HomeMy WebLinkAboutSW3200201_Plan (Misc. Detail)_202002121 C902 TEMPORARY GRAVEL CONSTRUCTION ENTRANCE GENERAL NOTES: 1. A STABILIZED ENTRANCE PAD OF COARSE AGGREGATE OR RAILROAD BALLAST SHOULD BE LOCATED WHERE TRAFFIC WILL ENTER OR LEAVE THE CONSTRUCTION SITE ONTO A PUBLIC STREET. 2. FILTER FABRIC OR COMPACTED CRUSHER RUN STONE SHOULD BE USED AS A BASE FOR THE CONSTRUCTION ENTRANCE. 3. THE ENTRANCE SHOULD BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR FLOWING OF SEDIMENT ONTO PUBLIC STREETS OR EXISTING PAVEMENT. THE MAY REQUIRE PERIODIC TOP DRESSING WITH ADDITIONAL STONE AS CONDITIONS WARRANT AND REPAIR OR CLEANOUT OF ANY MEASURES USED TO TRAP SEDIMENT. 4. ANY SEDIMENT SPILLED, DROPPED, WASHED, OR TRACKED ONTO PUBLIC STREETS MUST BE REMOVED IMMEDIATELY. 5. WHEN APPROPRIATE, WHEELS MUST BE CLEANED TO REMOVE SEDIMENT PRIOR TO ENTERING A PUBLIC STREET. WHEN WASHING IS REQUIRED, IT SHOULD BE DONE IN AN AREA STABILIZED WITH CRUSHED STONE WHICH DRAINS INTO AN APPROVED SEDIMENT BASIN. 6. CDOT MAY REQUIRE A STANDARD COMMERCIAL DRIVEWAY TO ACCESS THE CONSTRUCTION SITE IF THE DRIVEWAY IS ON A THROUGHFARE. 7. PLEASE REFER TO NCESCPDM SECTION #6.06 FOR ADDITIONAL DESIGN SPECIFICATIONS REGARDING TEMPORARY GRAVEL CONSTRUCTION ENTRANCES/EXITS. MAINTENANCE NOTES: MAINTAIN THE GRAVEL PAD IN A CONDITION TO PREVENT MUD OR SEDIMENT FROM LEAVING THE CONSTRUCTION SITE. THIS MAY REQUIRE PERIODIC TOPDRESSING WITH 2-INCH STONE. AFTER EACH RAINFALL, INSPECT ANY STRUCTURE USED TO TRAP SEDIMENT AND CLEAN IT OUT AS NECESSARY. IMMEDIATELY REMOVE ALL OBJECTIONABLE MATERIALS SPILLED, WASHED, OR TRACKED ONTO PUBLIC ROADWAYS. 4 C902 3 X Do EXISTING GROUN 50' MIN 6" MIN PUBLIC STREET SOIL STABILIZATION FABRIC UNDER 2-3" COARSE AGGREGATE LL LL U J m STANDARD PIPE OUTLET MINIMUM_ TAILWATER GENERAL NOTES: 1. LA = THE LENGTH OF THE RIPRAP APRON. 2. d = 1.5 TIMES THE MAXIMUM STONE DIAMETER BUT NOT LESS THAN 6" (INCHES). 3. A FILTER BLANKET OR FILTER FABRIC SHOULD BE INSTALLED BETWEEN THE RIPRAP AND SOIL FOUNDATION. MAINTENANCE NOTES: W = Do+ LA INSPECT RIPRAP OUTLET STRUCTURES WEEKLY AND AFTER SIGNIFICANT (1/2 INCH OR GREATER) RAINFALL EVENTS TO SEE IF ANY EROSION AROUND OR BELOW THE RIPRAP HAS TAKEN PLACE, OR IF STONES HAVE BEEN DISLODGED. IMMEDIATELY MAKE ALL NEEDED REPAIRS TO PREVENT FURTHER DAMAGE. z C902 8' MAX WIRE F-EmIN '^ WOVEN FILTER FABF SILT FENCE GENERAL NOTES: 1. USE A SYNTHETIC FILTER FABRIC OF AT LEAST 950/c BY WEIGHT OF POLYOLEFINS OR POLYESTER, WHICH