Loading...
HomeMy WebLinkAboutSW7130504_APPROVED PLANS_20130628TYPE I o CURRENT STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW DOC TYPE ❑ CURRENT PERMIT m'.oPwo�Eo.�nxs APPROVED PLANS ❑ HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC oo�DATE ur�eCA�p�EE�<.�..�o YYYYMMDD J i _f. 11 . I 7.0 F �.J VICINITY MAP NTS SITE DATA 1, DEVELOPER: EASTERN PRIDE, INC. BARNES BOYKIN, SECRETARY 2405 W, NASH STREET, SUITE F OLSON, NC 27893 252-230-0632 2 SITE INFORMATION: PIN # 891307670525 (PORTION OF? D.B. 220. PG, 343 CITY MAP,/LOT:49-E (PORTION OF) SITE AREA: 58.959 SF = 1.35 AC ZONING: GB - GENERAL BUSINESS ADDRESS: 709 W. EHRNGHAUS ST. (US HWY 17 BOS) 3, MINIMUM BUILDING SETBACKS: STREET = 20' (EHRI.NGHAUS ST.) SIDE - 20' (WESTOvIER ST.) REAR - 15' N/F BOYS AND GIRLS CLUB OF ELIZABETH CITY D.B. 220, PC, 343 EXISTING PAVEMENT PIN: 891307670525 ZONED: R-6 EXISTING CONCRETE CURRENT USE: BALL FIELDS FUTURE USE: UNKNOWN BUILDING SETBACK BUFFER YARD SETBACK RIGHT OF WAY LINE UTILITY EASEMENT INGRESS/EGRESS EASEMENT FLOODZONE EXISTING WATERLINE EXISTING STORM CULVERT EXISTING SEWER LINE EXISTING OVERHEAD TELEPHONE EXISTING UNDERGROUND ELECTRIC EXISTING FENCE EXISTING CONTOUR EXISTING TOP OF BANK EXISTING DITCH TEMPORARY BENCHMARK EXISTING FIRE HYDRANT EXISTING WATER VALVE EXISTING SEWER MANHOLE EXISTING UTILITY POLE EXISTING CURB INLET EXISTING DROP INLET EXISTING STORMWATER FLOW DIRECTION R/W MONUMENT EXISTING IRON REBAR CALCULATED POINT EXISTING SIGN EXISTING 4" X 4" POST EXISTING UGHTPOLE AND CONCRETE BASE pvv yyvvv t� \ \\ \ , \° N/F I� v� DARRELL L ROGERS TRUST y� .i I .\'•- D.B. 1144, PG. 261 \W j ___ \\� PIN: OUT OF 891307670525 30 X2t i ZONED: GB k INGRESS/EGRESS -\ \\ CURRENT USE: BOYS & GIRLS CLUB- r & UTILITY _ FUTURE USE: SONIC DRIVE—IN RESTAURANT - j EASEMENT \ \\ D.B N/A, PC. NA PIN: 89131167541 50 •\� \\\ ��� PIN: 89130?6'n 760 ZONED: Ge \ \\ n vv, IN. ZONED: GB USE: NATIONAL GUARD ARMORY rn ___._ - ---- >\L— -- USE RETAC� vv --- ? ¢ \ bJL LITiON`_; PROIA THE GROUND, UP Hyman & Robey, PC 150 US H',vy 158 E. PO Box 333 Carliden, NC 27021 (252) 338-2913 !252; 338-5552 fax w-evvi hynianrobey.com bcense C-0598 SITE PLAN N0.^- Dc: M /ag r • 20 / Smrmwa?erPerntit(11� ELIZABETH CITY PASQUOTANK COUNTY NORTH CAROLINA Knowwnaft below. Call bef n you dig. Project #: 130042 Drawing #: 13M42-�TEPLA:r g Drawn: JLE Checked: KDH Approved: SCR Date: 5t3F2013 Sheet #: 01111 Scale: 1:20 REVISIONS: NUM, DATE DESCRIPTION 1 5r2112013 DRAFTING RF,V)&ON9 SHEET TITLE: EXISTING CONDITIONS SHEET NUMBER: I VICINITY MAP NTS LEGEND LN :s SITE DATA 1, DEVELOPER: EASTERN PRIDE, INC. BARNES BOYKIN, SECRETARY 2405 W. NASH STREET, SUITE F WILSON. NC 27893 252-230-0632 2. SITE INFORMATION: PIN K 891307670525 (PORTION OF) Q.B. 220, PG, 343 CITY MAPfLOT:49-E (PORTION CF) SITE AREA: 58,959 SF = 1.35 AC. ZONING: GS -- GENERAL BUSINESS ADDRESS: 709 W. EHRINGHAUS ST. (US HWY 17 BUS .3. MINIMUM BUILDING SETBACKS: STREET = 20' (EHRINGHAUS ST.) SIDE = 20' (WESTOVER ST..) REAR = 15' NjF BOYS AND GIRLS CLUB OF ELIZABET:H CITY D.B. 220, PG. 343 EXISTING PAVEMENT PIN 891307670525 �- -N ZONED: R-6 �� CURRENT USE: BALL FIELDS EXISTING CONCRETE FUTURE USE:UNKNOWN i N/` i •�� DARRELL L. ROGERS TRUST x�� � $$$ ivy D.B. 1144, PG. 26t arc ix� BUILDING SETBACK / -- PIN: OUT OF 891307670525 3fl'x21 ZONED: GB BUFFER YARD SETBACK ! € f DRESS,.. NC SU EG ` r. \\ BOYS & GIRLS ENTUSE: USE:SONIC & UTILITY FUTURE USE: SON C DRIVE N RESTAUR F TUBE RESTAURANT RIGHT OF WAY LINE v, EASEMENT-_ t� UTILITY EASEMENT - \\\\\\\\\ ii vI� INGRESS/EGP.ESS EASEMENT —3F—aMENT: i FL000zaNE _..._ EXISTING WATERLINE 3b— X5 5'INGRESS%EGRESS EASEXISTING STORM CULVERT±92 LF OF SIDEWALK ANDEXISTING _. _.... _._ =`- -- - _._.._. -- --- "� VED FOR CUR�RiVEWAY(BYTO BE OOTHEfiS), SEWER LINE.. NEW NT 59' 3"'Vk EXISTING OVERHEAD TELEPHONE d 355.48' EXISTING UNDERGROUND ELECTRIC E " EXISTING -35 MPH SPEED r LIMIT" SIGN TO BE REMOVED 3 EXISTING FENCE � �' :. - EXISTING 4'X4" POST AND RELOCATED BY OTHERS d � TO BE REMOVED ' r EXISTING CONTOUR T , EXISTING TOP OF BANK EXISTING DITCH Y ALL FENCE AND POSTS THE LIMITS---r�r--'--' ,.. i 4F DISTURBANCE TO BE REMOVED ,m TEMPORARY BENCHMARK' EXISTING FIRE HYDRANT i ,- ALL UNDERGROUND ELECTRIC WIRE Z AND CONDUIT TO BE REMOVED EXISTING WATER VALUE � EXISTING SEINER MANHOLE :_ " r EXISTING UTILITY POLE .Q _,} :, I TO BE REMOVED w EXISTING CURB INLET Dr Is EXISTING DROP INLET M , V W i EXISTING STflRMWATER FLOW DIRECTION I i F .€ t t i *`SAW CUT AND REMOVE EXISTING PAVEMENT AS NECESSARY. REPAIR AREA PER PAVEMENT REPAIR DETAIL I I I E i P,• co I r i N/F cc:v, � \ N;F <>` MALLETT P, EVANS .`>� � STATE OF NORTH CAROL -NA 'Q , v f 7 D 1 �. D.B. 474, PG. 587 vv i 1 PIN: 891307672760 D_B. NfA, PG. NfA v PIN: 89?311675450 �.�. ZONED: GB .:.. r ,I _ ZONED: GB � v>" USE: RETAIL USE: NATIONAL GUARD ARMORY— GRAPHIC SCALE 20 0 10 20 40 ( IN FEET ) I inch = 20 It, Q0I­I­I1FW_',NS FROM, THE 'GROUND UP }'Iymaa'm & Rf1bey. PC "1 150 US Hwy 158 E. PO BOX 339 Camden, NC 27921 f252I'38-291 €2523 333-5552fax vvw v.hylnanrabey-coin License C-0505 18550 C. SITE PLAN Im #100 RELOCATION ELIZABETH CITY PASQUOTANK COUNTY NORTH CAROLINA Know whars below. Call be%e yuu dig. Project * 130042 Drawing * i?rxax-ODTeo a Drawn: JLE h C ecked: KDH Approved SCR Date: 513,12013 Sheet* 02/11 Scale: 1:20 REVISIONS: NUM. DATE DESCRIPTION I E.21r2013 DRAFTING RE9SION5 SHEET TITLE: DEMOLITION PLAN SHEET NUMBER: C 1 01 "t VICINITY MAP NTS SITE DATA: 1, DEVELOPER: EASTERN PRIDE, INC. BARNES BOYK€N, SECRETARY 2405 W. NASH STREET, SUITE F WILSON, NO 27893 252-230-0632 1 SITE INFORMATION: PIN A 891307670525 (PORTION OF" D.B. 220, PG. 343 CITY MAP/LOT:49-E (PORTION OF) SITE AREA: 58,959 SF = 1.35 AC. ZONING: GB - GENERAL BUSINESS ADDRESS: 709 W. EHRINGHAUS ST, (US HWY 17 BUS" 3. MINIMUM BUILDING SETBACKS: STREET = 20' (EHRINGHAUS ST.) SIDE = 20' (WESTOVER ST% REAP. = 15' 4, PARKING REQUIREMENTS: BUILDING AREA = 9,100 SF STORAGE AREA = 750 SF GROSS RETAIL AREA - 8,350 SF REQUIRED PARKING 0 1/200 SF GROSS FLOOR AREA = 42 REGULAR SPACES PROVIDED =42 ADA SPACES 0 1 PER 25 REGULAR SPACES = 2 TOTAL PARKING SPACES PROVIDED = 44 5. SITE IS LOCATED IN FLOOD HAZARD ZONE "AE(5.2)", SHADED "X" AND "X" AS SHOWN ON F.I.R.M. PANEL 3720891300J, DATED OCTOBER 5, 2004. 6. THIS IS NOT A BOUNDARY SURVEY, BOUNDARY LIMITS SHOWN TAKEN FROM PLAT ENTITLED "PLAT OF CORRECTION FOR BOYS AND GIRLS CLUB OF ELIZABETH CITY, NC", PREPARED BY BOWMAN CONSULTING GROUP, LTD., PAUL J, TOTI, PLS: DATED APRIL 18, 22013 7, THERE ARE NO WETLANDS WITHIN THE PROJECT LIMITS. t r - EXISTING PAVEMENT N/F BOYS AND GIRLS CLUB OF ELIZABETH CITY D B. 220, PG, 343 T\\�".- e r^.�,,, ,. - PROPOSED PAVEMENT PIN 891307670525 ZONED: R-6 . - ". .' CURRENT USE: BALL FIELDS EXISTING CONCRETE FUTURE USE:UNKNOWN PROPOSED CONCRETE 6UILDING SETBACK - - - - - - - - - - - - - BUFFER YARD SETBACK — — -- RIGHT OF WAY LINE UTILITY EASEMENT --"-'- INGRESS/EGRESS EASEMENT FLOODZONE - - 1,-------- W- — EXISTING WATERLINE ......... - --- -- -- EXISTING STORM CULVERT - ---""'--' EXISTING SEWER LINE -:-i - ----- EXISTING OVERHEAD TELEPHONE -J E -'- "----- EXISTING UNDERGROUND ELECTRIC EXISTING FENCE --- ------- - -- -- --"' EXISTING TOP OF BANK ._.. __........