Loading...
HomeMy WebLinkAboutNCG050412_DMR_20200128Mid Atlantic Engineering & Enwronmental Solutions January 28, 2020 NCDEQ/DWR Attention: Central Files 1617 Mail Service Center RECFIVED Raleigh, North Carolina 27699-1617 MAR 2 0 2020 Subject: STORMWATER SAMPLING RESULTS CEN I RAC FILES WELLMARK, LLC DWR SECTION 355 WAKETA DRIVE ASHEBORO, RANDOLPH COUNTY, NORTH CAROLINA PERMIT NCGO50412 MID -ATLANTIC JOB NO.000R2947.10 To Whom it May Concern: 409 Rogers View Court Raleigh, NC 27610 office 919.250.9918 facsimile 919.250.9950 MAAONLINE.COiM Attached please find the Stormwater Discharge Monitoring Reports (DMR) and analytical report for the sampling conducted at the above -referenced site. A stormwater sample was collected from Outfall 001 AND 002 on January 15, 2020 and analyzed for total suspended solids (TSS) and oil and grease (O&G). As indicated on the attached DMR, all parameters were reported below or within their respective benchmark values. If you have any questions or need additional information, please contact me at 919-250-9918. Sincerely, MID -ATLANTIC ASSOCIATES, INC. Paul W. Spangenberg Director of Environmental Compliance Services Attachments: Stormwater Discharge Monitoring Reports Laboratory Analytical Report EXPERIENCED CUSTOMER FOCUSED INNOVATIVE North Carolina Department of Environmental Quality (DEQ) SEMI-ANNUAL STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT Vehicle/Equipment Maintenance Activities Only Date submitted 1/28/2020 CERTIFICATE OF COVERAGE NO. NCG 50,412 FACILITY NAME Wellmark, LLC COUNTY Randolph PERSON COLLECTING SAMPLES Tenesa Hurley LABORATORY Con -test Lab Cert. # 625 SAMPLE COLLECTION YEAR 2020 PLEASE REMEMBER TO SIGN ON "'lir'tE REVERSE 4 Vehicle Maintenance Area (VMA) Stormwater Monitoring Results: Only for facilities using an average of > 55 gal of new motor oil per month. Total event rainfall' .18 or ❑ No discharge this periodz Outfall No. Sample Collected, mm/dd/yr Total Suspended Solids (TSS), mg/L Non -polar O&G/TPH, mg/L (Method 1664 SGT-HEM) (if applicable) Oil and Grease, mg/L (if applicable) pH, Standard units (only if applicable) New Motor Oil or Hydraulic Oil Usage, Annual average gal/mo Benchmark - 100 or 503 15 30 Within 6.0 — 9.0 - 01 1 /15/2020 10 1.2 N/A N/A 300 1 The total precipitation must be recorded using data from an on -site rain gauge. z For sampling periods with no discharge at any outfalls. You must still submit this discharge monitoring report with a checkmark here. 'See General Permit text that identifies the especially sensitive receiving water classifications where the more protective TSS benchmark applies. *FOR MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO ❑■ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO REGIONAL OFFICE CONTACT NAME: NC Stormwater Program NPDES Permit Vehicle/Equipment Maintenance Activities SDMR Last Revised.• June 1, 2018 Page 1 of 2 Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results (or at end of monitoring period in the case of "No Discharge" reports) to DWR Central Files: Division of Water Resources* Attn: Central Files 1617 Mail Service Center Raleigh, NC 27699-1617 *Note this address is correct for Central Files (DWR) and is NOT supposed to be DEMLR. YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." 01 22I &"?o (Date) Additional copies of this form may be downloaded at: https://deg.nc.