IS CERTIFIED BY THE MANUFACTURER OR SUPPLIER AS CONFORMING TO THE REQUIREMENTS IN ASTM D 6461, WHICH IS SHOWN IN PART IN TABLE 6.62b. 2. SYNTHETIC FILTER FABRIC SHOULD CONTAIN ULTRAVIOLET RAY INHIBITORS AND STABILIZERS TO PROVIDE A MINIMUM OF 6 MONTHS OF EXPECTED USABLE CONSTRUCTION LIFE AT A TEMPERATURE RANGE OF 0 TO 120• F. 3. ENSURE THAT POSTS FOR SEDIMENT FENCES ARE 1.25 LB/LINEAR FT MINIMUM STEEL WITH A MINIMUM LENGTH OF 5 FEET. MAKE SURE THAT STEEL POSTS HAVE PROJECTIONS TO FACILITATE FASTENING THE FABRIC. 4. FOR REINFORCEMENT OF STANDARD STRENGTH FILTER FABRIC, USE WIRE FENCE WITH A MINIMUM 14 GAUGE AND A MAXIMUM MESH SPACING OF 6 INCHES. 5. CONSTRUCT THE SEDIMENT BARRIER OF STANDARD STRENGTH OR EXTRA STRENGTH SYNTHETIC FILTER FABRICS. 6. ENSURE THAT THE HEIGHT OF THE SEDIMENT FENCE DOES NOT EXCEED 24 INCHES ABOVE THE GROUND SURFACE. (HIGHER FENCES MAY IMPOUND VOLUMES OF WATER SUFFICIENT TO CAUSE FAILURE OF THE STRUCTURE.) 7. CONSTRUCT THE FILTER FABRIC FROM A CONTINUOUS ROLL CUT TO THE LENGTH OF THE BARRIER TO AVOID JOINTS. WHEN JOINTS ARE NECESSARY, SECURELY FASTEN THE FILTER CLOTH ONLY AT A SUPPORT POST WITH 4 FEET MINIMUM OVERLAP TO THE NEXT POST. 8. SUPPORT STANDARD STRENGTH FILTER FABRIC BY WIRE MESH FASTENED SECURELY TO THE UPSLOPE SIDE OF THE POSTS. EXTEND THE WIRE MESH SUPPORT TO THE BOTTOM OF THE TRENCH. FASTEN THE WIRE REINFORCEMENT, THEN FABRIC ON THE UPSLOPE SIDE OF THE FENCE POST. WIRE OR PLASTIC ZIP TIES SHOULD HAVE MINIMUM 50 POUND TENSILE STRENGTH. 5 C902 NC W STEEL POST WIRE FENCING FILTER FABRIC #57 STONE 30"MIN w E OQ� ��mFFF5� N I Lai,C\,N � 8" MIN 4" MIN 9. WHEN A WIRE MESH SUPPORT FENCE IS USED, SPACE POSTS A MAXIMUM OF 8 FEET APART. SUPPORT POSTS SHOULD BE DRIVEN SECURELY INTO THE GROUND A MINIMUM OF 24 INCHES. 10. EXTRA STRENGTH FILTER FABRIC WITH 6 FEET POST SPACING DOES NOT REQUIRE WIRE MESH SUPPORT FENCE. SECURELY FASTEN THE FILTER FABRIC DIRECTLY TO POSTS. WIRE OR PLASTIC ZIP TIES SHOULD HAVE MINIMUM 50 POUND TENSILE STRENGTH. 11. EXCAVATE A TRENCH APPROXIMATELY 4 INCHES WIDE AND 8 INCHES DEEP ALONG THE PROPOSED LINE OF POSTS AND UPSLOPE FROM THE BARRIER. 12. PLACE 12 INCHES OF THE FABRIC ALONG THE BOTTOM AND SIDE OF THE TRENCH. 13. BACKFILL THE TRENCH WITH SOIL PLACED OVER THE FILTER FABRIC AND COMPACT. THOROUGH COMPACTION OF THE BACKFILL IS CRITICAL TO SILT FENCE PERFORMANCE. 14. DO NOT ATTACH FILTER FABRIC TO EXISTING TREES. MAINTENANCE NOTES: 1. INSPECT SEDIMENT FENCE AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. 