Loading...
HomeMy WebLinkAboutSW8960920_HISTORICAL FILE_19961112STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. I SW DOC TYPE El CURRENT PERMIT ❑ APPROVED PLANS HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE YYYYMMDD EXISTING DITCH 1 1+ II � to 36.0 RCP II ' THE CAPE I, BOULEVARD �J:crs.,!'"�:2'.•7 :.7.}.F_, OFFSITE DRAINAGE l 1 I -I,-.4_t•_�,f` ?,. rlll II,II I I �r I r r I I 1 I I r.,l�l.".' i' b!' •.: ' I l' i 1 h I' I TO POND *2 I I l t l 13tlj ,f,..?4D I III 111 Iltl , 3.96 AC. , rr . ,' ♦ r , 1 r.. i I I11 I il+ �I I t /Jrr rlrl�„ POND Yi3 l 1 f l f+ f36f l—!r 1/1/l,'r'1 r r , 1 , .� I r r r I� ��••+.lr •' J� �r1 / , /I 1 / I it t1. ,,,,/i////,' r ' r ,•'� f r I I ����' j' 30'RCP -�� / / / 11 I / t t t 1=38��// jr r rlr ± 14 t28.1'r POND 41112 •� , / ? /. 1 / ` ` j / f i 1 1. / I CART PATH I ' 21 P6 ♦, 1 r r r i RISER 1 r 1 27 I� / — J r r 1 !r �1 1v GREEN / GREEN iF15 DRAINAGE / 20 r 24"RCP 7 r I TO POND aft �' I r r ' ' , , rl�� CART PATH? 3.79 AC.17, POND ic!TEE TELFAIR / / / il, // , ,+ v16 it'll / r '11 / + 1'r"tV6.2 SUMMIT r / //�//1ji\fl�,• //' I// fl1 ` 22.2 22 r r ,� ,' / ','' '30 � • '' � I i L1NKSIDER ` 1 ' / // ' 1 1 '+ !r/ ' ' / / r Z6, / / APOROVED /26,/ / /I or/ / NORTH CAROLINA; NVIRON'>t ENTAL _.` . ' DiVE5iC3N OF Ee•iVl`"rvldmtly (ALNIANA[aEWt=M' �.•'•. <.• / r '.. '� r f. e1 Ifllrlf221 I' rs ! / �I' / I SZCarn1Y3i0f �£f11�IC'I10i7 AIoZO r r l I f{ i 37. Tf 1! r �rf %l�• 1 r 1 1 ! � Ir 1,'ill 1 r11,f1'f +rrl ! Ifill it 11 I Q Y �f'� ! R (u} 33� fti f28rI I l YI12 ST" 41 tii•4 ' 1 { i ee OCT 2 21996 TELFAIR SUMMIT PROJ D M ZD STORMWAT R DETENTION OFF —SITE DRAINAGE z POVVDS # 18 2 SCALE: 1 200' r Exrsn,vc Dlrcx II - - + re I I 3s' o RCP / It _ It .: It rIL ' L + THE CAPE t BOULEVARD 1 1 I 11,Ni`!+r fir•. h,`"F:a ,'�, 1�11','+:I OFFSITE36"0 RCP "lII DRAINAGE i if l i I TO POND *2 I I 11I 1 la�VOl, f fl+ 11'tt�t++ 3.93 AC. � 1,1 t1rf,'I �Lr1 f,1�I1f 111 f , r , ' ���. f , 1 , �• r + l l I l l l f � `_�/, 1� +1,I l e a POND V3 1 !l 1 + + ' / ,' S' � I 1 I I I ►►= ••' �• -�f1 /' 30"RCP • / /, I r f \ 38_do .'/r'�'i'i''. + ' 1 ■ 1, , / , ' , \ , POND 4; 2 p v / ! ' ! ' 2� l'6 " ! !' 'I ' + RISER CART PATH ! 1' 22 GREEN / GREEN / r OFFSITE I' , , / I r 28 '' ' j---. rrr�l,�r�rrrr+rr�r ' 7f !'.S, / I / ;IT DRAINAGE ! ��,rrrr^ + // 24" RCP TO POND iR! ' 20 ,' + r ' /' ,' ,h'�j CART PAIN jir r f POND JV I TELFAIRI�6 SUMMIT _ i// ' 2Z.Z 22 I + e /',' '30, • \ ' �, + ,'+1 t ,' LINKSIDER /,' /,' /!! ' '! , ''' /'/r"'APPROVED ////',30" .1, i is R,I'rl CAROL S"�F r''''rRCNMENTAL 22, /, '! , % - '/. '.' • ',' /MANAGEthr- !sMSi Ca: QE ENWI' t ,�":.":U')ON / +21.0 /' / . �'� /�,' '� ; �26PWOEIJT,4L hIANAGEMENT ;';; 2; pats �ZU �s9� va4Za r ! 