Loading...
HomeMy WebLinkAboutSW7090301_APPROVED PLANS_20090316STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW DOC TYPE ❑ CURRENT PERMIT APPROVED PLANS HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE- YYYYMMDD Y LEGEND SOURCE OF TITLE ELIZABETH CITY MUNICIPAL AIRPORT U.SC.G.A.S. SITE VICINITY MAP NTS NOTE: ALL ELEVATION DATA SHOWN ON THIS DRAWING IS RELATIVE TO AND PREDICATED ON A ELEVATION OF 7.40 FEET (N.A.V.D. 88) OF NORTH CAROLINA GEODETIC MONUMENT "COAST'. X\\\ RAY FR. 0 ECM = EXISTING FOUND CONCRETE MONUMENT O EIR = EXISTING FOUND IRON REBAR O EIP = EXISTING FOUND IRON PIPE O NIR = NEW SET IRON REBAR Oo POINT = NO MONUMENTATION FOUND OR SET O SPK = NEW SET P.K. NAIL O EPK = EXISTING FOUND P.K. NAIL ----RIGHT OF WAY LINE -----TOP OF DITCH BANK � WOODLINE -x-x-x-FENCELINE TREE - -- - -DITCH CENTERUNE RAILROAD TRACK - - - - - - 404 WET LAND LINE - -- OHE= OVERHEAD ELECTRICAL SERVICE EOP=EDGE OF PAVEMENT SURVEYED OUTSIDE BOUNDARY '-O_a POWER POLE ® WM=WATER METER (S)SANITARY MANHOLE WV N WATER VALVE O TP = TELEPHONE PEDESTAL *SECURITY LIGHT ON POLE El EB=ELECTRICAL BOX El EO=ELECTRICAL OUTLET OSCO=SANITARY CLEAN OUT ®DRAINAGE MAN HOLE D.B. 317, PG. 164 D.B. 729, PG. 789 D.B. 317, PG, 326 D.B. 317, PG. 164 D.B. 593, PG. 4-67 P.K. NAIL SET AT APPARENT CENTERUN INTERSECTION OF FOLLEY ROAD (N.C.S.R. 1130) AND WEEKSVILLE ROAD (N.C. HWY. NO. 34). x 0,90 REFERENCES D.B. 366, PG. 427 / 1 D.B. 366, PG. 118 3 1 A NEW IRON REBAR SET 1 IN DITCH CENTERUNE / 1W RAYMOND A. NEWBERN AND WIFE PRANCES N D.B. 366,, PG.G. 427427 1 Ct o 0 ;1 o 5.56 1 1 0 1 1 / 4y LA 1 I �{ 1.47 ' 4.Y iA9 x FOZ I I 1 wMAT� Y _ : NJ I II I 404 86.8 4z94fi - - � \\\ \\ ////i///' •/404/p\1'r� 1 i I II \ \ \ NEW IRON REBAR SET .• Pod Cemetery Lot I 1 I \\ \ IN DITCH CEN RLIIN /' I / °� 4°4 • x i.96 N �p�l.11 I 1 I I \ \\ \ \ / / • Y O /x 675 8 1 I I I /// N� 148.0 I 1 \ \ / \"" poi 5 i3 268%69 . I 1 5 .51 \ \ / // x267 x7.51 x7�A >�757 \\\ NEW 5 FOOT TALL IRON PIPE .��t / I 1 1 4.)7 x 660 x t5° AINN 1 1 7!H \ \ \ \ N78'15'00"E /� Vt6� 1 # 7.I9 l x 755 1 I I \ \\ \ POI N /� Y� O4 x 4A5 p��•,'i x ki x 0x7..% 1 1 I 1 \ \ 049 00 �plµ� \ O x 470 / x 575 LAWN) 3 1 I 1 \ \' x 645 CARER .0 o 1 1 1 \ \ x 5A5 riI 1 1 I I \ \ / x 4�.4 i {9 \ \ � x 569 x 565 k % x 765 \ In \\ \\ 46./ f,OrpxJflr / z 65°5A5 x 7XI721 \\ OG \\\ \\O jN� / x bi0 x bit \ / x ib4 x 746 x �Bp. \ \\ \\ ice/ x AREA xbx162 x6.a •T x i'� x7w \ xs29 3.514 ACRES± .M.D. TO \ g L x 604 ��ll BY D.M.D. \ \ \% x 7.74 \N_ x 7.5I I x 6w x 760 x 7.90 x 74 7.54I x 681 N M J \\ \ x 6.55 x 608 iVl 1 x 7.w a x 6D5 N I 1 \ \ \ x 669 x 7P x 761 $ I I \ \ W \ \ x 000 x 706 x 766 F N \ \ .24 x701 x759 x7A7 xTO x 7. \\ x ,46 x 7.--- -IRON PIPE xi4o l--- \ 72 76' 77A x 600 \ x 666 x 1.16 -- x 6 165 I I NEW 11R BAR SET \ x 80GRAVEL 1 12' IN DIT ¢ONCENTERLINE \ z 757 x 7A7 - - - DRIVEWAY - - 03* " x 600. 2 0m X FOUND IR N p� f x 6.75 x 755 x 151 Y -'A�x. R5�fi11� x 606 x 729 K \ 433.02' 7.51 NOTE K FENCE IS 6' HIGH x BMX D.1;EI \ FOUND PINCH \ \\ 5x 665 7I" - CHAIN LINK \ PIPE BEN 51 x 5� 1� .:....... Imo' I 1 N21.55 00"W * :::x 77-9:1 x 66i x 7O5 x 70 x 7.% �I 65 8.91' �� , S N`:CONC.:;;I s2 I I POINT ,. .... ASPHALT N / WASH PAD ... \ NOTE ^'• p i SHOP T; x !I , x Im FENCE IS 6' HI C. 091 ASPHALT CH/ 40yNK I PADS x 70 I to x 559 g x 705 x 7" AREA x 767 NOTE \ ���• o� t ASPHAL� FU a STORAGE COVERS. 3.600 ACRESf GATE IS 2 PIECE \ \w 5.56 AGE b.% x 7.56 SLIDING TYPE �• ARE-rx2' t BY D.M.D. x 769 : x 7. f 4JND-I.r DIA l xi60 is¢i::::::::: ...._ xTM I 7.95 6.16 I \ \ bbl ;:.;:::.;.::: --\ CITY BEVERAGE COMPANY. INC DI i D.B. 317. PG. 164 ,N A?i ASPHALT x �762 7 RIM EL-7.72 \ x p..-r: \ G ��i \\ POINT 'f p.o".d•P►k::::::::::'\N..p.O::::::::. 7A � 7 I INV EL-4.64 1 \ 0 1.2A q.i..::: .. 7 x 7. 55 I ��qq'' 'I • :iiii'y'y 75�Z5i7%::i?'r'r 75 Ai 765 1 p► ` ... ::::::......::i:iiili..... 5:[i:. 