_ _.._ „�_. _ PROPOSED TOP OF BANK - --- --- ---- EXISTING DITCH TEMPORARY BENCHMARK EXISTING FIRE HYDRANT 'kV �Q EXISTING WATER VALVE s; EXISTING SEWER MANHOLE EXISTING UTILITY POLE EXISTING CURB INLET EXISTING DROP INLET PROPOSED DROP INLET �y < ` ® PROPOSED DOWN SPOUT a z `<"--- EXISTING STORMWATER FLOW DIRECTION 0 R/A' MONUMENT © EXISTING IRON REBAR CALCULATED POINT -::- EXISTING SIGN EXISTING 4" X 4" POST a. EXISTING LIGHTPOLE AND CONCRETE BASE FLOODZOX a PROPOSED WATER METER k" fIOODZONE i ah'ADED X^ ---_ ✓ - LEGEND LANDSCAPING t i\ PROPOSED LACEBARK ELM (15) . - (Utmvs gmrtijbdia) PROPOSED MALE GINKGO {12) `t 'ryn�y (Ginkgo 69oba) ALL CANOPY TREES TO BE A MINIMUM OF 10% OF THEIR MATURE HEIGHT AT THE TIME OF PLANTING sd PROPOSED CAMELLIA (3) A: (Camellia =snnyva) c PROPOSED BURGUNDY LOROPETALUM (89) (Loropeiatum rhiniInse) PROPOSED FRANCIS MASON (78) (Abelta Gen.ndi,Rom) ALL SHRUBS TO BE A MINIMUM OF 12" TO 18" TALL / 3 GALLON SIZE AT THE TIME OF PLANTING NOTE: ALL LANDSCAPED AREAS TO BE COVERED WITH 4" HARDWOOD MULCH. ALL OTHER UNIMPROVED AREAS TO BE SEEDED PER SEEDING AND MULCHING SPECIFICATIONS ON SHEET S. z f� l 8. SITE COVERAGE CALCULATIONS BUILDING : 9,100 SF CONCRETE: 3,198 SF LANDSCAPED AREAS IMMEDIATELY ADJACENT TO SHRUBS ASPHTOTAL F 24778 S F, SHALL BE MULCHED AND REMAINING AREAS SHALL BE TOTAL COVERAGE; 37,668 SF GRASS GROUND COVER ALL OTHER OPEN AREAS SHALL BE SEEDED OR SOD AND STABILIZED PER THE SEEDING SCHEDULE. 9. �Ny^pPfNC• REOLIIRFM NT FQP PARK_ N^ AREA LANDSCAPING MUST BE INSTALLED AS SHOWN ON THIS $TREE751DE BUFFER' PLAN. CHANGES MUST BE APPROVED BY THE CITY OF REO'D BUFFER = 1 CANOPY TREE PER 50 LINEAR FEET OF ELIZABETH CITY DEPARTMENT OF PLANNING & COMMUNITY STREET FRONTAGE DEVELOPMENT PRIOR TQ INSTALLATION, SHRUBS PLANTED 4' ON CENTER REQUIRED LANDSCAPING SHALL NOT BE PLANTED IN THE NCDOT RIGHT—OF—WAY. STREET FRO?d TAGE = 539 L.*` — 60' OF DRIVEWAY OR A73 Lf 479/50 == 10 CANOPY TREES 10. ALL SIGNS SHALL REQUIRE A SIGN PERMIT_ 479/4 = 120 SHRUBS 11. ALL UTILITY CONNECTIONS SHALL CONFORM TO THE CITY OF ELIZABETH CITY STANDARDS AND SHALL BE COORDINATED WITH THE CITY OE VEHICULAR SQFfACE AREA: ELIZABETH CITY PUBLIC WORKS DEPARTMENT. EXISTING UTILITY TOTAL 'VEHICULAR SURFACE AREA. = 24.770 SF CONNECTIONS SHALL BE UTILIZED. REO'D SHADING = i CANOPY TREE EVERY 2000 SF 12, CONTRACTOR SHALL INSPECT AND MAINTAIN AS NEEDED ALL EROSION SHRUB EVERY 5O0 Sr CONTROL DEVICES ON A WEEKLY BASIS AND AFTER EACH MAJOR STORM EVENT. FAILURE TO KEEP EROSION CONTROL DEVICES IN GOOD 24,770/2000 = 12 CANOPY TREES REO'D WORKING ORDER MAY RESULT IN THE ISSUANCE OF A STOP WORK 24,770/500 = 50 SHRUBS REO'D ORDER. LANDSCAPE ISLAND& IISLAND AND CANOPY TREE PER 13. ANY FILL BROUGHT ON SITE SHALL BE FROM AN APPROVED SITE/MINE, EVERY 'O PARKING SPACES ANY MATER: AL REMOVED FROM THE SITE SHALL BE DISPOSED OF IN A SINGLE. APPROVED LOCATION. 44 SPACES/ 10 = 5 ISLANDS REO'D 14, DISTURBED AREA WILL NOT EXCEED 2 ACRES_ TOTAL TREES REQUIRED = 27 TOTAL TREES PROVIDED — 27 TOTAL SHRUBS REQUIRED = 170 TOTAL SHRUBS PROVIDED = 170 I \\ ` IE :w C vv DARRELL L. ROGERS TRUST \\� D,B, 1144, PG. 261 1 30'X21ti' F T O PI N: I: UO891307570525 ZONED: GB vv :NGRESSi'rGRES; `- \o CURRENT ate`. USE: BOYS & GIRLS CLUB ilITY & tiTFASEMEN7 - '` FUTURE USE: SONIC DRIVE-IN RESTAURANT v " Flo i 0 �' t 0 \: iNGRESS/EGRESS EASEMENT ... F: N7' 59 37"W i 395 48' -3--5✓ ? PAC -� —+I 10 a.ra 9100 SF BUILDING FANCILY DOLLAR STORE FFE = 8.00 ,3,. BUILDING SIGN ITEM "C" 3Z5 LINEAR CLOUD WI/ 4' MEDALLION P, YARD ENTRY DOOR a r kix`Y t 7 F • M m in o I 7 N A f z �E x 4J 4 - (: t' {{^\ i IT 6,it r r d;fit , F S h rw v -'.( .. e.. iIj a '„ i�t.. -X g Y `*�" TM' "' h ._i_,_—i-: •\ ..____ C. G )'., :. C. ...':: -.-:_.._ 1:...,r: :Tc` n ___-.f-^.*-^n-xe'�.....--._-. ., •. t C. ,: ': . f J ., i SSf i .ry ^.•" \ is ., ..., .. \ >\rx . Rid .. .. X. Y,X . N VX . \` �'L.Xo'a �' �.0 4 WALK/71' ,�-+. :. ..,., �_... .... .. :. \.:: L=89.22' R:. ., __ ,,,� N :'!:'" C.,^..: :. 292.79 ,=:..,,. 4=- CONCRETE SIDEWALK — ya. _.,_.. ,_.......,- ,.. .._.__,.,,,,. X>:59_r__E - �. _...... .......... ... ____. --__ ­.-_ : D T I E. i FLOODZDNE "SHADED -• ..._=7 X" -- " -N81' 58' 27" 30.12' :. -_-- F' OCbZONE "AE(5.2)"XzTITIAIG DI i y: ' [T TBM - yM ELEV PK NAIL IN INTX /P yy I pp &52 ;•' ' WESTOVER OVER ST, ,(60 R/W) ; I ;IC , N fW% = (NAVID LTV} »,J��Y 1 'r V •<.§ : 1 t E i Imo', 4 "FIT [ _ 1.12 -- F— i a. LLJ N%F `-,` HALLETT P„ EVANS STATE OF NORTH CAROLINA - < \\• D.B. 474, PG 587 _ •, D.B. 5' P& N/A PIN: $91311675450 ZONED: I - Lu .� v`- \\: PIN: 891307612760 ZONED: GB .\\ �•v. h� 1 r ` , :; A GB USE: NATIONAL GUARD ARMORY .___ \\ ____ .� �-- _ -. _ __- USE: RETAIL I e� 20 0 i 3 E I ii x� i 1 zl I I' 1 t� \ i i E 3 I f I I t: t I 4 I I i t , 3 T \ \\ \ ( IN FEET ) i inch = 24 ft, Sa:`FLUTION ; FRONI9 THE GROUND UP Hyman & € obey, ITC 150 US Hwy 158 E. PO Box 339 Camden, NC 27921 ;252" 338-2913 (252) 338-55 52 fax www.hymanrobey.corn License C-0598 9 18550 SfihG1NEF�4y nnnoµt``� `fit i SITE PLAN FOR FAMILY DOLLAR STORE RELOCATION i i is l 1 1' ELIZ ABETH ETH CITY PASQUOTANK COUNTY NORTH CAROLINA Know whaft below. Call bef ft Wu du. Project #: 130042 Drawing #: Drawn: JLE Checked: KDH Approved: SCR Date: 513/2013 Sheet #: 03111 Scale: 1:20 REVISIONS: NUM. DATE DESCRIPTION 7 5.1Z112013 DRAFTING REVISIONS UPDATED SITE DATA SHEET TITLE: SITE PLAN SHEET NUMBER: VICINITY MAP NTS SITE DATA: 8. SITE COVERAGE CALCULATIONS: 1. DEVELOPER: EASTERN PRIDE, INC. BARNES BOYKIN. SECRETARY BUILDING 9,1Do SF LANCSCAPED AREAS IMMEDIATELY ,ADJACENT TO SHRUBS 2405 W. NASH STREET, SUITE F CONCRETE: 3,198 SF SHAG BE MULCHED AND REMAINING AREAS SHAD. BE WILSON, NO 27893 ASPHALT: 24?=sc..aE GRASS GROUND COVER. AL. OTHER OPEN AREAS SHALL 252-230-0632 TOTAL COVERAGE; 37,068 SF BE SEEDED OR SOD AND STABILIZED PER THE SEEDING SCHEDULE, 2. SITE INFORMATION: P!N k 89130767-3525 (PORTION OF) 9. LAND5 A .N RF^•�IIR MENTS FOR PARKING AREAS: LANi SCAPiNG MUST BE INSTALLED AS SHOWN ON T41S D.B. 220. PG. 343 PLAN. CHANGES MUST BE AP43,ED BY THE CITY OF CITY MAP; LOT:49-E (PORTION OF? STREETSIDE BUFFER ELIZABETH CITY DEPARTMENT OF PLANNING & COMMUNITY SITE AREA: 58,959 SF = 1.35 AC. REDID BUFFER = . CANOPY TREE PER 50 UNEAR FEET OF DEVELOPMENT PRIOR TO INSTALLATION_ ZONING: GB - GENERAL BUSINESS STREET FRONTAGE ADDRESS: 709 W. EHRINGHAUS ST:. SHRUBS PLANTED 4' ON (.ENTER REQUIRED LANDSCAPING SHALT. NOT BE PLANTED IN THE (US HWY 17 BUS; NCDOT RIGHT -OP -WAY. STREET FRONTAGE = 539 L - 60' OF DRIVEWAY OR 479 LF 3. MINIMUM BUILDING SETBACKS: STREET = 20' (EHR!NGHAUS ST.) 479''5O = 10 CANOPY TREES r E 10, ALL SIGNS .HALL REWIRE A. SIGN PERMIT. SIDE = 20''WESTOVER ST.) 479/4 = 120 SHRUBS 11. ALL. UTILITY CONNECTIONS SHALL CONFORM TO THE CITY OF ELIZABE TH REAR = 15 'CITY STANDARDS AND SHALL BE COORDINATED WITH THE CITY OF ELIZ.ABETH. CITY PUBLIC WORKS DEPARTMENT. EXISTING UTILITY VEHICULAR SURFACE AREA CONNECTIONS SHALL BE UTILIZED. 