2. SHOULD THE FABRIC OF A SEDIMENT FENCE COLLAPSE, TEAR, DECOMPOSE, OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY. 3. REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE FENCE. TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUT. 4. REMOVE ALL FENCING MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED. HARDWARE CLOTH AND GRAVEL INLET_ PROTECTION_ 4' MAX 1A-rl IArF HARnkA/ARF ri (NTH 3 C902 6 C902 TEMPORARY DIVERSION nnR%nAn=n nX ll 2' MIN 1. REMOVE AND PROPERLY DISPOSE OF ALL TREES, BRUSH, STUMPS AND OTHER OBJECTIONABLE MATERIAL. 2. ENSURE THAT THE MINIMUM CONSTRUCTED CROSS SECTION MEETS ALL DESIGN REQUIREMENTS. 3. ENSURE THAT THE TOP OF THE DIKE IS NOT LOWER AT ANY POINT THAN THE DESIGN ELEVATION PLUS THE SPECIFIED SETTLEMENT. 4. PROVIDE SUFFICIENT ROOM AROUND DIVERSION TO PERMIT MACHINE REGARDING AND CLEANOUT. 5. VEGETATE THE RIDGE IMMEDIATELY AFTER CONSTRUCTION, UNLESS IT WILL REMAIN IN PLACE LESS THAN 30 WORKING DAYS. MAINTENANCE NOTES: 1. INSPECT TEMPORARY DIVERSIONS ONCE A WEEK AND AFTER EVERY RAINFALL. IMMEDIATELY REMOVE SEDIMENT FROM THE LOW AREA AND REPAIR THE DIVERSION RIDGE. CAREFULLY CHECK OUTLETS AND MAKE TIMELY REPAIRS AS NEEDED. WHEN THE AREA PROTECTED IS PERMANENTLY STABILIZED, REMOVED THE RIDGE AND THE CHANNEL TO BLEND WITH THE NATURAL GROUND LEVEL AND APPROPRIATELY STABILIZE IT. STONE OUTLET GENERAL NOTES: 1. STRUCTURAL STONE SHALL BE (CLASS B) STONE FOR EROSION CONTROL PURPOSES. 2. SEDIMENT CONTROL STONE SHALL BE #5 OR #57 STONE. STEEL FENCE POST r`"'4 V'LVV LA I FILTERED WATER 21 GENERALNOTES: 1. UNIFORMLY GRADE A SHALLOW DEPRESSION APPROACHING THE INLET. #57 STONE12" �" LA NC DOT #5 OR #57 2. DRIVE 5-FOOT STEEL POSTS 2 INTO THE GROUND SURROUNDING THE INLET. SPACE POSTS EVENLY AROUND THE PERIMETER OF THE INLET, A MAXIMUM OF 4 FEET APART. V-6" MIN. ElrE WASHED STONE 3. SURROUND THE POSTS WITH WIRE MESH HARDWARE CLOTH. SECURE THE WIRE MESH TO THE STEEL POSTS AT THE TOPS, MIDDLE AND BOTTOM. PLACING A 2-FOOT FLAP OF THE WIRE MESH UNDER THE GRAVEL FOR ANCHORING IS FL 3' MAX. RECOMMENDED. 4. PLACE CLEAN GRAVEL (NCDOT #5 OR #57 STONE) ON A 2:1 SLOPE WITH A HEIGHT OF 16 INCHES AROUND THE WIRE, AND2 II I d SMOOTH TO AN EVEN GRADE. SEDIMENT II 5. ONCE THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, REMOVED ACCUMULATED SEDIMENT, AND ESTABLISH CONTROL STONE II _ FINAL GRADING ELEVATIONS. 