7.71 x 779 P \ i;::... .. ..... ... y ! PINE TREE ;:`: :::::::x 7.9°x 5.76 .Nx 7"W:it�Ia2. # s. 18'RCP 1 I INV-4.88 \ \ d \ \ tNe\�p►p x -065\\p if 6NOTE, 4 C&MH x 6NJ AfW K• HIGH ro II }I 1I kII 7 tillREA I 7 II BAI *6 FLAG POLE e7% x IIII I I $ \ \ \ METAL SIDING 651 �4�1 I I w 1 BUI IN •�• �, I I I I I OTE I \ C � IGH \ \ I I I I I 25.0 53.8 1 1 I "M6 626 I 1 x 1.74 . I I x 7.56I 1 I I III n a \ \\ ,, \boo. \ e�0 �• to I I 1 T'F�T I METAL SHED ATTACHED \ \ \ bZ \f 5 \\ \ • x 76i 7.76 I I I I OUTSIDE OF BUILDING. \ \ \ x160 I I I $ I x 6.95DI \ PO T RIM EL-7.87 NOTE: o I I I 15"CMP } 11 I NOTE \ \\ \ \ `959 INV EL-8.08 k n ' t INV-5.10 3 AIR CONDITIONING UNITS ON CONCRETE \ \ \\ , .:.::::::::..... CHAIN 16 R19Hu1 o<I i PAD. EACH UNIT IS 3.8x 11.55. SPACING \ \ \ \ \ \ 6 x 767 CHAIN LINK q BETWEEN UNITS IS 5. \ \ \ \ �'"� \ \ v: :::C�y ASPHALT I C x 1 I 06 3 I x 604 G -*P- GATE IS 2 PIECE ' � SLIDING tap 5 6. \ \ x 5.76x 75 ASPHALTC.R"NG �.slF.k}E;::.::.::.;.\ I NOTE: C \ \ \ \ f xavt6" \,O� x ¢::::::::>::��?:?::?I1.95 1 CODE KEY BOX TOI \ \ \ \ \ \ NOTE F� .... .1:;):j::::::CONTROL. GATE \ \\ x N g 6' HIGH ............... 605 . \\ k _ + ��CFI LINK \ \ \ k 76 \ \ 565 ............. :i:.:y1 \\�7 POINNOT"\\:� NOT NOTE: \1(i. 25.0 ` \ 0.40' WIDE METAL \pint NG RAILROAD TRACK IS IN PLACE AS SHOWN, BUT APPEARS TO HAVE BEEN ABANDONED. \ \\ 6 \\ \ SLOT DRAIN. \\ \ \ \ F= \ IM EL-5.1 ° UWALr x 72\ \ \ ,k 57 9 i\ A \ \ \ p 0 7 \ p % \ \\ A: �ETAL SIDING /� x - N P COUNTY / I NG lo NORTH CAROLINA, OTANK ASQU \ \ \ 4f•. •rn. I, RENEW OFFICER OF PASOUOTANK COUNTY \ \ DIN1\ CERTIFY THAT THE MAP OR PLAT TO WHICH THIS CERTIFICATION IS AFFIXED MEETS ALL STATUTORY REQUIREMENTS FOR RECORDING. \ \ . \ RENEW OFFICER x7A6 a0 m I, KENNETH M. SEYMOUR, CERTIFY THAT THIS PLAT WAS DRAWN BY ME FROM AN \ \ .o g0• (�-- ACTUAL FIELD LAND SURVEY MADE UNDER MY SUPERVISION; THAT THE BOUNDARIES T NOT SURVEYED ARE CLEARLY SHOWN AS DASHED LINES DRAWN FROM INFORMATION FOUND LISTED UNDER REFERENCES;THAT THE DEED DESCRIPTION FOR THE PARENT \\\\\\\ \ ►�51�1� BUILDING ENCROACHES ONTO\ 4,2 �G PROPERTY IS LISTED UNDER SOURCE OF TITLE,: THAT THE RATIO OF PRECISION AS RAILROAD RIGHT OF WAY AS CALCULATED IS 1:10.000+ • THAT ALL AREAS ARE CALCULATED BY D.M.D.:THAT THIS \\\\\ \ 25 MAP WAS PREPARED IN ACCORDANCE WITH BOARD RULES OF PRACTICE, WITNESS MY SHOWN AND DIMENSIONED. \ \; \ 25.b* 76i2.5 ORIGINAL SIGNATURE. REG. NUMBER AND SEAL THIS 0AY OF 2006, S2B Z a^^d 1 € N {. L 3T29 F DATE, _ zJ i 3 d t d pp x 746 \ 9 9 \ \\\ \\ 7.5715.0 �F 1, KENNETH M. SEYMOUR. PLS-3129, CERTIFY, \\�\ A. THAT THIS IS OF A SURVEY THAT CREATES A SUBDIVISION OF LAND WITHIN THE AREA OF A COUNTY OR MUNICIPALITY THAT HAS AN ORDINANCE THAT REGULATES PARCELS OF LAND. GRAPHIC SCALE i 40 0 20 40 eo ISO B. THAT THIS PLAT IS OF A SURVEY THAT IS LOCATED IN SUCH PORTION OF A COUNTY OR MUNICIPALITY THAT IS UNREGULATED AS TO AN ORDINANCE THAT REGULATES PARCELS OF LAND. x 1.54 ( IN FEET ) C. THAT THIS PLAT IS OF AN EXISTING PARCEL(S) OF LAND. I inch = 40 ft. OD. THAT THIS PLAT IS OF ANOTHER CATEGORY, SUCH AS THE RECOMBINATION OF EXISTING PARCELS, A COURT ORDERED SURVEY OR OTHER EXEMPTION TO THE DEFINITION OF SUBDIVISION. E. THAT THE INFORMATION AVAILABLE TO THIS SURVEYOR IS SUCH THAT AM UNABLE TO MAKE A DETERMINATION TO THE BEST OF MY PROFESSIONAL ABILITY AS TO THE PROVISIONS CONTAINED IN (A) THROUGH (D) ABOVE. A 7k-cr� �r 1 50CMP I I I .J7 I IINV-5.13 x 7t{ I I1 1$ I I .4G4 I I I I W I I I I II III I 1 x6.11I 7.95I NOTE. DRAIIMAGE MAN DLES 1OHE- I RIM EL-8.45 ...IVY a.Ir-!270 , GLE WIRE1 I I I W II I I NV EL-274AI/ n 11l I I x 7.116'r 7. 797 II I 1 WV POINT 7 + I7'�15 W I ENT FOR ACCESS EA ASQUOTANK COUN WATER SYSTEM I I D.B. 593, 466 I I IG. I Wlil 1 I 15"ROP I i I : INV-5.20 1 I ®MIT \X 721. 1 NOTE WIDER LINE IS METAL GUARD RAIL 15'RCP TPV7 4 INV6-5.32 754 615 �k1 SA4 x 765 SOLUTIONS FROM THE GROUND UP 150 US Hwy 158 E. PO Box 339 Camden, NC 27921 (252)338-2913 (252) 338-5552 fax www.hymanrobey.com -VA BOUNDARY BOUNDARY AND TOPOGRAPHIC SURVEY FOR CITY BEVERAGE COMPANY NIXONTON TOWNSHIP PASQUOTANK COUNTY NORTH CAROLINA KEY PLAN: Project #: 080108 Drawing #: 080108-TP1 Drawn: KMS Checked: KMS Approved: KMS Date: 05/01 /2008 Sheet #: 1 OF 2 Scale: 1 "= 40' REVISIONS: NUM. DATE DESCRIPTION SHEET TITLE: SHEET NUMBER: 1 L NARRAT ME - THIS PROJECT CONSISTS OF THE DEVELOPMENT OF A PARCEL IN PASQUOTANK COUNTY, NORTH CAROLINA. THE DEVELOPER INTENDS TO DEMOLISH PORTIONS OF EXISTING STRUCTURES AND CONSTRUCT NEW EXPANSIONS OF EXISTING STRUCTURES. THE PARCEL IS ADJOINED ON THE EAST SIDE