Loading...
HomeMy WebLinkAboutSW6201201_1641 POND 1 drawdown_20201210STATIC LINE BREWERY Drawdown Time Temporary storage volume = Orifice #Idiameter= Area of orifice = Orifice #2 diameter = Area of orifice = Orifice Coefficient (Cd) _ Orifice elevation -- Water elevation --- Driving head (H) _ Discharge (Q) _ Drawdown time = 41,443 cf 3.25 in 1 0.0576 sf 0 in 0 0.0000 sf 0.60 368.50 ft 370.63 ft 0.71 ft 0.2338 cfs 177287 s 49.2 hr 2_1 days 1641 POND 1 drawdown.xlsx Printed 12/10/2020