Loading...
HomeMy WebLinkAboutNCG030227_Tier Relief Request_20201222Geosynte& consultants Geosyntec Consultants of NC, P.C. 2501 Blue Ridge Road, Suite 430 Raleigh, NC 27607 PH 919.870.0576 www.geosyntec.com December 22, 2020 To: Ms. Tamera Eplin, PE, CPESC Regional Engineer Land Quality Section, Winston-Salem Regional Office Division of Energy, Mineral and Land Resources North Carolina Department of Environmental Quality 450 West Hanes Mill Road, Suite 300 Winston-Salem, NC 27105-7407 tamera.eplin@ncdenr.gov Subject: Request for Regulatory Relief and Approval to Resume Semi -Annual Monitoring for Corning Optical Communications, LLC Winston-Salem Facility (NPDES Permit No. NCG030227) Dear Ms. Eplin: The Corning Optical Communications, LLC (Corning) Winston-Salem facility (the Site) is a fiber optic cable manufacturing facility located at 3180 Centre Park Boulevard in Winston-Salem, North Carolina. Stormwater discharges from the Site are regulated by National Pollutant Discharge Elimination System (NPDES) Certificate of Coverage No. NCG030227 under the State of North Carolina General Permit No. NCG030000 for Metal Fabrication (NCG03), which covers the facility's standard industrial code (SIC) 34 (Fabricated Metal Products). The Site entered Tier Three status in September 2018 due to copper (Cu) and zinc (Zn) exceedances at Outfall 002 after a facility expansion. No copper (Cu) or zinc (Zn) benchmark exceedances have occurred at either of the Site outfalls since January 2019. On November 24, 2020, representatives from Corning and Geosyntec Consultants of NC, P.C. (Geosyntec) had a teleconference with North Carolina Department of Environmental Quality (NCDEQ) Regional Engineering Associate Zachary Lentz, PE, to discuss the process for approval to returning to semi-annual monitoring. This letter serves as a formal request for regulatory relief from Tier Three status and approval to resume semi-annual monitoring. GN6958/CAR200178 NCDEQ_Relief Request Final engineers I scientists I innovators Tamera Eplin, PE, CPESC 22 December 2020 Page 2 SITE BACKGROUND The Site is delineated into two watersheds (see Attachment A: Figure 1). The eastern portion of the Site drains to Outfall 001 and includes administrative buildings and parking facilities; limited industrial activity occurs in the watershed draining to Outfall 001. The western portion of the Site drains to Outfall 002 and comprises a majority of the industrial activity from the facility. An expansion on the western side of the facility (which drains to Outfall 002) occurred in September 2017; galvanized gutters were installed as a part of this warehouse expansion activity. The Cu and Zn concentrations in the samples collected at Outfall 002 during the December 2017 and April 2018 semi-annual sampling events exceeded the benchmarks of the then -applicable 2012 NCG03 permit, which were 7 micrograms per liter (µg/L) and 67 µg/L for Cu and Zn, respectively. This triggered Tier Two status, and Corning began collecting samples from both Outfalls on a monthly basis beginning in June 2018. While under Tier Two status, Cu exceedances occurred at Outfall 002 in July 2018 and September 2018 and Zn exceedances occurred at Outfall 002 in July 2018 and October 2018. Because there were four exceedances at an Outfall within the permit period, Tier Three status was triggered. Tier Three status requires ongoing monthly monitoring until relieved by NCDEQ. It is notable that the NCG03 permit was reissued on November 1, 2018 with higher benchmarks; the increased benchmarks are 10 µg/L and 126 µg/L for Cu and Zn, respectively. Of the four samples at Outfall 002 which triggered Tier Three status, only the September 2018 Cu result at Outfall 002 exceeded the increased 2018 benchmarks. Tier Three status would not have been triggered if the existing permit were in effect prior to November 2018. MONTHLY MONITORING RESULTS Monthly sampling commenced in June 2018 after entering Tier Two status. Corning endeavored to sample monthly, but samples could not be collected during some months due to the lack of a qualifying rainfall event within the sampling period or the absence of rainfall -generated runoff at the Outfalls. Certifications of no discharge for those periods are provided in the Discharge Monitoring Reports (DMRs) in Attachment B. Laboratory results to support the DMRs are also provided in Attachment B. A summary of Cu and Zn concentrations from December 2017 to September 2020 is provided in Table 1. Figures 2 and 3 display these data graphically for Outfall 001 and Outfall 002, respectively. The June 2018, July 2018, and September 2018 samples were analyzed at both GN6958/CAR200178 NCDEQ_Relief Request Final engineers I scientists I innovators Tamera Eplin, PE, CPESC 22 December 2020 Page 3 TestAmerica and Prism Laboratories; both results are presented in Table 1. After September 2018, all collected samples were analyzed at TestAmerica. Results from the monthly sampling events indicate concentrations at both Outfalls have been below the benchmark values identified in the latest issuance of NCG03 for nearly two years, with eight consecutive events in compliance since January 2019. Furthermore, no Zn exceedances have been observed at Outfall 001 for over 2 years, with twelve consecutive events in compliance since September 2018. These monthly results suggest the Cu and Zn exceedances that led to Tiered monitoring status may have been due to temporary leaching from new building materials introduced during the facility expansion in September 2017, and levels of Cu and Zn have now declined sufficiently to below the present benchmarks. Table 1. Summary of Outfall Sampling from June 2018 — September 2020 while in Tier Two and Tier Three status. Date Laboratory Cu (µg/L) Zn (µg/L) Applicable Benchmark Outfall 001 Outfall 002 Applicable Benchmark Outfall 001 Outfall 002 Dec-17 Prism 7 < 5 12 67 77 160 Apr-18 Prism 7 7.9 13 67 55 120 Jun-18 Prism 7 < 5 < 5 67 75 54 TestAmerica 7 3.2 4.6 67 37 45 Jul-18 Prism 7 7.9 7.7 67 96 87 TestAmerica 7 5.0 5.0 67 72 68 Sep-18 Prism 7 < 5 13/< 54 67 < 65 < 65 TestAmerica 7 2.3 2.1 67 38 49 Oct-18 TestAmerica 7 2.2 4.6 67 29 100 Nov-18 TestAmerica 10 2.2 3.8 126 30 40 Dec-18 TestAmerica 10 18 17 126 68 180 Jan-19 TestAmerica 10 3.6 3.2 126 25 30 Mar-19 TestAmerica 10 5.4 B 2.3 B 126 62 48 Apr-19 TestAmerica 10 2.3 4.6 126 33 59 May-19 TestAmerica 1 10 3.8 9.0 126 48 1 81 Oct-19 TestAmerica 10 2.6 2.2 126 30 58 Jan-20 TestAmerica 10 2.0 2.2 126 29 60 GN6958/CAR200178 NCDEQ_Relief Request Final engineers I scientists I innovators Tamera Eplin, PE, CPESC 22 December 2020 Page 4 Date Laboratory Cu (µg/L) Zn (µg/L) Applicable Benchmark Outfall 001 Outfall 002 Applicable Benchmark Outfall 001 Outfall 002 Apr-20 TestAmerica 10 4.0 9.4 1 126 43 110 Sep-20 TestAmerica 10 2.3 5.5 1 126 30 82 Notes: 1. Blue shading indicates exceedance of the applicable benchmark value. 2. A less -than symbol (<) indicates the parameter was not detected above the associated reporting limit. 3. B indicates the parameter was not detected substantially above the level reported in the laboratory blanks. 4. The June 2018, July 2018, and September 2018 samples were analyzed at both Prism and TestAmerica Laboratories. The September 2018 Outfall 002 Prism sample was re -analyzed for Cu due to the discrepancy observed between the original Prism result and the TestAmerica result; the concentration of Cu in the second analysis was not detected above the reporting limit, and the laboratory was not able to provide a reasoning for this. Because of these discrepancies, all samples after September 2018 were analyzed at TestAmerica. INVESTIGATION INTO METALS SOURCES In accordance with the requirements outlined in the Tiered response actions, Corning evaluated possible causes of the benchmark value exceedances through Site reconnaissance, investigative stormwater sampling, and development of a conceptual site model of potential metals sources and transport pathways. Corning performed three rounds of investigative sampling since the September 2017 facility expansion. The investigative sampling occurred in June 2018, October 2019, and September 2020. Samples were collected from various potential source areas contributing to the Outfalls (see Figure 1); sample locations were categorized as representing either non -industrial sources (e.g., downspouts from rooftops, parking areas) or industrial sources (e.g., storm drains receiving runoff from industrial areas, such as equipment storage, transport, or loading areas). In the September 2020 round of sampling, samples were analyzed for both dissolved and total metals to evaluate what portion of metals was particulate -bound as opposed to dissolved. Evaluating both total and dissolved metals is useful for refining the conceptual site model of potential sources and transport mechanisms. Results from the investigative sampling are provided in Table 2. GN6958/CAR200178 NCDEQ_Relief Request Final engineers I scientists I innovators Tamera Eplin, PE, CPESC 22 December 2020 Page 5 Table 2. Summary of Investigative Sampling Results. Cu (µg/L) Zn (Ng/L) Location Description P Source Discharge Point Date Applicable Applicable Benchmark Total Dissolved Benchmark Total Dissolved Jun-18 7 6.3 - 67 100 - DS-1 Downspout Non- Outfall 002 Oct-19 10 - 1.2 126 - 130 at Dock industrial Sep-20 10 3.9 3.3 126 260 250 Jun-18 7 < 2 - 67 160 - DS-2 Downspout Non- Outfall 002 Oct-19 10 - < 2 126 - 76 at Canopy industrial Sep-20 10 < 2 < 2 126 210 180 FPL-1 Front Non- Outfall001 Sep-20 10 2.7 2.1 126 17 15 Parking Lot industrial Storm Drain Oct-19 10 - 1.2 126 - 34 SD-1 at Reel Industrial Outfal1 002 Storage Sep-20 10 11 5.4 126 140 36 Area Storm Drain Oct-19 10 - < 2 126 - 37 SD-2 at Loading Industrial Outfall 002 Area Sep-20 10 1.7 1.2 126 73 64 Notes: 1. Blue shading indicates exceedance of the applicable benchmark value. 2. Dashes indicate the parameter was not analyzed. The October 2019 investigative samples were not analyzed for total metals due to analytical errors. 3. A less -than symbol (<) indicates the parameter was not detected above the associated reporting limit. GN6958/CAR200178 NCDEQ_Relief Request Final engineers I scientists I innovators Tamera Eplin, PE, CPESC 22 December 2020 Page 6 Based on the results from these investigative samples, rooftops and galvanized gutters on the western side of the facility were found to be a potential non -industrial source of Zn to Outfall 002. Zn concentrations measured at the gutter downspouts (100 — 260 µg/L) were up to two times greater than the current NCG03 Zn benchmark value (126 µg/L). The dissolved fraction of metals at both downspouts ranged from 85 — 96%, indicating the metals present in runoff from these source areas are not particulate -bound. However, these contributions do not presently cause an exceedance of Cu or Zn at Outfall 002. The investigative sampling also found that industrial activity on the western side of the facility is a potential moderate industrial source of Zn, with concentrations from the reel storage area and loading area ranging from 73 — 140 µg/L (approximately 57% - 111 % of the benchmark value). The reel storage area could also be a modest industrial source of Cu (up to 110% of the benchmark value). Neither source presently causes exceedances at Outfall 002 for Cu or Zn. The front parking lot was not an apparent source of metals concentrations. This non -industrial source does not presently cause exceedances at Outfall 001 for Cu or Zn. These findings suggest past exceedances in Cu and Zn at the Site likely originate from the facility expansion in September 2017, which introduced new non -industrial sources to the Site (e.g., galvanized gutters). Within 15 months of the facility expansion, Cu and Zn declined to levels below present benchmark values, suggesting that remaining industrial and non -industrial sources of metals still present at the Site do not cause Outfall exceedances. Corning has also emphasized to Site construction teams the importance of material selection in mitigating potential non- industrial sources during future facility improvements. ATTACHMENTS The following attachments are provided as documentation to this request: • Attachment A: Figures o Figure 1: Site Overview and Sampling Locations o Figure 2: Copper and Zinc Concentrations at Outfall 001 o Figure 3: Copper and Zinc Concentrations at Outfall 002 GN6958/CAR200178 NCDEQ_Relief Request Final engineers I scientists I innovators Tamera Eplin, PE, CPESC 22 December 2020 Page 7 • Attachment B: Discharge Monitoring Reports (DMRs) and Laboratory Results from December 2017 — October 2020. CLOSING Corning has shown consistent compliance with NCG03 benchmarks at both Outfalls 001 and 002 since January 2019. Corning also conducted several rounds of investigative sampling to evaluate the potential sources of past Cu and Zn exceedances. The results from the investigative sampling indicate the highest concentrations of metals at the Site are generated from non -industrial sources (e.g., galvanized gutters). For these reasons, Corning requests regulatory relief from Tier Three status and approval to resume semi-annual monitoring. Sincerely, Alessandra Braswell, PhD, PE (NC) Project Engineer Geosyntec Consultants of NC, P.C. Attachments: Attachment A: Figures Attachment B: Discharge Monitoring Reports and Laboratory Results (December 2017 — October 2020) Copies to: Zachary Lentz, PE, North Carolina Department of Environmental Quality Ronica Edgerton, Corning Optical Communications, LLC Jennifer Adams, Corning Optical Communications, LLC Peter de Haven, PE (NC, GA), Geosyntec Consultants of NC, P.C. GN6958/CAR200178 NCDEQ_Relief Request Final engineers I scientists I innovators ATTACHMENT A Figures ., q OA°A°A°A°A°O�♦ ♦AAAAAAAAAA� ♦AAAAAAAAAAA� * iAAAAAAAAAAAA♦ /AAAAAAAAAAAAA� ♦AAAAAAAAAAAA♦ ►sssssssssssss� ��< +ssossssss� °s°s°s°s°s°s°s°s°� >ssssssss� - ' ►°i°i°i°i°i°i' F ♦ssss♦ #, - ►sssAIIWA � ♦ssss•sAss. °i2i�i �s°►� ►°s°s°i�o�s�.