37.7>• IIt!','r!!1•rlr�r r1 E C E I V E ,Ill�ftl �I11 l l2By,\ 1 I' ll lfl I t ' , 1 k ,% ,\,, { 1!l l,' yl 1 , !z OCT 2 21996 PAW 07q& 1 if , I ♦ — f 1 / TELFAIR SUMMIT STORMWATER DETENTION OFF —SITE DRAINAGE TO PONDS * I & 2 SCALE: 1 200' TELFAIR SUMMIT STORMWATER DETENTION POND CALCULATIONS RUNOFF CALCULATIONS - TELFAIR SUMMIT SITE Impervious Surfaces: 40 units @ 2,100 SF each (includes option of covering decks and front steps) = 1.93 AC. Street and driveway paving (excludes section of Valley Brook Road from Telfair's Creek to Building 20 which has no curb & gutter) = 1.41 AC. Impervious Surfaces (Onsite) = 3.34 AC - Pervious Surfaces (Onsite) = 3.06 AC. RUNOFF CALCULATIONS - OFF PROJECT SITE Impervious Surfaces: 2 Buildings (7 -36' x 36' Blocks) in Linksider = 0.21 AC. Driveways (3 single @ 440 SF; 5 double @ 880 SF) - 0.13 AC. Street (3501 x 26'W) = 0.21 AC. Cart Paths (1,430 LF x 7'W) = 0.23 AC. Impervious Surfaces (Oftsite) = 0.78 AC. Pervious Surfaces = 6.95AC. STUB POND SIZE CALCULATIONS: 4.12 AC. x 0.083' rainfall = 14,986 CF Q E C E I V E x 10.01 A . ' rainfall x .2 _ 2 F � C • !i3 7 _ 3i C OCT 2 21996 Total Runoff Volume - 22,224 CF PROD #5:,L}` °C(00 166,680 Gallons Ponds #1 and #2 are interconnected to serve as a single detention pond (Ponds are existing, side slopes are stabilized at approximately 2:1). S� - Pond #1 area @ Storage Pool Elev. of 16.8' _ 29,795 SF .� Pond #2 area @ Storage Pool Elev. of 16.8' = 19,994 SF '�" LAgOI Total Storage Pool area of Elev. 16.8` = 49,789 SF �LAL ' S. SE/TSPOND - 1 , IofzL196 Pond #1 area @ Permanent Pool Elev. 16.3' = 28,075 SF Pond #2 area @ Permanent Pool Elev. 16.3' = 18,750 SF Total Permanent Pool Area at Elev. 16.3' = 46,825 SF Average Pond Surface Area = 48,307 SF 22,224 CIF _ 48,307 CF = 0.46' Storage Depth Required Percent Impervious Area = 4.12 AC. _ 14.13 AC. = 29.2% Pond Depth = 6.0' SA/DA % Required for 90% Solids Removal (See Chart) '= 1.6% 1.6% x 14.13 AC. = 0.23 AC. Require Pond Area Permanent Pool Area = 1.07 AC. Actual Pond Storage Volume - 0.5' Depth x 48,307 SF Average Area W 24,154 CIF ORIFICE CALCULATIONS: Use 2 1/2" 0 orifice for dewatering outlet Calculate average discharge rate and time to lower orifice head from 0.5' to 0.4': 0.1' pond height x 48,307 Average Pond Area x 7.5 Gal/Ft3 = 36,230 Gallons Storage Average head on orifice from 0.5' to 0.4' = 0.45' Average discharge rate @ 0.45' head: Q(GPM) = (449)c A 2gh Q(GPM) = Volume discharged in gallons per minute c = discharge coefficient = 0.6 A = orifice area in square feet G = gravity = 32.2 h = head above center of gravity Q(GPM) = (449)(.6)(0.0341) {2)(32.2)(0.45) Q = 49.5 GPM Time required to lower pond 0.1' @ 0.45' average head: T = 36,230 Gal. _ 49.5 GPM = 731 minutes 49.5 GPM vs 731 minutes plotted on curve (see discharge curve). Discharge rate and time to lower head from 0.4' to 0.3': Q=43.6GPM T = 36,230 Gal. _ 43.6 GPM = 831 minutes 43.6 GPM vs 1,562 minutes plotted on curve. SEITSPOND - 2 Discharge rate and time to lower head from 0.3' to 0.2': Q=36.9GPM T 36,230 Gal. _ 36.9 GPM = 982 minutes 36.9 GPM vs 2,544 minutes plotted on curve. Discharge rate and time to lower head from 0.2' to 0.1': Q=28.6GPM T 36,230 Gal. _ 28.6 GPM = 1,267 minutes 28.6 GPM vs 