HomeMy WebLinkAboutSW1210602_Plansheet - SCM Detail_20210630 (2)DocuSign Envelope ID: 61796BC1 -4762-4278-AF1 1-747CBB7384D7
0
r-i
Q
N
00
N
0
N
N
3
W
0
0
N
0
M
U
U
c
U
'o
L
Q
w
Ln
D
LL
PROPOSED
EMERGENCY
SPILLWAY
PROPERTY ♦ /
BOUNDARY
10' BERM
,c
1413\F LF PROPOSED 4" SLOTTED PVC/SCH 40
26 LF 0-- t w \ UNDERDRAIN (TYP.) (3,105 LF TOTAL)
31 LF 10 LF14- \ 22 LF \
10„ LF "U
w
42 LF w 10 LF 32\&LF
47 // W 10 LF �`
LF � _ _ � _ _ _ 43 LF +2120� .1�
w w
PROPOSED 4" PVC/SCH 40 52 LF / --10 LF w_ 58 LF _ w �� 2
w .��
10 LF w
- - -
CLEANOUT (TYP.) (40 TOTAL) /20
I
PROPOSED I
FOREBAY #5
PROPOSED
CI #18
58 LF 10 LF I w " 127 LF w w I- /2Q PR(
.__,___,I__,�___,_Y__,�_,______,_.0 w
/ 63 LF " 10 LF w " w 148 LF ` w w w ��\ (TC
/ _ � _ _,_� - - - -� - - - - w w TO
68 LF 10 LF i w 16-I LF " VIw\_ `
�.w_ _ _ _ _- _ 4
w w 73 LF w „10 LF - ° w 175 LF _ _ VI
_ W_ _ x \
/ - - - - - - - w -w- - - w c - -� w \ w \
w 10 LF
_� 79,,-LF _ _ _ �,_!_ _P_,_ _ w _ �84 LF w w V-- � - -- - - � - - w\
/ w 84 LF w 10 LF !� _ w_ 191 LF x
w ¢ 90 LF w 10 LF `° w w w �,� �`-� 195 LF ,_ � �_� w w �!
/wV,_ 95 LF w10 LF w w 163 LF w w w \
/ V. w w 92 LF 10 LF i w " 66 LF w w w 37 LF - i` 10-LF 32 LF
82 LF _ _ 10 LF w 61 LF_ _ 32 LF w 10 LF _~� 32 ` l I I
0--w - - - � _ w w _ _ �, _ _ U.. w� - - V -6- - - � w
w w w w w w w w
w �� 32 LF
2120
PROPOSED
FOREBAY #6
PROPOSED PROPOSED -
CI #19 CI #20
PROPOSED STORMWATER
BIO-RETENTION CELL "B"
SCALE 1 " = 40'
•-
A
•'
LAYER •
SOIL MEDIA
•
0
I I I I I L,I • I_�
MEDIA MIX
THE MEDIA SHOULD BE COMPOSED OF A
HOMOGENOUS MIX OF THE FOLLOWING:
a. 75-85% MEDIUM TO COURSE WASHED
SAND
b. 8-10% FINES (SILT AND CLAY); AND
c. 5-10% ORGANIC MATTER (SUCH AS PINE
BARK FINES)
MINIMUM MEDIA DEPTH
ALL CELLS WITH TREES AND SHRUBS:
36 INCHES
CELLS WITHOUT TREES AND SHRUBS:
WITH NO IWS: 24 INCHES
WITH IWS: 30 INCHES
MEDIA P-INDEX
LESS THAN 30 IN NSW WATERS
LESS THAN 50 ELSEWHERE
MEDIA MAINTENANCE
MAINTAIN MEDIA SUCH THAT INFILTRATION
RATE IS AT LEAST 1 IN/HR
CONSTRUCTION SEQUENCE:
1.) DO NOT ALLOW FLOW INTO 810-RETENTION CELL UNTIL SITE
IS STABILIZED. (PAVED / GRASS)
2.) CLEAN OUT CELL IF USED AS A SEDIMENT BASIN DURING
CONSTRUCTION.
3.) INSTALL 8" LAYER OF STONE, UNDERDRAINS.
4.) INSTALL FILTER FABRIC, 4" WASHED SAND AND SOIL MEDIA.
