Loading...
HomeMy WebLinkAboutSW8980124_COMPLIANCE_20120130STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW OIc�I Y DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLAN; ❑ HISTORICAL FILE F,COMPLIANCE EVA DOC DATE 420laj YYYYMMDD AMMA NCDENR North Carolina Department of Environment and Division of Water Quality Beverly Eaves Perdue Charles Wakild, P. E. Governor Director January 30, 2012 Mr. Lawrence A. Wilson Jr. Wilson Family Realty, LLC 4925 New Centre Drive Wilmington, NC 28403 Subject: NOTICE OF INSPECTION Alleigh's Restaurant Stormwater Permit No. SW8 980124 New Hanover County Dear Mr. Wilson: Natural Resources Dee Freeman Secretary On September 23, 2011, David Cox of the Wilmington Regional Office of the Division of Water Quality (DWQ) inspected Alleigh's Restaurant in New Hanover County to determine compliance with Stormwater Management Permit Number SW8 980124 issued on May 6, 1998. DWQ file review and site inspection revealed that the site is not in compliance with the terms and conditions of this permit. Please find a copy of the completed form entitled "Compliance Inspection Report" attached to this letter, which summarizes the findings of the recent inspection. As indicated in the attached inspection report, the following deficiencies must be resolved: 1. Repair the forebay berm. 2. Install a trash rack and unclog the orifice of the outlet structure 3. Remove the trash from the pond and trim up the vegetation on the side slopes of the pond. Please inform this Office in writing before March 2, 2012, of the specific actions that will be undertaken and the time frame that will be required to correct the deficiencies. Failure to provide the requested information, or to respond to this letter by the due date, may initiate enforcement action including the assessment of civil penalties of up to $25,000 per day. If a written plan of action is not submitted to this office by March 2, 2012 then DWQ staff will re-inspect.the site and issue a Notice of Violation if the listed deficiencies have not been addressed. Wilmington Regional Office 127 Cardinal Drive Extension, Wilmington, North Carolina 28405 Phone: 910-796-72151 FAX: 910-350-20041 DENR Assistance: 1-877-623-6748 Internet: www,ncwaterquality.org One Aturallff hCarolina An Equal Opportunity 1 Attiirmative Action Employer State Stormwater Management Permit # SW8 980124 Please be reminded that if an ownership change, or a name change or a mailing address change has occurred, it is your responsibility to submit a completed and signed Name/Ownership Change form to the Division. Please include the name, mailing address and phone number of the party who is now responsible for this permit. If you have any questions, please contact me at the Wilmington Regional Office, telephone number (910) 796-7215. Sincerely, Davi ox Environmental Specialist Enc: Compliance Inspection Report GDSldwc: S:1WQS1StormwaterTermits & Projects11998\980124 HD12012 01 CEI deficient 980124 cc: Karen Higgins, WBS-CPU WiRO Stormwater File Georgette Scott Page 2 of 2 .✓ Compliance Inspection Report Permit: SW8980124 Effective: 05/06/98 Expiration: 05/06/08 Owner: Wilson Family Realty Inc Project: Alleigh's Restaurant County: New Hanover Region: Wilmington Contact Person: Lawrence A Wilson Title: Manager Directions to Project: Type of Project: State Stormwater - HD - Detention Pond Drain Areas: 1 - (Burnt Mill Creek) (03-06-23) { C;Sw) On -Site Representative(s): Related Permits: Inspection Date: 09/2312011 Entry Time: 03:30 PM Primary Inspector: David W Cox Secondary inspector(s): Reason for Inspection: