Loading...
HomeMy WebLinkAboutSW3210403_Application Form_20210824DEMLR USE ONLY Date Received Fee Paid Permit Number Applicable Rules: ❑ Coastal SW - 1995 ❑ Coastal SW - 2008 ❑ Ph II - Post Construction (select all that apply) ❑ Non -Coastal SW- HQW/ORW Waters ❑ Universal Stormwater Management Plan ❑ Other WQ M mt Plan: State of North Carolina Department of Environment and Natural Resources Division of Energy, Mineral and Land Resources STORMWATER MANAGEMENT PERMIT APPLICATION FORM This form may be photocopied for use as an original I. GENERAL INFORMATION 1. Project Name (subdivision, facility, or establishment name - should be consistent with project name on plans, specifications, letters, operation and maintenance agreements, etc.): 233 Randolph 74 Solar I, LLC 2. Location of Project (street address): 2200 Southern Drive City:Shelby County:CieveIand Zip:28150 3. Directions to project (from nearest major intersection): From US-74 west of Shelby, turn north (right) on NC-226 Polkville Road andgo 0.47 miles. Turn west left an Randol ph Road SR-1308 and continue 1 mile. Turn north (right) on Southern Drive SR-1433 . Pra•ect entrance is approximately 0.12 down road on left. 4. Latitude:35° 18' 37.0" N Longitude:81° 35' 08.4" W of the main entrance to the project. H. PERMIT INFORMATION: 1. a. Specify whether project is (check one): ®New ❑Modification ❑ Renewal w/ Modificationt tRenewals with modifications also requires SWU-102 - Renewal Application Form b. If this application is being submitted as the result of a modification to an existing permit, list the existing permit number its issue date (if known) , and the status of construction: ❑Not Started ❑Partially Completed* ❑ Completed* *provide a designer's certification 2. Specify the type of project (check one): ®Low Density ❑High Density ❑Drains to an Offsite Stormwater System ❑Other 3. If this application is being submitted as the result of a previously returned application or a letter from DEMLR requesting a state stormwater management permit application, list the stormwater project number, if assigned, and the previous name of the project, if different than currently proposed, 4. a. Additional Project Requirements (check applicable blanks; information on required state permits can be obtained by contacting the Customer Service Center at 1-877-623-6748): ❑CAMA Major ®Sedimentation/Erosion Control: 17 ac of Disturbed Area ❑NPDES Industrial Stormwater E404/401 Permit: Proposed Impacts 148 LF of stream impact _ b.If any of these permits have already been acquired please provide the Project Name, Project/Permit Number, issue date and the type of each permit:NCDEQ Erosion Control Permit: 233 Randolph 74 Solar 1, LLC / _ CLEVE-2021-025 1 03-25-21: USACE 404/401: 233 Randoioh 74 Solar. LLC 1 SAW-2014-022561 03-25-21 5. Is the project located within 5 miles of a public airport? ❑No ®Yes If yes, see S.L. 2012-200, Part VI: htt ortal.ncdenr.oi web lr rules -and -re ulations Form SWU-101 Version Oct. 31, 2013 Page 1 of 6 III. CONTACT INFORMATION 1. a. Print Applicant / Signing Official's name and title (specifically the developer, property owner, lessee, designated government official, individual, etc. who owns the project): Applicant/ Organization: 233 [Zandolph 74 Solar [ UX _ Signing Official & Title:L. Wayne Marshall Manager b. Contact information for person listed in item 1a above: Street Add ress:1 1330 Vanstory Drive Suite 101 City:Huntersville Mailing Address (if applicable):Same City: Phone: (919 } 897-0713 Email: wrnarshail@liep-pgtra.com State:NC State: Fax: Zip:28078 Zip: Please check the appropriate box. The applicant listed above is. - The property owner (Skip to Contact Information, item 3a) ® Lessee* (Attach a copy of the lease agreement and complete Contact Information, item 2a and 2b below) ❑ Purchaser* (Attach a copy of the pending sales agreement and complete Contact Information, item 2a and 2b below) ❑ Developer* (Complete Contact Information, item 2a and 2b below.) 2. a. Print Property Owner's name and title below, if you are the lessee, purchaser or developer. (This is the person who owns the property that the project is located on): Property Owner/ Organization: Heelstone Land HoldingE LLC Signing Official & Title:Dustin b. Contact information for person listed in item 2a above: Street Address:5949 Sherry Lane Suite 550 City:Dallas State:TX Zip:75225 Mailing Address (if applicable).Same City: State: Zip:, Phone: Fax: ( „� Email: d inn@sammonsinfrastructure.com 3. a. (Optional) Print the name and title of another contact such as the project's construction supervisor or other person who can answer questions about the project: Other Contact Person/Organization:he -Petra Construction Signing Official & Title:Greg Peterson President b. Contact information for person listed in item 3a above: Mailing Address:11330 Vanstory Drive, Suite 101 C i ty: Hu ntersville State:NC Z i p:28078 Phone: (919 ) 961-1640 Fax: Email:gpeterson@hel2-12etra.COM 4. Local jurisdiction for building permits: City of Shelby Point of Contact:Clint White Phone #:.