Loading...
HomeMy WebLinkAboutSWG040136_Plansheet - Proposed Conditions/Site Plan_20220113DocuSign Envelope ID: 535BCA73-822C-4E9A-A8E8-6FFAF2AE543A DocuSign Envelope ID: 535BCA73-822C-4E9A-A8E8-6FFAF2AE543A TRA008 SEWERLINE EXTENSION, WATERLINE EXTENSION, & SEWER PUMP STATION i I — ," WILSUN MILL UMLLK MIA Vc? \`' �c) IF YOU DIG NORTH CAROLINA CALL US FIRST! d 811 111 N.C. ONE CALL CENTER IT'S THE LAW! FORCE MAIN 'A' & WATERLINE 'T' 131+00 13111 +50 13 +00 132+50 133CO. 133CO 134+00 134+50 13511 +00 135+50 136+00 136+20 219 11 11 11 11 2190 r STA.132+82 a� 12' STUB -OUT FOR FUTURE CONNECTION 4 .i [m FPk W e"i W 1- 12"X12" TEE F W 12" DIP CLASS 350 WATER LINE s,��r��p � � 2 - 12 G.V. &BOX 1 - 12 END OF LINE PLUG � 5' MINA_ 218 2185 STA.131+88 1 12" 45° MJ BEND / WATER LINE PROFILE 5 MIN STA 131+37 1 - 12 45° MJ BEND STA. 131+96 MIN. S COVER NOT �4l OI'Of>I:F 1 - 12" 45° MJ BEND (TYP.) OWN BEYOND THIS C,It/r�l PO 2 - 16" CASINGS INSTALLED BY GUIDED AUGER \^" MAINTAIN 18" SEPARATION UNTIL FOR CLARITY BORE. INSTALL BOTH CASINGS AT SAME HORIZONTAL SEPARATION IS REACHED ELEVATION AND GRADE. FORCE MAIN CASING SHALL HAVE 6" DIP CARRIER PIPE. WATER 218 MIN. 18"SEPARATION —ty CASING SHALL HAVE 2" PVC CARRIER PIPE. 2180 STA.131+49 74 1 - 6" 45° MJ BEND 7STA.131 SEE PUMP STATION $4 SHEETS FOR " 45° MJ BEND (WATER) WATER/SEWER 1 -645° MJ BEND (SEWER) STA. 133+04 ---11 MIN.3 COVER CONTINUATION 12 45° MJ BEND (WATER) 217 6 PVC SDR 21 1 6 45° MJ BEND (SEWER) 2175 FORCE MAIN C STREAA STREAM M CROSSING 6" PVC SDR 21 FORCE MAIN 217 2170 131+50 132+00 132+50 133+00 133150 134+00 134+50 135+00 135150 136+00 136+20 (STA. 131 +00 TO END) H. SCALE: 1 "=50' V. SCALE: 1 "=5' STA 120+00 TO 136+18 SCALE: 1 "=50' 50' 25' 0 50' 100, 150' GRAPHIC SCALE SCALE 1 " = 50' 12" END OF LINE PLUG -- - F— O � m F- 12" G.V. & BOX W 0 (SEE TYP. VALVE CONFIGURATION DETAIL) 1 b 12, 12.w --- - 12"X12" TEE 12" G.V. & BOX (SEE TYP. VALVE 12" DIP CLASS CONFIGURATION DETAIL) 350 WATER MAIN TYP. STUB -OUT CONNECTION NOT TO SCALE 12"W 12"W — 12" DIP CLASS 350 WATER MAIN FIRE HYDRANT (SEE FIRE HYDRANT ASSEMBLY DETAIL) 6" G.V. & BOX 12" G.V. & BOX (IF SPECIFIED 1 12"W 12"X6" TEE TYP. FIRE HYDRANT ASSEMBLY CONNECTION NOT TO SCALE SUPPLY SUPPLY DEAD END DEAD STA. 134+12 LIMIT OF BEGIN WATERLINE'U' DISTURBANCE 2 PVC SO 21 ' FORCE MAIN W 1 12"X6" TEE 6" PVC SO 21 1 6' MJ PLUG TAPPED 2" STA. 134+20 STA. 134+00 1 12" G.V. & BOX END WATERLINE'T' WATERLINE'T 1 - 6" 90° MJ BEND 1 - 2" G.V.