BY WEEKSVILLE ROAD AND THE WEST SIDE BY SOUTHERN RAILROAD EASEMENT. THE SITE IS RELATIVELY LEVEL AND HAS EXISTING IMPROVEMENTS. APPROXIMATELY 3.7 ACRES ARE TO BE DISTURBED. CONSTRUCTION IS SCHEDULED TO BEGIN IN THE SPRING OF 2009. THE SITE IS ACCESSED BY EXISTING PAVED DRIVEWAYS. AN EXISTING SOIL DRIVEWAY WILL BE IMPROVED AND USED AS THE CONSTRUCTION ENTRANCE. SILT FENCES ARE PROPOSED TO CONTAIN ANY MOVEMENT OF SOIL DURING CONSTRUCTION. THIS PLAN ILLUSTRATES SILT FENCES LOCATION. SHOULD THE NEED FOR ADDITIONAL FENCING BE DETERMINED DURING CONSTRUCTION, IT WILL BE INSTALLED AS DIRECTED BY THE ENGINEER OR NC DEHNR AGENT. L SOUS SOIL TYPES AS MAPPED IN THE SOIL SURVEY OF PASQUOTANK COUNTY: PeA - PERQUIMANS SILT LOAM ChA - CHAPANOKE SILT LOAM TeA - TETOTUM FINE SANDY LOAM CwA - CHOWAN SILT LOAM 1. CONSTRUCTION SEQUENCE- OBTAIN PLAN APPROVAL. FLAG OR STAKE WORK LIMITS. CONTACT NC ONE CALL FOR LOCATION OF UNDERGROUND UTILITIES. HOLD PRE -CONSTRUCTION MEETING. INSTALL GRAVEL CONSTRUCTION ENTRANCE AND SILT FENCING. CLEAR LOT OF EXISTING VEGETATION AS SHOWN. GRADE NEW STORMWATER POND AND DRAINAGE FEATURES. (SEE SEDIMENTATION AND EROSION CONTROL NOTES 9 & 10). PLACE, COMPACT AND TEST ALL FILL MATERIAL PURSUANT TO GRADING PLAN. SEED, FERTILIZE AND WATER DISTURBED AREAS TO STABILIZE WITH TEMPORARY SEEDING. INSTALL AND TEST ALL PROPOSED UNDERGROUND UTILITIES. COMMENCE CONSTRUCTION OF IMPROVEMENTS. UPON COMPLETION OF ALL SITE WORK, SEED, FERTILIZE AND WATER DISTURBED AREA TO STABILIZE WITH PERMANENT VEGETATION. IV. SEDK04TATM AND EROSION CONTROL NOTES 1. ALL CONSTRUCTION TRAFFIC SHALL UTILIZE THE CONSTRUCTION ENTRANCE AS DESIGNATED ON THE PLAN. 2. ALL REMOVAL AND DISPOSAL OF SITE DEBRIS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE REMOVED BY THE CONTRACTOR TO AN OFF -SITE LOCATION. 3. AREAS WHICH HAVE BEEN DESIGNATED IN THE PLANS TO REMAIN UNDISTURBED SHALL BE IDENTIFIED PRIOR TO CLEARING. IN ADDITION TO SECTIONS SHOWN WHERE ALL VEGETATION IS TO REMAIN, ADDITIONAL SPECIMEN TREES MAY BE SPECIFIED AND FLAGGED TO REMAIN. 4. NO BURNING IS PERMITTED ON SITE UNLESS AUTHORIZED BY THE FIRE MARSHALL. 5. NO BORROW PERMITTED FROM THE SITE EXCEPT AS NECESSARY FOR GRADING OPERATIONS. 6. AREAS WHICH ARE TO BE FILLED SHALL BE RAISED IN COMPACTED SEQUENTIAL LIFTS. FILL MATERIAL SHALL BE CLEAN, WELL GRADED SAND IN ACCORDANCE WITH THE GEOTECHNICAL RECOMMENDATIONS. 7. EXISTING TOPOGRAPHY INFORMATION BASED ON THE SURVEY INFORMATION PROVIDED BY HYMAN AND ROBEY IN A SURVEY DATED MAY 1, 2008 AND HAS NOT BEEN FIELD VERIFIED. 8. PROVIDE A GROUNDCOVER (TEMPORARY OR PERMANENT) ON EXPOSED SLOPES WTTHING 21 CALENDAR DAYS FOLLOWING COMPLETION OF ANY PHASE OF GRADING; AND A PERMANENT GROUNDCOVER FOR ALL DISTURBED AREAS WITHIN 15 WORKING DAYS OR 90 CALENDAR DAYS (WHICHEVER IS SHORTER) FOLLOWING COMPLETION OF CONSTRUCTION OR DEVELOPMENT. 9. THE EMERGENCY WEIR SHALL BE INSTALLED PRIOR TO CONVEYING DRAINAGE TO POND. 10. PRIOR TO PLACEMENT OF THE STORMWATER CONTROL STRUCTURE, THE CONTRACTOR SHALL GRADE AND ESTABLISH SOD WITHIN THE LEVEL SPREADER. UPON SETTING THE STRUCTURE, A TEMPORARY PLUG SHALL BE PROVIDED ON THE OUTLET PIPE (WITHIN THE STRUCTURE) AND SHALL REMAIN UNTIL SITE STABILIZATION IS ACHIEVED. REMOVE SILT FENCES ONCE PERMANENT VEGETATION IS ESTABLISHED. GFIAPHIC SCALE 40 0 20 40 80 V. DEMOUTION NOTES 1. CONSTRUCTION FENCING SHALL BE PLACED IN ACCORDANCE WITH NC STATE BUILDING CODE. 2, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER DISPOSAL OF DEMOLITION MATERIALS TO AN OFF SITE LOCATION PROVIDED BY THE CONTRACTOR, 3. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO CAREFULLY REMOVE ALL ITEMS SHOWN TO BE RELOCATED. PRIOR TO REMOVAL, ANY CONDITIONS THAT PREVENT SUCH REMOVAL OR EXISTING DAMAGE TO THE ITEMS SHALL BE REPORTED TO THE OWNER IMMEDIATELY. CONTRACTOR WILL BE RESPONSIBLE FOR ITEMS DAMAGED DURING THE PROJECT. 4, SPECIAL CARE SHALL BE TAKEN DURING DEMOLITION ACTIVITIES IN ORDER TO PRESERVE EXISTING VEGETATION SPECIFICALLY NOTED TO REMAIN. ANY SUCH VEGETATION DAMAGED BY THE CONTRACTOR SHALL BE REPLACED BY THE CONTRACTOR AT THEIR EXPENSE. \ \ \ \ m \ I \ I 'EXISTING PAVEMENT I \ It U \ \ �� \ x I � I RF/•TRH REMOVE WASH SHOP, p' CONCRETE PADS AND II {�_ \ € 10 FUEL STORAGE AREA / x \ x x I `�� \ \V � �\ "r� w� \\ � \\ � // RE✓iOCATE FENCE �jc N/1= Y ' � r RAYMONP A. NEWBERN AND WIPE \ \ v \a x I _� �Db�366 P6 �\ \ atEAINGOODREMAIN �iR `\ L / ZONED R-0 x. 1 L RESIPEWIAL \ \ $ y / D.B. 336, P0. 