Other Permit Inspection Type: State Stormwater Facility Status: ❑ Compliant ■ Not Compliant Question Areas: State Stormwater (See attachment summary) Exit Time: 04:30 PM Phone: Phone: 910-796-7215 Inspection Type: Compliance Evaluation Page: 1 u Permit: SW8980124 Owner - Project: Wilson Family Realty Inc Inspection Date: 09/2312011 Inspection Type: Compliance Evaluation Reason for Visit: Other Inspection Summary: In order for this pond to be deemed compliant please correct the fallowing: 1. Make the rapairs to the forebay berm. 2. Install trash rack and unclog orifice. 3. Remove trash and the trim the overgrown vegetation. Are the SW measures constructed as per the approved plans? ■ ❑ ❑ ❑ Are the inlets located per the approved plans? ■ ❑ ❑ ❑ Are the outlet structures located per the approved plans? ❑ ■ ❑ ❑ Comment: Outlet structure was observed to be clogged and the trash rack was missing Operation and Maintenance Yes No NA NE Are the SW measures being maintained and operated as per the permit requirements? ❑ ■ ❑ ❑ Are the SW BMP inspection and maintenance records complete and available for review or provided to DWQ ❑ ❑ ❑ ■ upon request? Comment: Trash in pond and the growth on pond slopes due to lack of maintenance. Site is not in business. Page: 2 Compliance Inspection Report Permit: SW8980124 Effective: 05/06/98 Expiration: 05/06/08 Owner: Wilson Family Realty Inc Project: Alleigh's Restaurant County: New Hanover Region: Wilmington Contact Person: Lawrence A Wilson Title: Manager Directions to Project: Type of Project: State Stormwater - HD - Detention Pond Drain Areas: 1 - (Burnt Mill Creek) (03-06-23 ) ( C;Sw) On -Site Representative(s): Related Permits: Inspection Date: 09123/2011 Entry Time: 03:30 PM Primary Inspector: David W Cox Secondary Inspector(s): Reason for Inspection: Other Permit Inspection Type: Slate Stormwater Facility Status: [ Compliant ■ Not Compliant Question Areas: 0 State Stormwater (See attachment summary) Exit Time: 04:30 PM Phone: Phone: 910-796-7215 Inspection Type: Compliance Evaluation Page: 1 Permit: Sw8980124 Owner - Project: Wilson Family Realty Inc Inspection Date: 0912312011 inspection Type: Compliance Evaluation Reason for Visit: Other Inspection Summary: in order for this pond to be deemed compliant please correct the following: 1. Make the rapairs to the forebay berm. 2. Install trash rack and unclog orfice. 3. Remove trash and the trim the overgrown vegetation. SW Measures Yes No NA N Are the SW measures constructed as per the approved plans? ■ ❑ ❑ ❑ Are the inlets located per the approved plans? ■ ❑ ❑ ❑ Are the outlet structures located per the approved plans? ❑ ■ ❑ ❑ Comment: Outlet structure was observed to be clogged and the trash rack was missing Operation and Maintenance Yes No NA NE Are the SW measures being maintained and operated as per the permit requirements? ❑ ■ ❑ Cl Are the SW BMP inspection and maintenance records complete and available for review or provided to DWQ ❑ ❑ ❑ ■ upon request? Comment: Trash in pond and the growth on pond slopes due to lack of maintenance. Site is not in business. Page: 2 W A r 4 `C September 2, 2008 Mr. Lawrence A. Wilson, Jr. Wilson Family Realty, LLC Wilson's Restaurant 4925 New Centre Drive Wilmington, NC 28403 NOTICE OF INSPECTION AND NON-COMPLIANCE Alleigh's Restaurant Stormwater Project No. SW8 980124 New Hanover County Dear Mr. Wilson: Michael F. Fasley, Governor Willimn G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Colcen H. Sullins Director [division of Water Quality Please find attached a copy of the completed form entitled "Stormwater Compliance Inspection Report". The report summarizes the findings of a recent inspection of the project's stormwater controls conducted on August 6, 2008 to determine compliance with Stormwater Permit Number SW8 980124 issued on May 6,1998. Photos taken during the inspection are located in Section 4 of this report and a summary of the required actions is noted under Section 5 of the report. Please inform this Office in writing before October 3, 2008, of the specific actions that will be undertaken and the time frame required to correct the deficiencies. Failure to provide the requested information, when required, may initiate enforcement action. If you have any questions please contact me at the Wilmington Regional Office, telephone number (910) 796-7215. Sincerely, Christine Nelson Environmental Engineer ENB/can: S:IWQSISTORMWA-RINSPECT1980124.aug08 cc: C_Wilmington- , _ional-Office Christine Nelson One NO thCarolina Naturally North Carolina Division of Water Quality 127 Cardinal Drive Extension Wilmington, NC 28405 Phone (910) 796-7215 Customer Service Wilmington Regional Office Internet: www.newaterquality.ore Pax (910)350-2004 1-877.623-6748 An.Equal Opportunity/Affirmative Action Employer — 50% Recycled110% Post Consumer Paper Lawrence A. Wilson, Jr. September 2, 2008 Stormwater Permit No. SW8 980124 STORMWATER COMPLIANCE INSPECTION REPORT 1 2. 3 Project Name: Alleigh's Restaurant Project Number: SW8 980124 Water Body: Smith Creek Control Measure: Wet Detention Pond Classification Directions to site, address: 4925 New Centre Dr., Wilmington Inspection Date: Weather Conditions Compliance Issues: August 6, 2008 sunny, hot, humid C, Sw Y N ®❑ The drainage area (including offsite) and built -upon area to the permitted system are per the approved plan. No unpermitted offsite drainage enters the system. ®❑ All the built -upon area associated with the project is graded such that the runoff drains to the system. ®❑ For pond, the outlet/bypass structure relative elevations are per the approved plan. (Must be verified via as -built survey if in question). ❑ ® The inlets and outlet structure are located per the approved plans and do not cause short-circuiting. ❑ ® A trash rack is provided over the outlet weir and orifice. ❑ ® All slopes are grassed with permanent vegetation and are not eroding. ❑ ® Vegetated slopes are no steeper than 3:1. ❑ ® The approximate amount of permitted surface area has been provided. ®❑ Required drawdown devices are correctly sized per the approved plans. All required design depths are provided. ®❑ All required parts of the system are provided, such as a vegetated shelf, and a forebay. ®❑ The designer's certification has been submitted. ®❑ The road, cul-de-sac, parking lot and sidewalk widths are per the approved plan. ❑ ® Required maintenance is being performed. Page 2of8 Lawrence A. Wilson, Jr. September 2, 2008 Stormwater Permit No. SW8 980124 4. Photos taken during the inspection on August 6, 2008- There appears to be excess sediment present in the forebay. Remove muskrat from property to prevent further damage to the pond side slopes. Three fountains are located within the main pond area. Owner informed inspectors that the fountains are likely '/z HP each. At the time of the inspection, only the 2 fountains closest to the forebay were working. Retaining wall was not installed along the inlet side of the forebay Page 3of8 Lawrence A. Wilson, Jr. Date A portion of the forebay berm has blown out. Several small wax myrtle trees were observed growing on the pond side slopes and vegetated shelf. Additional