HomeMy WebLinkAboutNCS000325_Inspection Report_20201119ROY COOPER Governor MICHAEL S. REGAN Secretary S. DANIEL SMITH Director Myers Industries Attention: Marlo Carter P.O. Box H Roanoke Rapids, NC 27870 NORTH CAROLINA Environmental Quality November 19, 2020 Subject: Compliance Evaluation Inspection Myers Industries - Patch Rubber NPDES Individual Stormwater Permit NCS000325 Halifax County, North Carolina Dear Mr. Carter: Enclosed please find a copy of the Compliance Evaluation Inspection Report for the inspection I conducted at the subject facility on November 18, 2020. The report should be self-explanatory; however, should you have any questions concerning this report, please do not hesitate to contact me at (919) 707-3648 or by email at aana.gambleCa)ncdenr.,gov. Sincerely, Aana Gamble Environmental Specialist II Land Quality Section Enclosure: Inspection Report CC: Marlo Carter, Myers Industries, mcarter@patchrubber.com Thad Valentine, DEMLR Raleigh Regional Office, thad.valentine@ncdenr.gov D E North Carolina Department of Environmental Quality I Division of Energy, Mineral and Land Resources NORTH CAROI.JN/ Asheville Regional Office 12090 U.S. Highway 70 ( Swannanoa, North Carolina 28778 D"w-tote�.i�,e W0.1� /"'� 828.296.4500 Compliance Inspection Report Permit: NCS000325 Effective: 05/01/09 Expiration: 04/30/14 Owner: Myers Industries SOC: Effective: Expiration: Facility: Myers Industries - Patch Rubber County: Halifax 100 Patch Rubber Rd Region: Raleigh Weldon NC 27890 Contact Person: Marlo Carter Title: Phone: 252-536-2574 Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 11/18/2020 Primary Inspector: Aana C Gamble Secondary Inspector(s): Entry Time 01:15PM Reason for Inspection: Routine Permit Inspection Type: Stormwater Discharge, Individual Facility Status: ® Compliant Not Compliant Question Areas: Storm Water (See attachment summary) Certification Phone: Exit Time: 02:30PM Phone: 919-707-3648 Inspection Type: Compliance Evaluation Page 1 of 3 Permit: NCS000325 Owner - Facility: Myers Industries Inspection Date: 11/18/2020 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: On November 18, 2020, this facility was inspected for compliance. I met with Mario Carter and Ashley Curry for the inspection. During the inspection, no compliance issues were found. The SWPPP was complete and up-to-date. The facility is in Tier 3 for Zinc, and all requirements were met. Both outfalls were observed and found to be in good condition. This inspection was conducted in part to assess compliance for the permit renewal. Changes in the draft permit were reviewed with Mr. Carter and Ms. Curry to remind them of changing conditions, especially with regards to the Zinc benchmark. I noted no concerns during the inspection, and the draft permit can be issued as written. Page 2 of 3 Permit: NCS000325 Owner - Facility: Myers Industries Inspection Date: 11/18/2020 Inspection Type : Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Does the site have a Stormwater Pollution Prevention Plan? # Does the Plan include a General Location (USGS) map? # Does the Plan include a "Narrative Description of Practices"? # Does the Plan include a detailed site map including outfall locations and drainage areas? # Does the Plan include a list of significant spills occurring during the past 3 years? # Has the facility evaluated feasible alternatives to current practices? # Does the facility provide all necessary secondary containment? # Does the Plan include a BMP summary? # Does the Plan include a Spill Prevention and Response Plan (SPRP)? # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? # Does the facility provide and document Employee Training? # Does the Plan include a list of Responsible Party(s)? # Is the Plan reviewed and updated annually? # Does the Plan include a Stormwater Facility Inspection Program? Has the Stormwater Pollution Prevention Plan been implemented? Comment: The previous inspection (08/01/2011) recommended that employee training records be kept with the SWPPP. During this inspection, the employee training records were found to be complete, thorough, and maintained with the SWPPP. Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? S ❑ ❑ ❑ Comment: Analytical Monitorinq Yes No NA NE Has the facility conducted its Analytical monitoring? 0 ❑ ❑ ❑ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ ❑ 0 ❑ Comment: Records are well -kept. This permittee is in Tier 3 status for Zinc, and monthly monitoring records are complete and organized. Note that the renewed permit will have a higher benchmark for Zinc in accordance with the 2013 DEMLR stormwater benchmark revision. Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? 0 ❑ ❑ ❑ # Were all outfalls observed during the inspection? M ❑ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ 0 ❑ # Has the facility evaluated all illicit (non stormwater) discharges? 0 ❑ ❑ ❑ Comment: Outfall 001 was dry, clean, and structurally intact. Outfall 002 had a slight trickle of water, which was clean and free of solids or debris. Page 3 of 3