118 \ PLACE SILT FENCE \Q \ BEHIND NEW FENCE LINE IPF pwim .n AIDFNT) b S RON PIPE / !� SET M DffGH 0. / / 160 8.91, SILT OF E LINE E%ISTNG BUILDING AND e16 i'{ E%ISNNG PAVEMENT AR 60Ifff16NN6 UNITS ON LLNGREM PAD y (5045B' EAA LNI1) WrAL SHED ATTAgTP TO arsm M1LPW REMOVE PORTION OF EXISTING BUILDING ,V MW CHAIN LINK 184.E SEPTIC SY3Tm Aa4A1DoAamyT MOTES 1. DISCONNECT ALL EXISTING POWER TO THE SYSTEM AT THE SOURCE. COORDINATE POTENTIAL RE -USE OF EXISTING POWER LINES WITH ELECTRICAL PLANS AND SPECIFICATIONS. 2. OBTAIN AN APPROVED HAULER PUMP TO REMOVE ANY REMAINING LIQUID, SLUDGE, AND SCUM FROM TANKS TO BE ABANDONED/REMOVED. 3. REMOVE TANKS AND PROPERLY DISPOSE OF REMAINS AT AN AUTHORIZED LANDFILL. IN THE EVENT EXISTING TANK LOCATION DOES NOT CONFLICT WITH NEW TANK LOCATIONS, TANKS SHOWN TO BE ABANDONED MAY BE CRUSHED IN PLACE AND BACKFILLED WITH CLEAN FILL FROM AN APPROVED SOURCE. 4. REMOVE EXISTING DRAINLINES WITHIN DRAINFIELDS SHOWN TO BE REMOVED. 5. BACKFILLED AREAS SHALL BE COMPACTED TO A MINIMUM OF 95% DENSITY. MORE STRINGENT COMPACTION REQUIREMENTS MAY APPLY WITHIN THE GEOTECHNICAL REPORT. 6. UPON COMPLETION OF REMOVAL, BACKFILL, AND COMPACTION, ALL DISTURBED SUFACES SHALL BE COATED WITH HYDRATED LIME (IF EXPOSED TO EFFLUENT) AND A VEGETATIVE COVER SHALL BE ESTABLISHED. A�i i N29'35'%�j�' 100 •\ ". .; ,,vim �/�//� i i / /•ii // / _ 4 , x NOTE: / / n APPLICABLE AT ALL POINTS OF INGRESS & 2"-3" COURSE 6" MIN AGGREGATE 4 EGRESS UNTIL SITE IS STABILIZED, s x FREQUENT CHECKS OF THE DEVICE AND x TIMELY MAINTENANCE MUST BE PROVIDED. MOTEE& 50' 1. WASHED STONE (#4 STONE OR 2" TO 3" AGGREGATE). PAD TO BE 501 X 20'W X 6"D AT A MINIMUM. 2. TURNING RADIUS SUFFICIENT TO ACCOMMODATE LARGE > TRUCKS IS TO BE PROVIDED. 20' 3. ENTRANCE(S) SHOULD BE LOCATED TO PROVIDE FOR MAXIMUM UTILITY BY ALL CONSTRUCTION VEHICLES. 4. MUST BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR DIRECT FLOW OF MUD ONTO STREETS. PERIODIC TOP DRESSING WITH STONE SHALL BE NECESSARY. �`o %j - / i/ N CITY MVERA6E COMPANY ZONED A-1 A6RI6(LTLRAL LOADING RAMP x ❑ EXISTING WATER METER D4 EXISTING WATER VALVE --- EXISTING WATERLINE EXISTING DITCH/DTICHBANK - - EXISTING RAILROAD - - RIGHT OF WAY PROPERTY LINE -X-X- EXISTING CHAINUNK FENCE 0---- il ----0- EXISTING GUARD RAIL ••.Y�y...,� - EXISTING TREEUNE EXISTING PAVEMENT EXISTING CONCRETE E_ ❑ (STING DRAINAGE PATTERN ",.- ` -••«�- ,"`•••••. AREA OF DISTURBANCE SF PROPOSED SILT FENCE NOTES: d 1. 6' POST SPACING FOR Fe % NON -WIRE REINFORCED T FENCE. 8' POST SPACING PERMITTED IF FENCE CONTAINS REINFORCING WIRE. 2. 4' MINIMUM OVERLAP REQUIRED (ATTACHED AT N POSTS) WHEN JOINING SECTIONS OF SILT FENCE. 3. SILT FENCE SHALL BE X0\\j/ \T \//\ j ATTACHED TO STEEL POSTS / \\\\ USING A MINIMUM \3 \ WIRE OR PLASTIC TIES. STEEL POST COMPACTED FILL WIRE REINFORCED SYNTHETIC FIBRE JUTE MESH FILTER FABRIC EXTENSION OF FILTER FABRIC INTO THE TRENCH -\ DIRECTION OF FLOW - I \ CC14 9LT EE NICE QE%AL NTS API&1-MAY 0PL WQi3 FSEEDKi SPECIES RATE K-31 FESCUE 3 LB/1000 SF COMMON BERMUDAGRASS 1 LB/1000 SF WINTER RYE GRAIN 3 LB/1000 SF MAY 15 - ALY 10 PEWANERT SEED10 SPECIES RATE K-31 FESCUE 3 LB/1000 SF COMMON BERMUDAGRASS 1 LB/1000 SF GERMAN MILLET 3 LB/1000 SF AUL WE-API&tTELVM iYSEED1Ki SPECIES RATE K-31 FESCUE 3 LB/1000 SF WINTER RYE GRAIN 5 LB/1000 SF 80L AMENDME 8 APPLY LIME AND FERTILIZER ACCORDING TO SOIL TESTS, OR APPLY 500 LB PER ACRE OF 10-10-10 FERTILIZER. IIIIIIIIA" USE JUTE, EXCELSIOR MATTING OR OTHER EFFECTIVE CHANNEL LINING MATERIAL TO COVER BOTTOM AND SIDES OF SWALES. ANCHOR MATTING PER MANUFACTURERS RECOMMENDATIONS. HYDROSEEDING IS ALSO AN ACCEPTABLE METHOD OF TEMPORARY STABILIZATION MAllil@MNCE A MINIMUM OF 3 WEEKS IS REQUIRED TO FOR ESTABLISHMENT. INSPECT AND REPAIR MULCH FREQUENTLY. FERTILIZE THE FOLLOWING SPRING WITH 50 LB/ ACRE NITROGEN. p 8 T O rn v m rn m _{Qm�mN�rnii a10 a �m2o Zm�Q °a 10Uu`vi�E m3t��a Ezt v9 '�Ewoa Ezau�a c d r N 0 9aQ�t =2 t a a m a Q W LL LL F O J O !