°i°s°s`. ►��y,►�asAM°:As,►sQ►°ass°s�, D ��A°®A°°°°U°A°E,�'°A°°AAA iAAAA�AAA�EAA���aAA6�A°AAs� FA MA 'IVA a►�s� �.-ys°s°i°i°s�► .� ♦9U6Av3A�A��AAAA► �A®AAA►`°�AAs4As?�AA,�rAAAAAAA�A� " �iAJAAAA� �AAAvAvA-�►A6AAAAt► �AAE AA 9firs dr.090% ►pA�AWiA�A�AAAAAO� ���,�>r�i<yg�3A�AA��►ASAAASAAAAAr�� ► . p ,►+>ASAO<>•ASAAASAAASAAASASA®A°� °.°°°,�°° °°°° :i51 �•►°A►AAAAA♦ ♦A� �4ArAAAU►AAAAA��iAA�� -a��1AAAA���o�O1AAA1 ♦AAAAAAAI , t L�►°AAAAAAAAAAA97 p gi Compliance Sample Locations Drainage Areas Roof Materials Notes: 1. Locations are approximate. ® Outfall Outfall 001 EPDM 2. Orthoimagery obtained from NC OneMap Site Map data.nconemap.gov 20190303 N ® Outfall 002 0 EPDM and ballast 3. EPDM - Ethylene Propylene Diane Corning Optical Communications LLC Centre Park Boulevard Investigative Sample Locations NHD Flowline 0 TPO Terpolymer Winstnston-Salem, North Carolina 4. NHD - National Hydrography Dataset ® Downspout Stream / River Corrugated Metal 5. TPO -Thermoplastic Polyolen Geosyntec° GeosyntecConsultantsofNC,P.C. Figure ®fi Storm Drain consultants NC License No.: C-3500 and C-295 ® Front Parking Lot 0 400 Feet 1 Raleigh, NC December 2020 N:\C\Corning\Winston Salem\GIS\MXD\Fig1-NCDEQ Letter.mxd 12/14/2020 2:33:58 PM 300 — 275 — 250 225 200 J CA r_ 175 0 150 c 0 125 a 100 • 75 • • • • • 50 • • • 0 • • • • Jul-17 Dec-17 May-18 Oct-18 Mar-19 Aug-19 Jan-20 Jun-20 Nov-20 • Zinc • Copper Zinc Benchmark Copper Benchmark Facility Expansion Notes: Copper and Zinc Concentrations at Outfall 001 1. Benchmarks prior to November 2018 were 7 µg/L and 67 µg/L for Copper and Zinc, respectively. Corning Optical Communications, LLC Facility 2. Benchmarks applicable after November 2018 are 10 µg/L and 126 µg/L for Copper and Zinc, respectively. Winston-Salem, North Carolina 3. Analytical results that were not detected above the reporting limit are plotted at half the reporting limit. 4.The June 2018, July 2018, and September 2018 samples were analyzed at both Prism and TestAmerica Laboratories. Geosynte& Geosyntec Consultants of NC, P.C. Figure consultants NC License No.: C-3500 and C-295 2 Raleigh December 2020 300 — 275 — 250 225 200 J CA 175 0 v 150 c 0 125 m • 100 • 75 50 • • 25 0 • • • Jul-17 Dec-17 May-18 Oct-18 Mar-19 Aug-19 Jan-20 Jun-20 Nov-20 • Zinc • Copper Zinc Benchmark Copper Benchmark Facility Expansion Notes: Copper and Zinc Concentrations at Outfall 002 1. Benchmarks prior to November 2018 were 7 µg/L and 67 µg/L for Copper and Zinc, respectively. Corning Optical Communications, LLC Facility 2. Benchmarks applicable after November 2018 are 10 µg/L and 126 µg/L for Copper and Zinc, respectively. Winston-Salem, North Carolina 3. Analytical results that were not detected above the reporting limit are plotted at half the reporting limit. 4.The June 2018, July 2018, and September 2018 samples were analyzed at both Prism and TestAmerica Laboratories. GeosyntecO Geosyntec Consultants of NC. P.C. Figure consultants NC License No.: C 3500 and C 295 3 Raleigh December 2020 ATTACHMENT B Discharge Monitoring Reports and Laboratory Results DECEMBER 2017 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Qu lity eneral Permit No. NCG030000 Date submitted CERTIFICATE OF COVERAGE NO. NCGQ3 99 FACILITY NAME e.r COUNTY �Vy_ PERSON COLLECTING 5AMPLAvsa�� .a LABORATORYA�O� L�r/f'.. Lab Cert. #.Z Comments on sample collection or analysis: Part A: Storrnwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR /7 SAMPLE PERIOD ❑ Jan -June July -Dec or ❑ Monthly' (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA []Zero -flow ]Water supply ❑SA []Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 EJ No discharge this period?2 Outfall No. Date Sample Collected' {mo/dd/yr) 24-hour rainfall amount, lnches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organics5 Benchmarks =__> _ - 100 mg/L or 50 mg/0 6.0 — 9.0 0.007 mg/L 0.033 mg/L 0.067 mg/L 15 mg/L 1 mg/L t 1 3 , Q lik L. op p 1 Monthly sampling (instead of semi-annual) must beginwith the second consecutive benchmark exceedance for the same parameter at the same outfall. Z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469,22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit I( 11/1/2012-10/31/2017 / 5WU-245, last revise,_ �/25/2012 Page 1of3 Ajc:- Laboratory Report IS M Full -Service Analylicaf& Environmental Solutions 1212012017 ueOn�rowlEi +r1c Corning Cable Systems Attn: Darren Swart 3180 Centre Park Blvd. Winston Salem, NC 27107 Project: Stormwater Client Sample ID: Outfall ##1 Prism Sample ID: 7120127-01 Prism Work Order: 7120127 Sample Matrix: Water Time Collected: 12/05/17 20:30 Time Submitted: 12/06/17 15:50 Parameter Result Units Report MDL Dilution Method Analysis Analyst Batch Limit Factor Date/Time ID General Chemistry Parameters Oil a Grease (5GT-HEM) BRLpG mg/L 5.0 1.1 1 1664E 12/14/17 8:44 SLS P71-0242 pH 6.6 HT pH Units 1 'SM4500-H B 1216117 16:40 BMS P71-0120 Total Suspended Solids 9.8 mg1L 3.1 0.40 1 'SM2640 D 12/11117 13:16 SLS P71-0173 Total Metals Copper BRL ug1L 5.0 0.22 1 '6020B 12/14/17 17:30 EGG P71-0226 Lead 1.2 ug/L 1.0 0.093 1 '6020B 12114117 17:30 EGC P71-0226 Zinc 77 uglL 10 2.8 1 *60208 121/4/17 17:30 EGC P71-0226 This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240643 • Charlotte, NC 28224-0643 Phone: 7041529-6364 - Toll Free Number: 1-800/629-6364 - Fax: 704/526-0409 Page 4 o 88 '\' Laboratory Report r Pi a Full -Service Anaiytical & R I qM Environmanlal solutions 12/20/2017 Corning Cable Systems Project: Stormwater Client Sample ID: Outfall #2 Attn: Darren Swart Prism Sample ID: 7120127-02 3180 Centre Park Blvd. Prism Work Order: 7120127 Winston Salem, NC 27107 Sample Matrix: Water Time Collected: 12/05/17 20:32 Time Submitted: 12/06/17 15:50 Parameter Result Units Report MDL Dilution Method Analysis Analyst Batch Limit Factor Date/Time ID General Chemistry Parameters Oil & Grease (SGT-HEM) BRLOO mg/L 5.0 1.1 1 '1664B 12114/17 9:14 SLS P7L0242 pH 9.3 HT pH Units 1 'SM4500•H B 12/6117 16:40 BMS P71-0120 Total Suspended Solids 59 mg/L 8.3 0.40 1 'SM2540 D 12/11/17 13:39 SLS P71-0173 Total Metals Copper 12 ug/L 5.0 0.22 1 '6020B 12/14/17 17:63 EGC P71-0226 Lead 4.8 ug/L 1.0 0.093 1 '60208 12/14/17 17:53 EGC P71-0226 Zinc 160 ug/L 10 2.8 1 '6020B 12/14/17 17:53 EGC P71-0226 This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0643 Phone: 704/529-6364 - Toll Free Number: 1-8001529-6364 - Fax: 7041525-0409 Page 5 of 8 APRIL 2018 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 05/24/2018 CERTIFICATE OF COVERAGE NO. NCG03 0 2 2 7 FACILITY NAME Corning Cable Systems COUNTY . __F—QLWh PERSON COLLECTING SAMPLES Jamie Joines LABORATORY Prism Laboratories,Inc- Lab Cert. # 402 Comments on sample collection or analysis: Part A. Stor.mwater Benchmarks and Monitoring Results SAMPLE COLLECTIO YEAR 2018 SAMPLE PERIOD MJan-June ❑ July -Dec or ❑ Monthly' {month) DISCHARGING TO CLASS ❑ORW ❑HQW []Trout ❑PNA []zero -flow ❑Watersupply ❑SA ❑Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ❑ No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper � Lead zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organics, genchmarks ==_> _ - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.033 mg/L 0.067 mg/L 15 mg/L 1 mg/L 1 04/23/2018 2.16 16 m /L 6.4 0.008 <0.001 0.055 <5.0 N/A 2 04/23/2018 2.16 33 m /L 7.7 0.013 0.002 0.120 <5.0 N/A 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. ° See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. s Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit I( 11/1/2012-10/31/2017 l SWU-245, last revise /25/2012 ` Page 1 of 3 t.\ Laboratory Report '!P R. I qM I Fullironmee Analytical sEnvironmentef Soluliom 05/11/2018 - un Corning Cable Systems Project: Stormwater Client Sample ID: SW -1 Attn: Jamey Joins Prism Sample ID: 8040559-01 3180 Centre Park Blvd. Prism Work Order: 8040559 Winston Salem, NC 27107 Sample Matrix: Water Time Collected: 04/23/18 14:00 Time Submitted: 04/27/18 1&50 Parameter Result Units Report IVIDL Dilution Method Analysis Analyst Batch Limit Factor Date/Time ID General Chemistry Parameters Oil & Grease {SGT-HEM} BRL pG mg/L 5.0 1.1 1 1664E 519118 12:08 SLS P8E0191 Total Suspended Solids 16 mglL 6.2 0.40 1 ISM2640 D 4130/13 10,48 COP P8D0613 Total Metals Copper 7.9 ug1L 6.0 0,22 1 '6020B 611118 16:02 PJF PBE0004 Lead BRL uglL 1.0 0,093 1 '6020B 51108 16:02 PJF P8E0004 Zinc 65 ugrL 10 2.8 1 '6020B 611119 16:02 PJF POE0004 This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratones, Inc. 449 Spring brook Road . P,p, Box 240543 - Charlotte, NC 28224-0543 Phone: 704l629-0364 - Toll Free Number: 1-800/529-0364 - Fax: 7041626-0409 Page 4 of 8 Pr R+ ISM /w' Fuli-Service Analytical 8 R [ 1 Y 1 Environmental Solutions 1�LIIarA�TORIF$ WC Corning Cable Systems Attn: Jamey Joins 3180 Centre Park Blvd, Winston Salem, NC 27107 Laboratory Report 05/ 11 /2018 Project: Stormwater Client Sample ID: SW - 2 Prism Sample ID: 8040559-02 Prism Work Order: 8040559 Sample Matrix: Water Time Collected: 04/23/18 14:10 Time Submitted: 04/27/18 16:50 Parameter Result Units Report MDL Dilution Method Analysis Analyst Batch Limit Factor Datef ime ID General Chemistry Parameters Oil & Grease (SGT-HEM) BRLpG mg1L 5.0 1.1 1 '1664B 5/10118 8:24 SLS PBE0245 Total Suspended Solids 33 mg1L 6.2 0.40 1 '$M2540 0 4/30118 10:48 CBP PBD0613 Total Metals Copper 13 uglL 5.0 0.22 1 '6020B 511118 1610 PJF P8E0004 Lead 2.2 uglL 1.0 0.093 1 '6020B 511118 16:10 PJF P8E0004 Zinc 120 ug1L 10 2.8 1 '6020B 611118 16:10 PJF PBE0004 This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240643 -Charlotte, NC 28224.0543 Phone: 7041629-6364 - Toll Free Number: 14001929.6364 - Fax: 7041625-0409 Page 5 of 8 JUKE 2018 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 08/03/2018 CERTIFICATE OF COVERAGE NO. N0003 0 2 2 7 FACILITY NAME Corning Cable Systems --'-' COUNTY Forsyt PERSON COLLECTING SAMPLES Jamie Joines LABORATORY Test America Lab Cert. # 434 Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2018 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or 9Monthlyl June_monthl DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA ❑Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 � ❑ No discharge this period?Z ,.outfall No. _ Date Sample - Collected (mo/dd/yr) 24-hour rainfall _amount, Inches3 Total Suspended Solids pH, Standard units• Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organics s Benchmarks ===> - - 100 mg/L or 50 mg/L 6.0 - 9.0 0.007 mg/L 0.033 mg/L 0.067 mg/L 1s mg/L 1 mg/L 1 06/25/2018 0.17 6.3 mg/L 7.3 0.003 <0.001 0.037 <1.3 N/A 06/25/2018 0.17 6.5 mg/L 7.8 0.005 <0.001 0.045 < 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here, 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. See General Permit, Table 3 identifying the especiallysensitivereceiving water classifications where the more protective benchmark applies. s Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit 11/l/2012-10/31/2017 SWU-245, last revise' '125/2012 Page 1 of 3 Client Sample Results Client: Michael Baker International, Inc. Project/Site. Stormwater, Winston Salem, NC TestAmerica Job ID: 180-79284-1 Client Sample ID: OUTFALL 01 Lab Sample ID: 180-79284-1 Date Collected: 06/25/18 08:40 Matrix: Water Date Received: 06127/18 09:35 Method: EPA 6020A - Metals (ICPIMS) - Total Recoverable Analyte Result Qualifier RL MDL Unit D Prepared Analyzed DO Fac Copper 3.2 2.0 1.3 ug1L 06128/1814:17 07/0711811:57 1 Lead 0.71 J 1.0 0.094 ug/L 06128/1814:17 0710711811:57 1 Zinc 37 5.0 2.4 ug/L 0612811814:17 0710711811:57 1 General Chemistry Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac HEM ND 3.7 1.3 mg/L 0711211811:05 0711211811:05 1 SGT-ITEM ND 3.7 1.3 mg/L 0711211811:05 0711211811:05 1 r Total Suspended Solids 6.3 0.50 0.50 mg/L 06/29/18 08:28 1 Analyte Result Qualifier RL RL Unit D Prepared Analyzed Dil Fac pH 6.7 HF 0.1 0.1 SU 06129/18 08:35 1 Client Sample ID. OUTFALL 02 Lab Sample ID: 180-79284-2 Date Collected: 06/25/18 08:50 Matrix: Water Date Received: 06127/18 09:35 Method: EPA 6020A - Metals (ICPIMS) - Total Recoverable Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac Capper 4.6 2.0 1.3 ug/L 0612811814:17 07/0711812:00 1 Lead 0.67 J 1.0 0.094 ug/L 06128/1814:17 07107/1812:00 1 Zinc 45 5.0 2.4 ug/L 06128/1814:17 0710711812:00 1 General Chemistry Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac HEM ND 4.0 1,4 mg1L 0711211811!05 07112/1811:05 1 SGT-HEM ND 4.0 1.4 mg/L 0711211811:05 0711211811:05 1 Total Suspended Solids 6.5 0.50 0.50 mg/L 06129/18 08:28 1 I Analyte Result Qualifier RL RL Unit D Prepared Analyzed Dill Fac pH 7.4 HF 0.1 0.1 SU 06129/18 08:35 1 Client Sample ID: DOCK DS Lab Sample ID: 180-79284-3 Date Collected. 