Loading...
HomeMy WebLinkAboutNCS000589_MONITORING INFO_20191028Plw STORMWATER DIVISION CODING SHEET NCS PERMITS PERMIT NO. I" DOC TYPE ❑FINAL PERMIT ')q, MONITORING REPORTS 0 APPLICATION ❑ COMPLIANCE ❑ OTHER DOC DATE ❑ YYYYMMDD f DUKE ENERGY® PROGRESS October 25, 2019 Certified Mail # 7518 1130 6001 4419 9252 (2 copies) NC DECK—DW R, Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 OCT 2 8 zo�� BEN-NALDVVR'SECFf Subject: Weatherspoon's September 2019 Stormwater Discharge Monitoring Report (DMR) Submittal Dear Sir or Madam: W. H. Weatherspoon Plant 491 Power Plant Rd Lumberton, NC 28358 Mailing Address: Kent Tyndall L. V. Sutton Energy Complex 801 Sutton Steam Plant Rd Wilmington, NC 28401 o: 910.341.4775 Duke Energy Progress, LLC submits in duplicate the Stormwater Discharge Monitoring Report for W. H. Weatherspoon. This submission is made in accordance with Part III, Section E of our NPDES Stormwater Permit No. NCS000589. SW-2 is in Tier I status due to 12/14/2018 TSS sampling result being above the benchmark value. Therefore, we are required to conduct monthly monitoring at this outfall until three consecutive sample results are below the benchmark values or within benchmark range. Neither SW-1, SW-2, or SW-3 had a discharge in September 2019. The attached table list each day during the month that had rainfall. It also explains why sampling was not performed on those days. If there are any questions, please contact either: • Mr. Kent Tyndall, EHS Professional for the W. H. Weatherspoon Plant; phone (910) 341-4775 or e-mail Kent:Tyndall@duke-energV.com; or • Ms. Joyce Dishmon, Environmental Specialist with our Environmental Permitting and Compliance Group, phone (336) 623-0238 or email JoVce.Dishmon@duke-eneray.com. Please direct all correspondence to Kent Tyndall via the mailing address shown above. 1 certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. 1 am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Sincerely, Jeffrey Flanagan Station Manager Weatherspoon's September 2019 Stormwater Discharge Monitoring Report (DMR) Submittal Table Page 1 of 1 Date of rainfall,= ' ;Y. 'Actual n, ,'stormwater'..-41` ischarge? �72-hrs since last ,'; discharge? ". Can'sarnpie` -miriufes . Safe:to Can wli:nor'mal� `_ business sample' hrs? / + . STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT Permit Number NCS000589 FACILITY NAME W. H. Weatherspoon Plant PERSON COLLECTING SAMPLE(S) Kent Tyndall CERTIFIED LABORATORY(S$healy Environmental Services. Inc. Lab # 329 Duke Power Company LLC d/b/a Duke Energy Carolinas, [,LC Lab # 248 Duke Energy Progress -Sutton Steam Electric Plant Lab # 5056 Part A: Specific Monitoring Requirements Sepiemher SAMPLES COLLECTED DURING CALENDAR YEAR: 2019 (This monitoring report shall he received by the Division no later than 34) days from the date the facility receives the sampling results from the labotatory.) COUNTY PHONE NO. Robeson Kent Tyndall, o: 910-341-4775 SIGNATURE OF PERMITTEE OR DESIGNEE REQUIRED ON PAGE 2. Outfall No. Date Sample Collected 50050 00400 - 00530 01097 Total Flow (if app.) Total Rainfall - pH Precip pH (if taken) TSS Nan -Polar. Oil & Grease Antimony (Sb) mo/dd/yr MG inches Units Units mg/L mg/L mg/L SW-1 No Flow SW-2 No Flow SW-3 No Flow Benchmark Value 6-9; (IF precip pH is lower, THEN lower threshold is precip pl-1.) , 