6. COMPACT THE AREA PROPERLY AND STABILIZED IT WITH GROUND WATER STRUCTURAL STONE II MAINTENANCEis FILTER FABRIC INSPECT INLETS AT LEAST WEEKLY AND AFTER EACH SIGNIFICATION (z INCH OR GREATER) RAINFALL EVENT. CLEAR THE MESH SECTION VIEW SECTION'A-A' WIRE OF ANY DEBRIS OR OTHER OBJECTS TO PROVIDE ADEQUATE FLOW FOR SUBSEQUENT RAINS. TAKE CARE NOT TO DAMAGE OR UNDERCUT THE WIRE MESH DURING SEDIMENT CONTROL. REPLACE STONE AS NEEDED. v z m 100' TO 200' p �' N• } Q 3 Z DM 0 "42 AHEAD 4B'� X X-�S" ¢ Z m0�-I�fn T11 > 2a• 20' L!0C7 LL J co Lti Z Z = c>o�o� NAX B q © q © q LuQzLL - Z=<00 uoo « �� « .i. W F-L 0 r _ =I Z y W� ♦ ♦ WORK AREA ♦ ♦ � - O OH ¢ O co D D z " s W © W g W TWO-- DaWx N i1 H cn 0 i RMFcc smFsr r LL, O Z N SO' TAPER BUFFER BUFFER TMER MA%. 50'-100' SPACE SPADE 100, BE WOAD PREPAEED • AIfAD TO SIOP r ro N20-4 M3 4 MV4`8" 9B" % qB" % INSET FOR 2 LANE ROADWAYS o WITH 2-WAY TURN LANE N D ALL OTHER DEVICES ARE THE SAME AS ABOVE N O m m z O W - 3 0 LL oc N O F-L 0 noso E tc ♦ WORK AREA ♦ sc cEcoSLo E Lu Z y �N fn 'lL m W20-fi ♦ W20-B 4e" X L" H ¢ O = D D 90" % 48" ♦ ♦ ♦ Q J <m(n <c�r k D NB.NA. TRAFFIC Q i Dr- O TAPER BUFFER BUFFER "l-E.R Z DD ZI O00SPACE 6,ACE ¢ D J ¢o m v GENERAL NOTES FOR FLAGGER OPERATIONS GENERAL NOTES FOR PILOT CAR OPERATIONS Z v 1- REFER TO STD. 1101.11 SHEET 4 FOR SIGN SPACING. 1- USE PILOT CARS WHEN DIRECTED BY THE ENGINEER. ¢ >- I= 1 ('� M D 2- INSTALL LANE CLOSURES WITH THE TRAFFIC FLOW, BEGINNING WITH DEVICES ON THE 2- IF ROADWAY WIDTH IS LESS THAN 22 FEET (EDP TO EDP CONES MAY NOT BE REQUIRED UPSTREAM SIDE OF TRAFFIC. ALONG WORK AREA AND AT THE DISCRETION OF THE ENGINEER, CONES MAY BE OMITTED ALONG cc } ¢ r Q 3- REMOVE LANE CLOSURES AGAINST THE TRAFFIC FLOW, BEGINNING WITH DEVICES ON THE THE WORK AREA I� USING A PILOT CAR. _ 3 N Z DOWNSTREAM SIDE OF TRAFFIC. 3- CONES ARE ALWAYS REQUIRED IN THE UPSTREAM AND DOWNSTREAM TAPERS. H O N Z M C 0 4- PLACE CONES THRU THE WORK AREA AT THE MAXIMUM SPACING EQUAL IN FEET TO 2 TIMES 4- MOUNT SIGN G20-4 "PILOT CAR FOLLOW ME" AT A CONSPICUOUS POSITION ON THE REAR OF J a T THE POSTED SPEED LIMIT. THE PILOT VEHICLE. C D FE r0 y 5 EXTEND LAN ELANE CLOSURE. - MEASURED FROM THE BEGINNING E END -OE MILE THESFRLAGGEH THE To TSHEETT2�PING SIGHT DISTANCE IS 5- OF THE MERGELTAPER UU � Q TTHAN STDAC1101.11 fn 6- DO NOT STOP TRAFFIC IN ANY ONE DIRECTION FOR MORE THAN 5 MINUTES AT A TIME. 6 ADVISE RESIDENTSBUSINESSESSS FROM WITHINVEWAYS THEDURLANNG ELCLOSURE ND ABOUT SAFE AGGING ALIMITS T CAR OPERATIONS. J m 7- DRUMS OR SKINNY -DRUMS MAY