Loading...
HomeMy WebLinkAboutSW3150102_APPROVED PLANS_20150306STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW� S �O DOC TYPE ❑ CURRENT PERMIT APPROVED PLANS HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOG DATE/$-0301p YYYYM M DD PROJECT INFORMATION: DEVELOPER/APPLICANT: SHELLYS WORLD, LLC RICHARD ANGINO 463'h CAROLINA CIRCLE WINSTON-SALEM, NC 27104 PHONE: (336) 499-1963 EMAIL: RICHARD@THIRDWAVEHOUSING.COM SITE LOCATION: ADJACENT TO 182 NORTH POINTE BLVD. PROPERTY OWNER: VENTURE PROPERTIES I, LLC 924 MAIN STREET NORTH WILKESBORO, NC 28659 CONTACT: AARON EDWARDS (336) 667-8000 PROPOSED LAND USE: MULTI -FAMILY APARTMENTS (RENTAL) CURRENT AND PROPOSED ZONING: R-5 MF (CITY OF STATESVILLE) PLAT BOOK: TRACT B OF PB 56, PG 69 (TO BE SUBDIVIDED) TAX MAP ID: 77374157 PIN: 4745283585 PARCEL SIZE (1 LOT): 5.281 ACRES PUBLIC STREET FRONTAGE: 910.20 FEET NO PART OF PROPERTY IS LOCATED WITHIN A 100-YEAR FLOOD PLAIN. BUILDING DATA (GENERAL, SEE ARCHITECTURAL FOR MORE INFORMATION): TYPE OF CONSTRUCTION = V-B FIRE PROTECTION SYSTEM = TYPE 3R (EXCEPT COMMUNITY CENTER) MAXIMUM HEIGHT: AREA BUILDINGS 1,2,& 3: 407" 24,900 SF (SUM OF 3 FLOORS) BUILDING 4: 30'6" 8,350 SF (SUM OF 2 FLOORS) COMMUNITY CENTER: 18'6" 2,187 SF BARRIER FREE RAMP TYPE A (TYP.) BARRIER FREE PARKING SIGN (TYP.) WOLF CREEK LANE (50 REFUSE AREA CONCRETE PAD (SEE CIVIL DETAIL) AND ENCLOSURE(SEE ARCHITECTURAL DETAIL) HEAVY DUTY ASPHALT PAVEMENT / / / / / i I I I I O I U I j I TRF ' 1 _�I I 11= ZONED R-5MF i—. EXISTING USE: VACANT IIY ' I ` y ,S87'55'53"E 90.67' S87'58'00"E r 26' ---- - — — — — — — — �gr(TIE LINE ONLY) I! } I 168.51' R I& I d 25' REAR - - YARD SETBACK r--- — - - RD-- — -I N - - 108 L)�y I ACTIVE OPEN or -I SPACE /---------------- / d 4,j / r PICNIC 5' SHELTERS BARRIER FREE RAMP TYPE B (TYP.) CB=S20'16'00"E L= 277.56' R=150.00' A=354.48' PROJECT AREA �O�T0 010 .00 DLO INIERSIA N CITY OF STATESVILLE VICINITY MAP-IREDELL COUNTY -NOT TO SCALE VENTURE PROPERTIES I, LLC REMAINDER OF TRACT B—PB 56 PG 69 6.36 ACRES +/— DEED REF: DB 1059 PG 635 *FIRE TRUCK MINIMUM TURNING RADII (TYP.) PARKING DATA: 1. ALL PARKING SPACES SHALL BE 9' X 18' (MEASURED FROM FACE OF CURBING) 2. TOTAL PARKING SPACES REQUIRED = 141 (120 BEDROOMS PLUS 1 COMMUNITY CENTER EMPLOYEE) 3. TOTAL PARKING PROVIDED: 151 (INCL. 10 ACCESSIBLE, AT LEAST ONE BEING VAN ACCESSIBLE) SIDEWA _'3: 1. ALL SIDEWALKS SHALL BE 5' WIDE EXCEPT 6.5' WIDE WHERE ADJACENT TO FRCVT BUMPER OF VEHICLES M. f_ACTIVE OPEN SPACE: ®i ' • a3,„ s� '�' 1 $'.5i F i `r 2,r��n�♦ • • ��1. 1' • • • 1 23,087 OVARRIER FREE RAMP TYPE BIiG 2. SPACE• • K*MPLAYGROUND, 3 SITTING AREAS, PICNIC SHELTER, (TYP.) Nq SIDEWALKS, POND, AND BUFFERS APPROXIMATELY 37,330 SF OPEN SPACE BY ITEM: ' ♦ ' a ° �� at ?, x� \NEW 18" CURB AND�� l�/ f'�s ' t. A 'I a' erne':§ �. ' • SITTING AREAS = 252 SF GUTTER (TYP.) 4 6\Nm� \-:,..^r, ��, i vat �v' t, s" ;,^,�o"�, ^v §3eri?= BUFFERS 21,625 SF PICNIC SHELTERS = 324 SF • u'Pc a'< 3aui . s 1. REFUSE COLLECTION AREA AND OUTDOOR MECHANICALIHEAT PUMP UNITS SHALL BE EXTEND SCONCRETE SCREENED FROM VIEW WITH FENCING. SIDEWALK AROUND AIR V, WATERSHED INFORMATION: RELEASE MANHOLE AS 1. SITE IS IN NPDES PHASE 11 STORMWATER AREA REGULATED BY NCDENIR DIVISION OF ENERGY, SHOWN. (REMOVE EXISTING MINERALS, AND LAND RESOURCES. Z. - ( (� ' 0 �� ♦ ♦ • 1 iz+fY� yP" ♦ ��AC S 3. PROPOSEDIMPERVIOUS MEMBER 4. PROPOSED IMPERVIOUS AREA AS PERCENTAGE OF TOTAL TRACT E� ZONED R-5MF EXISTING USE: SINGLE FAMILY STONEBRIDGE SUBDIVISION NEW 5' SIDEWALK REMOVE CURB AND GUTTER AND REPLACE WITH DEPRESSED CURB AND GUTTER TO MATCH OPPOSITE SIDE WHEEL CHAIR RAMP ZONED R-5MF EXISTING USE: MULTI -FAMILY (NORTH POINTE APARTMENTS) �/• / ZONED R-5MF EXISTING USE: MULTI -FAMILY RESIDENTIAL (GREYLIN RIDGE APARTMENTS) / 2�� ,�✓kl o-Fgce cop APp xOVpC¢ 9 - e iJe Il •nii �� Ir cAtrl6 '.t COndilU t ' _= lar"P r�iif k requtadbye TW9S fb.{UKd ifK e>.t r sz ��.-f lri ���r-; mli inspzcr dl:rin� +.� +str,,c::=, Flans 9n0 space and certiry swrmW&WiUIe6j15ANCAC2H 1Ut76lJr'6 � Fermi 95W D Date3�_ Jr, L ' Division "f \\ 40 0 40 80 CB=N87'34'03"W L=35.36' '� 41 GRAPHIC SCALE - FEET R=25.00' 1 "=40' A=39.28' \ PLAN LEGEND: ——°'—°'— EXISTING OVERHEAD WIRE 00L ABBREVIATIONS DIAMETER a n EXISTING SANITARY SEWER BC AGGREGATE BASE COURSE ._ SANITARY SEWER SERVICE LINE :B STORM DRAIN STRUCTURE off GRASS LINED CHANNEL - CENTERLINE — ----------------- — EXISTING WATER LINE :MP CORRUGATED METAL PIPE - :O CLEANOUT ---- — WATER LINE :ONC CONCRETE ANT CONnNUOUS E3 CATCH BASIN :Y CUBIC YARD IF _ DUCTILE IRON PIPE STONE WEIR OUTLET DC FIRE DEPARTMENT CONNECTION STONE CHECK DAM FE FINISHED FLOOR ELEVATION ® T FEET :n c uGE FRAME FABRIC INLET PROTECTION IV GATE VALVE IDPE HIGH DENSITY POLYETHYLENE GRASS -LINED PERMANENT CHANNEL H INCHES w INVERT —"—"—"—"— PERMANENT DIVERSION BERM F LINEAR FEET IAx MAraMUM __ _ B—B—B— BAFFLES IH MANHOLE IIN MINIMUM ITS NOT TO SCALE SILT FENCE IC ON CENTER - 'C POINT OF CURVATURE ...................... LIMITS OF DISTURBANCE 'I POINT OF INTERSECTION -OT POINT ON TANGENT PROPERTY LINE ;OVC POINT OF VERTICAL CURVATURE -SI POUNDS PER SQUARE INCH ITPOINT OF TANGENCY EXISTING STORM DRAIN .VC POLYVINYL CHLORIDE 'VI POINT OF VERTICAL INTERSECTION -I. """"""""""" STORM DRAIN yr - ,POINT OF. VERTICAL TANGENCY I RADIUS -. * x x FENCE ;CH SCHEDULE ID STORM DRAN PIPE EXISTING NCDOT RIGHT OF WAY IF SQUARE FEET !TA _ STATION YP - TYPICAL ------ UNDERGROUND ELECTRIC IC VERTICAL CURVE LENGTH - VWF MI -DIED WIRE FABRIC EXISTING UNDERGROUND ELECTRIC N a� U) C •.1 DO ao rl N L tU U co � O) Z o C C (`') i O p•) 0 o c rn m cp Lo L_ N 0 0 CC) Itm— �Z J W� 3u U I O N 7 0] W m O ^ U U coLLI LU 2UQ�C W Q. vIOOS J Z J J U W J Q `^ �/��/ _ V ! 0- Q�O Z (n - Lu L L I J J O� J J Lu 5 0N V V / Lu LLI '^ SHEET C1 of 9 I e Know what's below. Call before you dig. WOLF CREEK LANE (50 NOTES: 1. PROVIDE AND INSTALL SLEEVES UNDER PAVED AREAS, CURBS, AND SIDEWALKS WHERE NEEDED FOR UNDERGROUND CITY ELECTRIC SERVICE LINES. COORDINATE LOCATION WITH OWNER AND CITY. 2. IF DOMESTIC WATER SUPPLY BACKFLOW PREVENTERS ARE NOT INSTALLED INSIDE BUILDINGS AS INDICATED, THEN INSTALL AT OUTSIDE DOUBLE CHECK VALVE (DCV) ASSEMBLY AT EACH BUILDING (STANDARD DETAIL #W-12). 0 I I I I I I I I I I AN I -103.74 ZONED R-5MF OUT-98.54 I EXISTING USE: VACANT I I 108 I d _ _ 25' REAR YARD S_E_TBACK ACTIVE OPEN I SPACE d 3. ALL CITY WATER SYSTEM EXTENSIONS (INCLUDING /- — — — — — — — — — — — — — — TAPPING SLEEVE AND VALVE, FIRE HYDRANTS, / — SERVICE CONNECTIONS, AND OTHER / APPURTENANCES) SHALL CONFORM WITH CITY OF / STATESVILLE STANDARD SPECIFICATIONS AND DETAILS AND SHALL BE INSTALLED BY A N.C. 109 LICENSED UTILITY CONTRACTOR. COORDINATE ALL SUCH WORK WITH THE CITY OF STATESVILLE AND / \ r WEST CONSULTANTS, PLLC TO ENSURE PROPER / NEW 6" D.I. INSPECTIONS AND CERTIFICATIONS. 20' UTILITY WATER MAIN 4. ALL SANITARY SEWER CONNECTIONS (TAPS) TO EASEMENT CENTERED �\ r WITH ALL NEW WATER MAINS CITY SEWER SYSTEM SHALL BE INSTALLED BY A N.C. \ AND HYDRANTS LICENSED UTILITY CONTRACTOR. COORDINATE ALL SUCH WORK WITH THE CITY OF STATESVILLE TO \ ENSURE PROPER INSPECTIONS. 5. FIRE HYDRANTS SHALL BE 4-1/2" BARREL, 3-WAY TYPE WITH (2) 2-1/2" NST HOSE CONNECTIONS AND (1) 4" STORZ PUMPER CONNECTION, PAINTED �� \\ NEW 6"D.I. a SAFETY YELLOW, SET WITH CENTER OF PUMPER / �' \ \ WATER MAIN CONNECTION AT 18" ABOVE FINISH GRADE, AND PLACED AND ORIENTED AS APPROVED BY THE ti STATESVILLE FIRE AND LIFE SAFETY DIVISION. 