Loading...
HomeMy WebLinkAboutSW6110406_COMPLIANCE_20110520STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW1�����/%� DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS ❑ HISTORICAL FILE COMPLIANCE EVALUATION INSPECTION DOC DATE D<t*o YYYYM M D D Patterson, Robert From: Adcock, Jason K CTR US USA Uason.adcock@us.army.mil] Sent: Friday, May 20, 2011 9:52 AM To: Patterson, Robert Cc: Morgan, Martha; Brown, James; Harris, Steven CIV USA IMCOM Subject: RE: Bragg project (UNCLASSIFIED) Classification: UNCLASSIFIED Caveats: NONE Thanks Robert. There are no known RCRA or UST issues in that area. v/r, Jason Adcock Storage Tank/IR/CR/MMR Program Support Environmental Compliance Branch Fort Bragg Directorate of Public Works Office: 910.432.8467 Mobile: 540.250.3194 -----Original Message ----- From: Patterson, Robert (mailto:robert.patterson(@ncdenr.gov1 Sent: Friday, May 20, 2011 9:47 AM Toi Adcock, Jason K CTR US USA Cc: Morgan, Martha Subject: RE: Bragg project (UNCLASSIFIED) It is PN 73947, Code T Adapt for Vehicle Maint. Shop Robert -----Original Message ----- From: Adcock, Jason K CTR US USA fmailto:'iason.adcock(@us.army.mill Sent: Friday, May 20, 2011 9:43 AM To: Morgan, Martha; Brown, James; Harris, Steven CIV USA IMCOM Cc; Patterson, Robert Subject: RE: Bragg project (UNCLASSIFIED) Classification: UNCLASSIFIED Caveats: NONE Marti, can you send a plan or other project reference? Though I don't believe there are any issues, Lat/Long isn't always very resolute, so I'd like to see exactly where the project is located. Thanks 1 v/ r, Jason Adcock Storage Tank/IR/CR/MMR Program Support Environmental Compliance Branch Fort Bragg Directorate of Public Works Office: 910.432.8467 Mobile: 540.250.3194 -----Original Message ----- From: Morgan, Martha fmailto:martha.morgan(@ncdenr.govl Sent: Friday, May 20, 2011 9:06 AM To: Adcock, Jason K CTR US USA; Brown, James; Harris, Steven CIV USA IMCOM Cc: Patterson, Robert Subject: FW: Bragg project Hey Jason, Can you take a look at this location and see if we have any regulated units (SWMU's or USTs) or known groundwater contamination in this location? Thanks! Marti From: Patterson, Robert Sent: Tuesday, May 17, 2011 2:44 PM To: Morgan, Martha Subject: Bragg project Marti, I'm reviewing one on the NE corner of Blackjack St. and Tapline Rd. Lat 35008' 55''N Long 78057'44 ''W Any issues with this area? The demo plan has no mention of O/W separators or monitoring wells. 3 J Patterson, Robert From: Sent: To: Cc: Subject: Tracking: Joshua, Patterson, Robert Friday, May 06, 2011 10:09 AM 'j h u rst@clarknexsen. com' Lawyer, Mike; 'lee.p.ward@us.army.mil'; 'jennings.c.lantz@us.army.mil' SW6110406 - Additional Information Request - Code T Adapt Building for Vehicle Maint. Shop - PN73947 Recipient 'j h u rst@clarknexsen. com' Lawyer, Mike 'lee. p.ward@us.army. mil' 'j e n n i n g s. c. I a n tz@ u s. a rm y, m i I' Delivery Delivered: 5/6/2011 10:09 AM I have reviewed the application, received on April 26, 2011, for the subject project. There are a few items that still need to be addressed. Please provide the following additional information: 11. Supporting calculations need to be provided for showing the minimum required treatment volume using the Simple Method; and the infiltration trench volume provided and drawdown time. 2. The existing vs. proposed BUA is confusing as presented. Please provide a table showing existing BUA, existing BUA to be removed, existing BUA to remain, new BUA added, and the total post -construction BUA. Also, the table in Section IV.10 of SWU-101 appears to incorrectly show that there is zero existing BUA. 3. The narrative states the volume provided in the infiltration trench is 18,541cf, but the supplement form states it is 17,141cf. Please make these consistent. 4. The overflow elevation is show on the plans and calculations to be 319.5. However, this elevation appears to be incorrectly stated as 319.0 on the supplement form. 5. We typically require the infiltration rate be determined using a method like a double -ring infiltrometer or Amoozemeter. These constant head methods yield more accurate infiltration rates. 6. Regarding Al/C-508: a. The full plan view layout detail of the infiltration trench needs to be provided so that the contractor knows the number of pipes, pipe lengths, and the total length and width. b. Note 2 needs to be revised or removed. Any modification to the infiltration trench on the plans will require approval by DWq prior to installation. Also, the note talks about providing the same required volume in any alternative design, but does not state what that volume is on the plans. Please note that this request for additional information is in response to a preliminary review. The requested information should be received by this Office prior to June 6, 2011, or the application will be returned as incomplete. The return of a project will necessitate resubmittal of all required items, including the application fee. If you need additional time to submit the information, please mail, fax, or email your request for a time extension to the Division at the address and fax number at the bottom of this letter. The request must indicate the date by which you expect to submit the required information. The Division is allowed 90 days from the receipt of a completed application to issue the permit. The construction of any impervious surfaces, other than a construction entrance under an approved Sedimentation Erosion Control Plan, is a violation of NCGS 143-215.1 and is subject to enforcement action pursuant to NCGS 143- 215.6A. Please reference the State assigned project number SW6110406 on all correspondence. Only plans, forms, and/or calculations that change need to be resubmitted. Any revised plans or calculations must be sealed, signed, and dated. you have any questions concerning this matter please feel free to contact me at (919) 807-6375, or robert.patterson a@ncdenr.gov. Sincerely, Robert D. Patterson, PE, Environmental Engineer NCDENR I DWQ I Stormwater Permitting 1617 Mail Service Center, Raleigh, NC 27699-1617 (Mail) 512 N. Salisbury St, Raleigh, NC 27604 1 91h Floor (Location &. I'm cos) (919) 807-6375 Phonc 1 (919) 807-6494 Fax I Robert. Pattersonnncdenr. eov Email Wcbsitr.: http'//portal.ncdenr.org/web/wq/ws/su ,A Before printing this email, please consider your budget and the environment. E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties.