Loading...
HomeMy WebLinkAboutSW7961115_APPROVED PLANS_20170814STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. Sw_7?ce /� DOC TYPE ❑ CURRENT PERMIT APPROVED PLANS ❑ HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE YYYYMMDD VICINITY MAP N TS I EXGE BUILDING w, x I EX. STORAGE ---- J o x w BUILDING I EX. STORAGE I I _ I N/F - _ - - - - - - J I _ BUILDING J EX. STORMWATER I MCLEOD FOUNDATION INC z ivo o �_-_ 0 w u I POND ( D.B. 1094, PG. 127 I = Q CARPET & APPLIANCE PLAZA INC. \\ / I PIN: 892317019099 N/F �I D.B. 846, Px �/ CURRENT USE: FAMIILBY PIN: 892317O17018 DOLLAR STORE KITTY HAWK ASSOCIATES LLC EX. SAN. MH " 9201q �' C/O WHEELER INT INC RIM = 7.60 ZONED: 1-1 D.B. 1038, PG. 24 INV - 2.75 CURRENT USE: STORAGE FACILITY R M = 7.77 N.H PIN: 892317003542 INV = 2.11 - - - — ZONED: 1-1 ... _- —� CURRENT USE: FRISKIES PET CARE PRODUCTS N57' 19 28"E 345, 89' - _ -- - -- _-- -- -- -- --- - - _ -_ _----- - 2757' 19' 28"E- — PGA ` - - �,. _ 15 BUILDING SETBACK -- --_ - - _ _ \ 6>� O El -� EX. CUSTOMER `L 160 \ADVISORY SIGN -D- _-=_ --_� _ ___ _ _ _. -- 457 SQ. FT. CURBED_ APPROX_ ___-.... -- -_. _ .._ & SCREENED- DUMPSTER PAD DRAIN . LOCATION EX. 12" SEWER �- - DUMPSTER PAD �, - RIM = 8.25 5 J — \ _ .-EX­20�3EWER EL$ELENT _ \ — -tom APPRO EX. 40' DRAINAGE EASEMENT EX. SAN. MH a1 - _-�"p,PS -'', - - - - - - %- - - - - EX - - X. LOCATION EX. 12 SEWER - - -.—.-.- (APPROX. LOCATION) . /pSF'� �SE�� /� - _ _ _ ., - - - - SAN. M - . - _ - - . - . - . - . - . EX., 20' S WER EA - H OIL/WATER/ I I RIM = 8.34 . r' �EMENT_I� __ _ _ _ EX. NO LEFT SAND SEPERAT IR I '- TURN SIGN px''N\ / SMALL DI I W- I I f - - — - '-,ry1' �/ E CLEARED OF,..., . UTFALL TO\ I / \ _NIV = 6.00 I 1 CONC.O+ I 69 I Ifr I I EX. ONE WAY _ I I- 30 6 HEAVY VEGETATION NASHPAEI _ _ F SIGN I III O- e„ (PERM. GPOOLRELEVTER 3S0) 29 --EX. WASH TEMPORARY BM —I I� PAD CANOPY EX. GONG. y� " (NAIL IN PVMT) — b 1 OVERHANG VACUUM }{ ELEV = 8.90 PAD 72 I II 124 a' zF SEAL COAT BLACK Ix a I OVER PARKING LINES I — w FOR SPACES TO BE �I REMOVED EX. NE o0 _ —. RETAIL BUILDING SIGN O AY 125 �' to I I EXISTING 9600 SQ. FT I o X I _ F4pFO \ ' SEAL COAT BLACK I _ S TO BE OVER PARKING LIN FOR SPACE ES I I REMOVED — � I AS Sim = Im \ I ° UNDERGROUND I LP in o I I— —1 TANK I I I m — r- SEAL COAT BLACK ------- PARKING LINES' 3: EXISTING I 17 m REMOVE WHOPS _ 132 FOR SPACES -TO Bt"_y N H YPC UNITS i o-"�i I a V) I REMOVED 'I 1 " w — �— ) I o I I II--_---- 133Ir----_-- 16 I N r=n I o-D,J z A— Y I'I REMOVE WHEEL STOP I I I = & RE -STRIPE AS �, I m �----`- SHOWN ON_=O - - "� I I 0I 09I — 106 II — - � i Q EXISTING 9600 SQ. FT. I RETAIL BUILDING Z w I ul, 105 o r- Io 140 ,... a I I III r m I� 141Ip RE -STRIPE AS 200 r=*rn SHOWN ON C 0 - k zGAS I REMOVE WHEEL STOP a .I LCO Iw IF & RE -STRIPE AS 11 _I_ I EXISTING SHOWN ON_=O--1 '' I HVAC UNITS I . G. I— I (TYP.) 95 -� � II I m o �--L--------- — ' L--------- ss I I , wa I I zo I toU I I148 96 -----I� i L_20' BUILDING SETBACK ------- --- I S55' 15' LANDSCAPE BUFFER _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _'_- _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _--------20' 41"I L_ _ _ _ _-- ___ .' i EX. ONE WAY EX. WRONG \ a m x � I SIGN I WAY SIGN N: a I Cy3 S55' 20' 41"W 387.23' _______`W _W :. w :: w - W :: : „—___Wt_ w W W ---W W W W =W— APPROX. LOCATION EX. 10" WATERLINE II - - --- -- INDUSTRIAL PARK DR. -- -- ---- ---- (80' R/W)/SR-1206 - — — — — II N/F CONSOLIDATED, EVELOPMENT CONSOLIDATED DEVELOPMENT \ 896 D.B. 527, PG. / PIN: 1-1 I�896 PIN: 892317103416 ZONED: 101 NEED: 1 — CURRENT USE: VACANT _ _ _ CURRENT USE: ELECTRICC SUPPLIES INC. - -ZONED: - - - - rqS57' 19' 28"W 182.95' EX. ONE WAY SIG I i EX. WRONG WAY SIGN - -=T- IN w IN -y— v': iN wy: W is W W _ N SITE DATA: 1. OWNER/DEVELOPER: HOFFER PROPERTIES, LLC KENNETH HOFFER, MANAGER 107 KITTY HAWK LN ELIZABETH CITY, NO 27906 (252) 331-1997 2. SITE INFORMATION: PIN # 892317100721 & 892317101886 D.B. 738, PG. 302 TAX MAP:P122-40 & 40A LOT i OF ELIZABETH CITY/PASQUOTANK COUNTY INDUSTRIAL PARK (M.B. 7, PG. 50) SITE AREA: 244,890 SF = 5.62 AC. (TOTAL) DISTURBED AREA = 16,598 SF = 0.38 AC. ZONING: GB - GENERAL BUSINESS ADDRESS: 102 INDUSTRIAL PARK DR. 3. MINIMUM BUILDING SETBACKS: STREET = 20' (INDUSTRIAL PARK DR.) STREET = 20' (KITTY HAWK LN.) REAR = 15' 4. SITE IS LOCATED IN FLOOD HAZARD ZONE SHADED "X" AND "X" AS SHOWN ON F.I.R.M. PANEL 3720892300J, DATED OCTOBER 5, 2004. 5. THIS IS NOT A BOUNDARY SURVEY. BOUNDARY LIMITS SHOWN TAKEN FROM PLAT ENTITLED "FINAL PLAT FOR ELIZABETH CITY INDUSTRIAL PARK", PREPARED BY WILLIAM & WORKS, ROBERT J. BRACKEN, PLS; DATED JUNE 02, 1977. 