113 $ 1 Q PM\L�> \ a % I PICNIC -d I SHELTER 1 � i a GRILL\\ / O i VENTURE PROPERTIES I, LLC REMAINDER OF TRACT B—PB 56 PG 69 6.36 ACRES +/— DEED REF: D8 1059 PG 635 CONNECT TO BLDG SEWER AT 5' FROM FOUNDATION (TYP.) a SEE INSET B / © r �• ©� I + yy I A / G / rl, \ \ZG e" / \ �J\`��F�c, IN IN NEW 6"D.I. I 6" SCH 40 PVC SANITARY SEWER SERVICE @ 1/8" PER FOOT MIN. SLOPE, 24" MIN COVER, AND CLEAN -OUT ASSEMBLIES AT 75' • INTERVALS AND AT EACH BEND (TYP.) / A A/ +/ CLEAN -OUT AT END OF TAP (TYP.) SANITARY SEWER TAP INSTALLED PER CITY `] STATESVILLE STANDARDS, SIZE AS SHOWN cP UT INCLUDING PVMT. REPAIR) - TYP. � APPROX LOCATION OF MANNOLE- PER GREMN RIDGE APARTMENTS PLANS X_\\ WATERMAI // \\ CONC PAD \\ a/a RO 0', Q SEE INSET / \ c>\0/ �t P-1 � L• \p, / \ 4 18" VERTICAL SEPARATION -WATER MAIN '51 \ \ J J / f " / OVER SEWER MAIN 4" SCH 40 PVC SANITARY SEWER SERVICE ye �� /+ \ L�� INV IN E-9 @ 1/8" PER FOOT MIN. SLOPE, 24" MIN \\ \° a '/ 4' G 00 ti 1 + + O © wv 38NUPE \ `r.0 X, COVER, AND CLEAN -OUT ASSEMBLIES AT \\ \+ « y a • oo + `*l 50' INTERVALS AND AT EACH BEND (TYP.) \ n / 1 rO APPROXIMATE LOCATION OF EXISTING 24" RAW WATER MAIN ZONED R-5MF EXISTING USE: SINGLE FAMILY STONEBRIDGE SUBDIVISION ° X QIH 53 N - .08. ra ° T- 98 a ` a ` a\ RELEASE V `• y0 EXISTING FIRE HYDRANT (TYP.) EXISTING 12" WATER MAIN ZONED R-5MF EXISTING USE: MULTI -FAMILY (NORTH POINTE APARTMENTS) MONUMENT SIGN ` PERMANENT \`�S• DETENTION POND °\ `"P o� s "9- 4 o a NV 09 \ Wv 99 a AG '•\ `a �A ` r: \ �I LO LO 1= co .H 00 ri CV L_ (1) U ++ Z (p L0 L C (7 4-r O M 7 4J qr o c U) L,s CD cc) Ln L N O O CO / / WATER SUPPLY KEY / A. 8x6 TAPPING SLEEVE, GATE VALVE & BOX, AND THRUST BLOCK. B. 6 x 6 TEE, 2 GATE VALVES & BOXES. o N ig O S 'INV IN 36HDP 4 S NV OUT �IRN E-94.3 / 8G A 4„ sue"" S 4 6 / a INV IN JBH -90 INV Wj DPE-90. S y \ / X I RM NA-- 8.21 Nl 1I.IlUT-85. / / 09 / ZONED R-5MF /'� •'' '� / EXISTING USE: MULTI -FAMILY RESIDENTIAL - (GREYLIN RIDGE APARTMENTS) "VM%OUTSE-BA zr/`/ -' '' / / y EXISTING 8" GRAVITY / SANITARY SEWER MAIN (TYP.) �1RH AIR / IN oPE— WT MWK-BAT EXISTING 8" DIP WATER MAIN (TYP.) INSET A C. FIRE HYDRANT ASSEMBLY INCLUDING 6x6 TEE, 6" GATE VALVE & BOX. w m D. DOMESTIC WATER SERVICE TAP (SADDLE, FITTINGS, AND CORPORATION STOP) IN can, ACCORDANCE WITH CITY OF STATESVILLE STANDARDS. SIZE AS INDICATED. C3 E. DOMESTIC WATER SERVICE METER ASSEMBLY (METER, YOKE, BOX, & FITTINGS) IN LU m o ACCORDANCE WITH CITY OF STATESVILLE STANDARDS. w Lu • z co o F. DOMESTIC WATER SERVICE BACKFLOW PREVENTER ASSEMBLY (SEE NOTE 2 AND DETAILS h 3 � 3Q ¢ � L w N AS APPLICABLE). I a co o o x G. DOMESTIC WATER SERVICE PIPING. USE TYPE L OR TYPE K (AS APPLICABLE) COPPER FROM MAIN TO METER, PER CITY STANDARD DETAILS. FROM METER TO CONNECTION OUTSIDE BUILDING USE SCH. 40 PVC WITH 24" MINIMUM COVER. W Q H. CONCRETE THRUST COLLAR & 6"x2" TAPPED M.J. PLUG (OR SIZE AS REQUIRED) J Z RESTRAINED TO PIPE WITH MEGALUG SERIES 1100 OR EQUAL. I J J I. 2" GATE VALVE & BOX (OR SIZE AS REQUIRED). I i (� O J. FIRE PROTECTION SUPPLY PIPING (SCH 80 PVC, AWWA C900 DR 18, DUCTILE IRON, OR W J Q GALVANIZED STEEL). SIZE AS INDICATED UNLESS OTHERWISE DETERMINED BY FIRE U PROTECTION (F.P.) CONTRACTOR/DESIGNER. STUB UP TO 12" ABOVE FINISHED FLOOR IN LOCATION AS SHOWN IN BUILDING DRAWINGS OR AS DETERMINED BY F.P. CONTRACTOR. � _ _ K. FIRE DEPARTMENT CONNECTION (FDC). SEE DETAIL.ORIENT NOZZLE TOWARD PAVED U7 0 VEHICLE TRAVEL AREAS. \ Q O O j U)W Z Q �('�� \ / W J J U � \y/ � -1 J / \ / H W W=cn E Q�cnW W ©1-- � = a • U) / cn 40 �940 80 SHEET J'RAPHIC SCALE — FEET 1"=40' INSET Y I Know what's below. Call before you dig. I I I I N I QI IIYiI q'�JI'v 0I VENTURE PROPERTIES I, LLC REMAINDER OF TRACT B-PB 56 PG 69 6.36 ACRES + - A o II i ��,�-_ _ -� I I V DEED REF: DB 1059 PG 635 TRIF - - - - - - - - - - - - \ r I' ` EROSION CONTROL CONSTRUCTION SEQUENCE AND MAINTENANCE PLAN: woLF eReeLe LANE tso Fr pusue Rrvuy' t ; !: INV OUT-- `\ \ / / ` !r-'��s�-. I i INV OUT-98.84 rl _� A. CONSTRUCTION SEQUENCE: % % RIM"data i it-�1Qrj- �1'v Iv-��\��_ ' 'I 1 v V v> 'I A / INV IN-95.]3ri r I 1 1 V A / 1. CONDUCT PRECONSTRUCTION MEETING WITH IREDELL COUNN EROSION CONTROLINSPECTOR. �' - - - - - - - \ r _ -_2. INSTALL OR IMPROVE EXISTING TEMPORARY GRAVEL CONSTRUCTION ENTRANCE AT THE ` ` 11 ACCESS POINT TO THE SITE.3. INSTALL SILT FENCING AND STONE WEIR OUTLETS.4. INSTALL OFF -SITE MEASURES TO DIRECT OFF -SITE RUNOFF INTO STREET STORM DRAIN \'1 \\'• 1 I 1 �1 I I \\-'-'"-' -� - SYSTEM (CHI, CH2, SDI). i f I 5. MODIFY EXISTING SKIMMER BASIN AND TEMPORARY SEDIMENT TRAP. 111 6. INSTALL TEMPORARY DIVERSIONS. g q ?' I i 111 l l l-------- --------- 7. REQUEST INSPECTION BY IREDELL COUNTY OF ALL INITIAL EROSION CONTROLKEEP AND MAINTAIN EXISTING MEASURES AND OBTAIN APPROVAL PRIOR TO COMMENCING OTHER SITE DISTURBANCE. t 8. PROCEED WITH GRADING, RECONSTRUCTING BERMS, DIVERSIONS, AND CHANNELS AT BERM TO PREVENT RUNOFF THE END OF EACH DAY IN ORDER TO DIRECT ALL RUNOFF INTO SEDIMENT TRAP AND o % EI IIII IIIII \ \ ie �' I IIIII 'II III IIII FROM FLOWING OFF -SITE BASIN. kl j 11 / IIII III IIIw v / �I 9. FERTILIZE, SEED, MULCH, AND MAT ALL SLOPES AS SOON AS SLOPES ARE GRADED. 10. INSTALL STORM DRAINAGE SYSTEM AND INLET AND OUTLET PROTECTION DEVICES. 11. ESTABLISH A TEMPORARY VEGETATIVE PROTECTIVE COVER WITHIN 7 DAYS OR PERMANENT GROUNDCOVER WITHIN 7 DAYS OF COMPLETION OF ANY PHASE OF I III I I�I I GRADING. 12. CONSTRUCT PERMANENT DETENTION POND AS LAST PHASE OF GRADING. DO NOT PLACEPLANTS WITHIN POND OR ON SHELF UNTIL R SK OF SEDIMENT CONTAMINATING THE PLANTS). STABILIZED SITE MUST BE ATEASNO T SS o(WITH STABLE, AS DETERMINED BY IREDELL COUNTY, PRIOR TO CONVERTING TO PERMANENT POND.-------------- B. MAINTENANCE PLAN: /� %��%% j ii '�' - -_--- / \ 1 `v REDIRECT EXISTING CHANNEL TO 1. INSPECT ALL EROSION CONTROL DEVICES WEEKLY AND AFTER EACH RUNOFF PRODUCING KEEP OFF -SITE RUNOFF FROM RAINFALL EVENT. \ / /„ y //,, , `, _ _ _ _ , - I+, I I ; ENTERING SITE. REVEGETATE ALL 2 OR REPLACE STONE WHICHREMOVE ACCUMULATED DHAS BEEN DIMENT KISPLACEDALL AOR CONTAMINATEDSURES WHEN HALF . AND REPAIR PLACE SILT FENCE AT 12" �� �V 1 lii��/�/�l i l' - '� �`� - i'I j i I I 3. AFTER VEGETATION IS WELL ESTABLISHED, REMOVE ALL TEMPORARY EROSION CONTROL INSIDE PROPERTY LINE DISTURBED AREAS OFFSITE DEVICES, GRADE THOSE AREAS SMOOTH AND RESEED. / I '� /� / � I Ilil ,ll/ SAW CUT CONCRETE PAD AT 12" SOUTHEAST OF THE PROPERTY LINE AND REMOVE CONCRETE ON THE SHELLY'S WORLD PROPERTY EXISTING TEMPORARY GRAVEL CONSTRUCTION ENTRANCE - ADD MORE STONE AND MAINTAIN UNTIL PERMANENT DRIVEWAY IS BUILT ' BOUNDARY OF V / „/%;'� I' ; '/--------- DISTURBED AREA / I I (5.6 ACRES) CH- V----------'I `� ,' a,' / \ i (14' WIDE RIP RAP) REMOVE 15" RCP '------------- V_ // ROCK INLET PROTECTION KEEP AND MAINTAIN EXISTING CHANNEL TO DIRECT ON -SITE , ''i % %'c$ �/ % (J% EXISTING RIP RAP �� \\ 'i '-�------------- '' '''�',�,' INVI DPE�'<� ` /// (REMOVE) O EO \ RUNOFF TO SKIMMER BASIN. , ,'/, IN T ''' '� REPLACE WITH CH-3 CH-4 AND ' ' /' ' r r \ �,,, i,/ ,� / / 0% LOCAiId! OF MANHOLE- � '' ,/ / \� I \ PER fYtEYl1N RIDGE APARTMENTS PLMIS CH-5 AS GRADING PROGRESSES '' 3' / .�"�/\\ ` FES-1 CH 2 \\ \ ------ > SID \IC\`\\� (8' WIDE RIP RAP) N- / �/ CONC PAD / 40 �I��a)� in TB-1 (REBUILD EACH STRAW WATTLE '/ DAY\IF DISTURBS / / CHECK DAM TYF ' / / / �1 ��� (50' MAXIMUM SP CING/%/!,� �j-J / A A ,,'�,� �- W q-91.34V/ �D-2 (REBUILD EACH �/ / h i/'/ i \5 d I4VDUT-w.19 0 \ DAY IF DISTURBED) TEMPORARY ia° V �// -;'/s ��/' / CONNECT SD-1 TO EXISTING CATCH BASIN, INSTALL FLARED I a STORM DRAIN PIPE "''' >' ✓ `' / ° END SECTION (INVERT ELEVATION 99.30) AND CONSTRUCT I ,�i/', e `'V \ %I'" 53 I /"I / \\` \ \\� \-="% ^ \\�\\\ - - -' \ �' //r ''-'"� �� •/ / ° CHANNELS CH-1 AND CH-2 TO DIRECT ALL OFF -SITE IN De a / I i `x `//%,' % '%��,� \� \\\ 1 �''�.;� �wG.Irfree6P s I ER WHERE I NV .9b / �''" �\ VA �"° °" E"`� '/ �� RUNOFF INTO SD-1. REPLACE CURB AND GUTTER 1 (1) NEW / '' % V ` v -� %� ` REMOVED FOR INSTALLATION OF SD-1. POROUS BAFFLE-,, ,AIR RELEASE V V l TOP_%.30 4 \\ �� \\-� *tY DP yo. q / \ TOP ar PIPE-e9.7 �$T•�-- / , , I j'�� ��Y, /�, / `< - ' / wMEX M INV-83.]0 \ ,', i'/, ���'� '/i//j / IN W Ba \vIh 0.N- '�jl /�/ a� VAS •- ' A NV IN O/�a38HDPE- H\ \ INVJMIT?'HI TSB-7 %' / / e✓ NOTE: THERE ARE NO SURFACE \ "X , ,' ,d �.:��, �_� � / H • ,� WATERS ON THIS SITE. vv am EXISTING TEMPORARY SEDIMENT TRAP. ' G�` ♦ �-l7-� y / RECONSTRUCT AS REQUIRED. /C',x \ % E%M 93.33 MH EXISTING SKIMMER BASIN -MODIFY AS INDICATED 'ell/ RIS- J IINV IN-83.98\ IAND MAINTAIN UNTIL SITE IS STABILIZED /\` ` NV CUT IX1T JBHD - DRE Bb.PV OUT-a3.]ei/ \ (2) EXISTING POROUS BAFFLES \ % / ° ```\ \ �,•' Ip�� /VIN 38NOPE-83.8 \O, EXISTING RIP RAP -ADD MORE RIP RAP AND // `. �� /MV MIT 36NDPE-84.1 VERIFY AND ADJUST EXISTING R I EMBANKMENT OF SKIMMER BASIN AS MAINTAIN AS REQUIRED UNTIL ci r' \ CONSTRUCTION OF PERMANENT DETENTION % •' \ I NEEDEDSHALL BE 5' WIDE MINIMUM AND POND - CREST OF WEIR ELEV. 96.50 / ' \\\ ELEV. 98.0 OR HIGHER. LENGTH OF WEIR = 40' �/ \\ DRAINS TO FOURTH \ CREEK (CLASS C) 41 \ / / IeQJH1l1 ra,ea re.}J1`t ME ttrc SL.trfi+ir3 r�r 5y � bi�na; / io3pacl duluQ caNsttUctwn• ell cr ni "t+ wah the / .lane end specs; and certify conlPitance with'he / , tornrwatar roles t 15A NCAC 2H .1008 (D)40 0 40 80 / / GRAPHIC SCALE - FEET 1 "=40' +J m a1 L U) c (D . r1 00 r1 N L N U � U) Z �p Cn � c CO ++ O CO =; -p �J- O c rn W to L N O O CO ,It I m /Z 4 WtA Z 3U V C� ^ o N V m m W 00 O ^ U L- Qm0 W W Z(� ONN Q cc ^ N W zJ _ --I J U W Q _j Ly Q O Z Q >_ W W J J � W � 0� Cn W W Q 2 � W SHEET C3 OF 9 r ° v I GRADING & EROSION CONTROL NOTES: (� I Q"I\ \ h 1. FINANCIALLY RESPONSIBLE PARTY: i ,QI I �I 'Iv vv'v N SHELLEYS WORLD, LLC v IIII 1 1 1 1 11 viI' vv v I I I i� 463-1/2 CAROLINA CIRCLE v 1 1 I I III l i WINSTON-SALEM, NC27104 vv 11 1 IIII `��`��� j 1, 110 2. TOTAL ACREAGE IN TRACT = 5.281 ACRES. 