Loading...
HomeMy WebLinkAboutSW1210602_Plansheet - Misc. Detail_20210630DocuSign Envelope ID: 61796BC1 -4762-4278-AF1 1-747CBB7384D7 MIN. COVER TO RIGID PAVEMENT, H if 6" __T_ SPRINGLINE k 1�� 7�� - "yati'Xi'.�„tr.�'u{j:;. y4.:,Sn^: ,t.yG;�ti.�fyYy�ir•�iur. :yi `.4. "r': ".•t. :Y<^.`.?:ti .` k: +" atC:4'�a ,j:7.M.:^Lxr`L 4" FOR 12-24 PIPE 6" FOR 30"-60" PIPE MIN. TRENCH WIDTH (SEE TABLE) NOTES: FINAL BACKFILL MIN. COVER TO FLEXIBLE PAVEMENT, H INITIAL BACKFILL HAUNCH BEDDING SUITABLE FOUNDATION 1. ALL PIPE SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH ASTM D2321, "STANDARD PRACTICE FOR UNDERGROUND INSTALLATION OF THERMOPLASTIC PIPE FOR SEWERS AND OTHER GRAVITY FLOW APPLICATIONS", LATEST ADDITION 2. MEASURES SHOULD BE TAKEN TO PREVENT MIGRATION OF NATIVE FINES INTO BACKFILL MATERIAL, WHEN REQUIRED. 3. FOUNDATION: WHERE THE TRENCH BOTTOM IS UNSTABLE, THE CONTRACTOR SHALL EXCAVATE TO A DEPTH REQUIRED BY THE ENGINEER AND REPLACE WITH SUITABLE MATERIAL AS SPECIFIED BY THE ENGINEER. AS AN ALTERNATIVE AND AT THE DISCRETION OF THE DESIGN ENGINEER, THE TRENCH BOTTOM MAY BE STABILIZED USING A GEOTEXTILE MATERIAL. 4. BEDDING: SUITABLE MATERIAL SHALL BE CLASS I, II OR III. THE CONTRACTOR SHALL PROVIDE DOCUMENTATION FOR MATERIAL SPECIFICATION TO ENGINEER. UNLESS OTHERWISE NOTED BY THE ENGINEER, MINIMUM BEDDING THICKNESS SHALL BE 4" (100mm) FOR 4"-24" (100mm-600mm); 6" (150mm) FOR 30"-60" (750mm-900mm). 5. INITIAL BACKFILL: SUITABLE MATERIAL SHALL BE CLASS I, II OR III IN THE PIPE ZONE EXTENDING NOT LESS THAN 6" ABOVE CROWN OF PIPE. THE CONTRACTOR SHALL PROVIDE DOCUMENTATION FOR MATERIAL SPECIFICATION TO ENGINEER. MATERIAL SHALL BE INSTALLED AS REQUIRED IN ASTM D2321, LATEST EDITION. 6. MINIMUM COVER: MINIMUM COVER, H, IN NON -TRAFFIC APPLICATIONS (GRASS OR LANDSCAPE AREAS) IS 12" FROM THE TOP OF PIPE TO GROUND SURFACE. ADDITIONAL COVER MAY BE REQUIRED TO PREVENT FLOATATION. FOR TRAFFIC APPLICATIONS, MINIMUM COVER, H, IS 12" UP TO 48" DIAMETER PIPE AND 24" OF COVER FOR 54"-60" DIAMETER PIPE, MEASURED FROM TOP OF PIPE TO BOTTOM OF FLEXIBLE PAVEMENT OR TO TOP OF RIGID PAVEMENT. 18" X 18" X 4" CONCRETE PAD POURED AROUND ALL CLEAN OUTS. UNLESS STORM DRAINAGE SCH 40 UNLESS OTHERWISE NOTE[ ON PLANS 0 r-i Q 00 7i N N O Ln N 3 a� a 0 N O M U i i U v c V7 i U .o L Q w Ln D LL RECOMMENDED MINIMUM TRENCH WIDTHS PIPE DIAM. MIN. TRENCH WIDTH 4" 21" 6" 23" 8" 26„ 10" 28" 12" 30" 15" 34" 18" 39" 24" 48" 30" 56" 36" 64" 42" 72" 48" 80" 54" 88" 60" 96" MINIMUM RECOMMENDED COVER BASED ON VEHICLE LOADING