6. EXISTING IMPROVEMENTS SHOWN HEREON TAKEN FROM SITE PLAN BY HYMAN & ROBEY DATED DECEMBER 4, 2013 AND ADJUSTED BASED ON VISUAL INSPECTION AND AERIAL PHOTOGRAPHY. LEGEND _J EXISTING ASPHALT PAVEMENT C - EXISTING CONCRETE/SIDEWALK EXISTING RIPRAP PROPERTY LINE - - PROPERTY LINE EXTENSION - - - - - - - - - BUILDING SETBACK - - - - - - - - - - - - - - - - - BUFFER YARD SETBACK - - RIGHT OF WAY LINE --- -- -_ - - - - -- UTILITY EASEMENT - - FLOODZONE BOUNDARY W W W EXISTING WATERLINE _ = EXISTING STORM CULVERT - - EXISTING SEWER LINE CHEZ,HE EXISTING OVERHEAD ELECTRIC SAS -SAS EXISTING GAS LINE X X EXISTING FENCE X X --- ---- - -- EXISTING TOP OF BANK ---- - - - - ---- - ----- EXISTING TOE OF BANK - - - - EXISTING DITCH/SWALE EXISTING POND PERMANENT POOL EXISTING LANDSCAPED/MULCHED AREA TEMPORARY BENCHMARK EXISTING FIRE HYDRANT D4 EXISTING WATER VALVE D4 EXISTING WATER BLOWOFF Y EXISTING YARD HYDRANT D4 EXISTING GAS VALVE ® EXISTING SEWER MANHOLE �Qn EXISTING UTILITY POLE EXISTING DROP INLET 4W EXISTING CURB INLET EXISTING STORMWATER FLOW DIRECTION EXISTING BOLLARD �co EXISTING SEWER CLEANOUT >$ EXISTING POLE LIGHT EXISTING SHRUB EXISTING MAPLE EXISTING CREPE MYRTLE EXISTING LACEBARK ELM ME O r C~9 O ` Q ■ _ GoeWr rA O C% QCV mud C4 W 0 � W � \ Won ei �..� O O N LU W �R ° 0 Y ZO Z Q _� i-Z W U)a OJ UQ_ja° X aLLJ W = f— p� U) �- �O ___I 0 U Z OYom _ W T­ IN Q 0- J W 1 w7 9(o Its 000 t.i Zd' bete — O a U WUJ 0 GRAPHIC SCALE 0 15 30 60 ( IN FEET ) 1 inch = 30 it. W Z p O AUG - 9 2017 U w Z) - 2 Z r 120 ` U) ZOO O C:)w W F `^ VJ Q W Q w Know what's b@IOW, W ZO ozs = U Call before you dig. 1: 0 6. PARKING REQUIREMENTS: TOTAL = EXISTING + PROPOSED NEW VEHICULAR SURFACE AREA: BUILDING AREA = 19 200 SF - - SITE DATA: - 97,121 + 13,486 - 104,607 SF TOTAL NEW VEHICULAR SURFACE AREA - - 13,326 SF REQUIRED PARKING ® 1/200 SF GROSS FLOOR AREA = 96 = 2.40 AC 1. OWNER/DEVELOPER: HOFFER PROPERTIES, LLC EXISTING REGULAR SPACES PROVIDED = 144 = 42.7% IMPERVIOUS REDID SHADING = 1 CANOPY TREE EVERY 2000 SF KENNETH HOFFER, MANAGER EXISTING ADA SPACES = 4 (42.9% ALLOWED BY PERMIT 1 SHRUB EVERY 500 SF 107 KITTY HAWK LN TOTAL EXISTING SPACES = 148 9. LANDSCAPING REQUIREMENTS FOR PARKING AREAS: - ELIZABETH CITY, NC 27906 U 13,326/2000 - 7 CANOPY TREES REQ D EXISTING SPACES TO BE REMOVED FOR IMPROVEMENTS = 4 13 326 500 = 27 SHRUBS RE 'D (252) 331-1997 / Q EXISTING SPACES TO BE CONVERTED TO ADA = 3 ANY LANDSCAPING NOT INSTALLED WITH PREVIOUS PHASE TO BE 2. SITE INFORMATION: PIN 111 892PC. 302 0721 & 892317101886 EXISTING SPACES TO BE REMOVED FOR ADA AISLE = 4 INSTALLED AS A PART OF THIS PHASE OF CONSTRUCTION. LANDSCAPE ISLANDS: 1 ISLAND AND 1 CANOPY TREE PER EVERY D.B. 738, PG. PROPOSED ADDITIONAL REGULAR SPACES = 33 TAX MAP: P122-40 & 40A TOTAL REGULAR PARKING SPACES PROVIDED = 166 STREETSIDE BUFFER: 10 PARKING SPACES %v TOTAL ADA PARKING SPACES PROVIDED = 7 - REQ'D BUFFER - 1 CANOPY TREE PER 50 LINEAR FEET OF 33 SPACES 10 = 3 ISLANDS RE '0 COUNTY INDUSTRIAL PARK (M.B. 7, PG. 50) STREET FRONTAGE LOT 1 OF ELIZABETH CITY/PASQUOTANK TOTAL PARKING SPACES AT COMPLETION OF EXPANSION = 173 / Q SITE AREA: 244,890 SF = 5,62 AC. (TOTAL) 7. THERE ARE NO WETLANDS WITHIN THE PROJECT LIMITS. SHRUBS PLANTED 4' ON CENTER TOTAL TREES REQUIRED = 10 DISTURBED AREA = 16,598 SF = 0.38 AC. TOTAL TREES PROVIDED = 10 ZONING: GB - GENERAL BUSINESS 8. SITE COVERAGE: STREET FRONTAGE: TOTAL SHRUBS REQUIRED = 27 ADDRESS: 102 INDUSTRIAL PARK DR. TOTAL SHRUBS PROVIDED = 27 INDUSTRIAL PARK DR. = 200 LF - 48 LF OF DRIVEWAY OR 152 LF VICINITY MAP EXISTING ON -SITE IMPERVIOUS: - STREET TREES REQUIRED = 152/50 = 3 CANOPY TREES LANDSCAPED AREAS IMMEDIATELY ADJACENT TO SHRUBS 3. MINIMUM BUILDING SETBACKS: STREET = 20' (INDUSTRIAL PARK DR.) EXISTING BUILDING & CAR CANOPY 20,087 SF STREET TREES PROVIDED = 5 (3 EXISTING) SHALL BE MULCHED AND REMAINING AREAS SHALL BE STREET = 20'(KITTY HAWK LN.) EXISTING ASPHALT = 64,511 SF STREET SHRUBS REQUIRED = 152/4 = 38 SHRUBS GRASS GROUND COVER. ALL OTHER OPEN AREAS SHALL NTS REAR = 15' EXISTING CONCRETE = 6,523 SF AL N IM VI A = 91, STREET SHRUBS PROVIDED = 38 BE SEEDED OR SOD AND STABILIZED PER THE SEEDING SCHEDULE. TOT4. SITE IS LOCATED IN FLOOD HAZARD ZONE SHADED "X" AND "X" AS SHOWN ON = 2.09 AC NO STREETSCAPING IS REQUIRED ALONG KITTY HAWK LN. FOR THIS LANDSCAPING MUST BE INSTALLED AS SHOWN ON THIS F.I.R.M. PANEL 3720892300J, DATED OCTOBER 5, 2004. = 37.2% IMPERVIOUS PROJECT; HOWEVER STREETSCAPING WILL BE REQUIRED AT THE TIME OF PLAN. CHANGES MUST BE APPROVED BY THE CITY OF 5. THIS IS NOT A BOUNDARY SURVEY. BOUNDARY LIMITS SHOWN TAKEN FROM PROPOSED SITE COVERAGE BREAKDOWN FOR PROJECT: FUTURE DEVELOPMENT. ELIZABETH CITY DEPARTMENT PLANNING &COMMUNITY PLAT ENTITLED "FINAL PLAT FOR ELIZABETH CITY INDUSTRIAL PARK", PREPARED PROPOSED ASPHALT = 13,326 SF DEVELOPMENT PRIOR TO INSTALLLL ATION. BY WILLIAM & WORKS, ROBERT J. BRACKEN, PLS; DATED JUNE 02, 1977. PROPOSED CONCRETE = 160 SF REQUIRED LANDSCAPING SHALL NOT BE PLANTED IN THE NIL IMPEKVOUb AKEA13,486 SF NCDOT RIGHT-OF-WAY. = 0.31 AC IEX. STORAGE I x I EX. STORAGE I (I I II II I I 4 IIII BUILDING- I �"' I BUILDING I EX. STORAGE I I N F II J z a z - _ BUILDING I EX. STORMWATER / o= y 1 0 oN ` - -J N/F / I I MCLEOD FOUNDATION INC _ _ POND D.B. 1094, PG. 127 N/F = o CARPET & APPLIANCE PLAZA INC. PIN: 892317019099 II I I IIII D.B. 846, PG. 327 � I ZONED: GB & 1-1 I 1 KITTY HAWK ASSOCIATES LLC I EX. SAN. MH PIN: 892317017018 \� CURRENT USE: FAMILY DOLLAR STORE C/O WHEELER INT INC RIM = 7.60 ZONED: 1-1 INV = 2.75 CURRENT USE: STORAGE FACILITY EX. SAN. MH i D.B. 1038, PG. 24 / RIM - 7.77 L- _ PIN: 892317003542 INV=2.11 J-----------------) II ZONED: 1-1 __ _ -y CURRENT USE: FRISKIES PET CARE PRODUCTS- - ------- -__ _ _ N57' 19 28'E 345 89' --_ N57' 19' 28"E -- - ---_ _ - _ - 21 O TO - - _ 15_BUILOING SETBACK '�-- ---- __ _ _ s - \ 6\ 8 \ E\ \ 60 ADVISORYSIGNI) _ - -- SO. FT CURBED_ \-+= - _ _ _._ SCREENED _ _ DUMPSTER P DRAINS . 