HomeMy WebLinkAboutSW6190903_Plan (Ex. Conditions)_20190930IMPERVIOUS AREA
EXISTING TRACT 1
PRE-DEVELOPEMENT
TOTAL AREA = 22,538.26 SF
EXISTING IMPERVIOUS AREA = 15,748.96 SF
% IMPERVIOUS AREA = 70.689%
POST -DEVELOPMENT
TOTAL AREA = 22,538.26 SF
PROPOSED IMPERVIOUS AREA = 5,354.36 SF
% IMPERVIOUS AREA = 23.75%
PIN: 794830101026
JESSE WHEELER
DB 226 P 555
ZONED: RA-20
IMPERVIOUS AREA
EXISTING TRACT 2
PRE-DEVELOPEMENT
TOTAL AREA = '68,522.18 SF
EXISTING IMPERVIOUS AREA = 1,487.26 SF
% IMPERVIOUS AREA = 2.17%
POST -DEVELOPMENT
TOTAL AREA = 68,522.18 SF
PROPOSED IMPERVIOUS AREA = 32,493.41 SF
% IMPERVIOUS AREA = 47.42%
EXISTING 6"
CONCRETE CURB
EXISTING SIGN
L=45.47'
R=46.30'
CHORD=S23'55'57"W
CH. LENGTH=43.66'
CONTRACTOR SHALL SAW CUT
AND REMOVE ONLY THE
EXISTING CONCRETE CURB
REQUIRED TO INSTALL NEW TURN
RADIUS. 'Q' PIN• 794830101025
p
PIN: 794830101013 20
LINFIELD PARTNERS, LLC
DB 1216 P 770
ZONED: NB QC7
Q- QJ
Q
,moo
Q7
5111►12[1MM=lMile] OW,
IMPERVIOUS AREA
COMBINED TRACT
PRE-DEVELOPEMENT
TOTAL AREA = 91,060.44 SF
EXISTING IMPERVIOUS AREA = 17,236.22 SF
% IMPERVIOUS AREA = 18.92%
POST -DEVELOPMENT
TOTAL AREA = 91,060.44 SF
PROPOSED IMPERVIOUS AREA = 37,847.77 SF
% IMPERVIOUS AREA = 41.56%
EASEMENT TO AT&T, DB 365,
PG 694, 5' WEST OF FIRST LAID
CABLE AS INDICATED BY
SURFACE MAREKINGS
EDGE OF EXISTING
ASPHALT DRIVE
75.00'
2 10'53
w
ASPHALT
PARKING
0 ct $s
� 1
� l
1
TRACT 1
00 EXISTING �
SEPTIC
\ \ FIELD x
PIN: 794830101068
DAVIS BRIDGE ENTERPRISES, LLC \ \
DB 1233 P 102E EXISTING SEPTIC \�°s\ /- o`O/?
ZONED: NB SYSTEM AND 1999s�-�/�
FIELD TO REMAIN \ \°o
NEAL HOLDINGS, LLC /
�O rsy G
DB 1264 P 721-723 GOB
ZONED: NB
PHASE 2
e,� /DEMOLITION
ASPHALT
'PARKING i
BUILDING
SETBACK LINE
1. SITE SHALL BE CLEARED AS NOTED ON PLAN, OF ALL OBSTRUCTIONS AND
DELETERIOUS MATERIAL SUCH AS GAS TANKS, PIPES, FENCES, WALLS, FOUNDATIONS,
LOGS, SHRUBS, BRUSH, WEEDS, AND OTHER VEGETATION. THIS MATERIAL SHALL BE
SATISFACTORILY DISPOSED OF OFF -SITE.
2. THE LOCATION OF EXISTING UTILITIES, SUCH AS WATER MAINS, SEWERS, GAS LINES,
ETC., AS SHOWN ON THE PLANS HAVE BEEN DETERMINED FROM THE BEST AVAILABLE
INFORMATION AND ARE GIVEN FOR THE CONVENIENCE OF THE CONTRACTOR. THE
ENGINEER AND OWNER ASSUME. NO LIABILITY FOR ITS ACCURACY AND COMPLETENESS.
IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONTACT ALL UTILITY COMPANIES 48
HOURS PRIOR TO COMMENCEMENT OF CONSTRUCTION AND HAVE THEIR FACILITIES
LOCATED IN THE FIELD PRIOR TO ANY WORK.
