Loading...
HomeMy WebLinkAboutNCC216350_Site Plan or Location Map_20211118C VICINITY MAP NOTTO SCALE s,apo' SITE e,,61 sa Po J-r RA.,9 Nufab Re 9 O SITE INFORMATION CURRENT OWNER: JARCO PROPERTIES LLC MAPN: 088603022732 PLANNING JURISDICTION: TOWN OF BUTNER COUNTY. GRANVILLE STATE: NORTH CAROLINA MAP & DATA REFERENCE. GOOGLE AERIAL & EARLY COUNTY TAX MAP DEED BOOK/PAGE. 0162110479 TOTAL AREA: SAC FEMA PANEL#. N/A FEMA ZONE. N/A EXISTING USE. VACANT/ UNDEVELOPED PROPOSED USE. 7,260 SF OFFICE/ WAREHOUSE EXISTING ZONING: LI ADJACENT ZONING: LI (EAST) LI (SOUTH) LI (WEST) LI (NORTH) ZONING OVERLAYS: NONE NOTED WATER PROVIDER: SGWASA SEWER PROVIDER: SGWASA WATERSHED: UPPER FALLS LAKE EROSION CONTROL DISTURBANCE THRESHOLD: 1 ACRE STORMWATER DISTURBANCE THRESHOLD: 12,000 SF PARKING REQUIREMENTS: INDUSTRIAL USE = 1 PER EMPLOYEE ON LARGEST SHIF TOTAL PARKING REQUIRED: 6 EMPLOYEES = 6 SPACES PARKING PROVIDED: 7 SPACES (6 STANDARD, 1 VAN ACCESSIBLE) REQUIRED PROPOSED STRUCTURE SETBACKS FRONT SETBACK: 40' 90.40' SIDE SETBACK. 35' 114.29' (EAST), 94.99' (WEST) REAR SETBACK. 40' 170.52' SIGN SETBACKS: 70' MAXIMUM BUILDING HEIGHT. 50' 19.5' MAXIMUM SIGN HEIGHT. 8'(MONUMENT) 25'(POLE) EXISTING IMPERVIOUS AREA: 0 SF (0.009/6) IMPERVIOUS AREA TO BE DEMOLISHED: 0 SF (0.0091o) PROPOSED IMPERVIOUS AREA: ±38,322 SF (±17.609,o) TOTAL IMPERVIOUS AREA: ±38,322 SF (±17.609,o) PROPOSED IMPERVIOUS AREA CALCULATIONS: BUILDING ±7,260 SF CONC. SIDEWALK ±2,414 SF GRAVEL ±19,975 SF DRIVE/PARKING ±8,673 SF TOTAL ±38,322 SF SITE & UTILITY NOTES: SSMH RIM 373.56 RICHARD & DENISE FISHER 087604937020 DB 0096710098 CITY OF BUTNER ZONING: RS SIZE. I AC vy F l O� l �') ti \ C� ti CHRISTOPHER JR & FELIC JOHNSON \ 087604926980 / DB 0096610037 CITY OF BUTNER �h ZONING: RS p •D SIZE. I AC S1. SURVEY DATA AND LOCATIONS PROVIDED BY STEPHEN M. PUCKETT, PLS, DATED 01118120. FIELD VERIFY EXISTING CONDITIONS BY DETAILED SITE INSPECTION PRIOR TO SUBMITTING BID AND BEGINNING CONSTRUCTION. NOTIFY ENGINEER OF ANY DISCREPANCIES. S2. ALL SITE CONSTRUCTION SHALL BE IN ACCORDANCE WITH TOWN OF BUTNER CODE, NCDOT STANDARDS AND OTHER APPLICABLE SPECIFICATIONS AS DIRECTED ON THE PLANS AND DETAILS. S3. ANY APPLICABLE OR REFERENCED SPECIFICATIONS SHALL SUPERCEDE ANY DETAILS PROVIDED OR REFERENCED. S4. CONTRACTOR SHALL MAINTAIN ANY EXISTING ACCESSES TO ADJACENT RESIDENCES, BUSINESSES AND PROPERTIES AT ALL TIMES. S5. CONTRACTOR IS RESPONSIBLE FOR OBTAINING OR INSURING THEY HAVEANYAND ALL PERMITS NECESSARY FOR CONSTRUCTION. S6. ALL OUTDOOR STORAGE SHALL BE SCREENED FROM PUBLIC VIEW BY OPAQUE FENCING, SCREENING, OR LANDSCAPING, LIMITED TO REAR AND SIDE OF THE PRINCIPAL BUILDING, IF HAZARDOUS AND/OR UNSAFE, SHALL MEET ALL LOCAL, STATE AND FEDERAL ENVIRONMENTAL REQUIREMENTS, AND MUST BE ON THE PREMISES OF THE BUSINESS. S7. ALL SITE AND BUILDING LIGHTING SHALL BE DIRECTED SO THAT IT DOES NOT SPILL OVER ONTO ADJACENT PROPERTY OR RIGHT-OF-WAY. U1. ALL NEW UTILITIES SHALL BE LOCATED UNDERGROUND UNLESS OTHERWISE NOTED. U2. ALL UTILITY CONSTRUCTION SHALL CONFORM TO SGWASA STANDARDS AND SPECIFICATIONS. U3. IF REQUIRED, PRIOR TO THE CONSTRUCTION OF ANY WATER OR SEWER MAIN EXTENSIONS, TAPS OR RELOCATIONS, THE ENGINEER OF RECORD SHALL BE CONTACTED BY THE GENERAL CONTRACTOR TO DISCUSS CERTIFICATION REQUIREMENTS. FAILURE TO CONTACT THE ENGINEER OF RECORD