decking installed in excess of permit. The trash rack for the pond outlet was missing at the time of inspection. Page 4 of 8 Lawrence A. Wilson, Jr. Date Stormwater Permit No. SW8 980124 PVC pipes appear to have been installed to drain the patio area directly into the main pond. Additionally, it appears that the main roof drain from the building drains directly into the main pond. These inlets allow stormwater runoff to bypass the forebay and short circuit the pond. The orifice was clogged/plugged with debris at the time of the inspection. Owner unclogged orifice during the inspection. 5. Required Actions- (Explain each deficiency and what needs to be done to bring the system back into compliance) a. Remove trash and debris from the pond and outlet structure. b. Remove invasive shrubs and trees from pond side slopes and vegetated shelf. c. Several holes and areas of slight erosion were noted on the pond side slopes due to muskrat activities. Repair these areas as required in your permit. d. There appeared to be an accumulation of sediment in the forebay. The forebay and pond bottom levels should be checked and sediment should be removed, if required, according to your permit. e. The forebay berm appears to have been partially blown out and should be repaired and returned to design specifications. Page 5 of 8 Lawrence A. Wilson, Jr. Date Stormwater Permit No. SW8 980124 Section 11.4 of the stormwater permit issued May 6, 2008 prohibits the use of decorative spray fountains in the pond. If the fountains are desired to remain in the pond, the permit must be modified and the fountains located in permitted stormwater pond must meet the provided fountain guidance. Ponds with a permanent pool volume of less than 30,000 cubic feet are not permitted to have fountains. Please submit documentation that the pond fountains have been sized per the attached guidance. g. Replace the missing outlet structure trash rack. h. The retaining wall on the west side of the forebay was not constructed as approved. Please submit a revision to the approved plans. Additional inlets that were identified during the inspection were not included with the approved plan. Please submit a revision or build per the approved plans. Please continue to perform the required maintenance as instructed in the Operations and Maintenance Agreement. k. The business name has changed since the issuance of the permit. Please submit'a name/ownership change form to update the facility name listed on the permit. I. The stormwater permit expired on May 6, 2008 and no request for renewal has been received to date. Inspector: Pat Durrett and Christine Nelson Water Quality/Wilmington Regional Officel(910) 796-7215 ENBlcan: S:IWQSISTORMWATERIINSPECT1980124.aug08 Page 6 of 8 Lawrence A. Wilson, Jr. Date Stormwater Permit No. SW8 980124 Alleigh's Restaurant New Hanover County Stormwater Proiect No. SW8 980124 Designer's Certification I, , as a duly registered in the State of North Carolina, having been authorized to observe (periodically 1 weekly I full time) the construction of the project, (Project) for (Project Owner) hereby state that, to the best of my abilities, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications. Required Items to be checked for this certification to be considered complete are on page 2 of this form. Noted deviations from approved plans and specifications: Signature Registration Number Date SEAL cc: NCDENR DWQ Regional Office New Hanover County Building Inspector Page 7 of 8 Lawrence A. Wilson, Jr. Date Stormwater Permit No. SW8 980124 Certification Requirements: 1. The drainage area to the system contains approximately the permitted acreage. 