3. TOTAL DISTURBANCE AREA = 5.6 ACRES. 4. DEED REFERENCE DB 1059 PG 635. 0_ O TRF v v v v v-'_�_-, --'_ _ - ---� I v- _ _ WITH 5. ALL CLEARING DEBRIS, IF ANY, SHALL BE DISPOSED OF IN ACCORDANCE ALL STATE AND LOCAL _ _ I - - - - - - - - ' �� �, __ ORDINANCES. ___,_____,_-__,_____,_�---','-�- 6. ASSUMED SOIL CLASS B. ____ _____ ____------ _ _ _-'�l �\ �, \ \ �. _ � \ _ _ _ _ _ _, � 7. THIS PROPERTY IS NOT WITHIN THE 100-YEAR FLOOD PLAIN AND IS THEREFORE IN ZONE X. ___ l --------- i1,? ` \\ r' r 8. ALL CUT AND FILL SLOPES STEEPER THAN 4:1 SHALL BE COVERED WITH NORTH AMERICAN GREEN MATTING S 3. ALL ( ' .J�. - WOLF CREEK LANE SO FT PUBLIC l :° i EX MNII} MM-103.74 `I IIII\\` �\ \ \\ \\ `\ \ \\ \ �6NED R-5MF STAPLE PATTERN B, OR APPROVED EQUAL. ON SITE. RNI ,'®�$ I;i I ; INV OUT-98.54 14I� / I i \ / 9. A COPY OF THIS PLAN AND ITS APPROVAL CERTIFICATE SHALL BE KEPT . '--mil05j- I I I\ \\ USE: VACANT 10. A TEMPORARY GRAVEL CONSTRUCTION ENTRANCE SHALL BE PLACED AT ALL ACCESS POINTS TO THE SITE RIMM102.18 i INV IN-95.73 i I -'�� \ ,EXISTING TO PREVENT THE TRACKING OF MUD ONTO THE EXISTING STREET. ALL VEHICLES SHALL BE WASHED FREE OF % ANY LOOSE MUD BEFORE EXITING THE SITE. CTED IN ACCORDANCE WITH THE CURRENT NCDENR 11. ALL EROSION CONTROL MEASURES SHALL BE CONSTRU - - - - - - _ _ _ _ _ _ _ - _ --_ _ EROSION CONTROL MANUAL.• --- - _------'---__ 12. NO IMPORTING OR EXPORTING OF SOIL IS ANTICIPATED IN THIS PLAN. IF SUCH IS REQUIRED, A MODIFIED -- _ PLAN MUST BE SUBMITTED AND APPROVED BY IREDELL COUNTY DEVELOPMENT SERVICES. 13. PERFORM SELF -INSPECTIONS AND RECORD KEEPING AS REQUIRED BY NPDES STORMWATER PERMIT NCG I \ 115' 4 ( 010000, COPIES OF RAIN GAUGE RECORDS AND MAINTENANCE ACTIVITIES SHALL BE MADE AVAILABLE TO \ \ \ ' �' I IREDELL COUNTY PERSONNEL AT ALL TIMES. �I I I g tr5 I I I w I 41 108 I vIIII 11 l -- -- ACTFVE v `. GENERAL SITE NOTES: o r' °III SPACE ((�, IIII CH-3 1. THE EXACT LOCATION OF THE EXISTING UTILITIES SHALL BE w j 71 111 j r vv VERIFIED AND DETERMINED IN THE FIELD. ALL EXISTING --_-- - j/ o 111 IiI ilil B UTILITIES MAY NOT BE SHOWN AND SHALL BE LOCATED BY THE CONTRACTOR PRIOR TO STARTING WORK. NOTE: - - - - - 2. ALL ACCESSIBLE ROUTES SHALL BE IN COMPLIANCE WITH THE ALL CATCH BASIN INLETS SHALL BE CURRENT NORTH CAROLINA ACCESSIBILITY CODE FOR SITE _ _ - ACCESSPERTAININGTOSIDEWALKS,TRANSITIONS, CURB CUTS PROTECTED WITH HARDWARE CLOTH ', ;; I ; I \ --__ AND SLOPES. 9 AND GRAVEL (SEE DETAIL). WHEN ALL / ; ;� III ; I FLvv`� // ----- ' op 3. ALL SIDEWALKS SHALL HAVE A LONGITUDINAL SLOPE OF 5 /P OR LESS. ALL BARRIER FREE PARKING SPACES AND AISLES SHALL AREAS ARE GRAVELED OR PAVED, BE SLOPED AT 2% OR LESS IN ANY DIRECTION. ALL GRADES REPLACE HARDWARE CLOTH TYPE SHALL BE VERIFIED PRIOR TO PAVING OR PLACING CONCRETE._ 4. MAINTAIN AN "AS -BUILT" SET OF DRAWINGS. THE DRAWINGS PROTECTION WITH (SILT SACK'TYPE SHALL BE RED -LINE MARKED TO REFLECT CHANGES IN PIPELINE PROTECTION AT EACH CATCH BASIN. IG AND STRUCTURE LOCATIONS AND ELEVATIONS FROM THE �� \ \ �// �/ /' �`� `Z` ORIGINAL DRAWINGS AND GIVEN TO THE ENGINEER OR OWNER UPON COMPLETION OF THE PROJECT. SUCH RED -LINE MARKS SHALL BE BASED ON MEASUREMENTS USING A TAPE AND TRANSIT, OR BETTER. A LICENSED SURVEYOR IS NOT REQUIRED TO PERFORM THIS TASK. 5. THE EXTERIOR WATER AND SEWER SHALL CONNECT TO THE / / \ \ l661 l/ l / r 770 INTERIOR PLUMBING AT 5 FEET OUTSIDE THE FOUNDATION. 6. THE FIRE SPRINKLER LINE SHALL BE INSTALLED 12" ABOVE / - -_ FINISHED FLOOR. SEE FIRE SPRINKLER DRAWINGS FOR STUB UP ` LOCATION. / 7. ALL OTHER UTILITIES SHALL BE COORDINATED BETWEEN THE - CONTRACTOR AND THE INDIVIDUAL UTILITY SERVICE PROVIDERS.Ily SD-2 I FFE 110.50 SE 51� 510 tioN� \ , cea� - - -- CB-3 // `---- //�° ` 3 CH-4 ' / SD-5 SD-4� 6"0 HDPE DRAIN PIPE - 114 EXTEND TO DAYLIGHT 4"0 HDPE ROOF DRAIN PIPE 9 / CB-5 (CONNECT / T ALL DOWNSPOUTS / I CONC PAD / AND DISCHARGE INTO CB-7)AREA /�/ SD-9 / �G ✓ YARD INLET FFE 109.5� CB-8 i;QJv fi #3 5, EX E 9s INsE_MMjH9��(Bm // YRj� ' v 91.�4 t , ALZ FAMILY 310N ZONED R-5MF EXISTING USE: MULTI -FAMILY (NORTH POINTE APARTMENTS) I I \ \ \ 41 \ \ \ \ Ile "Ile / '9 I/s EX MH ' Yd RIM-IO�rZIS / Aw IN IN11((,WT r / / ZONED R-5MF %< 3gN EXISTING USE: MULTI -FAMILY RESIDENTIAL NV�T 36D�E- (GREYLIN RIDGE APARTMENTS) / / / RIP RAP APRON (TYP.); AT SD-7 OUTLET, EXTEND RIP RAP IN ALL STORM DIRECTIONS 9' FROM END OF PIPE. DRAINAGE GRAPHIC SCALE - FEET 111=40' TOP INVERT INVERT TYPE ELEV. IN OUT DEPTH ELEV. ELEV. FLARED END SECTION N/A N.30 M 30 WA FRAME AND GRATE 108.50 WA 105.50 3.00 FRAME AND GRATE 108.20 104.80 104.60 3.60 FRAME AND GRATE 10780 103.20 103.00 4.80 FRAME, GRATE & HOOD 105.20 N/A 102.20 3.00 FRAME AND GRATE 107.50 101,20 101.00 6,50 FRAME AND GRATE 106.20 100A0 W.90 6.30 FRAME AND GRATE 102.70 N/A 99.70 3 W FRAME, GRATE & HOOD 104,25 10177 101,75 2S0 FRAME, GRATE & HOOD 104.25 IW,00 101,93 227 STORM DRAIN PIPE SCHEDULE N0. INLET OUTLET LENGTH INV. INV. SLOPE PIPE SEE PIPE STRUCTURE STRUCTURE (FT) OUT IN)TYPE SD-1 FES1 EX CB 16 99.30 99.10 1.25% 36 HOPE SD-2 C81 CB2 70 105.50 104.80 1.00% 12 HDPE SDJ C82 CB3 70 1D4.60 103.20 2.00% 12 HDPE SDJ CS3 CBS 70 103.00 101.20 2.57% 12 HDPE $DS C34 CBS 98 102.20 101.20 1.04% 12 HDPE SD-6 C85 CBS 87 101.00 100.10 1.03% 18 HDPE SO-7 CBS PE1 109 99.90 97.00 2.66% 18 HDPE SDA C87 PE2 72 99.70 92.00 10.09% 12 HDPE SD-9 PE3 CB9 10 102.10 102.00 1.00% 15 RCP SD-10 CBS CBS 22 101.98 1D1.77 0.96% 15 RCP SD41 CBS PE4 10 101.75 101.65 1.00% 15 RCP SD-12 RISER EX JS 76 86.00 84.00 2.63% 18 RCP VENTURE PROPERTIES I, LLC REMAINDER OF TRACT B-PB 56 PG 69 6.36 ACRES +/- DEED REF: DB 1059 PG 635 STRAW WATTLE \ CHECK DAM (TYP.). II J 1 \i / I CH-3 III i I i / / I / I I a / I / 1 / / I a � / / % CH-1 APPROX LOCATION OF MANHOLE - PER GREMLIN RIDGE APARTMENTS PLANS FES-1 \ \ \ \ \ \ \ TEMPORARY SEDIMENT TRAP SCHEDULE NO. DEPTH WIDTH LENGTH WEIR LENGTH (FEET) (FEET) (FEET) (FEET) 4.0 TRAPEZOIDAL RIPRAP CHANNEL SCHEDULE BOTTOM d50 RIPRAP CHANNEL SIDE WIDTH DEPTH SIZE SLOPE NO. (HAO FEET FEET INCHES CH 1 4 6.0 1.0 18 CH 2 3 2.0 1.0 12 TEMPORARY DIVERSION SCHEDULE SHAPE: PARABOLIC LINING: GRASS PER SEEDING SPECIFICATION CHANNEL TOPWIDTH DE NO. IT, --TD1 -_ 80 TD2 4.0 R R Know what's below. Call before you dig. kl"iy�3ilVPt @tzPF' A ±=;-UfR@DS3 .�Orif? SCC FU'7-Ttt."' tir�Ufri80tS 'i 3q±llf�e vi 13 s'Y4 sWSEkar ': '' :%Rrilii�l0 luiss rewi o msttPNS NWI mr cBxigNa: I " cCY duang CilHatPUCYDt' Ci �^l:1i?}' wnh tAe r :anS and+WW4; and certify cs, n With the minwate7 F�las (15A NCAC i D ? /' )1 G 6� j P)T C / R 100 0 100 200 1" -100' ' f DA2=19,680 SF DA3=19,200 SF i , \ f 4,507 SF /= DA8=17,258 SF DA6=,DA4=3.25 SF DA5=6,134 DA7=3,300` I , DA9=8,587 SF DA11=71471 SF 02=11,337 SF , DA10=16,11 CF11 DA13=6,667 OAT=39,735 4-` (D N L_ +_± En Ln n C CD H CO `H N L -`Zro CD 4-± -1 CT 7 O c: C 0) C L. C\I O O CO qt Ln Z J WN 3 t0 V qW O O N 3 7 m M CO m m .. V W O r U Qmo W W Z O N N > - cc cc LILI - - D_TnQQ Or •-•-N PERMANENT GRASS -LINED CHANNEL SCHEDULE \ SHAPE: V-SHAPED LINING: GRASS PER SEEDING SPECIFICATION \�\ \ DA14=26,009 SF SHEET TEMPORARY LINER CHANNEL TOP WIDTH DEPTH TYPE N0. FT. FT. / `, \ \, DRAINAGE AREAS CH3 6.0 1.0 STRAW WITH NET `,\ j' / .' i 100 0 100 200 on 0 Sol I �� OF ^ CH3 6.0 1.0 STRAW WITH NET / (VM' CH5 6.6 1.1 STRAW WITH NET ' 111=100' - r r Y Y r Y Y Y Y 10'0" MIN NOTES: FILTER -DRAINAGE DIAPHRAGM: 5'0" 510" ASTM C33 SAND 1. ALL PLUGS SHALL BE ANSI Z60.1 SIZE #SP1 OR LARGER. 2. ALL WETLAND PLANTS SHALL BE ACQUIRED FROM A LOCAL NURSERY/SUPPLIER THAT REGULARLY SUPPLIES SUCH PLANTS, SUCH AS CAROLINA WETLAND SERVICES, INC. OF CHARLOTTE, NC. 3. FOLLOW TEMPORARY SEEDING SCHEDULE FOR INTERIOR OF POND AND FOREBAYS. 