Loading...
HomeMy WebLinkAboutSW5200201_Plan (Grading)_20200413241241 241 241 2412412412412402402402 4 0 240 241 241 24 0 2 4 0 238 23 9 2 3 9 239 239238238 2382392 3 9239240240240239241 2 4 2 242 240 240241241241242 238238237238238237 238238236 2362 3 8 2 3 7 237239EX. 20' ALLEY OR STREET(FORMERLY MANN STREET)PB 70 PG 304EXISTING 66' PUBLIC R/W ELM STREET EXISTING 66' PUBLIC R/W MARKET STREET EXISTING 66' PUBLIC R/WBROCKLYN STREETXXXXXXXXXXXX X X X X X X X XXXX X X X X X X XXX X XXXXX XXXXXXX X X X X X X X X X X X X X X X X X X X XXXXXXXXX X X X X XS55°15'33"E300.41'N34°28'18"E 642.01' PINE PINE PINE OAK OAK PINE PINE PINE PINE PINE PINE PICNIC SHELTER PICNIC SHELTER PLAY AREA ASPHALT A S P H A L T T R A C K S EX. YI 6EX. 15" HDPE S S EX. YI 7 SDMH N55°15'33"W297.39'N34°45'04"E 642.00' N34°45'04"E 679.08' YI# 101 YI# 100 53 LF 15" RCP @ 0.40% FG 240.60 FG 240.70 EP 241.05 +/- EP 239.85 +/- EP 238.50 +/- EP 238.48 +/-EP 238.30 +/-EP 238.20 +/- FG 238.00FG 238.10FG 238.00 FG 238.25 FG 238.25FG 238.20FG 238.10FG 239.30FG 239.50 MATCH EX.MATCH EX.MATCH EX. MATCH EX. MATCH EX. MATCH EX. FG 236.30 FG 239.20 FG 237.85241240 239 240 239 238 241 240 239 240 23 9 238 237 238 2 4 1 238240239 2 3 9 2 4 0 EX. STORM PIPE 325.90 LF @ 0.092% (MATERIALS UNKNOWN) NOTE: SURVEY DATA FOR THE EXISTING PIPE UNDER THE MULTIPURPOSE FIELDS IS INCONCLUSIVE AND SHOULD BE CONSIDERED APPROXIMATE IN NATURE. THE CONDITION AND CAPACITY OF THE EXISTING PIPE ARE UNABLE TO BE ADEQUATELY DETERMINED BY THE AVAILABLE DATA. EXISTING INLET TOP 239.23 INV. IN 233.55 (S) INV. IN 233.37 (N) BOTTOM MH 233.15 LIMITS OF DISTURBANCE (REFER TO EROSION CONTROL PLAN ) LIMITS OF DISTURBANCE (REFER TO EROSION CONTROL PLAN ) SPOT ELEVATION MAJOR CONTOUR MINOR CONTOUR 400400400 FLOW DIRECTION4.0% LIMITS OF DISTURBANCE FG 387.46 402 RIP-RAP OUTLET PROTECTION SPOT ELEVATION MAJOR CONTOUR MINOR CONTOUR 400400400 FLOW DIRECTION4.0% LIMITS OF DISTURBANCE FG 387.46 402 RIP-RAP OUTLET PROTECTION STORM DRAINAGE TABLE INLET# 100 101 TYPE YI YI RIM ELEV (EOP) 236.50 236.30 INV IN (FROM-SIZE) 232.66 (101-15") INV OUT (TO-SIZE) 232.87 (100-15")N30'60' SCALE IN FEET 15'30' SCALE: 1 IN = 30 FT SCALE IN FEET HORIZONTAL 0 THESE PLANS AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF SHIPMAN ENGINEERING, PLLC AND MAY NOT BE REPRODUCED IN WHOLE OR IN PART. THESE DOCUMENTS SHALL NOT BE USED FOR ANY PURPOSEWHATSOEVER, INCLUDING, BUT NOT LIMITED TO, CONSTRUCTION, BIDDING, AND/OR CONSTRUCTION STAKING WITHOUT THE EXPRESS WRITTEN CONSENT OF SHIPMAN ENGINEERING, PLLC.REVISIONSSYMBOLDATE137 