�,,ov/about/divisions/energy-mineral-land-resources/npdes-stormwater-gps NC Stormwater Program NPDES Permit Vehicle/Equipment Maintenance Activities SDMR Last Revised: June 1, 2018 Page 2 of 2 North Carolina Department of Environmental Quality (DEQ) SEMI-ANNUAL STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT Vehicle/Equipment Maintenance Activities Only Date submitted 1/28/2020 CERTIFICATE OF COVERAGE NO. NCG 50,412 FACILITY NAME Wellmark, LLC COUNTY Randolph PERSON COLLECTING SAMPLES Tenesa Hurley LABORATORY Con -test Lab Cert. # 625 SAMPLE COLLECTION YEAR 2020 PLEASE PIMfE.MSER TO SIGN ON THE WERSE 4 Vehicle Maintenance Area (VMA) Stormwater Monitoring Results: Only for facilities using an average of > 55 gal of new motor oil per month. Total event rainfall' .18 or ❑ No discharge this period' Outfall No. Sample Collected, mm/dd/yr Total Suspended Solids (TSS), mg/L Non -polar O&G/TPH, mg/L (Method 1664 SGT-HEM) (if applicable) Oil and Grease, mg/L (if applicable) pH, Standard units (only if applicable) New Motor Oil or Hydraulic Oil Usage, Annual average gal/mo Benchmark - 100 or 503 15 30 Within 6.0 — 9.0 - 01 1 /15/2020 10 1.2 N/A N/A 300 1 The total precipitation must be recorded using data from an on -site rain gauge. 2 For sampling periods with no discharge at any outfalls. You must still submit this discharge monitoring report with a checkmark here. 3See General Permit text that identifies the especially sensitive receiving water classifications where the more protective TSS benchmark applies. *FOR MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO ❑■ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO REGIONAL OFFICE CONTACT NAME: NC Stormwater Program NPDES Permit Vehicle/Equipment Maintenance Activities SDMR Last Revised: June 1, 2018 Page 1 of 2 Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results (or at end of monitoring period in the case of "No Discharge" reports) to DWR Central Files: Division of Water Resources* Attn: Central Files 1617 Mail Service Center Raleigh, NC 27699-1617 *Note this address is correct for Central Files (DWR) and is NOT supposed to be DEMLR. YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." .01 2zlZ�zc-, (Date) Additional copies of this form may be downloaded at: https://deg.nc.gov/about/divisions/enemy-mineral-land-resources/npdes-stormwater-gps NC Stormwater Program NPDES Permit Vehicle/Equipment Maintenance Activities SDMR Last Revised: June 1, 2018 Page 2 of 2 con -test® ANALYTICAL LABORATORY 39 Spruce Street' East Longmeadow, MA 01028 ' FAX 413/525-6405 ' TEL. 413/525-2332 January 27, 2020 Paul Spangenberg Mid -Atlantic Associates, Inc. - Raleigh, NC 409 Rogers View Court Raleigh, NC 27610 Project Location: Wellmark Client Job Number: Project Number: R2947.10 Laboratory Work Order Number: 20A0840 Enclosed are results of analyses for samples received by the laboratory on January 17, 2020. If you have any questions concerning this report, please feel free to contact me. Sincerely, Kerry K. McGee Project Manager Table of Contents Page 1 of 13 Table of Contents Table of Contents Sample Summary Case Narrative Sample Results 20A0840-01 20A0840-02 Sample Preparation Information QC Data Conventional Chemistry Parameters by EPA/APHA/SW-846 Methods (Total) B250356 B250434 B250531 Flag/Qualifier Summary Certifications Chain of Custody/Sample Receipt 3 4 5 5 6 7 8 8 8 8 8 9 10 11 Page 2 of 13 Table of Contents Jill I I k eel ANALYTICAL LABORATORY 39 Spruce Street . East Longmeadow, MA 01028 ` FAX 413/525-6405 . TEL. 413/525-2332 Mid -Atlantic Associates, Inc. - Raleigh, NC 409 Rogers View Court REPORT DATE: 1/27/2020 Raleigh, NC 27610 PURCHASE ORDER NUMBER: ATTN: Paul Spangenberg PROJECT NUMBER: R2947.10 ANALYTICAL SUMMARY