0 4. LANDSCAPING CONTRACTOR SHALL USE TESTING SERVICES OF THE NC DEPT. OF AGRICULTURE TO DETERMINE SOIL SUITABILITY AFTER INCORPORATING THE COMPOST LAYER AND SHALL H FURTHER AMEND THE SOILS AS RECOMMEND BY THE LOCAL 18" RCP COOPERATIVE EXTENSION AGENT OR NRCS OFFICE. SD-21 = 5. LANDSCAPING CONTRACTOR SHALL WARRANT ALL PLANTINGS FOR O 2 YEARS, REPLACING PLANTS THAT DIE DURING THAT PERIOD. PERFORATED o C GATED 24" PLASTIC PIPE FILTER DRAIN 12" 24" 12" 4110 RUGATED PLASTIC PIPE 8'X2'X2' BLOCK OF 78M STONE 4'0" FILTER DRAIN AT AROUND PERFORATED PIPE CENTERED MIN 1% MINIMUM GRADE IN THE LOWER HALF OF THE FILTER. ; TO DAYLIGHT (TO JUNCTION BOX) PLUG PIPE ENDS (TYP) \ �� BASIN AND FOREBAYS ACCESS FILTER DIAPHRAGM DETAIL ROUTE AND OTHER ENT MAINTEMOVAL NANCE � AND OTHER MAINTENANCE NOT TO SCALE Ss\ \ \ s FILTER DIAPHRAGM SPECIFICATIONS �� �ss \ \ A. INSPECTION: 12' WIDE GATE THE FILTER DIAPHRAGM SHALL BE CONSTRUCTED USING ASTM C 33 FOR FINE AGGREGATE `� ` ss\ `. (SEE DETAIL), (THE SAND USED FOR MIXING CONCRETE) UNLESS UNUSUAL SOIL CONDITIONS EXIST. IF THE SOILS DO NOT APPEAR TO BE A CATEGORY 2, THEN AN ADDITIONAL DESIGN CHECK MAY BE \ REQUIRED. \0 (C42LTI ss `� i B. PLACEMENT THE FILTER DIAPHRAGM SAND SHALL BE PLACED UNIFORMLY IN LAYERS NO GREATER THAN B AIR RELEASE V INCHES, THOROUGHLY WETTED AND THEN COMPACTED. EACH LAYER OF SAND SHALL BE 30 ♦ \� COMPACTED BY A MINIMUM OF 2 PASSES WITH A VIBRATORY PLATE COMPACTOR WEIGHING TOP TOP OF OF PIPE-86.7 �\ d 1 AT LEAST 160 POUNDS AND HAVING A CENTRIFUGAL FORCE OF 2,450 POUNDS AT A VIBRATING FREQUENCY OF NO LESS THAN 5,000 CYCLES PER MINUTE OR APPROVED EQUAL. THE SAND IN V-83.70 SHALL BE PLACED IN A MANOR TO AVOID SEGREGATION OF PARTICLE SIZES. NO FOREIGN MATERIAL SHALL BE ALLOWED TO INTERMIX OR CONTAMINATE THE FILTER. \ C. FILTER DRAIN THE FILTER DRAIN SHALL BE EXTENDED FROM THE CENTER OF THE SAND FILTER TO THE JUNCTION BOX. THE END OF THE PVC WITHIN THE FILTER SHALL BE CAPPED WITH MIRAFI 140 �\ 9Sy� s\ NC OR EQUAL. THE 4" DIA. CORRUGATED PLASTIC PIPE SHALL BE NON -PERFORATED. \ EL. 96. 00 - UPPER ORIFICE 6"SO.- EL. 94.60 - EL. 93.50 - LOWER ORIFICE 1.5"0 4"x4" PRESSURE TREATED - POST PAINTED RED UP TO SEDIMENT CLEANOUT ELEVATION 10' SHELF AT OUTLET OF FOREBAY N7 ONLY MIN. 48" HIGH SAFETY FENCE 1 12" CONCRETE TRASH RACK 99. 00 INVERT ELEVATION �86.00 18"0 RCP ON 2.63% MINIMUM SLOPE TO EXISTING JUNCTION BOX WET POND RISER DETAIL NTS EL. 93. 10 94. 00, TOP OF DAM GALVANIZED STEEL ROD 3' x 3' CONCRETE TRASH RACK (2- BOX RISER OPENINGS) WITH BAFFLE 'i GRAVEL FILL FOR I RISER ACCESS � rEL. 93.00 PLACE MINIMUM 6" LAYER OF CLAY SOIL IN 11 7 MAIN POND AND FOREBAYS UP TO THE 94.0 3 FOR 2 1 CONTOUR, UNLESS SOIL TESTING PROVES THAT � POND 1������/�����(� ON -SITE SOILS HAVE AN INFILTRATION RATE�yTyUT�jT,Yi?� OF 0.01 INCHES PER HOUR OR LESS. AT 10' i. " WIDE SHELVES, CLAY LINER SHALL BE PLACED BELOW THE COMPOST)SOIL PLANTING LAYER. OTTOM EL. BOTTOM EL. FOREBAY N7: 89.00 87.00 FOREBAY 82. 91.00 NOTES: 1. BARREL SHALL BE REINFORCED CONCRETE PIPE AS PER THE SPECIFICATIONS. ALL 1.50'0 PERMANENT GALVANIZED - JOINTS SHALL HAVE WATER -TIGHT RUBBER STEEL PIPE GROUTED INTO GASKETS. WALL OF RISER AND EXTENDED 2. THE SEDIMENT STORAGE LEVEL IS 1 FOOT 6" OUT AND SLOPED DOWN ABOVE THE BOTTOM OF THE POND AND EACH FROM RISER FOREBAY. 70' WIDE SHELF MIN. 48" HIGH (TYP) SAFETY FENCE COMPACTED FILL EMBANKMENT (DAM) 5' MIN. 70P OF DAM EL. 88.00 1 FILTER DIAPHRAGM_ L3- - - (SEE DETAIL) 18'0 RCP BARREL INSTALL RISER 12' DEEPER THAN INVERT OUT ELEVATION AND FILL WITH CONCRETE UP TO DESIGN INVERT (FOR ANTI -FLOTATION) ON 12' STONE BASE WET DETENTION POND DETAIL SECTION VIEW NTS -CONTINUES TO EXISTING STORM JUNCTION BOX (SEE PLAN) X\ _Md Deep Pool (1,075 square feet) Shallow Water (750 square feet) Shallow Land Upland I DEEP POOL PLANTINGS Zone feet & 411 linear feet of water's IN --- ---- ......... Permanent Vegetation for Wet Detention Pond _ Minimum Common Name Botanical Name Quantity Squarestem Spikerush Eleocharis Quadrangulata 134 plugs Needle Spikerush Eleocharis acicularis 134 plugs Sweet Flag Acorus americans 63 plugs Blue flag iris Iris versicolor __._..__ _. ..._,., . ,__ 63 plugs ----- Soft Rush Uuncus effusus 63 plugs Fringe Sedge Carex crnito 375 plugs Elderberry SambucusCanadensis 752plugs Centipede Eremochloa ophiuroides or N/A HIGH WATER LEVEL-2 YEAR STORM / (ELEV. 95.6) � 11 1 TOP OF PERMANENT POOL \ (ELEV. 93.5) - TYP. Eremochloa Buse W ss 4' BLACK VINYL -COATED CHAIN LINK FENCE (SEE DETAIL) /SS i �ss i / TENT STORM WATER s MENT EASEMENT AREA \ +_1 CD LO C71 LO c (00 •,I 00 r-I N L r O U rD +� z CO + O CO 0 tz c cn La CD LO L.N O O Co It V i N Z 0 J WN Z O Z CL z H Z W Q G `: \ "`SS y ss O N 'T� ' / ' / / 7 Q1 /� �r cc V- \ `� 1 r - W to `' �� �\ 1 ss / \ N ro m % 7T.\ � 6 1 a) SS \ / / ss N m !fir "~`\� i LLJ W W 2 U) N 6! GQ W Z 20 0 20 40 > U O GRAPHIC SCALE - FEET Q 0_ 1 „=20' (n Quo 4. 2.5' 10, UPLAND < ` ' W DEEP POOL SHALLOW WATER SHALLOWLAND J J \ W = > W ELEV. 95.6 'JJrrMr,ls Ig 1 " ELEV. 93.0 � \ � i':£ � . Lll (2-YEAR STORM r� +'ruh - O) } li } L,41 IRa ........ - - MAX. WATER LEVEL) YK ys rs; • '. 5 .i93iyjtkll 5 1 T ifam+i;y with tl+a l \ ELEV. 94.0 V) \\ DEmLL\ 1" OF ORGANIC COMPOST PLACE AND BLEND INTO TOP 4'OF SOIL SHEET VEGETATION ZONES - SCHEMATIC CROSS-SECTION NTS C5 OF 9 V Y Y Y Y Y Y r17- ----- ---_. _ r -1 1., GT- AGGREGATE SIZE: USE 2"-3- WASHED STONE. DIMENSIONS OF GRAVEL PAD: THICKNESS: 6" MINIMUM WIDTH: 12' MINIMUM OR FULL WIDTH AT ALL POINTS OF THE VEHICULAR ENTRANCE AND EXIT AREA, WHICHEVER IS GREATER. LENGTH: 50' MINIMUM TEMPORARY GRAVEL CONSTRUCTION ENTRANCE STEEL 'T' POSTS (1. 33 POUNDS POO FOOT) xares: EXTEND FA9flIC AND WIflE INiO EMN 1. TO DE NIAAFI 100 ON E,, ON "IFATTMN USL Y TO AIT5. AT IACH W6, SII Dole . 1Y HA 1< G9 WIPE NESN SYIPPOIII W, WIPE fErvCE. Wool z. STEEL LCIA TO BE SFT Ai A DEPTH TH r IS 24- NHH" AR"M GOOMAS LEVEL. 3. IMLU' POSTS $HALL NOT BE USED A ELITEI, TO BE SPACESCNITI B (MAXI MOM) LITERAL OIL, WtflE MESX WIIIEOf Ml-..L 5 PPOVIOE 4-FOOT WIOE OUTLETS IN FENCE EVENY SO ANO ATOF LEVI POINT IN FENCE OOTLETS SHALL 6E PFOTECTEO WITH B' THICKNESS OF SNIVEL B SILT FENCING SHALL BE PLACED IS OFF TEE OF F111 sL.A SILT FENCE DETAIL T x-SECTION AREA (A)=z'd2 ­�x'- TOP WIDTH (T)=2dz a e- TRIANGULAR W" z= d W NOTE: a ; TER FABRICMIRAFI \ 700X OR EQUAL FILTER LAYER (GRAVEL OR FABRIC) TRAPAZOIDAL RIPRAP CHANNEL 1}; rond Stabili Guzatton� Site Area Stabilization Stabilization Time Description Time Frame Frame Exceptions • Perimeter dikes, swales, ditches 7 days None and slopes • High Quality Water (HQW) 7 days None Zones If slopes are 10' or • Slopes steeper 7 days less in length and are than 3:1 not steeper than 2:1, 14 days are allowed. 7-days for slopes • Slopes 3:1 or 14 days greater than 50 feet flatter in length None • All other areas (except for with slopes flatter 14 days perimeters and than 4:1 HOW Zones * "Extensions of time may be approved by the permitting authority based on weather or other site -specific conditions that make compliance impracticable." (Section ILB(2)(b)) • Same weekly inspection requirements • Same rain gauge & inspections after 0.5" rain event • Inspections are only required during "normal business hours" • Inspection reports must be available on -site during business hours unless a site -specific exemption is approved. • Records must be kept for 3 years and available upon request. • Electronically -available records may be substituted under certain conditions. • Projects permitted under the previous permit can continue to follow the previously -permitted conditions. • Complete applications received prior to August 3, 2011 can follow conditions of approved application. • Applications received after August 2, 2011 must comply with new permit conditions. SEDIMENT BASIN BAFFLE DETAIL NTS MATERIAL NOTES: 1. WIRE FABRIC SHALL BE 14 GA., 6X6 STEEL WELDED WINE MESH. 2. BAFFLE FABRIC SHALL BE JUTE MESH, COIR FIBER OR EQUAL. 3. T-POSTS SHALL BE 1.33 LBIFT STEEL POSTS, 6' IN HEIGHT, SPACED AT 6' INTERVALS. INSTALLATION NOTES' 1. DRIVE STEEL T-FOSTS AT LEAST 24' INTO GROUND. WOODEN POSTS SHALL NOT BE USED. 2. ATTACH 6X6 WE AND FILTER FABRIC TO T-POSTS WITH WIRE STAPLES. 3. BURY WE AND FILTER FABRIC IN A MIN. B' DEEP TRENCH AND COMPACT SOIL OVER ASSEMBLY. 