4. PARKING REQUIREMENTS: TOTAL VEHICULAR SURFACE AREA = 24,770 SF BUILDING AREA = 9,100 SF 12. CONTRACTOR SHALL. INSPECT AND MAINTAIN AS NEEDED ALL EROSION STORAGE AREA = 750 SF REGO SHADING - i CANOPY TREE EVERY 2000 SF CONTROL ES ON A WEEKLY BASIS AND AFTER EACH MAJOR GROSS RETAIL AREA 8,350 SF I SHRUB EVERY 500 SF ENT. STORM NERD. FAILURE TO KEEP EROSION CONTROL DEVICES IN GO00 REQUIRED PARKING ® 1/200 SF GROSS FLOOR AREA = 42 ORDER MAY RESULT: IN THE ISSUANCE OF A STOP WORK REGULAR SPACES PROVIDED =42 24,770f2000 = 12 CANOPY TREES REQ'D ORDER ADA SPACES 0 1 PER 25 REGULAR SPACES = 2 24,770j500 = 50 SHRUBS REOO TOTAL PARKING SPACES PROVIDED = 44 13, ANY FIJL BROUGHT ON SITE SHALL EE: FROM AN APPROVED SITE/MINE, 5, SITE IS LOCATED IN FLOOD HAZARD ZONE "AE(52j-, SHADED "X AND LANDSCAPE ISLANDS: 1. ISLAND AND i CANOPY TREE PER EVERY 10 PARKING SPACES ANY M.ATF.RIAL. REMOVED FROM THE SITE SHALL BE DISPOSED OF IN A r "X" AS SHOWN ON F.I.R.M. PANEL 3720891300J, DATED OCTOBER 5, SINGLE APPROVED LOCATION. 2004. 44 SPACES/ 10 = 5 ISLANDS RE-O D 14. DISTURBED -REA 411.1 NOT EXCEED 2 ACRES, 5, THIS IS NOT A BOUNDARY SURVEY. BOUNDARY LIMITS SHOWN TAKEN TOTAL TREES REQUIRED = 2. SA-UTli7N:S F'ROI%1 THE E:SRO JNP UP Hyman & Robey, PC 150 US Hwy 158 E, PO Box 339 Camden, NC 27921 (252 ) 338-2913 1_M) 338-5552 fax wIAr v.hyr, amobey.com License C-0598 :vINc7 y q� C. R� "'11111111o0"J SITE PLAN FAMILY DOLLAR STORE. RELOCATION ' �ix0, 116 ELIZABETH CITY PASQUOTANK COUNTY NORTH CAROLINA If pl, pl, Project #: 130042 Drawing #: Drawn: JLE Checked: KDH Approved: SCR Date. 5l312013 Sheet #: 04/11 Scale: 1:20 REVISIONS: NUM. DATE DESCRIPTION 5,121i2013 DRAFTING REVISIONS UPDATED SITE DATA SHEET TITLE: GRADING, DRAINAGE AND E&S PLAN o SHEET NUMBER: C300 ( IN FEET ) 1 inch = 20 ft. VICINITY MAP NTS LN r 0 SITE DA'.A: 1. DEVELOPER: EASTERN PRIDE, INC. BARNES BOYKIN, SECRETARY 2405 W. NASH STREET, SUITE F WILSON. NC 27893 252-230-0632 2. SITE INFORMATION: PIN N 891307670525 /PORTION OF) D.B. 220, PG. 343 CITY MAP/LOT:49-E (PORTION OF) SITE AREA: 58,959 SF = 1,35 AC. ZONING: GS - GENERAL BUSINESS ADDRESS: 709 W. EHRINGHAUS ST. ;US HWY 17 BUS) 3. MINIMUM BUILDING SETBACKS: STREET = 20' ;EHRINGHAUS ST.1 SIDE = 20' 'WESTOVER ST.) REAR = 15' 4. PARKING REQUIREMENTS BUILDING AREA = 9.100 SF STORAGE AREA = 750 SF GROSS RETAIL AREA = 8,350 SF REQUIRED PARKING 0 1/200 SF GROSS FLOOR AREA = 42 REGULAR SPACES PROVIDED =42 ADA SPACES 0 1 PER 25 REGULAR SPACES = 2 TOTAL PARKING SPACES PROVIDED = 44 5, SITE IS LOCATED IN FLOOD HAZARD ZONE "AE(5.2)", SHADED "X" AND "X" AS SHOWN ON F.I.R.M. PANEL 3720891300J, DATED OCTOBER 5, 2004. 6, THIS IS NOT A BOUNDARY SURVEY, BOUNDARY LIMITS SHOWN TAKEN FROM PLAT ENTITLED "PLAT OF CORRECTION FOR BOYS AND GIRLS CLUB OF ELIZABETH CITY, NC", PREPARED BY BOWMAN CONSULTING GROUP, LTD., PAUL J. TOTI. PLS; DATED APRIL 18. 2013 7. THERE ARE NO WETLANDS WITMN THE PROJECT LIMITS. & SITE COVERAGE CALCULATIONS BUILDING : 9,100 SF CONCRETE: 3,198 SF ASPHALT, 24.77G SF TOTAL COVERAGE; 37,068 SF 9. LANDSCAPING REO;JIREMENTS FOR PARKIN AR AS: Sla=S_1DE 1 FER;- REO'D BUFFER = 1 CANOPY TREE PER 50 LINEAR FEET OF STREET FRONTAGE SHRUBS PLANTED 4' ON CENTER STREET FRONTAGE = 539 LF - 60' OF DRIVEWAY OR 479 LF 479/50 = 10 CANOPY TREES 479/4 = 120 SHRUBS VEHICULAR SURFACE AREA; TOTAL VEHICULAR SURFACE AREA = 24,770 SF REQ'D SHADING = 1 CANOPY TREE EVERY 2000 SF i SHRUB EVERY 500 SF 24,770/2000 = 12 CANOPY TREES REO'D 24,770,/500 = 50 SHRUBS REO'D LANDSCAPE ISLANDS: 1 ISLAND AND i CANOPY TREE PER EVERY 10 PARKING SPACES 44 SPACES/ 10 = 5 ISLANDS REQ'D TOTAL TREES REQUIRED 27 TOTAL TREES PROVIDED = 27 TOTAL SHRUBS REQUIRED = 170 TOTAL SHRUBS PROVIDED = 170 LANDSCAPED AREAS IMMEDIATELY ADJACENT TO SHRUBS SHAL'� BE MULCHED AND REMAINING AREAS SHALL BE GRASS GROUND COVER. AIL OTHER OPEN AREAS SHALL BE SEEDED OR SOD AND DABIUZED PER THE SEEDING SCHEDULE, LANDSCAPING MUST BE INSTALLED AS SHOWN ON THIS PLAN. CHANGES MUST BE APPROVED BY THE CITY OF ELIZABETH CITY DEPARTMENT OF PLANNING & COMMUNITY DEVELOPMENT PRIOR TO INSTALLATION, REQUIRED LANDSCAPING SHALL NOT BE PLANTED IN THE NCDOT RIGHT-OF-WAY. 10, ALL SIGNS SHALL REQUIRE A SIGN PERMIT, 11, ALL UTILITY CONNECTIONS SHALL CONFORM TO THE CITY OF ELIZABETH CITY STANCARDS AND SHALL BE COORDINATED WITH THE CITY OF ELIZABETH CITY PUBLIC WORKS DEPARTMENT. EXISTING UTILITY CONNECTIONS SHALL BE UTILIZED, 12, CONTRACTOR SHALL INSPECT AND MAINTAIN AS NEEDED ALL EROSION CONTROL DEVICES ON A WEEKLY BASIS AND AFTER EACH MAJOR STORM EVERT FAILURE TO KEEP EROSION CONTROL DEVICES IN GOOD WORKING OR MAY RESULT IN THE ISSUANCE OF A STOP WORK ORDER 11 ANY FILL BROUGHT ON SITE SHALL BE FROM AN APPROVED SITE /MINE. ANY MATERIAL REMOVED FROM THE SITE SHALL BE DISPOSED OF IN A SINGLE APPROVED LOCATION. 14, DISTURBED .AREA WILL NOT EXCEED 2 ACRES, NOTE: ALL COMPACTED UTILITY USING TRENCHES APPROVED TO BE BACKFIL LED OFF —SITE SELECT AND BORROW. • s• SOLUTIONS FRON1 THE GROUND UP Nyman & Robey, PC 150 US Hwy 158 E. PO Box 339 Camden, NC 27921 (252, 338-2913 (2521 338-55!>2 fax ,ww'w. hymanroaey.corn License C-0598 18550 Hgpbttl SITE PLAN #100 RELOCATION ELIZABETH CITY PASQUOTANK COUNTY NORTH CAROLINA Know what's below. Call before you dig. Project #: 130042 Drawing #: -I— S;T£PLAI;,x Drawn: JLE Checked: KDH Approved: SCR Date: 5/3/2013 Sheet * 05111 Scale: 1:20 REVISIONS: NUM, DATE DESCRIPTION 1 52112013 DRAFTING REVISIONS UPDATED SITE DATA SHEET TITLE: WATER & SEWER PLAN SHEET NUMBER: ( IN FEET ) I inch = 20 ft. 4" 2" RAD. a G 2" TYPE SF 9.5 A ASPHALT 18" oaOG0000000000000 0ocao0o0opo0a0000 6" ABC STONE BASE 6" NTS rne+..... c91`WALK CONCRETE SIDEWALK DETAIL 2" TYPE SF 9.5A ASPHALT MIX 00 CC' OO CC Oa 00 00 0 GOCGO 0_10 .t O O O a 0 0 O G 0,.,0 O o a C 0 0 0 0 0 0 a 0 0 0 C 1 a O O C 0 0O0 0 00 0 0 00a C coo 0 0 6" ABC STONE , 0 0 o a C J O a a O flO O G i0000Qa0000 COC OD Oa 0000 00 000 "fl Q C O O C a 0 a G 0 0 G L �.Ra-.f]�A O,-n9O�.On0 0�???0r`00 0S20R0 12" OFFSITE SELECT BORROW COMPACTED SUBGR.ADE 100% OF ASTM D698 ME I I 1H] I 1=1 I 1=1 I I=1 I I I 1=1 I El I 1=1 I l I _iii11111(k Ikk—+ + LIGHT DUTY ASPHALT PAVEMENT NTS 4" THICK 10' WIDE 3000 PSI CONCRETE SOEWALK -V � SLOPE 1f4" PER FOOT 4. "° 4" 's . ' ' - '— _ ,� 2" TYPE_ SF 9.5A ASPHALT a 4 6" O C GO 0aO 000000C.OQJ. \\�\\� a 6"O O 0 G OO p O OG p 000ID \�; �\\/� '.Y��\��\��\\.. ° 0 90 _ o 0 0 o 0 o 0� 0 v o `_' S 6" ABC STONE BASE COMPACTED EARTH NTS CONCRETE SIDEWALK DETAIL NTS Pf PLANT'. WO( CR+GINAL GRAI LEADER SHOULD NOT TREE PLANTING DETAIL 'LY ,ED HOSE 3LE OR ?ED WIRE NTERVALS YER TAME TER TH SAUCER EXISTING ROAD SURFACE"— 2" TYPE SF 9-5 A ASPHALT •;�,OOOOaa0000o�000oOGO00paO O00 a000000 a G o 0 0 0 0 0 a o 0 0 0 0 0 0 0 0 00 e n a 0 a c o c o a o o c o o p 0 .. O 0- O O a 0 0 C U 0 0 G C 0 0 0 0 O o GC O O O O O O C o 0 0 O C O O ? 6" ABC STONE Q a b O O G �? O O C O O O p O p^ O O O O O O O O 0 a U Q O Q" cS C 000O C^O O C O G b O C 0 0 G0,0 O O�OaO �— 2' MAX. 12" MAX SEE PLANS FOR GRADES - SUITABLE SOIL OR OFF -SITE SELECT BORROW i I PIPE �2" �. 12" PAVEMENT REPAIR DETAIL i NTS I k LINE OF BUILDING, PLANTED AREA, FENCE, ETC. I �2' #5 RE -BAR 5" ,i—CRAMS ERED EDGES .......I 2" TYPE SF 3.5A ACCESSIBLE ROUTE CROSSES jj{ IF DIMENSION 'B" IS LESS THAN 48" AND PEDESTRIANS MUST WALK ACROSS ASPHALT OVER CURB CUT AND SIDE e" THE CURB CUT, THEN SIDE FLARES 48" MIN, FLARES � + SHALL HAVE A 1:12 MAXIMUM SLOPE ,I S' 0 i O ^aeOGGGG0GO 4 OaG0ou Co oO�0c0o,r o0cnQ ^.aa0a OO oaGO0C0C0 Oa OCa 0 O00O Do Co"oOnOo O000O0000000000000 6" ABC STONE +{ co 0OnOoO 'c0 0 0 o c o a o c .000c 0 a a a eo Goaooao QO ra a o o a , oo oo 0 oa DETECTABLE WARNING DOMES SHALLapa°ooa .�. f j PIA !PWRINNIHIMAMMI a d G . G CLOSED CELL POL FOAM EXPANSION JOIN NTS JOINT SEALANT Q C 0 1 j8" RADII C ' L' a a A II 1 /2" SIUtVVALIK t)VAIWILIN MIN I — COVER 2 -0 LENGTH AND FULL WIDTH .{' - + OF OF THE RAMP FLOOR AS SHOWN, DOME BASE DIAMETER: - a°1.- -- O.45"R TO 0.70"R A 0, A ' . OBTAIN 70% CONTRAST VISIBILITY WITH pt ADJOINING SURFACE, EITHER DOME TOP DIAMETER OF NO LESS THAN A 0 � = ®- 0 0� 0 +" ,�;� LIGHT -ON -DARK OR DARK -ON -LIGHT SEQUENCE COVERING THE ENTIRE RAMP, 503; TO NO MORE �2 0 . 0 a 00 _ THAN 60% OF THE S <Op 0iv0 1 . ® ® �qQ ' A.0.9" TO 1.4" BASE DIAMETER Ktry - B=065" MIN. W 0 0 0 0 0 0 C=D.20" PRECAST CLASS "B" D=1.6" TO 2.4" CONCRETE DETECTABLE WARNING DOMES C 48" MIN. �y IDI JBI A DETECTABLE WARNING DOMES HANDICAPPED ACCESS SECTION "A -A" CURB CUT NTS ROOF DRAIN DETAIL NTS NG Cam; Itl�t , SOLUTIONS FROM THE GROUND Ufa Hyman 3+ Roney, PC 15:0 US Hwy 158 E- PO Box 33a Camden, NC 27g21 (252) 33& 2913 (252) 338ti 552 fax ww v hymanrobey,corn License C 0598 i FAMILY DOLLAR STORE El: ELIZABETH CITY PASQUOTANK COUNTY NORTH CAROLINA I t i Project #: 130042 Drawing #: 130042 - Detatls.dwg Drawn: JLE Checked: KDH Approved: SCR Date: 5/312013 Sheet #: 06,I11 Scale: NTS REVISIONS: NUM. DATE DESCRIPTION SHEET TITLE: SITE DETAILS SHEET NUMBER: NTS NTS li: _ 1 !_ ._ I _asti?`-_ I'•.: .. .I' .. .� i_L,1 2 III A. CITY OF ELIZABETH CITY 'UTILITY EASEMENT 1. A UTILITY EASEMENT FOR THE INSTALLATION AND MAINTENANCE OF PUBLIC SERVICES SUCH AS ELECTRIC, GAS, TELEPHONE AND CABLE TELEVISION SHALL BE DESIGNATED ALONG THE ROAD FRONTAGE OF ALL PROPERTY, THE WIDTH OF SUCH EASEMENT SHALL BE A MINIMUM OF TWENTY (20) FEET, 2. A UTILITY EASEMENT FOR THE INSTALLATION, MAINTENANCE AND OPERATING OF SERVICES SHALL BE DESIGNATED ALONG THE SIDES OF EACH PROPERTY WITH A MINIMUM WIDTH OF FIVE (5) FEET AND ALONG THE BACK OF EACH PROPERTY WITH A MINIMUM WIDTH OF TEN (IO) FEET. 3. THE EASEMENT SHALL BE OUTSIDE OF ALL SIDEWALKS, CURB, GUTTERS, ETC. AND BE PARALLEL AND CONTIGUOUS NTH THE APPLICABLE ROAD RIGHT-OF-WAY OR PROPERTY LINE, 4. THE INSTALLATION OF UNDERGROUND SERVICE LINES SHALL BE COORDINATED WITH THE APPROPRIATE UTILITY COMPANY, THE OWNER, CONTRACTOR, OR DEVELOPER SHALL CONTACT THE SERVICE SUPPLIER PRIOR TO THE INSTALLATION OF ANY SERVICE, TEMPORARY OR PERMANENT. THE SUPPLIER OF SAID SERVICE SHALL THEREAFTER BE DEEMED TO HAVE A DEFINITE AND PERMANENT EASEMENT ON THE PROPERTY CONSISTING OF A FIVE (5) FOOT STRIP EXTENDING TWO AND ONE HALF (2.5) FEET ON EACH SIDE OF THE SERVICE LINE. THIS EASEMENT WILL EXTEND FROM THE SERVICE EQUIPMENT TO THE SERVICE ENTRANCE AT THE STRUCTURE. THE PURPOSE OF THIS EASEMENT IS FOR THE INSTALLATION, MAINTENANCE, AND REPAIR OF SERVICE EQUIPMENT:. B. INSTALLATION 1, WATER LINES, SEWER LINES, AND STORM DRAINAGE SHALL. BE INSTALLED WITHIN THE ROAD RIGHT-OF-WAY AND SHALL COMPLY NTH ALL APPLICABLE CODES AND REQUIREMENTS OF THE STATE OF NORTH CAROLINA AND THE CITY OF ELIZABETH CITY, 2 ELECTRIC POWER, NATURAL GAS, CABLE TELEVISION, AND TELEPHONE LINES SHALL BE INSTALLED WITHIN THE TWENTY (20) FOOT EASEMENT IN ACCORDANCE WITH THE PLAN UTILITY LAYOUT AS SHOWN HEREON, WITH THE EXCEPTION OF ROAD CROSSINGS. THE OWNER, DEVELOPER, OR CONTRACTOR SHALL COORDINATE THE INSTALLATION OF THE NECESSARY ROAD CROSSINGS WITH THE UTILITY COMPANIES. ROAD CROSSINGS SHALL BE INSTALLED PRIOR TO THE COMPLETION OF THE FINAL ROAD BED. THE FINAL COMPACTED ROAD IS THE RESPONSIBILITY OF THE ROAD CONTRACTOR. 3, ALL CABLES, CONDUITS, PIPES, AND TUBING FOR THE SERVICE OF ELECTRIC POWER, NATURAL GAS, TELEPHONE, OR CABLE TELEVISION SHALL BE UNDERGROUND OR AS AGREED UPON BY THE SERVICE PROVIDER AND THE CUSTOMER, THE SERVICE EQUIPMENT SHALL BE ABOVE GROUND. SOME EXAMPLES OF SERVICE EQUIPMENT ARE AS FOLLOWS, BUT NOT LIMITED TO: A. ELECTRIC DISTRIBUTION TRANSFORMERS, SECONDARY PEDESTALS, METER PEDESTALS, SWITCH GEAR, STREET LIGHTING POLES, TRAFFIC SIGNAL POLES AND EQUIPMENT, TELEPHONE PEDESTALS, CABLE TELEVISION PEDESTALS, RADIO ANTENNAE, VALVES. B, SERVICE CONNECTIONS SUCH AS GAS AND ELECTRIC METERS, TELEPHONE AND CABLE TELEVISION TERMINATION ENCLOSURES, C. TEMPORARY EQUIPMENT FOR EMERGENCY SERVICE OR RELATED TO A CONSTRUCTION PROJECT. D. EXISTING EQUIPMENT ABOVE GROUND PRIOR TO THE NEW SUBDIVISION SHALL REMAIN ABOVE GROUND AND THE SUPPLIER HAS THE RIGHT TO MAINTAIN AND REPAIR SAID EQUIPMENT. CENTER. LINE OFF5ET-DETAIL NO PARKING LINE F 4 %S YELLOW PARKING LINE 4 /B * WHITE CENTER LINE r 4 f8„* YELLOW STOP OR TRANSVERSE BAR 24" WHITE 1D' KIP LINES WRITE IC I 40 i 2:—MIN1—SKIP LINES WHITE i 4" 6"* 2 y= ( 15' -NOTE: WHERE TWO WIDTHS ARE INDICATED, THE FIRST WIDTH APPLIES FOR A "NORMAL" WIDTH LINE. THE SECOND WIDTH APPLIES FOR A "WIDE" LINE. "WIDE" LINES ARE REQUIRED WHEN DESIGNATED IN THE PLANS, OR WHEN DIRECTED BY THE ENGINEER. TYPICAL PAVEMENT STRIPING STANDARD HANDICAPPED PARKING SIGN (TYPICAL) TO BE INSTALLED AT REQUIRED HEIGHT AND DEPRESSED SIDEWALK /f DIMENSIONAL RELATIONSHIP TO PARKING STALL. LEVEL WITH PARKING HANDICAPPED PARKING STALL (TYP.; :72 f, 1-21 i —EDGE OF SIDEWALK AS DIM'D, ON SITE I III \\ (� PARKING STALL PAVEMENT MARKINGS (TYP.; T'-i-------8.D FL WHEELCHAIR ACCESS AISLE PLAN VIEW OF PARKING STALL(S) VAN ACCESSIBLE RESERVED PARKING EDGE OF SIGN MAXIMUM PENALTY $250 o--rs CLEARANCE: SO" OUTSIDE OF PEDESTRIAN AREAS 84" WITHIN PEDESTRIAN AREAS GRADE A.D.A. STANDARD HANDICAPPED PARKING SIGN (W/ STANDARD HANDICAPPED SYMBOL) 4, ALL PROPERTY CORNERS SHALL BE LOCATED AND CLEARLY MARKED PRIOR TO THE INSTALLATION OF ANY UTILITIES. LOT NUMBERS SHALL ALSO BE SHOWN AS A. REFERENCE FOR THE PLACEMENT OF SERVICE EQUIPMENT. 5, THE UTILITY EASEMENT SHALL BE MARKED OR SUFFECIENT REFERENCE POINTS BE INSTALLED IN ORDER THAT EACH U(LITY WILL BE CAPABLE OF DETERMINING THEIR ASSIGNED SPACE WITH THE EASEMENT. C. ENCROACHMENTS: 1. LAWNS AND LANDSCAPING SHALL BE PERMITTED ON THE EASEMENTS, LANDSCAPING SHALL CONSIST ONLY OF LOW GROWING PLANTS OR ORNAMENTAL SHRUBBERY. TREES THAT ARE EXPECTED TO GROW TO A HEIGHT: OF MORE THAN SIX (6) FEET ARE NOT PERMITTED, TREES OR VEGETATION REQUIRING HEAVY MECHANICAL EQUIPMENT TO INSTALL SHALL NOT BE PERMITTED. THE UTILITY COM.ANIES SHALL NOT BE HELD RESPONSIVLE FOR DAMAGE TO LAWNS OR LANDSCAPING ON THIS EASEMENT DURING NORMAL MAINENANCE OR EMERGENCY SERVICE RESTORATION, 2. NO BUILDING, STRUCTURE OR PART THEREOF SHALL ENCROACH UPON THE UTILITY EASEMENT. 