0 -� EX I I APPROK LOCATION EX. 12" SEWER - - DUMPSTER PAD -"- / RIM = 8.25 D /` -EX_20_SE`b�R EASEWNT - /EX 40' DRAINAGE EASE ENT _ \ _ . _-._.-.- -- AD--�.-X. LOCATION E� SEWER \ � I EX. SAN. MH ?� -/'�, - - - - ._.-.-._.- 20 SE M - (APPROX. LOCATION) RIM = 8.34H EX. '. 1VER EASEMENT _ _ I ��11-- /Ei� y01L/WATER/ I I __ EX. NO LEFT SAND SEPERATOR i - - SIGN r � TURN I I ��.• dppP / `,, / \ 114 SMALL DI-- © _ _ I F-- - - - - - -I -MV = 6.00 I 1 ' X 301 69 1 Ik EX. ONE WAY 30 EXISTING STORMWATER POND WASHPAd 4� SIGN (PERM. POOL ELEV. = 3.50) I 11 I oil I- 29 I I. ` 1r WASH �- - - YI ` TEMPORARY BM _ I' PAD CANOPY B0 e I I 1 1 ` \ OVERHANG E VACUUM (NAIL IN PVMT) PAD 71 ELEV = 8.90 I I 1�=20 i IX > I I l I I ! _ �\00 \ - _ - ' -__ . -. SIGN NE 1 - ! _ � � ��"� EX. "0 WAY OOO SON sh _ - 121 I I EXISTING RETA9B00 SQ. FT. I I I I I 1 I II 1 173 �� : AS SI �z m \ O� • 72 UNDERGROUND I m i•9 r LP TANK I I n I > �y w I I 1 0 iCm 126 q ¢- II II - JIF T I I iA z 159 8 ,STANDUP # I I ,' 3 I I 17 I "o r� III Cl� - CURB {T'cP.} I 'I Uj fIn I��--}X I I (YAPC)UNITSEXISTING / - I a II I� - • I g - - Z tI -2I IIII > 1 5R ® �p^ `� -- -_ � � v'z I __-__- w O i �� j 154 1� ,27 a Y-- r-- z & I I I OV 16-I I m> IIII .I I vM �4' SIDEWALK 5 I M I fat V I mo¢ I I I I y I I I M t 102 I I > III - II L� I EXISTING 9600 SQ. �. RETAIL BUILDING -I 4 z Im ADA SIG 1 I I I I w I 701 O (5250 FIN) I m I - -I NIm sip i I I ii I- - 1> izQADA N 133 I ( N W (S250 rrFONE} I I III Uj Uj0 a I I 147 I� 134 �- o I¢ �I I �1 I 1 1 - - CbNC..- I� PARN,NG �- x N 41 -� 2D' TYP.1 � 6 �S I; j( lice - I F i I,=,_," ADA SIGN _ I n 24' I i I �� �- g ($250 FIN Q) �' I� I I N 1 II.h /� EXISTING I I I tO''IYP. `2 '� 4' SIDEWALK I rv, �T PC)UNITS L_ - _ \� I,I I II = JIB 1 J - I I I- 1 I I 11 II _ I m I 1 o to I I 1 -- `�97-)`---------JI I 59 -L 1 I I 1 773------- - wI IU _ • « 147 140 _--- 92 z I L 20' BUILDING SETBACK - -; - - - - - 9'R aW 15' LANDSCAPE BUFFER _ _ _ _ _ _ _ _ _ _ _ - - - - - - - - '>J S55' 20' 41"W L ----- - - - - - - - - - - - - - :- � - - - _30.07' EX. ONEX. WRONG o I WAY SIGN m a Oq S55' 20' 41"W 387.23' ;. / a ` 'j SST 79' 28"W 182.95' - a EX. ONE WAY SIGN I / SV SV -` SVISVJf_SV m L�'­­--w \ EX. WRONG WAY SIGN W-=ir'r'Ir'r W yrry n--W W�W �'r v> rr rrW-ri Wvr' WI: W n--vr' rVWriirW-kdr✓r'r APPROX. LOCATION EX. 10" WATERLINE ALL CQQMMSTRUQT,QN TRAFFIC TO-7' O INDUSTRIAL PARK DR. (80' R/UV)/SR-1206 INFi1tES RUCTIONS THROUGH STRUCTION ENTRANCE CONSOLIDATED DEVELOPMENT I N/F / �- 1 D.B. 527, PG. 896 CONSOLIDATED DEVELOPMENT / PIN: 892317101350 D.B. 527, P�- ZONED: -1 II PIN: 8923171 41 -1 _CURRENT USE: VACANT_ _ - - _ - -ZONED: 1(/ CURRENT USE: ELECTRICC SUPPLIES INC. 30 10. SIGNAGE MUST BE APPROVED AND PERMIT ISSUED BY THE CITY OF ELIZABETH CITY DEPARTMENT OF PLANNING & COMMUNITY DEVELOPMENT PRIOR TO INSTALLATION. 11. ALL UTILITY CONNECTIONS SHALL CONFORM TO THE CITY OF ELIZABETH CITY STANDARDS AND SHALL BE COORDINATED WITH THE CITY OF ELIZABETH CITY PUBLIC WORKS DEPARTMENT. EXISTING UTILITY CONNECTIONS SHALL BE UTILIZED. 12. CONTRACTOR SHALL INSPECT AND MAINTAIN AS NEEDED ALL EROSION CONTROL DEVICES ON A WEEKLY BASIS AND AFTER EACH MAJOR STORM EVENT. FAILURE TO KEEP EROSION CONTROL DEVICES IN GOOD WORKING ORDER MAY RESULT IN THE ISSUANCE OF A STOP WORK ORDER. 13. ANY FILL BROUGHT ON SITE SHALL BE FROM AN APPROVED SITE/MINE. ANY MATERIAL REMOVED FROM THE SITE SHALL BE DISPOSED OF IN A SINGLE APPROVED LOCATION. 14. DISTURBED AREA WILL NOT EXCEED 0.60 ACRES. 15. OFF -SITE PARKING, LOADING AND UNLOADING IN RIGHT OF WAY IS PROHIBITED. 16. NO EXTERIOR STORAGE CONTAINERS, BUILDINGS, ENCLOSURES, ETC. SHALL BE ERECTED ON THIS SITE WITHOUT PRIOR APPROVAL FROM THE CITY OF ELIZABETH CITY DEPARTMENT OF PLANNING & COMMUNITY DEVELOPMENT. 17. ALL STORAGE BINS, TRASH RECEPTACLES, AND RECYCLE CONTAINERS SHALL BE SCREENED. 18. THE CONTRACTOR SHALL VERIFY THE EXISTENCE, SIZE, DEPTH, MATERIAL, LOCATION, AND CONDITIONS OF ALL UTILITIES (PUBLIC AND PRIVATE) PRIOR TO ANY EXCAVATION OR CONSTRUCTION WORK. THE CONTRACTOR IS REQUIRED TO CONTACT (NC ONE CALL) AT 811 AND ALL POTENTIAL UTILITY OWNERS PRIOR TO EXCAVATION IN ACCORDANCE WITH NORTH CAROLINA LAW GOVERNING SUCH WORK. IF THE CONTRACTOR DETERMINES A CONFLICT EXISTS THAT MAY ADVERSELY AFFECT THE PROPOSED WORK, THE OWNER IS TO BE NOTIFIED PRIOR TO PROCEEDING WITH ANY CONSTRUCTION WORK. LEGEND PROPOSED MAPLE (14) (LANDSCAPE CONTRACTOR TO MATCH PROPOSED MAPLES TO EXISTING MAPLE SPECIES) PROPOSED LACEBARK ELM (5) (171 parifolia) ALL CANOPY TREES TO BE A MINIMUM OF 8' TALL WITH A 2" CALIPER, MEASURED 6" ABOVE GRADE PROPOSED INDIAN HAWTHORN ELEANOR TABER (56) (Rhaphiolepis