4. BAFFLE SPACING SHALL BE AS FOLLOWS FROM INLET TO OUTLET: INLET ZONE 35% OF BASIN LENGTH FIRST CELL - 25% OF BASIN LENGTH SECOND CELL - 25% OF BASIN LENGTH OUTLET ZONE - 15% OF BASIN LENGTH WIRE FENCE SILT FENCE WITH STEEL FENCE 14 GA. WIRE MESH POST SILT FENCE (TYP)� HARDW E WITH 14 Ga.. I--4 --I CLOTH WIRE MESH I (EYE) FILTER OF 1' I DIAMETER OF 3' FILTER WASHED STONE FM IC W, i GROUND TOP OF SILT FENCE ry MUST BE AT LEAST A\0' 1' ABOVE THE TOP OF THE WASHED STONE BURY WIflE FENCE �� BURY S' OF IC EILTEfl FA69I AND HAMWARE UPPER EDGE II w 1.1 II I II w �' w LPCLOTH IN TflENCH OF FILTER FABRIC IN TRENCH BURY WIRE FENCE FRONT VIEW FILTER FABRIC CROSS SECTION VIEW AND HARDWARE STEEL FENCE POST SET 2' APART CLOTH IN TRENCH OF 1 NON OF 8'INT0 SOLID CJ10UN0 STONE WEIR OUTLET NTS s MIN. 12- N.C.D.O. r. W57 WASHED STONE FACE -� 3600 CILFT. (ACRE 1.5' MIN 2'• 21' CROSS SECTION MIN. MIN. SIDE SLOPE - MAX. MIRAFI 100E Oi EQUAL IT A FABRIC-- 3' MIN. STONE SECTION TEMPORARY SEDIMENT TRAP NOTE: SEE PLANS FDA TRAP DIWMSIPVB Li5, CLASS B STOVE r (e50=M') Iz. "� .MIRAFI L. ON EgIAL FILTER FABRIC OVERFILL S' FOR SETTLEMENT -7 E EME B' TOP NATURAL GRXING ,Ii t Tl t01T4 -.zn • No paint or liquid wastes in stream or storm drains • Dedicated areas for demolition, construction and other wastes must be located 50' from storm drains and streams unless no reasonable alternatives available. • Earthen -material stockpiles must be located 50' from storm drains and streams unless no reasonable alternatives available. • Concrete materials must be controlled to avoid contact qith surface waters, wetlands, or buffers. • Requirements are the same as in previous permit. • The permit allows reduction from the 20 acre minimum if the Director of DWQ determines that other BMPs provide equivalent protection. Designation on the plans where the 7 and 14-day ground stabilization requirements of the NPDES permit apply Designation on the plans where basins that comply with the surface -withdrawal requirements of the NPDES permit are located. • No paint or liquid wastes in stream or storm drains • Dedicated areas for demolition, construction and other wastes located 50' from storm drains and streams unless no reasonable alternatives are available. • Earthen -material stockpiles located 50' from storm drains unless no reasonable alternatives available. • Concrete materials must be controlled to avoid contact with surface waters, wetlands, or buffers. • Outlet structures must withdraw from basin surface unless drainage area is less than 1 acre. • Use only DWQ-approved flocculants. PERSPECTIVE VIEW PVC END CAP PVC 90. ELL PVC END CAP PVC TEE PVC PIPE A -SCHEDULE }' HOLES IN 40 PVC PIPE /UNDERSIDE \Ilr) FLEX HOSE -� FILTER -J FABRIC SEDIMENT STORAGE FLOOD STORAGE ZONE SEDIMENT STORAGE ZONE 1'S SEDIMENT CONTROL STONE - PVC VENT PIPE "C" ENCLOSURE R ENTRY UNIT SCHEDULE 40 PVC PIPE PVC TEE BO ORIFICE PLATE BOTTOM SURFACE FRONT VIEW NOTE: ALL BASIN SLOPES SHALL BE 2:1 OR FLATTER. A SKIMMLH W/ / ;BOTTOM B ORIFICE ELEV. 94.00 SKIMMER BASIN DETAIL NTS BASIN SCHEDULE 5• MIN. EMBANKMENT (TOP ELEV. 98.00) SPILLWAY (WEIR) CREST ELEV. 96.5 LENGTH 40• ANTI -SEEP COLLAR A B (DIA) MIN. TOP LENGTH MIN.TOP I WIDTH MINIMUM AREA 4" 1.5" 104' 1 52' S400 SF "A" L ELM STRUCTURAL STONE S' MIN PIPE "A' v amwmrvLL STONE' SHALL BE CLASS 'B' STCNE 'SEDIMENT CONTROL. STONE' SHALL BE No. 5 ON NO. 51 STONE. DIMENSIONS ME MINIMUM ACCEPTABLE UNLESS OTHEWISE SPECIFIED BY THE ENGINEER. SECTION A -A STANDARD ROCK PIPE INLET PROTECTION STEEI (SEE NCDOT #51 WASHED: NCDOT #5 OR #57 WASHEDSTONE / `NATURAL GROUND LM INVERT PIPE 3E' PIPE (MAX) 1B-GAUGE HARDWARE CLOTH )PENINGS) HARDWARE CLOTH & GRAVEL INLET PROTECTION DETAIL MS CONSTRUCTION SPECIFICATIONS: 1. UNIFORMLY GRADE A SHALLOW DEPRESSION APPROACHING THE INLET. 2. DRIVE 5-FOOT, 1.33LWLINEAR FOOT, STEEL POSTS 2 FEET INTO THE GROUND SURROUNDING THE INLET. SPACE POSTS EVENLY AROUND THE PERIMETER OF THE INLET, A MAXIMUM OF 4 FEET APART. 3. SURROUND THE POSTS WITH THE WIRE MESH HARDWARE CLOTH. SECURE THE WIRE MESH TO THE STEEL POSTS AT THE TOP, MIDDLE, AND BOTTOM, PLACING A 2-FOOT FLAP OF THE WIRE MESH UNDER THE GRAVEL FOR ANCHORING IS RECOMMENDED. 4. PLACE CLEAN GRAVEL (NCDOT #5 OR #57 STONE) ON A 2:1 SLOPE WITH A HEIGHT OF 16 INCHES AROUND THE WIRE. AND SMOOTH TO AN EVEN GRADE. 5. ONCE THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED. REMOVE ACCUMULATED SEDIMENTATION, AND ESTABLISH FINAL GRADING ELEVATIONS. 6. COMPACT THE AREA PROPERLY AND STABILIZE IT WITH GROUNDCOVER. i- • M W O L0 't _o v 2' (1.61 M) I� 4' (1.22M) �{ STAPLE PATTERN "C" NORTH AMERICAN GREEN STAPLE PATTERN C: 4' (1.2M) WIDE ROLLS INSTALL USING 1.7 STAPLES/YD SO (2.0 STAPLES/M SO) . CA _ � O • ,a � O 2' (1. 61M) • • 4' (1.22M) STAPLE PATTERN "D" NORTH AMERICAN GREEN STAPLE PATTERN D: 4' (1.2M) WIDE ROLLS INSTALL USING 3.4 STAPLES/YD SO (4.1 STAPLES/M SO), 6" (15.2 CM), 11 GA. WIRE "U" SHAPED STAPLES. LONGER STAPLES MAY BE REQUIRED FOR LOOSE SOIL CONDITIONS. LARGER GAUGE STAPLES MAY BE NEEDED FOR COMPACTED OR ROCKY SOILS. SECURE RECPB BY PLACING STAPLES/STAKES USING THE NOTED SPACING. f F MATTING IN DITCHES MATTING ON SLOPES STAPLES ON CENTERS T} IN TRENCH MIN MATTING SHALL BE STAPLES ON PLACE, IN TRENCH 1'CENTERS AND BACKFILLED- IN TRENCH DIAGRAM OA I3 J� STAPL K? X DIAGRAM OB MATTING INSTALLATION DETAIL STAPLE CHECK PATTERN T� STAPLE) 4' DIAGRAM CO NOMINAL PLAIN RIP RAP STORM WATER (SEE SCR.) PIPE Tf 1 6" OF #57 WASHED STONE FILTER BLANKET OR FABRIC RIP -RAP APRON DETAIL NOT TO SCALE PERMANENT AND TEMPORARY SEEDING SCHEDULE STRAW WATTLE MIN. 12" DIAMET NOTES 1. REFERENCE FIG. 8.06a OF THE DESIGN MANUAL. 2. IN A WELL-DEFINED CHANNEL EXTEND THE APRON TO THE TOP OF THE CHANNEL BANKS. 3. THE TOP OF THE RIP RAP AT THE DOWNSTREAM ENO SHALL BE LEVEL WITH THE RECIEVING AREA OR SLIGHTLY LOWER. RIP -RAP APRON Do La W1 W2 D STONE D50 SIZE 12" 6' 3' 7' 1' 6• 15" 8' 4' 10, /' 6' 18' 9' 5' 11' 1' 6" 24' 13' 6' 15' 1. 5' 6" 36" 16' 8' 18' 2' 12" 42" 20' 9' 23' 2. 5' 12" 11' 26' 3' 12" (2) WOOD STAKES SPACED AS SHOWN BELOW " DEEP TRENCH TYPICAL CROSS SECTION THRU STRAW WATTLE NATURAL GROUND �5 tias CROSS SECTION ro VEE DITCH )ED AREAS: 1. APPLY GROUND AGRICULTURAL LIMESTONE AND FERTILIZER IN ACCORDANCE WITH SOIL TEST RECOMMENDATIONS. 2. IF SOIL TESTS RESULTS ARE NOT AVAILABLE, APPLY LIMESTONE AT THE RATE OF 1-1/2 TO 2 TONS PER ACRE AND 10-10-10 GRADE FERTILIZER AT A RATE OF BOO-900 LB/ACRE. 3. INCORPORATE BOTH FERTILIZER AND LIME INTO THE TOP 4-6 INCHES OF SOIL 4. TEMPORARY SEEDING SCHEDULE: REGION DATES SEEDING MIXTURE RATE MOUNTAINS FEB. 1 - MAY 15 RYE GRAIN 120 LBIAC. KOREANLESPEDEZA 50 LB/AC. MAY 16 -AUG. 15 GERMAN MILLET 40 LB/AC. AUG. 16 -DEC. 15 RYE GRAIN 120 LBIAC. PIEDMONT JAN. 1 - MAY i RYE GRAIN 120 LB/AC. KOBE LESPEDEZA 50 LB/AC. MAY 2- AUG. 15 GERMAN MILLET 40 LB/AC. - AUG. 16-DEC. 30 RYE GRAN 120 LBIAC. 5. PERMANENT SEEDING SCHEDULE: REGION DATES SEEDING MIXTURE RATE MOUNTAINS AUG. 15-MAY 1 KY 31 TALL FESCUE 100 LB/AC. AUG. 20 -APRIL 15 RYE GRAIN 40 LB/AC. AUG. 1 - JUNE 1 SERICEA LESPEDEZA 15 LB/AC. PIEDMONT SEPT 1-APRIL 15 KY31 TALL FESCUE 100 LB/AC. CENTIPEDE GRASS 10 LB/AC. APRIL 16 - JUNE 30 BERMUDA GRASS ' 25 LB/AC. JULY i -AUG- 31 USE TEMPORARY SEEDING, RE -SEED AFTER SEPT. i WITH PERMANENT SEEDING. 6. • APPLY STRAW MULCH AT THE RATE OF 4,000 LB/AC. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. IF USING ASPHALT TACK, APPLYAT THE RATE OF 0.1 GALISY(11GAL/SF). DO NOTAPPLYASPHALT TACK INCLOSE PROXIMITY TO LIVE WATER. GROUND CROSS SECTION TRAPEZOIDAL DITCH NOTES: 1. DRAWINGS ARE NOT TO SCALE. 2. ENDS OF WATTLES SHALL BE TURNED SLIGHTLY UP SLOPE. 3. RECOMMENDED STAKES ARE 2' WIDEN 2' THICK x 24" LONG. STAKES SHALL NOT EXTEND ABOVE THE STRAW WATTLE MORE THAN 2". 4. INSTALL TEN (10) STAKES IN EACH STRAW WATTLE USE AS CHECK DAMS IN ROADSIDE CHANNEL. STRAW WATTLE CHECK DAM FOR DITCHES DETAILS SEEDBED PREPARATION: 1. INSTALL SURFACE WATER CONTROLS IN ACCORDANCE WITH THE APPROVED PLAN. 2. REMOVE ROCKS, ROOTS, AND DEBRIS THAT COULD INTERFERE WITH SEEDBED PREPARATION. 3. AREA TO BE SEEDED SHALL BE LOOSENED TO A DEPTH OF 4-6 INCHES USING A RIPPER, HARROW, OR CHISEL PLOW. 4, SURFACE FOR FINAL SEEDBED SHALL BE TO GRADE, SMOOTH, AND UNIFORM. SLOPES SHALL BE GROOVED OR FURROWED ALONG THE CONTOUR. 5. APPLY LIME AND FERTILIZER IN ACCORDANCE WITH THESE SEEDING SPECIFICATIONS. 6. APPLY SEED AND MULCH IN ACCORDANCE WITH THESE SEEDING SPECIFICATIONS. 7. RESEED AND MULCH AREAS WHERE COVER IS SPARSE OR WHERE EROSION HAS OCCURRED. NOTES: 1. MAXIMUM SLOPE ANGLES SHALL BE NO GREATER THAN THE ANGLE WHICH CAN BE ADEQUATELY RETAINED BY VEGETATIVE COVER OR EROSION CONTROL STRUCTURES. 2, ALL PERIMETER DIKES, SWALES, DITCHES AND SLOPES SHALL HAVE GROUNDCOVER PROVIDED WITHIN 7 DAYS FOLLOWING COMPLETION OF ANY PHASE OF GRADING. 3. ALL SLOPES STEEPER THAN 3.1 SHALL HAVE GROUNDCOVER PROVIDED WITHIN 7 DAYS FOLLOWING COMPLETION OF ANY PHASE OF GRADING. IF SLOPES ARE 10' OR LESS IN LENGTH AND ARE NOT STEEPER THAN 2:1, GROUNDCOVER SHALL BE ESTABLISHED WITHIN 14 DAYS. 4. ALL SLOPES 3:1 OR FLATTER SHALL HAVE GROUNDCOVER PROVIDED WITHIN 14 DAYS FOLLOWING COMPLETION OF ANY PHASE OF GRADING. IF SLOPES ARE GREATER THAN 50 FEET IN LENGTH, GROUNDCOVER SHALL BE ESTABLISHED WITHIN 7 DAYS. 5. ALL OTHER AREAS WITH SLOPES FLATTER THAN 4:1 SHALL HAVE GROUNDCOVER ESTABLISHED WITHIN 14 DAYS FOLLOWING COMPLETION OF ANY PHASE OF GRADING. 