3, NO OFF STREET PARKING AREAS OF PAVEMENT OR CONCRETE SHALL BE PERMITTED ON THE UTILITY EASEMENT WITHOUT PRIOR WRITTEN APPROVAL OF ALL 'UTILITY COMPANIES THAT WILL UTILIZE THE EASEMENT. 4. THE EASEMENT SHALL NOT BE OBSTRUCTED IN ANY WAY AS WITH THE STORAGE OR STOCK PILING OF MATERIALS SUCH AS DIRT:, GRAVEL, STONE, ETC. 5, NO TREES, SHRUBBERY, OR VEGETATION OF .ANY KIND SHALL BE ALLOWED WITHIN A TEN (10) FOOT RADIUS OF ANY SERVICE EQUIPMENT- D, GENERAL 1, THE OWNER OF EACH LOT SHALL BE RESPONSIBLE FOR THE PROTECTION OF THE UNDERGROUND FACILITIES LOCATED INSIDE THE EASEMENT ON HIS PROPERTY_ THEY SHALL. PREVENT ANY SUBSTANTIAL CHANGE OF GRADE OR ELEVATION AND CONSTRUCTION OF ANY KIND THAT MAY DAMAGE THE UTILITIES WITHIN THE EASEMENT, 2. DAMAGE CAUSED BY THE NEGLIGENCE OF THE OWNER OR HIS AGENTS SHALL BE THE RESPONSIBILITY OF THE OWNER. HE SHALL PAY FOR THE REPAIR, REPLACEMENT, OR RELOCATION OF THE DAMAGED FACILITY. 3, EACH UTILITY COMPANY SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF THEIR UNDERGROUND FACILITY. 4, EACH UTILITY COMPANY THROUGH IT'S EMPLOYEES, CONTRACTORS, OR AGENTS SHALL AT ANY AND ALL T€MES HAVE ACCESS TO THE EAEMENTS FOR THE PURPOSE OF INSPECTING, INSTALLING, REMOVING, REPAIRING, OR REPLACING THEIR FACILITY OR ANY PROTION THEROF, 5, THE FINALLY APPROVED PLAT SHALL SHOW ALL EASEMENTS AND SHALL INCLUDE A STATEMENT STIPULATING RESTRICTIONS OF SAID EASEMENTS THE STTEMENT SHALL ALSO INCLUDE THE INGRESS AND EGRESS RIGHTS ASSIGNED TO THE UTILITY CONPANIES FOR ACCESS TO THEIR FACILITIES AT ALL TIMES FOR REPAIRS AND MAINTENANCE. ELECTRICAL NOTES 6' 18' 6' 3 A, ANY CHANGES TO THE PLAT SUBSEQUENT TO THE GOVENING AUTHORITY'S APPROVAL SHALL BE SUBMITTED TO THAT AUTHORITY IN WRITING AND CHANGES MADE TO THE PLAT BEFORE: RECORDING. B. THE INDIVIDUAL UTILITY COMPANY AT IT'S OPTION MAY REQUIRE THE EXECUTION OF THEIR STANDARD EASEMENT AGREEMENT, 6. THE FINALLY APPROVED PLAT SHALL BE DULY RECORDED IN THE PROPER COUNTY REGISTER 0" DEEDS OFFICE AND BE MADE .A PART OF THE LAND RECORDS OF THE APPROPRIATE TOWN OR CITY, COUNTY, AND STATE, 7. EACH UTILITY COMPANY RESERVED THE RIGHT NOT TO SUPPLY UNDERGROUND SERVICE WHEN, IN ITS JUDGEMENT, IT IS IMPRACTICAL OR CONTRARY TO SOUND OPERATING OR ENGINEERING PROCTICES TO DO SO. EXAMPLES MAY INCLUDE INUSUALLLY ROUGH TERRAIN, WET LANDS, UNUSUAL LOT LAYOUTS IN THE SUBDIVISION, LARGE QUANTITIES OF ROCK, OR UNSUITABLE DIGGING CONDITIONS. c. IT IS IMPORTANT THAT CLOSE COORDINATION EXIST BETWEEN THE DEVELOPER OR OWNER AND THE DIFFERENT UTILITIES. IT IS THE RESPONSIBILITY OF THE DEVELOPER OR OWNER TO NOTIFY AND COORDINATE THE INSTALLATION OF THE UTILITIES TO ACCOMOLISH AN ORDERLY CONSTRUCTION OF THE NEW SUBDIVISION. 9, ALL FACILITIES" SHALL BE INSTALLED AND CONSTRUCTED TO COMPLY WITH ALL APPLICABLE LOCAL, COUNTY, STATE. AND FEDERAL CODES AND REGULATIONS. SITE CONTRACTOR SHALL COORDINATE WITH CITY OF ELIZABETH CITY ELECTRICAL DEPARTMENT TO ENSURE THAT ELECTRICAL CONDUITS ARE INSTALLED PRIOR TO PLACEMENT OF ANY CURB & GUTTER, ABC STONE OR PAVEMENT > :J N (Jt W V > .- � o ca ca o � a w ROAD RIGHT OF w F WAY VARIES F PLAN UTILITY LAYOUT —.. ... 36' 4`� T �.t— 4'--►�..--- 7' -"'--- 4' —[­ S' �. 16" (TYP) DUMPSTER 72" X 72" X 72" 0 DUMPSTER 1 72" X 72" X 72" 0 1C.5' 1 11' B" SPLIT -FACED CMU 6' HIGH. PROVIDE FULL HEAD MORTAR JOINTS. FILL CORES WITH MORTAR. PROVIDE SLOPED MORTAR WASH .AT TOP AND APPLY WATER REPELLANT SEALER OVER WASH. 0 I 1 0 AREA DESIGNATED FOR RECYCLING 6" BOLLARD (TYP? a. <: - .° <- o CONTAINERS SEE DETAIL--a—b"° --a 0 6x6x 10/IO WWF 30.5' 6' THICK 3000 PSI CONCRETE SLAB 1 WOODEN j I SEMI -PRIVACY GATE (TYP) I 1 4...- '.' 8' 3'8' --- 3' - .�'---- 8 _..----'-`_.-.,,._ 3' HANDICAPPED PARKING WALKWAY PLAN VIEW & RELATED DETAILS NTS 8" CMU DUMPSTER ENCLOSURE NTS CROSS-SECTION SOLUTION; FROM 'THE GROLiN1 UP Hyman S' Robey, PC 150 US Hwy 158 E. PT.;= BOX 339 CBmden NO 27921, 252) 338-251:3 (252) H313,18.5552 fax ova w_hVn2aniobey.com License C-0598 18550 (� 't�Illti�•/il Yfetffs SITE PLAN • i 1 me z • ! RELOCATION S �� Y• L.L. 1� ELIZABETH CITY PASQUOTANK COUNTY NORTH CAROLINA Know what's belm • 8" SPLIT -FACE CMU Call befom dig. Project #: 130042 a Drawing #: 130042 - Details.dwg Drawn: JLE ° 1Y" Checked: KDH Approved: SCR a Date: 5/3/2013 Sheet #: 07111 $ Scale: NTS REVISIONS: NUM. DATE DESCRIPTION SHEET TITLE: SITE DETAILS SHEET NUMBER: C901 771 T17., CONSTRUCTION SPECIFICATIONS LAY ONE BLOCK ON EACH SIDE OF THE STRUCTURE ON ITS SIDE IN THE BOTTOM ROW TO ALLOW POOL DRAINAGE, THE BLOCK FOUNDATION SHOULD BE EXCAVATED AT LEAST 2 INCHES BELOW THE CREST OF THE STORM DRAIN. PLACE THE BOTTOM ROW OF BLOCKS AGAINST THE EDGE OF THE STORM DRAIN FOR LATERAL SUPPORT AND TO AVOID WASHOUTS WHEN OVERFLOW OCCURS. IF NEEDED, GIVE LATERAL SUPPORT TO SUBSEQUENT ROWS BY PLACING 2 X 4 WOOD STUDS THROUGH BLOCK OPENINGS. 2. CAREFULLY FIT HARDWARE CLOTH OR COMPARABLE WIRE MESH WITH 1/2-INCH OPENINGS OVER ALL BLOCK OPENINGS TO HOLD GRAVEL IN PLACE. 3. USE CLEAN GRAVEL, 3/4- TO 1/2-INCH IN DIAMETER, PLACED 2 INCHES BELOW THE TOP OF THE BLOCK ON A 2:1 SLOPE OR FLATTER AND SMOOTH IT TO .AN EVEN GRADE. NCDOT #57 WASHED STONE IS RECOMMENDED. GRAVEL FILTER - NCDOT #57 WASHED STONE CONCRETE BLOCK CONCRETE BLOCK is��sm 1.10.11111.11IIIIIIIIIII.M.1, i�um%l1m r1 Ad lEi!!IQ I iNmsssommimmel L imm 3! rMoulnisImi�i�l r�1a�r�l�ne���l ���I;+++++++,nmumamaturinii011tIINii�i1� �� SECTION VIEW BLOCK AND GRAVEL INLET PROTECTION NTS 6" X 32" W.RE FENCE CONSTRUCTION 1. CONSTRUCT THE SEDIMENT BARRIER OF STANDARD STRENGTH OR EXTRA, STRENGTH SYNTHETIC FILTER FABRICS. 2. ENSURE THAT THE HEIGHT OF THE SEDIMENT FENCE DOES NOT EXCEED 24 FILTER FABRIC INCHES ABOVE THE GROUND SURFACE. (HIGHER FENCES MAY IMPOUND VOLUMES OF WAFER SUFFICIENT TO CAUSE FAILURE OF THE STRUCTURE) BACKFILL TRENCH AND COMPACT --\ 3. CONSTRUCT THE FILTER FABRIC FROM A CON7N000S ROLL CUT TC THE LENGTH THOROUGHLY \ OF THE BARRIER 7O AVOID JO€NTS, WHEN THE JOINTS ARE NECESSARY, SECURELY '\ FASTEN THE FILTER CLOTH ONLY AT A SUPPORT POST WITH 4 FEET MINIMUM FLOW OVERLAP TO THE NEXT POST. -� 4. SUPPORT STANDARD STRENGTH FILTER FABRIC BY WIRE MESH FASTENED SECURELY TO THE UPSLOPE SIDE OF THE POSTS. EXTEND THE WIRE MESH SUPPORT \/ \/ ' TO THE BOTTOM OF THE TRENCH. FASTEN THE WIRE REINFORCEMENT, THEN THE / �• T FABRIC ON THE UPSLOPE SIDE OF THE FENCE POST, WIRE OP. PLASTIC ZIP TIES UPSLOPE SHOULD HAVE MINIMUM 50 POUND TENSILE STRENGTH 5. WHEN A WIRE MESH SUPPORT FENCE IS USED, SPACE POSTS A MAXIMUM OF 8 FEET APART. SUPPORT POSTS SHOULD BE DRIVEN SECURELY INTO THE GROUND A 8" MINIMUM MINIMUM OF 24 INCHES. 2,-(" \/ 6. EXTRA STRENGTH FILTER FABRIC WITH 6 FEET PC$? SPACING DOES NOT REQUIRE ( \/ WIRE MESH SUPPORT FENCE, SECURELY FASTEN THE FILTER FABRIC DIRECTLY TO POSTS. AIRE OR PLASTIC ZIP TIES SHOULD HAVE MINIMUM 50 POUND TENSILE STRENGTH AND A 6 MONTH UV PROTECTION RATING. 7, EXCAVATE A TRENCH APPROXIMATELY 4 INCHES WIDE AND 8 INCHES DEEP ALONG THE PROPOSED LINE OF POSTS AND UPSLOPE FROM THE BARRIER. —_ 8. PLACE 12 INCHES OF THE FABRIC ALONG THE BOTTOM SIDE OF THE TRENCH. 