indica 'Connr') PROPOSED LOROPETALUM 'DARUMA' DWARF (37) (Loropetalum chinansis 'dame ')) ALL SHRUBS TO BE A MINIMUM OF 12" TO 18" TALL / 3 GALLON SIZE AT THE TIME OF PLANTING NOTE: ALL LANDSCAPED AREAS TO BE COVERED WITH 4" HARDWOOD MULCH. ALL OTHER UNIMPROVED AREAS TO BE SEEDED PER SEEDING AND MULCHING DETAIL ON SHEET C902. LEGEND L_ -J EXISTING ASPHALT PAVEMENT -: PROPOSED ASPHALT PAVEMENT EXISTING SIDEWALK/CONCRETE PROPOSED CONCRETE/SIDEWALK EXISTING RIPRAP PROPERTY LINE _ - PROPERTY LINE EXTENSION - BUILDING SETBACK - - - - - - - - - - - - - - - - BUFFER YARD SETBACK - - RIGHT OF WAY LINE --- - -- - - --- - - UTILITY EASEMENT - - FLOODZONE BOUNDARY W-.'J W EXISTING WATERLINE _ = EXISTING STORM CULVERT - -�- - EXISTING SEWER LINE --OHE-SHE EXISTING OVERHEAD ELECTRIC -GAS AS EXISTING GAS LINE X EXISTING FENCE X X X -- _---- - - --- - ------ EXISTING TOP OF BANK - -_-- -- ----------- PROPOSED TOP OF BANK -- - _ -- - - - - -- - ---- EXISTING TOE OF BANK - EXISTING DITCH/SWALE EXISTING POND PERMANENT POOL EXISTING LANDSCAPED/MULCHED AREA TEMPORARY BENCHMARK Ayb EXISTING FIRE HYDRANT D4 EXISTING WATER VALVE 90 D4 EXISTING WATER BLOWOFF `•° EXISTING YARD HYDRANT D4 EXISTING GAS VALVE ® EXISTING SEWER MANHOLE EXISTING UTILITY POLE EXISTING POLE LIGHT EXISTING DROP INLET EXISTING CURB INLET EXISTING JUNCTION BOX EXISTING STORMWATER FLOW DIRECTION EXISTING BOLLARD 'Eco EXISTING SEWER CLEANOUT EXISTING SHRUB EXISTING MAPLE EXISTING CREPE MYRTLE EXISTING LACEBARK ELM N N rn n N U Z C W ma ✓_ m Y N N W 00 LIM 3 S Ln D a N S Qraft CD go 0 TM W CO Cm cc.*N `� C mmaiV �Ca W Ca 0W W Wok O O N LU I.L Q > W 10 LL� W O 0 Y z Q Q �Y/ z_ W W < O -j X a W = ILL IIII- 0 II_ O LL J 0 U z O ^ z F- O m N r- Q- J W GRAPHIC SCAL= LEGEND 15 30 60 LANDSCAPING 120 W F PROPOSED MAPLE (14) Vr y�,� ( IN FEET (LANDSCAPE CONTRACTOR TO MATCH what's below. j W N,ow 1 inch = 30 KAPLES TO EXISTING MAPLE SPECIE Call 4 before You dig. U PROPOSED LACEBARK ELM (5) (Mmu parifolia) ALL CANOPY TREES TO BE A MINIMUM OF 8' TALL WITH A 2" CALIPER, MEASURED 6" ABOVE GRADE T- 0 =Q =QNN 0 Cl) 011Q II t- U) 000N Cp O c N j ik o 3 m 3 2 c m m d 0 CL f]UQ��t�A W O 2 N W :D HzW U ��//�� VJ T 0) VICINITY MAP NTS SITE DATA: 1. OWNER/DEVELOPER: HOFFER PROPERTIES, LLC KENNETH HOFFER, MANAGER 107 KITTY HAWK LN ELIZABETH CITY, NO 27906 (252) 331-1997 2. SITE INFORMATION: PIN # 892317100721 & 892317101886 D.B. 738, PG. 302 TAX MAP:P122-40 & 40A LOT 1 OF ELIZABETH CITY/PASQUOTANK COUNTY INDUSTRIAL PARK (M.B. 7, PG. 50) SITE AREA: 244,890 SF = 5.62 AC. (TOTAL) DISTURBED AREA = 16,598 SF = 0.38 AC. ZONING: GB - GENERAL BUSINESS ADDRESS: 102 INDUSTRIAL PARK DR. 3. MINIMUM BUILDING SETBACKS: STREET = 20' (INDUSTRIAL PARK DR.) STREET = 20' KITTY HAWK LN. REAR = 15' 4. SITE IS LOCATED IN FLOOD HAZARD ZONE SHADED "X" AND "X" AS SHOWN ON F.I.R.M. PANEL 3720892300J, DATED OCTOBER 5, 2004. 5. THIS IS NOT A BOUNDARY SURVEY. BOUNDARY LIMITS SHOWN TAKEN FROM PLAT ENTITLED "FINAL PLAT FOR ELIZABETH CITY INDUSTRIAL PARK", PREPARED BY WILLIAM & WORKS, ROBERT J. BRACKEN, PLS; DATED JUNE 02, 1977. 6. PARKING REQUIREMENTS BUILDING AREA = 19,200 SF REQUIRED PARKING ® 1/200 SF GROSS FLOOR AREA = 96 EXISTING REGULAR SPACES PROVIDED = 144 EXISTING ADA SPACES = 4 TOTAL EXISTING SPACES = 148 EXISTING SPACES TO BE REMOVED FOR IMPROVEMENTS = 4 EXISTING SPACES TO BE CONVERTED TO ADA = 3 EXISTING SPACES TO BE REMOVED FOR ADA AISLE = 4 PROPOSED ADDITIONAL REGULAR SPACES = 33 TOTAL REGULAR PARKING SPACES PROVIDED = 166 TOTAL ADA PARKING SPACES PROVIDED = 7 TOTAL PARKING SPACES AT COMPLETION OF EXPANSION = 173 7. THERE ARE NO WETLANDS WITHIN THE PROJECT LIMITS. 8. SITE COVERAGE: EXISTING ON -SITE IMPERVIOUS: EXISTING BUILDING & CAR CANOPY = 20,087 SF EXISTING ASPHALT = 64,511 SF EXISTING CONCRETE = 6,523 SF TOIAL LXISIING IMPERVIOUS AREA91,121 SF = 2.09 AC = 37.2% IMPERVIOUS PROPOSED SITE COVERAGE BREAKDOWN FOR PROJECT: PROPOSED ASPHALT = 13,326 SF PROPOSED CONCRETE = 160 SF PROPOSED SITE IMPERVOUS AREA 13,486 0.31 AC TOTAL = EXISTING + PROPOSED = 91,121 + 13,486 = 104,607 SF = 2.40 AC 42.7% IMPERVIOUS (42.9% ALLOWED BY PERMIT 9. LANDSCAPING REQUIREMENTS FOR PARKING AREAS: `ANY LANDSCAPING NOT INSTALLED WITH PREVIOUS PHASE TO BE INSTALLED AS A PART OF THIS PHASE OF CONSTRUCTION. STREETSIDE BUFFER: REQ'D BUFFER = 1 CANOPY TREE PER 50 LINEAR FEET OF STREET FRONTAGE SHRUBS PLANTED 4' ON CENTER STREET FRONTAGE: INDUSTRIAL PARK DR. = 200 LF - 48 LF OF DRIVEWAY OR 152 LF STREET TREES REQUIRED = 152/50 = 3 CANOPY TREES STREET TREES PROVIDED = 5 (3 EXISTING) STREET SHRUBS REQUIRED = 152/4 = 38 SHRUBS STREET SHRUBS PROVIDED = 38 NO STREETSCAPING IS REQUIRED ALONG KITTY HAWK LN. FOR THIS PROJECT; HOWEVER STREETSCAPING WILL BE REQUIRED AT THE TIME OF FUTURE DEVELOPMENT. NEW VEHICULAR SURFACE AREA: TOTAL NEW VEHICULAR SURFACE AREA = 13,326 SF REQ'D SHADING = 1 CANOPY TREE EVERY 2000 SF , SHRUB EVERY 500 SF 13,326/2000 = 7 CANOPY TREES REQ'D 13,326/500 = 27 SHRUBS REQ'D LANDSCAPE ISLANDS: 1 ISLAND AND 1 CANOPY TREE PER EVERY 10 PARKING SPACES 33 SPACES/ 10 = 3 ISLANDS REQ'D