6. ON EXISTING LAWNS, ONLY REBEL FESCUE SHALL BE APPLIED, AND ASPHALT TACK SHALL NOT BE USED. 0) CV I_ +� Cn Ln C CD F-4 DO 1_� N L O CO +Iz� W Ln L C C'i 4-1' O ce) =5+A� O C (n LO LO L. N O O CD tJ V 4 �Z J WWI 3U U ^ o N R uJ CO ^ CC W �Lm w Z Q w DO ww Z (o ON N (rc)¢(cUU NN' a(/Ioo(c W J Z_ J J U Q W J ''�_J V^ J LL LZL 1� QUO Z '� U) UJ W J J _JLJJ J W 3:U) U) w TW 1 H SHEET C6 of 9 1 L i 1 to 1r 7-1., i1 11 . Water Line Standard Materials For water line construction, the following specific materials or brands are considered acceptable for the City of Statesville's system. Fire Hydrants: All must have National Standard Threads, 4 q inch valve openings, and open left (counter -clockwise). American Flow Control (American Darling) Mark-73, Mueller Super Centurion 200 and Clow Medallion F-2545 are approved hydrants. Water Valves: All valves must open to the rinht (clockwise). Quarter turn ball valves should be used on sizes up to 2 inch diameter water lines. Each valve shall have a flat head (such as a corp stop) for on/off operation. Resilient wedge type valves must be used on sizes 2A to 10 inch diameter water lines. On 12 inch or larger, butterfly valves with double disc gates must be used. Approved valves are American Flow Control (American Darling), Mueller and Clow. Pipe Materials: All major water mains 6 inch and larger shall be ductile iron class 50 or class 350. Water taps % inch through 1 inch shall be type K soft copper line. Type L hard copper shall be used for 2 inch reduced at the meter for 1 '/2 inch service. Water Meters: All water meters shall be in cubic feet per second. The City can furnish meters (for cost) for application on lines to be dedicated to the City. Size will be determined according to the demand. All meters 3 inch and larger are to have ductile iron pipe to the City side of the meter. Fittings shall be brass for % inch through 1 inch and be flared or compression type. Fittings for 2 inch shall be compression only. Approved types are Ford, Mueller, and McDonald. Approved meter boxes are Brooks #1419 for inch through 1 inch services and Brooks # 1730 for 2 inch services. All boxes must be 18 inch deep with plastic lid and cast iron readers. Any prefabricated meter vault not installed by the City must be pre approved by the City Engineer. Tapping Sleeves: The following area approved standards: American Flow Control (American Darling) - Mechanical Joint. Mueller - Mechanical Joint Romac - Stainless steel with ductile iron flange. ti�Q> CITY OF STATESVILLE DETAIL# REVISED WATER LINES W-1 MAY2010 U rcrounrtr: Lnin a' PUBLIC WORKS DEPARTMENT Standard Materials SCALE: SHEET# CAgb'S�+' N.T.S. 1 OF i RNV 2 0" I HYDRANT SHALL PEN TO THE LEFT C4" STORZ CONNECTION MIN. T VALVE BOX - (SEE DETAIL) USE VALVE BOX STABILIZER PAD WHEN PLACED IN AREAS SUBJECT TO TRAFFIC d A. ,,.u�. z_ CONCRETE BRICKS TYPICAL MEGALUG JOINT - UNDER VALVE BOX RESTRAINT OR EQUIVALENT 6" M.J. GATE 6" DIA. DUCTILE VALVE IRON PIPE MAIN P RESTRAIN EACH JOINT FROM MAIN TO HYDRANT. CONCRETE j C.Y. #57 THRUST BLOCKING WASHED STONE CONCRETE THRUST BLOCKING NOTES: 1. SEE CITY STANDARD MATERIALS LIST FOR APPROVED HYDRANTS 2. DO NOT BLOCK HYDRANT DRAIN W/ BLOCKING 3. ALL HYDRANTS SHALL BE YELLOW IN COLOR. 4. HYDRANTS SHALL BE BEHIND SIDEWALK OR AS PER PLANS. (NO HYDRANTS IN SIDEWALKS) 5. ALL JOINTS FROM MAIN TO FIRE HYDRANT MUST BE RESTRAINED. USE MEGALUG OR EQUIVALENT JOINT RESTRAINT. CONTRACTOR MAY USE THREADED RODS AS AN OPTIONAL JOINT RESTRAINT. RODS MUST RUN CONTINUOUS FROM MAIN TO HYDRANT. 6. GATE VALVE SHALL OPEN TO THE RIGHT. DETAIL # REVISED CITY OF STATESVILLE WATERLINE VJ-6 MAY2010 Typical Hydrant SCALE: SHEET# PUBLIC WORKS DEPARTMENT a Connection N.T.S. 1 OF 1 ROADWAY 2.5' 12" 0°-60° TAP OPTIONAL 3/4" ELL 3/4" TYPE K COPPER MAIN CORPORATION STOP KEEP LINE AS LEVEL WITH MAIN AS POSSIBLE Section View of Connection NOTE: 1. METER IS TO BE SET INSIDE OF THE RNV. 2. METER SHALL NOT BE LOCATED IN DRIVEWAY. 3. ALL PLASTIC METER BOXES SHALL HAVE HEAVY DUTY STRENGTH POLYMER CEMENT (PLASTIC) LIDS WITH CAST IRON VIEWING LIDS AS APPROVED BY THE CITY OF STATESVILLE. 4. ALL SERVICE LINES SHALL COMPLY WITH AWWA REGULATIONS C800. ANGLE METER STOP DUAL CHECK VALVE MUELLER H-14255 MUELLER H742 OR ANY DUAL CHECK VALVE THAT IS A.S.S.E. APPROVED METER 3/4" IRON YOKE BAR 0 I TO CUSTOM WASHED 57 STONE LID BOLT 18" 19 " 32 2 REQ'D h �r J t� " J 12" �- 1 31" 24" 38" --I 4" X 6" CAST IRON READER DETAIL# REVISED CITY OF STATESVILLE WATERLINE W-2 MAY2010 314to -1,r 'gyp PUBLIC WORKS DEPARTMENT SCALE: SHEET # Co WATER SERVICE N.T.S. 1 OF 1 ao�oa WATER ov�va 0 0 7-5/16" DROP LID 5 5116" N 9" 7-3/8" 6S/8" TN I 3/i6 w a ( 7 BOTTOM SECTION 5-3/4" TOP SECTION w NOTES: 1. BODY CASTING TO BE TYLER MANUFACTURE NO.6855SERIES, 5-114" SHAFT, SLIP TYPE, OR APPROVED EQUAL. SCREW TYPE m 3/8" NOT ACCEPTED 2. THE BOTTOM PIECE SHALL BE BEVELED AT THE LOWER END TO FIT AROUND THE STUFFING BOX GLAND AND SHALL REST ON I o„ TWO BRICKS UNDER EACH SIDE OF THE BASE. �•� 3. FITS 4" THRU 12" VALVES P DETAIL # REVISED CITY OF STATESVILLE WATERLINE W7 PHOMM.M9100ta na PUBLIC WORKS DEPARTMENT Standard Valve Box SCALE: SHEET# N.T.S. 1 OF 1 ROADWAY SERVICE SADDLE - WITH DOUBLE BALE 2.5' CORPORATION STOP Section View of Connection NOTE: 1. METER IS TO BE SET INSIDE OF THE RIW. 2. METER SHALL NOT BE LOCATED IN DRIVEWAY, 3. ALL PLASTIC METER BOXES SHALL HAVE HEAVY DUTY STRENGTH POLYMER CEMENT (PLASTIC) LIDS WITH CAST IRON VIEWING LIDS AS APPROVED BY THE CITY OF STATESVILLE. 4. ALL SERVICE LINES SHALL COMPLY WITH AWWA REGULATIONS C800. SIDEWALK -KEEP LINE AS LEVEL WITH MAIN AS POSSIBLE RIW I rTO STOMER WASHED 57 STONE LID BOLT 18 " 19 " 32 2 REQ'D I�-r I-' t 12" L� 1 31' 24" -I I- 38" �I 4" X 6" CAST_IRON READER METER WILL BE SUPPLIED BY THE CITY OF STATESVILLE BALL VALVE METER INLET ANGLE CHECK VALVE ski OUTLET (DOUBLE CHECK) o q BYPASS WITH BALL VALVE DETAIL # REVISED - CITY OF STATESVILLE WATERLINE W-3 2" WATER PUBLIC WORKS DEPARTMENT SCALE: SHEET # c SERVICE N.T.S. 1 OF i FINISH GRADE 14" DIAMETER 23" DIAMETER NO. 3REBAR NO. 3REBAR 4 • V A/�. • , .; + -=ate .: F 4 A r .. 4. F ..t •. 4l 4 ''. . ..� .4 .• PLAN SECTION A -A VALVE BOX TOP MARKED WATER PRECAST VALVE BOX DETAIL # REVISED CITY OF STATESVILLE WATERLINE W-8 nmimn",MWaut� . •p PUBLIC WORKS DEPARTMENT Valve Box Protector SCALE: SHEET # N.T.S. 1 OF 1 �.9 .d • +L a' 4 DUCTILE IRON PIPE 4 d. DIA. • ...d d fl5t�' 4 ew;a • • , . 3r " • • °i MEGALUG 1100 SERIES , z-' RESTRAINT OR EQUIVALENT a • I OPTIONAL 2" . ' ORIFICE W/ CAP A MECHANICAL JOINT PLUG THRUST COLLAR MEGALUG 1100 SERIES RESTRAINT OR EQUIVALENT W ISOMETRIC VIEW W W W aW W W V" NOMINAL PIPE DIAMETER "D" "A" "B" TRENCH WIDTH 'W" REINFORCING STEEL BARS SPACING (EACH WAY) 6"- 8" 12" 12" 26" # 6 12" 10" -12" 16" 16" 30" # 6 6" 16" 21" 21" 36" # 6 6" M.J. PLUG PLAN VIEW """"" "•�"' " ` NOTES: 1. POUR CONCRETE AGAINST FIRM. UNDISTURBED SOIL. FILL AGAINST COLLAR TO BE COMPACTED TO 90% PROCTOR FOR F ALONG THE PIPE ON BOTH SIDES OF THE COLLAR. 2. COMPLETELY BACKFILL AND COMPACT BEFORE PRESSURE TEST. 3. TRENCH WIDTHS ARE MAXIMUM FOR 10' EACH SIDE OF COLLAR. DETAIL # REVISED CITY OF STATESVILLE WATERLINE W-5 MAY2010 a „an.;wnarTuRE PUBLIC WORKS DEPARTMENT Thrust Collar & Dead End SCALE: SHEET # G1 N.T.S. 1 OF 1 LOCKABLE FLIP TOP FIBERGLASS ENCLOSURE X / 10° X BRONZE 1/4 TURN J 10" SHUTOFFVALVES / PLAN VIEW INSTALL 120V LOCKABLE FLIP RECEPTACLE WITH GFCI TOP FIBERGLASS FOR HEATER CONNECTION ENCLOSURE VARIES DRAIN PORT TYPICAL EACH SIDE BRONZE 114 TURN SHUT OFF VALVES z 4• . " CONCRETE SLAB m 3000 PSI @ 28 DAYS (CHECK ENCLOSURE SIZE FOR SLAB DIMENSIONS) USE COPPER FROM STREET o e CONNECTION TO BACK SIDE OF DCV. SECTION X_X NOTE: 1. ALL BACKFLOW ASSEMBLY'S SHALL BE MAINTAINED BY THE CUSTOMER. 2. ENSURE ASSEMBLY WILL FIT WITHIN FIBERGLASS ENCLOSURE. CHECK DIMENSIONS BEFORE ORDERING ENCLOSURE. 3. SLOPE CONCRETE PAD TO DRAIN PORTS. 4. ASSEMBLY SHALL BE PLACED ON THE CUSTOMERS PROPERTY BEHIND THE METER. IF APPROVED BY THE CITY ENGINEER, THE ASSEMBLY MAY BE PLACED INSIDE OR BESIDE THE BUILDING. 5. ASSEMBLY SHALL BEACCESSIBLE BY CITY INSPECTORS. 