OR PROVIDE ANY OF THE REQUESTED DOCUMENTATION DISCUSSED MAY RESULT IN THE INABILITY OF THE ENGINEER TO CERTIFY THE LINE AND POSSIBLE REPLACEMENT. U4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF THE LOCATION AND/OR RELOCATION OFALL EXISTING UTILITIES WITH THE APPROPRIATE UTILITY, AGENCY OR COMPANY. U5. AS IS STANDARD PRACTICE, IT IS ASSUMED THAT THE BUILDING CONTRACTOR AND ASSOCIA TED PLANS ARE RESPONSIBLE FOR CONTINUATION OF ALL UTILITIES WITHIN 5' OF THE BUILDING PERIMETER. PRIOR TO CONSTRUCTION, THE GENERAL CONTRACTOR SHALL REVIEW BOTH SITE AND BUILDING PLANS WITH THE SITE UTILITIES CONTRACTOR AND PLUMBING CONTRACTOR TO ENSURE THAT THEYARE CLEAR ON THE TERMINUS POINTS AS WELL AS HOW EACH WILL TIE TO THE OTHERS WORK. U6. ALL PIPE INVERTS, TAP LOCATIONS & AVAILABLE CLEARANCES TO BE VERIFIED IN THE FIELD PRIOR TO CONSTRUCTING STORM & UTILITY SYSTEMS AND SHALL BE ADJUSTED BY THE ENGINEER IF NECESSARY. FAILURE TO REVIEW THESE ITEMS AT THIS TIME WILL RESULT IN THE CONTRACTOR BEING WHOLLY RESPONSIBLE FOR THE FIELD REVISIONS AND ASSOCIATED DESIGN COSTS OF THE SOLUTIONS PROPOSED. Know what's below. Call before you dig. � d r LOCATION OF EXISTING 8" GRAVITY LINE. \ \ ss 28 TOP = 329.15 INV. = 325.15 EXTEND NEW 4" PVC FROM SITE, UNDER ESTATE DRIVE (VIA OPEN CUT), AND DOWN TO GRAVITY LINE. / LOCATE & MARK EXISTINGSERqCES & LIMITS OF EASEMENT PIYO DOING WORK. EXTENI 3 2% KEEPING A MIN. 3' CO,V ALL - TIMES. / \ SS/ SS� S� R moo 'Z -III 28 75LF-4" TOP =335.90 PVC @ 4.33% INV. = 332.00 75LF-4" 28 PVC @ 9.13% TOP = 338.55 INV. = 335.25 TONY R & JO ANN S SKIPPER 088603028512 DB 0707910567 CITY OF BUTNER ZONING: LI SIZE. 5.13 AC SEWER TAP INSET SCALE. V = 40' TOP = 326.15 INV. = 319.15 75LF-4" PVC @ 8% 5 LF - 4" PVC @ 19.4% EXIST. SSMH RIM 328.75 INV. IN 377.86 INV. OUT 317.76 APROX. ±318.18 APPROX. ±318.15 . 351.5 ; �•-•-• 1T.x-fit SEWER SERVICE INSET SCALE. V = 40' \� 1 " METER 1 " D,CDA BACKFLOW PREVkNTER IN ABOVE GROU D HEATED ENCLOSURE � 45° BEND \ 31 4�� WATER SERVICE INSET Calculated Point A Fire Hydrant )C� Electrical Pedestal EP Septic Utilities SU Power Meter PM Septic Tank ST Clean Out COQo Catch Basin CB Gas Meter GM Storm Drain Pipe SD Screened Porch SP Concrete CC Covered Porch CP Area Light �7 Deck DK Utility Pole H.V.A.C. HV Sanitary Sewer Manhole S Retaining Wall RW Overhead Utilities CHU Asphalt Pavement AP Gas Line ---- G---- Brick Pavers BP Water Line ---- W---- Stone Pavers SP Telephone Cable ----- T---- Concrete CC Property Line Curb Inlet Cl Right of Way Line Yard Inlet YI Deed or Plat Line Drainage Pipe DP Property Line Tie Water Valve D4 Overhead Utility Line Fiber Optic FO Fire Department Connection FDC FO Marker Post FP Gas Valve GV Fiber Optic Vault FV Corrugated Plastic Pipe CPP Traffic Signal Vault TSV Fire Protection Valve FPV Cable Vault CV Telecommunications Vault TV Traffic Signal Box TSB Utility Vault UV GRAPHIC SCALE 20 0 10 20 40 80 (IN FEET) 1 inch = 40 ft. W Q aQ`Nr' o 0 w �Lr� U N U U L� J J 31 L = a LI n z O - 11 Ln Lw UI W Wz o o Lo azOzN ❑W� yQQN o: h ZU = 00 uzrn O�la �0 OEM LjiWm�C�JN J k0 O v i�G UFO z r\j vat NOT FOR CAttF���i ZZ Cr r F'ok #001 CONSTI1[JCTION N � N � W 0 o 0 � Q o W P4 ,-,-)Ifnl-tI(r)INI- V 1� M U" W W� N N � rr^^ vJ U 1 W W L) rr^^ vJ O O f-�I UaW '✓C' U � o V J C3 PROJECT #: 19-048 REVIEW PROJECT #: SHEET # C-1.3 = 10'