Loading...
HomeMy WebLinkAboutSW6120401_Add Info Request/Response to Comments_20120417ARE� AN = NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perr_lue Governor Mr. Scott Brown, PE 4D Site Solutions 409 Chicago Dr., Ste. 112 Fayetteville, NC 28306 Dear Mr. Brown: Charles Wakilrl, P.E. Director April 17, 2012 Subject: Request for Additional Information Stormwater Project No. SW6120401 Cumberland Park Hoke County Dee Freeman Secretary The Division of Water Quality Central•Office received a Stormwater Management Permit Application for the subject project on April 10,'201.2. A,preliminary review of that information has determined that the application is not complete. The following information is needed to continue the stormwater review: 1. Please provide information about lot 11. This lot must be accounted for in the Deed Restrictions Form, The ultimate build -out must be shown and accounted for in the application. As it is shown now, it would receive a zero BUA allotment; and any future BUA on that lot would require treatment and a permit modification request. 2. The allotted lot BUA shown on the Deed Restrictions Form is not consistent with the BUA listed in IV.10. of SWU-101. 3. Pretreatment and energy dissipation should be provided at the pipe outlets into the infiltration basin. 4. Velocity calculations need to be provided for the v-swales to determine if energy dissipation is needed at their outlets into the infiltration basin. 5. Plan sheets C-3.0 and C-3.1: The infiltration basin note shows the emergency spillway at el. 249,65', but the spillway note just above the basin note shows it at el. 248.60'. Please make consistent. Based on the calculations it should be at el. 249.65'. 6. The calculations show the minimum treatment volume as 4,887 cf, but the supplement shows only 2,535 cf. The Basin Design Parameters and Basin Bottom Dimensions on the supplement form are consistent with the calculations and plans. Please verify that all are shown consistently throughout. Please note that this request for additional information is in response to a preliminary review. The requested information should be received by this Office prior to May 16, 2012, or the application will be Wetlands and Stormwater Branch 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Location: 512 N. Salisbury St. Raleigh, North Carolina 27604 Phone: 919-807-63001 FAX: 91 M07-6494 Internet: www.ncwaterquality.org An Equal Opportunily 1 Affirmative Action Employer Nne orthCarolina naturally Mr. Scott Brown, PE SW6120401 —Cumberland Park April 17, 2012 returned as incomplete. The return of a project will necessitate resubmittal of all required items, including the application fee. If you need additional time to submit the information, please mail or fax your request for a time extension to the Division at the address and fax number at the bottom of this letter. The request must indicate the date by which you expect to submit the required information. The Division is allowed 90 days from the receipt of a completed application to issue the permit. The construction of any impervious surfaces, other than a construction entrance under an approved Sedimentation Erosion Control Plan, is a violation of NCGS 143-215.1 and is subject to enforcement action pursuant to NCGS 143-215.6A. All revised original signed documents must be returned or new originals must be provided, Copies are not acceptable. Any revised calculations or plans must be sealed, signed, and dated; and have a revision date shown. Please reference the State assigned project number SW6120401 on all correspondence. If you have any questions concerning this matter please feel free to call me at (919) 807-6375, or at robert.patterson@ncdenr.gov. Sincerely, G2G4? `Y e Robert D, Patterson, PE Environmental Engineer Stormwater Permitting Unit cc: SW6120401 File ec: Lorraine Mohler Mike Lawyer — Fayetteville Regional Office Scott Brown, PE — 4D Site Solutions Page 2 of 2 4c),51TF ® 50LUTION,5, INC. �tJGIOr RiN� LAND SurzVLYiN4 CON .')TZUCTION LAYOUT ( P.S _SLP_VICLS LAND DEVLLOPt�G-NT nog CLIICAGO 9 ZIVV_ 5LITIL H2 FAYLTTLVILLL NG 28506 PLONK 910 626-6777 FAX 9i0 426-5777 April 17, 2012 NCDENIZ [land Quality Section Attn: Robert Patterson, PE 225 Green Street, Suite 714 Fayetteville, NC 28301 RE: Storm Water Plan Submittal, Cumberland Park, Raeford, North Carolina Robert; We are re -submitting the Phase 11 Storm Water permitting package f-or Cumberland Park with the additional requested information. Please find enclosed 2 copies of the revised construction sheets, revised application page 4, supplement form and additional information. 1. Lot 1 I is to be left with a zero BUA, and the permit will need to be modified in the future if that property is ever developed. 2. The BUA for the lots now match -up between the Deed Restrictions and the SWU-101 application. 3. Rip rap energy dissipaters have been added at the outlets of each pipe into the basin. The pipe outlet with the greatest velocity was used to calculate the rip rap dissipater size so the others are slightly over designed. 4. Velocity calculations for the swales have been provided, and the flows do not require the use of any type of energy dissipaters at the outlet of the swale. 5. Plan sheets C-3.0 & C-3.1 have been revised, and two copies are included in this submittal. E. The supplement form has been revised to show the 4,887 cf�of treatment volume. 7. All the basin design parameters are consistent throughout the plan sheets. I look forward to working with you on this project. 1 f you have any questions or concerns, please feel free to contact us. Sincerely, D Site Solutions Inc. Scott 3rown Protessional Engineer F111CIOsure D APR 192012 DENR - Wi47ER QUAL TV