MIDDLEGREEN PLACEHOLLY SPRINGS, NC 27540NCBELS LICENSE P-1963DESIGNED BY:WZS DRAWN BY:WZS CHECKED BY:WZS DRAWING DATE: SE PROJECT #:LEE STREET ATHLETICCOMPLEX IMPROVEMENTSTOWN OF BENSONJOHNSTON COUNTY, NORTH CAROLINASHEET NUMBER: 2019-017SHIPMANENGINEERING 919.900.0006SHIPMAN ENGINEERING, PLLC07-11-19103-12-2020PER NCDEQ EROSION CONTROL COMMENTS204-7-2020PER DWQ STORMWATER COMMENTSC-07 PARTIAL GRADING & DRAINAGE PLAN IGRADING & DRAINAGE LEGEND ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH TOWN OF BENSON STANDARDS AND SPECIFICATIONS. MATCHLINE REFER TO C-08 GRADING AND DRAINAGE NOTES: 1.BEFORE YOU DIG, STOP. CALL THE NC ONE-CALL CENTER AT 1-800-632-4949. IT'S THE LAW. EXISTING UTILITIES ARE SHOWN FROM THE BEST AVAILABLE INFORMATION AND ARE APPROXIMATE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THESE AND OTHER UTILITIES BEFORE STARTING CONSTRUCTION. NOTIFY UTILITY LOCATING COMPANY (ONE CALL @ 1-800-632-4949) OR INDIVIDUAL UTILITY OWNERS FOR UNDERGROUND LOCATIONS AT LEAST 48 HOURS IN ADVANCE. 2.ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE TOWN OF BENSON STANDARD SPECIFICATIONS AND DETAILS. 3.EXISTING CONDITIONS AND TOPOGRAPHICAL DATA OF THE SUBJECT PARCEL ARE COMPILED FROM A FIELD SURVEY OF THE PROPERTY BY LAMBERT SURVEYING, INC. (DATED APRIL 5, 2019) AND IS NOT THE RESULT OF A FIELD SURVEY BY SHIPMAN ENGINEERING, PLLC. ADDITIONAL EXISTING CONDITIONS DATA PROVIDED BY SUPPLEMENTAL DATA INCLUDING AERIAL PHOTOGRAPHY, JOHNSTON COUNTY GIS DATA, AND OTHER DATA SOURCES AS REQUIRED. 4.RIPARIAN BUFFER AREAS SHALL NOT BE CLEARED, DRAINAGE, OR OTHERWISE DISTURBED UNLESS SPECIFICALLY PERMITTED BY THE US ARMY CORPS OF ENGINEERS AND NCDENR-DWQ. 5.TREE PROTECTION FENCING SHALL BE PROVIDED ALONG ALL VEGETATED RIPARIAN AND VEGETATED PERIMETER BUFFER AREAS AS WELL AS TREE CONSERVATION AREAS. 6.20' STORM EASEMENTS SHALL BE CENTERED ON ALL STORM SEWER PIPE LOCATED OUTSIDE OF STREET RIGHT OF WAYS. 7.UTILITY PIPE SIZES & LOCATIONS ARE PRELIMINARY AND SHALL BE FINALIZED DURING CONSTRUCTION DRAWING REVIEW & APPROVAL. 8.ALL STORM DRAINAGE WITHIN THE RIGHT OF WAY SHALL BE PUBLIC. ALL STORM DRAINAGE OUTSIDE THE RIGHT OF WAY SHALL BE PRIVATE. 9.STORM DRAINAGE PIPING SHALL BE CLASS III RCP UNLESS OTHERWISE NOTED. STORM DRAINAGE WITH LESS THAN 2' OF COVER MEASURED FROM SUBGRADE SHALL BE CLASS IV RCP. 10.PRIVATE UTILITIES (POWER, TELEPHONE, NATURAL GAS, CABLE TV) ARE NOT SHOWN ON THIS PLAN. THE CONTRACTOR SHALL COORDINATE THE INSTALLATION OF THOSE UTILITIES WHEN INSTALLING STORM DRAINAGE TO AVOID CONFLICTS. 