CONDITIONS SURFACE LIVE LOADING CONDITION PIPE DIAM. H-25 HEAVY CONSTRUCTION (75T AXLE LOAD) 12" - 48" 12" 48" 54" - 60" 24" 60" VEHICLES IN EXCESS OF 75T MAY REQUIRE ADDITIONAL COVER MINIMUM RECOMMENDED COVER BASED ON RAILWAY LOADING CONDITIONS PIPE DIAM. COOPER E-80** UP TO 24" 24" 30"-36" 36" 42"-60" j 48" ** COVER IS MEASURED FROM TOP OF PIPE TO BOTTOM OF RAILWAY TIE. *** E-80 COVER REQUIREMENTS, ARE ONLY APPLICABLE TO ASTM F 2306 PIPE. TYPICAL HDPE STORM DRAINAGE TRENCH DETAIL # 107 VALVE BOX & LID PVC COMBINATION ROOF LEADER CLEANOUT DETAIL N.T.S. NOT TO SCALE FINISHED GRADE — MANHOLE RING & COVER CURB TRANSITION TYPICAL ALL CURB X INLET LOCATIONS BOTH SIDES OF INLET — CATCH BASIN 6" I� CULVERT 12" 5, 5 BACK OF CURB 000000 2� 000000 PIER (TYP.) INSTALL MANHOLE RING & F CE OF CURB LIP OF GUTTER COVER IN TOP OF OTCB STANDARD CURB & GUTTER CONCRETE COVER TOP ELEV. AS NOTED ON PLANS CURB TRANSITION AT CURB INLET PIER NOT TO SCALE FLOW FLOW 6 OPENING FRAME, GRATE &HOOD BY TINDALL OR APPROVED EQUAL FINISH GRADE ASPHALT III- I II I I — VARIES REINFORCED ;: ,.;:,:_;.::<,.;:.,:..,,,,. ; — 8„ PROPOSED STEPS PRECAST BOX WITH I IIIII i �- 12" C—C MIN. KNOCKOUT PANELS I III— — - 16" C—C MAX.— (TYP.) CULVERT TOP GRATE ELEV. AS 1= NOTED INV. ELEV. 0 0000000 000000000 = 6" MIN VARIES AS REQ'D PRECAST CONCRETE BOX AS NOTED = WITH KNOCKOUT PANELS ON PLANS 1 = 8" PRECAST CONC. BASE AS MANE. BY TINDALL OR APPROVED EQUAL WELL COMPACTED #67 STONE, #57 STONE SUBGRADE COMPACTED COMPACTED OPEN THROAT CATCH BASIN 6„ WITH MANHOLE RING & COVER —00— 6" MIN 0000000000000000— NOT TO SCALE — o0 0 0 0 0 0 0 0 0 0 0 = COMPACTED SUBGRADE �4,000 PSI CONCRETE 6" 4" OF CABC MINIMUM UNDER FLUME EXTENDED 6" PAST CURB CONCRETE FLUME FOR 8I0—RETENTION CELLS SECTION N.T.S. EXTEND FLUME TO BOTTOM OF BIO—RETENTION CELL (12" LEVEL) I CURB & GUTTER \-4,000 PSI CONCRETE VFW-,-" 4" OF CABC MINIMUM UNDER FLUME OUTLET PROTECTION AS NOTED ON PLANS CONCRETE FLUME FOR BIO—RETENTION CELLS DETAIL N.T.S. 6" HIGH CURB CONCRETE END TREATMENT NOT TO SCALE CURB INLET NOT TO SCALE WGLA ENGINEERING, PLLC 724 5th AVENUE WEST HENDERSONVILLE, NC 28739 (828) 687-7177 WGLA.COM INC LICENSE P-1342 SunCap PROPERTY GROUP" Suncap Warehouse Town of Mills River Henderson County North Carolina OC�2 °�go — o 07CO3 K2 y1D... o° — o _ o o°,ciN°° ,�� /A M R65Q�4/2021 REVISIONS DATE DESCRIP11ON V Know what's below. Call before you dig. PROJECT NUMBER: 20176 DATE: 4/21 DRAWN BY: KHC CHECKED BY: WRB Storm Drainage Details C-306 SCALE: As -Noted -On -Sheet