3,811 minutes plotted on curve. Discharge rate and time to lower head from 0.1' to 0.00': Q = 16.5 GPM T = 36,230 Gal. _ 16.5 GPM = 2,196 minutes 16.5 GPM vs 6,007 minutes plotted on curve. The outlet structure will discharge the total calculated runoff volume of 166,680 gallons in approximately 2.9 days (see Orifice Discharge Curve). r �5SIO�ti1q"= SEAL ; 898� •t (D r2 Z 9(i SEITSPOND - 3 so TE L F/M 5 JIB M I 29'2"Of ORIFICE DISCHARCF 44.5GPM,731-MIN sroRMYYArL�R DFrENripN - q3.6 GPMl�5 -0 MIN 3 6, 9 G PM1354AL M►N z8, bGPM�3Bl1 MIN 2,S'' � oRiFtc� t7rscl-��r�GEs 1(.6)6,90 GALS, CALCULArED 30 RUNOFF IN 2.9 DAYS i I G,5 GPM cool MIN, 10 D4V*Y 3 �72, 5-00 GAL) &7J300 G,qt,) I 0 30op 60OD 700D' -i a `•B0 04 90 DO 1 p 1000 20.0D 3000 i0 O • f TELFAIR SUMMIT LOW DENSITY CALCULATIONS NON CURB & GUTTER SECTION OF VALLEY BROOK ROAD IMPERVIOUS SURFAQES: Pavement (1,100 LF x 20'W) = 0.51 AC. Site Area Impacted by Street = 16.96 AC. 0.51 _ 16.96 = 3.0% Impervious Area r is, . ,moo .----- 1 •=. StAL q� _ S38 _ Y.r LP Ei I i . •: 4���I��i nr, �,r•y SEITSPOND - 4 SA/DA - 85% TSS REMOVAL WITH 30' VEGETATIVE FILTER IMPER.% 3.OFT 3.5FT 4.OFT 4.5FT 5.OFT 5.5FT 6.OFT 6.5FT 7.OFT 7.5FT 10% .9 .8 .7 .6 .5 20% 1.7 1.3 1.2 1.1 1.0 .9 .8 .7 .6 .5 30% 2.5 2.2 1.9 1.8 1.6 1.5 1.3 1.2 1.0 .9 40% 3.4 3.0 2.6 2.4 2.1 1.9. 1.6 1.4 1.1 1.0 50% 4.2 3.7 3.3 3.0 2.7 2.4 2.1 1.8 1.5 1.3 60% 5.0 4.5 3.8 3.5 3.2 2.9 2.6 2.3 2.0 1.6 70% 6.0 5.2 4.5 4.1 3.7 3.1 2.9 2.5 2.1 1.8 80% 6.8 6.0 5.2 4.7 4.2 3.7 3.2 2.7 2.2 2.0 90% 7.5 6.5 5.8 5.3 4.8 4.3. 3.8 3.3 2.8 .1.3 100% 8.2 7.4 6.8 6.2 5.6 5.0 .4.4 3.8 3..2 2.6 SA/DA - > 90% TSS REMOVAL FOR WET DETENTION WITHOUT VEGETATIVE FILTER IMPER A 3.OFT 3.5FT 4.OFT 4.5FT 5.OFT 5.5FT 6.0FT 6.5FT 7.OFT 7.5FT 10% 1.3 1.0 .8 .7 .6 .5 .4 .3 .2 .1 20% 2.4 2.0 1.8 1.7 1.5 1.4 1.2 1.0 .9 .6 30% 3.5 3.0 2.7 2.5 2.2 - 1.9 1.6 1.3 1.1 .8 40% 4.5 4.0 3.5 3.1 2.8 2.5 1.8 1.4 1.1 50% 5.6 5.0 4.3 3.9 3:5 3.1 2.7 2.3' 1.9 1.5 60% '7.0 6.0 5.3 4.8 4.3 3.9 3.4 2.9 2.4 1.9 70% 8.1 7.0' 6.0 5.5' 5.0 .4.5 3.9 3.4 2.9 2.3 80% 9.4 8.0 7.0 6.4 5.7 5.2 4.6 4.0 3.4 2.8 90% 10.7 9.0 7.9 7.2 6.5 5.9 5.2 4.6 3.9 3.3 100% 12.0 10.0 8.8 8.1 7.3 6.6 -5.8 5.1 4.3 3.6 7ELFA)P- 5v/Y►017- JOSEPH S. HILL, JIL AND ASSOCIATES CONSULTING ENGINEERS and PLANNERS 1602 ILARBOIIR DRIVE WILMINGTON, NORTH CAROUNA TEL.1 PHOW 910.799-1544 October 22, 1996 Ms. Linda Lewis N.C.D.E.M. 127 Cardinal Drive Extension Wilmington, North Carolina 28405 Subject: Additional Information Stormwater Project No. SW8 960920 Telfair Summit New Hanover County ' Dear Ms. Lewis: MAII ING ADDRESS: POST OFFICE BOX 5592.STA. 1 WILMINGTON, NC 2W34155 S1111 T ink. 91-)� n P. 11 1419 41 , U 6 - "i � Tb� L� E C E I V E D OCT 2`21996 P R 0 J #�� "[l 0Q70 In response to your letter, we submit the following additional information regarding the Telfair Summit Stormwater Plan: 1. A topographic map with impervious areas clearly shown is enclosed. Development of the off -site drainage areas is complete (Linksider at The Cape and The Cape Golf Course). 