6. METER SHALL READ N CUBIC FEET. ISOMETRIC VIEW OF 7. AS AN OPTION THE ASSEMBLY MAYBE PLACED IN A BELOW GROUND VAULT. THE VAULT SHALL BE APPROVED BY THE CITY ENGINEER. TYPICAL ENCLOSURE DETAIL # REVISED CITY OF STATESVILLE WATERLINE �. W-12 JAN 2011 lllckfm. PUBLIC WORKS DEPARTMENT314" - 2" DCV Assembly SCALE: SHEET# : (Above Ground) N.T.S. 1 OF 1 +J (U (U L U) Ln L C CD •-4 W ri N L CU U (TD �Z(0 LO L C Cr) i� O O C_ Ln L N O o OD V a Z 4A WD Z O 3 V 0 N v Lu m ^ cc CC Lu z¢oaz U• • m O "' O Lu Q 3 > a Ch002 Q J Z J J W J < TQ 2 Q�0 rr^^ Z v! W J J J J W = > � � W W F -- U) SHEET " V V 1 C7 of 9 yEXISTING LINE _ � I UNDISTURBED EARTH —I I I I � � BEHIND BLOCKING —III— '� -III—I_i i l I 11i1 -III—=I- _=_ - .4. AA —— - — - — - — — —' a II i l —III IIII-11 I - CONCRETE BLOCKING =III II11 _ I" —' PLAN VIEW USE VALVE BOX STABILIZING PAD WHEN PLACED IN AREAS SUBJECT TO TRAFFIC III UNDISTURBED EARTH VALVE BOX I (SEE DETAIL) Iil l TAPPING SLEEVE CONCRETE BRICKS TI UNDER VALVE BOX I i M.J. GATE VALVE 1 - 1 1 MEGALUG JOINT RESTRAINT I11 _ OR EQUIVALENT "C"SEE CHART d� III , ` /,/\\\/\\/�\�\\�\\ \\ / UNDISTURBED EARTH CONCRETE BRICK BLOCKING CONCRETE BLOCKING COMPACTED EARTH SECTION A -A NOTES: 1. THE GATE VALVE SHALL OPEN TO THE RIGHT. 2. USE FULL BODY TAPPING SLEEVE WITH GASKET AND MECHANICAL JOINT OUTLET. 3. CONCRETE BLOCKING IS TO BE FORMED TO ENSURE ACCESSIBILITY TO FITTINGS AND POURED AGAINST UNDISTURBED EARTH. 4. FITTINGS ARE TO BE COMPLETELY WRAPPED WITH PLASTIC, PRIOR TO POURING CONCRETE. 5. CONCRETE TO BE MINIMUM 3,000 PSI. @ 28 DAYS. DETAIL # REVISED WATER LINE t CITY OF STATESVILLE W-17 iM0liYfeY•A61Jtlxlil°:117 PUBLIC WORKS DEPARTMENT Tapping Sleeve SCALE: SHEET# N.T.S. 1 OF 1 DOUBLE CHECK VALVE ASSEMBLY WITH TEST PORTS AND 1/4-TURN BRONZE SHUT OFF VALVES BUILDING LOWEST FLOOR 2" OR SMALLER DOMESTIC WATER SERVICE LINE (SEE SITE PLANS FOR SIZE AND MATERIAL) 36" COVER UNLESS OTHERWISE NOTED OR REQUIRED FIRE PROTECTION SUPPLY PIPING FROM WATER MAIN (SCH 80 PVC, AWWA C900 DR-18, DUCTILE IRON, OR GALVANIZED STEEL PIPE - AS NOTED ON DRAWINGS OR SPECIFICATIONS) W W W J W W W O CONTRACTION JOINT 5 5'TYPICAL CLEANOUT PROTECTOR REQUIRED IF TYPICAL SEE PLANS Y Y CLEANOUT IS LOCATED WITHIN TRAFFIC AREAS BRASS PLUG EXPANSION q_ d JOINT .v y"��. 106`1 .r PER FT. W W W 1/Z PER FT,* a d - c a. W W W W J• "Y W 'a ,�I 3 SCH. 40 PVC PIPE OR D.I.P. - I SIOPEO� /,• nA\N 45° BEND — ROMAC SADDLE TEE W/ GASKET SKIRT OR EQUIVALENT. INCLUDE STAINLESS STEEL STRAP (MUST MEET APPROPRIATE ASTM STANDARDS) NOTE: 1. CLEANOUT SHOULD BE LOCATED AT THE RIGHT-OF-WAY OR EASEMENT LINE. 2. ALL TAPS WILL BE MADE WITH A TAPPING MACHINE 3. IF LATERAL HAS LESS THAN T OF COVER IT SHALL BE DUCTILE IRON PIPE - PLUG - COMBINATION WYE & 118 BEND DETAIL # REVISED CITY OF STATESVILLE SANITARY SEWER S-8 MAY 2010 umuLrerAaunaruac. . PUBLIC WORKS DEPARTMENT Sewer Stub -Out Detail SCALE: SHEET# GHQ N.T.S. 1 OF 1 ISOMETRIC VIEW 1/8.1� t14" TOOLED EDGE 1/8" RADIUS - 1 /8" f 1/4' N SAW SEALANT Z-1/2" EXPANSION MATERIAL CONTRACTION JOINTS EXPANSION JOINT SECTION VIEW NOTE TO SYSTEM I 47 BY PLUMBING CONTRACTOR t CHECK VALVE FIRE PROTECTION GENERAL SCHEMATIC OF DOUBLE CHECK VALVE APPURTENANCES BY FIRE WITH DETECTOR METER PROTECTION SYSTEM CONTRACTOR/DESIGNER INSTALL TEMPORARY j FLANGE COVERS WITH RESTRAINT FOR PRESSURE TESTING iv END OF WORK BY SITE UTILITY CONTRACTOR GALVANIZED STEEL WITH BITUMINOUS COATING OR DIP RISER PIPE CAST IRON, DI FITTINGS WITH RETAINER GLANDS (MEGALUG 1100 OR EQUAL) OR THREADED IRON FITTINGS IF CONNECTING <4" DIAMETER PIPE. PIPING FROM FDC (SCH 80 PVC, AWWA C900 DRA8, DUCTILE IRON, OR GALVANIZED STEEL PIPE - AS NOTED ON DRAWINGS OR SPECIFICATIONS) CONCRETE THRUST BLOCKING DOMESTIC AND FIRE PROTECTION PIPING INTO BUILDING NTS TOOLED EDGE 1/8" RADIUS 1. INSTALL 1/2" EXPANSION JOINTS AT 50' O.C. AND WHERE WALKS ABUT OTHER WALKS, OR OTHER CONSTRUCTION. SCORE WALK TO A DEPTH OF D/4 AT F TO 6' O.C. 2. ALL SIDEWALKS SHALL BE 3000 PSI. 3. CONCRETE SHALL BE BROOM FINISHED WITH 2.5" STRIKING AROUND EDGES TO GIVE A PICTURE FRAME APPEARANCE. CITY OF STATESVILLE PUBLIC WORKS DEPARTMENT STREET Concrete Sidewalks EDGE DETAIL # REVISED ST-9 MAY 2010 SCALE: SHEET # N.T.S. 1 OF 1 • a� 6� d• R - d ✓p a � W ! v d, d ���v • , d. d • MN ,. 4 •M•M�." '�i �• d a2 f E d "•.{4,.• i •d• r W W V d F NOTES: 1. CURB SHALL BE DEPRESSED AT DESIGNATED AREAS EVEN IF SIDEWALK IS NOT THERE ISOMETRIC VIEW 2. ALL HANDICAP ACCESS RAMPS SHALL BE INSTALLED AS PER A.D.A. SPECIFICATIONS. 3. NO SLOPE ON THE WHEELCHAIR RAMP SHALL EXCEED 1712" (12:1) IN RELATIONSHIP TO THE GRADE OF THE STREET. CURB AND GUTTER BEYOND PAVEMENT -. CURB SEE PLANS 12:1 MAX SLOPE THREADED NIPPLE FIRE DEPT. CONNECTION PER CITY STANDARDS (2-1/2^ STORZ WITH 30" TURN DOWN) 4"GALVANIZED QUARTER TURN (V STEEL PIPE BALL VALVE It O r iD M zxzxs^ CONCRETE N COLLAR BITUMINOUS COATINGAPPLIED - TO GALVANIZED �• -III MINIMUM 3/4" (HOT DIP) 9 GALV. RODS WITH Z BITUMINOUS COATING ON BOLTS AND NUTS. IIIIIIh I'll�ll I CONCRETE THRUST COLLAR 4" SCHEDULE 80 PVC OR C900 DR18 TO FIRE SPRINKLER RISER ROOM STUB UP 12" ABOVE FINISHED FLOOR (CONNECTION TO RISER TO BE ABOVE BACKFLOW PREVENTER AND SHALL INCLUDE A CHECK VALVE ON THE FDC PIPING -NOT BY SITE UTILITY CONTRACTOR) -SEE DETAIL DETAIL# REVISED CITY OF STATESVILLE STREET ST-10 . e1 PUBLIC WORKS DEPARTMENT Accessible Curb -Cut SCALE: SHEET O N.T.S. 1 OF 1 FINISHED GRADE '. BALL DRIP IN GRAVEL. tea" •° . WRAP GRAVEL IN FILTER FABRIC CONCRETE THRUST BLOCK is 17':31„a.l h•.. HI•.Elam, SIGNS ADJACENT TO EACH FDC. RED LETTERS ON WHITE BACKGROUND. MINIMUM 12"x6• EACH. MOUNT ON GALVANIZED STEEL POST. IDENTIFY BUILDING NO. OVERLAP NEW ASPHALT AND STONE 12" MIN. BRACE TRENCH AS REQUIRED BY EXISTING SOIL CONDITIONS PIPE DIAMETER it LESS THAN 14" 12" 14" TO 36" 18" MORE THAN 24" 24" DETAIL# REVISED - CITY OF STATESVILLE WATERLINE W-14 MAY2010 r PUBLIC WORKS DEPARTMENT Trench, Bedding, & SCALE: SHEET# Backfill in Paved Roads N.T.S. 1 OF 1 C L +J CM U0 c CO 14 CO N L_ L a) Uco + Z CD Cn U) .L C P') 4. O Cr) 04',T O C U) m , LID L.N 0 0 CO V 4 Z J WD Z 0 J ti LLI Q Z 0 ti U cc C0 Z O W Q J Z J J U W _I Q I— �_L/ Z U) L QUO Z CO Q } W W J J Illf -__I J W 1:U) Of U) W W Q 2 � U) SHEET i C8 of 9 m 21'-0 NO. 4 REBAR ©12" ON CENTER EACH WAY JOINT O 1 4 04 1. THE EIGHT INCH THICK (MINIMUM) CONCRETE PAD SHALL BE OF 4,000 PSI STRENGTH. 2. THE CONCRETE PAD SHALL BE PLACED ON 4" OF COMPACTED ABC. 3. THE RE -BARS AS SHOWN SHALL BE SUPPORTED BY CHAIRS. DUMPSTER CONTAINER CONCRETE PAD NM 30" (4' HIGH) 36" (6'-8- HIGH) 36" (10' HIGH) TOP HINGE (180" SWING) BOTTOM HINGE (180' SWING) - 2-3/8" O.D. LINE POSTS (OR AS SPECIFIED) 6 GA. ALUM. WIRE TIES 0 12" O.C. (TYP.) FABRIC 0 1-1/2" (MAX.) FROM FINISHED GRADE `- DIAMETER (SEE SPECIFICATION) CHAIN LINK FABRIC 12'-0" TO 20'-0" (SEE PLAN) BANDS 12" MINIMUM DIAMETER \ \ 12" DIAMETER CONC. FOOTING (TYP.) " •\ CONC. FOOTING NOTES: 1. FENCE FABRIC SHALL BE SECURED TO GATE FRAMES WITH KNUCKLED SELVAGE ALONG ALL EDGES FOR ALL TYPES CHAIN LINK FENCE INSTALLATIONS. 2. REFER TO SPECIFICATIONS - FOR ALL PIPE SIZING, WIRE FABRIC GAUGES, FOOTING SIZES & OTHER APPLICABLE INFORMATION. 3. ALL CONCRETE FOOTINGS AROUND POSTS AT GROUND LINE SHALL BE MOUNDED & SLOPED FOR POSITIVE DRAINAGE. DOUBLE ACCESS GATE (TYP) N.T.S. r,r S9.58 6" ABC if J 1• '.4A.. Y-� MiY �hT 1� Sk•. Y A- YiY. .1 TACK COMPACTED SUBGRADE COAT (PER SPECIFICATIONS) LIGHT -DUTY ASPHALT PAVING NTS 2' S9.68 " ABC TACK71 COMPACTED SUBGRADE COAT (PER SPECIFICATIONS) HEAVY-DUTY ASPHALT PAVING NTS +<NUCKLED SELVAGE 0 TOP & BOTTOM (TYP.) 1-5/8" O.D. TOP RAIL BALL CAP WITH SET SCREW OR SPOT WELDED TERMINAL OR CORNER POSTS 2-7/8" O.D. SCH.40 GALV. STEEL PIPE (4" O.D. IF > 10' IN HEIGHT) 2" MESH, CHAIN LINK FABRIC, 9 GA. ALL OTHERS TENSION BAR (TYP.) TENSION BAR BANDS/CLIPS 0 12" O.C. 1-5/8" O.D. INTERMEDIATE RAIL (NOT REQUIRED FOR FENCING LESS THAN 6' HIGH) -TIES ALONG TOP, INTERMEDIATE, & BOTTOM RAILS 0 12" O.C. (TYP.) 1-5/8" O.D. BOTTOM RAIL (NOT REQUIRED FOR FENCING LESS THAN 6' HIGH. SUBSTITUTE 7 GA. GALV. STEEL COIL WIRE WHERE RAIL NOT REQUIRED) CONCRETE FOOTING MMPACTED SUBGRADE (NO INTERMEDIATE RAIL) )H (INTERMEDIATE RAIL) 30" (4' HIGH) 36" (6'-8' HIGH) 36" (10' HIGH) NEW 5-0- 4"-4,000 PSI CONCRETE CURB AND GUTTER JOINT FILLE TYP. CROSS-SECTION OF SIDEWALK AGAINST CURB NTS 6'0' 4'-4, 000 PSI NEW PAVEMENT 6" CONCRETE 1/� 4"PEN FT. COMPACTED a. SUBGRADE MIN TYP. CROSS-SECTION OF SIDEWALK AGAINST PAVEMENT NTS VARIES - SEE PLAN ••• " • - IN •ail ► ►• 1\ u JOINT SEALER 0 1„ SURFACE OF "16 PAYMENT :A 1 /2" JOINT FILLER TRANSVERSE EXPANSION JOINTEXPANSIONJOINT IN SIDEWALK KK NTS (ONE REQ'D EVERY 30' AND AGAINST ALL OTHER EXTERIOR HARD ABUTTING VERTICAL SURFACES.) 