BE USED IN LIEU OF CONES. REFER TO ROADWAY STANDARD DRAWING 1180.01 FOR SKINNY -DRUM REQUIREMENTS. N 8- USE FLAGGERS TO CONTROL TRAFFIC AT INTERSECTIONS AFFECTED BY THE LANE CLOSURE. LEGEND SUPPLEMENT FLAGGERS LOCATED AT INTERSECTIONS WITH FLAGGER AHEAD SIGNS W20-7a) PLACED APPROXIMATELY 25U FT. IN ADVANCE OF THE FLAGGER. FOR SIGNALIZE FLAGGER I NTERSEGTIONS PLACE SIGNALS IN THE FLASH MODE AND RECOMMEND THE USE OF LAW ENFORCEMENT. ♦ CONE 9- REFER TO 2009 MUTCD, CHAPTER 6, FOR FLAGGER CONTROL, REQUIREMENTS, AND PROCEDURES. IQ PORTABLE SIGN 10- DO NOT EXCEED A 1 MILE LANE CLOSURE LENGTH UNLESS OTHERWISE SHOWN IN THE TMP OR DIRECTION OF TRAFFIC FLOW AS DIRECTED BY THE ENGINEER. IISHEET 1 OF 15 1101 , 02 SHEET 1 OF 15 1101 .02 v CONTINUOUS LINES 10'-30'/SP SKIP LINE 2'-6'/SP MINI -SKIP LINE z m o� o} UNLESS OTHERWISED SHOWN, USE 10'-30'/SP SKIPS FOR SKIP LANE LINES AND SKIP CENTER LINES. UNLESS OTHERWISEO 6HOWN, U6E 2'-6'/SP MINI-6KIPS FOR LANE LINE EXTENSIONS THROUGH INTERSECTIONS, EDGE LINE r ¢ M z ."0 0 O EXTENSIONS THROUGH INTERSECTIONS AND MINI -SKIPS ¢ ¢ H- 3 DL om EDGE LINE 10' 30' USED FOR BICYCLE LANE LINES. H 2 U Lm-LZ = D YELLOW OR WHITE 4"/6„ LL J �LtiZ C, O �-) fn = =oDDT�rL o a"/s" z' 6' HUQLLo= O zHop�T LANE LINE YELLOW OR WHITE � o o a"1s" ¢ LO-L cnLLo_j C7 O o ~ 4"/6" YELLOW OR WHITE ¢ O LH ¢ ' D D WHITE O fn z 3'-3'/SP MINI -SKIP LINE 3'-9'/SP MINI -SKIP LINE CD r 0- O LLL Z CENTER LINE UNLESS OTHERWISED SHOWN, USE 3'-3'/SP MINI -SKIPS FOR THE WHITE EDGE LINE ENTENSIONS AT ROUNDABOUTS. UNLESS OTHERWISED SHOWN, USE 3'-9'/SP MINI -SKIPS FOR MINI -SKIP LANE LINES AND LINE EXTENSIONS THROUGH TAPERS. YELLOW GORE LINE 3 9 O O 4„/6rr 8.r/12" 12' WHITE WHITE WHITE m 0 r r DIAGONAL LINE A 12" 45 MPH OR HIGHER o LL U) Z > O 6" LESS THAN 45 MPH Z (3 W m C = YELLOW OR WHITE H Z 0 � 3 < LL cn �mn ooCo m Z zo CROSSWALK LINE o z D 8" TRANSVERSE Z 33 O WHITE 24" LONGITUDINAL 0 O o D wa o ¢z `Z co E ~ cn Z H RxR LINE W Lu m o Z N N cf) z J a T 0 WHITE � J Z W STOP OR TRANSVERSE BA I GENERAL NOTES: 1- USE "' LANE, EDGE, AND CENTER LINES ON ALL FULL CONTROL OF ACCESS FACILITIES AND OTHER ROUTES 24" AS DIRECTED BY THE ENGINEER. WHITE 2- LANE LINES INDICATED AS "WIDE" ON THE ROADWAY STANDARD DRAWINGS SHALL BE AT LEAST TWICE THE WIDTH OF THE NORMAL LINE. 3- GORE LINES SHALL BE TWICE THE WIDTH OF THE NORMAL LINE. SHEET 1 OF 2 SHEET 1 OF 2 1205.01 1205.01 v STRAIGHT ARROW1 RIGHT OR LEFT COMBINATION STRAIGHT AND COMBINATION LEFT AND z o TURN