2. The drainage area to the system contains no more than the permitted amount of built -upon area. 3. All the built -upon area associated with the project is graded such that the runoff drains to the system. 4. The outlet/bypass structure elevations are per the approved plan. 5. The outlet structure is located per the approved plans. 6. Trash rack is provided on the outlet/bypass structure. 7. All slopes are grassed with permanent vegetation. 8. Vegetated slopes are no steeper than 3:1. 9. The inlets are located per the approved plans and do not cause short- circuiting of the system. 10. The permitted amounts of surface area and/or volume have been provided. 11. Required drawdown devices are correctly sized per the approved plans. 12. All required design depths are provided. 13. All required parts of the system are provided, such as a vegetated shelf, and a forebay. 14. The dimensions of the system, as shown on the approved plans, are provided. CC' NCDENR-DWQ New Hanover County Building Inspector Page 8 of 8 r Date Design Andrew and Kuske ENGINEERS, INC. 902 Market 5t, Wilmington,N.C. 28401z 2SheetCONSULTING Check Job For Job No. Pa,.ja Ai-L65►t, 1-I's �Es-; 972so S'/7E ID _rA A ' 4, e4 A s/:6 A 9ZA 1t'C. Iz-Vi o uI A P-64 T1L0f, 26, e,o4D SF D E c le- 3 2 00 S F t�ttt�ii�rr,r! ,:,0:', C a Rp'`-- _ rA v8 1_! a $ o o S >` �� =�q�a�ESSrpy�•. 9 :r \VALK1 21 sou SEAL- ¢-s; Soo Sr • - �10972 �. y• .tr/j/l/+� N�f.• � "' I,,, C 1VC 5 L g„ 4, = 3.3¢ Ac-A, B4 Ac- ly{ •• / ���✓ � } G S go 1Ace6p_trious t/sG- 70�` noN0 SVRrAcE- AREA SA/OA - 3.9 "° 70, s- Tsr /G 04Ef&p // p }n )A-,P sa = 4, 84 A a, 034 o, I $S A� S 2 20 sF YA C- 6t.-6v 3(- _ /?/ /ou 5r 570QA C�C VOL-op,-& V-r(3'3�f AC 'e o,$)f C /,s A, ,t C3, o A. - F t o. 3 4� -Fir 0,Z76- /A, Ff /2, da a GF STORMWATER nE C E I V E uu MAR 1 01998 D D E M PROJ 4 { bate Design Andrew and KLtske Sheet 1 2111/S7 GL. r 902 Market St. CONSULTING ENGINEERS, INC. Wilmington, N.C. 28401 pt Check Job For Job No 5TO9r1z pa ,6 AjrL&I C H 'r `77z90 6C-e`/ 41z6A a vatr CL)r` VaC F T SF GF 3G 12,101) p 13, 400 1 ¢, $ 5`0 zSo 150 ! so 3S 1Sl,3oo ¢3, ¢oo )1J',V60 r- LEV 34 q = rzl loo Sr- g 22U s-r- ✓ f V= ,2� 0('C7 CF ,2ouo cF A= 12, lao SF ,t p,L �/= 12 00 C,= 2 4 Zm SF -REp',v =/ 4-0j CF IZC0'j-1y = 3 goo SF p<tov,p 1/= C� gov rL i t�( u mot)-)//t / 0. ' l ,4L4- \vA'j3L-f- V'S C OA IZG e - 2 JAY D�ZA\vo�iv. � 3 %go CF 1'r O p, 2. 0 A r t r 2Q Ile/t7AI o0 Scc/frK a, 07o cFY r OIL DR,F /c. 6. 42U T4-c7 h t/o , }} -0,,'l/Z o.4 0, 07 = a• G A 2, a,4i -rr �t r' L= 1.05_ rn. L Q V/S61I if 0 r ' I.03 V JL Z it) rN rn-�04C. Q t2 e C 0 Nye S "riz U C 'i, C, nv f Z U N OF ," } UVT1 Cu.. c G.a CF r ��� YftI Date Design Andrew and Kuske Sheet 902 Market St. CONSULTING ENGINEERS, INC. Wilmington, N.C. 28401 Of Z Check Job For Job No. $ 7 oK-c-""4 Ac L E �C, F! S Q65`� �l729'0 A= 4, e 4 A c- s/ « A 9-6 A 11 c'E17-v/0ul AREA BLu< Zee (aoa SF DEcIc 320o S>= PIAvE 1.1 0� $ oo sF \VAL.r- s 2 SO u SF A T- Sc o Sr- _ 3. 3 ¢ 4, 3.3¢ ;4c/¢. E?4 A-c. S %o l��YE�zvoUr 11 S G- 70 90 PoN0 SuRFAc.6- ARC -A STORMWATER D E C E I V E JAN 2 21998 D aaoda 5A loA = 3.9 '° 70 sb -rSr /G V,:�p /7o yo t�,P SA = 4, 84A, o, 1 Sly A,- = 822b -SF sA C- 6La\,- 3G _ /21 lou Sr ✓ 570IC44 C VoL�uru6 C3.0 A--F1 f o..7 A� 0.27s O� Ff 12� 060 Gf Hate Design Andrew and Kuske F7 G4- f 902 Morket St. CONSULTING ENGINEERS, INC. Wilmington. N.C. 28401 ;She2etZ1// Check Job For b No. STo\vr.17&-R Ton! gL.r.E+�N's 97z90 �L,EY 41z.6A a Y04 cJI,,,, V0(- FT SF e-F C-,2 i3 ¢6o / 37 1 4-17ov 13) 400 +¢� SSo 3 S /S, oo u 2 $� ZS0 3F 460 N\VL- cp F—L.45V 34 ,Q - /2/ Ica 3r 7 gzza r/= j/ 1 "57ort @ �4r;v 3G. y V= 1 2� 0(,() c F> 12 oo. c F A = 1lf,4¢0 sr ncinl, foa-6-13AY 0 6t-c.