(704 } 484-6805 Form SWU-101 Version Oct. 31, 2013 Page 2 of 6 IV. PROJECT INFORMATION 1. In the space provided below, briefly summarize how the stormwater runoff will be treated. Since the project is low density, there will be no permanent constructed stormwater control measures. The site will com lv with the design elements specified in Parts E-1 and E-6 of the Stormwater Design manual, to include the use of ve eataed swalespanel separation re uirements and other design criteria mentioned. 2. a. If claiming vested rights, identify the supporting documents provided and the date they were approved: ❑ Approval of a Site Specific Development Plan or PUD Approval Date: ❑ Valid Building Permit Issued Date: ❑ Other: Date: b.If claiming vested rights, identify the regulation(s) the project has been designed in accordance with: ❑ Coastal SW - 1995 ❑ Ph II - Post Construction 3. Stormwater runoff from this project drains to the Broad River basin. 4. Total Property Area: 26.58 acres 5. Total Coastal Wetlands Area: 0 acres 6. Total Surface Water Area: 0 acres 7. Total Property Area (4) - Total Coastal Wetlands Area (5) - Total Surface Water Area (6) = Total Project Area+:26.58 acres + Total project urea shall be calculated to exclude the folloroing: the normal pool of impounded structures, the area between the banks of streams and rivers, the area below the Normal High Water (NNW) line or Mean High Water (Ml-1W) line, and coastal wetlands landward froin the NHW (or MHW) line, The resultant project area is used to calculate overall percent built upon area (BUA). Non -coastal wetlands landward of the NHW (or MHW) tine )ray be included in the total project area. 8. Project percent of impervious area: (Total Impervious Area / Total Project Area) X 100 = 15.50 % 10 How many drainage areas does the project have?1 (For high density, count I for each proposed engineered Stormwater BMP. For lots? density and other projects, use I for the whole property area) Complete the following information for each drainage area identified in Project Information item 9. If there are more than four drainage areas in the project, attach an additional sheet with the information for each area provided in the same format as below. ��icuin ��u55 unu inuex ivumver can ee determined at: Frei : -tell.1acdennor 'roc b i�C �S L'5P! CiaSSi [cattioYts Impervious area is defined as the built upon area including, but not limited to, buildings, roads, parking areas, sidewalks, gravel areas, etc. Form SWU-101 Version Oct. 31, 2013 Page 3 of 6 'Report only that amount of existing BUA that will remain after development. Do not report any existing BUA that is to be removed and which will be replaced by new BUA. 11. How was the off -site impervious area listed above determined? Provide documentation. N/A Proiects in Union Countv,: Contact DEMLR Central Office staff to check if the project is located within a Threatened & Endangered Species watershed that may be subject to more stringent stormwater requirements as per 15A NCAC 02B .0600. V. SUPPLEMENT AND O&M FORMS The applicable state stormwater management permit supplement and operation and maintenance (O&M) forms must be submitted for each BMP specified for this project. The latest versions of the forms can be downloaded from htt�,://}2ortal.ncdenr.org/",eb/wgIws/su/br»p-manual. VI. SUBMITTAL REQUIREMENTS Only complete application packages will be accepted and reviewed by the Division of Energy, Mineral and Land Resources (DEMLR). A complete package includes all of the items listed below. A detailed application instruction sheet and BMP checklists are available from [iLtl2://12oi-tal.tictieiir.org/web/wq/ws/`su/statesw./fornis clots. The complete application package should be submitted to the appropriate DEMLR Office. (The appropriate office may be found by locating project on the interactive online map at .) Please indicate that the following required information have been provided by initialing in the space provided for each item. All original