� E. rn Lu o = 0 O m m Y m W o c w � 2 Y w iJi' SCALE: 1 " = 40' c 101 TIT (IN FEET) 1 INCH = 40 FT. BEFORE YOU DIG 1 CALL TOLL FREE 1-800-632-4949 9RTH CAROLINA ONE CALL \ (CONTROLLED \ \ \ \ \ ENVIRONMENT \ \ WAREHOUSE) N/F RAYMOND A NE kl AND WIFE FRNJGEs J PEWPERN \ \\ DIP. ' 6", P6. 427 \ / / / / / / / RESIDENTIAL \ \\ \ \ t/ ^ \\ NEW 6' CHAIN B. 336, PG. 118 \\ \\ \ LINK ,FENCE ..�- / �� / / • I D� IFF (Flw-tnrp / 1 / / AM? NM 000) 40 C �T M DITCH 0. E S} 7 C202 FO1R ADM AAD DEri4L8 / / / N/F CITY DEVERA6E 60WANY ZONED A-1 A6RVAlTUZAL Q9APHIC SCALE 20 40 80 (IN FEET) 1 INCH = 40 FT. 160 I it 1►/film iiy=<<1T/1►010 XIa;W lZ = vi cllcwLLJ �0 �03 0 ofo U o J ai C m p m m rn " m .o m Q n m m N Q m MOb m W ' 'i E Z 0 N m O�i3Uv`„i^E z t o m O U E'c Q a EZa ui �¢ m U 0 va=tt m a m n a r N ¢�waLL t a H0JcT U) Z 0 ?V) W 2M J C�l cr U CC O Zz g z� � _ U m C�WY "HC5 PK NAIL SET W J =:) GNL CALCULATED POINT LL J Q o6v EXISTING SANITARY CLEANOUT LL CL © EXISTING SANITARY MANHOLE 8 EXISTING TELEPHONE PEDESTAL ® EXISTING ELECTRICAL BOX/OUTLET Q L' 1 \♦�J EXISTING SECURITY LIGHT l/c Rc V CL EXISTING UfILffY POLE _ EXISTING GUY WIRE Z EXISTING OVERHEAD ELECTRIC � �r_ EXISTING DROP INLET Z ~ EXISTING STORM PIPE O ® EXISTING DROP INLET ,_ ZE EXISTING STORM PIPE X z EXISTING HYDRANT ❑ W I' I EXISTING WATER METER m x EXISTING WATER VALVE -- - EXISTING WATERLINE to PROPOSED FIRE HYDRANT `,/J N PROPOSED WATER VALVE V U —W PROPOSED WATERLINE ~ W — EXISTING DITCH/DRCH9WK QQ — — — — — N EXISTING RAILROAD RIGHT OF WAY J LL, PROPERTY LINE X X— EXISTING CHAINLINK FENCE X X— PROPOSED CHAINUNK FENCE 1--- 0---- C)- EXISTING GUARD RAIL O EXISTING TREELINE Z 0 \ w m o EXISTING PAVEMENT O N f X m W PROPOSED PAVEMENT LOT C, Tp� EXISTING CONCRETE U Z Y In K> a U PROPOSED CONCRETE wK G In o U w SCALE: 1" = 40' C201 Mal NO. Y u Y xb.»w I ,,�, {,¢' l.. Y �rj - .>. •SiATON ° N \ RELOCA 7.52DRAI %An � A x(,55 ( D PAIR) 't \ `�•. ✓ ;- a °4 k / s w e i ., 6T Furl 0. a �P 6.21 x701 'bg i. x _ a 7.99 .1 's' x7....a 2¢, _ 2 �. \ \ 9 / �i TION tRUC GRAPHIC kALE 1 INCH = 20 FT. \ I x7H �. i • ETAININO WALL. x,y' x b.% ,.:. 1 1 x x a x STORM MANHOLE ^ - - - Wn i RIM 7.05 Ai4 �\ INV -3.34 (NE) _SON �NO ,x7.De x. z x .. x zbb'! a x772 ° < ;. 5.1 x 0.51 i z 661 S_v; CIO H Z Z gcr- o W oZ W oc 0 U r R Y 5 vLLJQ �OCJci Q LQ 0 = 1 Z W Z Z zo c� U 2 ¢m NLLJ \ O a,W Z O f Q `< O O N m Y � W z C W W Z ic toFn 3 w D 0 U ri SCALE: 1 " = 20' C301 ilia. ►.6WfjTK1,.;] SEE ShME-7 V303 rOT1 I10IGa7 AND FE6 \\ \\s �\ fi W/SUMP PUMP i_ i 7gW.�k 7.Y� . BEFORE YOU DIG I CALL TOLL FREE 1-800-632-4949 )RTH CAROLINA ONE CALL RU7.54 . \\ \\ a° 'a INV 4.38 (NE) I II DRAIN RIM 4.8 \ \ RIM 4.80.71 \\ \\ x7 \ \ \ 6IN6(.E STORY / METAL SDINGCfAPHIC SCALE Ww'lNf I 78 I709 20 0 10 20 40 80 x7.96 I . I (IN FEET) 1 INCH = 20 FT. i cup7 = vi C�� s 8 gm�° J m 0 CLp d Q N (n Z M 1A Q b o H y kf mUv�i�E zo m > t V N m E �c m on E Z a c <. 'm a Q t 2 mom t m c 9 c ¢� [Li aLL F- Of J!. i Q W O z =L! �C 0 U / SSSS CM Y v Q O �OCJQ O � � LJLJ U) c 2 zZ Q 'RJ Z V CIDO z �� o Q � Z < 1ft--. JHU 2 9TION LLI W I O O Z O W Q O cn O N M Y M W W W I z 2 Y I SCALE: 1 "= 2 0' MOGIF're'l • 117 s SEVAIWATER AtWGEAMVr WET POND COA67MJCTM NOTES 870% WATER COLLECTION SYSMW CjyWffjAL NOTES 1. IF THE STORMWATER MANAGEMENT WET POND IS GRADED AND UTILIZED FOR SEDIMENT CONTROL PURPOSES DURING CONSTRUCTION SHALL BE CLEANED AND FINAL CONTOURS SHALL BE REESTABLISHED PRIOR TO STABILIZATION. 1. UNDERGROUND UTILITY LOCATIONS ARE APPROXIMATE AND BOTH SHALL BE FIELD VERIFIED PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION 2. VEGETATION SHALL BE ESTABLISHED ALONG ALL POND BANKS (EXCEPT EMERGENCY OVERFLOW). REFER TO THE ACTIVITIES. ADDITIONALLY, THE CONTRACTOR SHALL NOTIFY NC ONE CALL SEEDING SCHEDULE FOR TEMPORARY AND PERMANENT SEEDING REQUIREMENTS (ABOVE THE VEGETATED SHELF). THE (1-800-632-4949) 48 HOURS PRIOR TO ANY CONSTRUCTION ACTIVITIES. VEGETATED SHELF SHALL BE PLANTED AS SHOWN ON THE PLAN. 2. ALL STORMWATER MANAGEMENT PIPES 12" OR LARGER SHALL BE 3. CUT EXISTING GRADE TO 12" BELOW PROPOSED GRADE TO ALLOW FOR 12" RESPREAD OF EXISTING TOPSOIL ALONG REINFORCED CONCRETE PIPE (UNLESS NOTED OTHERWISE) INSTALLED IN VEGETATED SHELF OF POND. TOPSOIL SHALL BE TESTED TO VERIFY