TOTAL TREES REQUIRED = 10 TOTAL TREES PROVIDED = 10 TOTAL SHRUBS REQUIRED = 27 TOTAL SHRUBS PROVIDED = 27 LANDSCAPED AREAS IMMEDIATELY ADJACENT TO SHRUBS SHALL BE MULCHED AND REMAINING AREAS SHALL BE GRASS GROUND COVER. ALL OTHER OPEN AREAS SHALL BE SEEDED OR SOD AND STABILIZED PER THE SEEDING SCHEDULE LANDSCAPING MUST BE INSTALLED AS SHOWN ON THIS PLAN. CHANGES MUST BE APPROVED BY THE CITY OF ELIZABETH CITY DEPARTMENT OF PLANNING & COMMUNITY DEVELOPMENT PRIOR TO INSTALLATION. REQUIRED LANDSCAPING SHALL NOT BE PLANTED IN THE NCDOT RIGHT-OF-WAY. EX. STORAGE x I EX. STORAGE BUILDING ox w I BUILDING I EX. STORAGE I I N F II - I - - -BUILDING J I EX. STORMWATER / Y POND I MCLEOD FOUNDATION INC I ( I ti y o w ti JI On a N/F / i PIN: 892317019099 II / CARPET & APPLIANCE PLAZA INC. _ N F 1 w / II CURRENT USEEDFAMIGLBY DOLLAR STORE D.B. 846, PG. 327� w PIN: 892317017018 KITTY HANK ASSOCIATES LLC � V % C/O WHEELER INT INC - ZONED: 1-1 PIN: 892317003542 I• CURRENT USE: STORAGE FACILITY = Cmp II III D.B. 1038, PG. 24 EX. 15" RCP ------- -- y X. 18 5 O6 E - - - - - - - - - - - - - - - - J n INV = 3.56 - - ---------- ZONED: 1-1 / - EX. DI N 0 - --- - N57' 19 28 E 345 89' -7.70 CURRENT USE: FRISKIES PET CARE PRODUCTS _ _ N5T 28"E 213.00 TO EIR - \ 457 SQ. FT CURBED A -- ----- & SCREENED DUMPSTER t 57_25,/ 5 TC -- - �.,_�..„ OUTFLOW STRUCTURE iI ii I }^ IIJi - / OUTFALL TO t� '� I / \ I I I15' X 301 1 DI Ni BE CLEARED OF I GONG. 0 RIM = 8.40 RIM = 6.75 HEAVY VEGETATION EXISTING STORM WATER POND I I JASHPAIJ INV OUT - 4.25 ' \ per• 36 LF 12" CMP ,_ _ (PERM. POOL ELEV. = 3.50) ! EX. WASH-�T �J II \ TEMPORARY BM INV IN = 3.50 I PAD CANOPY t�°ycpty \ b INV OUT = 2.50 + I OVERHANG E VACODUM I ENEV AIL IN 8,90 PVMT) o\ -DRAWDOWN DEVICE - __� -1 I-c--PAD J �I o51 119 LF 18" CMP \ I NVLIN 1= P INV IN = 4.00 J / INV OUT = 4.15 I I �---- 7.25 g5 INV OUT = 3.50 1 ', �� -� I I I \ I I JB N1 R RIM 8.36 EXISTING 9600 SQ. FT. - _ TC INV IN N 4.15 7.90 PVMT ( ) I RETAIL BUILDING -1'• O - - - _ � INV OUT 4.00 10 20 LF 18" CMP ' INV -INV 1595. ® SAS INV IN 5.450 III I I - I fi 4/1 Ililltrilllll iTf iiil! I7 I I LLIN P DTANK OUND I � 32 LF - 18" RCP �7 I I / , t8. 0 PVMT INV. IN - 6.40' 7A I , INV OUT - 6.00' N � 9 MATCH EXIST. I ® pp (^ I 8.30PVMT1 _ -8.0 PVMT I �iI (TYPC) UNITS 8.2U PVMT: 8.50 TO EXISTING w ir---------� I - O I CONTRACTOR SHALL INSTALL EROSION CONTROL I+ -� &00 FwuT _ 60oPVMT DEVICES AND PERFORM CONSTRUCTION I _ I I ACTIVITIES IN ACCORDANCE WITH CONSTRUCTION NOSE DOWN j Z I DETAILS SHOWN ON SHEETS C900-C901 cuRe 1 8 LF - 15" RCP Y n I FROM END oyi f,F INV. IN - MG _ NV. OUT - MG I I I ¢# Q w NOSE DOWN - $30 PVMT 0 1 ql1fiI �I = I 3 1 CURB 1' 9,00 PVMT '^f' n FROM END i I a y I I i I EXISTING 9600 SQ. FT. RETAILBUILDING I ( I Iw INV 6.5 y i I $ ' PVMT NOISE DOWN 8.00 PVMT R FROM_"D� I I' Ell I I AS I � w a yr I 8 LF - 15" RCP I 'I INV. IN - MG INV. OUT - MG I I� NOSE DOWN 1 aJ' till EXISTING I I I HVAC NITS I I I1` CONSOLIDATED DEVELOPMENT D.B. 527, PG. 896 / PIN: 892317101350 ZONED: 1-1 CURRENT USE: VACANT, I + T T 5.70 P EX, 24" RCP /� INV = 3.74 � S55' 20' 41 "W 387.23' EX 3J RCP 890 PV1 - INV = t2.22 �1 - ilMATOF II CURB V p- FROM END (TYP.) I= I 8.65 TO VT $:08 PVM � - 1---------J 8.115 PVMT INV = 7. 0 _ - S55' 20' 41"i W I 8.30 PVMI 30.0T 8.90 PVMT 4 T I 1 SST 19' 28"W 182.95' EX. DI \ RIM = 6.43 INV = 2.39 SVJ_-SV S+/fl IST. MATCH EXIST. ENLARGED DI RIM = 7.50 MATCH EX. INDUSTRIAL PARK DR. (801 RM)JSR-1206 INV = t2.52 CONSOLIDATED DEVELOPMENT --� D.B. 527, PG. 896 PIN: 892317103416 CURRENT USE: ELECTRICC SUPPLIES INC. - -ZONED: - - - - - - - - - -� EX 30" RCP m �I I IIICn ILU I cc Q �I II =- II I �' M II � I Cr LU IJ J_ :n Y LU L1 J 10. SIGNAGE MUST BE APPROVED AND PERMIT ISSUED BY THE CITY OF ELIZABETH CITY DEPARTMENT OF PLANNING & COMMUNITY DEVELOPMENT PRIOR TO INSTALLATION. 11. ALL UTILITY CONNECTIONS SHALL CONFORM TO THE CITY OF ELIZABETH CITY STANDARDS AND SHALL BE COORDINATED WITH THE CITY OF ELIZABETH CITY PUBLIC WORKS DEPARTMENT. EXISTING UTILITY CONNECTIONS SHALL BE UTILIZED. 12. CONTRACTOR SHALL INSPECT AND MAINTAIN AS NEEDED ALL EROSION CONTROL DEVICES ON A WEEKLY BASIS AND AFTER EACH MAJOR STORM EVENT. FAILURE TO KEEP EROSION CONTROL DEVICES IN GOOD WORKING ORDER MAY RESULT IN THE ISSUANCE OF A STOP WORK ORDER. 13. ANY FILL BROUGHT ON SITE SHALL BE FROM AN APPROVED SITE/MINE. ANY MATERIAL REMOVED FROM THE SITE SHALL BE DISPOSED OF IN A SINGLE APPROVED LOCATION. 14. DISTURBED AREA WILL NOT EXCEED 0.60 ACRES. 15. OFF -SITE PARKING, LOADING AND UNLOADING IN RIGHT OF WAY IS PROHIBITED. 16. NO EXTERIOR STORAGE CONTAINERS, BUILDINGS, ENCLOSURES, ETC. SHALL BE ERECTED ON THIS SITE WITHOUT PRIOR APPROVAL FROM THE CITY OF ELIZABETH CITY DEPARTMENT OF PLANNING & COMMUNITY DEVELOPMENT. 17. ALL STORAGE BINS, TRASH RECEPTACLES, AND RECYCLE CONTAINERS SHALL BE SCREENED. 