6' 36" 6' I�---JI r 7" OR 36' J PLAN VIEW NCDOT FRAME,GRATE, AND HOOD OR FRAME AND GRATE 2 COURSES OF BRICK WITH MORTAR ° STANDARD ACCESS PANELS VARIES (SEE PLANS) I A• SECTION VIEW CATCH BASIN (CR) A DROP INLET fDll NTS CATCH BASIN NOTES: 1. CONCRETE SHALL BE 4.000 PSI AT 28 DAYS. 2. REINFORCING SHALL BE WELDED WIRE MESH IN KNOCKOUTS AND #4 BARS IN FLOOR AND CORNERS IN ACCORDANCE WITH AASHTO STANDARDS FOR H-20 LOADING. 3. PRECASTER SHALL BE TINDALL CONCRETE, STAYRIGHT TANK, D&M CONCRETE, OR APPROVED EQUAL. 4. CATCH BASINS SHALL HAVE A STANDARD D.O.T. FRAME, GRATE, AND HOOD OR PARKING LOT GRATES AS REQUIRED. RESERVED PARKING 10 12" SIGN "A" SIGN R7-8 12„ MAXIMUM PENALTY SIGN "B" SIGN R7-8D io SIGN "C" VAN ACCESSIBLE SIGN PARKING AREA 1 /2" RAD 110" 1 J " RAD /8" RAD 1" -� 1 = T f0T •°. n I I 1,8„• CURB AND GUTTER NTS SIGN 1. LEGEND & BORDER - GREEN C. 2. WHITE SYMBOL ON BLUE EEERVEO BACKGROUND YAKKING S�GNACgGROUND - WHITE [6] SIGN 1. LEGEND do BORDER -GREEN SIGN 2. BACKGROUND -WHITE .*.,NM, SIGN "C„ rIN .... (FOR SPACES SO DESIGNATED) F o 1. LEGEND &BORDER -GREEN o c 2' STEEL 2. BACKGROUND - WHITE z z PIPE UPDATE EXISTING SIGNS TO 0 v MEET CURRENT REQUIREMENTS. 4 ,f1 NISHED /GRADE 10 CONDITION !1: PEDESTRIAN PATH DOES NOT PASS UNDER OR "DVt AROUND SIGN. X12 -3/8" TYP. CONDITION /2: PEDESTRIAN PATH24 GOES BY UNDER, OR ONCRETE -3/8' TYP. AROUND SIGN. 1. REGARDLESS OF AGE, ALL BARRIER FREE SIGN DETAIL ACCESSIBLE SPACES SHALL NTS BE IDENTIFIED BY ABOVE- GROUND SIGNS ONLY. 2. NEW SPACES SHALL NOT USE GROUND -PAINTED SYMBOLS. 3. ACCESSIBLE SPACES ARE REQUIRED TO BE STRIPED OFF ONLY, BLUE COLORING IS NOT NECESSARY NOR REQUIRED. 4. USE WHITE PAINT ON ASPHALT PAVEMENT PER STRIPING SPECIFICATIONS. 5. ALL STRIPING PAINTED ON PARKING SPACES SHALL BE ONE COAT OF GUDDEN SERIES 22683 ULTRAHIDE LATEX WHITE TRAFFIC PAINT, BARRIER OR EQUAL APPLY 2.0 MIL DRY FILM THICKNESS MINIMUM. FREE PARKING SIGNS DETAIL PROVIDE DETECTABLE WARNINGS ON RAMP SURFACE AS PER LATEST A.D.A. REQUIREMENTS. 5' OR GREATER PAVEMENT (SEE PLAN) JOINT SEALER 1/8" RAD SURFACE OF GUTTER 1 /2"_+ JOINT FILLER TRANSVERSE EXPANSION JOINT IN CURB AND GUTTER NTS GENERAL NOTES FOR CURB AND GUTTER: 1. CONTRACTION JOINTS SHALL BE SPACED AT 10' INTERVALS, EXCEPT THAT A 15' SPACING MAY BE USED WHEN A MACHINE IS USED OR WHEN SATISFACTORY SUPPORT FOR THE FACE FORM CAN BE OBTAINED WITHOUT THE USE OF TEM- PLATES AT 10' INTERVALS. JOINT SPACING MAY BE ALTERED BY THE ENGINEER TO PREVENT UNCONTROLLED CRACKING. 2. CONTRACTION JOINTS MAY BE INSTALLED BY THE USE OF TEMPLATES FORMED BY OTHER APPROVED METHODS. WHERE SUCH JOINTS ARE NOT FORMED BY TEMPLATES, A MIN. DEPTH OF 1 Kz" SHALL BE OBTAINED. 3. ALL CONTRACTION JOINTS SHALL BE FILLED WITH JOINT SEALER. 4. EXPANSION JOINTS SHALL BE SPACED AT 90' IN- TERVALS AND ADJACENT TO ALL RIGID OBJECTS. 5. CONCRETE SHALL BE 4,000 PSI AT 28 DAYS. 24"0 MANHOLE FRAME AND COVER °A A W9LK .. . A 36:' MIN. A 10® °V IIIIIIIIIIIIIII��''' , . . Dill IIIIIIIIIIIIIIIII ,12 14. 12 �IDLP �'• TYPICAL. ° • •.A NOTE: ALL BARRIER FREE RAMPS SHALL BE INSTALLED AS PER A.D.A. SPECIFICATIONS. CURB AND GUTTER BEYOND PAVEMENT ice- 6MIN. I srncwai r I SLOPE CURB DOWN AT SAME RATE AS SIDE FLARES, TYP. BOTH SIDES \-12:1 MAX SLOPE CURB SECTION A -A BARRIER FREE RAMP DETAIL A NOT TO SCALE 0 N �w ro •- g � m oc w i¢oi:z I- m O W W •• 2 � o PRECAST, REINFORCED FLAT o ¢ 3 N SLAB TOP a � oQ a ¢ O If) •1i co ri N L r (1)U U +j z co LO L C M +p O co =3 +� t O C U cis L. N O O CC) lq- m v 4 Z 4A J WN 3 u U d ey Ncr -1 a U:W to J ti LLJ 0 U Z) Z O Q4 J Z ° SQUARE STANDARD ACCESS % () O ti Cl-PANELS w J Q�V � CD A L O L.L Q > Z SECTION VIEW Q U� JUNCTION BOX DETAIL LL! I J J NTS W JUNCTION BOX: LU = (> W C/) W CONCRETE SHALL BE 4,000 PSI AT 28 DAYS. W REINFORCING SHALL BE WELDED WIRE MESH IN = KNOCKOUTS AND #4 BARS IN FLOOR AND CORNERS INco F ACCORDANCE WITH AASHTO STANDARDS FOR H-20 LOADING. PRECASTER SHALL BE TINDALL CONCRETE, STAYRIGHT TANK, D&M CONCRETE, OR APPROVED EQUAL. SHEET JUNCTION BOX SHALL HAVE PRE -CAST FLAT TOP WITH MANHOLE FRAME AND COVER IN LIEU OF GRATE. SIZE AS REQUIRED. C9 of 9 Common Name Botanical Name Large Shade Trees A Bald Cypress Taxodium distichum B Red Oak Quercus rubra C Black Tupelo Nysso sylvatico "Wildfire" Ornamental Trees D Nellie R. Stevens holly ltex x"Nellie R. Stevens" E Yoshino Cherry Prunosx yedoensis "Akebono" F Crape Myrtle Logerstroemia indica "Natchez" Quantity Minimum Caliper Minimum Minimum Height Container Size 14 2-1/2 inches at N/A N/A 41 6 foot height 9 o 15 14 N/A 8 Feet N/A 6 Large Shrubs G & H Alternating plants or clusters of plants using: 40 N/A N/A *Gallons 1 BurgundyLoropetatum LoropetolumChinensevrubrum'Burgundy" 2 Red Tip Viburnum Viburnum cinnamomifolium 41 LANDSCAPING REQUIREMENTS PER CITY OF STATESVILLE ZONING ORDINANCE 1 TYPE C BUFFER 70 points per 100 feet x 715 x 715 = 501 points required Provided: 14 shade trees x 12 points/each 168 — — — — — — — — — — — — — — _ .... _ - 15 ornamental trees x 6 points/each = 90 / 81 large shrubs x 3 points/each = 243 Total 501 points / 109 e / 2 STREET YARD BUFFER 136 points per 100 feet x 1,492' 540 points required / (((yyy©� \011�✓/Qi Provided: 41 shade trees x 12 points/each - 492 8 ornamental trees x 6 points/each = 48 \ O Total 540 points / \ \ O .....­esol t.eec .,0.'19 ..n.4f..o <n�roc = 1 Rn nnintc ranuirPH . \ / _ to / WOLF CREEK LANE (50 ZONED R-5MF EXISTING USE: SINGLE FAMILY STONEBRIDGE SUBDIVISION LANDSCAPING/PLANTING LEGEND SHADE TREE gv)/, b/AIPe ORNAMENTALTREE LARGE SHRUB ZONED R-5MF EXISTING USE: VACANT bQ4 �0/A\P ACTIVE N —� SPA Z / , PICNIC, / IN K� K \ . r ti \© /� VENTURE PROPERTIES I, LLC REMAINDER OF TRACT B-PB 56 PG 69 6.36 ACRES +/- DEED REF: DB 1059 PG 635 60' RADIUS CIRCLE TO SHOW COVERAGE COMPLIANCE (TYP.) -N- u) C (O •,i DO r I N L N U +Az rn LO c M 4! o 7 4-A o c rn cz LN P) L ooCC) t� v 4 W~ 3z U U Z Q J CL W U co Z Q 9iti1� a v \ \ Id �I r @ s 4 y ¢ 17 -}%/ ' o ` ``. / ° r�, MOUND SOIL FIRMLY Z r` LL1 \TRF a r '/P' ci10'/ } 41� r Pi r / ,y, `yam' / r� / MIN. APPROVED AROUND RAISED ROOT BALL \ APPROVED MULCH � m O a \o ` /NIP\ STQ "✓C i / �/ i ' o/ '�� ' '•' TYP. COLLAR T. TOP OF ROOT BALL 2'-3" \ \ O Q 36HDP 4.4 / �; \ ABOVE EXISTING GRADE \ 2 U Q W R \ 0 �]NjlL/pHT �MWE-84.3 4 / / ° I \ ' a L7 Q Q ° \ \ ♦ 8O A / b/`Bfw/ s/ / / \ 1 NOTES \ Id G^ T ` \A�i v/ �fll�/Q- % ' '• / 4" MIN -;' MIN. 10" i OMIT COLLAR AROUND El& SHRUB ' -- o \ TS / / O© j/ / �•' / T— WHEN IRRIGATION SYSTEM f5\PRESENT. / s / N"TRENCH AROUND DEPTH '3 ' ENTIRE PLANTING BED I 2. INSTALLTOP E PLANT BALL 2'--3'\ I Q 1 ABOVE ADJACENT GRADE. EDGE OF r!wtPLANT MIX 3. TAMP PLANTING MIX FIRMLY AS PIT IS\ J z AIR RELEASE V ` _ O A� W -W 9 y�o /'r / / PLANTING BED (AS SPECIFIED) FILLED AROUND EACH PLANT BALL. \ I J \ TOP OF TOP -86.7 N WMONUMENT �' '�C �� / CUT ROOTS AS NECESSARY 4. SOAK EACH PLANT BALL AND PIT \ ^`� IMMEDIATELY AFTER INSTALLATION. \ O INV-83.70 �{�1�/�y/ /NYC \ �s .•' / IN CONTAINERIZED PLANTS TAMP SOIL MIX UNDER EACH PLANT \ / U o SIGN / \\\\ /q � THAT ARE POT BOUND BALL TO MINIMIZE SETTLEMENT \ I U) N ` ti PERMANENT / "\\ \ W _jj Q O�T a \°� \ DETENTION POND a\aQ /" /*� ; \�' // ZONED R-5MF TYPICAL SHRUB PLANTING DETAIL `\ _ U y ` min, /' .> / EXISTING USE: MULTI -FAMILY RESIDENTIAL \. Q 0 HOF 'gy; ° ,�" /,�' ,: = IN IM p (GREYLIN RIDGE APARTMENTS) \ '�� I� 1 a/o .•= ' / NOTES: \ I � O O All „P o/ '���i ��'/ // 1. REMOVE WIRE OR NYLON TWINE FROM \\ Q �� ' BALL. \ z ®\ 2. SOAK ROOT BALL AND PLANT PIT 11 �� IMMEDIATELY AFTER INSTALLATION. / / � 1 LU •` �SO�� - a \°\ \ �/� / al 6" SLIP KNOT WITH STOP KNOT. /y / W 3/4' NYLON STRAP -D \ 8 4 . �i g/ 6' LARGER THAN TREE DIAMETER / ROOT CROWN TO BE KEEP MULCH AWAY FROM / //'� \m NV �`� \ ; ®/ t'�'•''/ / °\® AT FINISH GRADE*' TRUNK I'TOY // VJ Uj 1'x2"x18" WOOD STAKE WITH / W N CENTERED 3/8" HOLE MAXIMUM LAYER OF MULCH / Q DRIVEN IN LINE WITH STRAP / DPE-83.3 ..L. FINISH / �/� GRADE / VJ ZONED R-5MF EXISTING USE: MULTI -FAMILY ` \ `` ° UNDISTURBED EARTH // �% i �/ .�� \ ♦• . / \ / 40 9 40 80 (NORTH POINTE APARTMENTS) IqV IN 38HDPE-83.8 V WT 36HDPE-84.1 REMOVEFROM TYPICAL E XCS PLANTING MIX ROOT / \ SYSTEM, UP TO 1' DEPTH. SHEET REJECT PLANTS WITH MORE THAN*". LL DIP.. G`RAPHIC SCALE - FEET \\ REMOVE TOP 113 BURLAP AND VARIES / ANY NAILS/PINS, ETC. RAT THEISE PIT CORRECT HEIGHT.FI MSOIIBOTTOM TO SETL UNDER // 1"=40' 7 ROOT BALL. / L / OF / .// TREE PLANTING DETAIL / o■ V • V