- 76 A= l2/ loo sF x 0.4 2 4-2.o 5F 1Z /� = 3 $eo SF ptzoV`p fiLLo�,V,913Lr< -74Y L7ZAwo0lvi✓ Q= /2,, 2 OArJ r 24 9P/DA>, 3400 j 66e- K b, 0 7 a cFS T 0Iz dRi/~/c-nvTc.c i 1 Q= C1, A s s A 0,07 = O. G A o, 41) A Ei9 sr x 14¢ rNIrF -rr �- O. 42. IN i U f& /. 2s" 1n/ �9 1-40L.c QrzC-00N1!�-rt?-uc70uw RUNar'i- Q- c 1 A G,r crs CDUTF�a,. "Fa v AI ' 1 U htl A' Data for 97290 ALLEIGHS RESTAURANT Page 1 TEN YEAR 24-HOUR RAINFALL= 7.0 IN Prepared by ANDREW & KUSKE CONSULTING ENGINEERS, INC. 11 Dec 97 HydroCAD 4.53_ 000479 (c)__1986-1997 Applied Microcomputer Svstems_ SUBCATCHMENT 1 SITE AREA TO POND PEAK= 24.79 CFS 9 12.08 HRS, VOLUME 1.30 AF ACRES CN SCS TR-20 METHOD 3.34 95 IMPERVIOUS AREA TYPE III 24-HOUR 1.50 39 OPEN, SOIL GROUP A RAINFALL= 7.0 IN 4.84 78 SPAN- 11-15 HRS, dt=.02 HRS Method Comment Tc (min) TR-55 SHEET FLOW PAVEMENT 2.5 Smooth surfaces n=.011 L=150' P2=4.5 in $=.005 CIRCULAR CHANNEL PIPE TO POND 4.0 24" Diameter a=3.14 sq-ft Pw=6.3' r=.5' s=.003 /' n=.013 V=3.94 fps L=940' Capacity=12.4 cfs Total Length= 1090 ft Total Tc= 6.5 24 22 20 18 j 16 4- u 14 12 3 10 Q .J 8 Lj- 6 4 2 0m SUSCATCHMENT 1 RUNOFF SITE AREA TO POND Ln m to m LO N N M M TIME Chours) AREA= 4.64 AC Tc= 6.5 MIN CN= 76 SCS TR-20 METHDD TYPE III 24-HOUR RAINFALL= 7.0 IN PEAK= 24.79 CF5 C 12.08 HRS VOLUME= 1.30 AF Data for 97290 ALLEIGHS RESTAURANT Page TEN YEAR 24-HOUR RAINFALL= 7.0 IN Prepared by ANDREW & KUSKE CONSULTING ENGINEERS, INC. 21 Jan 98 HydroCAD 4.53 000479 (c) 1986-1997 Applied Microcomputer Systems REACH 1 OUTLET PIPE TO SIGMON ROAD Qin = 6.04 CFS @ 12.49 HRS, VOLUME= .95 AF Qout= 6.04 CFS 0 12.49 HRS, VOLUME= .95 AF, ATTEN= 0k, LAG= .2 MIN DEPTH END AREA DISCH (FT) (SO-FTL-_ (CFS) 0.0 -0.0 0.00 .2 .1 .35 .3 .3 1.45 .5 .4 3.25 1.1 1.3 13.91 1.2 1.5 16.23 1.4 1.7 17.70 1.4 1.7 17.87 1.5 1.8 17.70 1.5 1.8 16.61 6.0 5.5 5.0 4,5 4.0 ko 3.5 3.0 I3 2.5 -1 2 0 Li- 1 .5 1.0 .5 0.0m 18" PIPE n= .013 LENGTH= 40 FT SLOPE= .025 FT/FT STOR-IND+TRANS METHOD PEAK DEPTH= .61 FT PEAK VELOCITY= 9.0 FPS TRAVEL TIME = .1 MIN SPAN= 11-15 HRS, dt=.02 HRS REACH I INFLOW 8 OUTFLOW OUTLET PIPE TO SIGMON ROAD 16" PIPE n=.013 L=40' 5=.025 OR-IND+TRANS METHOD in m to m in TIME (hours) UELOC€TY= 9 FPS TRAVEL= .I MIN �---.04 CFS 0.04 CFS .2 MIN Data for 97290 ALLEIGHS RESTAURANT Page 3 TEN YEAR 24-HOUR RAINFALL= 7.0 IN Prepared by ANDREW & KUSKE CONSULTING ENGINEERS, INC. 11 Dec 97 HydroCAD 4.53 000479 (c) 1986-1997 Applied Microcomputer Systems POND 1 DETENTION POND Qin = 24.79 CFS @ 12.08 HRS, VOLUME= 1.30 AF Qout= 6.04 CFS @ 12.49 HRS, VOLUME= .95 AF, ATTEN= 76%, LAG= 24.1 MIN ELEVATION AREA INC.STOR CUM.STOR STOR-IND METHOD (FT) (SF) (CF) (CF) PEAK STORAGE = 30137 CF 36.0 12100 0 0 PEAK ELEVATION= 38.1 FT 37.0 14700 13400 13400 FLOOD ELEVATION= 39.0 FT 38.0 15000 14850 28250 START ELEVATION= 36.0 FT 39.0 15300 15150 43400 SPAN= 11-15 HRS, dt=.02 HRS Tdet= 69 MIN (.94 AF) ## ROUTE INVERT _ OUTLET DEVIC_E_S 1 P 36.0' 1.31, ORIFICE/GRATE Q=.6 PI r"2 SQR(2g) SQR(H-r) 2 P 36.9' 4' x .3' ORIFICE/GRATE Q=•6 Width 2/3 SQR(29) (H-1.5 - [H-Height]"1.5) 3 P 38.2' 14' SHARP -CRESTED RECTANGULAR WEIR Q=C L H-1.5 C=3.27+.4 H/2 L=Length-O(.1 H) POND I INFLOW & OUTFLOW DETENTION POND 24 22 STOR-IND METHOD PEAK STOR= 32137 CF 29 PEAK E1_EU= 38.i FT 18 16 Din= 24.79 CFS Daut= 6.34 CF5 14 LAG= 24.1 MIN 12 � 10 J 8 6- 4 1� 2 1 ----- r Om Ln m Ln m Ln m Ln m Q' V Ln TIME (hours) Data for 97290 ALLEIGHS