11.RIM ELEVATION FOR YARD INLETS (YI) REFERS TO THE CENTER OF THE TOP OF GRATE. RIM ELEVATION OF MANHOLES (SDMH) REFERS TO THE CENTER OF THE TOP OF MANHOLE COVER. TOP ELEVATION OF CATCH BASINS (CB) REFERS TO THE CENTER OF THE TOP OF CASTING ELEVATION. 12.PROPOSED CONTOURS ILLUSTRATE THE FINISHED SURFACE ELEVATION FOR PAVEMENT, FINISHED SUBGRADE ELEVATION IN OPEN AREAS AND TOP OF RIP-RAP UNLESS OTHERWISE NOTED. 13.CUT/FILL SLOPES SHALL BE GRADED AT A MAXIMUM OF 3H:1V UNLESS OTHERWISE INDICATED. 14.NO GRADING EQUIPMENT SHALL BE PERMITTED ON-SITE UNTIL A GRADING PERMIT HAS BEEN ISSUED BY JOHNSTON COUNTY AND/OR NCDEQ DIVISION OF LAND QUALITY. 15.ALL RIP-RAP IS TO BE INSTALLED WITH NON-WOVEN FILTER FABRIC BENEATH (MIRAFI 140N OR APPROVED EQUAL). 16.WHERE PROPOSED EDGE OF PAVEMENT CONNECTS TO EXISTING, CONTRACTOR SHALL MATCH EXISTING ELEVATION AND CREATE A SMOOTH TRANSITION. 17.CONTRACTOR SHALL RAISE ALL STRUCTURES TO FINISHED GRADE ELEVATIONS. ACCESSIBILITY GRADING NOTES: 1.ALL CONCRETE SIDEWALK AND PEDESTRIAN AREAS WITHIN THE PROJECT BOUNDARY SHALL COMPLY WITH ADA ACCESSIBILITY REQUIREMENTS. 2.THE MAXIMUM SIDEWALK CROSS SLOPE SHALL BE 2%. THE MAXIMUM SIDEWALK RUNNING SLOPE SHALL BE 5% 3.CONTACT DESIGN ENGINEER SHOULD DISCREPANCIES BE FOUND WITH REGARD TO MATCHING THE EXISTING SIDEWALK GRADES. 241241241241241241 241 241 240 2402402 4 0240 238 23 9 239239239239 239 239239242240 241 2 3 9 239 EXISTING 60' PUBLIC R/W LEE STREETEXISTING PUBLIC R/WMANN STREETX X X X X X X X X X XXXXXXXXXXXX X X X XXXXXXXXXXXXXXXXXXX XXXXXXX X XXXXXXXXXXXXXXXX X X X X X X X X X X X X X X X X X X X XFMR XFMR X X X X EX. DUGOUT EX. DUGOUTEX. DUGOUTEX. DUGOUTASPHALT TRACK ASPHALT CONC. S/W CONC. S/WCONC. S/W EX. CHAIN LINK FENCE EX. CHAIN LINK FENCE EX. CHAIN LINK FENCE WMS EX. 15" HDPE EX. 1 5" H D P E E X . 1 5 " H D P EEX. 15" HDPEEX. YI 1 EX. YI 2 EX. YI 3 EX. YI 4 S N55°15'33"W629.49'S34°43'27"W 1237.44'XXXXXX XXXX X X XXXXXXXXXXXX X X X X X X X X X XXX XXXX X XXXXXX X X X X X X X X X X XXXXXXXXXXXXXXXXXXXXX XX X X X X X X X X X X X X X X X X X X X X X X X XXXXXXXXXXXXXXXX XXX WWSAN SAN SAN SAN SAN SAN FM FMFMFMFMFMFMFM FM FM FM FM FM FM FM FM FM FM FM FM RPZWM10+00 11+0012+00 13+00 14+00 14+75 WWWWWWWWWWWWWWWWWPROPOSED FIELD HOUSE FFE= 240.30 FG 240.15 FG 240.00 FG 240.10 FG 239.85 FG 239.40 +/- FG 239.00 FG 239.10 FG 239.60 FG 239.75 FG 239.30 +/- FG 239.40 +/- FG 240.05 FG 240.00 FG 240.30 FG 240.00 FG 240.45 FG 240.10 FG 239.50 +/- MATCH EX. MATCH EX. MATCH EX. MATCH EX. FG 239.50 FG 239.80 FG 240.30 FG 240.10FG 240.30 FG 