Loading...
HomeMy WebLinkAboutSW6190903_Plan (Ex. Conditions)_20190930IMPERVIOUS AREA EXISTING TRACT 1 PRE-DEVELOPEMENT TOTAL AREA = 22,538.26 SF EXISTING IMPERVIOUS AREA = 15,748.96 SF % IMPERVIOUS AREA = 70.689% POST -DEVELOPMENT TOTAL AREA = 22,538.26 SF PROPOSED IMPERVIOUS AREA = 5,354.36 SF % IMPERVIOUS AREA = 23.75% PIN: 794830101026 JESSE WHEELER DB 226 P 555 ZONED: RA-20 IMPERVIOUS AREA EXISTING TRACT 2 PRE-DEVELOPEMENT TOTAL AREA = '68,522.18 SF EXISTING IMPERVIOUS AREA = 1,487.26 SF % IMPERVIOUS AREA = 2.17% POST -DEVELOPMENT TOTAL AREA = 68,522.18 SF PROPOSED IMPERVIOUS AREA = 32,493.41 SF % IMPERVIOUS AREA = 47.42% EXISTING 6" CONCRETE CURB EXISTING SIGN L=45.47' R=46.30' CHORD=S23'55'57"W CH. LENGTH=43.66' CONTRACTOR SHALL SAW CUT AND REMOVE ONLY THE EXISTING CONCRETE CURB REQUIRED TO INSTALL NEW TURN RADIUS. 'Q' PIN• 794830101025 p PIN: 794830101013 20 LINFIELD PARTNERS, LLC DB 1216 P 770 ZONED: NB QC7 Q- QJ Q ,moo Q7 5111►12[1MM=lMile] OW, IMPERVIOUS AREA COMBINED TRACT PRE-DEVELOPEMENT TOTAL AREA = 91,060.44 SF EXISTING IMPERVIOUS AREA = 17,236.22 SF % IMPERVIOUS AREA = 18.92% POST -DEVELOPMENT TOTAL AREA = 91,060.44 SF PROPOSED IMPERVIOUS AREA = 37,847.77 SF % IMPERVIOUS AREA = 41.56% EASEMENT TO AT&T, DB 365, PG 694, 5' WEST OF FIRST LAID CABLE AS INDICATED BY SURFACE MAREKINGS EDGE OF EXISTING ASPHALT DRIVE 75.00' 2 10'53 w ASPHALT PARKING 0 ct $s � 1 � l 1 TRACT 1 00 EXISTING � SEPTIC \ \ FIELD x PIN: 794830101068 DAVIS BRIDGE ENTERPRISES, LLC \ \ DB 1233 P 102E EXISTING SEPTIC \�°s\ /- o`O/? ZONED: NB SYSTEM AND 1999s�-�/� FIELD TO REMAIN \ \°o NEAL HOLDINGS, LLC / �O rsy G DB 1264 P 721-723 GOB ZONED: NB PHASE 2 e,� /DEMOLITION ASPHALT 'PARKING i BUILDING SETBACK LINE 1. SITE SHALL BE CLEARED AS NOTED ON PLAN, OF ALL OBSTRUCTIONS AND DELETERIOUS MATERIAL SUCH AS GAS TANKS, PIPES, FENCES, WALLS, FOUNDATIONS, LOGS, SHRUBS, BRUSH, WEEDS, AND OTHER VEGETATION. THIS MATERIAL SHALL BE SATISFACTORILY DISPOSED OF OFF -SITE. 2. THE LOCATION OF EXISTING UTILITIES, SUCH AS WATER MAINS, SEWERS, GAS LINES, ETC., AS SHOWN ON THE PLANS HAVE BEEN DETERMINED FROM THE BEST AVAILABLE INFORMATION AND ARE GIVEN FOR THE CONVENIENCE OF THE CONTRACTOR. THE ENGINEER AND OWNER ASSUME. NO LIABILITY FOR ITS ACCURACY AND COMPLETENESS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONTACT ALL UTILITY COMPANIES 48 HOURS PRIOR TO COMMENCEMENT OF CONSTRUCTION AND HAVE THEIR FACILITIES