06/25/18 09:05 Matrix: Water Date Received: 06/27118 09:35 Method: EPA 6020A - Metals (ICPIMS) - Total Recoverable Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac Copper 6.3 2.0 1.3 ug/L _ 06/2811814:17 07/07/1812:03 1 Lead 0.27 J 1.0 0.094 ug/L 06/28/18 14,17 07/0711 a 12:03 1 Zinc 100 5.0 2.4 ug/L 0612811814:17 07/07/1812:03 1 Client Sample ID: CANOPY DS Lab Sample ID: 180-79284-4 Date Collected, 06125/18 09:00 Matrix: Water Date Received: 06/27/18 09:35 Method: EPA 6020A - Metals (ICPIMS) - Total Recoverable Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Di Fac Copper NO 2.0 1.3 ug1L 06/28/18 14:17 07/07/18 t 2:06 1 Lead 0.33 J 1.0 0.094 ug1L 0612811814:17 07107/1812:06 1 Zinc 160 5.0 2.4 ug1L 06/28/1814:17 07/07/1812:06 1 TestAmerica Pittsburgh Page 11 of 20 7/12/2018 Laboratory Report Pa sfFult-Service Analytical & oft e I S M i EnVNOnmentar Solutions A "07I1212018 ,`+t'tnadnAiomeE iMG Corning Cable Systems Project: Stormwater Client Sample IQ: Outfall #1 Attn: Jamey Joines Prism Sample ID: 8060393-01 3180 Centre Park Blvd, Prism Work Order: 8060393 Winston Salem, NIC 27107 Sample Matrix: Water Time Collected: 06/25/18 20:40 Time Submitted: 06/28/18 12:00 Parameter Result Units Report MDL Dilution Method Analysis Analyst Batch Limit Factor Date/Time ID General Chemistry Parameters Oil 6 Grease (SGT-HEM) BRLpr, mg/L 5.0 1.1 1 16646 713118 12:06 SLS P8G0031 P14 5.9 NT pH units 1 -SM4600-H B 6128118 16:03 CBP P8F0483 Total Suspended Solids 3.0 mg1L. 2.6 0.40 1 'SM2640 0 6129118 13:44 CSP P8F0496 Total Metals Copper BRL ug/L 5.0 0.22 1 '6020B 7/10/18 1:14 JAB P8G0034 Lead 2.2 ug1L 1.0 0.093 1 '6020B 7110/18 1:14 JAB PBG0034 Zinc 75 ug1L 10 2.6 1 '6020B 7110118 1:14 JAB PBG0034 This report should not be reproduced, except in its entirety, without the written consent at Prism Laboratories, Inc, 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 704162M364 -Toll Free Number: 1-B001529-6364 - Fax: 704162"409 Page 3 of 7 /fik"NE, Fun-Service Analytleal b I S M I Environmental Solutions Laboratory Report 07/12/2018 Corning Cable Systems Project: Stormwater Client Sample ID: Outfall 92 Attn; Jamey Joines Prism Sample ID: 8060393-02 3180 Centre Park Blvd, Prism Work Order: 8060393 Winston Salem, NC 27107 Sample Matrix: Water Time Collected: 06125/18 20:50 Time Submitted: 06/28/18 12:00 Parameter Result Unite Report M1DL dilution Method Analysis Analyst Batch Limit Factor RateMme ID General Chemistry Parameters , Oil & Grease (SGT-HEM) BRLOG mg1L 5.0 1.1 1 "1664B 7/3118 12:06 SLS PBG0031 pH 6.9 HT pH Units 1 'SM4600-H B 6128118 16:03 CBP P8F0483 Total Suspended Solids 6.8 mg1L 3.2 0.40 1 'SM2640 D 6129118 13:44 CBP P8F0496 Total Metals Copper BRL ug1L 5.0 0.22 1 '6020B 7110116 1:42 JAB PBG0034 Lead BRL u91L 1.0 0.093 1 '6020B VWM6 1:42 JAB PBG0034 Zinc 64 u911- 10 2-8 1 160209 7110118 1:42 JAB POG0034 This report should not be reproduced, except in Its entirety, without the written consent of Prism Laboratories. Inc. 449 Springbrook Road - P.O. Box 240643 - Charlotte, NC 28224.0643 Phone: 704/629-6364 - Toll Free Number: 1-8001629.6364 - Fax: 7041625-0409 Page 4 of 7 JULY 2018 Semi-annual Stormwater Discharge Monito_ring.Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 09/03/2018 CERTIFICATE OF COVERAGE NO. NCG03 0 2 2 7 FACILITY NAME Corning Cable SysTems — -""' COUNTY Forsyth PERSON COLLECTING �A�IIPLFIS Jamie Joines LABORATORY r�sm a ora o Lab Cert. # 402 Comments on sample collection or analysis: Part A. Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2018 SAMPLE PERIOD [] Jan -June ❑ July -Dec or &fMunthly' Ju Y month DISCHARGING TO CLASS ❑ORW ❑HQW []Trout ❑PNA []Zero -flow []Water Supply (]SA []Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 � F] No discharge this period Outfall No. Date Sample p Collected' (mo/dd/yr) 24-hour rainfall amount, inches Total Suspended Solids pH, Standard units Copper Lead � Zinc Non -Polar O&G/ Total Petroleum hydrocarbons Total Toxic Organics Benchmarks =_=> - - 100 mg/L or 50 mg/L° 6.0 - 9.0 0.007 mg/L 0,033 mg/L. 0.067 mg/L 15 mg/L 1 mg/L 1 07/22/2018 0.11 3.1 mg/L 6.8 0.0079 <0.002 N/A 07/22/201 0.11 8.4 mg/I. 7.0 0.0077 <0.002 0.087 - 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. Z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. ° See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. s Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as fount! in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit D 11/1/2012-10/31/2017 SWU-245, last revise �/25/2012 C Page 1 of 3 �r\ Laboratory Report RR-rcl I V' Environmental Solutions 0810312018 ,..aonaanea,..c Corning Cable Systems Project: Stormwater Client Sample ID: Outfall #1 Attn: Jamie Joines Prism Sample ID: 8070367-01 3180 Centre Park Blvd. Prism Work Order: 8070367 Winston Salem, NC 27107 Sample Matrix: Water Time Collected: 07/22/18 00:28 Time Submitted: 07/25118 08:40 Parameter Result Units Report MDL Dilution Method Analysis Analyst Batch Limit Factor Date/Time ID General Chemistry Parameters Oil 8 Grease (SGT-HEM) BRLOG mg1L 5.0 1.1 1 '1664B 7/26118 9:33 SLS P8G0458 pH 5.7 HT pH Units 1 'SM4600-H B 7/26/18 16:30 COP P8G0460 Total Suspended Solids 3.1 r»gtL 3.1 0.40 1 'SM2540 D 7/26118 13:43 COP PSGO430 Total Metals Copper 7.9 ug1L 6.0 0.22 1 '6020B 811118 17:61 PJF P8130501 Lead BRL ug/L 2,0 0.093 1 `60208 811118 17:51 PJF P8G0501 Zinn 96 ug1L 10 2.8 1 '60208 811118 17:61 PJF P8G0501 This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240643 - Charlotte, NC 28224-0643 Phone: 704/529.6364 - Toll Free Number; 1-8001629-6364 - Fax: 70416254409 Page 3 Of 7 Full -Service Malytic!k PRISM Environmental Solutioo ns ueoawronice r,c Laboratory Report 08/0312018 Corning Cable Systems Project: Stormwater Client Sample lD: Outfall #2 Attn: Jamie Joines Prism Sample ID: 8070367-02 3180 Centre Park Blvd. Prism Work Order: 8070367 Winston Salem, NC 27107 Sample Matrix: Water Time Collected: 07/22/18 00:17 Time Submitted: 07/25/18 08:40 Parameter Result Units Report MDL Dilution Method Analysis Analyst Batch Limit Factor Dateffime ID General Chemistry Parameters Oil 8 Grease (SGT-HEM) BRLOO mg/L 5.0 1.1 1 11664B 7/26/18 9:33 st-S P8G0458 PA 6.6 HT pH Units 1 'SM460044 B 7125118 16:30 CBP PSG0460 Total Suspended Solids 8.4 mg/L 6.0 0.40 1 'SM2640 D 7/25i18 13:43 CSP PSGO430 Total Metals Copper 7.7 ug1L 6.0 0.22 1 16020B VIM 18:18 PJF P8G0601 Lead BRL uglL 2.0 0.093 1 '60208 8/1/18 18:18 PJF P8G0501 Zinc 87 ug1L 10 2.8 1 '6020B 811/18 18:18 PJF PSG0501 This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.Q. Box 240543 • Charlotte, NC 28224-0643 Phone: 7041629-6364 - Toll Free Number: 1.8001529-6364 - Fax: 7041625-0409 Page 4 of 7 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 09/07/2018 CERTIFICATE OF COVERAGE NO. NCG03 0 2 2 7 FACILITY NAME Corning Cable Sys�ir�s` `""' — COUNTY Forsyth PERSON COLLECTING SAMPLES Jamie Joines LABORATORY Test America Lab Cert. # 434 Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2018 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or RrMonthlyl July (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow []Watersupply [:]SA ❑Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ❑ No discharge this period?' Outfall No. Date Sample Collected, (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zlnc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organice Benchmarks ===> - - 100 mg/L or 50 mg/0 6.0 - 9.0 0.007 mg/L 0.033 mg/L 0.067 mg/L 15 mg/L 1 mg/L 1 07/22/2018 0.11 1.7 mg/L 6.8 0.005 <1.3 N/A 07/22/201 0.11 7.9 mg/L 7.0 0.005 0.009 0.068 < . k Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the saine parameter at the same outfall. z For sampling periods with no discharge at any single outfail, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469,22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31), Permit Dt' 11/1/2012-10/31/2017 5WU-245, last revise" ,r25/2012 Page 1 of 3 Lab Chronicle Client: Michael Baker International, Inc. TestAmerica Job ID: 180-80122-1 Project/Site: Stormwater, Winston Salem, NC Client Sample ID: OUTFALL 01 Lab Sample ID: 180-80122-1 Date Collected: 07122/18 12:28 Matrix: Water Date Received: 07/25/18 09:00 Batch Batch Prop Type Type Method Run Total Recoverable Prep 3005A Total Recoverable Analysis EPA 6020B Instrument ID: M Total/NA Prep 1664E Total/NA Analysis 1664E Instrument ID: NOEQUIP Total/NA Analysis SM 2540D Instrument ID: NOEQUIP Total/NA Analysis SM 4500 H+ B Instrument ID: NOEQUIP Dil Initial Final Batch Prepared Factor Amount Amount Number or Analyzed Analyst Lab 50 mL 50 mL 251787 07/26/18 13:37 KA TAL PIT 1 252524 07/31/18 22A9 WTR TAL PIT 1003 mL 960 mL 533397 08/02/18 13:17 BAD TAL NSH 1 533454 08102/18 13:17 BAD TAL NSH 1 1000 mL 1000 mL 251757 07/26/18 12:07 RMA TAL PIT 1 251699 07/26/18 08:22 CRM TAL PIT Client Sample ID: OUTFALL 02 Lab Sample ID: 180-80122-2 Date Collected: 07/22/18 12:17 Matrix: Water Date Received: 07/25/18 09:00 Batch Batch DI1 Initial Final Batch Prepared Prep Type Type Method Run Factor Amount Amount Number or Analyzed Analyst Lab Total Recoverable Prep 3005A 50 mL 50 mL 25 7787 07126/18 13:37 KA TAL PIT Total Recoverable Analysis EPA 6020B 1 252524 07/31/18 22:54 WTR TAL PIT Instrument ID: M TotatlNA Prep 1664E 995 mL 960 mL 533397 08102/18 13:17 BAD TAL NSH Total/NA Analysis 1664B 1 533454 08/02/18 13A 7 BAD TAL NSH Instrument ID: NOEQUIP TotalINA Analysis SM 2540D 1 1000 mL 1000 mL 251757 07/26/18 12:07 RMA TAL PIT Instrument ID: NOEQUIP TotaI1NA Analysis SIVI 4500 H+ B 1 251699 07/26118 08:22 CRM TAL PIT Instrument ID: NOEQUIP Laboratory References: TAL NSH = TestAmerica Nashville, 2960 Foster Creighton Drive. Nashville, TN 37204, TEL (615)726-0177 TAL PIT = TestAmerica Pittsburgh, 301 Alpha Drive, RIDC Park, Pittsburgh, PA 15238, TEL (412)963-7058 Page 8 of 21 TestAmerica Pittsburgh 8/3/2018 AUGUST 2018 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Resources General Permit No. NCG030000 Date submitted September 10, 2018 CERTIFICATE OF COVERAGE NO. NCG03__T _� v Q �7 SAMPLE COLLECTION YEAR 2018 FACILITY NAME Coming Cable Systems SAMPLE PERIOD ❑ Jan -June ❑ July -Dec COUNTY FOrsvfh— or X Monthly' August 2018 (month) PERSON COLLECTING SAMPLES NIA LABORATORY N/A Lab Cert. # Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results RE H V MUSCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA SEP 2 4 2018 []Zero -flow ❑Water Supply ❑SA ❑Other : �EP,4*kAL. FILES bW EGTf0N PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 ■❑ No discharge this period?' Outfall No. Date Sample n Collected (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organics 5 Benchmarks ===> - - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall 1 No Flow Outfall 2 No Flow 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-30/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 SEPTEMBER 2018 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Resources General Permit No. NCG030000 Date submitted 1012412018 CERTIFICATE OF COVERAGE NO. N00030227 FACILITY NAME Coming Cable Systems, LLC COUNTY Forsvth PERSON COLLECTING SAMPLES Darren Swart LABORATORY TestAmerica Laboratories, Inc. Lab Cert. tt 434 Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2018 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ❑■ Monthly' September (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flaw ❑Water Supply ❑SA ❑Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 No discharge this period?2 OutfaU No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, inches Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar 0&G/ Total Petroleum Hydrocarbons Total Toxic Organics' Benchmarks -_-> _ - 100 mg/L or 50 mg/L4 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L 1 09/09/2018 2.27 7.8 7.5 0.0023 0.001 0.038 <3.7 2 09/09/2018 2.27 3.1 7.7 0.0021 <0.001 0.049 <3.7 ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433,11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 5WU-245, last revised 10/25/2012 Page 1 of 3 Client Sample Results Client: Michael Baker International, Inc. Project/Site: Stormwater, Winston Salem, NC Client Sample ID: OUTFALL 01 Date Collected: 09/09/18 03:23 Date Received: 09/11/18 10:00 TestAmerica Job ID: 180-81754-1 Lab Sample ID: 180-81754-1 Matrix: Water Method: EPA 6020E - Metals (ICPIMS) - Total Recoverable i Analyte Result Qualifier RL MOIL UnCt D Prepared Analyzed Dil Fac J Copper 2.3 2.0 1.3 ug1L 09/12/1812:17 09119/1815:23 1 Lead 1.0 1.0 0.094 ug1L 09/12/18 1217 09119/18 15:23 1 zinc 38 5.0 2.4 ug1L 09/12/1812:17 09119/1815:23 1 General Chemistry Analyte Result Qualifier RL MOIL Unit D Prepared Analyzed Oil Fac HEM ND 3.7 1.3 mg/L 09/29118 14:37 09/29/18 16:25 1 L SGT-HEM ND 3.7 1.3 mg/L 09/2911814:37 09/2911816:25 "a Total Suspended Solids 7.8 0.50 0.50 mg/L 09112/18 09:20 1 Analyte Result Qualifier RL RL Unit D Prepared Analyzed Oil Fac pH 6.5 HF 0.1 0.1 SU 09/12/18 08:48 1 Client Sample ID: QUTFALL 02 Lab Sample ID: 180-81754-2 Date Collected: 09/09/13 03:47 Matrix: Water Date Received: 09111/18 10:00 Method: EPA 6020B - Metals (ICPIMS) - Total Recoverable I<;,., Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Oil Fac Copper 2.1 2.0 1.3 ug/L 0911211812:17 09/1911815:26 1 Lead 0.35 J 1.0 0.094 ug/L 09112/1612:17 09/1911815:26 1 Zinc 49 5.0 2.4 ug1L 09112/1812:17 09/1911815:26 1 General Chemistry Analyte SGT-HEM Total Suspended Solids Analyte pH Result Qualifier RL MOIL Unit D Prepared Analyzed Dil Fac NO 3.7 1.3 mg/L 09129/1814:37 0912911816:25 1 ND 3.7 1.3 mg1L 09/2911814:37 09/2911816:25 1 3.1 0.50 0.50 mg1L 09112/18 09:20 1 Result Qualifier RL RL Unit D Prepared 7.0 HF 0.1 0.1 SU Analyzed Oil Fac 09112118 08:48 1 TestAmerica Pittsburgh Page 10 of 18 10/1/2018 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Resources General Permit No. NCG030000 Date submitted 10124/2018 CERTIFICATE OF COVERAGE No. N00030227 FACILITY NAME Corning Cable Systems, LLC COUNTY Forsyth PERSON COLLECTING SAMPLES Darren Swart LABORATORY Prism Laboratories, Inc. Lab Cert. d 402 Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2018 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or © Monthly' September (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA []Zero -flow ❑Water Supply [:]SA ❑Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 -) ❑ No discharge this period?2 Outfall No. Date Sample p Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids p H, Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organitss Benchmarks =_-> - - 100 mg/L or 50 mg/L° 6.0 - 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L i mg/L 1 09/09/2018 2.27 8.2 7.5 <0,005 <0.001 <0.065 <0.005 2 09/09/2018 2.27 3.2 7.7 0.013 0.006 <0.065 <0.005 2 (re -run) 09/09/2018 2.27 NIA N/A <0.005 NIA N/A N/A 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. Z For sampling periods with no discharge at any single out#all, you must still submit this discharge monitoring report with a checkmark here. 3 The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. ° See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469,31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Laboratory Report c - i FuILServlcs Analytical 8 r I EilvIrOnmental Solutions 10/1712018 "Yi.eonros�ax We Corning Cable Systems Project: Stormwater Client Sample ID: Outfall ##1 Attn: Jamie Joines Prism Sample ID: 8090133-01 3180 Centre Park Blvd. Prism Work Order: 8090133 Winston Salem, NC 27107 Sample Matrix: Water Time Collected: 09/09/18 03:23 Time Submitted: 09/12/18 08:00 Parameter Result Units Report MDL Dilution Method Analysis Analyst Batch Limit Factor DatelTime ID General Chemistry Parameters od & Grease (SGT-HEM) BRL©C, mg& 5.0 1.1 1 '1664B 9/13118 9:24 SLS P810223 pH 6.5 HT pH Units 1 'SM4500-H B 9112118 16:46 CBP P810178 Total Suspended Solids 8.2 mg1L 2.6 0.40 1 'SM2540 D 9113118 14.54 CBP P810202 Total Metals Copper BRL uglL 5.0 0.22 1 '6020B 9/21118 1 T.24 JAB P610229 Lead BRL ug1L 1.0 0.093 1 '6020B 9121118 17:24 JAB P810229 Zinc BRL ug1L 65 2.8 1 '6020B 9/21116 17:24 JAB P810229 This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0643 Phone: 7041629.6364 - Tall Free Number: 1.8001529-6364 - Fax: 7041525-0409 Page 3O Laboratory Report Apzs!R; Full-5ervlce Analytical 6 i q m IEnvironmental Solutions 10117/2016 ,..eQn.,ow�ra..c Corning Cable Systems Project: Stormwater Client Sample ID: Outfall #2 Attn: Jamie Joines Prism Sample ID: 8090133-02 3180 Centre Park Blvd. Prism Work Order: 8090133 Winston Salem, NC 27107 Sample Matrix: Water Time Collected: 09/09/18 03:47 Time Submitted: 09112/18 08:00 Parameter Result Units Report MDL Dilution Method Analysis Analyst Batch Limit Factor DateTrime I❑ General Chemistry Parameters Oil & Grease (SGT-HEM) BRLOC mglL 5.0 1.1 1 '1664B 9/18/18 9:40 SLS P810266 pH 6.3 HT pH Units 1 'SM4500-H B 9112118 16:46 CUP P810178 Total Suspended Solids 3.2 m911- 2.9 0.40 1 'SM2540 D 9113118 14:64 CUP P810202 Total Metals Copper 13 uglL 6.0 0.22 1 '6020B 9121118 17:52 JAB P810229 Lead 6.0 uglL 1.0 0.093 1 '6020B 9/21/18 17:52 JAB P810229 Zinc BRL ug/L 65 2.8 1 '6020B 9/21/18 17:52 JAB P810229 This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240643 - Charlotte, NC 28224-0643 Phone: 70416294364 - Toll Free Number: 1.8001629-6364 - Fax: 704152"409 Page 4 of 8 Laboratory Report do 8Envlrenmgnfgl isin IFunironm �)(v�aoR�.nmF9, 1C1(1712t)18 Solutions n al Sol n Corning Cable Systems Project: Stormwater Client Sample ID: Outfall #2 Attn: Jamie Joines Prism Sample ID: 8090133-02RE1 3180 Centre Park Blvd. Prism Work Order: 8090133 Winston Salem, N IC 27107 Sample Matrix: Water Time Collected: 09/09/18 03:47 Time Submitted: 09112118 0&00 Parameter Result Units Report MDL Dilution Method Analysis Ana"t Batch Limit Factor Date/Time ID Total Metals Copper BRL ug1L 5.0 0,22 t •60206 10115/18 21:48 JAB PBJ0184 This report should not be reproduced, except in its entirety, without the written consent of Prism Laboratories, Inc. 449 Springbrook Road - P.O. Box 240543 - Charlotte, NC 28224-0543 Phone: 7041629.6364 -Toll Free Number: 1-800/629-6364 - Fax: 7041626-0409 Page 5 of 8 OCTOBER 2018 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Resources General Permit No. NCG030000 Date submitted 12r0412018 CERTIFICATE OF COVERAGE No. NCG030227 FACILITY NAME Coming Optical Communications, LLC COUNTY ForsVth PERSON COLLECTING SAMPLES Jamie Joines LABORATORY TestAmenra Laboratories, Inc. Lab Cert. # 434 Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results ��AN 5AMPLE P®RIOD I❑JanAJune'B❑luly-Dec 'ECE DEC 12 201 or 0 Monthly'October (month) D SCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA CENTRAL FILES ❑Zero -flow ❑Water Supply ❑SA DWR SECTION ❑Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ❑ No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/� .Total Total Petroleum Hydrocarbons Toxic ,Organics Benchmarks _ - 100 mg/L or 50 mg/0 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L 1 10/26/2018 2.32 8.0 6.8 0,0022 <0.001 0.029 <3.9 NIA 2 10/26/2018 2.32 24 7.6 0.0046 0.0019 0.100 <3.9 NIA ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. ° See General Permit., Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. s Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Client Sample Results ; Client: Corning bptical Communications LLC TestAmerica Job ID: 180-83506-1 Project/Site: Corning OpticalStormwater, Winston Salem Client Sample ID: ®UTFALL 1 Lab Sample ID: 180-83506-1 Date Collected: 10/26/18 08:46 Matrix: Water Date Received: 10/30/18 09:00 Method: EPA 6020E - Metals (ICP/MS) - Total Recoverable Analyte Result Qualifier RL MDL Unit Copper 2.2 2.0 1.3 ug1L Lead 0.77 J 1.0 0.094 ug1L Zinc 29 5.0 2.4 ug1L General Chemistry D Prepared Analyzed DII Fac I 10/31118 12:15 11/01/18 12:29 1 10/31118 12:15 11101/18 12:29 1 10/31118 12:15 11/01/18 12:29 1 Analyte Result Qualifier RL MDL Unit D Prepared Analyzed DII Fac = 4c1 HEM ND 3.9 1.4 mg1L 1111311811:41 11113/1811:41 1 SGT-HEM ND 3.9 1.4 mg/L 11113MB 11:41 11113/18 11:41 1 Total Suspended Solids 8.0 0.50 0.50 mg/L 10130118 14:14 1 Analyte Result Qualifier RL RL Unit D Prepared Analyzed Dii Fac pH 7.0 HIP 0.1 0.1 SU — 11/06/1809:49 1 TestAmerica Pittsburgh Page 9 of 17 11/14/2018 Client Sample Results Client: Corning Optical Communications LLC Project/SiW Corning OpticalStorrnwater, Winston Salem F, i TestAmerica Job ID: 180-83477-1 C 1, Client Sample ID: OUTFALL 02 Lab Sample ID: 180-83477-1 Date Collected: 10/26118 08:35 Matrix: Water Date Received: 10/29/18 08:15 Method: EPA 6020B - Metals (ICPIMS) - Total Recoverable i Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac { Copper 4.6 2.0 1.3 ug/L 10/30118 12:15 10/31/18 22:44 1 Lead 1.9 1.0 0.094 ug1L 10130118 12:15 10/31/18 22:44 1 Zinc 100 5.0 2.4 ug/L 10130118 12:15 10131/18 22:44 1 General Chemistry Analyte Result Qualifier RL MDL Unit D Prepared Analyzed DII Fac i E1 HEM ND 3.9 1.4 mg/L 1111311811:41 11/13/18 11:41 1 c = s SGT-HEM ND 3.9 1.4 mg/L 1111311811:41 11113/1811:41 1 Total Suspended Solids 24 0.77 0.77 mg1L 10130118 14:14 1 Analyte Result Qualifier RL RL Unit D Prepared Analyzed Dii Fac pH 7.5 HF 0.1 0_1 SU 10130/1810:54 1 TestAmerica Pittsburgh Page 9 of 17 11/14/2018 NOVEMBER 2018 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Resources General Permit No. NCG030000 CERTIFICATE OF COVERAGE No. NCG030227 FACILITY NAME Corning Optical Communications, LLC COUNTY Forsyth PERSON COLLECTING SAMPLES Jamie Joines Date submitted 12ro412018 RECEIVED FFB 18 2019 LABORATORY TestAmerica Laboratories, Inc. Lab Cert. f# 434 t r--N T ►SAL FILES Comments on sample collection or analysis: 1: WR SECTION Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2018 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or X Monthly' November month DISCHARGING TO CLASS ❑ORW ❑HQW []Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA ❑Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 No discharge this period?2 outfall No. Daze Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids' pH, Standard units Copper Lead Zinc Non -Polar 0&G/Total Total Petroleum Hydrocarbons Toxic Organics Benchmarks =__> - - 100 mg/L or 50 mg/O 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L 1 11 /24/2018 0.53 8.2 8.3 0.0022 <0.001 0.030 <4.0 N/A 2 11/24/2018 0.53 4.0 8.1 0.0038 <0.001 0.040 <3.9 NIA ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. Z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. " See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Client Sample Results Client: Corning Optical Communications LLC Project/Site: Corning OpticalStormwater, Winston Salem Client Sample ID: OU TFALL 1 Date Collected: 11/24/18 07:00 Date Received: 11/27118 12:30 Method: EPA 6020B - Metals (ICP/MS) - Total Recoverable Analyte Result Qualifier RL MDL Unit Copper 2.2 2.0 1.3 ug/L Lead 0.81 J 1.0 0.094 ug/L Zinc 30 5.0 2A ug/L General Chemistry Analyte Result Qualifier HEM ND SGT-HEM ND Total Suspended Solids 8.2 Analyte Result Qualifier pH 6,1 TestAmerica .Gab ID: 180-84300-1 Lab Sample ID: 180-84300-1 Matrix: Water D Prepared Analyzed Dil Fac 11 /29/18 11:39 11 /30/18 09:52 1 11/29/18 11:39 11/30/18 09:52 1 11/29/18 11:39 11/30/18 09:52 1 RL MDL Unit D Prepared 1210311814:04 Analyzed 12/0311814:04 Dil Fac 1 4.0 1.4 mg/L 4.0 1.4 mg/L 12/03/1814:04 12/0311814:04 1 0.50 0.50 mgtL 11/27/1814:53 1 RL RL Unit D Prepared Analyzed Dil Fac 0.1 0.1 SU _ 11/2811806:10 1 Client Sample ID: OUT FALL 2 Lab Sample ID: 180-84300-2 Date Collected: 11/24/18 07:10 Matrix: Water Date Received: 11/27118 12:30 Method: EPA 6020B - Metals (ICPIMS) - Total Recoverable Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac Copper 3.8 2.0 1.3 ug/L 11/29118 11:39 11130/18 09755 1 Lead 0.60 J 1.0 0.094 ug/L 11129118 11:39 11130/18 09:55 1 Zinc 40 5.0 2.4 ug/L 11/29118 11:39 11130/18 09:55 1 General Chemistry Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac HEM ND 3.9 1.4 mg/L W 12103/1814:04 12103/1814:04 1 SGT-HEM NO 3.9 1.4 mg/L 1210311814:04 12103/1814:04 1 Total Suspended Solids 4.0 0.50 0.50 mglL 11127/18 14:53 1 Analyte Result Qualifier RL RL Unit D Prepared Analyzed Dil Fac pH 6.9 0.1 0.1 SU Ti 08:10 1 TestAmerica Pittsburgh Page 9 of 17 12/11 /201 8 DECEMBER 2018 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Resources General Permit No. NCG030000 Date submitted 02/01/2019 CERTIFICATE OF COVERAGE NO. NCG030227 SAMPLE COLLECTION YEAR 2018 FACILITY NAME Corning optical Communications, LLC 6MPLI PERIOD ❑ Jan -June ❑ July -Dec COUNTY FOrsyfh- RECEIVE or ❑■ Monthlyl December 201s (month) PERSON COLLECTING SAMPLES Jamie Joines DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA TestAmerica Laboratories, Inc. 434 FEB 12 2019 ❑Zero -flow ❑Water Supply []SA LABORATORY Lab Cert. # Comments on sample collection or analysis: CENTRAL FILES [:]Other DWR SECTION Part A: Stormwater Benchmarks and Monitoring Results PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 No discharge this period?' Outfall