240.10 FG 240.20 240 2 4 1 240 240 239239239FG 240.10 LIMITS OF DISTURBANCE (REFER TO EROSION CONTROL PLAN ) LIMITS OF DISTURBANCE (REFER TO EROSION CONTROL PLAN ) FG 239.70 FG 238.81 FG 239.61 FG 239.60 FG 239.40 FG 239.80 FG 239.76 DRAINAGE SWALE MIN. SLOPE 0.5% DRAINAGE SWALE MIN. SLOPE 0.5% (CONTRACTOR SHALL ENSURE POSITIVE DRAINAGE AWAY FROM BUILDING INTO EX. YARD INLET)2402 4 0 SPOT ELEVATION MAJOR CONTOUR MINOR CONTOUR 400400400 FLOW DIRECTION4.0% LIMITS OF DISTURBANCE FG 387.46 402 RIP-RAP OUTLET PROTECTION SPOT ELEVATION MAJOR CONTOUR MINOR CONTOUR 400400400 FLOW DIRECTION4.0% LIMITS OF DISTURBANCE FG 387.46 402 RIP-RAP OUTLET PROTECTION STORM DRAINAGE TABLE INLET# 100 101 TYPE YI YI RIM ELEV (EOP) 236.50 236.30 INV IN (FROM-SIZE) 232.66 (101-15") INV OUT (TO-SIZE) 232.87 (100-15")N30'60' SCALE IN FEET 15'30' SCALE: 1 IN = 30 FT SCALE IN FEET HORIZONTAL 0 THESE PLANS AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF SHIPMAN ENGINEERING, PLLC AND MAY NOT BE REPRODUCED IN WHOLE OR IN PART. THESE DOCUMENTS SHALL NOT BE USED FOR ANY PURPOSEWHATSOEVER, INCLUDING, BUT NOT LIMITED TO, CONSTRUCTION, BIDDING, AND/OR CONSTRUCTION STAKING WITHOUT THE EXPRESS WRITTEN CONSENT OF SHIPMAN ENGINEERING, PLLC.REVISIONSSYMBOLDATE137 MIDDLEGREEN PLACEHOLLY SPRINGS, NC 27540NCBELS LICENSE P-1963DESIGNED BY:WZS DRAWN BY:WZS CHECKED BY:WZS DRAWING DATE: SE PROJECT #:LEE STREET ATHLETICCOMPLEX IMPROVEMENTSTOWN OF BENSONJOHNSTON COUNTY, NORTH CAROLINASHEET NUMBER: 2019-017SHIPMANENGINEERING 919.900.0006SHIPMAN ENGINEERING, PLLC07-11-19103-12-2020PER NCDEQ EROSION CONTROL COMMENTS204-7-2020PER DWQ STORMWATER COMMENTSC-08 PARTIAL GRADING & DRAINAGE PLAN IIALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH TOWN OF BENSON STANDARDS AND SPECIFICATIONS. MATCHLINE REFER TO C-07 GRADING & DRAINAGE LEGEND GRADING AND DRAINAGE NOTES: 1.BEFORE YOU DIG, STOP. CALL THE NC ONE-CALL CENTER AT 1-800-632-4949. IT'S THE LAW. EXISTING UTILITIES ARE SHOWN FROM THE BEST AVAILABLE INFORMATION AND ARE APPROXIMATE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THESE AND OTHER UTILITIES BEFORE STARTING CONSTRUCTION. NOTIFY UTILITY LOCATING COMPANY (ONE CALL @ 1-800-632-4949) OR INDIVIDUAL UTILITY OWNERS FOR UNDERGROUND LOCATIONS AT LEAST 48 HOURS IN ADVANCE. 2.ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE TOWN OF BENSON STANDARD SPECIFICATIONS AND DETAILS. 