LOCATED IN THE FIELD PRIOR TO ANY WORK. 3. PRIOR TO ANY CONSTRUCTION OR LAND DISTURBING ACTIVITIES, CONTRACTOR SHALL VERIFY THAT DESIGN PLANS FOR CONSTRUCTION ARE SIGNED, SEALED AND DATED BY DOUBLE D ENGINEERING, PLLC. REVISIONS SYM. DESCRIPTION DATE O U b l e n ineerin , PLLC J J 150 S. Page Street . Southern Pines, NC 28387• (910) 684-8646 . Cert. No. P--1275 PIN: 794830101010 JOESPH RIDDLE III DB 534 P 617 ZONED: NB TBM: EXISTING IRON PIN N: 436869.5150 E: 1983668.5270 ELEV. 135.92' SR 1003 ARABIA ROAD (601 R/W) PUBLIC — 1;66— X057106"8' — ..� 84.38' E N 52°5747" E EXISTING DUMPED CONCRETE EXISTING WOOD FENCE EXISTING WELL HOUSE ABANDONED .6�,.�1oSEP SANITARYSEWER WE AR ND \` DRAINFIELD EASEMENT PB 354, PG 3 BUILDING SETBACK LINE PIN: 79483010121E TWO EDO D AREA NEAL HOLDINGS, LLC � DB 1264 P 719-720 ZONED: NBIRA-20 EXISTING WOOD LINE TRACT 2 FA .................... S 77° 4�� PIN: 794830101069 DAVID CARLSON DB 972 P 629 ZONED: NB �����..+NNMM0 Pz z l �a'aGES51n:'.9 ` SEAL i 9570 114 PHASE 1 DEMOLITION EXISTING FIBER OPTIC LINE STR EAM DATA: ROCKFISH CREEK SURFACE FRESHWATER CLASSIFICATION: B RIVER BASIN: CAPE FEAR: INDEX 18-31-(18) SITE IS NOT IN A FEMA FLOOD PLAIN PER FIRM PANEL MAP NO. 3710948300L - DATE: 1 /5/07 YARD/BUFFER DIMENSIONS: EXISTING SETBACKS (NB): A) BUILDING SETBACK FRONT: 10' MINIMUM B) EXTERIOR SIDE SETBACK: 5' MINIMUM C) REAR SETBACK: 25' MINIMUM EXISTING SETBACKS (RA-20): A) BUILDING SETBACK FRONT: 30' MINIMUM B) EXTERIOR SIDE SETBACK: 10' MINIMUM C) REAR SETBACK: 25' MINIMUM ZONING AREA ZONING: NB ZONING: RA-20 SOIL DATA SOIL CLASSIFICATION: BaB: BLANEY LOAMY SAND 2 TO 8 PERCENT SLOPES JT: JOHNSTON LOAM TOPOGRAPHY SURVEY BY: TERRY FAIRCLOTH, PLS 2017 FALLOW R U N FAYETTEVILLE, NC 28312 (910) 494-7444 .. .� i L • .► V. TOTAL DISTURBED AREA PHASE 1 56,893 SF 1.30 AC PHASE 2 17,592 SF 0.403 AC GENERAL INFORMATION: PROJECT OWNERS: NEAL HOLDINGS, LLC CHRIS NEAL 1007 ARSENAL AVENUE FAYETTEVILLE, NC 28305 \ 910-433-4490 m. a' 0 J. 10' LANDSCAPE BUFFER. z' CONTRACTOR SHALL LEAVE ALL TREES 2" CALIPER AND LARGER o' 60 w b a'� EXISTING WELL 1v HOUSE GO ' PIN: 794830101217 WOODED AREA VIVIAN DODSON DB 663 P 024 ZONED: RA-20 \-BUILDING SETBACK LINE S 46- 23 4 t, w 102.3T SHORT STOP GAS STATION HOKE COUNTY, NORTH CAROLINA SCALE: 1" = 10' 10' 0 5' 10' 20' EXISTING CONDITIONS AND DUNE/2019 DEMOLITION PLAN I DATE PRELIMINARY DRAWINGS C-1 FOR REVIEW ONLY SHEET iVO.