No. Date Sample Collected) (mo/dd/yr) 24-hour rainfall amount, Inches" Total Suspended Solids pH, standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics5 Benchmarks =__> _ - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L 1 12/14/2018 0.36 19 7.0 0.018 0.0033 0.068 <3.9 NIA 2 12/14/2018 0.36 57 7.4 0.017 0.0059 0.180 <3.9 NIA 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. s Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Client Sample Results Client: Corning Optical Communications LLC TestAmerica Job ID: 180-85008-1 ProjectlSite: Coming OpticalStormwater, Winston Salem f Client Sample ID: OUTFALL 01 Lab Sample ID: 180-85008-1 Date Collected: 12/14/18 14:32 Matrix: Water bate Received: 12/18/18 10:15 Method: EPA 6020B - Metals (ICP/MS) - Total Recoverable Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac Copper 18 2.0 1.3 ug1L 12/2111812:20 12/26/1809:51 1 Lead 3.3 1.0 0.094 ug1L 12/21/18 12:20 12/26/18 09:51 1 Zinc 68 5.0 2.4 ug1L 12/21/18 12:20 12/26/18 09:51 1 General Chemistry Analyte Result Qualifier RL HEM 2.1 J 3.9 SOT -HEM 2.1 J 3.9 Total Suspended Solids 19 0.50 MDL Unit 1.4 mgll. 1.4 mg/L 0.50 mg1L D Prepared Analyzed Dil Fac 12/27118 16:09 12/27/18 17:30 1 12/27118 16:09 12/27/18 17:30 1211911808:46 1 Analyte Result Qualifier RL RL Unit D Prepared Analyzed Dil Fac pH 6.7 HF 0,1 0.1 SU 12119/1813:07 1 Client Sample ID: OUTFALL 02 Lab Sample ID: 180-85008-2 Date Collected: 12/14/18 14:46 Matrix: Water Date Received: 12/18/18 10:15 FMethod: EPA 6020B - Metals (ICP1MS) - Total Recoverable i Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac Copper 17 2.0 1.3 ug1L 12/21118 12:20 12/26/18 09:54 1 Lead 6.9 1.0 0.094 ug/L 12121/18 1210 12/26/18 09:54 1 zinc 180 5.0 2.4 ug/L 1212111812:20 12/26/18 09:54 1 General Chemistry Analyte Result Qualifier RL HEM ND 3.9 SGT-HEM ND 3.9 Total Suspended Solids 57 1.3 Analyte Result Qualifier RL pH 6.9 HF 0.1 MDL Unit D Prepared Analyzed Dil Fac 1.4 mg1L 12127/1816:09 1212711817:30 1 1.4 mg1L 1212711816:09 1212711817;30 1 1.3 mg1L 12119/18 08:46 1 RL Unit D Prepared Analyzed oil Fac 0.1 SU 121194181107 1 TestAmerica Pittsburgh Page 10 of 18 1/3/2019 JANUARY 2019 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Resources General Permit No. NCG030000 Date submitted 02/2112019 CERTIFICATE OF COVERAGE NO. NCG030227 FACILITY NAME Coming Optical Communications, LLC COUNTY Forsvth PERSON COLLECTING SAMPLES Jamie Jo+nes RECEIVEn. LABORATORY TestAmerica Laboratories, Inc. Lab Cert. # 434 Comments on sample collection or analysis: FEB 2 S Z019 - -- ---- gNTRAL FILES DWR SECTION Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2019 SAMPLE PERIOD ❑ Jan -June ❑ Judy -Dec or Monthly' January 2019 (month) DISCHARGING TO CLASS ❑ORW ❑HQW [—]Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA ❑Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 --) No discharge this period?' Outfall No. Date Sample , Collected (mo/dd/yr) 24-hour rainfall amount, lnches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar 0&G/ Total Petroleum Hydrocarbons Total Toxic s Organics Benchmarks - - 100 mg/L or 50 mg/1.4 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L 1 01/14/2018 1.02 6.3 6.9 0.0036 <0.001 0.025 <3.9 N/A 2 01 /14/2018 1.02 5.0 7.4 0.0032 <0.001 0.030 <3.9 N/A 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfail. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. s Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-30/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Client Sample Results Client: Corning Optical Communications LLC Project/Site: Corning OpticalStormwater, Winston Salem Client Sample ID: OUTFALL 01 Date Collected: 01/24119 08:45 Date Received: 01/25/19 09.45 Method: EPA 6020E - Metals (ICPiMS) - Total Recoverable Ana" Result Qualifier RL Copper 3.6 2.0 Lead 0.92 J B 1.0 Zinc 25 5.0 General Chemistry AnaWe Result Qualifier RL HEM ND 3.9 SGT-HEM ND 3.9 Total Suspended Solids 6.3 0.50 Analyte Result Qualifier RL PH 6.9 HF 0.1 Client Sample ID: OUTFALL 02 Date Collected: 01/24/19 08:50 Date Received: 01/25/19 09:45 TestAmerica Job ID: 180-86100-1 Lab Sample ID: 180-86100-1 Matrix: Water MDL Unit D Prepared Analyzed Oil Fac " 1.3 ug/L 01/2911911:24 011301191T41 1 0.094 ug/L 01/2911911:24 01/30/1917:41 1 2A ug1L 01/2911911:24 01/3011917:41 1 MDL Unit D Prepared Analyzed 1.4 mg/L 0210411913:45 0210411913:45 1.4 mglL 02104/1913:45 02104/1913:45 0.50 mg1L 01/26/19 09:15 RL Unit D Prepared Analyzed 0.1 SU _ 01129/1912:37 Oil Fac 1 1 n 1 Oil Fac Lab Sample ID: 180-86100-2 Matrix: Water Method: EPA 6020B - Metals (ICPIMS) -'total Recoverable Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Oil Fac Copper 3.2 2.0 1.3 ug/L 01/2911911:24 01/30/1917:45 1 Lead 0.75 J B 1.0 0.094 ug/L. 01/29/19 11:24 01/30/19 17:45 1 Zinc 30 5.0 2.4 ug/L 0112911911:24 01/3011917:45 1 General Chemistry Analyze Result Qualifier RL MOIL Unit D Prepared Analyzed Oil Fac HEM ND 3.9 1.4 mg1L 02104M913:45 0210411913:45 1 SCT-HEM ND 3.9 1.4 mg/L 02104/1913:45 02104/1913:45 1 Total Suspended Solids 5.0 0.50 0.50 mg/L 01/26119 09:15 1 Analyte Result Qualifier RL RL Unit D Prepared Analyzed Dil Fac PH 7.3 HF 0.1 0.1 SU 01129119 12:37 1 TestAmerica Pittsburgh Page 10 of 18 2/5/2019 FEBRUARY 2019 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Resources General Permit No. NCG030000 Date submitted March 15, 2019 CERTIFICATE OF COVERAGE NO. NCG03 0 2 2 7 FACILITY NAME Coming Cable Systems COUNTY Forsyth PERSON COLLECTING SAMPLES N/A Q E 1� � LABORATORY NIA Lab Cert. # Comments on sample collection or analysis: MAR 2 0 2019 �-tN) RAL FILES DV�R SECTION Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2019 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or Monthly' February 2019 (monthl DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA []Zero -flow []WaterSupply ❑SA ❑Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 --> ❑0 No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, lnches3 Total Suspended Solids PH, Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organicss Benchmarks =__> _ 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L Outfall 1 No Flow Outfall 2 No Flow 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. `See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. s Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 MARCH 2O19 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Resources General Permit No. NCG030000 Date submitted 04/0512019 CERTIFICATE OF COVERAGE NO. NCG030227 FACILITY NAME Coming Optical Communications, LLC COUNTY Forsyth PERSON COLLECTING SAMPLES Jamie Joines n ir— t-r.—1 E D LABORATORY TestArnerica Laboratories, Inc. Lab Cert. # 434 1 Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results APR 15 2019 SAMPLE COLLECTION YEAR 2019 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or *Monthly' March 2019 _(monk © DIS' E SCHAR GIINiG 10 CLASS ❑ORW ❑HQW [:]Trout ❑PNA r� ❑Zero -flow [:]WaterSupply ❑SA APR -ft 2019 ❑other ;t_-N 13IAL FILES CENTIRAL P1 et -EASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 [ANR SECTION tab^1R S-'7-Tl01%, No dischorge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organicss Benchmarks =_=> - - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L 1 03/01/2019 0.18 18 6.8 0.005 0.002 0.062 <3.6 NIA 2 03/01/2019 0.18 2.7 7.3 0.002 <0.001 0.048 <3.6 NIA ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. Z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 5WU-245, last revised 10/25/2012 Page 1 of 3 Client Sample Results Client: Corning Optical Communications LLC TestAmerica Job ID: 180-87228-1 Project/Site: Corning OpticalStormwater, Winston Salem Client Sample ID: OUTFALL 1 Lab Sample ID: 180-87228-1 Date Collected: 03/01119 08:15 Matrix: Water Date Received: 03/02/19 10:00 Method: EPA 6020B - Metals (ICP/MS) - Total Recoverable Analyte Result Qualifier RL MDL Unit D Prepared Analyzed rFF I� Dil Fac �1 1 Copper 5.4 B 2.0 0.63 ug/L 03105/1911:50 0310811913:17 1 Lead 1.5 1.0 0.13 uglL 03/0511911:50 0310811913:17 1 Zinc 62 5.0 3.2 uglL 03105119 11:50 03108/1913:17 1 General Chemistry Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac HEM ND 3.6 1.3 mg/L 03/1311912:18 0311311912:18 1 SGT-HEM ND 3.6 1.3 mg/L 03/13/1912:18 03/1311912:18 1 Total Suspended Solids 18 0.50 0.50 mg/L 03/05/19 08:37 1 Analyte Result Qualifier RL RL Unit D Prepared Analyzed Dil Fac pH 6.7 HF 0.1 0.1 SU 0311311914:39 1 Client Sample ID: OUTFALL 2 Lab Sample ID: 180-87228-2 Date Collected: 03/01/19 08:20 Matrix: Water Date Received: 03/02/19 10:00 Method: EPA 6020E - Metals (ICP/MS) - Total Recoverable .:. Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac Copper 2.3 B 2.0 0.63 5g/L 0310511911:50 0310811913:21 1 Lead 0.49 J 1.0 0.13 ug/L 03/05/1911:50 0310811913:21 1 Zinc 48 5.0 3.2 ug/L 03105/1911:50 0310811913:21 1 General Chemistry Analyte SGT-HEM Total Suspended Solids Analyte PH Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac ND 3.6 1.3 mg/L 031131191215 0311311912:18 1 ND 3.6 1.3 mg/L 0311311912:18 03113/1912:18 1 2.7 0.50 0.50 mg/L 03/05/19 08:37 1 Result Qualifier RL RL Unit D Prepared Analyzed Dil Fac 7.3 HF 0.1 0.1 SU 03/13/1914:39 1 TestAmerica Pittsburgh Page 10 of 18 3/19/2019 APRIL 2019 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Resources General Permit No. NCG030000 Date submitted 05/2W2019 CERTIFICATE OF COVERAGE NO. N00030227 FACILITY NAME 'Corning Optical Communications. LLC COUNTY Forsyth PERSON COLLECTING SAMPLES Jamie Joines LABORATORY TestAmerica Laboratories, Inc. Lab Cert. # 434 Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2019 SAMPLE PERIOD ❑ Jan -June ❑ July-Dec � , or ❑■ Monthly1ApOl2019 —[month) RECEIVE DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA —MAY 31 2019 ❑Zero -flow ❑Water Supply ❑SA ❑Other CENTRAL FILES --«l"JiR SI"CTION PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 n No discharge this period ?� N ' . •Outfall No..'• ` _- Gate. Sample -• - : Collected (mo/dd/yr) I 24=hour rainfall amount, Inches; Total Suspended Solids pH, Standard units Copper - • Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic s Organics Benchmorks _> _ - 100 mg/L or 50 mg/0 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L 1 04/05/2019 0.81 2.9 7.2 0.0023 [0.001 0.033 <3.6 NIA 2 04/05/2019 0.81 24 6.8 0.0046 0.002 0.059 <3.6 NIA 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. a See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. s Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469,12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Client Sample Results Client° Corning Optical Communications LLC Job ID: 180-88653-1 Project/Site: Corning OpticalStormwater, Winston Salem Client Sample ID: OUTFALL 1 Lab Sample ID: 180-88653-1 Date Collected: 04/05119 08:10 Matrix: Water Date Received: 04/06/19 09:15 Method: EPA 6020D - Metals (ICP/MS) - Total Recoverable Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac Copper 2.3 2-0 0.63 ug/L 0410811911:53 04113/1913:01 1 Lead 0.42 J 1.0 0.13 ug/L 0410811911:53 04113/1913:01 1 Zinc 33 5.0 3.2 uglL 04i0811911:53 04113/1913:01 1 General Chemistry Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac HEM ND 3.6 1.3 mg1L 04122/1912:09 04122/1912:09 1 SGT-HEM ND 3.6 1.3 mg1L 04122/1912:09 04122/1912:09 1 Total Suspended Solids 2.9 0.50 0.50 mg/L 04109/19 09:29 1 Analyte Result Qualifier RL RL Unit D Prepared Analyzed Dil Fan pH 7.1 HF 0.1 0.1 SU 04J11119 t2:59 1 Client Sample ID: OUTFALL 2 Date Collected: 04/05/19 08:15 Date Received: 04/06/19 09:15 Lab Sample ID: 180-88653-2 Matrix: Water Method: EPA 6020E - Metals (ICPIMS) - Total Recoverable Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac Copper 4.6 2.0 0.63 ug1L 04/0811911:53 (1411311913:05 1 Lead 2.0 1.0 0.13 ug/L 04/08/1911:53 04/1311913:05 1 Zinc 59 5.0 3.2 ug1L 0410811911!53 0411311913:05 1 General Chemistry Analyte Result Qualifier RL MDL Unit D Prepared Analyzed oil Fac HEM ND 3.6 1.3 mg/L 0412211912:09 04122/1912:09 1 SGT-HEM ND 3.6 1.3 mg/L 04122/1912:09 04122/1912:09 1 Total Suspended Solids 24 1.0 1.0 mg1L 04/09/19 09:29 1 Analyte Result Qualifier RL RL Unit D Prepared Analyzed Dil Fac pH 6.8 NF 0.1 0.1 SU 04111/1 112.59 1 Eurofins `iestAmerica, Pittsburgh Page 9 of 17 4/23/2019 MAY 2019 Stormwater Discharge Monitoring Report for North Carolina Division of Energy, Mineral and Land Resources General Permit No. NCG030000 Date submitted 0710312019 CERTIFICATE OF COVERAGE NO. N0003 0 2 2 7 FACILITY NAME Coming Optical Communications, LLC COUNTY Forsyth PERSON COLLECTING SAMPLES Jamie Joines D m r, F: 1\ 11= LABORATORY TestAmerica Laboratories, Inc. Lab Cert. # 434 ' Comments on sample collection or analysis: JUL 12 2019 I i;iiL FILES DOOM CI=CTION Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2019 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or Q Monthly' May Lm ont'h1 DISCHARGING TO CLASS ❑ORW ❑HCIW []Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA ❑Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ❑ No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches-' Total Suspended Solids pH, Standard units Total Copper Total Lead Total Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organics5 Benchmarks _ - 100 mg/L or 50 mg/L4 6.0 — 9.0 0.010 mg/L 0.075 mg/L 0.126 mg/L 15 mg/L 1 mg/L Parameter Code - 46529 C0530 00400 01119 01051 01094 00552 78141 1 05/23/2019 0.42 22 6.8 0.0038 <0.001 0.048 <1.4 NIA 2 05/23/2019 0.42 35 7.3 0.009 0.0016 0.081 <1.4 NIA ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 'The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Section B, Table 1 to identify the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/l/2018-05/31/2021 SWU-245, last revised 11/1/2018 Page 1 of 3 Client Sample Results Client: Corning Optical Communications LLC Project/Site: Corning OpticalStormwater, Winston Salem Client Sample ID: OUTFALL 1 Date Collected: 05123/19 08:50 Date Received: 05/24/19 08:00 Method: EPA 6020B - Metals (ICPIMS) - Total Recoverable Analyte Result Qualifier RL Copper 3.8 2.0 Lead 0.63 J 1.0 Zinc 48 5.0 General Chemistry Analyto SGT-HEM Total Suspended Solids Analyte PH Job ID: 180-90504-1 Lab Sample ID: 180-90504-1 Matrix: Water MDL Unit D Prepared Analyzed 0.63 uglL 05/30/19 14:34 06/01/19 19:37 0.13 uglL 0513011914:34 06/0111919:37 3.2 uglL 05130/1914:34 06/0111919:37 Result Qualifier RL MDL Unit D Prepared Analyzed DII Fac ND 3.9 1.4 mglL 06107/1912:25 06/07/1912:25 1 � ND 3.9 1.4 mglL 0610711912:25 0610711912:25 1 22 0.50 0.50 mglL 05/25/19 08:49 1 Result Qualifier RL RL Unit D Prepared Analyzed Dil Fac 6.8 HF 0.1 0.1 SU 05129/1914:16 1 Client Sample ID: OUTFALL 2 Lab Sample ID: 180-90504-2 Date Collected: 05/23119 08:45 Matrix: Water Date Received: 05/24/19 08:00 Method: EPA 6020B - Metals (ICPIMS) - Total Recoverable Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac! Copper 9.0 2.0 0.63 ug1L 05/3011914:34 06101/1919:42 1 Lead 1.6 1.0 0.13 uglL 05130/1914:34 0610111919A2 1 Zinc . 81 5.0 3.2 uglL 05/30/19 14:34 06/01/19 19A2 1 General Chemistry Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac HEM ND 3.9 1.4 mg1L 06/0711912:25 06/07/1912:25 1 SGT-HEM ND 3.9 1.4 mglL 06107/1912:25 06/07/1912:25 1 Total Suspended Solids 35 0.83 0.83 mg1L 05/25/19 08:49 1 Analyte Result Qualifier RL RL Unit D Prepared Analyzed Dil Fac PH 7.3 HF 0.1 0.1 SU 05129/1914:18 1 Eurofins TestAmerica, Pittsburgh Page 9 of 14 6/10/2019 JUKE 2019 Stormwater Discharge Monitoring Report for North Carolina Division of Energy, Mineral and Land Resources General Permit No. NCG030000 Date submitted 0712912019 CERTIFICATE OF COVERAGE NO. NCG03 o 2 2 7 FACILITY NAME Coming Optical Communications, LLC COUNTY Forsyth PERSON COLLECTING SAMPLES Jamie Joines LABORATORY TestAmerica Laboratories, Inc. Lab Cert. # 434 Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2019 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or Q Monthly' June (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA RECEIVED ❑Zero -flow ❑Water Supply ❑SA ❑Other AUG 0 5 2019 PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 CENTi-U\L FILES DWR SECTION 0 No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Total Copper Total Lead Total Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organicss Benchmarks _ - 100 mg/L or 50 mg/O 6.0 — 9.0 0.010 mg/L 0.075 mg/L 0.126 mg/L 15 mg/L 1 mg/L Parameter Code - 46529 C0530 00400 01119 01051 01094 00552 78141 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Section B, Table 1 to identify the especially sensitive receiving water classifications where the more protective benchmark applies. s Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2018-05/31/2021 SWU-245, last revised 11/1/2018 Page 1 of 3 JULY 2019 Stormwater Discharge Monitoring Report for North Carolina Division of Energy, Mineral and Land Resources General Permit No. NCG030000 Date submitted 08/17/2019 CERTIFICATE OF COVERAGE NO. NCG03 0 2 2 7 SAMPLE COLLECTION YEAR 2019 FACILITY NAME Coming Optical Communications, LLC SAMPLE PERIOD ❑ Jan -June ❑ July -Dec COUNTY Forsyth j R i n ECEIVED or 0 Monthly' July (month) PERSON COLLE ING SAMPLES Jamie Joines 'DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA LABORATORY TestAmerica Laboratories, Inc. Lab Cert. # 434 �uG � 7 Zfl ' ❑Zero -flow ❑Water Supply [—]SA Comments on sample collection or analysis: CENTRAL PILES [:]Other DWR SECTI0`1 Part A: Stormwater Benchmarks and Monitoring Results Date Sample 24-hour rainfall Outfall No. Collected'— � � amount, Total Suspended Solids "(mo/dd/yr) �_ inches3 Bendhinarks 1 100 mg/L or 50 mg/O Parameter Code - 46529 1 C0530 PLEASE REMEMBER -TO SIGN ON PAGES 2 AND/OR 3 ❑� No discharge this period?2 Non -Polar O&G/ pH, Total Copper Total Lead Total Zinc Total Petroleum Total Toxic Organics s Standarrdd units _ Hydrocarbons 6.0 — 9.0 0.010 rng/L 0.075 mg/L 0.126 mg/L 15 mg/L 1 mg/L 00400 01119 01051' 01094 00552 78141 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. "See General Permit, Section B, Table 1 to identify the especially sensitive receiving water classifications where the more protective benchmark applies. s Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). SWU-245, last revised 11/1/2018 Permit Date: 11/1/2018-05/31/2021 _- _ 'Page 1 of 3 AUGUST 2019 Stormwater Discharge Monitoring Report for North Carolina Division of Energy, Mineral and Land Resources General Permit No. NCG030000 Date submitted 091t6/2019 CERTIFICATE OF COVERAGE NO. NCG03 0 2 2 7 FACILITY NAME Coming Optical Communications, LLC COUNTY Forsyth PERSON COLLECTING SAMPLES LABORATORY TestAmerica Laboratories, Inc. Lab Cert. # 434 Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2019 SAMPLE PERIOD ❑ Jan -June Q July -Dec or QMonthly' August (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA lle ❑Zero -flow []water Supply ❑SA Cevlz ❑Other OCT 9 7.2019 PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 C,eNrR4t `��t6T'jplV n No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids PH, Standard units Total Copper Total Lead Total Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organics, Benchmarks - - 100 mg/L or 50 rng/L° 6.0 — 9.0 0.010 mg/L 0.075 mg/L 0.126 mg/L 15 mg/L 1 mg/L Parameter Code - 46529 C0530 00400 01119 01051 01094 00552 78141 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outtall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 'The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Section B, Table 1 to identify the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2018-05/31/2021 5WU-245, last revised 11/1/2018 _--- — — - :page .1 of 3 SEPTEMBER 2019 Stormwater Discharge Monitoring Report for North Carolina Division of Energy, Mineral and Land Resources General Permit No. NCG030000 Date submitted 10/28/2019 CERTIFICATE OF COVERAGE NO. NCG03 0 2 2 7 FACILITY NAME Coming Opticai Communications, LLC COUNTY Forsyth PERSON COLLECTING SAMPLES LABORATORY Testkmerica Laboratories, Inc. Lab Cert. # 434 Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results Outfall No. Date Sample 24-hour rainfall Total Suspended Solids Collected' amount, (mo/dd/yr) Inches' Benchmarks _ - 100 mg/L or 50 mg/L" Parameter Code - 46529 1 C0530 SAMPLE COLLECTION YEAR 2019 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or �Ionthly' ' September --(month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA ❑Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 No discharge this period?2 Non -Polar O&G/ PH, Total Copper Total Lead Total Zinc Total Petroleum Total Toxic Organicss Standard units Hydrocarbons 6.0 — 9.0 0.010 mg/L 0.075 mg/L 0.126 mg/L 15 mg/L 1 mg/L 00400 01119 01D51 01094 00552 78141 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 'The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. " See General Permit, Section B, Table 1 to identify the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469,12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2018-05/31/2021 SWU-245, last revised 11/1/2018 Page 1 of 3 OCTOBER 2019 Stormwater-Dischar e-Monitorin -Re ort for North Carolina Division of Energy, Mineral and Land Resources General Permit No. CERTIFICATE OF COVERAGE NO. N0003 0 2 2 FACILITY NAME Coming Optical Communications, LLC COUNTY Forsyth PERSON COLLECTING SAMPLES LABORATORY TestAmerica Laboratories, Inc. Date submitted 12/13/2019 Lab Cert. # 434 Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results NCG030000 SAMPLE COLLECTION YEAR 2019 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or Donthlyl November (month) DISCHARGING TO CLASS ❑ORW ❑HQW []Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA ❑Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 n No discharge this period?2 Non -Polar O&G/ Outfall No. Date Sample 24-hour rainfall Total Suspended Solids pH, Total Copper Total Lead Total Zinc Total Petroleum Total Toxic Organic 5 Collected' amount, Standard units Hydrocarbons (mo/dd/yr) Inches' Benchmarks _ - 100 mg/L or 50 mg/L4 6.0 — 9.0 0.010 mg/L 0.075 mg/L 0.126 mg/L 15 mg/L 1 mg/L Parameter Code - 46529 C0530 00400 01119 01051 01094 00552 78141 1 10/30/2019 1.58 4.2 6.5 0.0026 <0.001 0.030 <3.8 NIA 1 (lab filtered) 10/30/2019 1.58 6.5 <0.002 <0.001 0.030 NIA 2 10/30/2019 1.58 6.1 7.0 0.0022 <0.001 0.058 <3.8 NIA 2 (lab filtered) 10/30/2019 1.58 7.0 <0.002 <0.001 0.022 NIA n a rwVuny aniNnir, t1"3LCG.+ vi ac1111-an..VP U. ----- -- ' - - - 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 'The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Section 13, Table 1 to identify the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2018-05/31/2021 SWU-245, last revised 11/1/2018 Page 1 of 3 Client Sample Results Client: Corning Optical Communications LLC Job ID: 180-98114-1 Project/Site: Coming OpticalStormwater, Winston Salem Client Sample ID: OF-1 Lab Sample ID: 180-98114-1 Date Collected: 10/30/19 16:05 Matrix: Water Date Received: 11/01/19 09:00 Method: EPA 200.8 Rev 5 - Metals (ICPIMS) - Total Recoverable Analyte Result Qualifier RL MDL Unit Copper 2.6 2.0 0.99 ug1L Lead 0.34 J 1.0 0.16 uglL Zinc 30 5.0 2.2 ug1L General Chemistry D Prepared Analyzed Dil Fac {,1 11/06/19 09:39 11/08/19 19:56 1 11/06/19 09:39 11/08/19 19:56 1 11/06/19 09:39 11/08/19 19:56 1 Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Di[ Fac HEM ND 3.8 1.3 mg/L 11/14/19 09:56 11/14/19 09:56 1 SGT-HEM ND 3.8 1.3 mg1L 11/14/19 09:56 11/14/19 09:56 1 iota[ Suspended Solids 11 4.2 0.50 0.50 mg/L 11/02119 08:36 1 Analyte Result Qualifier RL RL Unit D Prepared Analyzed Dil Fac pH 6.5 HF 0.1 0.1 SU 11/1411917:37 1 Client Sample ID: OF-2 Lab Sample ID. 180-98114-2 Date Collected: 10/30/19 16:10 Matrix: Water Date Received: 11/01/19 09:00 Method: EPA 200.8 Rev 5 - Metals (ICPIMS) -Total Recoverable Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac Copper 2.2 2.0 0.99 ug1L _ 11/06/19 09:39 11/08/19 20:09 1 Lead 0.67 J 1.0 0.16 ug/L 11/06/19 09:39 11/08/19 20:09 1 Zinc 58 5.0 2.2 ug/L 11/06/19 09:39 11/08/19 20:09 1 rGeneral Chemistry Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac HEM ND 3.8 1.3 mg/L 11114119 09:56 11/14/19 09:56 1 SGT-HEM ND 3.8 1.3 mg/L 11114/19 09:56 11/14/19 09:56 1 Total Suspended Solids 6.1 0.50 0.50 mg/L 11/02/19 08:36 1 Analyte Result Qualifier RL RL Unit D Prepared Analyzed Dil Fac PH 4 7.0 HF 0.1 0.1 SU 1111411917:39 1 i Eurofins TestAmerica, Pittsburgh C Page 9 of 19 11 /18/2019 Client Sample Results } Client: Corning Optical Communications LLC Job ID: 180-98109-1 Project/Site: Corning OpticalStormwater, Winston Salem -.