WORK ORDER NUMBER: 20A0840 The results of analyses performed on the following samples submitted to the CON -TEST Analytical Laboratory are found in this report. PROJECT LOCATION: Wellmark FIELD SAMPLE # LAB ID: MATRIX SAMPLE DESCRIPTION TEST SUB LAB 1 20A0840-01 Water 2 20A0840-02 Water EPA 1664B SM21-22 2540D EPA 1664B SM21-22 2540D Page 3of13 Table of Contents Ali I I AW ANALYTICAL LABORATORY 39 Spruce Street' East Longmeadow, MA 01028 . FAX 413/525-6405 . TEL. 413/525-2332 CASE NARRATIVE SUMMARY All reported results are within defined laboratory quality control objectives unless listed below or otherwise qualified in this report. The results of analyses reported only relate to samples submitted to the Con -Test Analytical Laboratory for testing. I certify that the analyses listed above, unless specifically listed as subcontracted, if any, were performed under my direction according to the approved methodologies listed in this document, and that based upon my inquiry of those individuals immediately responsible for obtaining the information, the material contained in this report is, to the best of my knowledge and belief, accurate and complete. f� Lisa A. Worthington Technical Representative Page 4 of 13 Table of Contents IN tek ANALYTICAL LABORATORY 39 Spruce Street' East Longmeadow, MA 01028 ' FAX 413/525-6405 ' TEL. 413/525-2332 Project Location: Wellmark Sample Description: Work Order: 20A0840 Date Received: 1/17/2020 Field Sample #: 1 Sampled: 1/15/2020 11:00 Samole ID: 20A0840-01 Samole Matrix: Water Conventional Chemistry Parameters by EPA/APHA/SW4146 Methods (Total) Date Date/Time Analyte Results RL DL Units Dilution Flag/Qual Method Prepared Analyzed Analyst Total Suspended Solids 10 2.0 0.82 mg/L I SM21-22 2540D 1/19/20 1/19120 11:09 LL Oil & Grease (HEM) 1.2 1.4 1.0 mg/L 1 J EPA 1664B 1/21/20 1/21/20 14:00 LL Page 5 of 13 Table of Contents r I � 0 ANALYTICAL LABORATORY 39 Spruce Street' East Longmeadow, MA 01028 ' FAX 413/525-6405 ' TEL. 413/526-2332 Project Location: Wellmark Sample Description: Work Order: 20A0840 Date Received: 1/17/2020 Field Sample #: 2 Sampled: 1/15/2020 11:00 Sample ID: 20A0840-02 Samole Matrix: Water Comentional Chemists Parameters by EPA/APHA/SW-846 Methods (Total) Date Date/Time Analyte Results RL DL Units Dilution Flag/Qua[ Method Prepared Analyzed Analyst Total Suspended Solids 4.0 2.0 0.82 mg/L 1 SM21-22 2540D 1/19/20 1/19/20 11:09 LL Oil & Grease (HEM) ND 2.8 2.0 mg/L 1 EPA 1664B 1/22/20 1/22/20 13:35 LL Page 6 of 13 con-tcst"' ANALYTICAL LABORATORY 39 Spruce Street' East Longmeadow, MA 01028' FAX 413/525-6405' TEL. 413/525-2332 Sample Extraction Data EPA 1664B Lab Number [Field ID[ Batch Initial [m1 l Date 20A0840-01[11 B250434 980 01/21/20 EPA 1664B Lab Number [Field ID[ Batch Initial [mL1 Date 20A0840-02 [21 B250531 500 01;22/20 �9Tu iT6�34.ifIL7 Table of Contents Lab Number [Field ID] Batch Initial ImL[ Date 20A0840-01[1) B250356 250 01/19/20 20A0840-02 [2) B250356 250 01/19/20 Page 7 of 13 Table of Contents AMALYTICAL LABORATORY 39 Spruce Street' East Longmeadow, MA01028' FAX 413/525-6405' TEL. 413/525-2332 FLAG/QUALIFIER SUMMARY ' QC result is outside of established limits. t Wide recovery limits established for difficult compound. $ Wide RPD limits established for difficult compound. # Data exceeded client recommended or regulatory level ND Not Detected RL Reporting Limit is at the level of quantitation (LOQ) DL Detection Limit is the lower limit of detection determined by the MDL study MCL Maximum Contaminant Level Percent recoveries and relative percent differences (RPDs) are determined by the software using values in the calculation which have not been rounded, No results have been blank subtracted unless specified in the case narrative section. 