2. The riser detail is revised to show 1.0' between the orifice and concrete ballast. 3. A note is added to the plans requiring all rooftop drains be directed to the pond. 4. Typical unit footprint is shown on building #6 with concrete steps and covered deck noted. Due to differences in step dimensions only, all left-hand unit are 2,040 SF, all right-hand units are 2,072 SF. 2,100 SF was used in calculations as the typical unit rooftop area. Driveways are 16' wide, but length varies. Therefore driveways are included (area calculations by planimeter) with street paving in impervious calculations. 5. The permanent pool elevation of 16.3' and storage pool elevation of 16.8' were reversed in the originally submitted calculations. Corrected copies of the calculations are enclosed. 6. Orifice size is increased to 2.5" 0. 7. Spot elevations and 6.0' depth contour (elevation 10.3') are shown for the existing bottoms of the ponds. 8. A forebay is shown at the pipe inlet. SEITSLEW IS2 Ms. Linda Lewis Telfair Summit October 22, 1996 Page 2 9. Buildings will be on pilings or elevated crawl spaces. With the street drainage routed through gutters to the catch basin near building 13, the small amount of driveway and front yard runoff can be routed around the buildings as shown, as is typically done where buildings pads are at or below street elevations. Please contact me if you have any questions. JSHlpat attachments Sincerely, JOSEPH S. HILL, JR. and ASSOCIATES a"�-5-` Josep S. Hill, Jr., P.E. SEITSLEWIS2 State of North Carolina Department of Environment, Health, and Natural Resources Wilmington Regional Office James B. Hunt, Jr. DIVISION OF WATER QUALITY Jonathan B. Howes Governor WATER QUALITY SECTION Secretary October 10, 1996 Mr. Joseph Hill, P.E. 1602 Harbour Drive Wilmington, North Carolina 28401 Subject: ADDITIONAL INFORMATION Stormwater Project No. SW8 960920 Telfair Summit New Hanover County Dear Mr. Hill: The Wilmington Regional Office received a Stormwater Management Permit Application for Telfair Summit on September 25, 1996. A preliminary review of that information has determined that the application is not complete. The following information is needed to continue the stormwater review: 1. Where is the 7.73 acres off -site area located. Three copies of a very dark, illegible map where provided. Please provide a better map with contours and impervious areas clearly shown. Also, -has the total build -out potential of the off -site runoff been taken into account? 2. The dimensions of the outlet structure do notadd up. If the orifice is at elevation 16.3, then based on the 2.5' concrete ballast, and .5' to the orifice, the entire height of the box would be 3.5' , not 4' . Please check and revise. 3. Note on the plans that all roof drains must be directed so that they drain to the pond. 4. Provide a typical unit footprint with dimensions, concrete areas, and wood decks noted. 