RESTAURANT Page 4 FIFTY YEAR 24-HOUR RAINFALL= 9.0 IN Prepared by ANDREW & KUSKE CONSULTING ENGINEERS, INC. 11 Dec 97 HydroCAD 4.53 000479 (c) 1986-1997 Applied Microcomputer Svstems SUSCATCHMENT i 464DwlZ4$inCom!x th7 PEAK= 34.65 CFS @ 12.08 HRS, VOLUME= 1.81. AF ACRES CN SCS TR-20 METHOD 3.34 95 IMPERVIOUS AREA TYPE III 24-HOUR 1.50 39 OPEN, SOIL GROUP A RAINFALL= 9.0 IN 4.84 78 SPAN= 11-15 HRS, dt=.02 HRS MethodComment Tc (min) TR-55 SHEET FLOW PAVEMENT 2.5 Smooth surfaces n=.011 L=150' P2=4.5 in s=.005 CIRCULAR CHANNEL PIPE TO POND 4.0 24" Diameter a=3.14 sq-ft Pw=6.3' r=.5' s=.003 /' n=.013 V=3.94 fps- L=940' Capacity=12.4 cfs Total Length= 1090 ft Total Tc= 6.5 34 32 30 28 26 r, 24 Ln 22 U 20 18 16 :3 }4 of 12 10 8 6 4 2 0m SUBCATCNMENT I RUNOFF SITE AREA TO POND Ln In to m in TIME (hours) AREA= 4.84 AC Tc= 6.5 MIN CN= 78 SCS TR-20 METHOD TYPE III 24-HOUR RAINFALL.= 9.0 IN PEAK= 34.65 CF5 e 12.38 HRS VOLUME:: 1.81 AF m Ln m V V Ln Data for 97290 ALLEIGHS RESTAURANT Pace FIFTY YEAR 24-HOUR RAINFALL= 9.0 IN Prepared by ANDREW & KUSKE CONSULTING ENGINEERS, INC. 21 Jan 98 HydroCAD 4.53 000479 (c) 1986-1997 Applied Microcomputer Systems REACH 1 OUTLET PIPE TO SIGMON ROAD Qin = 15.41 CFS Q 12.28 HRS, VOLUME= 1.43 AF Qout= 15.40 CFS @ 12.28 HRS, VOLUME= 1.43 AF, ATTEN= Ct, LAG= .1 MIN DEPTH END AREA DISCH (FT) (SO -FT) (CFS) 0.0 -0.0 0.00 .2 .1 .35 .3 .3 1.45 .5 .4 3.25 1.1 1.3 13.91 1.2 1.5 16.23 1.4 1.7 17.70 1.4 1.7 17.87 1.5 1.8 17.70 1.5 1.8 16.61 15 i4 13 12 it 'n 10 9 7 I1 6 O J 5 3 2 i Om 181, PIPE n= .013 LENGTH= 40 FT SLOPE= .025 FT/FT STOR-IND+TRANS METHOD PEAK DEPTH= 1.15 FT PEAK VELOCITY= 10.7 FPS TRAVEL TIME = .1 MIN SPAN= 11-15 HRS, dt=.02 HRS REACH I INFLOU & OUTFLOW OUTLET PIPE TO SIGMON ROAD 16" PIPE n=,013 L=40' S=.025 STOR-IND+TRANS METHOD UELOCITY= 10.7 FPS TRAUEL= .I MIN Din= 15.41 CFS Oout= 15.40 CFS LAG= .1 MIN Lr) m Ln m Ln N N TIME (hours) m n m v V Lf5 Data for 97290 ALLEIGHS RESTAURANT Page 6 FIFTY YEAR 24-HOUR RAINFALL= 9.0 IN Prepared by ANDREW & KUSKE CONSULTING ENGINEERS, INC. 11 Dec 97 H droCAD 4.53 000479 c 1986-1997 Applied Microcomputer Systems POND 1 DETENTION POND Qin = 34.65 CFS Q 12.08 HRS, VOLUME= 1.81 AF Qout= 15.41 CFS @ 12.28 HRS, VOLUME= 1.43 AF, ATTEN= 56`>;, LAG= 12.0 MIN ELEVATION AREA INC.STOR CUM.STOR STOR-IND METHOD (FT) (SF) (CF) (CF) PEAK STORAGE = 36073 CF 36.0 12100 0 0 PEAK ELEVATION= 38.5 FT 37.0 14700 13400 13400 FLOOD ELEVATION= 39.0 FT 38.0 15000 14850 28250 START ELEVATION= 36.0 FT 39.0 15300 15150 43400 SPAN= 11-15 HRS, dt=.02 HRS Tdet= 59.6 MIN (1.43 AF) # ROUTE INVERT OUTLET DEVICES 1 P 36.01 1.31, ORIFICE/GRATE Q=.6 PI r-2 SQR(2g) SQR(H-r) 2 P 36.9' 4' x .3' ORIFICE/GRATE Q=.6 Width 2/3 SQR(2g) (H-1.5 - [H-Height]^1.5) 3 P 38.2' 14, SHARP -CRESTED RECTANGULAR WEIR Q=C L H- .5 C=3.27+.4 H/2 L=Length-O(.1 H) POND 1 INFLOW & OUTFLOW DETENTION POND 34 32 STOR-IND METHOD 30 PEAK STOR= 36073 CF 28 PEAK ELEV= 38.5 FT 26 24 Oin= 34.65 CFS 22 Oovt= 15.41 CFS u 20 LAG= 12 MIN ,� 18 16 73 14 r p 12 � 10 r B i ` 6 2 em m L m Ln m Ln m TIME (hours) NC:DDO�T�RepOft Iv - YEAR Pipe -Node Upstream Downstream Inlet Area (acres) Inlet TC (min) Inlet Discharge (cfs) Total CA (acres) -Ground- Upstream Downstream (ft) -HGL- Upstream Downstream (ft) -Slope- Energy Constructed M -Section- Discharge Capacity (cfs) -Section- Shape Size Length (ft) Average Velocity (Sus) P-9 1-9 0.33 10,00 1,68 0,26 39.00 37.84 0.13 1.681 Circular 93.00 2.13 1-8 39.00 37.72 0.22 2.15 12 inch P-8 1-8 0.38 10.00 1,93 0.57 39.00 37.72 0.06 3.54 Circular 160.00 2.17 1-3 40.30 37.64 0.19 5.91 18 inch P-7 1-7 0.38 10,00 1.93 