1 Detected but below the Reporting Limit (lowest calibration standard); therefore, result is an estimated concentration (CLP 1-Flag). Page 9 of 13 rlr A11111 �w 14W V . tat ANALYTICAL LABORATORY 39 Spruce Street . East Longmeadow, MA 01028 ' FAX 413/525-6405 ' TEL. 413/525-2332 CERTIFICATIONS Certified Analyses included in this Report Anslyte Certifications EPA 1664B in Water Oil & Grease (HEM) CT,MA NH,NY,RI,NC,ME,VA SM21-212540D in Water Total Suspended Solids CT,MANH,NY,RI,NC,ME,VA The CON -TEST Environmental Laboratory operates under the following certifications and accreditation: Code Description Number Expires AIHA AIHA-LAP, LLC - ISO17025:2017 100033 03/1/2022 MA Massachusetts DEP M-MA100 06/30/2020 CT Connecticut Department of Publilc Health PH-0567 09/30/2021 NY New York State Department of Health 10899 NELAP 04/l/2020 NH-S New Hampshire Environmental Lab 2516 NELAP 02/5/2020 RI Rhode Island Department of Health LA000112 12/30/2020 NC North Carolina Div. of Water Quality 652 12/31/2020 NJ New Jersey DEP MA007 NELAP 06/30/2020 FL Florida Department of Health E871027 NELAP 06/30/2020 VT Vermont Department of Health Lead Laboratory LL015036 07/30/2020 ME State of Maine 2011028 06/9/2021 VA Commonwealth of Virginia 460217 12/14/2020 NH-P New Hampshire Environmental Lab 2557 NELAP 09/6/2020 VT-DW Vermont Department of Health Drinking Water VT-255716 06/12/2020 NC-DW North Carolina Department of Health 25703 07/31/2020 PA Commonwealth of Pennsylvania DEP 68-05812 06/30/2020 11 Table of Co Page 10 of 13 1/18/2020 Track your package or shipment with FedEx Tracking Table of Contents 411359784673 Delivered Saturday 1 /18/2020 at 10.23 am DELIVERED Signed for by. R.PETRAITIS GET STATUS UPDATES OBTAIN PROOF OF DELIVERY Shipment Facts TRACKING NUMBER SERVICE WEIGHT 411259784673 FedEx Priority Overnight 30 Ibs / 13.61 kgs DIMENSIONS DELIVERED TO TOTAL SHIPMENT WEIGHT 2,'x15x13 in. Shipping/Receiving 30 ibs / 13.61 kgs PACKAGING SPECIAL HANDLING SECTION STANDARD TRANSIT YOUr Packaging Saturday Deliverv, Additional Handling 0 Surcharge 1/ 18/2020 by 12:00 pm SHIP DATE ACTUAL DELIVERY O Sat 1/18/202010.23 am Fri 1/17/2020 * 0 Travel History Local Scan Time V Saturday , 111812020 10.23 am Delivered 9.28 am WINDSOR LOCKS, CT On FedEx vehicle for delivery j 8:55am WINDSOR LOCKS, CT At local FedEx facility 7:56 am EAST GRANBY, CT I At destination sort facility 4:57 am MEMPHIS, TN Departed FedEx location Friday,1/1712020 I in-ci — hACLADUIC TAi i Arrfi,n,1 at LorlFv Innofir.n S Page 12 of3htts:/Iwww.fedex.con/aPP$Hedextrackl?trknbr411359784673&trk ual=2458866000-411359784673-FX&Iocale=en_US&cnt ry_code=us t ht[p:; ; wwv .contestlabs.com Doc # 379 Rev 1 03242017 con -test Phone: 413-525-2332 CHAIN OF CUSTODY RECORD (North Carolina) 39 Spruce Street ANAL"AL I.AAOMATow Fax:473-525-6405 East Longmeadow, MA 01028 ;i� - Email: infoocontestlabs.com 7-Day ❑ 10-Day ) Z °+. IVt C 4.