• Client Sample ID: OF-1L Lab Sample ID: 180-98109-1 Date Collected: 10/30/19 16:05 Matrix: Water Date Received: 11/01/19 09:00 Method: EPA 200.8 Rev 5 - Metals (ICPIMS) - Dissolved I -a Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Oil Fac Copper 1.1 J 2.0 0.99 ug/L w 11/06/19 19:14 11/14/19 02:50 1 Lead ND 1.0 0.16 ug1L 11/0611919:14 11114/1902:50 1 Zinc 30 5.0 2.2 ug1L 11/06/1919714 11/1411902:50 1 Client Sample ID: OF-21. Lab Sample ID: 180-98109-2 Date Collected: 10/30/19 16:10 Matrix: Water Date Received: 11/01/19 09:00 Method: EPA 200.8 Rev 5 -Metals (ICPIMS) -Dissolved Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Oil Fac Capper ND 2.0 0.99 ug/L 11106119 19:14 11/14/19 02:55 1 Lead NO 1.0 0.16 ug/L 11/06/19 19:14 11/14/19 02:55 1 Zinc 22 5.0 2.2 ug1L 11/06/19 19:14 11/14/19 02:55 1 Client Sample ID: SD-1L Lab Sample ID: 180-98109-3. Date Collected: 10/30/19 16:17 Matrix: Water Date Received: 11/01/19 09:00 Method: EPA 200.8 Rev 5 - Metals (ICPIMS) - Dissolved Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Oil Fac Capper ND 2.0 0.99 uglL 11106/19 19:14 11114/19 03:10 1 Lead ND 1.0 0.16 ug/L 11/06/19 19:14 11/14/19 03:10 1 Zinc 37 5.0 2.2 uglL 11/06/19 19:14 11/14/19 03:10 1 u Client Sample ID: SD-21- Lab Sample ID: 180-98109-4 Date Collected: 10/30/19 16:27 Matrix: Water Date Received: 11/01/19 09:00 Method: EPA 200.8 Rev 5 - Metals (ICPIMS) - Dissolved Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Oil Fac T Copper 1.2 J 2.0 0.99 u911- 11/06/19 19:14 11/14/19 03:15 1 Lead ND 1.0 0.16 uglL 11/06/19 19:14 11/14/19 03:15 1 Zinc 34 5.0 2.2 uglL 11106/1919:14 11/1411903:15 1 ,j Client Sample ID: DS-1L Lab Sample ID: 180-98109-5 Date Collected: 10/30/19 16:11 Matrix: Water Date Received: 11/01119 09:00 Method: EPA 200.8 Rev 5 - Metals (ICPIMS) - Dissolved Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Oil Fac Copper 1.2 J 2.0 0.99 uglL 11/0611919:14 1111411903:20 1 Lead ND 1.0 0.16 ug1L 11/06/1919:14 1111411903:20 1 ri Zinc 130 5.0 2.2 ug1L 11/06/19 19:14 11/14/19 03:20 1 Client Sample ID: DS-2L Lab Sample ID: 180-98109-6 Date Collected: 10/30/19 16:22 Matrix: Water Date Received: 11/01/19 09:00 Method: EPA 200.8 Rev 5 - Metals (ICPIMS) - Dissolved Analyte Result Qualifier Copper NO Lead ND fk RL 2.0 1.0 MDL Unit D Prepared Analyzed Oil Fac 0.99 ug/L 11106119 19:14 11/1411903:25 1 0.16 ug1L 11/0611919:14 11/1411903:25 1 Eurofins TestAmerica, Pittsburgh Page 11 of 19 11 / 15/2019 NOVEMBER 2019 Stormwater Discharge Monitorin Report for North Carolina Division of Energy, Mineral and Land Resources General Permit No. NCG030000 Date submitted 1212012019 CERTIFICATE OF COVERAGE NO. NCG03 0 2 2 7 FACILITY NAME Coming Optical Communications, LLC COUNTY Forsyth PERSON COLLECTING SAMPLES LABORATORY TestAmerica Laboratories, Inc. Lab Cert. ## 434 Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2019 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or Donthly' November (month) DISCHARGING TO CLASS ❑ORW ❑❑T HQW rout ❑PNA RECFIVI_U ❑Zero -flow ❑Water Supply ❑SA DEC 31 2019 ❑other ,_;EN`I-IVf L FILES PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 DWR SECTION n No discharge this neriod?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' Total Suspended Solids pH, Standard units Total Copper Total Lead Total Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organicss Benchmarks _ - 100 mg/L or 50 mg/L° 6.0 — 9.0 0.010 mg/L 0.075 mg/L 0.126 mg/L 15 mg/L 1 mg/L Parameter Code - 46529 C0530 00400 01119 01051 01094 00552 78141 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmarK exceeciance for the same parameter at the same outran. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Section B, Table 1 to identify the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2018-05/31/2021 SWU-245, last revised 11/1/2018 Pagel of 3 DECEMBER 2019 Stormwater Discharge Monitoring Report for North Carolina Division of Energy, Mineral and Land Resources General Permit No. NCG030000 Date submitted 01/20/2020 CERTIFICATE OF COVERAGE NO. N0003 0 2 2 7 FACILITY NAME Coming Optical Communications, LLC COUNTY Forsyth PERSON COLLECTING SAMPLES LABORATORY TestAmerica Laboratories, lnc. Lab Cert. # 434 �� � Comments on sample collection or analysis: �c.F.. FEB zo Part A: Stormwater Benchmarks and Monitoring Results EN I S C pfF[LE.5 SAMPLE COLLECTION YEAR 2020 SAMPLE PERIOD Jan -June 0 July -Dec or [Monthly' December (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply [:]SA ❑Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 --> 0 No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Total Copper Total Lead Total Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics5 Benchmarks _ - 100 mg/L or 50 mg/L4 6.0 — 9.0 0.010 mg/L 0.075 mg/L 0.126 mg/L 15 mg/L 1 mg/L Parameter Code - 46529 C0530 00400 01119 01051 01094 00552 78141 ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. Z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Section B, Table 1 to identify the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469,12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2018-OS/31/2021 SWU-245, last revised 11/1/2018 Page 1 of 3 JANUARY 2020 Stormwater Discharge Monitoring Report for North Carolina Division of Energy, Mineral and Land Resources General Permit No. NCG030000 Date submitted 02/2012020 CERTIFICATE OF COVERAGE NO. NCG03 0 2 2 7 FACILITY NAME Coming Optical Communications, LLC COUNTY Forsyth PERSON COLLECTING SAMPLES LABORATORY TestAmerica Laboratories, Inc. Lab Cert. #i 434 Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2020 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or EMonthly' January _ (month) fT���f\/CS-HARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA f tt ❑Zero -flow ❑Water Supply ❑SA FEB 2- G 2019 ❑Other CEN i h{P,I_ FILES PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 D;NR SECTION ❑ No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Total Copper Total Lead Total Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics5 Benchmarks _ - 100 mg/L or 50 mg/L° 6.0 — 9.0 0.010 mg/L 0.075 mg/L 0.126 mg/L 15 mg/L 1 mg/L Parameter Code - 46529 C0530 00400 01119 01051 01094 00552 78141 1 01/24/2020 1.35 6.0 7.4 0.002 <0.001 0.029 <4.1 2 01 /24/2020 1,35 7.4 7.3 0.0022 <0.001 0.060 <4.1 ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 'For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 'The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. "See General Permit, Section B, Table 1 to identify the especially sensitive receiving water classifications where the more protective benchmark applies. s Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2018-05/31/2021 SWU-245, last revised 11/1/2018 Page 1 of 3 Client Sample Results Client: Corning Optical Communications LLC Project/Site: Corning OpticalStormwater, Winston Salem Client Sample ID: OF-1 Date Collected: 01124/20 07.25 Date Received: 01/25/20 10:00 Method: EPA 200.8 Rev 5 - Metals (ICP/MS) - Total Recoverable Analyte Result Qualifier RL MDL Unit Copper 2.0 2.0 0.69 ug/L Lead 0.47 J 1.0 0.13 ug/L Zinc 29 5.0 4.3 ug/L General Chemistry r Job ID: 180-101507-1 ` Lab Sample ID: 180-101507-1 Matrix: Water D Prepared Analyzed Oil Fac 02/04120 07:02 02/05/20 18:40 1 02/04/20 07:02 02/05/20 18:40 1 02/04/20 07:02 02/05/20 18:40 1 Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac 4 ioi HEM 1.6 J 4.1 1.4 mg1L 02/0512017:19 02105/2017:19 .1 SGT-HEM NO 4.1 1.4 mg/L 0210512017:19 0210512017:19 1 • Total Suspended Solids 6.0 1.0 1.0 mglL 01/28/20 13:26 1 Analyte Result Qualifier RL RL Unit D Prepared Analyzed Dil Fac pH 6.6 HF 0.1 0.1 SU 02/06120 11 :08 i Client Sample ID: OF-2 Date Collected: 01/24/20 07:30 Date Received: 01125/20 10:00 Method: EPA 200.8 Rev 5 - Metals (ICP/MS) - Total Recoverable Analyte Result Qualifier RL MDL Unit Copper 2.2 2.0 0.69 ug/L Lead 0,56 J 1.0 0.13 ug/L Zinc 60 &0 4.3 ug/L General Chemistry Analyte HEM SGT-HEM Total Suspended Solids Analyte pH Lab Sample ID: 180-101507-2 Matrix: Water D Prepared Analyzed Dil Fac 02/04/20 07:02 02105/20 18:43 1 02/04120 07:02 02105/20 18:43 1 02/04/20 07:02 02/05120 18A3 1 Result Qualifier RL MOL Unit D Prepared Analyzed oil Fac 4.1 1A mgll_ 00 7 11.6 NO 4.1 1A mg1L 02/0512017:19 02105/2017:19 1 7.4 0.50 0.50 mg/L 0112812013:26 1 Result Qualifier RL RL Unit D Prepared Analyzed oil Fac 6.9 HF 0.1 0.1 SU _ 0210612011:09 1 Eurofins TestAmerica, Pittsburgh Page 9 of 17 2/10/2020 FEBRUARY 2020 Stormwater Discharge Monitoring Report for North Carolina Division of Energy, Mineral and Land Resources General Permit No. NCG030000 Date submitted 03/16/2020 CERTIFICATE OF COVERAGE NO. NCG03 0 2 2 7 FACILITY NAME Corning Optical Communications, LLC COUNTY Forsyth SAMPLE COLLECTION YEAR 2020 SAMPLE PERIOD ® Jan -June ® July -Dec or E]onthly' February (month) PERSON COLLECTING SAMPLES DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA LABORATORY TestAmerica Laboratories, Inc. Lab Cert. # 434 C.I % , a ,. ❑Zero -flow ❑Water SUPPIY SA Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results MAR 2 3 2020 ❑Other CENTRAL 1L PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 DWR SECTid : (=7 n/ ,a; 1 f1,; __J, 32 Outfall No. Date Sample 1 Collected (mo/dd/yr) 24-hour rainfall amount, Inches' Total Suspended Solids P H Standard units Total Copper ICI Total Lead .w ivi yc Lffla Total Zinc PCI luu: Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organics Benchmarks _ - 100 mg/L or 50 mg/L4 6.0 — 9.0 0.010 mg/L 0.075 mg/L 0.126 mg/L 15 mg/L 1 mg/L Parameter Code - 46529 C0530 00400 01119 01051 01094 00552 78141 ,...11r —f, ."5 1nuLcau vi semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single ouifaii, you must stili submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. ° See General Permit, Section B, Table 1 to identify the especially sensitive receiving water classifications where the more protective benchmark applies. s Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/l/2018-05/31/2021 SWU-245, last revised 11/1/2018 Page 1 of 3 MARCH 2O20 Stormwater Discharge Monitoring Report for North Carolina Division of Energy, Mineral and Land Resources General Permit No. NCG030000 Date submitted 04/10/2020 CERTIFICATE OF COVERAGE NO. NCG03 0 2 2 7 FACILITY NAME Corning Optical Communications, LLC COUNTY Forsyth PERSON COLLECTING SAMPLES e LABORATORY TestAmerica Laboratories, Inc. Lab Cert. # 434 w.T._I 1yD Comments on sample collection or analysis: APR 2 U 2020 CEN1 tV%,L FILES Part A: Stormwater Benchmarks and Monitoring Results DWR SECTION SAMPLE COLLECTION YEAR 2020 SAMPLE PERIOD ❑ Jan -June 1:1 July -Dec or Bnthly' March (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply [:]SA ❑Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 --> ❑■ No discharge this period ?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' Total Suspended Solids pH, Standard units Total Copper Total Lead Total Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organicss Benchmarks _ - 100 mg/L or 50 mg/L4 6.0 — 9.0 0.010 mg/L 0.075 mg/L 0.126 mg/L 15 mg/L 1 mg/L Parameter Code 46529 C0530 00400 01119 01051 01094 00552 78141 ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 'The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Section B, Table 1 to identify the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2018-05/31/2021 SWU-245, last revised 11/1/2018 Page 1 of 3 APRIL 2020 RE0,P\i;=r. MAY 2 9 N-20 CEN'( tV,L ►-ICES DWR SECTION Stormwater Discharge Monitoring Report for North Carolina Division of Energy, Mineral and Land Resources General Permit No. NCG030000 Date submitted 05,152020 CERTIFICATE OF COVERAGE No. NCG03 0 2 2 7 FACILITY NAME Corning OpBcal Communications, LLC COUNTY Forsyth PERSON COLLECTING SAMPLES LABORATORY TestAmerica Laboratories, Inc. Lab Cert. # 434 Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2020 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or QVlonthly' April (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA ❑Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 n No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' Total Suspended Solids pH, Standard units Total Copper Total Lead Total Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics' Benchmarks - 100 mg/L or 50 mg/L' 6.0 — 9.0 0.010 mg/L 0.075 mg/L 0.126 mg/L 15 mg/L 1 mg/L Parameter Code - 46529 C0530 00400 01119 01051 01094 00552 78141 1 04/23/2020 0.25 4.0 7.9 0.004 <0.001 0.043 <5 4 2 04/23/2020 0.25 52 7.9 0.0094 0.0029 0.110 <5.4 ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 1 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 'The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver ofthe rain gauge requirement. ^ See General Permit, Section B, Table 1 to identify the especially sensitive receiving water classifications where the more protective benchmark applies. ' Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date:11/1/2018-OS/31/2021 SWU-245, last revised 11/1/2018 Page 1 of 3 Client Sample Results Client: Corning Optical Communications LLC Project/Site: Corning Optical Stormwater, Winston Salem Client Sample ID: OUTFALL 1 Date Collected: 04/23/20 10:30 Date Received: 04/24/20 08:30 Method: EPA 200.8 Rev 5 - Metals (ICP/MS) - Total Recoverable Analyte Result Qualifier RL Copper 4.0 B 2.0 Lead 0.34 J 1.0 Zinc 43 5.0 General Chemistry Analyte Result Qualifier HEM (Oil & Grease) ND TPH ND Total Suspended Solids 4.0 Analyte Result Qualifier pH 6.6 HF Job ID: 180-105000-1 Lab Sample ID: 180-105000-1 Matrix: Water MDL Unit D Prepared Analyzed Dil Fac 0.69 ug/L 04/28/20 11:27 05/01/20 2012 1 0.13 ug/L 04/28/20 11:27 05/01/20 20:12 1 4.3 ug/L 04/28/20 11:27 05/01/20 20:12 1 RL MDL Unit D Prepared Analyzed Dil Fac 5.4 1.5 mg/L 04/27/20 06:40 04/27/20 10:40 1 5.4 1.5 mg/L 04/27/20 06:40 04/27/20 10:40 1 1.0 1.0 mg/L 04/29/2016:07 • 1 RL RL Unit D Prepared Analyzed Dil Fac 0.1 0.1 SU 05/05/20 09:14 1 Client Sample ID: OUTFALL 2 Lab Sample ID: 180-105000-2 Date Collected: 04/23/20 10:38 Matrix: Water Date Received: 04/24/20 08:30 Method: EPA 200.8 Rev 5 - Metals (ICP/MS) - Total Recoverable Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac Copper 9.4 B 2.0 0.69 ug/L 04/28/20 11:27 05/01/20 20.16 1 Lead 2.9 1.0 0.13 ug/L 04/28/20 11:27 05/01/20 20:16 1 Zinc 110 5.0 4.3 ug/L 04/28/20 11:27 