ARROW LEFT OR RIGHT TURN ARROW RIGHT TURN ARROW �fn 70 CD ZO ro L--L �7 (n fm-L Z = D 20" 6'-4" 36" 6rr 201' 36r SAME DIMENSIONS APPLY AS FOR THE LEFTIRIOHT TURN ARROW ¢ C, 3 Z= F-I C7 U LL JO = Z =oDDL�TL B" Lu<LLo= o OC C3 �m>om m m oo¢ COMBINATION LEFT AND STRAIGHT �-1D 1q" AND RIGHT TURN ARROW Z M� _ < H i N O 14" T v V N 0] N R=40" _ v N d L'-L r ED C3 Z N 4" a N 32 m R=28" a 4r' SAME DIMENSIONS APPLY AS FOR THE COMBINATION STRAIGHT AND LEFT/RIGHT TURN ARROW r 12" R=40" 32.r 12rr 12rr R=28rr 6r_4rr MERGE ARROW RAMP ARROW � z r m o FOR WRONG -WAY MOVEMENTS ON FREEWAY AND EXPRESSWAY RAMPS U)p, LL LL1 WO C S o -ry, rypOl' PAVEMENTRED MARKER oz Z N � 3 cn o 8, 2'-6"_ N 3 N LLJ 2 D MD E■ O cc OZ Z a co 8"----------------``'.�� -- fL OF RAMP Q OD a 2v 2r 6rr i--�- O o m v _ s ¢ 3 ¢ Z Z A Z 2�r. TYP. UJ ¢ m 11-I >* 16'-8" 7'-1" < O IS fn fnZz =�J Q m GENERAL NOTES: 1- USE THE COLOR WHITE FOR ALL PAVEMENT MARKING SYMBOLS. N v r1T (1)0 100 �, RP AROW ATMEXITRRAMP J a ME W 2- DO NOT LOCATE PAVEMENT MARKING SYMBOLS AS TO ENCROACH INTO INTERSECTION AREAS. 3- DO NOT PLACE PAVEMENT MARKING SYMBOLS ACROSS TRANSVERSE EXPANSION JOINTS ON PORTLAND CEMENT CONCRETE PAVEMENTS, UNLESS APPROVED BY THE ENGINEER. 4- CONFORM ALL SYMBOLS TO THE FHWA "STANDARD ALPHABETS FOR HIGHWAY SIGNS AND PAVEMENT MARKINGS", (REFER TO SHEETS 5 THRU 8). SYMBOL DIMENSIONS CAN VARY AMONG MANUFACTURERS, THEREFORE SLIGHT VARIANCES ARE ACCEPTABLE, HOWEVER, ALL RAMP ARROW AT EXIT RAMP HEET 1 OF 7p SHEET 1 OF 8 1205.08 SYMBOLS ARE REQUIRED TO BE APPROVED BY THE DEPARTMENT. 1p0Y 1205. OR I� 1), RAAY II FRONT VIEW II II II u u nLL T rrNLnr Lu w B EC Lu Lu a_ O ENGINEERING I PLANNING I ENVIRONMENTAL Q 1520 MEADOWUIEW DRIVE Q WILKESBORO, NC 28697 0 336.844.4088 http://brec.biz LL\J L1J , H CAP? .0 \\ Lu 0Fess 9 LU A = m CND .�`. rrr)(I)k%\��\ W 02/04/2020 Z Q J L u OPqT ••.� = Q NCBELS#C-3448? _ U) Z H 2 •. Q.: O 0 W ti Z z o W t7 zN w o wo Z W mi DETAILS PREPARED FOR: TERAMORE DE' PO BOX 6560 THOMASVILLE, JELOPMENT GA 31758 iDATE: REVISIONS: SHEET SIZE: 24"x36" DATE: 01/15/2020 PROJECT NUMBER: 3160622019 DRAWN BY: J.EDWARDS APPROVED BY: J.CHURCH SCALE: NTS (H) (N) SHEET: C902 © COPYRIGHT 2020 BY BREC, P.A., ALL RIGHTS RESERVED. THIS PLAN MAY NOT BE RE -USED, SOLD, LOANED, OR GIVEN TO OTHERS. REPRODUCTION OR PHOTOCOPYING OF THIS PLAN WITHOUT THE WRITTEN CONSENT OF BREC, P.A. IS PROHIBITED AND IS A VIOLATION OF FEDERAL COPYRIGHT LAWS, PUNISHABLE BY FINES UP TO $100,000 PER OFFENSE.