& BOX 1 - 12" END OF LINE PLUG 12" DIP CLASS 350 (SEWER) T�,A,el"�W 12 I \\\IIIIIIIII IIIIIIII�IIIIIIIIIII I IIIIIIII III 6'FM � 8'FM IIIIIIIIIIIIIIIIIIIIIIIIIII 134 II\\IIIIIIIIIII\\\ \\ I III I ' FLAN STA.133+95 1 - F.H. ASSEMBLY 1 - 12"X6" TEE _ DEAD END TWO VALVES AT A TEE DEAD END DEAD END NOTES: 1. WHEN THERE IS ONLY ONE SUPPLYAND THREE DEAD END LEGS, PLACE VALVES ON DEAD END LEGS 2. WHEN THERE ARE THREE SUPPLY LEGS AND ONE DEAD END LEG, PLACE VALVES ON SUPPLY LEGS. 3. WHEN THERE ARE TWO SUPPLY LEGS AND TWO DEAD END LEGS, PLACE VALVES ON ALL FOUR LEGS. 4. WHEN ONE LEG AT AN INTERSECTION IS A HYDRANT LEG, VALVE MUST BE PLACED ON A HYDRANT LEG. VALVING ON REMAINING LEGS TO BE PLACED AS THOUGH THEY MAKE UP A TEE. 5. A "SUPPLY LEG" IS CONNECTED TO THE TREATED WATER SOURCE BY PIPING EQUAL AND OR GRATER THAN ITS SIZE AND SEPARATE FROM THE TEE OR CROSS BEING CONSIDERED. STA.134+07 J ` STA.0+08 BEGIN BORE & JACK (SEWER) BEGIN BORE & JACK (WATER) 16" CASING BY 16" CASING BY GUIDED AUGER BORE GUIDED AUGER BORE INSET'F' ROSMAN HwY. (US-64) SCALE: V=10' DEAD END DEAD THREE AND FOUR VALVES AT AN INTERSECTION TYPICAL VALVE CONFIGURATION NOT TO SCALE NOTES: 1. WHEN THERE IS ONLY ONE SUPPLY LEG FEEDING TWO DEAD END LEGS, PLACE VALVES ON DEAD END LEGS. 2. WHEN THERE ARE TWO SUPPLY LEGS FEEDING ONE DEAD END LEG, PLACE VALVES ON SUPPLY LEGS. 3. WHEN ALL THREE LEGS ARE SUPPLY, ENGINEER'S CHOICE. 4. ON HYDRANT TEE, ONE VALVE IS ALWAYS ON HYDRANT LEG. DEAD DEAD END U Uj W r o N r O N Q o LO pp cM W W z C� W Z W U J ry Q U 00 °O H C-4 0c) LL ofry W O H Z ch Z M W U O U = J J w O z = Q U Z \\\0 \\\1tIIIIIIIIIII//////7�/i 7S213ECI 19A944FS AL 23927 N J ONE\\\\�. 12/14/2021 ////m*N I w\\\\ Z z z O O O ZC0 ~ z � �� W O W O U zQ X ' ` Q J W W L z W W Q 0 Q Z Z > J cu J J W c W W W Q~ Q c LU 3: V ! Z z � O E w QC o CC N w O Q � a > `o w m m m C 0 m E cn w QCD CD 0 m v 01111116, xk Q m PROJECT NAME: SEWERLINE EXTENSION WATERLINE EXTENSION AND SEWER PUMP STATION Transylvania County, NC SHEET TITLE: FORCE MAIN 'A' & WATERLINE 'T' (STA. 120+00 TO 136+18) PROJECT NO. SHEET NO. TRA008 DATE: C-6 10/13/2021 of 17 ISSUE No. A-2 DocuSign Envelope ID: 535BCA73-822C-4E9A-A8E8-6FFAF2AE543A