18. THE CONTRACTOR SHALL VERIFY THE EXISTENCE, SIZE, DEPTH, MATERIAL, LOCATION, AND CONDITIONS OF ALL UTILITIES (PUBLIC AND PRIVATE) PRIOR TO ANY EXCAVATION OR CONSTRUCTION WORK. THE CONTRACTOR IS REQUIRED TO CONTACT (NC ONE CALL) AT 811 AND ALL POTENTIAL UTILITY OWNERS PRIOR TO EXCAVATION IN ACCORDANCE WITH NORTH CAROLINA LAW GOVERNING SUCH WORK. IF THE CONTRACTOR DETERMINES A CONFLICT EXISTS THAT MAY ADVERSELY AFFECT THE PROPOSED WORK, THE OWNER IS TO BE NOTIFIED PRIOR TO PROCEEDING WITH ANY CONSTRUCTION WORK. LEGEND - J EXISTING ASPHALT PAVEMENT _ - ,-' _: PROPOSED ASPHALT PAVEMENT _ - EXISTING SIDEWALK/CONCRETE PROPOSED CONCRETE/SIDEWALK EXISTING RIPRAP PROPOSED RIPRAP PROPERTY LINE - - PROPERTY LINE EXTENSION 1111111111111111111111111111111111 LIMITS OF DISTURBANCE DRAINAGE AREA - - FLOODZONE BOUNDARY _ = EXISTING STORM CULVERT PROPOSED STORM CULVERT --CHE-SHE EXISTING OVERHEAD ELECTRIC -GAS-GAS EXISTING GAS LINE EXISTING FENCE --- ----- -- - --------- EXISTING TOP OF BANK ---- --- - ---- EXISTING TOE OF BANK - EXISTING DITCH/SWALE EXISTING POND PERMANENT POOL EXISTING LANDSCAPED/MULCHED AREA TEMPORARY BENCHMARK ZX EXISTING FIRE HYDRANT D4 EXISTING WATER VALVE D4 EXISTING WATER BLOWOFF w EXISTING YARD HYDRANT D4 EXISTING GAS VALVE ® EXISTING SEWER MANHOLE EXISTING UTILITY POLE 1' EXISTING POLE LIGHT EXISTING DROP INLET EXISTING CURB INLET EXISTING JUNCTION BOX EXISTING DRAINAGE FLOW DIRECTION SHEET FLOW DIRECTION PROPOSED SPOT GRADE • EXISTING BOLLARD EXISTING SHRUB EXISTING MAPLE EXISTING CREPE MYRTLE EXISTING LACEBARK ELM !_•- BLOCK AND GRAVEL INLET PROTECTION C GRAVEL CONSTRUCTION ENTRANCE CHECK DAM GRAPHIC SCALE 30 0 5 ( IN FEET ) 1 inch = 30 ft. 120 Z Cm ~bu �= yye 0raft y0 IEEE42� CD �N \~ rC14 ,..Cm Wei O N ti Q > D W CLW ° Y Z O Of�z Q Q W fn Q O -i X LU W I1� LL �- O O LL J C, U Z OYom O z � 13f N_ Q A J W LU U Q Z 0 O U W z 0 ' _" W Z<Z WO Z) F- Know wnat°s below. LU QQa W U Call before you dig. U) U) 4" 2" RAD 6. 18" D000000c °0o0°ooc 6"� FINISHED PLACE A TOOLED CONTROL JOINT 1" DEEP WITH 1/8" RADII IN THE SIDEWALK AT t5' INTERVALS. INTERVALS SHALL BE ADJUSTED AS NECESSARY SUCH THAT NO SECTION IS MORE THAN 6' OR LESS THAN 4'. A 1/2" EXPANSION JOINT WILL BE REQUIRED AT 30' INTERVALS AND WHERE THE SIDEWALK JOINS ANY RIGID STRUCTURE, INCLUDING BUILDINGS, SIDEWALKS, STEPS, ETC. SEE PAVEMENT o O O o SECTION DETAIL 000-0-0- CURB DETAIL NTS FINAL BACKFILL �._. COMPACT TO 95% - -. SLOPE SIDES AS NECESSARY STANDARD PROCTOR __ FOR CONSTRUCTION (FOR TRENCHES NOT - - UNDER CURB OR PAVEMENT, BACKFILL USING ON -SITE SUITABLE SOILS. FOR TRENCHES UNDER CURB OR PAVED AREAS, BACKFILL - -- - -- USING ONLY - - APPROVED OFF -SITE SELECT BORROW.) OUTSIDE DIAM. OF PIPE 6" 1, 6" TYPICAL STORMWATER PIPE TRENCH NTS NOTE IF SHRUBS AND TREES ARE TO BE COLLECTIVELY LOCATED WITHIN A LANDSCAPING BED, OR IN A CONTINUOUS LAYOUT, WITH SPACING LESS THAN OR EQUAL TO 6' O.C., MULCH SHALL COVER THE ENTIRETY OF THE LANDSCAPING BED OR CONTINUOUS LAYOUT ROOT CROWN TO BE AT FINISH GRADE OR FINISH GRADE 1-2" ABOVE GRADE � 2X WIDTH OF ROOTBALL REMOVE BURLAP FROM TOP THIRD OF ROOTBALL 3" SETTLED LAYER OF MULCH (1-2" ABOVE ROOTBALL) TILLED OR BROKEN UP SOIL (MIN. 12" DEEP) SHRUB PLANTING DETAIL NTS STANDARD HANDICAPPED PARKING SIGN(TYPICAL) TO BE INSTALLED AT REQUIRED HEIGHT AND DIMENSIONAL RELATIONSHIP TO PARKING STALL. HANDICAPPED PARKING STALL —FACE OF 6" CURB AS DIM'D. SITE ON PARKING STALL PAVEMENT MARKINGS (TYP.) — 10.0 FT. WHEELCHAIR ACCESS AISLE/RAMP 0' 1 10 PLAN VIEW OF PARKING STALL(S) - SEE SITE PLAN FOR SITE SPECIFIC DIMENSIONS VAN ACCESSIBLE RESERVED PARKING EDGE OF SIGN MAXIMUM PENALTY $250 125 o-37.6 CLEARANCE: 60" OUTSIDE OF PEDESTRIAN AREAS 84" WITHIN PEDESTRIAN AREAS GRADE A.D.A. STANDARD HANDICAPPED PARKING SIGN (W/ STANDARD HANDICAPPED SYMBOL) VAN ACCESSIBLE HANDICAPPED PARKING, WALKWAY & RELATED DETAILS NTS �2" TYPE SF 9.5A ASPHALT MIX ] 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00000 0 0 0 0( ] o 0 0 0 0 0 0 0 0 0 0 0 0 00000000000 0 0< ] 0 0 0 0 0 0 0 0 0 0 0 0 O� 6" ABC STONE ]00000000000000000( 0000000000000000000000 ] 0 0 00000 0 0 0 0 0 0 0 0 0 0 0 0 0 0( ] o 0 000000000000000 0 0 . 12" OFFSITE SELECT BORROW (AS NECESSARY) COMPACTED SUBGRADE 100% OF ASTM D698 LIGHT DUTY ASPHALT PAVEMENT NTS LEADER SHOULD NOT BE CUT OR DAMAGED PRUNE AS PER HORTICULTURAL PRACTICES PREPARED PLANTING SOIL WOOD STAKE ORIGINAL GRADE —� TAMPED SETTING BED NOTE IF SHRUBS AND TREES ARE TO BE COLLECTIVELY LOCATED WITHIN A LANDSCAPING BED, OR IN A CONTINUOUS LAYOUT, WITH SPACING LESS THAN OR EQUAL TO 6' O.C., MULCH SHALL COVER THE ENTIRETY OF THE LANDSCAPING BED OR CONTINUOUS LAYOUT TWO-PLY REINFORCED --� RUBBER HOSE WITH CABLE OR TURN DOWN GALVANIZED WIRE TOP 1/3 OF AT 12C INTERVALS BURLAP 3" MULCH LAYER 6' DIAMETER / EARTH SAUCER TREE PLANTING DETAIL NTS CENTER LINE OFFSET DETAIL �6" 10' SKIP LINES WHITE 10' �4 /6 NO PARKING LINE �4 /8 * T 30 LLOW 40 YE PARKING LINE �4"/6"* 2' MINI —SKIP LINES WHITE T WHITE CENTER LINE �4"/8"* 2' ��46"* m YELLOW pff 1'T , STOP OR TRANSVERSE BAR 24" *NOTE: WHERE TWO WIDTHS ARE INDICATED, THE FIRST WIDTH APPLIES FOR A "NORMAL" WIDTH LINE. THE SECOND WIDTH APPLIES FOR A "WIDE" LINE. "WIDE" LINES ARE WHITE REQUIRED WHEN DESIGNATED IN THE PLANS, OR WHEN DIRECTED BY THE ENGINEER. TYPICAL PAVEMENT STRIPING NTS JOINT 1/2"- a A d a' 4 d o tl d d CLOSED CELL POL FOAM EXPANSION JOIN 1/8" RADII d d tl d dd a a d a' 4 d SIDEWALK EXPANSION JOINT NTS PRECAST PARKING BLOCK NTS EDGES SF 9.5A ABC STONE STRAIGHT ARROW 1— 20" 12" 64" 10' 4" 32" RIGHT OR LEFT TURN ARROW �— 76" 36" --{ 8" I r 28" COMBINATION STRAIGHT AND LEFT OR RIGHT TURN ARROW 100" 60"44" 14" 56" 324 24„ I12 12" R=2COMBINATION LEFT AND STRAIGHT AND RIGHT TURN ARROW 12" COMBINATION LEFT AND RIGHT TURN ARROW 32" Z- 4.. 