4. BACKFILL THE TRENCH WITH SOIL PLACED OVER THE FILTER FABRIC AND COMPACT. THOROUGH COMPACTION OF THE BACKFILL IS CRITICAL TO SILT FENCE PERFORMANCE, 10. DO NOT ATTACH FILTER FABRIC TO EXISTING TREES. aL E! NOTsSL 1. MANUFACTURED ALTERNATIVES CAN BE SUBSTITUTED UPON APPROVAL OF ENGINEER. 2. WHEN REMOVING OR MAINTAINING INLET PROTECTION, CARE SHALL BE TAKEN SC THAT THE SEDIMENT TRAPPED ON THE GEOTEXTILE FABRIC DOES NOT FALL INTO THE INLET. ANY MATERIAL FALLING INTO THE INLET SHALL BE REMOVED IMMEDIATELY. FINISHED SIZE, INCLUDING FLAP POCKETS WHERE REQUIRED, SHALL EXTEND A MINIMUM OF IC" AROUND THE PERIMETER TO FACILITATE MAINTANANCE OR REMOVAL 8" B-ACK ZIPTIE OR ALUM'.NUM TIE WITH UV �PGTEc:T1aN STEE.. FENCE POST 5' - 0.85 LB, FT. T-TYPE STEEL SILT FENCE DETAIL NTS INSTALLATION NOTES: i. TRIM EXCESS FABRIC, IN THE FLOW LINE TO WITHN 3" OF THE GRATE, 2. THE CONTRACTOR SHALL DEMONSTRATE A METHOD OF MAINTENANCE. USING A SEWN FLAP, HAND HOLDS OR OTHER METHOD TO PREVENT ACCUMULATED SEDIMENT FROM ENTERING THE INLET. 18" OF FABRIC IS TO BE 'WRAPPED AROUND WOOD .AND SECURED NTH STAPLES. THE WOOD SHALL NOT BLOCK THE ENTIRE HEIGHT OF THE CURB BOX OPENING. 'WOOD 2" X 4" EXTENDS 8" BEYOND GRATE WIDTH ON BOTH SIDES. LENGTI-i VARIES- SECURE TO GRATE. WITH WIRE OR PLASTIC TIES. GEOTEXTILE FABRIC INLET PROTECTION PVC END CAP PVC TEED I�►17T11�R1 NTS PVC ELBOW WATER SURFACE - PVC END CAP - PVC PIPE 1/2" HOLES IN UNDERSIDE DRAWDOWN DEVICE: SCH 40 PVC PIPE �& FITTINGS / r PVC VENT PIPE -� \l i 8 aFAA - 24' MAX. HEIGHT \\Ok i. INSTALL TEMPORARY GRAVEL CONSTRUCTION ENTRANCE PADS. (SEE DETAIL), 2. INSTALL EROSION CONTROL DEVICES AT SITE DISCHARGE POINTS TO PREVENT OFF SITE SEDIMENTATION, 3. PERFORM CLEARING DEMOLITION WORK, 4, CONSTRUCT DETENTION POND AND INSTALL CUTLET STRUCTURE AND SKIMMER. 5. INSTALL THE REMAINING SEDIMENT AND EROSION CONTROL PROTECTION. 6. INSTALL. STORM DRAINAGE PIPING AND STRUCTURES. 71 NSTALL THE STONE BASE AND .ASPHALT FOR THE PROPOSED PARKING. g. PROVIDE A GROUNDCOVER (TEMPORARY OR PERMANENT) ON EXPOSED SLOPES WITHIN 14 CALENDAR DAYS FROM THE LAST LAND -DISTURBING ACTIVITY FOR SLOPES 3:1 OR FLATTER AND LESS THAN 50'IN LENGTH, FOR SLOPES 4:1 OR FLATTER OF ANY LENGTH (EXCEPT: FOR PERIMETERS AND HQW ZONES), AND SLOPES NO STEEPER THAN 2:1 AND LESS THAN 10' IN LENGTH. PROVIDE A GROUNDCOVER ;TEMPORARY OR PERMANENT) ON EXPOSED SLOPES 'WITHIN 7 CALENDAR DAYS FOR SLOPES STEEPER THAN 3:1 OR SLOPES 3:1 OR FLATTER GREATER THAN SCi .N LENGTH. FOR HIGH QUALITY WATER (HWQ) ZONES, AND PERIMETER COKES, SWALES, DITCHES AND SLOPES, 5. ONCE SITE IS STABILIZED, REMOVE SEDIMENT FROM DETENTION POND, RESTORE POND TO DESIGN DEPTHS, AND REMOVE SKIMMER ASSEMBLY. 10, MONITOR .AND MANTAIN THE INSTALLED EROSION CONTROL MEASURES AND REPAIR AS NECESSARY, 11. ONCE V'EGETATICN IS FULLY ESTABLISHED, REMOVE THE CONTROL DEVICES. CONSTRUCTION SEQUENCING SCHEDULE 4C PVC PIPE SCHEDULE 40 � / \ �-- CRFIC' PLATE PVC PIPE \ ORIFICE -IA. = 1,5") =VC TEE FLEXIBLE HOSE CONNECT FLEX HOSE TO DPAW'DOWN PIPE AT OUTFLOW STRUCTURE USING HOSE CLAMP OR APPROPRIATE ADAPTER e ALL SCHEDULE 4O PvC POPE d: FITTINGS SHA'._L BE 4" MIN, C'IA. BOTTOM SURFACE FRONT VIEW SKIMMER TOP VIEW ARM AS'. "-CLOSURE WATER ENTRY UNIT THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE REQUIREMENTS OF THE EROSION AND SEDIMENT CONTROL STANDARDS AND SPECIFICATIONS OF THE DEPARTMENT OF ENVIRONMENTAL AND NATURAL RESOURCES. SOIL EROSION AND SEDIMENTATION CONTROL MEASURES SHALL BE PROVIDED ON ALL AREAS OF THE SITE WHICH ARE DISTURBED OR GRADED. PROVIDE A GROUNDCOVER (TEMPORARY OR PERMANENT) ON EXPOSED SLOPES WITHIN 14 CALENDAR DAYS FROM THE LAST LAND -DISTURBING ACTIVITY FOR SLOPES 3:1 OR FLATTER AND LESS THAN 50' IN LENGTH, FOR SLOPES 4:1 OR FLATTER OF ANY LENGTH (EXCEPT FOR PERIMETERS AND HOW ZONES), AND SLOPES NO STEEPER THAN 2:1 AND LESS TtiAN 10' IN LENGTH, PROVIDE A GROUNDCOVER (TEMPORARY OR PERMANENT) ON EXPOSED SLOPES WITHIN 7 CALENDAR DAYS FOR SLOPES STEEPER THAN 3:1 OR SLOPES 3:1 OR FLATTER GREATER THAN 50, IN LENGTH, FOR HIGH QUALITY WATER (HWQ) ZONES, .AND PERIMETER DIKES, SWALES, DITCHES AND SLOPES. THE CONTROL MEASURES SHALL BEGIN PRIOR TO ANY LAND DISTURBING ACTIVITY INCLUDING CLEARING; SHALL CONTINUE DURING CONSTRUCTION AND SHALL CONTINUE WITH THE NECESSARY MAINTENANCE UNTIL THE DISTURBED LAND IS STABILIZED. COMPLIANCE WITH LOCAL AND/OR STATE SOIL EROSION AND SEDIMENTATION CONTROL LAWS SHALL BE THE ENTIRE RESPONSIBILITY OF THE CONTRACTOR. THIS PARAGRAPH IS INTENDED TO SERVE ONLY AS A GUIDE TO THE CONTRACTOR FOR COMPLIANCE WITH SUCH LAWS. ORDERS, RULES AND REGULATIONS CONCERNING EROSION AND SEDIMENTATION CONTROL PROTECTION OF EXISTING STRUCTURES AND FACILITIES FROM SEDIMENTATION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. ITEMS TO BE PROTECTED SHALL INCLUDE, BUT ARE NOT LIMITED TO, CATCH BASINS, NATURAL WATERWAYS, DRAINAGE DITCHES. WALKS. DRIVES. ROADS. LAWNS. AND STREAMS. EROSION CONTROL MEASURES SEEDING MIXTURE. PATE 'IB/ACRE) TALL FESCUE 80 PENSACOLA BAHIAGRASS 50 SERICEA LESPEDEZA 30 KOBE LESPEDEZA 10 5MING NOTES 1. FROM SEPT. T - MAR. 1, USE UNSCARIFIED SERICEA SEED 2. ON POORLY DRAINED SITES, OMIT SERICEA AND INCREASE KOBE TO 30 LB/ACRE. 3. WHERE A NEAT APPEARANCE IS DESIRED, OMIT SERICEA AND INCREASE KOBE TO 40 LB/ACRE. NURSE PLANTS BETWEEN APRIL 15 AND AUG. 15, ADD 10 LB/ACRE GERMA.N MILLET OR 15 L8,%ACRE SUDANGRASS. PRIOR TO MAY i OR AFTER AUG. 15, ADD 25 LB/ACRE RYE (GRAIN). SEEDING DATES BEST POSSIBLE EARLY SPRING: FEB. 15-MAR. 20 FEB. 15-APR. 30 FALL: SEPT. 1-SEPT. 30 SEPT. 1-OCT. 31 SEEDING SCHEDULE SEEDBED PREPARATION THE CONTRACTOR SHALL CUT AND UISPOSE OF WEEDS OR OTHER UNACCEPTABLE GROWTH ON THE AREAS TO BE SEEDED. UNEVEN OR ROUGH AREAS SHALL BE SHAPED AND SMOOTHED TO PROVIDE FOR EFFECTIVE SEEDING AND EASE OF MOWING. THE SOIL SHALL BE SCARIFIED TO A DEPTH OF NOT LESS THAN 5 INCHES. CLODS SHALL BE BROKEN AND THE TOP 3-4 INCHES OF THE SOIL SHALL BE WORKED INTO A SEEDBED BY THE USE OF PULVERIZERS, DRAGS, CR HARROWS. THE PREPARATION OF SEEDBEDS SHALL NOT BE DONE WHEN THE SOIL IS FROZEN OR EXTREMELY WET. SOIL AMENDMENTS APPLY LIME AND FERTILIZER ACCORDING TO SOIL TESTS, OR APPLY 3,000-5,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE (USE THE LOWER RATE ON SANDY SOILS) AND %000 LB/ACRE 10-10-10 FERTILIZER. MULCHING APPLY 4,000 LB/ACRE GRAIN STRAW OR EQUIVALENT COVER OF ANOTHER SUITABLE MULCH. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, ROVING, OR BY CRIMPING WITH A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCHING TOOL. MAINTENANCE IF GROWTH IS LESS THAN FULLY ADEQUATE, REFERTILIZE IN THE SECOND YEAR, ACCORDING TO SOIL TESTS OR TOPDRESS WITH 500 LB/ACRE 10-10-10 FERTILIZER. MOW AS NEEDED WHEN SERICEA IS OMITTED THE MiXTUP•E. RESEED, FERTILIZE, ANC MULCH DAMAGED AREAS IMMEDIATELY, FROM SEEDING & MULCHING A. NCDOT #5 OR #57 OOASHED STONE SHALL BE USED. PAD TO BE 50' X 20' X 6" DEPTH MIN. B- TURNING RADIUS SUFFICIENT TO ACCOMODATE LARGE TRUCKS TO BE PROVIDED, C. ENTRANCE(S) SHALL BE LOCATED TO PROVIDE FOR MAXIMUM UTILITY BY ALL CONSTRUCTION VEHICLES, D. PAD MUST BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR DIRECT FLOW OF MUD ONTO STREETS. PERIODIC TOPDRESSING WITH STONE WILL BE NECESSARY- E. ANY MATERIAL WHICH IS TRACKED ONTO ADJACENT ROAD SHALL BE REMOVED IMMEDIATELY. F 24�LF.FF' P TEMPORARY GRAVEL CONSTRUCTION ENTRANCE NTS Hyman $ F obey, PC 115.0 Uri 4WV 158 E. ��� I C, BOX 339 C<IYiC!en. RC 27921 (2'52) 338-2CI3 (252) 3,38 55F 52 fax r==bay, hymanrobey.GGn1 License CC-05198 KIT!, 4�•. 