SOIL PH IS BETWEEN 5.5 AND 6.5 WITH 2%-10% ACCORDANCE WITH STANDARDS SET FORTH BY THE AMERICAN CONCRETE 6" ORGANIC MATTER. AMENDMENTS SHALL BE PROVIDED IF NECESSARY. PIPE ASSOCIATION. HDPE PIPE SHALL BE DOUBLE WALL, SMOOTH INTERIOR PLACED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. ALL 4. APPLY FERTILIZER PER NURSERY REQUIREMENTS. CONSULT VENDOR REGARDING FERTILIZATION REQUIREMENTS FOR OPEN PIPE ENDS SHALL BE FITTED WITH FLARED END SECTIONS OF THE INDIVIDUAL SPECIES. (SEE PARTIAL VENDORS LIST) SAME SIZE AND TYPE. 5. CONFIRM FINAL PLACEMENT OF PLANTINGS WITH LANDSCAPE PLAN. THE CONTRACTOR SHALL BE RESPONSIBLE FOR 3. ALL STORMWATER MANAGEMENT SYSTEMS SHALL RECEIVE APPROVAL FROM ESTABLISHMENT OF VEGETATIVE SHELF. RECOMMENDED TIME TO PLANT VEGETATIVE SHELF IS APRIL 1ST - JULY 15TH. THE NORTH CAROLINA DEPARTMENT OF THE ENVIRONMENT AND NATURAL CONSULT NURSERY FOR PLANTING DURING OTHER TIMES OF THE YEAR. PLANTING SHALL NOT OCCUR DURING WINTER RESOURCES - DIVISION OF WATER QUALITY. REFER TO STORMWATER MONTHS (DECEMBER 1 - MARCH 15). MANAGEMENT DRAWINGS APPROVED BY NCDENR - DWQ FOR FINAL DESIGN PARAMETERS AND OTHER PERMIT REQUIREMENTS. NO IMPERVIOUS SURFACES 6. UPON COMPLETION OF POND GRADING IMMEDIATELY PROVIDE VEGETATIVE STABILIZATION OF SIDE SLOPES AND EROSION SHALL BE CONSTRUCTED PRIOR TO PERMIT ISSUANCE CONTROL EXCELSIOR MATTING IF NECESSARY. IF REMAINDER OF SITE IS NOT STABILIZED, INSTALL SILT FENCING ALONG 4. PRIOR TO WORK, VERIFY ISSUANCE OF, LIMITS OF DISTURBANCE AND OTHER PERIMETER OF NON -STABILIZED AREAS. MEASURES STIPULATED IN THE NCDENR EROSION AND SEDIMENTATION 7. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO VERIFY POND SIZE, DEPTH AND CONTROL PERMIT. INVERT/STRUCTURE ELEVATIONS. 5. DROP INLETS SHALL BE CONSTRUCTED PER NCDOT 840. B. REFER TO STORMWATER PERMIT AS ISSUED BY THE NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY FOR ADDITIONAL CONDITIONS. STOR WATER M4NACEb6U WET POW MAMEMNCE NOTES 1. UPON ACCEPTANCE BY THE OWNER, IT IS THE OWNER'S RESPONSIBILITY TO PROVIDE NECESSARY MAINTENANCE SO THAT THE STORMWATER SYSTEM WILL FUNCTION AS INTENDED. jI 2. AFTER EVERY SIGNIFICANT RAINFALL EVENT (1.5" OR GREATER) AND AT LEAST MONTHLY, INSPECT THE SYSTEM FOR EROSION, TRASH ACCUMULATION, VEGETATIVE COVER, AND GENERAL CONDITION. ALSO INSPECT THE INFLOW STRUCTURES, CURB & GUTTERS, FLUMES, RIP -RAP, AND BASIN FOR OBSTRUCTION OR DETERIORATION. REMOVE ANY BLOCKAGE AND REPAIR THE STRUCTURE TO APPROVED DESIGN SPECIFICATIONS. REPAIR ERODED AREAS IMMEDIATELY, RE -SEED AS NECESSARY TO MAINTAIN ADEQUATE VEGETATIVE COVER, AND REMOVE TRASH AS NEEDED. 3. CHECK FOR SEDIMENTATION WITHIN THE POND ANNUALLY. REFER TO PERMIT CONDITIONS FOR REMOVAL OF SEDIMENTATION IF DEPOSITION OF MATERIAL EXCEED LIMITS NOTED FOR THE SYSTEM. INSPECT BASIN WALLS AND STRUCTURES TO ENSURE THAT THEY ARE MAINTAINED AT THEIR DESIGN ELEVATIONS. IF EROSION OCCURS, a 7M A A REESTABLISH DESIGN ELEVATIONS AS INDICATED ON APPROVED PLAN. NITS 4. ALL PONDS DESIGNATED AS STORMWATER MANAGEMENT DETENTION PONDS SHALL BE MAINTAINED BY THE COLUMBIA PARK HOMEOWNERS ASSOCIATION. EACH DETENTION POND SHALL INCLUDE A DRAINAGE AND ACCESS EASEMENT GRANTED TO THE COLUMBIA PARK HOMEOWNERS ASSOCIATION FOR PROPOSES OF MAINTAINING THE STORMWATER MANAGEMENT FACILITIES AS NECESSARY. THIS EASEMENT SHALL INCORPORATE THE ENTIRE DELINEATED POND STORAGE AREA AND SHALL EXTEND A MINIMUM OF FIFTEEN FEET BEYOND THE AREA ENCUMBERED BY THE PERMANENT POOL ELEVATION. EACH POND SHALL ALSO INCLUDE AN ACCESS EASEMENT NO LESS THAN TEN FEET IN WIDTH AND EXTEND FROM THE POND EASEMENT TO A DEDICATED RIGHT-OF-WAY. DRAINAGE EASEMENTS, NO LESS THAN TEN FEET IN WIDTH, SHALL ALSO BE GRANTED ALONG ALL CONNECTING DRAINAGE FEATURES (STORM SEWERS/ OPEN SWALES / DITCHES) CONVEYING RUNOFF TO OR FROM THE PONDS 5. BOTTOM OF POND ELEVATIONS EXTEND BELOW THE OBSERVED NATURAL GROUNDWATER ELEVATIONS. DUE TO AVAILABLE OUTLETS FROM THE SITE, NO PROVISION IS AVAILABLE TO COMPLETELY DRAIN THE POND BY GRAVITY. IN THE EVENT THIS TASK BECOMES NECESSARY IN ORDER TO PERFORM MAINTENANCE ON THE POND, THE HOMEOWNERS ASSOCIATION SHALL OBTAIN A DEWATERING PUMP OR SUBMERSIBLE NON -CLOG PUMP OF SUFFICIENT SIZE TO DRAIN THE POND AND MAINTAIN DRY CONDITIONS AGAINST GROUNDWATER RECHARGE RATES. THE PUMP SHALL DISCHARGE TO THE OUTFALL OR OTHER DOWNSTREAM DRAINAGE FEATURE. 