5. The calculations report that the pond's surface area at 16.3 is more than the surface area at 16.8. Is this a mix-up? 6. The 2" orifice will draw down the pond in 5.8 days. Please revise and specify a larger orifice. 127 Cardinal Drive Extension, Wilmington, N.C. 28405-3845 • Telephone 910-395-3900 • Fax 910-350-2004 An Equal Opportunity Affirmative Action Employer Mr. Hill October 10, 1996 Stormwater Project No. SW8 960920 7_ Provide information on the existing bottom elevations of the ponds. 8. Construct a forebay prior to entering the pond without disturbing the pond any more than you already propose. 9. I am a little concerned with the proposed drainage around Units 13, 14, and 15. It appears that runoff will flow through front yards and drives prior to making it's way around and between the units and sheet flowing into the ponds. I anticipate many calls about flooded front yard, or water in people's houses. Please note that this request for additional information is' in response to a preliminary review. The requested information should be received by this Office prior to November 10, 1996, or the application will be returned as incomplete. The return of a project will necessitate resubmittal of all required items, including the application fee. If you have any questions concerning this matter please feel free to call me at (910) 395-3900. Sincerely, Ms. Linda Lewis Environmental Engineer JBBlarl: S:IWQSISTORMWATIADDINF01960920.00T cc: Linda Lewis Central Files 2 JOSEPH S. HILL, JIL AND ASSOCIATES CONSULTING ENGINEERS and PLANNERS 1602 HARBOUR DRIVE WILMINGTON, NORTH CAROUNA TEI,I'PHONG 910-799.1544 September 23, 1996 Ms. Linda Lewis N.C.D.E.M. 127 Cardinal Drive Extension Wilmington, North Carolina 28405 Subject: Telfair Summit Stormwater Management Plan New Hanover County Dear Ms. Lewis. MAIUUQADDRESS: POST OFFICE BOX 5592-STA. I WILMINGTON, NC 28403-4155 e, " �.-� SEp Enclosed are three (3) copies of the Telfair Summit Stormwater Management Plan. One (1) of the copies shows the drainage area to the stormwater pond in colored ink. Also included are two (2) copies each of the permit application, stormwater calculations, erosion control calculations, operation and maintenance schedule, and a check for the application fee of $385.00. The plan proposes use of two existing ponds that will be interconnected to serve as a single stormwater detention pond. All runoff from roof tops, driveways, and curb and gutter streets is routed to the pond. Runoff from the section of Valley Brook Road from Telfair's Creek to the beginning of the curb and gutter collection system near building 20 will flow directly from the road shoulders into the adjacent wetlands. Runoff from this street section is therefore not included in the detention pond calculations. Please review this plan as soon as possible. Please contact me if you have any questions. Sincerely, JOSEPH S. HILL, JR. and ASSOCIATES S,tka , JSHlpat Josep S. Hill, Jr., P.E. attachments SE/TSLEWISI