100 l5 0.09 Outfall 01002 01012 01027 01034 01042 01051 71900 01067 01147 No. Arsenic . (As) Beryllium (Be) Cadmium (Cd) Chromium (Cr) Copper (Cu) Lead (Pb) Mercury (Hg) Nickel (Ni) Selenium (Se) mg/L mg/L mg/L mg/L mg/L mg/L ng/L; mg/L mg/L SW -I SW-2 SW-3 Benchmark Value 0.34 0.065 0.003 0.9 0.0i 0.075 12 0.335 0.056 Outfall No. 01077 01092 01022 01059 Silver (Ag) Zinc (Zn) Boron (B) Thalliium (TI) mg/L mg/L mg/L mg1L SW- I SW-2 SW-3 Benchmark Value 0.0003 0.126 - - - Form SWU-247, last revised 21212012 Page I of 2 Facility Name W, H. Weatherspoon Plant Permit Number NCS000589 Does this facility perform Vehicle Maintenance Activities using more than 55 gallons of new motor oil per month? (if yes, complete Part 13) Part 13: Vehicle Maintenance Activity Monitoring Requirements No Outfall No. Date Sample Collected 50050 00556 00530 00400 Total Flow (if applicable) Total Rainfall Oil & Grease (if appl.) Non -polar O&G/TPH (Method 1664 SGT-HEM), if appl. Total . Suspended Solids pH New Motor Oil Usage mo/dd/yr MG inches mg/L mg/L unit gal/mo STORM EVENT CHARACTERISTICS: Mail Original and one copy to: Division of Water Quality Date Attn: Central Files Total Event Precipitation (inches) 1617 Mail Service Center Event Duration (hours) (only if applicatle - see permit.) Raleigh, North Carolina 27699-1617 (if more than one storm event was sampled) Date Total Event Precipitation (inches) Event Duration (hours) (only if applicatle - see permit.) "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathereing the information, the information submitted is, to the best of my knowledge and belief , true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." Jeffrey Flanagan (Signature of Permittee) -/ 0�/mil (Date) Form SWU-247, last revised 21212012 Page 2 of 2 DUKE ENERGY® PROGRESS September 25, 2019 -,s D Certified Mail # 7018 1130 6001449 0160 (2 copies) 0 C T 2 8 2019 NC DEQ—DWR, Central Files 1617 Mail Service Center CENTRAL F1LFS Raleigh, North Carolina 27699-1617 DWR SECTION Subject: Weatherspoon's August 2019 Stormwater Discharge Monitoring Report (DMR) Submittal Dear Sir or Madam: W. H. Weatherspoon Plant 491 Power Plant Rd Lumberton, NC 28358 Mailing Address: Kent Tyndall L. V. Sutton Energy Complex 801 Sutton Steam Plant Rd Wilmington, NC 28401 o:910,341.4775 Duke Energy Progress, LLC submits in duplicate the Stormwater Discharge Monitoring Report for W. H. Weatherspoon. This submission is made in accordance with Part ill, Section E of our NPDES Stormwater Permit No. NCS000589. SW-2 is in Tier I status due to 12/14/2018 TSS sampling result being above the benchmark value. Therefore, we are required to conduct monthly monitoring at this outfall until three consecutive sample results are below the benchmark values or within benchmark range. Neither SW-1, SW-2, or SW-3 had a discharge in August 2019. The attached table list each day during the month that had rainfall. It also explains why sampling was not performed on those days. If there are any questions, please contact either: • Mr. Kent Tyndall, EHS Professional for the W. H. Weatherspoon Plant; phone (910) 341-4775 or e-mail Kent.Tyndall@duke-energy.com; or • Ms. Joyce Dishmon, Environmental Specialist with our Environmental Permitting and Compliance Group, phone (336) 623-0238 or email J_oyce.Dishmon@duke-energy.com. Please direct all correspondence to Kent Tyndall via the mailing address shown above. 