HomeMy WebLinkAboutSW6201201_1641 Volumes Required_20201210Static Line Brewery Required Storm Volume Pond #1 Drainage Area: 10.61 acres 462,389 sf Impervious Area: 351,118 sf (8.06 ac) Impervious: 75.9% 1 inch Storm Event: Rv = 0.05+0.009 1 Rv = runoff coefficient 1= percent impervious Rv=0.05+0.009*75.9% = 0.7331 For volume that must be controlled: Volume=3,630*Rd*Rv*A Volume required = 3,630*(1 inch)*(0.7331)*10.61acres = 28,235 cf Volume provided = 71,700 cf Forebay vol = 12,441 cf (18.3%) SA/DA ratio is 1.28 for a depth of 3 feet Required surface area = 10.61ac * (.0128) = 0.1358ac or 5,916 sf Surface area provided = 16,020 sf 409 Chicago Drive, Suite 112, FayetteviIle. NC 28306 office 1 910-426-6777 fax 1 910-426-5777 On time, every time. I www.4Dsitesolut!ons.com