32" 76" GENERAL NOTES -ALL PAVEMENT MARKING SYMBOLS SHALL BE WHITE IN COLOR -PAVEMENT MARKING SYMBOLS SHALL NOT BE LOCATED AS TO ENCROACH INTO INTERSECTION AREAS. -ON PORTLAND CEMENT CONCRETE PAVEMENTS, PAVEMENT MARKING SYMBOLS SHALL NOT BE PLACED ACROSS TRANSVERSE EXPANSION JOINTS UNLESS APPROVED BY THE ENGINEER. TYPICAL PAVEMENT MARKINGS PLACE A TOOLED CONTROL JOINT 1" DEEP WITH 1/8" RADII IN THE SIDEWALK AT t5' INTERVALS. INTERVALS SHALL BE ADJUSTED AS NECESSARY SUCH THAT NO SECTION IS MORE THAN 6' OR LESS THAN 4'. A 1/2" EXPANSION JOINT WILL BE REQUIRED AT 30'INTERVALS AND WHERE THE SIDEWALK JOINS ANY RIGID STRUCTURE, INCLUDING BUILDINGS, SIDEWALKS, STEPS, ETC. 4" THICK 3500 PSI CONCRETE SIDEWALK (WIDTH PER PLANS) SLOPE 1/4" PER FOOT CONCRETE SIDEWALK DETAIL NTS TOP OF CURB WIPE DOWN CURB IN 12" TOP OF CURB ELEVATION INDICATED ON GRADING PLAN a c e aPAVEMENe SURFACES �, a. . d 3"R d _ 1"R TYPICAL CURB WIPE DOWN NTS m rl a an z 0 E c N o 4, 1. V N �rk C O b0 J V W c Z c OH 2 a m N W 'O uYi c = m E W ° a m m N ml C Ln Y Zto O N MO �M c ' c X W ^ " > �JV N 0 ICI L N W 3 m 3 N le Iroco L N z w a y~a I" = WO y 1� I"""N ve e v —sue Q W\ O._ e 0 N W /�' �i Q >/ W A �L 1L OU 0 Y Z Y Q Q W _� W< f-z OJ UQ° X LL O o LL ___I 0 U Z '^ Z Yo in TD + N r- Q A J w r 0 ; r a O W 2=N (A O N u c- — ¢ ~ (q ]YYao vZ m � 3 3 U o u U C, U m L O 0 U) U o_ o 00¢0cncn U) C) ® �L xC) H VJ r Z Know what's below. W W V Call before you dig. 0) 6" X 32" WIRE FENCE CONSTRUCTION 1. CONSTRUCT THE SEDIMENT BARRIER OF STANDARD STRENGTH OR EXTRA STRENGTH SYNTHETIC FILTER FABRICS. 2. ENSURE THAT THE HEIGHT OF THE SEDIMENT FENCE DOES NOT EXCEED 24 FILTER FABRIC INCHES ABOVE THE GROUND SURFACE. (HIGHER FENCES MAY IMPOUND VOLUMES OF WATER SUFFICIENT TO CAUSE FAILURE OF THE STRUCTURE.) BACKFILL TRENCH AND COMPACT 3. CONSTRUCT THE FILTER FABRIC FROM A CONTINUOUS ROLL CUT TO THE LENGTH THOROUGHLY OF THE BARRIER TO AVOID JOINTS. WHEN THE JOINTS ARE NECESSARY, SECURELY FASTEN THE FILTER CLOTH ONLY AT A SUPPORT POST WITH 4 FEET FLOW MINIMUM OVERLAP TO THE NEXT POST. 4. SUPPORT STANDARD STRENGTH FILTER FABRIC BY WIRE MESH FASTENED SECURELY TO THE UPSLOPE SIDE OF THE POSTS. EXTEND THE WIRE MESH SUPPORT TO THE BOTTOM OF THE TRENCH. FASTEN THE WIRE REINFORCEMENT, UPSLOPE THEN THE FABRIC ON THE UPSLOPE SIDE OF THE FENCE POST. WIRE OR PLASTIC ZIP TIES SHOULD HAVE MINIMUM 50 POUND TENSILE STRENGTH. 5. WHEN A WIRE MESH SUPPORT FENCE IS USED, SPACE POSTS A MAXIMUM OF 8 FEET APART. SUPPORT POSTS SHOULD BE DRIVEN SECURELY INTO THE GROUND A MINIMUM OF 24 INCHES. 0 8" MINIMUM I 6. EXTRA STRENGTH FILTER FABRIC PATH 6 FEET POST SPACING DOES NOT REQUIRE WIRE MESH SUPPORT FENCE. SECURELY FASTEN THE FILTER FABRIC DIRECTLY TO POSTS. `MRE OR PLASTIC ZIP TIES SHOULD HAVE MINIMUM 50 POUND TENSILE STRENGTH AND A 6 MONTH UV PROTECTION RATING. 7. EXCAVATE A TRENCH APPROXIMATELY 4 INCHES WIDE AND 8 INCHES DEEP ALONG THE PROPOSED LINE OF POSTS AND UPSLOPE FROM THE BARRIER. 8. PLACE 12 INCHES OF THE FABRIC ALONG THE BOTTOM SIDE OF THE TRENCH. 9. BACKFILL THE TRENCH WITH SOIL PLACED OVER THE FILTER FABRIC AND COMPACT. THOROUGH COMPACTION OF THE BACKFILL IS CRITICAL TO SILT FENCE PERFORMANCE. 10. DO NOT ATTACH FILTER FABRIC TO EXISTING TREES. TYPICAL DITCH OR SWALE 8" BLACK ZIPTIE OR ALUMINUM TIE WITH UV PROTECTION STEEL FENCE POST 5' - 0.85 LB. FT. T-TYPE 4 MINIMUM STEEL POST -\ SILT FENCE DETAIL hTS NTS I ,$ MPX__� 18"-24" HEIGHT NOS b MAA. OIANUAKU DIMNUIK rtLItK hAMKIU WIN WIKt MNUL GEOTEX 2134 OR GEOTEX 102F OR APPROVED EQUAL 6' MAX. EXTRA STRENGTH FILTER FABRIC WITHOUT WIRE FENCE GEOTEX 2134 OR GEOTEX 102F OR APPROVED EQUAL 6" X 32" MARE FENCE I I 18-24 i I i l I I 8" DOWN & 4" FORWARD ALONG `\\ _ THE TRENCH `FILTER FABRIC 6 TOP OF DITCH BANK CLASS B STONE SECTION LAYER OF #5 WASHED STONE 12" THICK Top OF BANK BOTTOM OF DITCH PROFILE I CLASS 8 STONE REMOVE SEDIMENT WHEN IT ACCUMULATES TO 1/3 THE HEIGHT OF THE DAM FILTER DAM IS TO BE IN PLACE UNTIL GRASS IS ESTABLISHED IN BOTTOM OF DITCH SUFFICIENT TO PREVENT EROSION CHECK DAM DETAIL NTS CONSTRUCTION SPECIFICATIONS 1. LAY ONE BLOCK ON EACH SIDE OF THE STRUCTURE ON ITS SIDE IN THE BOTTOM ROW TO ALLOW POOL DRAINAGE. THE BLOCK FOUNDATION SHOULD BE EXCAVATED AT LEAST 2 INCHES BELOW THE CREST OF THE STORM DRAIN. PLACE THE BOTTOM ROW OF BLOCKS AGAINST THE EDGE OF THE STORM DRAIN FOR LATERAL SUPPORT AND TO AVOID WASHOUTS WHEN OVERFLOW OCCURS. IF NEEDED, GIVE LATERAL SUPPORT TO SUBSEQUENT ROWS BY PLACING 2 X 4 WOOD STUDS THROUGH BLOCK OPENINGS. 