1 certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. 1 am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Sincerely Jeffrey Flanagan Station Manager Weatherspoon's August 2019 Stormwater Discharge Monitoring Report (DMR) Submittal Table Page 1 of 1 Date of, {' rainfall 0• ,,,Actual.i r ' stormavater `�', ,'.discharge? _.>72-hrs since - .:; ,•last. .• `.,,wli discharge? Can sample : first,30- " minutes? ` FSafe to ,sample?.r ' 'Can sample '; ,`r•; wli normal business hrs?. 0• 0• f • • 0• 0• 0• 0• M ..... . . . . . . ..... ..... . . . . . . . . - 5TORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT Permit Number NCS000589 FACILITY NAME tip . H. Weatherspoon Plant PERSON COLLECTING SAMPLE(S) Kent'ryndall CERTIFIED LABORATORV(S$hcaly Environmental Services. Inc. Lab # 329 Duke Power Company LI.0 d/b/a Duke Energy Carolinas. LLC Lab # 248 Duke Energy Progress -Sutton Steam Electric Plant Lab # 5056 Part A: Specific Monitoring Requirements August SAMPLES COLLECTED DURING CALENDAR YEAR: 2019 (This monitoring report shall be received by the Division no later than 30 days from the date the facility receives the sampling results from the labotatory.) COUNTY Robeson PHONE NO. Kent Tyndall, u: 910-341-4775 SIGNATURE OF PERAH'ITEE OR DESIGNEE REQUIRF.D ON PAGE 2. Outfall No. Date Sample Collected 50050 00400 00530 01097 Total Flow (if app.) Total Rainfall pH Precip pH (if taken) TSS Non -Polar Oil & Grease Antimony (Sb) mo/dd/yr MG inches Units Units mg/L mg/L mg/L SW-1 No Flow SW-2 No Flow SW-3 No Flow Benchmark Value 6-9; (IF precip pH is lower, THEN lower threshold is precip pH.) 100 15 0.09 Outfall No. 01002 01012 01027 01034 01042 01051 71900 01067 01147 Arsenic (As) Beryllium (Be) Cadmium (Cd) Chromium (Cr) Copper (Cu) Lead (Ph) Mercury (Hg) Nickel (Ni) Selenium (Se) mg/L mg/L mg/L mg/L mg/L mg/L ng/L mg/1, mg/L SW-1 SW-2 SW-3 Benchmark Value 0.34 0.065 0.003 0.9 0.01 0.075 12 0.335 0.056 Outfall No. 01077 01092 01022 01059 Silver (Ag) Zinc (Zn) Boron (B) Thalliium (TI) mgf L mg/L mg/L mg/L SW-1 SW-2 SW-3 Benchmark Value 0.0003 0.126 - • - - - Form S W U-247, last revised 2212012 .A Page I of 2 Facility Name W. H. Weathersnoon Plant Permit Number NCS000589 Does this facility perform Vehicle Maintenance Activities using more than 55 gallons of new motor oil per month? (if yes, complete Part B) Part B: Vehicle Maintenance Activity Monitoring Requirements No Outfall No. Date Sample Collected 50050 00556 00530 00406 Total Flow (if applicable) Total Rainfall Oil & Grease (if appl.) Non -polar O&G/TPH (Method 1664 SGT-HEM), if appl• ` Total Suspended Solids pH New Motor Oil Usage mo/dd/yr MG inches mg/L mg/L unit gal/mo STORM EVENT CHARACTERISTICS: Mail Original and one copy to: Division of Water Quality Date Attn: Central Files Total Event Precipitation (inches) 1617 Mail Service Center Event Duration (hours) (only if applicatle - sec permit.) Ralcigh, North Carolina 27699-1617 (if more than one storm event was sampled) Date Total Event Precipitation (inches) Event Duration (hours) (only if applicatle - sec permit.) "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathereing the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." September 25, 2019 (Date) Form S W U-247, last revised 21212012 Page 2 of 2