18550 ..... ' y 4,. t+f++++"++ SITE PLAN FOR FAMILY DOLLAR STORE #100 RELOCATION M611oc `I'�WO ELIZABETH CITY PASQUOTANK COUNTY NORTH CAROLINA Know what's below. Call befom you, dig. Project #: 130042 Drawing #: 130042 - Detads.dwg Drawn: JLE Checked: KOH Approved: SCR Date: 5/3/2013 Sheet #: 08/11 Scale: NTS REVISIONS: NUM. DATE DESCRIPTION SHEET TITLE: EROSION CONTROL DETAILS SHEET NUMBER: NTS EXCELSIOR MATTING 12' AMENDED SOIL 30" TYP SET PLANT AT ORIGINAL DEPTH ll4l 1Iii 1s` t LARGE PLUGS I, I( (4.9a cuslG ) ' / INCHES} AMMEND SOIL AS SPECIFIED PLANTING NTS EXISTING SOIL SHALLOW LAND PLANTS BOTANICAL COMMON CL CHASAMANTHIUM LATIFOLIUM RIVER OATS CC CONOCLINiUM COELESTINUM WILD AGERATUM HC HIBISCUS ARNOTTAINUS WHITE ROSEMALLOW SG SACCHARUM GIGANTEUMAND ALLIES PLUMGRASSES LC LOBELIA CARD€NALIS CARDINAL FLOWER SHALLOW' WATER PLANTS BOTANICAL COMMON AS ACORUS AMERICANUS SWEET FLAG it IB IRIS VIRGINICA BLUE FLAG 'IRIS V PP PONTEDERIA CORDATA PICKEREL WEED Sc SAURURUS CERNUUS LIZARD'S TAIL SB SPARGAN!UM AMERICANUM BUR-REDD PLANT SCHEDULE —10' —iC' (?) €--CC (1) I -AS (7) E r!B (7) 1 3:1 FINISHED SUBGRADE S WAYER VEGETATION FOR WE7 15TH. AT NO TIME SHOULD SHALLOW FOR PERMANENT SHALLOW WATER ZONE DETENTION BASINS WATER PLANTS BE INSTALLED BETWEEN (0"-6" BELOW NORMAL POOL) THE THE CONTRACTOR SHALL INSTALL VEGETATION OCTOBER 1ST .AND MARCH IST. A PARTIAL FOLLOWING MAY BE USED AS IN THE SPECIFIED ZONES FOR WET DETENTION CERTIFICATION CAN BE FILED WITH NCDENR SUBSTITUT'ONS BASINS. THE HYDROLOGIC ZONES OF WITHOUT INSTAIi ATaON OF THE SHALLOW • CLADIUM JAMAICENS-t (SAWGRASS) IMPORTANCE FOR A WET BASIN CONSIST OF WATER PLANTS TO INSURE THAT THEY .ARE THE UPLAND AND THE TEN FOOT WIDE PLANTED AT THE PROPER TIMES. SEE - ECHiNODORUS SUBCORDATUM VEGETATED SHELF THAT IS CENTERED ON THE ACCEPTABLE RECOMMENDED SPECIES LIST (CREEPING B RHEA€)) PERMANENT POOL ELEVATION, THE UPLAND BELOW, THE OPTIMAL DATES FOR IS THE AREA ABOVE THE VEGETATED SHELF INSTALLATION OF SHALLOW LAND - PELTANDRA VIRGINICA (ARROW ARUM) THAT INTENDED TO RECEIVE LITTLE OR NO PLANTINGS IS BETWEEN APRIL 1ST .AND • SAGITTARIA IANCIFOLIA (BULLTONGUE) INUNDATION, THE VEGETATED SHELF IS AUGUST 3757 HOWEVER, SHALLOW LAND BROKEN INTO TWO DISTINCT REGIONS: 1) PLANTINGS CAN BE INSTALLED THROUGHOUT THE YEAR, SEE ACCEPTABLE • SAGITTARIA LATIFOLIA (DUCK POTATO) THE CONSTANTLY INUNDATED SHALLOW WATER RECOMMENDED SPECIES UST BELOW, ZONE (0' TO 6" BELOW NORMAL POOL), AND • SCHOENPLECTUS TABERNAEMONT,ANi 2) THE SHALLOW LAND OR TEMPORARILY .PLANTS SHALL INSTALLED IN BEINS (SOFTSTEM BULRUSH) INUNDATED ZONE (0` TO 6" ABOVE NORMAL CO ACCORDANCE WITH THE PERENNIAL • SCIRPUS AMERICANUS AND ALLIES PLANTING DETAIL, PLANT SCHEDULE AND POOL), TYPICAL PLANTING LAYOUT PROVIDED. IF (THREE -SQUARE) SOIL PREPARATION THE SPECIES SPECIFICALLY CALLED FOR IN • ZIZANIOPSIS MILIACEA (WATER MILLET) THE PLANT SCHEDULE ARE NOT AVAILABLE, i.THE CONTRACTOR SHALL OVER -EXCAVATE THE FOLLOWING ARE ACCEPTABLE THE UPLAND AREA BY 6" AND THE RECOMMENDED SPECIES. 3 T A SLOW RELEASE FERTILIZER O VEGETATED SHELF AREA BY 12". .APPLY FOR PERMANENT SHALLOW LAND ZONES EACH PLANT AS IT IS INSTALLED. DO NOT 2, THE UPLAND AREA SHALL BE BROUGHT TO O"-8" ABOVE NORMAL POOL) THE BROADCAST FERTILIZERS OR FERTILIZE GRADE PLACEMENT DI 6" TOPSOIL FOLLOWING MAY BE USED AS AFTER INSTALLATION IN THE AREA OF THE AMENDEDD PER THE SEEDING MULCHING T SUBSTITUTIONS: 6AR VEGETATED SHELF. SLOW RELEASE SPECIFICATIONS PROVIDED. WHEN PLACING FERTILIZERS SHOULD FEED PLANTINGS FOR FERTILIZER, CARE SHALL BE USED TO LIMIT - CAREX ALBOLUTESCENS, CRINITA, A MINIMUM OF 8-9 MONTHS, 12-14 PLACEMENT TO THE UPLAND AREA, SOD LUPULIN,A, LURIDA, AND TRiBULOiDES MONTHS IS PREFERRED. A 17-5-11 SHALL BE 'rdSTALLED ON THE UPLAND • E GLABRA (WHITE IS RECOMMENDED, BUT CAN SLOPE, TURTLE URTLEHEAD) tN2FORMULA VARY, PHOSPHUS CONTENT SHALL BE 3. THE VEGETATED SHELF SHALL BE LESS THAN 10 BROUGHT TO GRADE BY PLACEMENT OF 12" • ASCLEP!AS INCARNATA 'ICE BALLET" AMEN➢ED SO!!, SOIL SHALL BE AMENDED {ICE BAILEY SWAMP MILKWEED) AND TESTED 70 VERIFY THAT SOIL PH i6 EUPATORIUM FiSTULOSt1M (JOB EYE OWN R MAINTENANCE BETWEEN 5,5 AND 6.5 WITH A MINIMUM OF WEED) 1, THE PROPERTY OWNER SHALL INSURE THAT 5-70% ORGANIC MATTER, SOIL PH CAN BE THE WET DETENTION BASIN i6 MAINTAINED INCREASED BY ADDING LIME OR DECREASED • HELIANTHUS ANGUSTIFOLIUS (SWAMP ACCORDING TO THE OPERATION AND BY ADDING IRON SULFITE. COMPOST CAN SUNFLOWER) MAINTENANCE AGREEMENT FILED WITH BE ADDED TO INCREASE ORGANIC MATTER. NCDENR, TO INSURE THE SURVIVABILITY OF USE OF PEAT MOSS IS NOT RECOMMENDED_ • HIBISCUS COCCINEUS AND THE WETLAND VEGETATION, SPECIAL TESTING CAN USUALLY BE PERFORMED MOSCHEUTUS (ROSE MALLOWS) ATTENTION SHOULD BE PAID TO THE THROUGH THE LOCAL COOPERATIVE . JUNCUS EFFUSUS AND CORIACEOUS OUTFLOW STRUCTURE AND DRAWDOv'N EXTENSION OFFICE. (RUCHES) ORIFICE_ CLOGGING OF THESE DEVICES WILL 4.IMMED€A7ELY UPON COMPLETION OF CAUSE WATER SURFACE ELEVATIONS TO BE GRADING ACTIVITIES, INSTALL EXCELSIOR • KOSTELETSKYA MRGINICA (SEASHORE ELEVATED FOR EXTENDED PERIODS OF TIME EROSION CONTROL MATTING AND MALLOW) CAUSING INUNDATION LEVELS THAT ARE PLANTINGS. IF SITE IS NOT COMPLETELY IF LOBELIA ELflNGATA (CARDINAL UNACCEPTABLE FOR THE SPECIFIED PLANTS, STABILIZED, INSTALL SILT FENCE AROUND FLOWERS' 2-WEEDING SHALL TAKE PLACE WITHIN THE UPLAND PERIMETER AS NECESSARY TO FIRST TWO YEARS TO ASSURE THE BASIN PROTECT THE POND FROM RUNOFF FROM SCIRPUS CYERINUS (WOOLGRASS) ISN'T OVERRUN BY SUCH UNDESIRABLE UNSTABILIZED AREAS. • PYCNANTHEMUM TENUIFOLIUM VEGETATION AS CATTAILS. e ANT INSTgu ATIQN (NARROWLEAVED MOUNTAINMINIj 3.FOR TWO YEARS AFTER PLANTING. DURING I,PLANTS SHALL BE INSTALLED WITHIN 14 . RHYNCHOSPORA COLORATA AND THE OPTIMAL PLANTING SEASON OF APRIL DAYS OF COMPLETION OF GRADING ALLIES (WHITE -TOP SEDGE) 1ST AND JULY 15TH, ANY PLANT THAT DID ACTIVITIES WHEN PLANTING DATES NOT SURVIVE THE PREVIOUS WINTER SHALL CORRESPOND. FOR BEST RESULTS, VERONIA NOVEBORCENSIS (COMMON BE REPLACED, SHALLOW WATER PLANTINGS SHOULD BE IRONWEED) INSTALLED BETWEEN APRIL 1ST AND XULY 50'TYP--------- C (7) PLC (?) r`M ('; IRE, v T-SC (7} r5B t', 7) 2�������� 5��' Typ 2,5, v+• ...-w. q -'^-€ ,.. -+�,... -.,ta,.t -a,... \ ,;tA.li�-VV'iv:rtY v1,V�Io. / �Ar� iAr} �Ar \Ar -ems VEGETATED SHELF '10:11 2,s NORMAL POOL -- ELEVATION 3:t CONTOURS -/ 0 3:1 STORM WATER CONTROL BASIN TYPICAL PLANTING LAYOUT NIS WET DETENTION BASIN PLANTING DETAIL REPEAT AROUND BASIN PERIMETER WITH 10' BREAKS AT BULKHEADS AND BASIN ACCESS POINTS UPLAND ZONE SHALLOW LAND ZONE (0"-6" x ABOVE NORMAL POOL) SHALLOW WATER ZONE (0"-6" BELOW NORMAL POOL) DEEP POOL ZONE i -........ 