21,2022 Pipe#=> 01 Expiration date for these Limits=> September 30,2024 40 CFR#=> 433 The Permittee may discharge from this specific if not applicable put N/A THE LIMITS ON THIS PAGE ARE,(Check one below): Pipe number according to these specific dates, LIMITS for ENTIRE permit period => X effluent limits, and monitoring requirements INTERIM Limits for period# 1 => INTERIM Limits for period#2 => FINAL Limits Page => Concentration Limits Monitoring Frequency Required Sample Laboratory Collection Detection Method Level in Daily Max Units _ By Industry By City (C or G) mg/I I Flow MGD Daily&Each Composite Sampling Event Each Composite Sampling Event Metered 2 Arsenic mg/I I per six months Composite .005 3 Cadmium 0.05 mg/I 1per six months 4 per six months Composite .002 4 Chloride mg/I I per six months Grab 10.0 5 Chromium 1.50 mg/I 4 per six months Composite .005 6 Copper 1.42 mg/I 4 per six months Composite .005 7 Cyanide 0.15 mg/I 4 per six months I per six months Grab .01 8 Lead 0.30 mg/I 4 per six months Composite .005 9 Mercury mg/I 2 per six months Composite .0002 1 10 Nickel 0.50 mg/I 4 per six months Composite .005 II pH(Range Min./Max.) 6.0-10.5 Std.Units 4 per six months Grab Std.Units 12 Silver 0.24 mg/I 4 per six months Composite .005 13 Temperature 66 °C 4 per six months Instantaneous °C 14 Toluene mg/I I per six months Grab 0.01 15 TTD 2.13 mg/I I per six months I per twelve months providing the certification is not Grab submitted 16 Zinc 1.24 mg/I 4 per six months Composite 0.01 17 Xylene mg/I I per six months Grab 0.01 18 6