6. THE OWNER SHALL KEEP A COPY OF THE AS -BUILT DRAWINGS ON FILE, INCLUDING OUTLET STRUCTURE ELEVATIONS (RIM, ORIFICE, WEIR, FLARED END SECTION, INLET, OUTLET AND DISCHARGE OUTLET). REFERENCE TO THE RIM ELEVATION SHALL BE USED FOR BENCHMARK PURPOSES. SPECIES RATE K-31 FESCUE 3 LB/1000 SF COMMON BERMUDAGRASS 1 LB/1000 SF WINTER RYE GRAIN 3 LB/1000 SF WAY 15 - ALLY 0 PERMNE T SEED113 SPECIES RATE K-31 FESCUE 3 LB/1000 SF COMMON BERMUDAGRASS 1 LB/1000 SF GERMAN MILLET 3 LB/1000 SF AUCANHT 15 - APRL 4 7BFOFiAm SEED10 SPECIES RATE K-31 FESCUE 3 LB/1000 SF WINTER RYE GRAIN 5 LB/1000 SF WL AMENDMENTS APPLY LIME AND FERTILIZER ACCORDING TO SOIL TESTS, OR APPLY 500 LB PER ACRE OF 10-10-10 FERTILIZER. MLLCH USE JUTE, EXCELSIOR MATTING OR OTHER EFFECTIVE CHANNEL LINING MATERIAL TO COVER BOTTOM AND SIDES OF SWALES. ANCHOR MATTING PER MANUFACTURERS RECOMMENDATIONS. HYDROSEEDING IS ALSO AN ACCEPTABLE METHOD OF TEMPORARY STABILIZATION MANIBrANCE A MINIMUM OF 3 WEEKS IS REQUIRED TO FOR ESTABLISHMENT. INSPECT AND REPAIR MULCH FREQUENTLY. FERTILIZE THE FOLLOWING SPRING WITH 50 LB/ ACRE NITROGEN. Y Y PLAN WITH GRATE & FRAME REMOVED r #5 BARS ® 3" SEE NOTE 3 2 EXPANSION JOINT TO ENGINEERS DETAILS SEE NOTE 2 CONCRETE ° SEE NOTE 1 ° V ��`� BEDDING LAYER 4"-6" MIN d SOIL 4'-6" MIN 4"-6" MIN ACO S300K TRENCH DRAIN �p p� W/ 8" CONNECTION TO THUMii�J ¢� DRAINAGE SYSTEM (SEE PLANS) NTS NOTES: 1. A MINIMUM CONCRETE STRENGTH OF 3000 PSI IS RECOMMENDED. THE CONCRETE SHOULD BE VIBRATED TO ELIMINATE AIR POCKETS. 2. EXPANSION AND CRACK CONTROL JOINTS ARE RECOMMENDED TO PROTECT THE CHANNEL AND THE CONCRETE SURROUND. 3. THE FINISHED LEVEL OF THE CONCRETE SURROUND MUST BE APPROXIMATELY 1/8" ABOVE THE TOP OF THE CHANNEL EDGE. 4. REFER TO MANUFACTURER'S LATEST INSTALLATION INSTRUCTIONS FOR COMPLETE DETAILS. C"IDROP OW-L-7 NOTES 1. USE CLASS "B" CONCRETE THROUGHOUT. 2. PROVIDE ALL DROP INLETS OVER 3'-6" IN DEPTH WITH STEPS 12" ON CENTER. USE STEPS WHICH COMPLY WITH STD. DRAWING 840.66. 3. OPTIONAL CONSTRUCTION - MONOLITHIC POUR 2" KEYWAY OR #4 BAR DOWELS X AT 12" CENTERS AS DIRECTED BY THE ENGINEER. f 4. USE FORMS FOR CONSTRUCTION OF THE BOTTOM SLAB. J 5. IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM SLAB OF BOX, ADD TO SLAB AS SHOWN ON STD. NO. 840.00, 6. CONSTRUCT WITH PIPE THROATS MATCH NG. 7. INSTALL (2) 1" WEEP HOLES AS DIREC"ED BY THE ENGINEER. 8. INSTALL STONE DRAINS, OF A MINIMUM OF 1 CUBIC FOOT OF NO. 78M STONE IN A POROUS FABRIC BAG OR WRAP, 4T EACH WEEP HOLE OR AS DIRECTED BY THE ENGINEER. 9. USE TYPE "E", "F" AND "G" GRATES UNLESS OTHERWISE INDICATED. 10. CHAMFER ALL EXPOSED CORNERS 1". 11. REFER TO NCDOT BOX DIMENSIONS. 3'-0" 3" OUTLET PIPE 3 * "D" - RIM ELEVATION #5 BARS ® 3" PLACE NCDOT CLASS I S(12" MAX DIAMETER) STD. 840.16 FRAME RIP -RAP (18" DEPTH) & GRATE OVER FILTER FABRIC 4 • "D" Ll VARIES VARIES (SEE NOTE 11) 8" 8.- SEE NOTE 11 0 0 INV. ELEVATION­-- 1" WEEP HOLES NCDOT W 9 SECTION X-X COAKIEW DWP SECTION Y-Y NTS MIN. 6" f PERMANENT VEGETATION WIDTH = 6.0' FLOW - 2:1 OR FLATTER INSTALL 12" DIAMETER PIPE (OR LARGER) SMOOTH EXTERIOR FILLED WITH EARTH OR 6"x18" CONCRETE CURB. TOP OF PIPE OR CURBING SHALL BE SET AT LIP ELEVATION. - 30' GRASSED OR UNDISTURBED LIP ELEVATION= 4.50' EROSION BLANKET STAPLED IN PLACE 0.5X POND EMERGENCY OVERFLOW (SEE PLAN FOR LOCATION) SOFT RUSH (JUNCUS EFFUSUS) OR PLUMEGRASSES (SACCHARUM SPP) 61 PLUGS ® 24" O.C. SWEET FLAG IRIS (ACORUS CALAMUS) OR LEVEL SPREADER BLUE FLAG IRIS (IRIS VIRGINICA) (SEE DETAIL) 61 RHIZOMES ® 24" O.C. 5 SECTION VIEW BLACK NEEDLE RUSH (JUNCUS ROEMERIANUS) OR (SEE PLAN FOR LOCATION) - LIZARD TAIL BLATTER SEDGE (CAREX INTUMESCENS) PLUGS \/ >' (SAURURUS CERUOUS) OR VE{7A7NE FUM WITH LEVY 92 PLUGS ® 18" O.C. b' I SOFT RUSH (JUNCUS EFFUSUS) OR SAWGRASS (CLADIUM SPP) (VEGETATIVE FILTER) PLUMEGRASSES (SACCHARUM SPP) 41 PLUGS ® 18" O.C. ARROW ARUM (PELTANDRA VIRGINICA) N.T.S. / 49 PLUGS ® 24" O.C. HOP SEDGE (CAREX LUPULINA) OR OR DUCK POTATOE (SAGITTARIA LATIFOLIA) WET 95 PLUGS ® 18" O.C. ' (,(SEE C�302 SWEET FLAG IRIS (ACORUS CALAMUS) 1 FRINGED SEDGE (CAREX CRINITA) ` FOR OR BLUE FLAG IRIS (IRIS VIRGINICA) r I 41 PLUGS ® 18" O.C. VEGETATED CONTOURS) 52 RHIZOMES ® 24" O.C. 2' VE FILTER SLOPE AND II.VERT WITH SOD AND IRRIGATE TO ESTABLISH EXISTING OR PROPOSED ASPHALT PAVEMENT BLACK NEEDLE RUSH (JUNCUS ROEMERIANUS) OR BLATTER SEDGE (CAREX INTUMESCENS) 96 PLUGS ® 18" O.C. / / v ARROW ARUM (PELTANDRA VIRGINICA) OR DUCK POTATOE (SAGITTARIA LATIFOLIA) �< 81 PLUGS ® 18" O.C. I OUTLET CONTROL STRUCTURE`." I d m � m r no '� l0 N N p� O r N Z O y V m�.