0.30 41.00 38.09 0.33 1.93 Circular 157.00 3.22 1-4 41,00 37.73 0.70 3,88 12 inch P-6 1-6 0.46 10.00 2.34 0.37 40.60 38.05 0,11 2.34 Circular 153.00 2.57 1-5 40.70 37.96 0.26 4.29 15 inch P-5 1-5 0.38 10.00 1.93 0.67 40,70 37.96 0.10 4.15 Circular 275.00 2.81 1-4 41.00 37.73 0,18 5.82 18 inch P-4 1-4 0.35 10.00 1.78 1,26 41.00 37.73 0.09 7,41 Circular 128.00 3.20 1-3 40.30 37.64 0.16 11.62 24 inch P-3 1-3 0,60 10.00 3.05 2.30 40.30 37.64 0.15 13.33 Circular 119.00 4.49 1-2 40.10 37.48 0.17 21.86 30 inch P-2 1-2 0.31 10.00 1.57 2.55 40.10 37.48 0.15 14.58 Circular 172.00 4.53 1-1 39.40 37.31 0.20 24.05 30 inch P-1 1-1 0.49 10.00 2.49 2.94 39.40 37.31 0.18 16.50 Circular 85,00 4,12 Outlet I I I 1 139.001 37.161 0.181 28.02 136 inch P_rojg9c EEngirleer: LARRY,'SNEEDEN StormCAD v1?0 551166fi P.age;;1"of..j NqD B, po, 2S-YEAR Pipe -Node- Upstream Downstream Inlet Area (acres) Inlet TC (min) Inlet Discharge (cfs) Total CA (acres) -Ground- Upstream Downstream (ft) -HGL- Upstream Downstream (ft) -Slope- Energy Constructed M) -Section- Discharge Capacity (cfs) -Section- Shape Size Length (ft) Average Velocity (fis) P-9 1-9 0.33 10.00 1.90 0.26 39.00 38.06 0.17 1.90 Circular 93.00 2.42 1-8 39.00 37.90 0.22 2,15 12 inch P-8 1-8 0.38 10.00 2,18 0.57 39.00 37.90 0.08 4.01 Circular 160.00 2.30 1-3 40.30 37.77 0.19 5.91 18 inch P-7 1-7 0.38 10.00 2.18 0.30 41.00 38.13 0.26 2.18 Circular 157.00 3.48 1-4 41,00 37.87 0.70 3.88 12 inch P-6 1-6 0.46 10,00 2.64 0.37 40.60 38.25 0.10 2.64 Circular 153.00 2.41 1-5 40.70 38.14 0,26 4.29 15 inch P-5 1-5 0.38 10,00 2.18 0.67 40,70 38.14 0.11 4.69 Circular 275A0 2.84 1-4 41.00 37.87 0.18 5.82 18 inch P-4 1-4 0.35 10,00 2.01 1.26 41.00 37,87 0,09 8.38 Circular 128.00 3.27 1-3 40.30 37,77 0.16 11,62 24 inch P-3 1-3 0.60 10.00 3.45 2.30 40.30 37.77 0.15 15.08 Circular 119.00 4,55 1-2 40.10 37.62 0,17 21.86 30 inch P-2 1-2 0.31 10,00 1,78 2.55 40.10 37.62 0,15 16.48 Circular 172.00 4.64 1-1 39.40 37.44 0.20 24.05 30 inch P-1 1-1 0.49 10.00 2.82 2.94 39.40 37.44 0.18 18.66 Circular 85.00 4.24 Outlet I I I 1 139.001 37.291 0.18 28,02 36 inch Project` Engineer;-LARRY!SNEEDEN SITEWORKS:DESIGN;GROUP, StormCADs.v1i0 Brookside'Road._,�Watotr u_ry",ICTa06708i11SA "E203)755=1666 Page;,l-Iof;1 NnmRepo .To -y6AR Pipe -Node- Upstream Downstream Inlet Area (acres) Inlet TC (min) Inlet Discharge (cfs) Total CA (acres) -Ground- Upstream ❑ownsiream (ft) -HGL- Upstream Downstream (ft) -Slope- Energy Constructed (%) -Section- Discharge Capacity (cfs) -Section- Shape Size Length (ft) Average Velocity (fUs) P-9 1-9 0.33 10.00 2.07 0.26 39.00 38.25 0.20 2.07 Circular 93.00 2,64 1-8 39.00 38.06 0.22 2.15 12 inch P-8 1-8 0,36 10.00 2.39 0.57 39.00 38.06 0.10 4.39 Circular 160.00 2.48 1-3 40.30 37.89 0.19 5.91 18 inch P-7 1-7 0.38 10.00 2.39 0.30 41.00 38.39 0.26 2.39 Circular 157.00 3.13 1-4 41.00 38.00 0,70 3,88 12 inch P-6 1-6 0,46 10.00 2.89 0.37 40.60 38.57 0.12 2.89 Circular 153.00 2.35 1-5 40.70 38.38 0.26 4.29 15 inch P-5 1-5 0.38 10.00 2.39 0.67 40.70 38.38 0.14 5.12 Circular 275.00 2.90 1-4 41.00 38.00 0.18 5.82 18 inch P-4 1-4 0.35 10.00 2.20 1.26 41.00 38.00 0.10 9.16 Circular 128.00 3.32 1-3 40.30 37,89 0.16 11.62 24 inch P-3 1-3 0.60 10.00 3.77 2.30 40.30 37.89 0.14 16.49 Circular 119.00 4.59 1-2 40.10 37.74 0.17 21.86 30 inch P-2 1-2 0.31 10.00 1,95 2.55 40.10 37.74 0.15 18.03 Circular 172.00 4.72 1-1 39.40 37.55 0,20 24.05 30 inch P-1 1-1 0.49 10.00 3.08 2.94 39.40 37.55 0.18 20A2 Circular 85.00 4.32 Outlet 39.00 37.40 1 0.18 28.02 1 36 inch P.roject:l"nglne-LLARR_Y.SNEEDEN StormCADw,1:0 55:166 Paged_' 1, 01/21/98 M52:59` M