documents MUST be signed and initialed in blue ink. Download the latest versions for each submitted application package from http;//porta1.nc(lenr.org/web/wq/ws/su/statesw/forms flocs. Initials 1. Original and one copy of the Stormwater Management Permit Application Form. f m w 2. Original and one copy of the signed and notarized Deed Restrictions & Protective Covenants IVA Form. (if required as per Part VII below) 3. Original of the applicable Supplement Form(s) (sealed signed and dated) and O&M agreement(s) for each BMP. 4. Permit application processing fee of $505 payable to NCDENR. (For an Express review, refer to httl2://www.envheIR.org/12a&es/­onestopexpresg.html for information on the Express program and the associated fees. Contact the appropriate regional office Express Permit Coordinator for additional information and to schedule the required application meeting.) 5. A detailed narrative (one to two pages) describing the stormwater treatment/management 6. A USGS map identifying the site location. If the receiving stream is reported as class SA or the receiving stream drains to class SA waters within 1/2 mile of the site boundary, include the 1/2 mile radius on the map. 7. Sealed, signed and dated calculations (one copy). 8. Two sets of plans folded to 8.5" x 14" (sealed, signed, & dated), including: a. Development/Project name. b. Engineer and firm. c. Location map with named streets and NCSR numbers. d. Legend. e. North arrow. f. Scale. g. Revision number and dates. h. Identify all surface waters on the plans by delineating the normal pool elevation of impounded structures, the banks of streams and rivers, the MHW or NHW line of tidal waters, and any coastal wetlands landward of the MHW or NHW lines. • Delineate the vegetated buffer landward from the normal pool elevation of impounded structures, the banks of streams or rivers, and the MHW (or NHW) of tidal waters. i. Dimensioned property/project boundary with bearings & distances. j. Site Layout with all BUA identified and dimensioned. k. Existing contours, proposed contours, spot elevations, finished floor elevations. 1. Details of roads, drainage features, collection systems, and stormwater control measures. m. Wetlands delineated, or a note on the plans that none exist. (Must be delineated by a qualified person. Provide documentation of qualifications and identify the person who made the determination on the plans. n. Existing drainage (including off -site), drainage easements, pipe sizes, runoff calculations. o. Drainage areas delineated (included in the main set of plans, not as a separate document). PI' d MN for PM1✓ PhA/ Pn ti /h A/ Form SWU-101 Version Oct. 31, 2013 Page 4 of 6 p. Vegetated buffers (where required). 9. Copy of any applicable sails report with the associated SHWT elevations (Please identify M NJ elevations in addition to depths) as well as a map of the boring locations with the existing elevations and boring logs. Include an 8.5"xl1" copy of the MRCS County Soils map with the project area clearly delineated. For projects with infiltration BMPs, the report should also include the soil type, expected infiltration rate, and the method of determining the infiltration rate. (Infiltration Devices submitted to WiRO: Schedule a site visit.for DEMLR to verif:l the SHWI' prior to submittal, (910) 796-7378.) 10. A copy of the most current property deed. Deed book: 1695 Page No: 871 PMnI 11. For corporations and limited liability corporations (LLC): Provide documentation from the NC em N Secretary of State or other official documentation, which supports the titles and positions held by the persons listed in Contact Information, item 1a, 2a, and/or 3a per 15A NCAC 2H.1003(e). The corporation or LLC must be listed as an active corporation in good standing with the NC Secretary of State, otherwise the application will be returned. htW://www.secretary.state.nc.us/Corl2orations/CSearch.asl2x VII. DEED RESTRICTIONS AND PROTECTIVE COVENANTS For all subdivisions, outparcels, and future development, the appropriate property restrictions and protective covenants are required to be recorded prior to the sale of any lot. If lot sizes vary significantly or the proposed BUA allocations vary, a table listing each lot number, lot size, and the allowable built -upon area must be provided as an attachment to the completed and notarized deed restriction form. The appropriate deed restrictions and protective covenants forms can be downloaded from http://portaI.ncdei-Lr.org web tr state- stormwater-forms does. Download the