(s, �SSr:clte J Due Date c� Address: ticci Phone: (qrq <„*1-Day El3-Day❑ ANALYSIS REQUESTED m. 1e6°,Jc' 1dYl':� uc- 2 Day ❑ 4 Day ❑ Project Location: We lm r c ti, Project Number: (�2�i' i'►. f 0 Format: PDF EXCEL ❑ Project Manager: Con -Test Quote Name/Number: Invoice Recipient: ?ST4 Sampled By: ie_ryes,i 1 Con -Test Work order# L -01/ by: (silature) v a fished by: (signature) O ed by: (signature) w Other: CLP Like Data Pkg Required: .Y��,L rnW�_,nV (ICf,W1 Email To. i`� C Fax Tod: Client Sampie ID / Description : Bmirtning Ending tt 'Aiatrix coin Page ____ of k or Containers z Preservation Code a Container Code ❑ Field Filtered ❑ Lab to Filter Field Filtered Lab to Filter date/Time bate/Time Compos o Grab code Code ' Matrix Codes: GIN = Ground Water +IrS zatc 1,5i2P r ic,ccrlm tip; cc + •� O t WW = Waste Water DW = Drinking Water �it51��� 1t51zP c �t: rrninc>t>Prn C, A =Air S = Soil z J C iI:(tkc»7 I c�,c,,•rt X ( SL =Sludge SOL=Solid ,1151Z�w `ii5lfez, w 0. t t,m *,I"Lt>zy 7X 0 0 = Other (please Date/Time: "iIsime, 7/Time: Z- I r, Date/Time: Date/Time: Date/Time deFlne) z Preservation Codes: I = Iced H=HCL M = Methanol N = Nitric Acid S = Sulfuric Acid B = Sodium Bisulfate X = Sodium Hydroxide T - Sodium Thiosulfate 0 = Other (please Please use the following codes to Indicate possible sample concentration define) within the Coric Code column above: H - High; M - Medium; L - Low; C - Clean; U - Unknown 'Container Codes: A = Amber Glass G = Glass P ' P{'O�'illil Information 2L �' r DSCA❑ UST/Trust Fund Sws Landfill ❑ REC IHSB Orphaned landfill A State Lead Other: P = Plastic ST = Sterile U = Vial S = Summa Canister T = Tedlar Bag 0 = Other (please GWPC SWSL 1HS8 MSCC define) Project Entity ❑ Government ❑ Municipality ❑ Federal ❑ Brownfield ❑ City n School ❑ Chromatogram ❑ AIIfA-LAP,LLC PCB ONLY ❑ Soxhlet ❑ Non Soxhlet v CT (u O_ 0 O O cD C_�_` p ,t 8- � (� httu.: !vvwv .contesUabs.com Doc A 379 Rev 1_0324ZO17 con- to Phone: 413-525-2332 ; 11 CHAIN OF CUSTODY RECORD (North Carolina) 39 Spruce Street Mrncu 7O"r Fax:413-525-6405 East Longmeadow, MA 01028 sY<., ,, .,z Email: info4acontestlabs.com 7-Day ❑ 10•Day tom' j Z Address tjCyq 'ecq, l j, % V; ems.. Phone: (q l9 Zyth6'� Project Location: Project Number: Project Manager: Con -Test Quote Name/Number: Invoice Recipient: Sampled By: Con -Test Work Orders y ad by: (slgjtature) v ished by: (signature) O ed by: (signature) W M C {�}to 4Sc:c�ie j Due Date: Q kw r, 1-Day ❑ 3-Day 2-Day ❑ 4-Day ❑ Jc 19Y1 �t Y CLC T�7 . 0_7iLI-1 f0 Format: PDF'4<L-ff EXCEL ❑ Other: CLP Li k D ANAL Page _ of A of Containers Z Preservation Code ' Container Code �... n ❑ Field Filtered ❑ Lab to Filter e ata Pkg Required. Email To: 7c.nt,rc, ��• Fax To A: i rt Z5 ± `iiSCS c m `— �r LJ Field Filtered ❑ Lab to Filter Client Sample ID I Description Beginning batelTirne Ending Date/Tlrrte dos C tte . Grab xAtatrix Cody, Code Matrix Codes: GW = Ground Water WW = Waste Water DW = Drinking Water A = Air S = Soil SL = Sludge SOL=Solid O= Other (please q i ,ii5 Z�2c i 1 5i2�w C i Y L; C x /i 1 titLSiZ"'Zu t: Kn `1LSIZn4c t t, ct,�,n G✓ n L 2 i+5lzG U l;tr<rrv�fi '1t5 uKti A1f�1Liu61&Z., ,r,ct,t,�,LL vn w x 0 L x Date/Time: iIIe)l &ZO z. tlDa /Time: (,, �1-� Date/Time: Date/Time: define) Preservation Codes: I = Iced H=HCL M = Methanol N = Nitric Acid S = Sulfuric Acid B = Sodium Bisulfate X = Sodium Hydroxide T = Sodium Thiosulfate 0 = Other (please Please use the following codes to indicate possible sample concentration define) within the Cone Code column above: H - High; M - Medium; L - Low; C - Clean: U - Unknown 3Container Codes: A = Amber Glass Program Information G = Glass LJ 2L DSCA ❑ UST/Trust Fund P = Plastic GWPC SWS Landfill ❑ REC = Sterile SWSL V V =Vial IHSB Orphaned Landfill S = Summa Canister IHSB State Lead T = Tedlar Bag ❑ MSCC Other: 0 = Other (please define) roject Entity Other ❑ Government ❑ Municipality ❑ Chromatogram ❑ Federal ❑ Brownfield ❑ AIHA-LAP,LLC ❑ City n School PCB ONLY Soxhlpt ❑ Non Soxhiet W (T m O_ 0 O 7 m rn