2. CAREFULLY FIT HARDWARE CLOTH OR COMPARABLE WIRE MESH WITH 1/2-INCH OPENINGS OVER ALL BLOCK OPENINGS TO HOLD GRAVEL IN PLACE. 3. USE CLEAN GRAVEL, 3/4- TO 1/2-INCH IN DIAMETER, PLACED 2 INCHES BELOW THE TOP OF THE BLOCK ON A 2:1 SLOPE OR FLATTER AND SMOOTH IT TO AN EVEN GRADE. NCDOT #57 WASHED STONE IS RECOMMENDED. GRAVEL FILTER - NCDOT �#57 WASHED STONE III —III— I INLET WITH GRATE SECTION VIEW BLOCK AND GRAVEL INLET PROTECTION NTS A. NCDOT CLASS 'A' STONE SHALL BE USED. STONE SHALL BE INSTALLED AT 6" MINIMUM DEPTH. B. PAD SHALL BE MINIMUM OF 50' MIN. IN LENGTH. WITH SHALL BE 12' MINIMUM OR FULL WIDTH OF DRIVEWAY, WHICHEVER IS GREATER. C. TURNING RADIUS SUFFICIENT TO ACCOMMODATE LARGE TRUCKS TO BE PROVIDED. D. ENTRANCE(S) SHALL BE LOCATED TO PROVIDE FOR MAXIMUM UTILITY BY ALL CONSTRUCTION VEHICLES. E. PAD MUST BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR DIRECT FLOW OF MUD ONTO STREETS. PERIODIC TOPDRESSING WITH STONE WILL BE NECESSARY. F. AFTER EACH RAINFALL EVENT, INSPECT AND CLEAN AS NECESSARY. G. ANY MATERIAL WHICH IS TRACKED ONTO ADJACENT ROAD SHALL BE REMOVED IMMEDIATELY. �Py P� P�SO\C`\aG PO A TEMPORARY GRAVEL CONSTRUCTION ENTRANCE NTS THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE REQUIREMENTS OF THE EROSION AND SEDIMENT CONTROL STANDARDS AND SPECIFICATIONS OF THE DEPARTMENT OF ENVIRONMENTAL AND NATURAL RESOURCES. SOIL EROSION AND SEDIMENTATION CONTROL MEASURES SHALL BE PROVIDED ON ALL AREAS OF THE SITE WHICH ARE DISTURBED OR GRADED. PROVIDE A GROUNDCOVER (TEMPORARY OR PERMANENT) ON EXPOSED SLOPES WITHIN 14 CALENDAR DAYS FROM THE LAST LAND -DISTURBING ACTIVITY FOR SLOPES 3:1 OR FLATTER AND LESS THAN 50' IN LENGTH, FOR SLOPES 4:1 OR FLATTER OF ANY LENGTH (EXCEPT FOR PERIMETERS AND HOW ZONES), AND SLOPES NO STEEPER THAN 2:1 AND LESS THAN 10' IN LENGTH. PROVIDE A GROUNDCOVER (TEMPORARY OR PERMANENT) ON EXPOSED SLOPES WITHIN 7 CALENDAR DAYS FOR SLOPES STEEPER THAN 3:1 OR SLOPES 3:1 OR FLATTER GREATER THAN 50' IN LENGTH, FOR HIGH QUALITY WATER (HWQ) ZONES, AND PERIMETER DIKES, SWALES, DITCHES AND SLOPES. THE CONTROL MEASURES SHALL BEGIN PRIOR TO ANY LAND DISTURBING ACTIVITY INCLUDING CLEARING; SHALL CONTINUE DURING CONSTRUCTION AND SHALL CONTINUE WITH THE NECESSARY MAINTENANCE UNTIL THE DISTURBED LAND IS STABILIZED. COMPLIANCE WITH LOCAL AND/OR STATE SOIL EROSION AND SEDIMENTATION CONTROL LAWS SHALL BE THE ENTIRE RESPONSIBILITY OF THE CONTRACTOR. THIS PARAGRAPH IS INTENDED TO SERVE ONLY AS A GUIDE TO THE CONTRACTOR FOR COMPLIANCE WITH SUCH LAWS. ORDERS, RULES AND REGULATIONS CONCERNING EROSION AND SEDIMENTATION CONTROL PROTECTION OF EXISTING STRUCTURES AND FACILITIES FROM SEDIMENTATION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. ITEMS TO BE PROTECTED SHALL INCLUDE, BUT ARE NOT LIMITED TO, CATCH BASINS, NATURAL WATERWAYS, DRAINAGE DITCHES, WALKS, DRIVES, ROADS, LAWNS, AND STREAMS. EROSION CONTROL MEASURES SEEDING MIXTURE RATE (LB/ACRE TALL FESCUE 80 PENSACOLA BAHIAGRASS 50 SERICEA LESPEDEZA 30 KOBE LESPEDEZA 10 SEEDING NOTES 1. FROM SEPT. 1 - MAR. 1, USE UNSCARIFIED SERICEA SEED 2, ON POORLY DRAINED SITES, OMIT SERICEA AND INCREASE KOBE TO 30 LB/ACRE. 3. WHERE A NEAT APPEARANCE IS DESIRED, OMIT SERICEA AND INCREASE KOBE TO 40 LB/ACRE. NURSE PLANTS BETWEEN APRIL 15 AND AUG. 15, ADD 10 LB/ACRE GERMAN MILLET OR 15 LB/ACRE SUDANGRASS. PRIOR TO MAY 1 OR AFTER AUG. 15, ADD 25 LB/ACRE RYE (GRAIN). SEEDING DATES BEST POSSIBLE EARLY SPRING: FEB. 15-MAR. 20 FEB. 15-APR. 30 FALL: SEPT. 1-SEPT. 30 SEPT. 1-OCT. 31 SEEDING SCHEDULE SEEDBED PREPARATION THE CONTRACTOR SHALL CUT AND DISPOSE OF WEEDS OR OTHER UNACCEPTABLE GROWTH ON THE AREAS TO BE SEEDED. UNEVEN OR ROUGH AREAS SHALL BE SHAPED AND SMOOTHED TO PROVIDE FOR EFFECTIVE SEEDING AND EASE OF MOWING. THE SOIL SHALL BE SCARIFIED TO A DEPTH OF NOT LESS THAN 5 INCHES. CLODS SHALL BE BROKEN AND THE TOP 3-4 INCHES OF THE SOIL SHALL BE WORKED INTO A SEEDBED BY THE USE OF PULVERIZERS, DRAGS, OR HARROWS. THE PREPARATION OF SEEDBEDS SHALL NOT BE DONE WHEN THE SOIL IS FROZEN OR EXTREMELY WET. SOIL AMENDMENTS APPLY LIME AND FERTILIZER ACCORDING TO SOIL TESTS, OR APPLY 3,000-5,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE (USE THE LOWER RATE ON SANDY SOILS) AND 1,000 LB/ACRE 10-10-10 FERTILIZER. MULCHING APPLY 4,000 LB/ACRE GRAIN STRAW OR EQUIVALENT COVER OF ANOTHER SUITABLE MULCH. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, ROVING, OR BY CRIMPING WITH A MULCH ANCHORING TOOL. A DISK WITH 3LADES SET NEARLY STRAIGHT CAN BE USED AS A MULCHING TOOL. MAINTENANCE IF GROWTI- IS LESS THAN FULLY ADEQUATE, REFERTILIZE IN THE SECOND YEAR, ACCORDING TO SOIL TESTS OR TOPDRESS WITH 500 LB/ACRE 10-10-10 FERTILIZER. MOW AS NEEDED WHEN SERICEA IS OMITTED FROM THE MIXTURE. RESEED. FERTILIZE, AND MULCH DAMAGED AREAS IMMEDIATELY. SEEDING & MULCHING UStW 1WN06'U Tr 4Qi��� fYl.�if %• z co CD o P1111 C/�Goa _= rm WO CA mac_ — W �N �' ��o ..dN W o C. O C N W I— >/ Z) W A L 0� UU 0 Y ZzYQQ W U) < O _j U < 0 0° X a W W I L ILL O5 U) LL J Uz OYom (D z 1 N_ T- Q 0- J w Z O H a 0 1n W 0 L Z ® O W .J 0 O w v) Oz~ ¢ LU Z� F- w r, U Know what's below. = W 0 LU Call before you dig. 1n 1n