� H w m SHELF I Z d m SEED AND STABILIZE ALL ADJACENT SIDE SLOPES ABOVE AQUATIC BENCH d `m a P (SEE SEEDING SCHEDULE) Q j o SWEET FLAG IRIS (ACORUS CALAMUS) OR � ,, BLUE FLAG IRIS (IRIS VIRGINICA) x., < 96 RHIZOMES ® 24" O.C. R(JUNCUS/ i \., 1 SOFT RUSH EFFUSUS) OR , �� `� \�` 1kk SWEET FLAG IRIS (ACORUS CALAMUS) OR BLUE FLAG IRIS IRIS VIRGINICA PLUMEGRASSES SACCHARUM SPP / \ \ ( ) ( ) 8 23 RHIZOMES ®24" O.C. .> ' •_,_. "' 121 PLUGS ®24" O.C... . �ZARD TAIL (SAURURUS CERUOUS) OR - / - SAWGRASS (CLADIUM SPP) 58 PLUGS ® 18" O.C. SOFT RUSH (JUNCUS EFFUSUS) OR Ip PLUMEGRASSES (SACCHARUM SPP) 4 HOP SEDGE (CAREX LUPULINA) OR 44 I 36 PLUGS ® 24" O.C. FRINGED SEDGE (CAREX CRINITA) F- 56 PLUGS ® 18" O.C. �\ \ / PERMANENT POOL LIZARD TAIL (SAURURUS CERUOUS) OR �\ INLET PIPE (SEE PLANS , ' / ELEVATION (SEE DETAIL) SAWGRASS (CLADIUM SPP) FOR LOCA ION AND DETA� / TEMPORARY POOL 59 PLUGS ® 18" O.C. \ \ ELEVATION (SEE DETAIL) HOP SEDGE (CAREX LUPULINA) OR \ IINLET PIPE (SEE PLANS TOP OF BANK FRINGED SEDGE (CAREX CRINITA) �OR LOCATION AND DETAILS) 56 PLUGS ® 18" O.C. V SHEAFED / STM WATER Ak/ANMaEAOVT WET POW DETAIL\ MINIMUM POND BANK V)SCALE: 1' = 20' ELEV. = 7.75' Z �( OVERFLOW ELEVATION (6.75') O 5' 5' 15 r 1 CLASSDOT .POOL -.. 5.9''N.5' R :>M N. 12" NCDOT CLASS 2 RIP -RAP z OVER FILTER FABRIC 4H:1V DESIRED; / 3H:1V MAX (ABOVE ELEV = 4A STORAGE ELEVATION) 1OH:1V VEGETATED SHELF (TO BE VEGETATED BY CONTRACTOR) 18" 18" .,'./FT 1"/FT 8" 3000 PSI NEATLY SAW -CUT j CONCRETE WHERE APPLICABLE VALLEY GVrrER DECAL NTS t- --- 4 ' "D" __1 INV. = 2.00' "D" = PIPE DIAMETER STaW SEWER OUTLET (&4fflQYDOWATM DETAL NTS OUTLET STRUCTUIE NOTES 1. NCDENR-DWQ APPROVAL SHALL BE OBTAINED PRIOR TO PROCUREMENT OF STRUCTURES. SHOP DRAWINGS SHALL BE APPROVED BY THE ENGINEER. 2. CONTROL STRUCTURE DESIGN SPECIFICATIONS SHALL CONFORM TO LATEST ASTM C913 SPECIFICATIONS FOR "PRECAST CONCRETE WATER AND WASTEWATER STRUCTURES." 3. CONCRETE CO9PRESSIVE STRENGTH 4,000 PSI MINIMUM. 4. STEEL REINFORCING DESIGN TO CONFORM TO THE REQUIREMENTS OF ASTM C890 SPECIFICATIONS FOR "STRUCTURAL DESIGN LOADING FOR WATER AND WASTEWATER STRUCTURES" AND SHALL UTILIZE GRADE 60 RE -BARS CONFORMING TO THE REQUIREMENTS OF ASTM A615 OR WWF CONFORMING TO THE REQUIREMENTS OF ASTM A185 OR BOTH. 5. STRUCTURES SHALL BE DESIGNED FOR H-20-44 LOADING. 6. STEPS REQUIRED ON CATCH BASINS OVER 3'-6" IN DEPTH. STEPS SHALL BE STEEL REINFORCED COPOLYMER POLYPROPYLENE PLASTIC AND MEET THE REQUIREMENTS OF ASTM C478. 7. FRAME GRATE SHALL BE DOUBLE INLET NEENAH R-3580-1 OR APPROVED EQUAL. 8. JOINTS TO BE SEALED WITH BUTYL RUBBER JOINT SEALANT CONFORMING TO THE REQUIREMENTS OF ASTM C990, OR MORTAR AS PER NCDOT REQUIREMENTS OR BOTH. 1 V MAX 1 STONE GABION/ RIP RAP 3' 1 V MAX h1r.-4mKTju1jkiT11IyI7ii F,T�,V 151F7TZ:iAi%-ANX:p1"'10L�'\� iiiiiiiiiiiii OUTLET ELEV. = 4.00' U 0 2 OUTLET STRUCTURE (SEE DETAIL) o 3H:1 V MAX O z i SEE POND DETAIL SHEET INSTALL TEMPORARY PIPE END CAP DURING CONSTRUCTION. REMOVE UPON STABILIZATION OF SITE (SEE SHEET C101). PRECAST CONTROL STRUCTURE WITH INTERGRALLY CAST INTERIOR WEIR AND ORIFICE RIM ELEVATION = 7.50' " 8" N (SEE PLANS FOR DETAIL) PLAN IN VIVID C� DOUBLE FRAME AND GRATE z CD O J � a Of Of O W Z 0 Z OZ g � CC ^ O E LLJ Y Q LLJ O V7 Z v J HO QZ V O z CD (Q co Z V z U V J w PERMANENT POOL / / /\/j\/j /�// OUT 2'-6" 2 -6" ELEVATION N y' w �a�dLjt =ii' /////\// - MIN. MIN. :7,-;mot o L n / //\/�'//\/•:,-. \ z 0) o o Ld FLARED END cn m Y w SECTION WITH IN 8 TRASH RACK IN 3'_0" 8" 0 w -i INV. IN = 2.50' / 6" SUMP BOTTOM OF STRUCTURE = 2.00' y 0 o o m x %/% T SCALE: 18" RCP WITH FLEXIBLE GASKETS AND RUBBER TO CONTROL BOOTED CONNECTION STRUCTURE (TYP.) 3'-0" 3'-0" ABC BASE 98% COMPACTION) (98 C303 SECTION A -A WET DETENTION POW OUTLET STAUCIUE NTS M