3.EXISTING CONDITIONS AND TOPOGRAPHICAL DATA OF THE SUBJECT PARCEL ARE COMPILED FROM A FIELD SURVEY OF THE PROPERTY BY LAMBERT SURVEYING, INC. (DATED APRIL 5, 2019) AND IS NOT THE RESULT OF A FIELD SURVEY BY SHIPMAN ENGINEERING, PLLC. ADDITIONAL EXISTING CONDITIONS DATA PROVIDED BY SUPPLEMENTAL DATA INCLUDING AERIAL PHOTOGRAPHY, JOHNSTON COUNTY GIS DATA, AND OTHER DATA SOURCES AS REQUIRED. 4.RIPARIAN BUFFER AREAS SHALL NOT BE CLEARED, DRAINAGE, OR OTHERWISE DISTURBED UNLESS SPECIFICALLY PERMITTED BY THE US ARMY CORPS OF ENGINEERS AND NCDENR-DWQ. 5.TREE PROTECTION FENCING SHALL BE PROVIDED ALONG ALL VEGETATED RIPARIAN AND VEGETATED PERIMETER BUFFER AREAS AS WELL AS TREE CONSERVATION AREAS. 6.20' STORM EASEMENTS SHALL BE CENTERED ON ALL STORM SEWER PIPE LOCATED OUTSIDE OF STREET RIGHT OF WAYS. 7.UTILITY PIPE SIZES & LOCATIONS ARE PRELIMINARY AND SHALL BE FINALIZED DURING CONSTRUCTION DRAWING REVIEW & APPROVAL. 8.ALL STORM DRAINAGE WITHIN THE RIGHT OF WAY SHALL BE PUBLIC. ALL STORM DRAINAGE OUTSIDE THE RIGHT OF WAY SHALL BE PRIVATE. 9.STORM DRAINAGE PIPING SHALL BE CLASS III RCP UNLESS OTHERWISE NOTED. STORM DRAINAGE WITH LESS THAN 2' OF COVER MEASURED FROM SUBGRADE SHALL BE CLASS IV RCP. 10.PRIVATE UTILITIES (POWER, TELEPHONE, NATURAL GAS, CABLE TV) ARE NOT SHOWN ON THIS PLAN. THE CONTRACTOR SHALL COORDINATE THE INSTALLATION OF THOSE UTILITIES WHEN INSTALLING STORM DRAINAGE TO AVOID CONFLICTS. 11.RIM ELEVATION FOR YARD INLETS (YI) REFERS TO THE CENTER OF THE TOP OF GRATE. RIM ELEVATION OF MANHOLES (SDMH) REFERS TO THE CENTER OF THE TOP OF MANHOLE COVER. TOP ELEVATION OF CATCH BASINS (CB) REFERS TO THE CENTER OF THE TOP OF CASTING ELEVATION. 12.PROPOSED CONTOURS ILLUSTRATE THE FINISHED SURFACE ELEVATION FOR PAVEMENT, FINISHED SUBGRADE ELEVATION IN OPEN AREAS AND TOP OF RIP-RAP UNLESS OTHERWISE NOTED. 13.CUT/FILL SLOPES SHALL BE GRADED AT A MAXIMUM OF 3H:1V UNLESS OTHERWISE INDICATED. 14.NO GRADING EQUIPMENT SHALL BE PERMITTED ON-SITE UNTIL A GRADING PERMIT HAS BEEN ISSUED BY JOHNSTON COUNTY AND/OR NCDEQ DIVISION OF LAND QUALITY. 15.ALL RIP-RAP IS TO BE INSTALLED WITH NON-WOVEN FILTER FABRIC BENEATH (MIRAFI 140N OR APPROVED EQUAL). 16.WHERE PROPOSED EDGE OF PAVEMENT CONNECTS TO EXISTING, CONTRACTOR SHALL MATCH EXISTING ELEVATION AND CREATE A SMOOTH TRANSITION. 17.CONTRACTOR SHALL RAISE ALL STRUCTURES TO FINISHED GRADE ELEVATIONS. ACCESSIBILITY GRADING NOTES: 1.ALL CONCRETE SIDEWALK AND PEDESTRIAN AREAS WITHIN THE PROJECT BOUNDARY SHALL COMPLY WITH ADA ACCESSIBILITY REQUIREMENTS. 2.THE MAXIMUM SIDEWALK CROSS SLOPE SHALL BE 2%. THE MAXIMUM SIDEWALK RUNNING SLOPE SHALL BE 5% 3.CONTACT DESIGN ENGINEER SHOULD DISCREPANCIES BE FOUND WITH REGARD TO MATCHING THE EXISTING SIDEWALK GRADES.