05/01/20 20:16 1 General Chemistry Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac HEM (Oil & Grease) ND 5.4 1.5 mg/L 04/27/20 06:40 04/27/20 10:40 1 TPH ND 5.4 1.5 mg/L 04/27/20 06:40 04/27/20 10:40 1 Total Suspended Solids 52 1.4 1.4 mg/L 04/29/20 16:07 1 Analyte Result Qualifier RL RL Unit D Prepared Analyzed Dil Fac pH 7.2 HF 0.1 0.1 SW_ 05/05/20 09:17 1 Eurofins TestAmerica, Pittsburgh Page 9 of 15 5/8/2020 MAY 2020 Stormwater Discharge Monitoring Report for North Carolina Division of Energy, Mineral and Land Resources General Permit No. NCG030000 Date submitted 06/15/2020 CERTIFICATE OF COVERAGE NO. NCG03 0 2 2 7 FACILITY NAME Corning Optical Communications, LLC COUNTY Forsyth PERSON COLLECTING SAMPLES LABORATORY TestAmerica Laboratories. Inc. Lab Cert. # 434 Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results JUN 2 3 2020 VI AL FILES DWR SECTION SAMPLE COLLECTION YEAR 2020 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec orNethlyl May (month) DISCHARGING TO CLASS DORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply [:]SA ❑Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ❑■ No discharge this period?' Outfall No. e Date Sample Collected (mo/dd/yr) 24 hour rainfall amount, Inches' Total Suspended Solids Standard and units Total Copper Total Lead Total Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organics ' Benchmarks _ - 100 mg/L or 50 mg/L4 6.0 — 9.0 0.010 mg/L 0.075 mg/L 0.126 mg/L 15 mg/L 1 mg/L Parameter Code 46529 C0530 00400 01119 01051 01094 00552 78141 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. Z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. ' See General Permit, Section B, Table 1 to identify the especially sensitive receiving water classifications where the more protective benchmark applies. ' Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2018-05/31/2021 SWU-245, last revised 11/1/2018 Page 1 of 3 JUKE 2020 Stormwater Discharge Monitoring Report for North Carolina Division of Energy.. Mineral and Land Resources General Permit No. NCG030000 Date submitted 07/10/2020 CERTIFICATE OF COVERAGE NO. NCG03 0 2 2 7 FACILITYNAME v::,•,;r�icsi; .,,.sniiratiarss,LLC —� COUNTY Forsyth PERSON COLLECTING SAMPLES LABORATORY TestAmerica Laboratories, Inc. Lab Cert. ## 434 Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2020 SAMPLE PERIOD ® Ian4sinp ❑ July -Dec orhEthlyl June (month) DISCHARGING TO CLASS7[]ORW ❑HQW ❑Trout ❑PNA ❑Zero flow ❑Water Supply [:]SA [—]Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ■ No discharge this period?2 outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches; Total Suspended Solids PH, Standard units Total Copper Total Lead Total Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organicss Benchmarks _ - 100 mg/L or 50 mg/V 6.0 — 9.0 0.010 mg/L 0.075 mg/L 0.126 mg/L 15 mg/L 1 mg/L Parameter Code - 46529 C0530 004W 01119 01051 01094 00552 78141 ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. Z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. ° See General Permit, Section B, Table 1 to identify the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2018-05/31/2021 SWU-245, last revised 11/1/2018 Page 1 of 3 JULY 2020 Stormwater Discharge Monitoring Report for North Carolina Division of Energy, Mineral and Land Resources General Permit No. NCG030000 Date submitted 08/20/2020 CERTIFICATE OF COVERAGE NO. NCG03 0 2 2 7 FACILITY NAME Corning Optical Communications, LLC COUNTY Forsyth PERSON COLLECTING SAMPLES LABORATORY TestAmerica Laboratories, Inc. Lab Cert. # 434 Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2020 SAMPLE PERIOD Jan -June ❑ July -Dec orNothlyl July (month) DISCHARGING TO CLASS_]ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply [:]SA ❑Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 W No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches s Total Suspended Solids pH, Standard units Total Copper Total Lead Total Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organic. Benchmarks _ - 100 mg/L or 50 mg/O 6.0 — 9.0 0.010 mg/L 0.075 mg/L 0.126 mg/L 15 mg/L 1 mg/L Parameter Code - 46529 C0530 00400 01119 01051 01094 00552 78141 ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. a See General Permit, Section B, Table 1 to identify the especially sensitive receiving water classifications where the more protective benchmark applies. s Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2018-05/31/2021 SWU-245, last revised 11/1/2018 Page 1 of 3 AUGUST 2020 Stormwater Discharge Monitoring Report for North Carolina Division of Energy, Mineral and Land Resources General Permit No. NCG030000 CERTIFICATE OF COVERAGE NO. NCG03 0 2 2 7 FACILITY NAME COUNTY Forsyth Coming Optical Communications, LLC Date submitted 09/14/2020 PERSON COLLECTING SAMPLES LABORATORY TestAmerica Laboratories, Inc. Lab Cert. # 434 Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2020 SAMPLE PERIOD F] Jan -June July -Dec or E Monthly' August (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water supply ❑SA ❑Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ❑■ No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Total Copper Total Lead Total Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organics' Benchmarks _ - 100 mg/L or 50 mg/L4 6.0 — 9.0 0.010 mg/L 0.075 mg/L 0.126 mg/L 15 mg/L 1 mg/L Parameter Code - 46529 C0530 00400 01119 01051 01094 00552 78141 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 'The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites maybe eligible for a waiver of the rain gauge requirement. 4 See General Permit, Section B, Tabled to identify the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2018-05/31/2021 5WU-245, last revised 11/1/2018 Page 1 of 3 SEPTEMBER 2020 NCDEQ Division of Energy, Mineral and Land Resources StormWater Discharge Monitoring Report (®MR) Form for NCG030000 Metal Fabrication Click here for instructions Complete, sign, scan and submit the DMRvia the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form, within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMRto the aoorooriate DEMLR Regional Office. Certificate of Coverage No. NCG03 0 2 2 7 Person Collecting Samples: Darren Swart Facility Name: Corning Optical Communications, LLC Laboratory Name: TestAmercica Laboratories, Inc; Facility County: Forsyth Laboratory Cert. No.: 434 Discharge during this period: ❑■ Yes ❑ No (if no, skip to signature and date) Has your facility implemented mandatory Tier response actions for any benchmark exceedances? ❑ Yes ❑ No If so, which Tier (1, 11, or III)? Analytical Monitoring; Requirements for Outfalls with Industrial Activities —Benchmarks in (Red) Parameter Code Parameter Outfall Outfall Outfall I Outfall Outfall N/A Receiving Stream Class 1 2 1-Diss 2-Disc N/A Date Sample Collected MM/DD/YYYY 09/17/2020 09/17/2020 09/17/2020 I 09/17/2020 46529 24-Hour Rainfall in inches 0.25 0.25 0.25 I 0.25 00552 Non -Polar Oil &Grease in mg/L (15) 2.5 2.5 N/A I N/A C0530 TSS in mg/L (100 or 50*) 2.7 34 N/A N/A 00400 pH in standard units (6.0-9.0) 7.5 8.1 7.5 8.1 NCOIL New Motor/Hydraulic Oil Usage in N/A N/A N/A N/A gal/month 01119 Copper, total recoverable in mg/L 0.0023 0.0055 0..0014 0.0023 (0.010 FW, 0.005 SW) 01051 Lead, total recoverable in mg/ L 0.00046 0.0017 N/A N/A (0.075 FW, 0.220 SW) 01094 Zinc, total recoverable in mg/ L (0.126 0.030 0.082 0.023 0.029 FW, 0.095 SW) 78141 Total Toxic Organics (TTO) in mg/L(1) N/A N/A N/A N/A * Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA) have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L. Notes (optional): "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, orthose persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing vi tion .' "OrDele'g64WUthorized Individual Date Client Sample Results Client: Corning Optical Communications LLC Job ID: 180-111131-1 Project/Site: Corning Optical Stormwater, Winston Salem Client Sample ID: OUTFALL 001-20200917 Lab Sample ID: 180-111131-1 Date Collected: 09/17/20 09:42 Matrix: Water Date Received: 09/18/20 07:50 Method: EPA 200.8 Rev 5 - Metals (ICP/MS) - Total Recoverable Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac Copper 2.3 B 2.0 0.69 ug/L 09/28/2015:32 10/01/2014:12 1 Lead 0.46 J B 1.0 0.13 ug/L 09/28/20 15:32 10/01/20 14:12 1 Zinc 30 B 5.0 4.3 ug/L 09/28/2015:32 10/01/2014:12 1 General Chemistry Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac HEM (Oil & Grease) 2.5 J B F7 F2 4.7 1.3 mg/L 09/30/2016:49 10/01/2017:31 1 TPH ND F1 4.7 13 mg/L 09/30/2016:49 10/01/2017:31 1 Total Suspended Solids 2.7 0.50 0.50 mg/L 09/22/2014:23 1 Analyte Result Qualifier RL RL Unit D Prepared Analyzed Dil Fac pH 6.8 HF 0.1 0.1 SU 09/25/2017:19 1 Client Sample ID: OUTFALL 001-DISS-20200917 Lab Sample ID: 180-111131-2 Date Collected: 09/17/20 09:42 Matrix: Water Date Received: 09/18/20 07:50 Method: EPA 200.8 Rev 5 - Metals (ICP/MS) - Dissolved Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac Copper 1.4 J B 2.0 0.69 ug/L 09/28/2015:32 10/01/2014:23 1 Zinc 23 B 5.0 4.3 ug/L 09/28/2015:32 10/01/2014:23 1 Client Sample ID: OUTFALL 002-20200917 Lab Sample ID: 180-111131-3 Date Collected: 09/17/20 09:44 Matrix: Water Date Received: 09/18/20 07:50 Method: EPA 200.8 Rev 5 - Metals (ICP/MS) - Total Recoverable Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac Copper 5.5 B 2.0 0.69 ug/L 09/28/2015:32 10/01/2014:25 1 Lead 1.7 B 1.0 0.13 ug/L 09/28/2015:32 10/01/2014:25 1 Zinc 82 B 5.0 4.3 ug/L 09/28/2015:32 10/01/2014:25 1 General Chemistry Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac HEM (Oil & Grease) 2.5 J B 4.8 1.3 mg/L 09/30/20 16:49 10/01/20 17:31 1 TPH ND 4.8 1.3 mg/L 09/30/2016:49 10/01/2017:31 1 Total Suspended Solids 34 0.83 0.83 mg/L 09/22/20 14:23 1 Analyte Result Qualifier RL RL Unit D Prepared Analyzed Dil Fac pH 7.2 HF 0.1 0.1 SU 09/25/2017:27 1 Client Sample ID: OUTFALL 002-DISS-20200917 Lab Sample ID: 180-111131-4 Date Collected: 09/17/20 09:44 Matrix: Water Date Received: 09/18/20 07:50 Method: EPA 200.8 Rev 5 - Metals (ICP/MS) - Dissolved Analyte Result Qualifier RL MDL Unit D Prepared Analyzed Dil Fac Copper 2.3 B 2.0 0.69 ug/L 09/28/2015:32 10/01/2014:28 1 Zinc 29 B 5.0 4.3 ug/L 09/28/2015:32 10/01/2014:28 1 Eurofins TestAmerica, Pittsburgh Page 10 of 16 10/5/2020 OCTOBER 2020 1336.771.8080 ng ical CORNING 31801CenttrretPark Boulevardcations f 336.771.8050 Winston-Salem, f_ 27107 USA www.coming.com November 24, 2020 DEQ Winston-Salem Regional Office Attn: DEMLR Stormwater Program 450 West Hanes Mill Road Suite 300 Winston-Salem, NC 27105 RE: Stormwater Discharge Monitoring Report Certificate of Coverage No. NCG030227 Dear Sir/Madam: The Corning Optical Communications facility located at 3180 Centre Park Blvd., Winston Salem, NC currently operates under General Permit No. NCG030000, as evidenced by Certificate of Coverage No. NCG030227. Corning -Winston Cable Plant (WCP) did not have a discharge meeting the permit criteria for sampling during the month of October 2020. Ifyou have any questions, do not hesitate to contact me at (336) 771-8030. Sincerely, YrCP Plant Ma Corning Optical Communications, LLC Corning Restricted NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report (DMR) Form for NCG030000 Metal Fabrication Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form, within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEM LR Regional Office. Certificate of Coverage No. NCG031 OI 2 12 17 i Person Collecting Samples: N4 Facility Name: Coming Optical Communications LLC-Winston Cable Laboratory Name: TestAmerica Laboratories Facility County: Forsyth Laboratory Cert. No.: 434 Discharge during this period: Yes Ei No (ifno, skip to signature and date) Has your facility implemented mandatory Tier response actions for any benchmark exceedances? 1J Yes 0 N o If so, which Tier (1, 11, or III)? Analytical Monitoring Requirements for Outfalls with Industrial Activities - Benchmarks in (Red) Parameter Parameter OutPall OutPall OutPall OutPall OutPall Code N/A Receiving Stream Class N/A Date Sample Collected MM/DD/YYYY 46529 24^Hour Rainfall in inches 00552 Non -Polar Oil & Grease in mg/L (15) C0530 TSS in mg/L (100 or SO*) 00400 pH in standard units (6.0 - 9.0) New Motor/Hydraulic Oil Usage in NCOIL gal/month 01119 Copper, total recoverable in mg/L (0.010 FW, 0.005 SW) Lead, total recoverable in mg/ L 01051 (0.075 FW, 0.220 SW) Zinc, total recoverable in mg/ L (0.126 01094 FW, 0.095 SW) 78141 Total Toxic Organics (TTO) in mg/L{I) g ( W), Quality ( R) Primary Nursery ( ) OutFalls to Outstanding Resource Waters OR H' Quali Waters HQW), Trout Waters raid Prima Nurse Areas PNA have a benchmark TSS limit of 5D mg/L Al other water classifications have a benchmark of 10D mg/L I Notes (optional): "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I an aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowingyaplations."� Authorized Individual 1/-z7• : 20zo Date