4.. t6"A""—� GF,NERAL NO��. _ T KNOCKOUT BOX DESIGN SPECIFICATIONS CONFORM TO LATEST ASTM C913 SPECIFICATIONS FOR "PRECAST o CONCRETE WATER AND WASTEWATER iO STRUCTURES." j 2. CONCRETE COMPRESSIVE STRENGTH _ 4,000 PSI MIN, AT 28 DAYS, 3, STEEL REINFORCING CONFORMS TO REQUIREMENTS OF ASTM C890 E SPECIFICATIONS FOR STRUCTURAL DESIGN PAN VIEW LOADING FOR WATER AND WASTEWATER STRUCTURES AND UTILIZES GRADE 60 REBAR CONFORMING TO REQUIREMENTS OF ASTM A615 OR WINE CONFORMING TO REQUIREMENTS OF ASTM A185 OR BOTH 1$" 4. CONCRETE DESIGNED FOR H-20-44 t6" ""I) CAST -IN CB-18"XI8" LOADING, FRAME & GRATE PIPE PENETRATION & JOINT II _ -f CONNECTIONS TO BE .AS PER JOB SEE PLANS REQUIREMENTS. PIPE TO BE INSTALLED FOR BY CONTRACTOR AS PER JOB CULVERT i REQUIREMENTS FOR SPECIFIED SIZE o CONNECTIONS_ wl 6. JOINTS TO BE SEALED WITH PERFORMED N BUTYL RUBBER SEALANT, I l — a t t SMALL DROP INLET ` FC,T,0 TWO I_;,,,YERS ix8'a STAGGERED SHEETING TO FITEND TWO FEET BELL:: BOTTOM �iipYR=5,19 6" SCH 40 PVC PIPE FEMALE ADAPTER & --� 'HREADED PLUG l PERMANENT -,ATFR SURFACE ELEV. = 35= 6" SCH 40 PVC TEE- -"---ADED PLUG WITH 9 Di A, HOLE DRi_-ED THROUGH ;H SHALL BE CAPPED OR P U GED UNTIL SITE IS STADLIZED AND POND RES .ORED TO DESIGN DEPT•i% N TS "06' TREATED PILINGS (6' O.C.) 4x6 WHALER TWO LAYERS ix8'S STAGGERED INSTALL PILING TO FULL 16' DEPTH. DRIVE UNTIL UNTIL TOP ELEVATION MATCHES DESIGN. BOTTOM ELEV, 16' BELOW TOP INLET ELEV. = 3,00 CLASS B STONE COMPLETELY SURROUNDS RISER- im)t I IH j I Yr) NTS INLET ELEV. 6" SCH 40 t'VC (LENGTH AS REQUIRI - 20"X20"X3" THICK CONCRETE PAD 4 RIM ELEV.- (SEE PLANS) _R T BULKHEAD DETAIL NTS BARREL 12" CMP INVERT 3.50 TO 8" i D,L F. & G. _ #24364 BY GENERAL FOUNDRY;-.EAE (OR .APPROVED EQUAL) 2.a :y ROB SGLUTF IONS FROM THE G:ROUiNO UP Hyman & Roney, PC 150 US Hvvy 158 E. PO Box `139 NOTE: ALL MATERIAL AND INSTALLATION TO MEET Camden, NC 27921 MIN. SPECIFICATIONS OF (252) 338-2913 NCDOT " STANDARD SPECIFICATIONS FOR (252) 338-5552 fax ROADS AND STRUCTURES", LATEST EDITION. tvWw,hymanrobey.com License C-0598 DA, STEPS FOR INSIDE DEPTH GREATER THAN 4' ytiYt.Wa(JfjJl — INSIDE DIMENSIONS: O*`'•'/ 0(X�'�.� SHALL BE EQUAL TO THE LARGEST CULVERT DIAM_ PLUS 16" IN EACH DIM. c ; PRECAST CONCRETE AL 5--, 18550 �. —SET CULVERT FLUSH INSIDE WALL �: •''�`Cf N6<,t!1• 4,WITH SEE PLANS FOR CULVERT TYPE & sF tit �l 44r......... • ��! JJJhJIC. l, itt�l���' SITE PLAN 3000 PSI CONCRETE FOOTING FOR W/ 6x6XI0/10 WWM -COMPACT SUBGRADE TO 95% OF ASTM D 698 _ 1 �PL CEDE MIDCOLLARS TO WAY BETWEEN E STRUCTURES AND SPACED �#57 WASHED STONE 18" APART 1/2" 0 ROUND DRAWDOWN DEVICE- PRIME WITH CLEAN METAL BARS 3' O,C. SCH 40. PVC PIPE PRIME & PAINT WITH 2 PART -r 1/4" X 6" FLAT PLAT & FITTINGS BLACK EPDXY (TYR) AE / SEE INSET A 3 2" NTS A-w4 `,.-_DRAWDOWN DEVICE 19" WEIR ELEV. 4,40 4" MIN. 12' CMP INV. ELEV•. 3.Do SECTION A. -A \ CONCRETE BOTTOM AND TOP OF SRUCTURE SHALL BE REINFORCED WITH #4 REINFORCEMENT BARS 8" OC. EACH WAY. REINFORCEMENT BARS SHALL NOT BE PLACED CLOSER THAN 3" TO ANY EXPOSED EDGE OF CONCRETE, WALLS MAY BE CONSTRUCTED WITH 4" X 8" X 16' SOLID CMU'S OR CAST IN PLACE CONCRETE. #100 RELOCATION \1) ELIZABETH CITY PASQUOTANK COUNTY NORTH CAROLINA 7Jay, 17,1E C Project # 130042 Drawing #: 130042 - Details dwg' Drawn: JLE Checked: KDH Approved: SCR Date: 5/3/2013 Sheet #: 09111 Scale: NTS REVISIONS: NUM. DATE DESCRIPTION 1 5'21-!2013 ADDED TRENCH DETAIL : MOD. OUTFLOWGRADES SHEET TITLE: STORMWATER DETAILS SHEET NUMBER: HYMAN ROBEYN 3, 1 10'.1 gL P SEE WET DETENTION BASIN PLANTING DETAIL FOR PLANTING OF VEGETATIVE SHELF 5' ABOVE PERM. POOL -� PERMANENT POOL ELEV. = 3.50 �?F-r 3� ll ELEV. _ -2.00 t1SEDIMENT STORAGE ELEV. = -3.00 1 POND BOTTOM i WET BASIN CROSS SECTION NTS FINISHED GRA E VEGETATED SHELF 5' BELOW PERM. POOL. INLET SOLUTIONS f-IZOM THE GROUND UP Hyman & Robey. PC 15' WIDE , 150 US Hwy 158 E. VEGETATED SHELF 1 BULKHEAD PO BOX 330 LBAFFLE WALL RIP RAP PAD PERMANENT � Camden, NC 2t'921 FINISHED �t 20' CLASS B EROSION WATER SURFACE 1 252 338-2913 GRADE 1 �TONTROL STONE ELEV. = 3.50 / t252a 33b-5552 fax t WEIR ACROSS END TOP CONTROL T 3.70 �WE FOREBAY AREA 1 wrvw.hyrnanrobey.Gom 3 - — License C-0598 ELEV. 0,00 1' SEDIMENT STORAGE 01/V i' SEDIMENT STORAGE BOTTOM ELEV. = -1,00 CLASS B EROSION CONTROL STONE t11\N,\I BOTTOM ELEV. = --3.00 FOREBAY AREA CROSS SECTION NTS WET DETENTION BASIN LAYOUT 1„ = 10' 18550 = �..4e uau�i�� SITE PLAN iJ #100 RELOCATION t ELIZABETH CITY PASQUOTANK COUNTY NORTH CAROLINA 117"661 1 f Project * 130042 Drawing #: 130G42 - Details dwg Drawn: JLE Checked: KDH Approved: SCR Date: 5/312013 Sheet* 10111 Scale: NTS REVISIONS: NUM. DATE DESCRIPTION 1 &21"2013 DRAF TINGREVISIONS MOD OOTFLOw GRAOES SHEET TITLE: STORMWATER DETAILS SHEET NUMBER: wo I P, ;yll a< .y 22 i/2' INSTALL IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. MIN. 6" #57 STONE BEDDING UNDER WYE. CURB & GUTTER :MENT_� n SEWER CLEANOUT - SEE COMBINATION 11 AND 1/8 BEND . 3•_ MIN, SOLUTIONS FROM THE f_ ROUND UP Hyrnan & Robey. PC 150 US Hvvq 158 E. PO Box 339 Camden.NG 27921 (252) 338-2913 (252) 338-5552 fax www.hymanrobey.com License C...0598 .y9 18550 %S' F;........ C. R� !l'lllllilitit P\\ SITE PLAN FAMILY DOLLAR 0 STORE w DISTANCE VARIES z 1��12' 7,' o METER (PROVIDED BY CITY) CHECK VAL AS APPRDV EXISTING SERVICE LINE--, METER SETTER, —i 3r, +S ADAPTER FOR Cw>RESSION CONNECTION 3/A" OR I" x 18" BRASS NIPPLE 12"D x 18"L x 12"H METER BOX (CAST IRON BOX WITH CAST IRON COVER. NO READER LID ALLOWED.) LOCK WING ANGLE VALVE TAPPING SADDLE BRASS ADAPTER FOR COMPRESSION 7 CONNECTION / TYPE K COPPER. OR HDPE SDR 9—/ "ENDOPUR" TUBING SERVICE LINE CORPORATION STOP WATER MAIN 3/4" TO 1" WATER SERVICE CONNECTION DETAIL FINIS-ED SUBGRADE FINAL BACKFILI „OMPACT TO a57 STANDARD PR^CTOR (FOR TRENCHES NOT UNDER CURB OR 36" MIN. PAVEMENT, BACKFiLL USING ON-S!' TIE DIRECTLY TO � i/2' BEND •\ EXISTING LATERAL L_4" SCH 40 PVC DWV SEWER SERVICE PIPE AT 1% MIN. GRADE. (ASTM D-2665, D-1785) NOTE: SEWER SERVICE TRENCH SHALL BE COMPACTED TO 95% STANDARD PROCTOR. PVC SANITARY SEWER SERVICE NTs NTS SUITABLE SOILS. FOR —' TRENCHES UNDER STONE T, BE THOROUGHLY COMPAC _D UNDER AND ' BES'DE �E . I, j OUTSIDE DIAM OF l 6" 6" SLOPE SIDES AS NECESSARY FOR CONSTRUCTION rY WARNING TAPE ® 24-30" ABOVE TOP OF SEWER PIPE OUTSIDE OF PIPE TYPICAL SANITARY SEWER MAIN TRENCH NTS 4" THREADED" PLUG 4" THREADED FITTING BENCHED WATER & SEWER PLACEMENT NTS co FINISHED GRADE I -F�_DI CLEANOUT COVER 4" PVC AS 1ECESSARY —SANITARY TEE (SIZE PER PLANS) IN PAVEMENT OR CONCRETE • /i RELOCATION l ELIZABETH CITY PASQUOTANK COUNTY NTH FINOF ISH GR°A�eF`us" NORTH CAROLINA 4" PVC AS NECESSARY — SANITARY TEE (SIZE PER PLANS) I_N GRADED AREA SANITARY SEWER CLEAN -OUT NTS Know what's below. Call before you dig. Project #: 130042 Drawing #: 130042 • Details.dwg Drawn: JLE Checked: KDH Approved: SCR Date: 5/3/2013 Sheet #: 11 /11 Scale: NTS REVISIONS NUM. DATE DESCRIPTION 7 5121%2010 DRAFTING REVISIONS SHEET TITLE: WATER & SEWER DETAILS SHEET NUMBER: C905