5.) INSTALL 4- LAYER OF TRIPLE SHREDDED HARDWOOD MULCH
IN ENTIRE CELL.
PROPOSED
OUTLET #3�
tffffftffffffftfttf
PROPOSED LEVEL
SPREADER #2
F - - - --
PROPOSED STORM DRAIN
DISCHARGE LINE
10yr STORM DETENTION PONDING
ELEV. = "G"
-9" OPENING
(INSTALL TRASH RACK/SCREEN
ON OPENINGS) ELEV. = "A"
TOP OF OCS #11 (OVERFLOW
STRUCTURE) W/ MANHOLE 10'
RING AND LID PRECAST
FLUSH INTO TOP I�
AS NOTED
ON FOREBAY DETAIL
9" RIP RAP (SEE RIP RAP"XI
ENERGY & VELOCITY DISSIPATER
SECTION FOR ADDITIONAL DETAILS)
BIO-RETENTION CELL FOREBAY WEIR SECTION
N.T.S.
BERM
TOP ELEV. = "F"
9" RIP RAP (SEE
EMERGENCY SPILLWAY ENERGY & VELOCITY DISSIPATER
ELEV. = "I" SECTION FOR ADDITIONAL DETAILS)
810-RETENTION CELL EMERGENCY SPILLWAY SECTION
N.T.S.
................
;.................. I JlI ICI I•
INV. ELEV.= "E" PROPOSED 30" HDPE
(WTJ) STORM DRAIN TO OUTLET #3
LINE ® 0.73%
(LEVEL SPREADERC
77 7 I 7 74-IImo- 7 I-7rl I7 -I I•I iTi •i 1T�i i• i,
II IIIIIIIIII IIII
INVERT OF OTCB it ITrI l III III III III III III III III
- (INTERIOR OF BOX)
ELEV. = "H"
it 24" 1 on
-' "-- TO 12" BELOW
)ISCHARGE
'*-- 9" d50 STONE (RIP RAP)
RIP RAP ENERGY & VELOCITY
DISSIPATER SECTION
NOT TO SCALE
1310-RETENTION CELL TABLE
CELL #
ELEV. "A"
ELEV. "B"
ELEV. "C"
ELEV. "D"
ELEV. "E"
ELEV. "F"
ELEV. "G"
ELEV. "H"
ELEV. "I"
# OF
CLEANOUTS
Wq VOLUME
REQUIRED
Wq VOLUME
PROVIDED
B
2118.00
2118.00
2117.00
2116.00
2115.16
2120.00
2118.32
2110.50
2119.00
40
27,409 CIF
39,330 CF
/ / / /
12" HIGH RIP RAP ENERGY &
VELOCITY W/ FILTER STONE -k
PROPOSED 9" d50 STONE
RIP RAP EXTENDED TO
ELEV. 2118' I
PROPOSED OUTLET/#9
1
PROPOSED
CI #18
PROPOSED FOREBAY ##5
SCALE 1 " = 20'
12" HIGH RIP RAP ENERGY &
VELOCITY W/ FILTER STONE -
V_
V_
�-'-'♦ of
51'
PROPOSED 9" d50 STONE
RIP RAP EXTENDED TO
ELEV. 2118'
PROPOSED OUTLET #10
CI #19
I
PROPOSED FOREBAY ##6
SCALE 1 " = 20'
NOTES:
1.) OVERFLOW STRUCTURE SHALL HAVE STANDARD STEPS, 16" ON CENTER PRECAST INTO BOX DIRECTLY BELOW MANHOLE ACCESS AND
NOT LOCATED ON SIDE OF BOX THAT HAS AN ORIFICE OR THE OUTLET PIPE.
2.) IN -SITU SOIL MUST NOT BE COMPACTED BY EQUIPMENT.
3.) CELL BOTTOM SHOULD BE SCARIFIED PRIOR TO CELL MATERIAL INSTALLATION TO PROMOTE INFILTRATION.
4.) THE MAXIMUM SIDE SLOPES FOR THE INSIDE OF THE 810-RETENTION CELL SHALL BE 3:1. (ELEVATION "F" TO ELEVATION "C")
5.) BIO-RETECTION CELL SHALL BE MULCHED AND PLANTED W/ TREES AND SHRUBS (SEE LANDSCAPING PLAN FOR PLANTINGS).