latest versions for each submittal. In the instances where the applicant is different than the property owner, it is the responsibility of the property owner to sign the deed restrictions and protective covenants form while the applicant is responsible for ensuring that the deed restrictions are recorded. By the notarized signature(s) below, the permit holder(s) certify that the recorded property restrictions and protective covenants for this project, if required, shall include all the items required in the permit and listed on the forms available on the website, that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, that the required covenants cannot be changed or deleted without concurrence from the NC DEMLR, and that they will be recorded prior to the sale of any lot. VIII. CONSULTANT INFORMATION AND AUTHORIZATION Applicant: Complete this section if you wish to designate authority to another individual and/or firm (such as a consulting engineer and/or firm) so that they may provide information on your behalf for this project (such as addressing requests for additional information). Consulting Engineer:Patrick Needham PE Consulting Firm: McKim & Creed Mailing Address:8020 Tower Point Drive City:CharIotte Phone: 704 841-2588 F,maii:12needham@mckimcreed.com State: NC Zip:28227 Fax: (704 ) 841-2567 IX. PROPERTY OWNER AUTHORIZATION (if Contact Information, item 2 has been filled out, complete this section) I, (print or type name of person listed in Contact Information, item 2a) Dustin Guilin ; certify that I own the property identified in this permit application, and thus give permission to (print or hype name of person listed in Contact Information, item 1a) L. Wayne Marshall with (print or hjpe name of organization listed in Contact Information, item 1a) 233 Randolph 74 Solar 1, LLC to develop the project as currently proposed. A copy of the lease agreement or pending property sales contract has been provided with the submittal, which indicates the party responsible for the operation and maintenance of the stormwater system. Form SWU-101 Version Oct. 31, 2013 Page 5 of 6 As the legal property owner I acknowledge, understand, and agree by my signature below, that if my designated agent (entity listed in Contact Information, item 1) dissolves their company and/or cancels or defaults on their lease agreement, or pending safe, responsibility for compliance with the DEMLR Stormwater permit reverts back to me, the property owner. As the property owner, it is my responsibility to notify DEMLR immediately and submit a completed Name/Ownership Change Form within 30 days; otherwise I will be operating a stormwater treatment facility without a valid permit. I understand that the operation of a stormwater treatment facility without a valid permit is a violation of NC General Statue 143-215.1 and may result in appropriate enforcement action including the assessment of civil penalties of up to $25,000 per day, pursuant to NCGS 143-215.6. Signature: Date:. I, G1 �I ore �'� a Notary Public for the State of TOA S _ County of do herebycertify that u5-hti 1—..(4E4u mv� ' t fy personally appeared before me this "I day of Maya % Sal , and acknowledge the due execution of the application for a stormwater permit. Witness my hand and official seal, �" IV- P` �7+ �,,+'r'P "■,, HALIEE NICOLE PRITCHETT IC # 13225514-7 Rotary Public, State of Texas t= My Commission EApires -,�•''�pF, .' 11/15/2023 X. APPLICANT'S CERTIFICATION SEAL My commission expires 1 I ((S I2-0Z3 1, (print or type name of person listed in Contact Information, item 1a) Wayne Marshall certify that the information included on this permit application form is, to the best of my knowledge, correct and that the project will be constructed in conformance with the approved plans, that the required deed restrictions and protective covenants will be recorded, and that the proposed project complies with the requirements of the applicable stormwater Yes under 1 A NCAC 2H .1000 and any other applicable state stormwater requirements. Signature: 114111 Date: 12-1202-I I, 6" / / d a , a Notary Public for the State of NDi' , Conit'rliq County of do hereby certify that L W6Z 1'W MarSh 11 personally appeared before me this r12( stormwater permit. day of lVia-'C op7 9� and acknowledge the due execution of the application for a Witness my hand and official seal, 6 I I X�ku411 I I i 11 m ��,..` .410 P, V 1l.L,�/V1 MY z COAAMISSIPfil EXPIRES SM 30441022 z1 UBLI G�N,•� SEAL My commission expires ailso� Form SWU-101 Version Oct. 31, 2013 Page 7 of 7