3. PRIOR TO ANY CONSTRUCTION OR LAND DISTURBING ACTIVITIES, CONTRACTOR SHALL
VERIFY THAT DESIGN PLANS FOR CONSTRUCTION ARE SIGNED, SEALED AND DATED BY
DOUBLE D ENGINEERING, PLLC.
REVISIONS
SYM. DESCRIPTION DATE O U b l e
n ineerin , PLLC
J J
150 S. Page Street . Southern Pines, NC 28387• (910) 684-8646 . Cert. No. P--1275
PIN: 794830101010
JOESPH RIDDLE III
DB 534 P 617
ZONED: NB
TBM: EXISTING IRON PIN
N: 436869.5150
E: 1983668.5270
ELEV. 135.92'
SR 1003 ARABIA ROAD (601 R/W) PUBLIC
— 1;66—
X057106"8' — ..� 84.38'
E N 52°5747" E
EXISTING DUMPED CONCRETE
EXISTING WOOD
FENCE
EXISTING WELL HOUSE
ABANDONED
.6�,.�1oSEP
SANITARYSEWER WE AR ND \`
DRAINFIELD EASEMENT
PB 354, PG 3
BUILDING
SETBACK LINE
PIN: 79483010121E TWO EDO D AREA
NEAL HOLDINGS, LLC �
DB 1264 P 719-720
ZONED: NBIRA-20
EXISTING WOOD
LINE
TRACT 2
FA
....................
S 77°
4��
PIN: 794830101069
DAVID CARLSON
DB 972 P 629
ZONED: NB
�����..+NNMM0 Pz z l
�a'aGES51n:'.9
` SEAL i
9570
114
PHASE 1
DEMOLITION
EXISTING FIBER
OPTIC LINE
STR EAM DATA:
ROCKFISH CREEK
SURFACE FRESHWATER CLASSIFICATION: B
RIVER BASIN: CAPE FEAR: INDEX 18-31-(18)
SITE IS NOT IN A FEMA FLOOD PLAIN PER FIRM PANEL
MAP NO. 3710948300L - DATE: 1 /5/07
YARD/BUFFER DIMENSIONS:
EXISTING SETBACKS (NB):
A) BUILDING SETBACK FRONT: 10' MINIMUM
B) EXTERIOR SIDE SETBACK: 5' MINIMUM
C) REAR SETBACK: 25' MINIMUM
EXISTING SETBACKS (RA-20):
A) BUILDING SETBACK FRONT: 30' MINIMUM
B) EXTERIOR SIDE SETBACK: 10' MINIMUM
C) REAR SETBACK: 25' MINIMUM
ZONING AREA
ZONING: NB
ZONING: RA-20
SOIL DATA
SOIL CLASSIFICATION:
BaB: BLANEY LOAMY SAND
2 TO 8 PERCENT SLOPES
JT: JOHNSTON LOAM
TOPOGRAPHY SURVEY BY:
TERRY FAIRCLOTH, PLS
2017 FALLOW R U N
FAYETTEVILLE, NC 28312
(910) 494-7444
.. .�
i L • .► V.
TOTAL DISTURBED AREA
PHASE 1 56,893 SF 1.30 AC
PHASE 2 17,592 SF 0.403 AC
GENERAL INFORMATION:
PROJECT OWNERS:
NEAL HOLDINGS, LLC
CHRIS NEAL
1007 ARSENAL AVENUE
FAYETTEVILLE, NC 28305
\ 910-433-4490
m.
a'
0 J.
10' LANDSCAPE BUFFER.
z' CONTRACTOR SHALL LEAVE ALL
TREES 2" CALIPER AND LARGER
o'
60
w
b a'� EXISTING WELL
1v HOUSE
GO
' PIN: 794830101217
WOODED AREA VIVIAN DODSON
DB 663 P 024
ZONED: RA-20
\-BUILDING
SETBACK LINE
S 46- 23 4 t, w
102.3T
SHORT STOP GAS STATION
HOKE COUNTY, NORTH CAROLINA
SCALE: 1" = 10'
10' 0 5' 10' 20'
EXISTING CONDITIONS AND DUNE/2019
DEMOLITION PLAN I DATE
PRELIMINARY DRAWINGS
C-1
FOR REVIEW ONLY
SHEET iVO.