6.) HDPE PIPING LEAVING OCS SHALL HAVE WATER TIGHT JOINTS.
7.) OCS #11 SHALL BE A MIN. OF 5'x5' PRECAST CONCRETE BOX. KNOCK OUT PANELS (WAFFER BOX) SHALL NOT BE ACCEPTABLE. A
MANHOLE RING AND LID SHALL BE PRECAST FLUSH INTO TOP OF LID.
8.) SOIL MEDIA SHALL EXTEND BENEATH THE ENERGY DISSIPATING DEVICE (FOREBAY) INSIDE BIO-CELL.
9.) TRASH RACK SHALL EXTEND FROM INVERT OF OCS OPENING WEIR TO INVERT OF TOP. TRASH RACK SHALL NOT HAVE ANY
OPENINGS GREATER THAN 54" IN ANY DIRECTION AND SHALL BE MADE OUT OF A NON -CORROSIVE METAL MATERIAL W/A MIN I"•
(REBAR IS NOT ACCEPTABLE).
10.) THE BIO-RETENTION CELL MEDIA SHALL BE MAINTAINED IN A MANNER THAT RESULTS IN A DRAWDOWN OF AT LEAST ONE INCH PER
HOUR AT THE PLANTING SURFACE.
11.) IMPERMEABLE LINER SHALL BE EXTENDED TO ELEVATION "C- IN THE BIO-RETENTION CELLS.
•
PATH
V CONCRETE• • • 'NVERT ELEV. OF CONC.
CHANNEL = • : • •
STONE
12" WIDE J
SECTION "A"VIEW CURB FOOTER
NOT TO SCALE
FLOW
_ PATH
I1= 8'
12„
12" LAYER OF 12" STONE
INV. OF TOP OF STONE _
114' j
IN 21INVERT00F CHANNEL
200 Ib TENSILE
STRENGTH FILTER FABRIC
SECTION "B" VIEW 12" WIDE
NOT TO SCALE CURB FOOTER
12" LAYER OF 9" STONE TOP OF CURB
(3 FT WIDE) ELEV. 2104.0'
-i i I-111--
18 a..
- 3 FT. WIDE STRIP 12
OF FILTER FABRIC
CONCRETE DETAIL
NCDOT CURB NOT TO SCALE
STD. 846.01
8" X 18" W/ FOOTER
12" LAYER OF
9" STONE
(3 FT WIDE)
- 3 FT. WIDE STRIP
OF FILTER FABRIC
NCDOT CURB
STD. 846.01
8- X 18" W/ FOOTER
NOTES:
1.) BOTTOM WIDTH SHALL BE 24" W/ 3:1 SIDE SLOPES.
2.) 122 LF LEVEL SPREADER LENGTH.
3.) EXTEND CONCRETE CURB LEVEL SPREADER AROUND END FOR
10' (LENGTH NOT INCLUDED IN NOTE #2).
4.) EXTEND CONCRETE CURB UP AND AROUND OUTLET #3 AS TO
DIRECT FLOW INTO LEVEL SPREADER AND OVER CONCRETE CURB
PRIOR TO BYPASSING AROUND CONNECTION TO FES.
NCDOT CURB
STD. 846.01
8- X 18- W/ FOOTER
PROPOSED LEVEL SPREADER #3 DETAIL
NOT TO SCALE
PIPE
END SECTION
WGLA ENGINEERING, PLLC
724 5th AVENUE WEST
HENDERSONVILLE, NC 28739
(828) 687-7177
WGLA.COM
NC LICENSE P-1342
Suncap
Warehouse
Town of Mills River
Henderson County
North Carolina
CAR
,00 o0oo,
�� o I
ti
°a -
- - 07CO3,K21 q8 11D... oo -
o o/
oN oo
o,clN.000 <
AM R 5/2021
REVISIONS
DATE
DESCRIP11ON
•
V
Know what's below.
Call before you dig.
PROJECT NUMBER: 20176
DATE: 4/21
DRAWN BY: KHC
CHECKED BY: WRB
Bio-Retention
Cell "B"
C-303
SCALE: As -Noted -On -Sheet